Powers Controls ET 134 Low Temperature Detection Thermostat

Similar documents
Powers Controls Low Temperature Detection Thermostat

Technical Instructions Document No P25 ET September 28, ET 141 Electric Surface Mounted Thermostat.

Powers TM Controls ET 134 Line Voltage Room Thermostats

Technical Instructions Document No P25 ET September 28, ET 141 High Limit Control Thermostat. Description.

TC-5231 Series, TC-5232, & TC-5241 Series

PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE

Thermostat KPU. Data sheet

Thermostats type KPU REFRIGERATION AND AIR CONDITIONING. Technical leaflet

RAB10 Series Two-pipe Fan Coil Room Thermostat with Manual Changeover

The T6140A,B Remote Bulb Temperature Controller

A11 Series Low Temperature Cutout Controls

QVE1901U Flow Switch. Technical Instructions Document No September 20, Description. Features. Application.

TK-2001, TK-2012, TK-2201, TK-3001, TK-3201, TK-4001, TK-4012, TK-4212 TK

FS80-C Flow Switch. Features and Benefits. Allows user select the setting according the needs of system

Aquastats. Aquatrol Indoor/Outdoor Control. Automatic Changeover Switch 16/05/08

Powers TM Controls TH 188 Unit Mounted Thermostat

T4031A,B,P; T6031A,B Refrigeration Temperature Controllers

AS570 Chill-Out Combination Sensor Installation and Operating Instructions

Brasch Hazardous Location Unit Heaters

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

Tubular Industrial Process

59T, 66T Series Electric Water Heater Controls

59T, 66T Series Electric Water Heater Controls

MR3CCUHV Temperature/Defrost Control

Q-Series Relative Humidity and Relative Humidity & Temperature Sensors for Critical Environments and Outdoor Air

Two-Position Electric Duplex Room Thermostats

A19, A28 Series Thermostats for Agricultural Buildings

MR4PMUHV Electronic. Temperature/Defrost Control with Relay Pack

Tubular Industrial Process

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

y Small dimensions. Easy to install in refrigerated counters or cold rooms

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

W43A Humidistat. Features and Benefits

temperature Controllers

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-214(C) Series 61 Low Water Cut-Off OPERATION

Description. Applications

KUH. Horizontal Unit Heater. Applications. Description

Pipe Thread Heaters. Construction Features. 1" 2-1/2" Pipe Thread Heaters

MS4PMUHVT Multi-Stage Electronic Temperature Control with Relay Pack

Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s)

ULTRA-SAFE Explosion-proof Duct Heaters

System 350 S350A Temperature, S351A Humidity, and S352A Pressure Stage Modules

Description. Construction

SEALED ENCLOSURE COOLING

Chromalox Electric Airduct Heaters with Fintube Heating Elements. Conduit Entrance Plate. DHRF Remote Controls Flanged Type Figure 4

WATLOW ELECTRIC MFG CO. WATROD Duct Heater (module only) I& M Manual I&M NUMBER: Page: 1 Date: 11/25/2013 Rev: 4.00

INDEX APPLIANCE GAS WATER HEATER CONTROLS 150 ELECTRIC WATER HEATER THERMOSTATS 151 SNAP DISC CONTROLS/LIMITS/SWITCHES 152 GAS DRYER VALVES 153

WATLOW IND. WATROD Modular Duct Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2

Series 47 and 247 Mechanical Water Feeders. Series 47-2 and Combination Mechanical Water Feeder/Low Water Cut-Off ! WARNING

ELECTRIC SPA-PAK HEATER INSTALLATION & OPERATING INSTRUCTIONS

SUBMITTAL SCHEDULE & DATA

T4398A,B Precision Electric Heating Thermostat

INSTALLATION INSTRUCTIONS FOR 8330*5511 MOUNTING KIT

Comfort. Description. Applications

INSTALLATION INSTRUCTIONS

ULTRA-SAFE Explosion-proof Duct Heaters

Operator: Save these instructions for future use!

Operator: Save these instructions for future use!

( )

(770) wwww.southgateprocess.com

Capillary & Bulb Thermostatic Control & Fail-Safe Limit

ACT-HSC Series Heat Sink Coolers Sealed Enclosure Cooling Installation Guide

POWERS TM Controls HU 186 Room And Duct Hygrostats

Series 1140 and 1141 Temperature Regulators

Powers TM Controls Accessories for Installing TH 192, TH 194 or Free Energy Band TH 193 HC Room Thermostats

HLA Series Hazardous Location Fan Forced Unit Heater

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

HLA Series Hazardous Location Fan Forced Unit Heater

Chromalox. Installation, Operation. Screw Plug Heating Solution Control Panel Assembly for Screw Plug Heaters RENEWAL PARTS IDENTIFICATION

! WARNING. Before using product, read and understand instructions.

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side

Pipe Thread Heaters. Construction Features. Star Electric to Order Call " 2-1/2" Pipe Thread Heaters

Location Requirements

INSTALLATION INSTRUCTIONS

E U R O V E N T CERTIFIED PERFORMANCE

LIFTAIRE II ELEVATOR AIR CONDITIONER

MODEL GPT-130 SINGLE POINT HEAT TRACE CONTROL THERMOSTAT

Operator: Save these instructions for future use!

CFF-500 CHILLER. Operator s & Installation Manual. Release Date: November 3, 1996 Publication Number: Revision Date: March 25, 2014 Revision: F

Macurco CM-21A Carbon Monoxide

EXH Series Explosionproof Electric Air Heaters

Table of Contents. Protective Relays

Refer to the Page 23 (inside back cover) for Model Nomenclature. Table of Contents

Thermostat RT. Data sheet

FX5 Series Explosion-Proof Electric Air Heaters

Temperature, Mechanical

INSTALLATION INSTRUCTIONS FOR 6797A737 HEAT PUMP FLUSH MOUNT CEILING PLENUM

SECTION METERS AND GAGES FOR HVAC PIPING

UHIR Series. Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater. Owner s Manual

Operator: Save these instructions for future use!

TEMPERATURE & PRESSURE CONTROLS

Installation Instructions 30 French Door Built-in Wall Ovens

Schneider Electric Erie T155 Series

L Honeywell. L4068 has spst switch; L6068 has spdt switch. L4068A,C,E,F have adjustable FAN OFF and differential settings.

4TTB3030D1000B 208/230/1/60 4TTB3036D1000B 208/230/1/ RECIP /230/1/ RECIP YES YES

208/230/1/ CLIMATUFF /230/1/ YES NO NO PROPELLER 23-1 DIRECT / /230/1/ SPINE FIN

Chromalox. Installation, Operation. Portable Industrial Unit Blower Air Heater Types SDRA and SDRA-RG RENEWAL PARTS IDENTIFICATION

Thermostat Catalog 2004

ProRadiant Controls, Valves and Actuators

Toll-Free: TPI CORPORATION Hazardous Location Fan Forced Unit Heater

Transcription:

Document No. 155-115P25 ET 134-20 Powers Controls ET 134 Low Temperature Detection Thermostat Description Features Product Numbers The Electric Low Temperature Detection Thermostat is a remote bulb instrument with a Single-Pole Double-Throw (SPDT) switch which closes and opens a circuit in both directions. Compact and sturdy Adjustable range with fixed differential Unaffected by ambient temperature at case Manual or automatic reset available The set point adjustment screw is accessible at the bottom of the control or at the top with the cover removed Mounting bracket standard Description Low Temperature Detection Thermostat Automatic reset Product Numbers 134-1510 Manual reset 134-1511 Warning/Caution Notations WARNING: CAUTION: Personal injury/loss of life may occur if a procedure is not performed as specified. Equipment damage, or loss of data may occur if the user does not follow a procedure as specified

ET 134 Low Temperature Detection Thermostat Application The electric low temperature detection thermostats are especially suited for sensing low temperature conditions to avoid freeze-up of hydronic heating coils, cooling coils, liquid heating pipes and similar applications. Typically, the switch opens an electrical circuit to stop the supply fan motor when the temperature at the sensing element falls below the setting of the instrument. WARNING: Specifications Operation The low temperature detection thermostat is designed for use only as an operating control. Where an operating control failure would result in personal injury and/or loss of property, it is the responsibility of the installer to add devices (safety, limit controls) or systems (alarm, supervisory systems) that protect against, or warn of control failure. Switch action SPDT Range 35 to 45 F (2 to 7 C) Maximum bulb temperature 250 F (121 C) Ambient temperature at thermostat 0 to 140 F (-18 to 60 C) Differential 134-1510 12 F (6.7 C) 134-1511 Temperature must be 12 F (6.7 C) above cutout point before control can be reset Bulb 1/8-inch (3.2 mm) x 20 feet (6 m) Capillary length 4 feet (1.2 m) Sensing element Vapor filled Reset type See Product Number Electrical ratings See Table 1 Material Case 0.62-inch (1.57 mm) cold rolled steel Cover 0.32-inch (0.81 mm) cold rolled steel Conduit opening 7/8-inch (22 mm) for 1/2-inch conduit Finish Gray enamel Weight 1.8 lbs. (0.8 kg) Dimensions See Figure 4 Approvals UL file SA3863 CSA File LR948 Any 1-foot length of the element subjected to temperatures below the temperature setting of the thermostat wall actuate the thermostat switch mechanism regardless of the temperature being sensed by the remainder of the element. The sensing element is unaffected by the ambient temperature at the thermostat if it is warmer than the set point temperature. The 134-1511 thermostat has a manual reset feature. (See Figure 5.) NOTE: The reset lever must be pressed manually and released to resume normal fan system operation. Page 2

ET 134 Low Temperature Detection Thermostat Technical Instructions Operation, Continued Table 1. Electrical Ratings. Motor Ratings 120 V 208 V 240 V A.C. Full Load Amps 16 9.2 8 A.C. Locked Rotor Amps 96 55.2 48 Non-inductive Amps 16 9.2 8 Pilot Duty -- 125 VA 24 to 277 Vac Mounting and Installation General Guidelines Large Walk-in Ducts (Figure 1) Locate the sensing element in the downstream side of the coil. Locate the case and bellows where the ambient temperature is always warmer than the set point. Install the thermostat case so that the reset button is readily accessible and the element bellows point down. Avoid sharp bends or kinks in the sensing element. Install as much of the bulb as possible in a horizontal plane. If too much of the bulb is vertical, it will not operate properly. 1. Attach the mounting bracket to the thermostat case with the two round head screws provided. 2. Mount the two perforated steel strap hangers inside the duct with the wide part of the hanger strap parallel to the air flow. 3. Drill a hole through the side of the duct. With the bulb still coiled, thread the bulb through the hole using a rotary movement. 4. Mount the thermostat case on the outside of the duct. 5. Carefully uncoil the bulb avoiding sharp bends or kinks in the sensing element. 6. Mount the bulb in a horizontal serpentine manner. Attaching the bulb to the strap as shown in the detail in Figure 1. The installation is now complete. For an alternate method of mounting, use coil clips (part number 356-115) in the fins to hold the bulb in a horizontal serpentine pattern. Figure 1. Typical Mounting in Walk-in Duct. Page 3

ET 134 Low Temperature Detection Thermostat Mounting and Installation, continued Limited Access Ducts (Figure 2) 1. Attach the mounting bracket to the thermostat case with the two round head screws provided. 2. Attach a mounting flange (part number 808-412) on the opposite side of the duct (near the bottom) from where the thermostat will be mounted. 3. Mount a second flange on a 8-inch by 4-inch sheet metal plate. Cut an access opening for the bulb on the duct diagonally across from the duct mounted flange. Drill mounting screw holes for the sheet metal plate. 4. Cut a length of copper tubing to fit diagonally across the duct. Stretch out the bulb and wrap it around the tubing. 5. Insert the tubing and bulb through the access hole and into the duct-mounted flange. Fasten the 8-inch by 4-inch sheet metal plate to the duct. 6. Mount the thermostat case on the outside of the duct. The installation is now complete. Figure 2. Bulb Mounting for Limited Access Ducts with Mounting Flange. Page 4

ET 134 Low Temperature Detection Thermostat Technical Instructions Wiring WARNING: Disconnect the power supply before wiring connections are made to avoid possible electrical shock or damage to the equipment. All wiring should conform to the National Electrical Code and local regulations. Loads exceeding the rating of the thermostat should be handled by means of a relay or motor starter. Red is common. See Figure 3 for terminal identification. Red to Yellow opens on temp. decrease below set point. Red to Blue closes on temp. decrease below set point. Red to Blue closes on temp. decrease below set point. Red to Yellow opens on temp. decrease below set point. CAUTION: Figure 3. Terminal Identification. Use terminal screws furnished (#8-32 x 1/4-inch binder head screw). Substitution of other screws can cause problems in making proper connections. Dimensions Figure 4. Dimensions of the 134-1510 and 134-1511 Thermostat. Page 5

ET 134 Low Temperature Detection Thermostat Adjustment Change the set point by turning the adjusting screw until the pointer is opposite the desired cutout point. The adjusting screw is accessible at the bottom of the thermostat or at the top when the cover is removed. See Figure 5 for the location of the adjusting screw. The direct reading scale was calibrated at 800 feet (244 m) above sea level at 35 F (2 C). For critical installations in higher altitudes raise the set point by 1 F (0.56 C) for each 1,800 feet (549 m) of elevation. Figure 5. Internal View of Thermostat. Troubleshooting Service Observe a complete operating cycle to be sure that all components function correctly. There is no servicing of the thermostat. Replace if inoperative. Information in this publication is based on current specifications. The company reserves the right to make changes in specifications and models as design improvements are introduced. Powers is a trademark of 2000 Landis & Staefa Division 1000 Deerfield Parkway Buffalo Grove, IL 60089-4513 U.S.A. Document No. 155-115P25 Printed in the U.S.A. Page 6