MIST FIRES AND EXPLOSIONS: FACT OR MYTH? Introduction

Similar documents
POSITION PAPER ON WATER MIST FOR FIRE FIGHTING APPLICATIONS

Handling Petroleum Products & Static Ignition Hazards Introduction

VAPOUR RECOVERY DURING FUEL LOADING. Ben Adamson Principal Engineer Refrigeration Engineering Pty Ltd, NSW Australia

Dust Explosion Hazard Overview

Learning From Risk Control System Failures. Mike Jones

RE: USE OF FIREPRO IN POTENTIALLY EXPLOSIVE ATMOSPHERES

DIRECTIVE NO: D-B

WHAT WHITE PAPER IS POTENTIALLY EXPLOSIVE ATMOSPHERE CERTIFICATION AND WHY YOU. June 2010

Understanding. Combustible Dust Hazards: Basic Measures to Ensure the Safety of Combustible Dust Handling Operations

Explosion Protection Engineering Principles

Unit 6: Fire Investigation

Making sense of risk Risk engineering. Metalworking operations

CLASSIFICATION NOTES. Type Testing Procedure for. Crankcase Oil Mist Detection and Alarm Equipment

C 319/6 Official Journal of the European Union

DUST EXPLOSION CODES AND STANDARDS: Ensuring Regional Compliance and Global Consistency

(Publication of titles and references of harmonised standards under Union harmonisation legislation) (Text with EEA relevance) (2015/C 335/02)

International Safety Guide Chapter 30 for Inland Navigation Tank-barges and Terminals. Chapter 30 FIRE-FIGHTING

Flammable and Combustible Liquids

Dust Explosions. by Clive de Salis. Telephone: +44 (0)

ADDITIONS TO NFPA 61, STANDARD FOR THE PREVENTION OF FIRES AND DUST EXPLOSIONS IN THE AGRICULTURAL AND FOOD PROCESSING INDUSTRIES

HAZARDOUS AREA CLASSIFICATION AND SELECTION OF EQUIPMENT FOR SAFE USE THEREIN FROM AN ELECTRICAL VIEWPOINT

The Protection of Machinery Spaces by means of the Local Application of Water Mist. Dr. Tim R. Nichols CPhys FIFireE

Exhaust Duct Design Page 1 of (C)

PRIMATECH WHITE PAPER PROCEDURE FOR DUST HAZARD ANALYSIS (DHA)

IFE Level 4 Certificate in Fire Science and Fire Safety

(Publication of titles and references of harmonised standards under Union harmonisation legislation) (Text with EEA relevance) (2016/C 126/02)

(Notices) NOTICES FROM EUROPEAN UNION INSTITUTIONS, BODIES, OFFICES AND AGENCIES EUROPEAN COMMISSION

Fixed plant and mobile equipment fires on surface coal mines

Introduction. Program Description. Section C.20 University of South Carolina Safety Program Guide FLAMMABLE AND COMBUSTIBLE LIQUIDS

COMBUSTIBLE DUST SAFETY PROGRAM

Conducting a NFPA 652 Dust Hazard Analysis (DHA): Practical Tips & Approaches

AUTOMATIC FIRE SUPPRESSION SYSTEMS

Seat Ventilation offers an extensive range of ATEX certified products and is undertaking great efforts to extend this range even further.

Official Journal of the European Union

(Notices) NOTICES FROM EUROPEAN UNION INSTITUTIONS, BODIES, OFFICES AND AGENCIES EUROPEAN COMMISSION

Ontario Fire Code SECTION 5.10 COMBUSTIBLE DUST PRODUCING PROCESSES. Illustrated Commentary. Office of the Ontario Fire Marshal

NILEATOR ATOR. Dyna-Fog ANILE. Cold Fog ULV Aerosol Applicator. Instruction Manual For Operation, Service and Maintenance

Fire Department HEADQUARTERS Cathedral Oaks Road Santa Barbara, CA (805) FAX: (805) CODE SUMMARY

Matters Needing Attention of Electrical Equipment Installation Engineering in Hazardous Areas. Wang Qiaoli

AS AS Australian Standard. Industrial fuel-fired appliances. This is a free 9 page sample. Access the full version online.

ISO INTERNATIONAL STANDARD. Hydrogen generators using fuel processing technologies Part 1: Safety

VERIFICATION OF AN AEROSOL LEAK DETECTOR FOR THE ALTERNATIVE TO THE WATERBATH METHOD FOR RAUPACK LIMITED

Combustible Dust Hazard Recognition and Control NFPA Standards for Combustible Dusts

Failure to follow these instructions could result in fire or explosion which could cause property damage, personal injury or death.

WATER MIST FIRE PROTECTION SYSTEMS FOR INDUSTRIAL CABLE TUNNELS AND TURBINE HALLS

INTRODUCTION TO DUSTS AND THEIR EXPLOSIVE PROPERTIES

(Publication of titles and references of harmonised standards under Union harmonisation legislation) (Text with EEA relevance) (2018/C 092/02)

WAS STARTED BY CARLOS BAHAMONDES MASAFIERRO

AS/NZS 4745:2012. Code of practice for handling combustible dusts AS/NZS 4745:2012. Australian/New Zealand Standard. Superseding AS/NZS 4745:2004

STANDARDS FOR VAPOUR EMISSION CONTROL SYSTEMS ( MARPOL reg VI/15 )

Impact of quick incident detection on safety in terms of ventilation response

Smoke detection in hazardous areas:

DMP & RISK MANAGEMENT PLAN

Implementation of ATEX Guidelines

Dust Explosions. health & environmental sciences failure analysis & prevention

Fire protection on chemical manufacturing sites

Hazardous Material Safety Program

Recommendations for a Model Curriculum for a BS Degree in Fire Protection Engineering (FPE) April 15, 2010

IMPERIAL CHEMICAL INDUSTRIES LIMITED PETROCHEMICALS DIVISION. SAFETY NEWSLETTER No. 52

Safe working with flammable substances

ICHEME SYMPOSIUM SERIES NO. 144 A METHODOLOGY FOR ASSESSING AND MINIMISING THE RISKS ASSOCIATED WITH FIREWATER RUN-OFF ON OLDER MANUFACTURING PLANTS

TYPE TESTING PROCEDURE FOR CRANKCASE EXPLOSION RELIEF VALVES JULY 2016

Combustible Dust Booklet

Identifying and Preventing Dust Fire and Explosion Hazards

NFPA 33 Standard for Spray Applica4on Using Flammable or Combus4ble Materials

Explosion protection Marijan Gorše, dipl. ing.

Patio Heater Model No. GM and GM

APPLICATION BULLETIN COMBUSTION TURBINE FACILITIES. Overview

Safety Policy and Procedure

Beamex Calibration White Paper. Calibration in hazardous areas

Explosion at Battery Site Date of Incident: Type of Incident: Fatal

Report from the Division for Investigation of Maritime Accidents

Official Journal of the European Union

DIESEL SPACE HEATER, DIESEL TYPE 30KW CT2142. Instruction & Assembly SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE

Aluminum Dust Management in a Metallizing Facility

Guidance Note. Guidance Document on Best Practice for Fire Detector Testing/Test Equipment

Vancouver Airport Fuel Delivery Project. Fire Prevention, Preparedness and Emergency Response

MB05. RESPOND TO EMERGENCIES BASIC KNOWLEDGE OF EMERGENCY PROCEDURES, INCLUDING EMERGENCY SHUTDOWN

The first tunnel fire. Benefits of fire

HYDROCARBONENGINEERING June June 2015

A: RS-45 is a non ozone depleting Drop-in replacement for R22 in most applications. A: RS-45 is a blend of R143a, R125, R134a and isobutane.

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 350 SERIES CIRCULATION HEATERS

This policy applies to all Hot Work jobs performed on the Calhoun mill property by AbitibiAbitibiBowater employees.

Before proceeding with the selection process, let s briefly look at the various explosion protection options:

Title: Fire Protection Effective Date: 7/1/2013 Control Number: THG_0039 Revision Number: 1 Date: 10/23/2015 Annual Review Completed: 5/13/2015

FOR YOUR SAFETY FOR OUTDOOR USE ONLY PROPANE GAS. Model No. AH2069ODS, AH2063ODS

Objectives. NFPA Dust Specific Documents. Combustible Dust Process Hazard Safety Overview of NFPA Standards for Combustible Dusts

IECEx Certification of Dust Collection System Assembly. IECEx 2018 International Conference Split, Croatia 23 rd April 2018

An Oven Explosion Lessons Learned on PSM Concepts (or PSM: It s not just for breakfast anymore )

Beamex. Calibration White Paper. Calibration in hazardous areas

AVOID CATASTROPHIC SITUATIONS: EXPERT FIRE AND GAS CONSULTANCY OPTIMIZES SAFETY

Protecting Facilities Against Explosions. Since 1956

Retrospective Hazard Review

model No: ir20.v2 FUSE

Legislation associated with Hazardous Locations. Pieter Coetzee ZONE 2 ZONE 1 ZONE 0. Be safe be Ex

WATER MIST CONVENTION AND EXHIBITION

Ex Products Highest level of safety under the most difficult conditions

AVOID CATASTROPHIC SITUATIONS: EXPERT FIRE AND GAS CONSULTANCY OPTIMIZES SAFETY

Test procedure/ method name. method identification. Testing of industrial and explosion isolation valves and tank lining

IRceL CH4 Methane (CH 4

Transcription:

MIST FIRES AND EXPLOSIONS: FACT OR MYTH? Nigel Allen Senior Process Safety Specialist UKELG meeting, 9 th September 2009 2009 Introduction In this presentation I will answer the title question by quoting examples of fires and explosions involving flammable mists. I will also give ideas on how to assess where flammable mists could occur and how to control them. References will be quoted where applicable. The opinions quoted are those of the presenter, and not necessarily those of as a whole. Mist Fires and Explosions: fact or myth? 1

Chilworth Technology- what we do Process Safety Risk Management Environmental Consultancy Laboratory Testing In company Training Instrumentation Example of mists from nature Mist Fires and Explosions: fact or myth? 2

Historical Mist fires and explosions have been recognised a possibility for many years. As long ago as 1955, Eichhorn published an article in the Petroleum Refiner on the subject, entitled Careful! Mist can explode. His article introduced the concept of a mist flammable range at temperatures below those on the dew point (saturated vapour) curve for a liquid. Flammability diagram at a fixed pressure Mist Fires and Explosions: fact or myth? 3

Are mist fires and explosions a fact? Yes, is the answer! One common cause: Liquids are sprayed from a nozzle at high momentum onto a liquid or solid surface; Causes droplet break up and the creation of a fine mist, which may be electrostatic charged. Mist fires and explosions can also be caused by liquid leaks under pressure. Flammable mists can also form when hot vapours are suddenly cooled ref. crank case explosions in marine diesel engines. Incidents due to liquid spraying Liquid spraying has caused explosions. The liquid does not have to be above its flash point for this to occur, and the consequences can be tragic: A road contractor s employee received fatal burns in 2003 while cleaning a bitumen tanker using a spray of mixed gas oil and kerosene. The HSE investigation concluded that static electricity was a possible cause, though other ignition sources such as smoking and hot work were not effectively controlled. The company concerned had not learned from the past. Kerosene spraying of aviation tanks had killed three men over 20 years earlier. Mist Fires and Explosions: fact or myth? 4

Electrostatics guidance Electrostatics guidance (e.g. CLC/TR 50404:2003) recognises that high pressure jets can create charged mists. It therefore recommends that spraying using hydrocarbon solvents is only acceptable if: The spray pressure is less than 50 barg. The container being sprayed has a volume of less that 5000 litres. The liquid throughput is less than 1 litre/sec. It is also recommended that conducting and static dissipative objects, including people, are earthed. Incidents involving liquid leaks Evidence suggests that the formation of aerosols from leaking heat transfer fluids have contributed to several explosions e.g. Factory Mutual Research report published at AIChE Loss Prevention Symposium in 1995. One possible example (from Loss Prevention Bulletin): A leak of heat transfer fluid from a 12 mm orifice at 4 barg and 300 C led to the formation of a mist cloud, possibly through a combination of spraying and vapour cooling. Ignition occurred when a flameproof light was damaged when a water deluge system caused the protective glass to rapidly cool and crack. Mist Fires and Explosions: fact or myth? 5

Two minor incidents investigated by Chilworth Technology Road tanker was offloading high flash point (FP > 100 C) printing inks to customer storage tanks. Offloading was carried out using the tanker s pump so hose was under pressure. Poorly made hose connection led to the formation of a small mist cloud at the coupling, which then ignited. Small fire was quickly extinguished. Offloading continued, but a subsequent (internal) fire occurred when the hose coupling was loosened to clear using the tanker pump after offloading was complete. Cause of the fires Hydraulic supply to offloading pump Road tanker Discharge hose may have been electrically live Mains supply to hydraulic pump with poor earth Leaking joint where fire occurred Mist Fires and Explosions: fact or myth? 6

Condensation mists- Examples from the marine industry Explosions in in marine diesel engine crankcases have been attributed to hot bearings or other components where oil vaporises, which then cools to form a mist when it moves away from the heated area. Numerous fires and explosions have occurred (14 were recorded between 1995 and 2002). Some of these had fatal consequences, particularly when the explosion propagated into the engine room. Crankcases are now fitted with relief valves with flame arresters to guard against internal explosions propagating into the engine room, but preventative maintenance, careful installation and use of approved parts is also recommended. Condensation mists: 1986 fryer explosion Mist Fires and Explosions: fact or myth? 7

Condensation mists: 1986 fryer explosion From HSE incident. Pollution fan shut down because belt drive was slipping. Burners then tripped out as designed. Smoke then observed coming from combustion chamber so combustion air switched on (to combat smoke), oil was pumped to storage and water then introduced to the fryer. Explosion then occurred. Attributed to air exacerbating the smouldering, air introduced into the fryer by emptying it and water displacing air/mist/vapour mixture into the combustion chamber. Better interlocking systems (e.g. a damper between the fryer and combustion chamber) would have prevented this incident. Could I have a mist fire or explosion? If you deliberately spray combustible liquids or they can condense to form a mist cloud, the default answer should be yes. However, in this case you should consider precautions to, in order of preference: Prevent mist formation e.g. reduce spray velocities. Prevent the formation of a flammable atmosphere (ref. fryers) Control ignition sources. Mitigate the effects of an explosion (ref. marine crankcases). Mist Fires and Explosions: fact or myth? 8

Could I have a mist fire or explosion? The problem I most often encounter is whether or not flammable mists can form due to leaks from oil and other high flash point liquid lines. Evidence suggests that mists do not form at small orifices or at low pressures. For example, 1 barg has been used as a minimum pressure in the past. Therefore, most secondary grade release sources may not lead to flammable mist releases, and hence hazardous area classification may not be required for the mist. Such releases can also be prevented using spray guards. Could a flammable mist form at a release source? A more quantified approach. Use can be made of Lefebvre & Zanelli s correlation to define if a release could atomise or form a second wind-induced spray according to Faeth s definitions. i.e. where Ca > 17.8Z 0.91 Where Ca is the Capillary Number (Weber number divided by the Reynolds number), and Z is the Ohnsorge number. Defining the mean diameter (Sauter Mean Diameter or SMD) of droplets has also been attempted, though note is made of the limitations of, for example, the Elkotb correlation. Mist Fires and Explosions: fact or myth? 9

Notes on hazardous areas What hazardous areas should be defined around sources of flammable mists? I have quoted 1m Zone 2 areas around secondary grade releases (e.g. joints) where spraying is not prevented by, for example, guards or lagging. However, this is purely qualitative. The actual Zone 2 will depend on the lower explosion limit (LEL) of the mist, among other factors. Work in Japan (NIIS-SRR-17) has concluded that this is equivalent to the LEL of the vapour (around 40 g/m 3 for a hydrocarbon) but more recent work has indicated that the actual figure is 50% of the equivalent vapour LEL. Notes on Minimum Ignition Energy (MIE) Another factor is whether or not a mist cloud could be ignited by an ignition source: Work by Singh and Polymeropolous quoted in Bowen s 1994 paper suggests that spark energies of down to 3-4 mj can ignite aerosols with a droplet diameter of 20-30 µm. More recent work in Japan (NIIS-SRR-17) has found that alkane aerosols with a flash point above ambient temperature typically have an MIE of 4 mj. This appears to concur with the earlier work. Otherwise, mists are as sensitive as the equivalent gas or vapour. This would indicate that brush electrostatic discharges are incapable of igniting flammable mist atmospheres. Mist Fires and Explosions: fact or myth? 10

Conclusion Flammable mist fires and explosions are a fact. They can occur if mists are formed from spraying under pressure or condensation. Mist fires and explosions have sometimes had fatal consequences, and hence the phenomenon needs to be given serious consideration. Simple measures can sometimes be taken to prevent, control or mitigate against mist explosions. Methods are available to estimate where a flammable mist atmosphere could occur. However, it still appears difficult to determine what the extent of such an atmosphere could be. Mist Fires and Explosions: fact or myth? 11