WIRELESS WEATHER STATION C-8136

Similar documents
WIRELESS WEATHER STATION WIRELESS WEATHER STATION. Please Note. We are unable to supply Additional Sensors for This Weather Station C-8105/C-8145

LONG-RANGE WIRELESS WEATHER STATION WITH IN-OUT THERMO-HYGROMETER AND RF CLOCK

Weather Forecast RF Wall Clock with Romote Thermometer Model: JMR818WF. User Manual

INSTRUCTION MANUAL TRC-1490 Wireless Indoor and Outdoor Weather Station

WEATHER FORECASTER WITH IN/OUT THERMO RADIO-CONTROLLED COLOR PROJECTION CLOCK - Ref.: RPM OWNER S MANUAL -

MOONPHASE WALL CLOCK Instruction Manual

WS INSTRUCTION MANUAL LED WEATHER STATION WITH RADIO CONTROLLED CLOCK AND ALARM

WIRELESS 868 MHz TEMPERATURE STATION Instruction Manual

MOONPHASE WALL CLOCK Instruction Manual

Weather System Pro Model: BAR629HG / BAR629HGU User Manual

Cable Free Weather Station with Thermo-Hygrometer and Radio controlled clock

DIGITAL WEATHER FORECASTER WITH REMOTE THERMO-HYGRO SENSOR AND RADIO CONTROLLED CLOCK

COLOUR WEATHER STATION MODEL: AWS888N USER S MANUAL

Wireless Weather Station Model: BAR826HG

Wide-Screen Weather Forecast RF Clock with Thermometer Model: JM828WF / JM828WFU. User Manual

WIRELESS RAIN GAUGE WITH IN/OUT TEMPERATURE INSTRUCTION MANUAL

WIRELESS COLOR WEATHER STATION

Weather Station with 433MHz Thermo-Hygrometer and Radio Controlled Clock Model: 888R25 USER S MANUAL

Ambient Weather RC-8365 ClearView Radio Controlled Projection Clock with Indoor and Outdoor Temperature User Manual

CONTENTS. La Crosse Technology, Ltd. Page 1

Ambient Weather RC-8365 ClearView Radio Controlled Projection Clock with Indoor Temperature User Manual

Power Requirements... 9

WIRELESS COLOR WEATHER STATION

INTRODUCTION CONTENTS

INSTRUCTION MANUAL WT 498S Radio Controlled Alarm Clock with Temperature and Calendar

Weather Station with Remote Control Model: BAR289

Multi-Channel IN-OUT Thermo-Hygrometer with Cable Free Sensor and RF Clock

Weather Station Advanced Model: BAR628HG / BAR628HGU User Manual

Atomic Alarm Clock Instruction Manual

WEATHER STATION WITH CABLE FREE IN-OUT THERMOMETER UV MEASUREMET AND IN-OUT HYGROMETER MOONPHASE AND RADIO CONTROLLED CLOCK (SWISS SIGNAL HBG )

CONTENTS. La Crosse Technology, Ltd Page 1

Weather Light Model: BAR210 / BAR210U / BAR210A USER MANUAL. EU-Declaration of Conformity...7 FCC Statement...7 Declaration of Conformity...

433 MHz RADIO CONTROLLED PROJECTION ALARM CLOCK Instruction manual

RGR150 USER S MANUAL. Wireless Rain Gauge with Thermometer and Clock

WIRELESS COLOR FORECAST STATION

SUN CLOCK In structions Manual

Model: M Instruction Manual DC: WIRELESS COLOR WEATHER STATION Mold Risk for Weather Station & Indoor Remote Sensor Location

WS-8117U-IT RADIO-CONTROLLED CLOCK WITH WIRELESS OUTDOOR TEMPERATURE AND MOON PHASE Quick setup manual

V4 FAQS CONTENTS

+ECO Solar Weather Clock Model: BAR332ES / BAR332ESA / BAR332ESU USER MANUAL CONTENTS

CONTENTS. La Crosse Technology, Ltd Page 1

CONTENTS. La Crosse Technology, Ltd. Page 1

WIRELESS RAIN GAUGE WITH IN/OUT TEMPERATURE INSTRUCTION MANUAL 1. INTRODUCTION 2 2. INSTALLATION 2

Atomic Digital Clock Model: Instruction Manual

Desktop Dual-band Radio Controlled Clock with Melody Alarm and Backlight Model: RM926 User Manual

Color Forecast Station. Table of Contents

High Precision Digital Rain Gauge with Indoor Temperature and Humidity

Wireless Weather Station with Solar Transmitter Instruction Manual

WS WEATHER STATION

RF Projection Clock Model: RM939P POLERMO Projection Clock Model: RM939PA

Operating Instructions

Operation Manual Professional Remote Weather Station

4-Day Weather Forecaster Station Model: WMH601

Multi-Channel Indoor-Ooutdoor Thermohygrometer with Cable Free TM Sensor & ExactSet TM Clock

WEATHER PROJECTION STATION Instruction Manual

Operation Manual Professional Remote Weather Station

WIRELESS COLOR FORECAST STATION

Ambient Weather RC-8487 ClearView Radio Controlled Travel Alarm Clock with Indoor Temperature User Manual

Weather Station with Remote Color Changing Light Box Model: BAR989HG / BAR989HGA USER MANUAL

CONTENTS. Batteries. La Crosse Technology, Ltd Page 1

COLOR WEATHER STATION. Item No Owner s Guide

V2 FAQS CONTENTS

MULTI-CHANNEL IN-OUT CABLE FREE THERMO-HYGROMETER

Operation Manual 1. Introduction Professional Remote Weather Station

WIRELESS FORECAST STATION

Honeywell. Weather Forecaster with Dual Projection (PCR426W) USER MANUAL TABLE OF CONTENTS INTRODUCTION 3 PRODUCT OVERVIEW. Error!

Operation Guide DQR-200

+ECO Solar Clock Model: RMR331ES / RMR331ESU / RMR331ESA USER MANUAL CONTENTS

Model: B Instruction Manual DC: WIRELESS COLOR WEATHER STATION

Model: S88907 Instruction Manual DC: WIRELESS COLOR WEATHER STATION

Wireless Color Weather Station

Digital Thermometer with Ice Alert and Radio-Controlled Clock. Model: RMR382 USER MANUAL CONTENTS

Digital Thermometer with Ice Alert and Radio-Controlled Clock Model: RMR682

Ambient Weather RC-8419 ClearView Radio Controlled Projection Alarm Clock with Indoor Temperature User Manual

WIRELESS MULTI-ZONE DIGITAL THERMOMETER WITH RADIO CONTROLLED CLOCK. Model No (SF Version) Instruction Manual

Wireless Color Forecast Station

DIGITAL ATOMIC WALL CLOCK

C F AQ S C85183 FAQS AC Power Batteries Atomic Alarm Clock Factory Restart Atomic Alarm Clock AC Power Batteries Explanation:

Model: v2 Quick Setup Guide DC: Atomic Projection Alarm with Indoor and Outdoor Temperature

WS-8117U-IT ATOMIC CLOCK WITH OUTDOOR WIRELESS TEMPERATURE AND MOON PHASE Instruction Manual

Ambient Weather WS-0211 Wireless Wendy the Weather Wizard User Manual

Ambient Weather RC-9362 Atomic Digital Wall Clock with Temperature User Manual

Model: T83653v2 Instruction manual DC: WIRELESS COLOR FORECAST STATION Mold Risk for Forecast Station & Indoor Remote Sensor Location

Honeywell Barometric Weather Forecaster (TE653ELW) USER MANUAL TABLE OF CONTENTS INTRODUCTION 3 STANDARD PACKAGE CONTENTS 3 BEFORE YOU BEGIN 4

Model: A Quick Setup Guide DC: Atomic Projection Alarm Clock

Multi-Channel Indoor & Outdoor Thermometer with Cable Free Sensor & Radio Controlled Clock

Model: Av2 Quick Setup Guide DC: Atomic Projection Alarm Clock

Atomic Projection Alarm Clock

Model: C Instruction Manual DC: WIRELESS COLOR WEATHER STATION

Wireless In/Out Thermometer with Atomic Clock

Model: WS-9133U-IT Quick Setup Guide DC: WIRELESS FORECAST STATION

Water Tank Level Monitor

Ambient Weather WS-16 8-Channel Wireless Thermometer with Min/Max Display User Manual

Ambient Weather WS Channel Wireless Thermometer with Min/Max Display User Manual

EN Oregon Scientific Radio-Controlled Projection Clock (RM816P / RM816PU / RM816PUL) User Manual

Model: Quick Setup Guide DC: Atomic Projection Alarm Clock. Projection Lens. Buttons. Snooze/Backlight

Wireless Humidity/ Temperature Monitor Remote Wireless Sensor

Weather Day & Night Model: BAR339DP / BAR339DPA / BAR339DPU / BAA339DPH

ATOMIC DIGITAL CLOCK. Time and Alarm

F AQ S FAQS Projection Alarm Factory Restart Outdoor Temperature Sensor Batteries Projection Alarm

Transcription:

C-8136 AMD C-8136 ADDD, C-8136AWD LCD-329 (US) LCD-330(EUROPE) WIRELESS WEATHER STATION C-8136 USER S INSTRUCTIONS Part NO: P17813600010

The multifunctional weather station is equipped with many functions providing thorough weather information to you. The receiver unit has a clear, easy-to-read display that shows weather forecast, indoor temperature pressure, time and date, as well as the temperature measured and transmitted by the sensor. It is able to receive and display readings from remote sensor. The 433 MHz technology means no wire installation is required and you can place the sensor anywhere you like. With radio controlled function, the current time and date are automatically synchronized with the time signal transmitted from Frankfurt, Germany (DCF77) / UK (MSF) / US (WWVB). It depends on which version you purchase The signal can cover a distance of about 1500 km from the related transmitter. REMOTE SENSOR Our Temperature measuring range: -20 ºC to +60 ºC Recommended operating range: -20 ºC to +55 ºC Temperature resolution: 0.1 ºC / 1ºF (above 0 ºC) 1 ºC / ºF (below 0 ºC) RF transmission frequency: 433MHz No of remote unit: 1 unit RF transmission range: Maximum 30 meters Temperature sensing cycle: around 60 ~ 64 seconds Pressure measuring range: Pressure sampling cycle: 800mb to 1050mb 15 minutes Radio controlled signal: DCF77,MSF,WWVB Power: Main unit: 4.5 V, use 3 x AAA 1.5V alkaline battery Remote sensor: 3 V, use 2 x AAA 1.5V alkaline battery Weight Main unit: 265gm Remote sensor: 53gm Dimension Main unit: Remote sensor: 196(W)x129(H)x 22(D)mm 65(W)x93(H)x 27(D)mm p. 1 p. 18

MAIN FEATURES: WEATHTER STATION: 1 2 3 4 5 13 12 11 10 9 8 7 6 SPECIFICATIONS MAIN UNIT Indoor temperature measuring range: -5 ºC to +50 ºC Recommended operating range: 0 ºC to +45 ºC Temperature resolution: 0.1 ºC / 1ºF (above 0 ºC) 1 ºC / ºF (below 0 ºC) 14 15 p. 17 p. 2

1. CLOCK : - Displays the time and radio controlled signal. 2. CALENDAR : - Displays the date, year, day of the week. 3. OUTDOOR AND INDOOR TEMPERATURE WINDOW: - Shows the outdoor and indoor temperature. 4. ATMOSPHERE PRESSURE : - Displays the current atmospheric pressure data. 5. WEATHER FORECAST : - Displays the weather forecast indicator. 6. TABLE STAND: - Use to stand on desktop. 7. SNOOZE : - Press it to stop alarm when it is sounding. 8. TIME: - Press it once to view the year. - Press and hold it for 2 seconds to enter the time setting mode. Transmitter s low battery indicator Transmitter s low battery indicator ( shows on transmitter ) ( shows on the main unit) CH Atention should be drawn to the environment aspects of battery disposal USING THE TABLE STAND OR WALL MOUTING The receiver has both desk-top and wall-mounting structure. Fix the separate wall-mounting stand on the wall by screws. Push the stand of the clock upward, hang it on the wall-mounting stand by its recessed holes. For the transmitter, fix the wall-mount holder on the wall or simply place it on the table. 9. DOWN: -In setting mode, press it to decrease the setting value. - In alarm mode, press it to turn on/off alarm and snooze. p. 3 p. 16

Slightly cloudy Cloudy Rainy 10. UP: - In setting mode, press it to increase the setting value. - In alarm mode, press it to turn on/off alarm and snooze. Snow Sunny 11. ALARM: - Press it to switch to alarm and temperature alarm. - In alarm mode, press and hold it for 2 seconds to enter the alarm and pre-alarm setting mode. 12. ºC / ºF: - Switch between ºC / ºF. 13. mb/hpa. inhg: - Switch between mb/hpa or inhg. 14. RESET: - Press it to set all of the values to factory value. - In case of mal-function, the unit may be required to reset. LOW BATTERY INDICATOR 15. WALL-MOUNTING HOLE: - Use to support the main unit on wall. When the battery does not have enough power to operate the unit, The Receiver s LCD becomes dim, and the transmitter s low battery indicator will appear to remind you to replace with new batteries. p. 15 p. 4

TRANSMITTER: To activate pre-alarm function, ALARM must be on. Temperature alarm ON Pre-alarm mode Pre-alarm 15 minutes 1 2 3 4 5 6 WEATHER FORECAST 7 The built-in barometer can notice atmospheric pressure changes. Based on the data collected, it can predict the weather condition in the forthcoming 12-24 hours. The effective range covers area of about 30 to 50 km 8 1. The accuracy of a general pressure-based weather forecast is about 70 to 75%, and therefore, cannot be held responsible for any inconveniences caused by an inaccurate data. 2. The weather forecast is meant for next 12 to 24 hours. It may not necessarily reflect the current situation. 3. The Sunny icon, when applies to nighttime, implies clear weather. p. 5 p. 14

1. The alarm will automatically turn on when setting the alarm time. 2. Once the snooze is turn on, the 4-step crescendo alarm will sound 4 times in 5-minute interval. The alarm duration is 120 seconds. Alarm OFF Alarm ON Alarm and Snooze ON 1. LED indicator: - Flashes when the remote unit transmits a reading. 2. LCD: - Displays the current temperature monitored by the remote unit. 3. ºC / ºF: - Switches between ºC / ºF. 4. RESET: - Return all values to default value. SETTING THE TEMPERATURE ALARM Use this function to be woken up at a determined period of time earlier (1-90 minutes), if the transmitter s temperatures is below -3ºC. 1. In normal time mode, press ALARM key twice to enter pre-alarm mode, press UP or DOWN key to turn pre-alarm on. 2. Press and hold the ALARM key for 2 seconds, pre-alarm time flashing, press UP or DOWN key to change its value. 5. Battery compartment: - Accommodates 2 AAA size batteries. 6. Battery door 7. Wall mount holder: - Supports the transmitter in wall mounting. 8. Folding table stand p. 13 p. 6

BEFORE YOU BEGIN TRANSMITTER: 1. Remove the removable stand, unscrew the screws of the back cover and lift the cover off. 2. Insert 2 x AAA batteries into the battery compartment. Be sure to insert them the right way round (see polarity information +/- in the battery compartment). 3. Select the temperature unit by sliding the ºC / ºF switch besides the battery compartment. 4. Re-fix the battery door, and secure its screws in evenly and diagonally. Avoid placing the transmitter in direct sunlight, rain or snow. WEATHER STATION: 1. Remove the battery door and insert 3 x AAA batteries into the battery compartment. Make sure you insert the batteries the right way round (see polarity information +/- in the battery compartment). 2. Close the battery compartment. 3. Press reset button to re-start the clock and it will synchronize with the transmitter automatically. p. 7 manually. As soon as the transmitter is received again, the clock will automatically synchronise with the received time. 1. In normal time mode, press and hold TIME key for 2 seconds, hour flashing, press UP or DOWN key to change its value. 2. Press TIME key again, minute flashing, press UP or DOWN key to change its value. 3. Repeat the above operation to set the time in this order: Hour - Minute - Second - 12/24 hour - Year - Month - Date 4. After setting completed, press TIME key to exit setting mode, or let it exit automatically in 30 seconds without pressing any key. ALARM AND SNOOZE SETTING 1. In normal time mode, press ALARM key once to enter the alarm mode. Press UP or DOWN key once, alarm is on with the bell indicator displayed. Press UP or DOWN key again to turn on SNOOZE with Zz displayed. Press UP or DOWN key to turn off ALARM and SNOOZE. 2. In normal mode or alarm mode, press and hold ALARM key for 2 seconds, hour flashing. Press UP or DOWN key to set the value. Repeat the same operation to set the alarm minute. 3. After setting completed, press ALARM key to return to normal mode, or let it exit automatically 30 seconds later without pressing any key. p. 12

2. Always place the unit away from interfering sources such as TV set, computer, etc. 3. Avoid placing the unit on or next to metal plate. 4. Closed area such as airport, basement, tower block or factory is not recommended. 5. Do not start reception on a moving article such as vehicle or train. 1. The building material and the position of the receiver and transmitter affect the effective range. So try various locations will help to obtain the best result. 2. Place the units away from metal objects and electrical appliances to minimize the interference. Position the receiver and the transmitter within effective transmission range: 30 meters in usual circumstances. ABOUT THE WEATHER INDICATOR SELECT THE TIME ZONE (FOR WWVB VERSION ONLY) The default time Zone is PACIFIC Zone, if your location is out of Pacific, set the time zone as the following: In normal time mode, press DOWN button to change it: 1. The default weather indicator is slightly cloudy. After inserting the batteries, the unit will automatically predict the weather condition in the forthcoming 12-24 hours. It will change its weather indicator according to the predicted data once it completes predicting. 2. There are 5 weather indicators the unit can show as the following: P=Pacific M=Mountain C=Central E=Eastern MANUAL TIME SETTING If you are out of the reach of the Radio Controlled Tranmsitter or if the reception is not reachable, the time can be set p. 11 p. 8

Slightly cloudy Cloudy RECEPTION OF RADIO CONTROLLED TIME SIGNAL The time and date are radio-controlled. The current time and date are automatically synchronized with the time signal transmitted from Frankfurt, Germany (DCF77), UK/ (MSF) / US (WWVB) provided the device is within about of 1500 km range of the transmitter. When used for the first time (after inserting the batteries or pressing RESET), the clock starts receiving time signals and the reception display flashes. SIGNAL STRENGTH INDICATOR Rainy Snow Sunny The signal indicator displays signal strength in 3 levels. Wave segment flashing means time signals are being received. The signal quality could be classified into three types: 1. Everyday the unit will automatically search for the time signal at 2:00, 8:00, 14:00 and 20:00. p. 9 p. 10