Linear drive component Maintenance

Similar documents
Thank You & Congratulations On Your Purchase of: ARBE Model # SS-206 Table Top Dust Collector

Specification Page 1 / 7

Maintenance 5-1. Good maintenance is essential for cleaning results, and long economical life of the washer.

GRIND PRO DUAL OR DISC SANDER. Operator Manual

V-VTP Maintenance Manual

PRO 2000i LOW LEVEL DEPOSITOR

UM120W OPERATING MANUAL MANUAL WATERBORNE GUN CLEANER CAUTION FOR WATERBORNE PAINTS ONLY UNI-RAM CORPORATION ONTARIO CANADA

NSS STANDARD-SPEED FLOOR MACHINES

LITTLE BLASTER LARRY HESS AND ASSOCIATES, INC. BLAST-IT-ALL P.O. BOX 1615 SALISBURY, NC WITH DUST COLLECTOR

Power Washer Maintenance

Owner s Manual PS-200

INSTALLATION and OPERATION BALL WASHER, HIGH CAPACITY MODEL NO: BW-022AN

OWNER S MANUAL. Models: Herkules Equipment Corporation 2760 Ridgeway Court Walled Lake, MI USA Fax

OPERATING MANUAL UG2000D SERIES SPRAY GUN CLEANERS UG2000D, UG2000DM UNI-RAM CORPORATION ONTARIO CANADA UG2000DM UG2000D REVISION

OPERATING MANUAL MANUAL WATER BASE GUN CLEANERS UM120W UNI-RAM CORPORATION ONTARIO CANADA PATENTS

Technical Bulletin. 1405F/DF Switching Valve Maintenance NEW DESIGN Bulletin # TS0062 Rev 05/2016

OTO BONDER OWNER S MANUAL WITH CIRCULATING SYSTEM MACHINERY DIVISION - - L to R Unit Shown

APPENDIX 4. Thank you for choosing the Biomega BioClave steam sterilizer. HYDRAULIC DRAWING

CAUTION UM120W (RIGHT TANK) FOR WATER BORNE PAINTS ONLY UM120W (RIGHT TANK) SECTION IS NOT DESIGNED FOR USE WITH SOLVENT BASED PAINT

Audi-Larm Audible Alarm

User Manual AIR HOG. Vacuum Booster REV. 3/20/ Stowe Dr. Poway, CA P: (858) F: (858)

User s Guide REO-MECH. Industrial Rebar Benders & Cutters

INSTRUCTIONS & PARTS LIST FOR NO. 658, 660, 690, 697 SIOUX AIR RANDOM ORBITAL SANDER INCLUDES B, V, VV, & X SUFFIXES (SERIAL E )

Tornado Operations & Maintenance Manual

ENGLISH (Original instructions) INSTRUCTION MANUAL. Demolition Hammer HM0810TA DOUBLE INSULATION. IMPORTANT: Read Before Using.

INSTALLATION and OPERATION BALL WASHER MODEL NO: BW-022

G-7s. Instruction Manual. G-Series Cooler COUNTERTOP COOLER. Part No.11IPA

OPERATOR S MANUAL. BASIC PROJECT CENTERS Some instructions and drawings may not apply to your specific unit. SAFETY SERVICE PARTS CAPACITIES

OPERATING INSTRUCTIONS

BLAST-IT-ALL BUMPER BLASTER

Owner s Manual PS-50. Document Number: Revision: Draft

L07 - L22. Oil Injected Rotary Screw Compressors. Intelligent Air Technology

Thank You & Congratulations On Your Purchase of: ARBE Model # MD-205 Table Top Dust Collector

Electric Honey Extractor

GALAXY FLOOR MACHINE

MACHINE SHOP ACCESSORIES CLEVER, TIME-SAVING PRODUCTS TO MAKE YOUR LIFE EASIER

ATD /8 Electric Drill

Instructions for Model E782 Betman Cleaning System (Cleaner/Rinser/Rinser/Dryer)

Atlas Copco. Oil-injected Rotary Screw Compressors Variable Speed Drive + (7-15 kw/10-20 hp)

TECHNICAL MANUAL TRAY DRYER

HF345 S9 Operators Manual

OK, OKA, OKAF; ELD; ELDM; ELH; OKC; SC; SCA; SCAF; OK-LN; OKA-LN; OKAF-LN.

CONSTANT SUCTION UNIT

P.O.D. Pressure On Demand

Environmental Design The tank has separating devices at the exhaust port to prevent oil-spraying and to reduce pollution.

ModulAir Air Dryer with External Purge Tank - Changeover from Bendix AD-IS for Peterbilt Installation. Air Dryer Mounting Bracket (Item 1)

Explorer CleaningPartsDirect.com Carpet Extractor. Operator and Parts Manual. Home Find... Go To.. Model No.: Can.

Installation, Operation, and Maintenance Manual

S150 S300 CONSTRUCTION HEATERS. Rev: August 15, 2008 SERVICE AND MAINTENANCE MANUAL No PLEASE RETAIN FOR FUTURE REFERENCE PRODUCTS

Ozomax Ltd Ozone generators

TLA-1245 EFFICIENT HEAT CYCLE SHRINK TUNNEL OPERATION MANUAL

Downtime Instructions

OPERATING MANUAL SOLVENT SPRAY GUN CLEANERS UG5000E, UG5000DVM AND UG5500E UNI-RAM CORPORATION ONTARIO CANADA PATENTS

Packaged Heat Pumps. Owner s Guide to Operating and Maintaining Your Heat Pump

INSTALLATION, OPERATION AND MAINTENANCE MANUAL FOR MODEL RH REMOTE HORIZONTAL AIR COOLED HEAT EXCHANGERS

Montageanleitung RLO (Original) Mounting Instructions RLO (Translation of the original)

cooling tower downtime instructions

Operator s Manual for Morse Hydra-Lift Drum Karrier Model 400A

KG 092 SHOWN READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

Bread Slicer, Countertop STANDARD OPERATING PROCEDURE

Precision Specialties

I.O.M. #116 7/10 INSTRUCTION MANUAL INSTALLATION OPERATION MAINTENANCE. Covers Models from 25 to 100 tons.

OPERATOR S MANUAL. For BURLY ATTACHMENTS

INSTALLATION AND SERVICE MANUAL FOR THE SERIES 1000-P FAN SERIES (PNEUMATIC CONTROL) SERIES 1000-H FAN SERIES (HYDRAULIC CONTROL) GEN 2

Centrifugal Fans maintenance manual

D O U B L E A U G E R M O R TA R M I X E R OWNER S MANUAL

BEFORE OPERATING THE MACHINE: WARNING

INSTALLATION, OPERATION & MAINTENANCE MANUAL FOR DRY PAK PACKAGED COMPRESSED AIR TREATMENT SYSTEM MODEL: DPP-150 WARNING

DS series STERLING PUMPS. Industrial End Suction Pumps ISO/DP

Fig. 1 - Unit PHD4 and WPH4

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

Fan Motor. user manual INSTALLATION - OPERATION - MAINTENANCE

OPERATION & MAINTENANCE MANUAL TC670

VACUUM PACKAGING MACHINE

Operator s Manual for Morse Heavy-Duty Hydra-Lift Drum Karrier

User's Infomation Manual

TC-710 RECYCLING BALER

USER MANUAL SPRAY GUN CLEANER - WATER BASED PAINTS UA400W CAUTION FOR WATER BORNE PAINTS ONLY

Operator & Parts Manual Floor Burnisher ib REV.01( ) INTERNATIONAL CLEANING EQUIPMENT

Operating Instructions for the BBO-1 and BBO-2 Basket Blasters

MULTIWASH XL OPERATOR S MANUAL & PARTS LIST PFMW18. Save These Instructions

Warranty Details page 2. Pump Description & Technical page 3 Specifications. Transportation, Storage & Installation page 4. Pump Maintenance page 5

Technical Data. Name: ERIKA Automat fully automatic machine to divide and to round dough pieces of the same size

Operator s Manual. Linear Asphalt Compactor. Jesse D. Doyle Isaac L. Howard, PhD Mississippi State University. January 2010 CMRC M 10-1 Version 1

CleanSpray System Operation

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Outdoor Unit UQB09JJWC UQB12JJWC. Indoor Unit AQB09JJWC AQB12JJWC

User s Information Manual

G-10s. Instruction Manual. G-Series Cooler UPRIGHT COOLER. Part No.11IPA

TOS-002-US Gear Hobbing Machine TH 350 CNC

Owner s Information Manual

Owner s Manual READ AND SAVE THESE INSTRUCTIONS

ULTRA LOW TEMPERATURE FREEZER. User Manual

Compact. Cost effective. Productive. GSW-V Vacuum Gripper

TCUT10UL 2.5 HP 10 Tile Saw Assembly & Operating Instructions

OPERATION & MAINTENANCE MANUAL AC860

OPERATING MANUAL SPRAY GUN CLEANERS UG UG3000 SERIES UNI-RAM CORPORATION ONTARIO CANADA PATENTS

KRF15A-03 KRF25A-03 KRF40A-03

Agilent Dissolution Seminar Series

Chargebuster Ion Gun Installation, Operation and Maintenance

3 Steps to Smoother Baler Operation

Transcription:

1 P age Service and Maintenance Caution (1) Maintenance shall be performed by qualified personnel. (2) Switch off the main power supply before servicing. If power supply is needed, have qualified personnel operate it. (3) Use genuine replacement parts and components. Linear drive component Maintenance Wipe the linear rails and bearings once a day to assure smooth play free motion. Lubricate the rack and pinion and the ball screw drive once every week so as to ensure longer service life. When lubricating the z-axis screw, use a grease gun to inject grease into zerk fitting. It is recommended to use Kluber TA 15/2 or PETAMOGY 193 or equivalent.

2 P age Electrical Cabinet Maintenance Caution: Switch off the main power supply before servicing. If power supply needed, qualified personnel shall operate it. (1) Clean the cabinet with dust collector once every week. Be careful not to damage or loosen any wire connections. Compressed air may be used but from at least 4 foot distance. (2) Check the fan filters every month. Clean and / or replace if necessary. Maintenance Intervals on Becker VTLF 250 Series Pumps Every 50 Hours -Check to make sure the pump is free of any debris or materials leaning against the pump. 18 perimeter clearance is required for proper ventilation. -Check and clean air intake filters. Replace if Necessary. -Clean more often in dirty environments.

3 P age 9 months to Yearly or after 4,000 hours *Check Vanes for minimum width (41 mm). Replace if necessary. *Inspect vanes for improper wear (cupping). Replace if necessary. *Inspect teflon tube seals in end shield. If the hollow center shows through, replace them. *Wipe grease off rotor shaft before re-installing the end shield. *Grease bearings, Use only Amblygon TA 15/2 Grease, 6 or 7 pumps of the grease gun per fitting. DO NOT OVER GREASE Every 3000 to 4000 Hours *Inspect motor coupling. Replace if necessary. Spindle Safety Instructions NOTE: Refer to spindle manufactures manual for more detailed information. Below is basic tooling maintenance. Use ISO 30 tool holder 1) Warm up spindle each day before use. See spindle manual for details. 2) Use original tool holders only. 3) The tool holder must be in the upright position during tool changing. 4) Air pressure needs to be 85-100 PSI during tool changing. NOTE: For best operation and spindle longevity it is recommended to have a clean drive non fluctuation air source. Air dryer recommended. 5) Clear the dust in the spindle regularly. 6) Keep the tools sharp and clean. The workpiece needs to be secured tightly on the table otherwise work piece can become loose and create tool vibration. 7) Change the filter in the oil-water separator on a monthly basis. Empty the water every 8 hours. Blow air into the middle hole and make sure there is no oil. Warning: water and oil in the air lines can damage the spindles moving parts. 8) The air needs to be filtered to be free of moisture, oil mist and dust before entering the spindle. 9) ISO30 tool holders and collets should be cleaned weekly. It is recommended to use a rust prohibitor. (Techno p/n: H25XOS-33-21) Other maintenance To ensure longer service life, perform regular maintenance of the parts and components: (1) Check the overtravel limit switches (both software limit switch and mechanical stops) regularly. Do not let rust accumulate on the limit switches as it seriously affects their

4 P age sensitiveness and may fail to give alarm when the machine over travels, which could lead to mechanical crash and damage to the machine. The way to check is to press the switch with hand and see if it gives off alarm. You can also check if the I/O port input signal changes. (2) Regularly check the electrical parts. Make sure the plug in devices, cables and cords are well connected. Keep the cabinet door closed when in operation. Opening the cabinet door will not help it cool down. Regularly check and clean the fans and filter nets to ensure proper ventilation. (3) You are encouraged to utilize the machine and do not let it stay idle for long, especially in the first year. The more you use the machine, the more likely the machine will be in good condition in the future. If the machine stays idle for too long, the electrical parts are exposed to moisture, heat, etc., thus reducing the service life of the machine. Make sure to power up the machine from time to time (at least once a month). Perform regular check and maintenance. Run the machine for one hour each time and the heat generated will help reduce the humidity. This will also help you to find problems with the machine in advance.

5 P age Appendix I Daily Maintenance Sheet

6 P age Appendix II Common Errors and Solutions Driver Error Codes

7 P age List of Alarms for VFD

8 P age

9 P age