Selecting the Right Washer-Extractor for Turnout Gear Care

Similar documents
GEAR LAUNDERING ExpressWash. gear washers and dryers designed specifically for fire departments

GIRBAU HIGH-PERFORMANCE HARD-MOUNT WASHER-EXTRACTORS FOR ON-PREMISE LAUNDRIES RMG033 RMG040 RMG055 RMG070 OPL WASHER-EXTRACTORS

GIRBAU ON-PREMISE LAUNDRY HIGH-PERFORMANCE SOFT-MOUNT WASHER-EXTRACTORS EH030 EH040 EH060 EH080

PREPARE, PROTECT & PREVENT: THE GUIDE TO PROPER PPE CLEANING

EH020 EH030 EH040 EH055 E-SERIES HIGH-PERFORMANCE WASHER-EXTRACTORS FOR VENDED LAUNDRIES

EH020 EH030 EH040 EH055 EH090. ExpressWash HIGH-PERFORMANCE WASHER-EXTRACTORS FOR VENDED LAUNDRIES

GIRBAU HIGH-PERFORMANCE HARD-MOUNT WASHER-EXTRACTORS FOR VENDED LAUNDRIES RMG033 RMG040 RMG055 RMG070 VENDED WASHER-EXTRACTORS

A MORE EFFECTIVE CLEANING SYSTEM FOR YOUR PERSONAL PROTECTIVE ENSEMBLES

LG PLATINUM COMMERCIAL LAUNDRY SYSTEMS. Washers & Dryers for On-Premise Laundries

EXPRESSWASH HIGH-PERFORMANCE WASHER-EXTRACTORS FOR VENDED LAUNDRIES GIRBAU EH020 EH030 EH040 EH060 EH090

Premier Microprocessor (PM) Control Peak Efficiency and Productivity. No Sump Design Decreased Water Consumption

Premier Microprocessor (PM) Control Peak Efficiency and Productivity. No Sump Design Decreased Water Consumption

TRAINING AND EQUIPMENT MANUAL 311 PERSONAL PROTECTIVE EQUIPMENT FIREFIGHTER PROTECTIVE CLOTHING CLEANING PROCEDURES EFFECTIVE: OCTOBER 2007

LG PLATINUM COMMERCIAL LAUNDRY SYSTEMS. Card- & Coin-Operated Commercial Washers & Dryers for Vended Laundries

FIRE FIGHTER LAUNDRY PLANNING FILE

experience the advantage high-speed equipment unique store services management training marketing support

GIRBAU DRYING TUMBLERS FOR ON-PREMISE LAUNDRIES CG20-30 CG30-40 CG55-65 CG50-60 CG75-85 CG CG CG

engineered for a higher return

PROTECT YOUR DEPARTMENT WITH CLEANER GEAR AND THE RECORDS TO BACK IT UP FIRELINC TM TECHNOLOGY OVERVIEW

IAFF DIVISION OF OCCUPATIONAL HEALTH, SAFETY AND MEDICINE

Fire Service Contamination Control Research

Soiled garments reflect less radiant heat. Materials saturated with hydrocarbons will absorb not deflect radiant heat from a fire.

TURNOUT GEAR DRYERS. 4-Unit Turnout Gear Dryer with Touchscreen Control Four Drying Units; 4 Helmet Dryers;12 Accessory Ports

On-Premises. A Passion to Lead

Electrolux Professional Line 5000 The all-in-one business solution for your Self-Service Laundry

Contamination Control Campaign Workshop Introduction and Overview

A. Product data. Unless otherwise indicated, submit the following for each type of product provided under work of this Section:

FOR ON-PREMISES LAUNDRY

PPE Care. Care and Maintenance program for Morning Pride TAILS VIPER and RANGER Structural Gear

LAUNDRY SOLUTIONS FOR HOSPITALITY LAUNDRIES. laundry systems designed specifically for all segments of the hospitality industry

ENERGY STAR Program Requirements Product Specification for Commercial Water Heaters. Eligibility Criteria Version 1.0: Draft 1

Maytag Commercial Laundry Industrial Washers. Dependable engineering to tackle even the most demanding applications.

SAN LUIS OBISPO CITY FIRE. Inspection and Maintenance of Protective Clothing. Use of PPE

8/2017. Firefighter protective clothing ANACONDA. 3rd category of Personal Protective Clothing

ASPIRE Laboratory Aspirator

COIN OPERATED ELECTRONIC QUANTUM GOLD WASHERS

SPOTLIGHT ON WATER CONSERVATION

Care Home Laundry Construction Guide. Supporting architects, developers and builders Every step of the way. Laundry equipment

SUPPORTING ARCHITECTS, DEVELOPERS AND BUILDERS EVERY STEP OF THE WAY

New Jersey Fire Department Overcomes Site Issues, Contaminated Soil, and High Water Table to Build New Fire Headquarters Station

INDUSTRIAL LAUNDRY EQUIPMENT FOR VENDED LAUNDRY APPLICATIONS. Washer-extractors I Tumble Dryers Flatwork Ironers I Semi-Commercial Equipment

Very Important Purchase Information

PPE And The Law by Jim Juneau: Juneau, Boll, Stacy & Ucherek, PLLC, Dallas, TX

EXHIBIT 1. California Home Energy Savings Program Measures, Incentives, and Qualifications

TFCA Best Practices: Ch.11. ROFR Section: PERSONAL PROTECTIVE EQUIPMENT PROTECTIVE CLOTHING. Effective: 3/2013.

Take a closer look at the coin laundry business

Energy Efficiency Business Rebates Natural Gas Catalog

MANUAL CONTROL COMPACT COMMERCIAL

LLT wash system simplifies workflow, boosts efficiency for Detroit hospital co-op laundry.

GUH90 90 cm Canopy Hood

Technology Menu Hospitality Laundry

What s new in perfection?

Developing Your Carpet Maintenance Plan

EQUIPMENT YOU CAN DEPEND ON ON-PREMISES FULL LINE CATALOG

fact fact fact result No quibble, 7 year warranty. No strings attached. No fans going to landfill sites Happy tenants Money saved

Firefighter protective clothing GEPARD

GUH52SD 52 cm GUH75 75 cm Canopy Hood

Changing Carpet Care Forever

Traditional Coin-Operated

Polk County Fire Rescue Turnout Gear and Ensemble Elements

All Types - Automatic, semi-automatic and manual. All Types - Horizontal (front loaders) and Vertical Plane (top loader)

CONTINUOUS BATCH WASHING SYSTEMS. unrivaled productivity, efficiency and cleaning flexibility for laundries with medium- to large-volume needs

Economic Impact of Building Regulations

Line 5000 offers real benefits and improvements in three crucial areas for professional clients: durability, enhanced economy and flexibility.

Where There's Smoke. Warrant Article 4 - New Fire Station

COMPENSATORY EFFECTY OF FIXED FIRE FIGHTING SYSTEMS IN TUNNELS

New levels of reliability for hydraulic systems

Fit speed and style just about anywhere " Compact Laundry Brochure

GAS DISTRIBUTION PRODUCTS PA MECHANICAL SADDLES & FITTINGS

Drying Cabinet. ProLine FC 20 - for Protective Garments. PODAB - Professional Laundry Products

Operating Instructions

Ingersoll Rand 5-15 hp. Rotary Screw Compressors

ThwarTing MrS ection in The wash

SMOOTHFLOW 130 LB. Automated Batch Tunnel Washing System. ISO 9001 Certified. gabraun.com. All Braun Products are Proudly Manufactured in the U.S.A.

Presenter: Malcolm McLaughlin Date: 04/04/2019. A Review of Medical Device and Optical Critical Cleaning

WEBs-AX. Endless Possibilities For Building Control, Management And Savings

ON VERY RARE OCCASIONS, AN EVOLUTION TAKES PLACE THAT MAKES EVERYONE STOP AND NOTICE.

Top view of six-sided inner tub and automatic prewash, detergent, bleach, and softener dispenser. Clothes are cleaner with Staber.

66 Ways to Save Energy and Lower your Electric Bill. Just follow some of these easy, inexpensive energy saving tips.

TOP LOAD WASHER AWNA62 MADE IN AMERICA, BUILT TO LAST SINCE 1908

etell Intelligent Controls Advanced Air Quality Controls for Dust Collection Systems

CHELAN COUNTY FIRE DISTRICT 5

BT16.4SS-HK BT19.4SS-HK Cooker Hood

The Proven Performer for the Healthcare Industry

Technology Menu Self-Service Laundry

EXHIBIT 1. Washington Home Energy Savings

Crosley CFW7700/CDE/G7700 Front Load Washer and Dryer

Technical. Data Sheet. 3M Scotchlite Reflective Material 5535 Segmented Flame Resistant Trim. October Description. Retroreflective Performance

OPERATING & MAINTENANCE MANUAL

elaundercare; On Premise Laundry Procedures

VS Series. Variable Speed Rotary Screw Compressors

EXPERTS IN INDUSTRIAL LAUNDRY

SUNDAY, MARCH 19 MONDAY, MARCH 20

BWTC6510GL Cooker Hood 60 cm Glass cooker hood in stainless steel. BWTC9510GL Cooker Hood 90 cm Glass cooker hood in stainless steel

2016 North American Firefighter Personal Protective Equipment New Product Innovation Award

Facility Cost Savings Guide. How to Increase Employee Productivity and Decrease Energy Cost in Your Industrial Space

WHIRLPOOL 6 TH SENSE COLOURS WASHING MACHINE.

obtained frm- implementation of alternative, cost-effective cleaning technologies.

Understanding and Analyzing Your Washing Machine From a Human-Computer Interaction Perspective

Active Dry Air Venting for Water Contamination Control

Transcription:

By Haley Jorgensen 5-12-10 Selecting the Right Washer-Extractor for Turnout Gear Care Although it s critical to properly clean soiled turnout gear to prevent the transfer of carcinogens, particulates and biohazards to firefighters, and those they serve, it isn t easy to determine which washers are most appropriate to do the job. Turnout gear demands specific cleaning care to remove contaminants and prevent fabric damage. Through the use of the right washer-extractor, turnout gear can be properly cleaned preserving the gear s protective integrity without damage. Firefighters know dirty gear is dangerous. As more and more particles attach to protective gear and chemicals remain on clothing, that gear gradually loses its effectiveness putting firefighters at increased risk. The apparel that s designed to protect, may then facilitate a dangerous event because it reflects less radiant heat, becomes more flammable and can even conduct electricity (Stull and Stull). But, how should a fire department go about choosing the right washer-extractor to properly clean gear? Using evidence, National Fire Protection Association (NFPA) 1851 guidelines, and expert advice, this paper serves to clearly define which washer-extractor features are required to properly clean turnout gear, and which features best fit the needs and installation requirements of most firehouses. In the end, a highly programmable, front-load washer-extractor with automatic chemical injection is critical. Depending on the application, many firehouses will also require highefficiency, soft-mount (freestanding) washer-extractors, which are simpler to install and allow for installation flexibility that hard- or rigid-mount washers do not. How Programmable is Highly Programmable? Why Programmability is Critical When cleaning turnout gear, fire departments should follow manufacturers recommendations and NFPA 1851 guidelines for the care and maintenance of protective apparel (NFPA, Stull and Stull). NFPA 1851 guidelines indicate that soiled protective gear be washed in a highly programmable, front-load washer-extractor. Front-load washers eliminate the possibility of damage from agitation, while a highly programmable washer allows fire departments to easily alter how they wash gear based on changing recommendations and fabric innovations (Jorgensen, Stull and Stull). That means the washer is programmable enough to handle the washing specifications of today s protective gear and emerging protective fabrics still on the horizon. A highly programmable machine allows the user to program every variable of the wash process, including extract speed in G-Force, number of baths, water temperatures, water levels, cylinder rotation options, mechanical action, wash time and automatic chemical injection. By investing in a highly programmable washer, fire departments can properly clean virtually any

fabric type. Once the machine is programmed, the user just enters a code and presses start. The gear is cleaned automatically and properly every time with the right mix of chemicals, water temperature, water levels and extract speed. So no matter who is doing the wash, the load results are perfectly consistent every time (Jorgensen). The highly programmable Continental Girbau E-Series Washer-Extractor is a good pick for any fire department. It allows the user to program every variable of the wash process, including extract speed (from 2 up to 387 G-force), multiple baths, water temperatures, water levels, cylinder rotation options, mechanical action, wash time and automatic chemical injection. Making things simpler, the Continental E-Series Washer-Extractor can be programmed upon installation by chemical representative to clean turnout gear liners and shells according to NFPA guidelines, which suggest that the liners and shells be washed separately; water temperatures do not exceed 105 F; extract speeds do not exceed 100 G-Force; and a mild detergent is used with a Ph level between 10.5 and six (Jorgensen and NFPA). Fire departments should seek out a reputable chemical supply company with a representative accustomed to programming washers for cleaning protective apparel. That representative should know to follow NFPA and manufacturers guidelines. Why Automatic Chemical Injection is Important A washer-extractor with automatic chemical injection has the capability to automatically inject exact amounts of cleaning chemicals at exactly the right time in the wash process and at the right water temperature. It is very important that fire departments choose a washer-extractor with this feature, like the Continental E-Series Washer, because it prevents chemical overuse and damage to fabric (Jorgensen). When chemical overuse occurs, sensitive protective fabrics can be damaged, bleached, or made useless. Many fire departments have multiple people doing the wash, which can contribute to accidents and chemical overuse. But, with automatic chemical injection, no one adds detergents manually, ensuring the correct quantity every time. Protective firefighting gear is costly. A highly programmable washer with automatic chemical injection can be programmed to clean correctly simply by entering a program number and pressing start. A Soft-Mount/Freestanding Design is Key to Easy Installation, Maintenance While not as critical as programmability and automatic chemical injection, a washer-extractor that is freestanding is almost always better than a hard, or rigid-mount washer. Freestanding washers like the Continental E-Series model have a soft-mount design that dramatically simplifies installation, and resulting costs (Jorgensen). While a soft-mount washer does not require a reinforced concrete foundation, hard-mount washers do. Hard-mount washers must be bolted to a thick, concrete foundation; are harder to access for maintenance; and more cumbersome to relocate. Conveniently, soft-mount washers can be installed nearly anywhere there is extra

space, including truck bays with in-floor heat, utility areas and second-floor laundry rooms (Jorgensen). They are also easier to service and maintain because they are more accessible. Soft-mount washers like the Continental E-Series Washers are also simple to relocate if needed. If a fire department is looking for a washer that s easy to install and service, choose one that offers a soft-mount design. Superior Efficiency Essential to Reducing Costs Many fire departments are on the cutting edge when it comes to conserving natural resources and energy. As a result, fire departments can demonstrate they are using taxpayer money effectively. By purchasing an energy-efficient washer-extractor, fire departments can demonstrate lower natural gas, water and electricity usage and costs. This is why it is important to consider how energy-efficient a washer-extractor is before it is selected. Among the most efficient industrial washer-extractors on the market are the Continental E-Series Washer-Extractors, which come in 20-, 30-, 40-, 55-90-, 130- and 255-pound capacities. Depending on laundry volume, most fire departments install 20-, 30-, 40- or 55-pound capacity washers to handle the proper cleaning of turnout gear (Jorgensen). There are a couple of resources that evaluate the efficiency of 20-pound capacity washerextractors, but none that rate the efficiency of larger models. However, some manufacturers of washers do have their washers evaluated for efficiency by independent laboratories. First, Energy Star and the Consortium for Energy Efficiency (CEE) are both organizations that classify a washer s efficiency in the 20-pound capacity category. Energy Star, for example, lists the Continental E-Series 20-pound capacity washer-extractor among the most energy-efficient in its class of industrial commercial washer-extractors (Energy Star). Similarly, CEE classifies small commercial washers into tiers of efficiency, with Tier 3 being most efficient (http://www.cee1.org/com/cwsh/cwshspec.pdf). According to the CEE, Tier 3 washers must have an Modified Energy Factor (MEF) of 2.20 or greater. MEF is a combination of energy factor and remaining moisture content. MEF measures energy consumption of the total laundry cycle. It indicates how many cubic feet of laundry can be washed and dried with one kwh of electricity; the higher the number, the greater the efficiency (CEE). Although the CEE doesn t classify large-capacity washers, it does give laundry equipment consumers a guideline for efficiency. For example, the Continental E-Series 55-pound capacity washer-extractor underwent testing by an independent laboratory Intertek for efficiency. According to Intertek test results, the 55-pound capacity E-Series Washer produced an MEF of 2.34. The MEF of the 55-pound E-Series model aligns with CEE s highest efficiency tier Tier 3 (CEE, Continental Girbau). Additionally, the E-Series 20-pound capacity model is classified as a Tier 2 washer for efficiency by CEE.

In order for fire departments to save natural resources and costs, fire departments should select an energy-efficient washer-extractor, similar to the Continental E-Series. Selecting A LEED-recognized Washer-Extractor Sustainable construction is becoming a standard practice throughout most construction markets in the United States, with an increasing number of projects becoming LEED-qualified (LEED). The U.S. Green Building Council s (USGBC) Leadership in Energy and Environmental Design (LEED) Green Building Rating System has become the nationally accepted benchmark for qualifying, measuring and documenting green buildings. Sustainable construction focuses on developing buildings, including firehouses, which use less energy and water and offer a healthy working environment. In the case of new, sustainable construction, many industries are turning to LEED for guidance and certification. By selecting a washer that is LEED-recognized, like the Continental E-Series Washer-Extractor, firehouses are a step closer to attaining LEED certification (USGBC). For detailed architectural specifications of washer-extractors that meet this criterion, visit www.arcat.com. Grant Dollars to Fund the New Washer Because clean turnout gear is critical to firefighter safety, fire departments across the United States often seek funding for the purchase of new washer-extractors via the Federal Emergency Management Agency s Assistance to Firefighters Grant Program (AFGP). The AFGP is in place to improve firefighter safety, and each year, funds new washer-extractor purchases for fire departments across the United States. To apply for an AFGP grant, visit www.firegrantsupport.com/content/html/afg/default.aspx. After all, clean gear is critical to limiting a firefighter s exposure to life-threatening chemicals, blood, body fluids and particulate matter (Stull and Stull). Through the careful selection of washer-extractors, fire departments can ensure gear is properly cleaned according the NFPA 1851 guidelines; that installation is simplified; that any member of the department can do the wash without damage to protective fabrics; and that the washer s energy-efficiency keeps utility costs in check. Most of all, fire departments can feel secure knowing gear is properly cleaned for firefighter protection.

Works Cited An Introduction to LEED. U.S. Green Building Council, 2010. www.usgbc.org/displaypage.aspx?categoryid=19 ARCAT, 2010. www.arcat.com/arcatcos/cos44/arc44467.html Assistance to Firefighters Grant Program (AFGP), Federal Emergency Management Agency, 2010. www.firegrantsupport.com/content/html/afg/default.aspx CEE Commercial, Family-Sized Washer Initiative Qualifying Product List. Consortium for Energy Efficiency (CEE), 15 April. 2010. http://www.cee1.org/com/cwsh/cwshspec.pdf Continental Girbau, 2010. www.continentalgirbau.com. Energy Star Qualified Commercial Washers. Energy Star, 2010. http://www.energystar.gov/index.cfm?fuseaction=clotheswash.display_commercial_cw Jorgensen, Joel. Choosing the Right Laundry Equipment a Q&A with Industry Veteran Joel Jorgensen. Command Post Extra, Fire Chief, 16 April. 2009. NFPA 1851: Standard on Selection, Care, and Maintenance of Protective Ensembles for Structural Fire Fighting and Proximity Fire Fighting. National Fire Protection Association (NFPA), 2008. www.nfpa.org/aboutthecodes/aboutthecodes.asp?docnum=1851 Stull, Jeffery and Grace. Contamination and Decontamination of Bunker Gear. FireRescue1.com, 17 July. 2006. Stull, Jeffery and Grace. The Proper Care and Maintenance of Turnout Clothing. FireRescue1.com, 29 March. 2006.