safety Flame Arrestors Deflagration Type In-line & End-of-Line Versions

Similar documents
CAST-X Circulation Heater. With optional built-in controls, CAST-X 1000 is a straightforward solution, perfect for OEMs and end users.

CAST-X Circulation Heater. CAST-X 2000 is a very versatile heater, with multiple housing, standoff, control and enclosure options.

UNIVERSAL SOLVENT HEATER

SERIES 46000E Bi-Directional In-Line Deflagration Flame Arrester

ENERGY, OIL & GAS. astsensors.com macrosensors.com. Transducer & Transmitter Capabilities. Your sensor business partner...

BASCO TYPE T and TC MOISTURE SEPARATORS and TRAP. ...world leaders in heat transfer technology

BASCO TYPE ES EXTENDED SURFACE PLATE FIN HEAT EXCHANGERS. ...world leaders in heat transfer technology

Leading the world in explosion protection

SCHMIDT- BRETTEN GASKETED PLATE HEAT EXCHANGERS

Overview of Hazardous Locations as They Relate to Solenoid Valves

Brooks MT3600 Series Metal Tube Variable Area Flowmeters

The CAST-X 2500 is our most compact dual-tube model, a powerful and versatile mid-sized heater.

SB Series Brazed Plate Heat Exchanger Installation Manual

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS PENTAIR CLEAN AIR SYSTEMS

FLAME SAFETY DEVICES THAT PROTECT EQUIPMENT, LIVES & THE ENVIRONMENT ARRESTERS DEFLAGRATION // ATEX CERTIFIED

Copy Right By: Thomas T.S. Wan

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

Technical Specification VFD

OPTIBAR DP 7060 Supplementary Instructions

Circulation Heaters Selection Guidelines

Custom Engineered Design. English

Selecting a Safe Tank Gauging Product. Understanding Hazardous Area Definitions for Equipment Approvals

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS

4201 Lien Rd Madison, WI Owner s Manual Therma-Stor III Heat Recovery System. Installation, Operation & Service Instructions

Understanding. Combustible Dust Hazards: Basic Measures to Ensure the Safety of Combustible Dust Handling Operations

Dependable Solutions for Gas Detection

Oil & Gas Oil & Gas. Control Control. every move. Directional Control Valves & Regulators Pressure Controls Temperature Switches Level Controls

Application Alley. SME Fluid Level, Pressure, and Flow Sensors. Helping Customers Win PARTNER SOLVE DELIVER

Explosion Protection Engineering Principles

Thermo-Platens. Cast-In Aluminum and Bronze Platen Die Heaters for Plastics Processing Equipment

Explosion-proof Immersion Heater Type D-8660

Industrial furnaces and associated processing equipment Safety. Part 2: Combustion and fuel handling systems

LTFX Electric Tank Immersion Heaters Installation Instructions

There are always options in the management of explosion risks!

Electronic Pressure Digest. Pressure and Temperature Transmitters

Surface Technologies and Advanced Manufacturing. Tel: + 44 (0) Fax: + 44 (0)

The R. STAHL Technology Group Worldwide Success with Competence and Customer Support

Assembly COM NO NC. Wiring configuration Wiring configuration. 120 VAC power supply (supply voltages 24 VDC and 240 VAC available upon request)

PROCESS AUTOMATION PEPPERL+FUCHS BEBCO EPS 6000 SERIES PURGE AND PRESSURIZATION SYSTEM

Aluminum Dust Management in a Metallizing Facility

Circulation Heaters Selection Guidelines

PROTEGO Deflagration Flame Arresters. and Vent Caps. Volume 2. end-of line. Volume 2. for safety and environment

Test procedure/ method name. method identification. Testing of industrial and explosion isolation valves and tank lining

Hazardous Area Classification in Oil & Gas Industry. A Fire Prevention Tool

CA 134. Piezoelectric accelerometer. IECEx NEPSI TIIS KGS. » From the Vibro-Meter product line» Vibration monitoring over a wide temperature

The heart of electric appliances ELECTRIC WATER HEATING MADE IN ITALY

ELECTRICAL HEAT EXCHANGER FOR PROCESS INDUSTRY

Heavy Duty Pressure Transducers Line Guide

Fire is No Accident Fire is No Accident It can be prevented.

IRceL CH4 Methane (CH 4

Teflon Rotary Drum Pump

HEATING SOLUTIONS VISION SYSTEM APPLICATIONS

SECTION AIR COILS

EXPRESSION OF INTEREST (EOI) FOR. Fire Fighting System (FFS)

HAZARDOUS AREA CLASSIFICATION AND SELECTION OF EQUIPMENT FOR SAFE USE THEREIN FROM AN ELECTRICAL VIEWPOINT

HL SERIES Fluid heating for commercial applications

VACUUM VALVES AND HOSES

PROTEGO Deflagration Flame Arresters. and Vent Caps. Volume 2. end-of line. Volume 2. for safety and environment

NUOVA FRAMAR. Conceive build - produce The experts in zink die-casting and mould design and production.

Assembly COM NO NC. Wiring configuration Wiring configuration. 120 VAC power supply (supply voltages 24 VDC and 240 VAC available upon request)

HEATING SOLUTIONS FLUID SYSTEM APPLICATIONS

ELECTRICAL HEAT EXCHANGER FOR PROCESS INDUSTRY

INTERNATIONAL STANDARD

Application Alley. Utility Meters - Reed Sensor. Utility Meters Use Reed Sensors To Measure Water Flow, Gas and Electricity PARTNER SOLVE DELIVER

C1N & C2N SERIES Fluid heating for light industrial applications

SUNS International LLC. Presentation

Oil & Gas Oil & Gas. Control. every move. Directional Control Valves & Regulators Pressure Switches Temperature Switches Level Switches

Protecting Facilities Against Explosions. Since 1956

High Pressure Water - Descale Valves - VXXX Series. Quad-S TM Poppet Cartridge Zero Leakage, Media Piloted Raw Water Operation

SSL Light Engines. SSL Light Engines Chuck Berghoff, President & CEO

Pipe Thread Heaters. Construction Features. Star Electric to Order Call " 2-1/2" Pipe Thread Heaters

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

[ TECHNOLOGY ] and does this definition affect a burner.

SCHMIDT BRAZED PLATE HEAT EXCHANGERS. ...world leaders in heat transfer technology

Application Alley. Appliance - Reed Sensor. Reed Sensors Detect Dishwasher Spray Arm Obstruction PARTNER SOLVE DELIVER

Flow Switches. Liquid Flow Switches. Mounting Methods

INDEPENDENT FIRE EXTINGUISHER SALES & SERVICES. Your First Line of Defense Since 1971

Explosion-protected actuator Page 259 of 292

Drive Technology \ Drive Automation \ System Integration \ Services * _0817* Inquiry Forms for Explosion-Proof Gearmotors

Thermal Devices, Inc. Mount Airy, Maryland USA

Conducting a NFPA 652 Dust Hazard Analysis (DHA): Practical Tips & Approaches

Band Heaters W A T L O W. Special Mica Barrel and Nozzle

Protecting Critical Facilities Against Explosions

Seat Ventilation offers an extensive range of ATEX certified products and is undertaking great efforts to extend this range even further.

Description. Applications

85 Compensated SPECIFICATIONS. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated

AIR SENTRY DESICCANT BREATHERS

Deluge Valves. Model 68 DE\ EL. Electrically Actuated Remote-Reset Deluge Valve. Dorot Fire Protection Division. Certification & compliance by design

UL Topic III. Converting European EEx Certificates. Into. North American Division Certificates

316L SS Pressure Sensor High Pressure 0-100mV Output Absolute

A Global Leader in Explosion Protection

environmental chambers for Battery testing

Cable Glands DB Series: Drain, Breather Valves and Unions

INTRINSICALLY SAFE Pressure Transducer / Transmitter AST4400

M7100 Pressure Transducer

AQ Group Company presentation. AQ Group AB

Trusting in experience. Relying on expertise. Focusing on solutions. Bebco EPS Purge+Pressurization Product Overview

ASME Packaged Indirect Fired Water Heater

MEAS Subermsible Liquid Level Pressure Transducer SPECIFICATIONS. Features. Applications

HOW LIMIT AND BASIC SWITCHES CAN STOP MACHINES FROM GOING BOOM. A Honeywell White Paper

Transcription:

safety Flame Arrestors Deflagration Type In-line & End-of-Line Versions

FLAME ARRESTORS, BREATHERS AND VENT PLUGS Flame Arrestors to Meet Your Exact Level of Safety and Compliance. TECHNICAL OVERVIEW A flame arrestor is designed to stop the propagation of a flame or explosion to areas where it would cause damage or injury. In some cases, the resulting pressure wave from a detonation situation can be more destructive than the flame itself. A flame arrestor stops the flame and helps disperse the pressure wave. HOW IT WORKS Lisk utilizes a crimped metal ribbon element to arrest the flame and stop it from propagating to the protected environment. The crimped metal ribbon works as a heat sink, designed to provide maximum surface area and thermal mass for absorption and dissipation of heat from the hot gas/flame to the element and ultimately to the atmosphere. In contrast to other types of flame arrestor designs such as wire mesh or sintered metal, the crimped metal ribbon design provides a direct flow path which helps to minimize pressure drop across the element. CLASSIFICATIONS OF A FLAME ARRESTOR Deflagration Arrestor A device designed to stop the propagation of a flame traveling below the speed of sound (approximately 1063 feet/ second). Detonation Arrestor A device designed to stop the propagation of a flame traveling above the speed of sound. Spark Arrestor A device designed to prevent the passage of sparks or embers. Breather Plus A device designed to act as a pressure equalizer or vent. A breather may or may not be designed to act as a flame arrestor as well. End-of-Line Type I Arrestors Located at the end of a pipeline or exit vent where the ignition source is external. In-Line Type II Arrestors Prevent the propagation of flames in piping systems by positioning it in proximity to the potential source of ignition so flames or explosions are confined to the immediate area. FLAME ARRESTOR DESIGN INTENT Lisk flame arrestors are designed for applications that are intended for use in Class I Division I & Class I Division II environments as defined by, NEC, NFPA, IEC (as requested). As part of the design process, Lisk will utilize the information provided in a customer specification and work with the customer to identify a design that would meet their requirements. TYPICAL INFORMATION REQUIRED Flammable media Volume of flammable media Flow rate Allowable pressure drop Operating temperature Distance from ignition/ignition location.

END OF LINE SMALL VENT ARRESTOR Diameter: Up to 1-inch (24mm) Deflagration Type Arrestors for use in systems with small volume/short length, small diameter tubing vent lines where potentially explosive vapors meet atmosphere. LISK has over 60 years of design heritage with Flame Arrestors, our oldest production design was released in 1946. FEATURES Customized to each application, optimized for size, weight, pressure drop, vibration and shock resistance Arrestor element design is specific to application media / flow requirements (reference ASTM F1273, ISO 16852) Designed and 3D modeled with FEA / Computational Fluid Dynamics LISK supported validation testing - internal and third party testing as required for your requirements Threaded housings available for sizes above 0.315 (8mm) with NPT, BSPT, SAE and application specific threads Engineered and built with pride in Clifton Springs, NY - Made in USA MARKETS Aerospace / Defense, Industrial, Energy APPLICATIONS Reservoir / Tank Vapor Venting, Thermal Compensation, Crank Case Vent Assists with Cooling - Electronic Enclosures, Motors MATERIALS HOUSING: Aluminum, 316SS, Inconel, Hastelloy, Titanium, other exotic alloys as necessary ELEMENT: 302/3/4 SS, 316SS, Monel 400, Inconel, Hastelloy SPECIFICATIONS Max. Body Dia., A Overall Length, B Optional Shoulder, C Optional Shoulder, D Maximum Experimental Safe Gap** Min. Ignition Current Ratio** (NEC)* (IEC/ CEC)* LISK Element Weight Max. Pressure Differential Operating Temp.*** Inch (mm) Inch (mm) Inch (mm) Inch (mm) Inch (mm) MIC Group Group Type lbs (kg) PSIA (bar) F ( C) 0.282 (7.16) 0.375 (9.52) n/a n/a 0.75 (19.05) 0.80 D IIA none 0.004 lbs 0.314 (7.97) 0.375 (9.52) n/a n/a 0.75 (19.05) 0.80 D IIA A 0.005 lbs 0.353 (8.96) 0.375 (9.52) 0.035 (8.89) 0.021 (0.533) 0.75 (19.05) 0.80 D IIA A 0.006 lbs 0.369 (9.37) 0.54 (13.71) n/a n/a 0.75 (19.05) 0.80 D IIA A 0.004 lbs 0.44 (11.17) 0.33 (8.38) 0.035 (8.89) 0.035 (8.89) 0.75 (19.05) 0.80 D IIA A 0.008 lbs Dependant 0.44 (11.17) 0.55 (13.97) 0.035 (8.89) 0.035 (8.89) 0.75 (19.05) 0.80 D IIA A 0.008 lbs on Flow Contact and Media. 0.44 (11.17) 0.625 (15.87) n/a n/a 0.75 (19.05) 0.80 D IIA A 0.010 lbs Engineering Contact 0.495 (12.57) 0.75 (19.05) 0.05 (1.27).058 (1.47) 0.75 (19.05) 0.80 D IIA A 0.036 lbs Engineering. 0.625 (15.87) 0.33 (8.38) 0.035 (8.89) 0.035 (8.89) 0.75 (19.05) 0.80 D IIA A 0.012 lbs 0.625 (15.87) 0.725(18.41) 0.035 (8.89) 0.035 (8.89) 0.75 (19.05) 0.80 D IIA A 0.008 lbs 0.94 (23.87) 0.33 (8.38) 0.035 (8.89) 0.030 (0.76) 0.75 (19.05) 0.80 D IIA A 0.026 lbs 0.94 (23.87) 0.625 (15.87) 0.035 (8.89) 0.030 (0.76) 0.75 (19.05) 0.80 D IIA A 0.042 lbs * determination is based on the fuel/flammable media that the unit is designed for use in, ability to withstand flames from other media should be discussed with Engineering. ** Values are described as minimum values as defined by Underwriters Laboratory, if required, actual MESG or MIC should be determined via empirical testing. *** Temperature limitations based on standard materials of construction / brazed element. Other methods available for higher temperatures.

THREADED IN-LINE ARRESTORS Diameter: 1/2-inch (12mm) to 4-inch (100mm) Deflagration Type Arrestors where threaded in-line components are best suited to protect potentially explosive vapors from traveling through tubing / pipes. LISK has over 60 years of design heritage with Flame Arrestors, our oldest production design was released in 1946. FEATURES Customized to each application, optimized for size, weight, pressure drop, vibration and shock resistance Arrestor element design is specific to application media / flow requirements (reference ASTM F1273, ISO 16852) Designed and 3D modeled with FEA / Computational Fluid Dynamics LISK supported validation testing - internal and third party testing as necessary to your requirements Custom housings available in a wide variety of threaded connections NPT, BSPT, SAE & application specific threads Engineered and built with pride in Clifton Springs, NY - Made in USA MARKETS Aerospace / Defense, Industrial, Energy APPLICATIONS Reservoir / Tank Vapor Venting, Thermal Compensation, Crank Case Vent Cooling - Electronic Enclosures, Motors MATERIALS HOUSING: Aluminum, 316SS, Inconel, Hastelloy, Titanium, other exotic alloys as necessary ELEMENT: 302/3/4 SS, 316SS, Monel 400, Inconel, Hastelloy SPECIFICATIONS Max. Body Diameter, A Overall Length, B Connector Type, C Thread, D (NEC) (IEC/CEC) LISK Element Weight Max. Pressure Differential *Op. Temp. Inch (mm) Inch (mm) Type Type Inch (mm) Group Type lbs (kg) PSIA (bar) F ( C) F ( C) 0.5046 (12.81) 0.531 (13.48) NPT 1/2-14 D IIA A 0.008 lbs (0.003) 0.791 (20.09) 1.68 (42.67) NPT 3/4-14 D IIA A 0.10 (0.045) 0.7939 (20.16) 0.531 (13.48) NPT 1-11 1/2 D IIA A 0.010 lbs (0.004) 0.794 (20.16) 0.656 (16.66) NPT 2-11 1/2 D IIA A 0.014 lbs (0.006) *Non- Op. Temp. 0.866 (21.99) 0.19 (4.82) *AS4395-04 (Flare).4375-20 UNJF D IIA A 0.036 lbs (0.016) 1.299 (32.99) 2.75 (69.85) *AS4395-08 (Flare).7500-16 UNJF D IIA K 0.40 (0.181) 1.547 (39.29) 1.92 (48.76) *AS4395-12 (Flare) 1.0625-12 UNJ B IIC L 0.258 lbs (117.027) 1.587(40.30) 3.3 (83.82) *AS4395-16 (Flare) 1.3125-12 UNJ D IIA K 0.23 (0.105) Dependant on Flow and Media. Contact Engineering. - 40 to +130 (-40 to + 54) - 65 to +160 (- 54 to + 71) 1.804 (45.82) 3.113 (79.07) *ASE J514 (Straight) 3/8-27 UNS - 2A D IIA K 0.3 lbs (0.136) 2.75 (69.85) 8.575 (217.80) *ASE J514 (Straight) 3/4-16 UNF - 3A D IIA K 4.40 (1.978) 3.125 (79.37) 2.5 (63.5) *ASE J514 (Straight) 7/8-10 UNF - 2A D IIA A 3.135 (79.63) 2.51 (63.75) *ASE J514 (Straight) 3-8 UN - 1A D IIA A * Temperature limitations based on standard materials of construction / brazed element. Other methods available for higher temperatures.

LARGE FLANGED & CUSTOM ARRESTORS Diameter: 2-inch (50mm) to 8-inch (200mm) Deflagration Type Arrestors for use in potentially explosive atmospheres where the system has a relatively short L/D ratio of unprotected system pipe work or various explosive volumes where protection of a known static volume applies. LISK has over 60 years of design heritage with Flame Arrestors, our oldest production design was released in 1946. FEATURES Customized to each application, optimized for size, weight, pressure drop, vibration and shock resistance Arrestor element design is specific to application media / flow requirements (reference ASTM F1273, ISO 16852) Designed and 3D modeled with FEA / Computational Fluid Dynamics LISK supported validation testing - internal and third party testing as necessary to your requirements Threaded housings available for sizes above 0.315 (8mm) with NPT, BSPT, SAE & application specific threads Engineered and built with pride in Clifton Springs, NY - Made in USA MARKETS APPLICATIONS Aerospace / Defense, Industrial, Energy Reservoir / Tank Vapor Venting, Thermal Compensation, Crank Case Vent Cooling - Electronic Enclosures, Motors MATERIALS HOUSING: Aluminum, 302/3/4 and 316 SS, Inconel, Hastelloy, Titanium, other exotic alloys as necessary ELEMENT: 302 or 304 SS, 316SS, Monel 400, Inconel, Hastelloy ELEMENT WIDTHS (IN,MM) 0.63 (16.002), 1 (25.4), 1.5 (38.1), 2 (50.8) SPECIFICATIONS Max. Body Diameter Overall Length Special Features Maximum Experimental Safe Gap Minimum Ignition Current Ratio (NEC) (IEC/CEC) LISK Element Weight Max. Pressure Differential **Op. Temp. **Non- Op. Temp. Inch (mm) Inch (mm) Note MESG (mm) MIC A, B, C, D IIC, IIB, IIA Type lbs (kg) PSIA (bar) F ( C) F ( C) 1.73 (43.94) 0.75 (19.05) Element >.75 >.80 D IIA K 0.118 lbs (0.053) 1.75 (44.45) 1.1 (27.94) Square Flange >.75 >.80 D IIA A 0.512 lbs (0.232) 2.12 (53.84) 1.1 (27.94) Element >.75 >.80 D IIA A 0.290 lbs (0.131) 2.25 (57.15) 1.5 (38.1) Stepped >.75 >.80 D IIA N 1.778 lbs (0.806) 2.598 (65.98) 1.74 (44.19) Stepped >.75 >.80 B IIC L 1.386 lbs (0.628) 3.75 (95.25) 1 (25.4) Dual Flanged >.75 >.80 D IIA C 1.478 lbs (0.670) 5.95 (151.13) 8 (203.2) Dual Flanged >.75 >.80 D IIA K 6.1 lbs (2.766) 6 (152.4) 1 (25.4) Element >.75 >.80 D IIA A 1.914 lbs (0.868) 7.5 (190.5) 2.4 (60.96) Square Flange >.75 >.80 D IIA A 21.5 lbs (9.752) Dependant on Flow and Media. Contact Engineering. - 40 to +130 (- 40 to + 54) - 65 to +160 (- 54 to + 71) 9.056 (230.02) 4.922 (125.01) Dual Flanged >.75 >.80 D IIA A 23 lbs (10.43) 11 (279.4) 1 (25.4) Element >.75 >.80 D IIA G 10.50 lbs (4.762) 12 (304.8) 1 (25.4) Flanged >.75 >.80 D IIA K 11.35 lbs (5.148) 13 (330.2) 1 (25.4) Element >.75 >.80 D IIA G 5.50 lbs (2.494) ** Temperature limitations based on standard materials of construction / brazed element. Other methods available for higher temperatures.

Internal Testing & Qualification Support Capabilities ENGINEERING LISK is comprised of 650 employees operating in more than 400,000 square feet of manufacturing facilities in Clifton Springs, NY. We maintain complete control of the products we make from design to delivery. Multi-discipline engineering teams capable of designing, detailing, prototyping, and simulation to ensure the product meets or exceeds customer specifications. MANUFACTURING manufacturing capabilities to receive incoming raw materials, confirm composition, machine to detailed specifications, assemble (welding, bonding, molding, brazing), plate for environmental protection, inspect, test, and ship. TESTING overseeing all of these efforts is an extensive Quality Department utilizing state-of-the-art measuring equipment and techniques for product conformance to drawings and specifications. We also conduct extensive testing to support validation and certification processes. Vibration and Shock per RTCA-DO160 Pressure Drop (Air as a media) Pressure Drop (Viscor as fuel substitute, limited to <1.0 to 15.0 GPM) Proof/Burst Pressure Testing Qualification Testing Coordination and Support for all types of testing: Any tests not performed by LISK on premises can be coordinated by LISK utilizing a host of well established test facilities across the US as well as in Europe. Testing capabilities include but not limited to: Flame Suppression (ISO 16852, ASTM F 1273, EN 12874, etc.) Lightning/Induced Transient Icing High Flow/pressure drop testing (Fluid) Endurance Life testing (Fluid Flow) Quality Certifications ISO 9001:2008 (General Quality Management) AS9100C (Aerospace QMS) TS16949:2009 (Automotive QMS) ISO 14001:2004 (Environmental Management System) NADCAP Aerospace Process Certifications Electroless Nickel Plating Cadmium Plating Passivation Gas Tungsten ARC Welding High Energy Beam Welding Currently pursuing NADCAP Certifications for Brazing

From Design to Delivery, We Do it All In-House So Let s Talk. Engineer to Engineer. We thrive on your imagination. On your challenges. On your goals. As you push industry norms, we push even further to accommodate your innovative designs. With limitless customization, your options are virtually endless. And because there are so many options, we want our OEM engineer partners to know our capabilities. LISK is a global leader in the design and manufacture of custom solenoids, solenoid valves, sensors, and flame arrestors that are engineered specifically for customers in diverse markets throughout the world including, aerospace, defense, heavy duty engine, mobile industrial equipment, and oil and gas. Total In-house Capability for Design, Development & Manufacture Our philosophy of maintaining complete control of the design, manufacture, and quality of LISK products has led to a substantial investment in equipment, facilities, and training. This enables delivery of every order to specification, on time and on budget. DESIGN & ANALYSIS 3D CAD design capability. Element (including finite) analysis in vibration, shock, temperature, magnetic, flow, heat transfer, and stress. R&D LABORATORY Electrical characteristics, operational performance including pneumatic and hydraulic pressure/flow stands, response time, life cycling, evaluation of new processes, features, and new product development. NDT TESTING & MATERIAL ANALYSIS Non-Destructive Testing services that includes x-ray, visual, and Dye Penetrant inspection. ENVIRONMENTAL TESTING Including, but not limited to shock, vibration, salt spray, humidity, high (1000 F) and low (-150 F) temps, altitude to 100,000 feet, and other testing as required. HYDRAULIC TESTING Up to 75HP, 60,000 PSI PACKAGING Commercial, military, environmental storage, custom, VPCI, and returnable packaging and cleaning. MANUFACTURING ENGINEERING In-house Tool/Machine design and build capabilities. CNC WINDING MACHINES, COMPUTER AUTOMATED TEST STANDS Reduces manual testing time and cost and eliminates operator error. CNC MACHINES Multi-axis, vertical and horizontal turning and milling as well as automatic manufacturing cells. SCREW MACHINES Six spindle, eight spindle chucking and bar. WELDING/BRAZING Electron beam, gas tungsten arc welding, laser, induction, heliarc, spot welding, and brazing. PLATING Cadmium, zinc, electroless nickel, zinc phosphate, chemical film on aluminum, anodize, passivate, Zinc Nickel and others. PRESSURE MOLDING Transfer and injection coil overmolding. INTERNATIONAL STANDARDS Meets or exceeds many international certification standards.

PRODUCTS MARKETS Aerospace Defense Solenoids Solenoid Valves Engine Management Off Highway Sensors (LVDT) Flame Arrestors Oil & Gas DEDICATED TO CONTINUOUS IMPROVEMENT AND TOTAL CUSTOMER SATISFACTION. Our investment in equipment and facilities is just part of our commitment to customer satisfaction. We also demonstrate it through the use of statistical process controls, Lean Manufacturing programs and continuous personnel and supplier training. It is this level of dedication and investment that makes LISK a global leader in the design and manufacture of Solenoids, Solenoid Valves, Sensors (LVDT) and Flame Arrestors. LISK. ACTIVATING THE WORLD. Industrial Power Generation Medical www.gwlisk.com Headquarters and Manufacturing Facility G.W. Lisk Company, Inc. 2 South Street Clifton Springs, New York 14432 USA Phone: 315-462-2611 Fax: 315-462-7661 E-mail: sales@gwlisk.com European Manufacturing Lisk Ireland Limited Ennis Road, Gort, County Galway Republic of Ireland Phone: 353-91-631711 Fax: 353-91-633011 E-mail: sales@gwlisk.ie Asia Sales and Manufacturing Lisk Control Technology Co., LTD Suzhou Industrial Park (SIP) No.9, Hongfeng Road Jiangsu, P.R. China 215021 Phone: 86-512-62990128 Fax: 86-512-62990129 E-mail: sales@gwlisk.com