intarpack intarpack axial MDE / BDE series air-cooled condensing units High power in the smallest space. Tropicalised design for ambient temperature

Similar documents
intarpack refrigeration centrals intarpack intarpack centrifugal axial self-contained refrigeration centrals MDV / BDV / MDE / BDE series

intarpack refrigeration centrals intarpack intarpack centrifugal axial self-contained refrigeration centrals MDV / BDV / MDE / BDE series

Condensing units with inbuilt control board, to be connected to refrigerated cabinets and special evaporating units...

Process glycol chillers

CHAPTER 6 CONDENSING UNITS

50VZ (40PZ/38VZ) Vertical Air-Cooled Split-System Cooling Units. Nominal cooling capacity kw

intarpack chiller refrigeration chillers MWE / BWE series

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

Aquaflair TRAC-TRAF-TRAH

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

Split-system cooling units and heat pumps SERIES. Outdoor unit. Indoor unit OPERATING LIMITS. Inlet air conditions Cooling Heating.

LZT High efficiency air to water heat pumps with E.V.I. compressors

LZA High efficiency air to water heat pumps with HP compressor

Roof top SPACE RPC 450Z R407C M011

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1

AQUASNAP JUNIOR 30RHV

LSA LSA A + Air cooled water chillers with axial fans VERSIONS ACCESSORIES

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

CONDENSING UNITS AIR COOLED CONDENSER. COOLING ONLY

LSK LSK. Air to water chillers and heat pumps VERSIONS ACCESSORIES

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

PRODUCT GUIDE

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

Chiller units and air-water heat pumps RANGE OPERATING LIMITS

High temperature air-to-water heat pumps

condenciat cl Condensing units Outdoor condensing unit Variable speed propeller fan Use Description for direct expansion applications

CZT CZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSIONS ACCESSORIES

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

LDK LDK. Air to water chillers and heat pumps VERSIONS ACCESSORIES

Kälte Klima. Air cooled water chillers air cooled reversible heat pumps from 45 kw to 320 KW. Compressors Scroll SCAEY DE 88 04/11 12/10

Roof top SPACE RPC 315Z R407C MA00

CIATCOOLER LJA. Chilled water production units USE. Attractive design, Compact and quiet


pyxis hp "u" pyxis hp "u" IDEA NEW rcgroupairconditioning

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

CHG AIR COOLED WATER CHILLER WITH CONDENSATION BY HELICOIDAL AIR 8 to 17 kw

ZETA kw. Installation, operating, and maintenance manual. Manual B02 Issue Replaces 04.02

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

Compact and silent Scroll compressors All-season operation

LZT High efficiency air to water heat pumps with E.V.I. compressors

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

Motor-driven condensing units MTE MTE R-410A

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw

AQH 40 to 130. u Air-to-Water Reverse Cycle Heat Pumps. 40 to 131 kw. 45 to 141 kw. Engineering Data Manual

Dunham Bush Air Cooled Screw Chiller AFVX B 6SR Series

nemo a hp rcgroupairconditioning R410A

EXPAIR. Use. Precision air handling cabinets. Reducted footprint Dual-wall construction

RAS Kp AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 LIQUID CHILLERS - AIR COOLED AIR

Application guide Installation, operating and maintenance manual AIRCUBE - KSCM/KSHM. Providing indoor climate comfort

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

Компрессорно-конденсаторные агрегаты. Chiller. AQH DCI 20 to 30. Air Cooled Water Inverter Heat Pump Engineering Data Manual. 20 to 30 kw.

4,5 22,5 kw. technicalcatalogue. Air-conditioned server-racks for direct installation into the room T_CLSEVO_0113_GB

WZT High Efficiency Air to Water Split System Heat Pumps With E.V.I. Compressors

PHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER 9 to 18 KW

pyxis pyxisa NEW rcgroupairconditioning

pyxis u pyxis ua NEW rcgroupairconditioning

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

Condensing Units CUS 15-60

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

Большая библиотека технической документации каталоги, инструкции, сервисные мануалы, схемы.

SELF CONTAINED HORIZONTAL AIR CONDITIONERS WATER COOLED CONDENSER (COAXIAL REFRIGERANT-WATER HEAT EXCHANGER)

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw

CATALOGUES SUMMARY - WCHBZ Pages WCHZ Pages 19-42

MACH N-407 Heat Pump Air-Cooled Chiller

PYXIS U PYXIS U. rcgroupairconditioning

pyxis cla pyxis cla A-CLASS NEW rcgroupairconditioning

60 Hz. Catalogue_2016 REFRIGERATION UNITS. - Commercial Range -

TECHNICAL MANUAL FOR AIR-COOLED CONDENSING UNITS MTE

AIR COOLED FREE-COOLING CHILLERS WITH SCROLL COMPRESSORS AND AXIAL FANS

ROOFTOP PACKAGED AIR CONDITIONERS

30GK. Air-Cooled Liquid Chillers. Nominal cooling capacity kw

unico pf unico pf rcgroupairconditioning

Aquair BCP. Pool air handling units. Electronic Control Optimized energy consumption DESCRIPTION PRINCIPLE SCHEMES RANGE OPERATING LIMITS

LZT LZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSION ACCESSORIES

AQUACIAT. Water chillers. Free cooling modules for AQUACIAT2 700V to 1100V AQUACIAT POWER 1200V to 1800V USE RANGE FREE COOLING

ACMVTECH HIGH EFFICIENCY UNITARY AHU

GLIDER EVO FREE GLIDER EVO FREE GLYCOL FREECOOLING. rcgroupairconditioning

RTA TECHNICAL MANUAL AIR-WATER CHILLERS AND HEAT PUMPS FOR OUTDOOR INSTALLATION O L S E A F RA N

EQEF TECHNICAL CATALOGUE AIR COOLED WATER CHILLERS AXIAL FANS WITH FREE-COOLING SYSTEM

Modular Air Cooled Scroll Chillers

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers

MAC N-407 Air-Cooled Chiller

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 385 kw. Scroll Compressors SCAEY-FC DE 98

Reduce everything but reliability

Air Cooled Chillers & Heat Pumps WinPACK HE-A

OACS Outdoor Air-Cooled Central Chillers

E U R O V E N T CERTIFIED PERFORMANCE

AQUACIAT. Water chillers. Free cooling modules for AQUACIAT2 700V to 1100V AQUACIAT POWER 1200V to 1800V USE RANGE FREE COOLING

NEMO A Split-system liquid chillers for indoor installation. Cooling Capacity: 5 26 kw

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 365 kw. Scroll Compressors SCAEY-FC DE 98

GENERAL INFORMATIONS

EKS/HE. MultiScroll Air-cooled liquid chillers High efficiency. Solution B - Base I - Integrata

Packaged air cooled liquid chillers for outdoor installation kw. technicalcatalogue T_EGL_1012_GB

RAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS

BETA ECHOS. Air/water cooled chillers and heat pumps kw. General BETA ECHOS is a range of chillers and ductable air-water heat pumps.

HYDRONIC RESIDENTIAL

Transcription:

aircooled condensing units intarpack intarpack aircooled compact refrigeration plants have been designed for outdoor installation, with minimum space needs. intarpack range covers compressor from 8 to 60 HP at positive and negative, in two different construction types: High in the smallest space. Tropicalised design for ambient up to. Rack of hermetic reciprocating or Scroll compressors with noise insulation. Minimum maintenance needs, with simple access through removable panels. intarpack axial intarpack axial aircooled refrigeration plants have been developed for outdoor installation. Each model has been designed to run under extreme ambient conditions, featuring acoustic insulated components for lower noise levels. 63 69

aircooled condensing units technology in refrigeration intarpack axial Description Características Aircooled condensing units, built in a lownoise compact construction in a galvanised steel shell with polyester coating, designed for outdoor installation. 400VIII50Hz supply. refrigerant. Hermetic reciprocating or Scroll compressors, with noise insulation, and discharge muffler, mounted on shock absorbers, with internal klixon and crankcase heaters. Ushape large area condensing coil, in copper pipes and aluminium fins, tropicalised for ambient up to. Variablespeed electronic axial fans with low consumption operation (except for 1000 series), with electronic internal protection, mounted on nozzles, dynamically balanced blades and external protection grille. Refrigeration circuit with single or double suction line, made in copper pipes, equipped with high and low switches, service valves, security valves, liquid receiver and dehydratant filter. Full control and panel, with thermal and magnetothermal protection for compressors, motors and defrosting heater cables. Electronic control for 4 steps, with single or double suction set point, high and low transducers, proportional control of condensation and digital graphical interface. High reliability compressors Maneurop hermetic reciprocating and Scroll compressors are known for their sturdy construction and high reliability operation. Efficient condensation Lownoise condensation fans operating at 900 rpm with speed control function, they preserve condensation under low ambient while they reduce sound level. Lowspeed and lownoise axial motorfans Electronic regulation Every unit features an advanced electronic digital controller with graphical interface as standard, to control compressors rack and fans. Full control and board, with thermal and magnetothermal protection New generation electronic board 74 68 Double suction line circuit with single or double set point Rack of hermetic compressors with noise insulation, discharge muffler and oil balanced Ushape tropicalised condensing coil Control up to 4 steps with single or double suction set point. Fans speed regulation with PID control on condensation. s time control to equilibrate operating times. Condensation protection against extreme ambient by reducing to a lower step. Digital input to read system and. Energy saving mode by programming set point. Alarm management. ModBus communication protocol through RS485 connection (optional).

aircooled condensing units Optionals Oil separator. INVERTER compressor. Anticorrosion coil coating. Optional module for external communication through ModBus protocol and RS485 connection. Inbuilt brazed plate heat exchanger, for condensation heat recovery and hot water production. Double rise line collector in suction line. INVERTER compressor (optional) intarpack condensing units can be equipped with INVER TER compressors, to provide the unit with a progressive variation form 10% to 100% of its cooling capacity, controlled by the electronic regulation. Refrigeration scheme VD CD AP SA SD VR SA SD V VL FL RL VD VC CP V VL FL RL RC VC BP BP CP: COMPRESSOR VL: SIGHT GLASS MV: MOTORFAN VC: COMPRESSOR SERVICE VALVE CD: CONDENSER VD: SECURITY VALVE Applications RL: FL: LIQUID RECEIVER DEHYDRATANT FILTER RC: SD: SA: CRANKCASE HEATER DISCHARGE MUFFLER OIL SEPARATOR intarpack axial aircooled condensing units are designed to give service to a set of evaporating units and other applications at positive and/or negative : LIQUID LINE SUCTION LINE SUCTION LINE Installation of a set of evaporating units with common liquid line and single or double suction line for two different evaporating s, and compressors cooling capacity control. Refrigeration installation to give service to an ice maker, with up to 4 steps. 75 69

aircooled condensing units technology in refrigeration intarpack axial 1000 and 2000 series 1 compressor 1 circuit 400VIII50 Hz capacity (kw) Evaporating : +5ºC 0ºC 5ºC 10ºC 15ºC 20ºC 25ºC 30ºC curent LiqGas db* MDENF1016 8 H MTZ100 MDESF1016 8 Sc SZ100 MDENF1022 10 H MTZ125 MDESF1022 10 Sc SZ120 MDENF2027 13 H MTZ160 MDESF2027 13 Sc SZ160 MDESF2031 15 Sc SZ185 25,0 23,2 21,5 30,7 23,9 28,8 22,7 39,3 31,0 38,7 31,0 43,8 34,8 20,7 16,1 17,4 19,6 19,0 32,7 25,7 32,4 25,8 36,6 29,1 16,8 13,1 16,2 13,8 20,6 15,8 20,0 15,7 26,9 21,0 26,9 21,4 30,4 13,5 10,5 13,3 11,0 16,5 12,6 16,4 13,9 21,8 16,9 22,1 18,4 25,0 21,3 11,1 8,13 10,8 9,86 13,3 17,8 13,4 20,3 8,50 6,12 10,1 7,56 13,6 11,7 6,32 4,37 7,60 5,64 10,4 8,33 4,50 2,85 5,57 7,71 5,60 7,1 19,1 Ø630 11000 6,7 19,3 Ø630 11000 8,9 23,0 Ø630 11000 9,1 24,3 Ø630 11000 12,2 30,3 Ø800 17000 12,0 31,2 Ø800 17000 13,7 35,4 Ø800 17000 1 250 42 255 37 255 41 265 37 310 47 335 47 345 47 10ºC 15ºC 20ºC 25ºC 30ºC 40ºC BDENF1022 7.5 H NTZ215 BDENF1027 10 H NTZ271 BDESF1027 10 Sc LFZ166 BDESF1031 15 Sc LFZ250 16,1 12,5 21,6 16,8 9,9 17,6 13,5 14,3 11,6 21,3 10,4 7,7 14,1 10,7 11,8 9,5 17,6 14,1 8,09 5,9 11,1 8,3 9,63 7,8 14,4 11,6 6,14 4,3 8,49 6,3 7,78 6,3 11,7 9,4 4,50 3,0 6,33 4,6 6,21 5,0 9,40 7,6 3,13 1,9 4,53 3,1 4,90 4,0 7,50 6,1 2,01 3,06 3,80 3,1 5,90 4,8 5,5 17,5 Ø630 11000 7,2 22,1 Ø630 11000 6,3 17,5 Ø630 11000 9,6 24,2 Ø630 11000 1 250 39 255 39 270 37 295 37 Dimensions 1000 series * technical features are related to 10ºC and 30ºC evaporation and ambient, : Sound level shown in db at 10 metres 1015 800 1505 2000 series 1340 1180 type according to the nomenclature: 76 70 1505

aircooled condensing units 3000 and 4000 series 4 compressors 1 circuit 400VIII50 Hz MDENF4034 16 H 2xMTZ100 MDESF4034 16 Sc 2xSZ100 MDENF4043 20 H 2xMTZ125 MDESF4043 20 Sc 2xSZ120 MDENF4054 26 H 2xMTZ160 MDESF4054 26 Sc 2xSZ160 MDESF4062 30 Sc 2xSZ185 BDENF3043 15 H 2xNTZ215 BDENF3054 20 H 2xNTZ271 BDESF3054 20 Sc 2xLFZ166 BDESF3062 30 Sc 2xLFZ250 capacity (kw) Evaporating : +5ºC 0ºC 5ºC 10ºC 15ºC 20ºC 25ºC 30ºC 49,9 39,0 45,6 43,2 61,3 47,8 57,5 45,4 77,0 66,4 76,0 60,3 87,5 70,0 41,3 32,2 39,0 34,7 50,6 39,1 48,2 38,0 64,0 50,0 63,4 50,3 73,2 58,1 33,7 26,2 32,4 27,5 41,1 31,6 40,0 31,5 52,6 40,8 52,7 41,6 60,7 48,2 27,0 20,9 26,6 22,4 33,0 25,2 32,8 27,8 42,7 32,9 43,4 36,8 49,9 42,6 22,2 16,3 21,5 26,0 19,7 26,6 26,1 35,3 40,7 17,0 12,2 20,1 15,1 26,6 20,2 12,6 8,7 15,2 11,3 20,3 15,1 9,0 5,7 11,1 15,0 10ºC 15ºC 20ºC 25ºC 30ºC 40ºC 31,5 24,2 41,3 31,6 25,5 19,2 33,6 28,7 23,2 40,1 20,2 14,9 26,8 20,1 23,6 19,1 33,1 15,7 11,3 21,0 15,5 19,3 15,6 27,2 11,9 8,2 16,1 11,7 15,6 12,6 22,1 18,3 8,7 5,7 11,9 8,4 12,4 10,1 17,8 14,1 6,0 3,5 8,5 5,7 9,8 7,9 14,2 11,3 3,8 5,6 7,6 6,1 11,2 9,9 current 15,5 36,4 Ø800 22000 14,6 36,8 Ø800 22000 19,1 44,2 Ø800 22000 19,4 46,8 Ø800 22000 23,4 57,2 Ø800 21000 23,2 59,0 Ø800 21000 28,6 67,4 Ø800 21000 11,2 33,2 Ø800 17000 14,6 42,4 Ø800 17000 13,9 33,2 Ø800 17000 20,3 46,6 Ø800 17000 LiqGas 1 1 1 1 db* Dimensions 3000 series 1340 1180 1805 4000 series 1740 1480 1 420 49 430 47 425 48 445 47 465 48 505 47 525 47 390 47 395 47 425 47 470 47 * technical features are related to 10ºC and 30ºC evaporation and ambient, : Sound level shown in db at 10 metres type according to the nomenclature: 1805 77 71

aircooled condensing units technology in refrigeration intarpack axial 3 compressors. 400VIII50 Hz MDENF5048 24 H 3xMTZ100 MDESF5048 24 Sc 3xSZ100 MDENF5066 30 H 3xMTZ125 MDESF5066 30 Sc 3xSZ120 MDENF5081 40 H 3xMTZ160 MDESF5081 40 Sc 3xSZ160 MDESF5093 45 Sc 3xSZ185 BDENF5066 23 H 3xNTZ215 BDENF5081 30 H 3xNTZ271 BDESF5081 30 Sc 3xLFZ166 BDESF5093 45 Sc 3xLFZ250 capacity (kw) Evaporating : +5ºC 0ºC 5ºC 10ºC 15ºC 20ºC 25ºC 30ºC 76,5 60,2 70,9 58,2 96,2 75,7 89,6 71,9 116 90,6 114 90,4 129 102 63,3 49,7 59,5 48,7 79,4 62,0 75,1 60,2 96 72,8 95,3 75,4 108 84,8 51,6 40,4 49,4 40,3 64,7 50,2 62,3 49,8 78,9 59,4 79,1 62,4 89,3 70,3 41,4 32,3 40,6 33,0 51,9 40,1 51,2 42,8 64,0 49,4 65,0 55,5 73,4 64,2 32,6 25,1 32,9 41,0 31,4 41,5 51,0 31,7 53,0 59,8 24,9 19,0 26,2 31,8 39,9 27,9 18,5 22,8 30,5 12,1 9,0 16,7 22,5 10ºC 15ºC 20ºC 25ºC 30ºC 40ºC 49,3 38,5 66,2 51,8 40,0 30,7 53,9 41,8 43,8 35,6 65,3 52,4 31,9 24,0 43,2 33,2 36,1 29,3 53,9 43,3 24,9 18,3 25,8 29,4 23,9 44,1 35,6 18,9 13,5 26,1 23,8 19,4 35,7 29,0 13,9 9,4 14,2 19,0 15,5 28,7 23,4 9,8 6,0 14,0 9,8 15,0 12,2 22,9 18,8 6,3 9,5 11,6 9,4 14,8 current 22,1 56,3 2xØ800 44000 20,6 56,9 2xØ800 44000 27,3 68,0 2xØ800 44000 27,1 71,9 2xØ800 44000 35,6 87,5 2xØ800 44000 35,4 90,2 2xØ800 44000 40,7 103 2xØ800 44000 17,4 51,5 2xØ800 44000 22,2 65,3 2xØ800 44000 51,5 2xØ800 44000 37,8 71,6 2xØ800 44000 LiqGas 2x 1 2x 1 2x 1 db* Optional Oil separator. Anticorrosion coil coating. Dimensions 1740 1480 2x 1 2x 1 2x 1 2x 1 885 52 900 50 900 51 930 50 910 51 975 50 1005 50 845 50 845 50 895 50 965 50 * technical features are related to 10ºC and 30ºC evaporation and ambient, : Sound level shown in db at 10 metres type according to the nomenclature: 72 78 2326 2500

aircooled condensing units 4 compressors, double suction line. 400VIII50 Hz MDENF5068 32 H 4xMTZ100 MDESF5068 32 Sc 4xSZ100 MDENF5086 40 H 4xMTZ125 MDESF5086 40 Sc 4xSZ120 MDENF5108 52 H 4xMTZ160 MDESF5108 52 Sc 4xSZ160 MDESF5114 60 Sc 4xSZ185 BDENF5086 30 H 4xNTZ215 BDENF5108 40 H 4xNTZ271 BDESF5108 40 Sc 4xLFZ166 BDESF5114 60 Sc 4xLFZ250 capacity (kw) Evaporating : +5ºC 0ºC 5ºC 10ºC 15ºC 20ºC 25ºC 30ºC 99,8 78,1 92,9 86,3 123 95,6 115 90,8 154 133 152 121 175 139 82,6 664,4 77,9 69,4 101 78,2 96,4 76,0 128 99,9 127 101 146 116 67,4 52,4 64,7 55,0 82,3 63,2 80,0 62,9 105 81,6 105 83,2 121 96,3 54,0 41,8 53,1 44,9 66,0 50,4 65,6 55,6 85,3 65,8 86,7 73,6 99,9 85,2 44,4 32,5 43,0 52,1 39,4 53,2 68,1 52,1 70,6 81,3 24,5 40,2 30,2 53,2 40,3 17,5 34,4 22,6 40,6 30,2 11,4 22,3 30,0 10ºC 15ºC 20ºC 25ºC 30ºC 40ºC 64,5 49,9 86,4 67,1 52,1 39,7 70,3 54,1 57,4 46,4 85,4 41,5 31,0 56,3 42,8 47,2 38,2 70,4 56,2 32,4 23,5 44,2 33,3 38,5 31,2 57,6 46,2 24,6 17,2 25,1 31,1 25,2 46,8 37,7 11,9 18,2 24,8 20,1 37,6 30,5 12,5 7,5 18,1 12,5 19,6 15,9 30,0 24,4 8,0 12,2 15,2 12,3 23,6 19,3 current 31,0 72,8 2xØ800 44000 29,3 73,6 2xØ800 44000 38,2 88,4 2xØ800 44000 38,9 93,6 2xØ800 44000 49,1 114 2xØ800 42000 48,8 118 2xØ800 42000 54,7 135 2xØ800 42000 22,4 66,4 2xØ800 44000 31,0 66,4 2xØ800 44000 30,1 84,8 2xØ800 44000 41,0 93,2 2xØ800 44000 LiqGas 2x 1 2x 1 2x 1 2x 1 2x 1 db* 945 52 965 50 965 51 1000 50 980 51 1065 50 1105 50 905 50 910 50 975 50 1065 50 Optional Oil separator. Anticorrosion coil coating. Combination of positive and negative compressors. Double independent circuits. * technical features are related to 10ºC and 30ºC evaporation and ambient, : Sound level shown in db at 10 metres type according to the nomenclature: 79 73