MERIT SERIES Up Flow / Horizontal

Similar documents
MERIT Series R-410A - Upflow / Horizontal

MERIT Series R-410A - Upflow / Horizontal

CB18/CBS18 Bulletin # September 1994 Supersedes August 1986

B24/C22/24 COILS BLOWER COIL UNITS ENGINEERING DATA. Bulletin # June 1994 Supersedes August B24 Blower Unit (With Optional Electric Heat)

DRY CHARGE UNITS. 1.5 to 5 Tons AIR CONDITIONERS LCS13DC PRODUCT SPECIFICATIONS L C S 13 DC MODEL NUMBER IDENTIFICATION

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,500 to 59,000 Btuh AIR CONDITIONERS 13ACXN PRODUCT SPECIFICATIONS

CB X 32 mv

DAVE LENNOX SIGNATURE COLLECTION R-410A Ready - Multi-Position - Variable Speed

T-SERIES SPLIT SYSTEM UNITS R-410A - 60 HZ. EER up to to 20 Tons Cooling Capacity - 71,000 to 236,000 Btuh AIR CONDITIONERS TS

C22 Bulletin # October 1993 Supersedes May 1993

DAVE LENNOX SIGNATURE COLLECTION R-410A Ready - Multi-Position - Variable Speed

DAVE LENNOX SIGNATURE COLLECTION R-410A Ready - Multi-Position - Variable Speed

13 GEP A L P - 1 A

3 to 5 Tons. AIR CONDITIONERS 2scu13. Dry Charge Split System - 60 HZ PRODUCT SPECIFICATIONS. 2 scu 13 lc 1 36 t - 1 a MODEL NUMBER IDENTIFICATION

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION

DRY CHARGE UNITS. 1.5 to 5 Tons. HEAT PUMP OUTDOOR UNITS lps13dc PRODUCT SPECIFICATIONS L P S 13 DC MODEL NUMBER IDENTIFICATION

C22FC Bulletin # October 1993 Supersedes May 1993

ELITE Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,800 to 60,000 Btuh AIR CONDITIONERS EL16XC1 PRODUCT SPECIFICATIONS

Nominal Capacity 024 = 7 kw (2 tons) 036 = 10.5 kw (3 tons) 048 = 14 kw (4 tons) 060 = 17.5 kw (5 tons)

IMPORTANT CB26UH CBX26UH. Service Literature. CB26UH and CBX26UH Series Table of Contents. Model Number Information... 2

T P A 120 S 4 S N 1 Y

14 AC x

2 shp 13 lc 1 36 t - 1 a

RGE 13 A T - 1 A

14HPX MERIT SERIES R 410A H E A T P U M P O U T D O O R U N I T S

XC16. ELITE SERIES R 410A Two Stage Compressor SilentComfort Technology A I R C O N D I T I O N E R S

Air Handlers and Indoor Coils Up to 20 Tons. CB* and C* Models. True performance and rugged durability

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 18,000 to 60,000 Btuh AIR CONDITIONERS ML14XC1 PRODUCT SPECIFICATIONS

T S A 048 S 4 N 4 1 T

Visit us at For the latest technical information,

MERIT Series R-410A. SEER up to HSPF up to to 5 Tons Cooling Capacity - 18,000 to 61,000 Btuh Heating Capacity - 17,500 to 58,500 Btuh

Specially Designed. SilentComfort Fan Guard. Visit us at For the latest technical information,

13HPD MERIT SERIES R 22 H E A T P U M P O U T D O O R U N I T S

072, 090, 120, 180 & 240 MODELS C SERIES CONDENSING UNITS P SERIES HEAT PUMPS

V8MS Mode Selection Box for VRA Heat Recovery - 60HZ

BCE4 PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER WITH VARIABLE SPEED APPLICATION INSTALLATION CABINET COMPONENTS CONTROLS WARRANTY

Performance and Reliability. CB*, C* and TA* Models

CWA4 Chilled & Hot Water Fan Coil

XC17. DAVE LENNOX SIGNATURE COLLECTION R-410A - SilentComfort Technology. SEER up to to 5 Tons Cooling Capacity - 21,800 to 59,000 Btuh

ELITE SERIES Lo-Boy. AFUE - 83% Heating Input - 101,000 to 151,000 Btuh Nominal Add-on Cooling to 5 Ton. OIL FURNACES El0183b

DAVE LENNOX SIGNATURE COLLECTION WITH SILENTCOMFORT TECHNOLOGY

OHR23. ELITE SERIES Horizontal/Downflow. AFUE - Up to 83.5% Input - 105,000 to 154,000 Btuh Nominal Add-on Cooling - 2 to 5 Tons O HR 23 Q 3/4-105/120

CWA2 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000-60,000 BTUH

LRP14AC. SEER to 5 Tons Cooling Capacity - 22,600 to 57,000 Btuh Optional Electric Heat - 5 to 20 kw. Residential - R-410A

8+* Bulletin No November 1997

LRP14HP. Residential - R-410A L RP 14 HP 36 P A MODEL NUMBER IDENTIFICATION. Bulletin No November 2016 Supersedes October 2016

T P A 048 S 4 N 4 1 T

T-SERIES COMMERCIAL SPLIT SYSTEMS R-410A - 60 HZ

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ. Thermal Efficiency - up to 82% Input - 40,000 to 300,000 Btuh

DUAL ZONE CONTROL PANEL Zone Control For Residential Heating/Cooling Systems

CBX32MV WARNING CAUTION. Service Literature CBX32MV (R410A) SERIES UNITS

WH1T SERIES Constant Torque Motor (ECM) Efficiencies up to 14 SEER. FORM NO. H REV. 1 Supersedes Form No. G Rev. 3

MERIT SERIES Downflow

Gas Valve. Combustion Air Intake. Supply Air Blower AM30. Typical Applications

HIGH EFFICIENCY AIR HANDLER

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION

HIGH EFFICIENCY AIR HANDLER

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH

LRP14GE. SEER AFUE - 81% 2 to 5 Tons Cooling Capacity - 22,600 to 57,000 Btuh Input Gas Heating Capacity - 54,000 to 126,000 Btuh

TECHNICAL SPECIFICATIONS

CBX32MV (HFC-410A) SERIES UNITS

G34M Bulletin #69/ August 2003

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) DESCRIPTION

T CLASS SPLIT SYSTEM UNITS Standard Efficiency R HZ Bulletin No March 2009 Supersedes April 2008

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

TECHNICAL GUIDE HIGH EFFICIENCY, STANDARD ECM VERTICAL WALL MOUNT AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: EWX*18-36

Commercial High-Efficiency Condensing Units

PRODUCT SPECIFICATIONS

HIGH EFFICIENCY TWO-STAGE ECONET ENABLED AIR HANDLER

T CLASS SPLIT SYSTEM UNITS Standard Efficiency - R-410A - 60 HZ

COMPACT UNIT HEATERS Low Profile - Horizontal - 60 HZ. Steady-State Efficiency - up to 81% Input - 30,000 to 75,000 Btuh

Ruud Standard Efficiency Air Handler

Rheem Air Handler. RF1T- Series X-13 (ECM) Motor Efficiencies up to 16 SEER. RF1P- Series PSC Motor Efficiencies up to 14.5 SEER

AIR HANDLERS AIR HANDLERS

AIR HANDLERS AIR HANDLERS RBHP- Models featuring R-22 Refrigerant Models featuring Earth-Friendly R-410A Refrigerant

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

TECHNICAL SPECIFICATIONS B6VMMX

DAVE LENNOX SIGNATURE COLLECTION Lo-Boy - Variable Speed Blower

Rheem High Efficiency Air Handler

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH

Ruud Standard Efficiency Air Handler

ELITE SERIES Downflow - High Efficiency Blower Motor

SKYPAK II Heating & Cooling Self Contained Packages

Ruud Air Handler. RF1T- Series X-13 (ECM) Motor Efficiencies up to 16 SEER. RF1P- Series PSC Motor Efficiencies up to 14.5 SEER

Rheem High Efficiency Two-Stage EcoNet Enabled Air Handler

TECHNICAL SPECIFICATIONS

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series

FF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D

GAS FURNACES G20RE/ G20RXE EXISTING NEG ENGINEERING DATA EXISTING NEG. Typical Applications

INSTALLATION INSTRUCTIONS

MODELS B1PA024, 030 AND 036

GSR21Q PULSE21 SERIES

LRP14DF. Dual-Fuel Residential - R-410A L RP 14 DF X P A MODEL NUMBER IDENTIFICATION

Advance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units

ELITE Series R-410A - Two-Stage Compressor

RetroAire Model Number: 9,000 to 36,000 Btuh (2.6 to 10.5 kw)

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

ACCESSORY KIT INSTALLATION INSTRUCTIONS

Transcription:

A I R H A N D L E R S CB26UH / CBX26UH MERIT SERIES Up Flow / Horizontal E N G I N E E R I N G D A T A Bulletin No. 210429 December 2006 Supersedes November 2006 Nominal Capacity 1.5 to 5 Tons Optional Electric Heat 5 to 20 kw MODEL NUMBER IDENTIFICATION CB X 26 UH 030 230 1 Unit Type CB Air Handler (Blower/Coil) Refrigerant Type X = R 410A (No X = R 22) Series Configuration UH = Up Flow / Horizontal Nominal Cooling Capacity 018 = 1.5 tons 024 = 2 tons 030 = 2.5 tons 036 = 3 tons 042 = 3.5 tons 048 = 4 tons 060 = 5 tons Minor Revision Number Voltage 230 = 208/230V 1phase 60hz

FEATURES CONTENTS Blower Data............................. Page 5 Dimensions.............................. Page 9 Dimensions Accessories................ Page 10 Electrical Data........................... Page 4 Electric Heat Data........................ Page 6 Features................................ Page 2 Installation Clearances.................... Page 5 Model Number Identification............... Page 1 Optional Accessories Selection Table....... Page 4 Specifications............................ Page 4 F E I B WARRANTY All covered components limited five years in residential applications, one year in non-residential applications. Refer to Lennox Limited Warranty Certificate included with each unit for additional details. APPLICATIONS 1.5 to 5 ton nominal sizes. Up-flow or horizontal applications. Optional down flow kit available for field conversion. CBX26UH models applicable to R 410A expansion valve systems in cooling applications and check and expansion valve systems in heat pump applications. CB26UH models applicable to R 22 expansion valve systems in cooling applications and check and expansion valve systems in heat pump applications. Wide range check and expansion valve is factory installed. See bulletins in section Air Conditioners for cooling capacities. See bulletins in section Heat Pump Outdoor Units for cooling and heating capacities. Optional field installed electric heaters available in several sizes for additive heating capacity. APPROVALS Tested with matching air conditioners and heat pump units in the Lennox Research Laboratory environmental test room in accordance with ARI Standard 210/240. Optional electric heaters are rated in accordance with US Department of Energy (DOE) test procedures and Federal Trade Commission (FTC) labeling regulations. Air handlers are UL Listed to US and Canadian safety standards and components within are bonded for grounding to meet safety standards for servicing required by CEC and NEC. ISO 9001 Registered Manufacturing Quality System. REFRIGERANT SYSTEM Refrigerant Line Connections Suction (vapor) and liquid lines have sweat connections that extended outside of the cabinet for ease of connection. See dimension drawing for locations. C D G B C H D Check and Expansion Valve Furnished CBX26UH models have non chlorine, ozone friendly, R 410A valve. CB26UH models have R 22 valve. Wide range valve. Chatleff style fitting. Factory installed on all models internal to cabinet. Copper Tube/Enhanced Fin Evaporator Coil Assembled in A" configuration. Provides extra large surface and contact area, excellent heat transfer and low air resistance for maximum efficiency. Precise circuiting for uniform refrigerant distribution. Precisely spaced ripple-edged aluminum fins fitted to durable seamless copper tubes. Fins are strengthened to resist bending and are equipped with collars that grip tubing for maximum contact area. Lanced fins provide maximum exposure of fin surface to air stream. Long life copper tubing is easy to service. Rifled tubing provides superior heat transfer. Flared shoulder tubing joints and silver soldering provide tight, leakproof joints. Coil thoroughly factory tested under high pressure to insure leakproof construction. FILTER (NOT FURNISHED) Filter is not furnished and must be field supplied. Filter rack furnished in cabinet for easy filter installation. See Specifications tables for filter sizes. CB26UH/CBX26UH 1.5 to 5 ton Air Handlers / Page 2

E F G H FEATURES BLOWER Resiliently mounted two-speed motor. Choice of blower speeds. See blower performance tables. Speed changes easily accomplished by a simple wiring change. Blower is easily removed from unit for servicing. Time Delay Blower Relay Relay allows 30 second blower on" delay before continuous fan or cooling operation and 30 second blower off" delay after continuous fan or cooling operation. CONTROLS Transformer and Blower Cooling Relay 24 volt transformer and blower cooling relay furnished as standard. Factory installed in the unit control box. OPTIONS Thermostat See Thermostat bulletins in Controls section and Lennox Price Book for a complete list of thermostats. CABINET Constructed of heavy gauge galvanized steel. Powder paint finish. Completely insulated with foil faced fiberglass insulation. Removable panels provide complete service access. Filter access door for easy filter replacement. Electrical inlets provided in sides and top of cabinet. See dimension drawing for locations. Knock outs in cabinet for drain connections for up flow (left and right) and horizontal applications. See dimension drawing. Up Flow/Horizontal Capability (Optional Down Flow) Shipped for up-flow and horizontal left hand discharge. May be field converted to horizontal right hand air discharge by repositioning horizontal drain pan. Optional down flow kit available for field conversion. Anti Microbial Dual Position Drain Pans Anti Microbial additive resists growth of mold and mildew on drain pan which improves indoor air quality and reduces drain line blockage. Drain pans designed for up-flow or horizontal applications. Deep, corrosion resistant high temperature engineered polymer drain pans have dual pipe drains. See dimension drawing. OPTIONS Down-Flow Combustible Floor Base (Down-Flow Only) Additive base required for models with electric heat installed in down-flow position on combustible floors. Down Flow Conversion Kit Required for field conversion to down flow position. Kit consists of drip shields and 2 brackets for repositioning coil and drain pan. Duct Adaptor Kit Kit allows direct connection of the ductwork to the return air opening of the air handler, not required if an external filter is used or if unit is installed on a platform in up flow applications. See dimension drawing. Horizontal Support Frame Kit Provides support of unit in horizontal applications. Consists of (2) 1 x 1-1/2 x 32-5/8 in. and (2) 1 x 3 x 53-7/8 in. painted heavy gauge cold rolled steel support channels with assembly and suspending holes. Bolts and nuts furnished for field assembly. Suspending rods must be field provided. I Side Return Unit Stand (Up-Flow Only) Raises unit 16 in. above floor for side return air duct connection. Eliminates need for wooden platform construction. All aluminum construction. Two adjustable frames fit all sizes. See Dimension Drawing. Wall Hanging Bracket Kit (Up-Flow Only) Allows unit to be hung on wall at any height. Consists of heavy gauge steel support brackets (one for air handler unit, one for wall mount). Screws furnished for fastening one bracket to unit. Bolts for fastening one bracket to wall are field provided. ELECTRICAL OPTIONS Electric Heat Field install internal to unit cabinet. Available in several kw sizes. See Electric Heat tables. Helix wound nichrome heating elements exposed directly in air stream resulting in instant heat transfer, low element temperatures and long service life. Each element equipped with accurately located limit control with fixed temperature off setting and automatic reset. Thermal sequencer relay brings elements on and off line, in sequence and equal increments, with time delay between each. Initiates and terminates blower operation. Heating control relay(s) furnished as standard. Factory assembled with controls installed and wired. Electric heat control wiring plugs into mating connector on air handler unit. Circuit Breaker Models ECB26 5CB, ECB26 7CB, ECB26 10CB, ECB26 15CB, ECB26 20CB heaters are equipped with circuit breakers for overload and short circuit protection. Factory wired and mounted on electric heat unit. Current sensitive and temperature actuated. Manual reset. Circuit breakers qualify as disconnect means at unit in many areas, eliminate the need for field provided disconnect. Consult local electrical code in your area. Circuit Breaker Cover Kit Flexible plastic cover protects circuit breaker. Recommended in areas with high humidity to prevent nuisance tripping. Single-point Power Source Control Box Control Box may be used with optional electric heat when single power supply is connected to multi circuit electric heat. Field installs external to the unit cabinet on either side or top. Constructed of heavy gauge steel, baked enamel finish, prepunched mounting holes, electrical inlet knockouts, and terminal strip. Removeable cover provides easy access. Dimensions (H x W x D) 7 x 7 x 4 in. CB26UH/CBX26UH 1.5 to 5 ton Air Handlers / Page 3

SPECIFICATIONS General Model Number (R 22) CB26UH 018 CB26UH 024 CB26UH 030 CB26UH 036 Data Model Number (R 410A) CBX26UH 018 CBX26UH 024 CBX26UH 030 CBX26UH 036 Nominal tonnage 1.5 2 2.5 3 Connections Suction/Vapor line (o.d.) in. (mm) sweat 3/4 (19) 3/4 (19) 7/8 (22.2) 7/8 (22.2) Liquid line (o.d.) in. (mm) sweat 3/8 (9.5) 3/8 (9.5) 3/8 (9.5) 3/8 (9.5) Condensate in. (mm) fpt (2) 3/4 (19) (2) 3/4 (19) (2) 3/4 (19) (2) 3/4 (19) Indoor Net face area ft. 2 (m 2 ) 4 (0.37) 4 (0.37) 4.88 (0.45) 4.88 (0.45) Coil Tube outside diameter in. (mm) 3/8 (9.5) 3/8 (9.5) 3/8 (9.5) 3/8 (9.5) Number of rows 3 3 3 3 Fins per inch (fins per m) 15 (591) 14 (551) 14 (551) 14 (551) Blower Wheel nominal diameter x width in. (mm) 10 x 6 (254 x 152) 1 Filters Size of filter in. (mm) 16 x 20 x 1 (406 x 508 x 25) 10 x 6 (254 x 152) 11 x 8 (279 x 203) 11 x 8 (279 x 203) Blower motor output hp (W) 1/4 (187) 1/4 (187) 1/4 (187) 1/3 (249) 16 x 20 x 1 18 x 20 x 1 (406 x 508 x 25) (457 x 508 x 25) 18 x 20 x 1 (457 x 508 x 25) ELECTRICAL DATA Voltage 1 phase (60 hz) 208/240V 208/240V 208/240V 208/240V 2 Maximum overcurrent protection (unit only) 15 15 15 15 3 Minimum circuit ampacity (unit only) 1.5 1.5 1.6 1.8 Shipping Data 1 package lbs. (kg) 129 (58) 131 (59) 148 (67) 148 (67) SPECIFICATIONS General Model Number (R 22) CB26UH 042 CB26UH 048 CB26UH 060 Data Model Number (R 410A) CBX26UH 042 CBX26UH 048 CBX26UH 060 Nominal tonnage 3.5 4 5 Connections Suction/Vapor line (o.d.) in. (mm) sweat 7/8 (22.2) 7/8 (22.2) 7/8 (22.2) Liquid line (o.d.) in. (mm) sweat 3/8 (9.5) 3/8 (9.5) 3/8 (9.5) Condensate in. (mm) fpt (2) 3/4 (19) (2) 3/4 (19) (2) 3/4 (19) Indoor Net face area ft. 2 (m 2 ) 5.84 (0.54) 7.58 (0.70) 8.76 (0.81) Coil Tube outside diameter in. (mm) 3/8 (9.5) 3/8 (9.5) 3/8 (9.5) Number of rows 3 3 3 Fins per inch (fins per m) 14 (551) 14 (551) 14 (551) Blower Wheel nominal diameter x width in. (mm) 11 x 8 (279 x 203) CB26UH/CBX26UH 1.5 to 5 ton Air Handlers / Page 4 11 x 8 (279 x 203) 11 1/2 x 9 (292 x 229) Blower motor output hp (W) 1/3 (249) 1/2 (373) 1/2 (373) 1 Filters Size of filter in. (mm) 18 x 25 x 1 18 x 25 x 1 18 x 25 x 1 (457 x 635 x 25) (457 x 635 x 25) (457 x 635 x 25) ELECTRICAL DATA Voltage 1 phase (60 hz) 208/240V 208/240V 208/240V 2 Maximum overcurrent protection (unit only) 15 15 15 3 Minimum circuit ampacity (unit only) 1.9 2.6 4.1 Shipping Data 1 package lbs. (kg) 172 (78) 177 (80) 190 (86) 1 Filter is not furnished and must be field supplied. 2 HACR type circuit breaker or fuse. 3 Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. Use wires suitable for at least 167 F (75 C). OPTIONAL ACCESSORIES MUST BE ORDERED EXTRA Model Circuit Breaker Cover Kit 93M85 93M85 93M85 93M85 Down Flow Combustible Floor Base 12W95 12W96 12W97 12W97 Down Flow Conversion Kit 12W61 12W61 12W61 12W61 Duct Adaptor Kit X8103 X8104 X8104 X8104 Horizontal Support Frame Kit 56J18 56J18 56J18 56J18 Side Return Unit Stand (Up Flow Only) 45K32 45K32 45K32 45K32 Single Point Power Source Control Box (for Electric Heat) 21H39 21H39 21H39 21H39 Wall Hanging Bracket Kit (Up Flow Only) 45K30 45K30 45K30 45K30 018 024 030 036 042 048 060

BLOWER DATA CB(X)26UH 018 BLOWER PERFORMANCE.10 25 1020 460 755 340.20 50 960 435 715 325.30 75 885 400 675 305.40 100 800 365 625 285.50 125 690 315 570 260.60 150 525 250 500 235 CB(X)26UH 030 BLOWER PERFORMANCE.10 25 1350 610 1145 520.20 50 1290 585 1090 495.30 75 1225 555 1030 465.40 100 1150 520 960 435.50 125 1065 485 875 395.60 125 965 455 775 365 CB(X)26UH 042 BLOWER PERFORMANCE.10 25 1940 880 1785 810.20 50 1845 835 1705 775.30 75 1745 790 1615 730.40 100 1630 740 1515 685.50 125 1495 680 1400 635.60 150 1330 630 1265 595 CB(X)26UH 024 BLOWER PERFORMANCE.10 25 1040 470 1000 455.20 50 980 445 940 425.30 75 905 410 870 395.40 100 815 370 785 355.50 125 705 320 680 310.60 150 535 250 530 250 CB(X)26UH 036 BLOWER PERFORMANCE.10 25 1560 705 1405 635.20 50 1480 670 1340 610.30 75 1390 630 1270 575.40 100 1290 585 1185 540.50 125 1170 530 1090 495.60 150 1015 480 975 460 CB(X)26UH 048 BLOWER PERFORMANCE.10 25 1945 880 1870 850.20 50 1860 845 1790 810.30 75 1765 800 1700 770.40 100 1660 155 1600 725.50 125 1540 700 1485 675.60 150 1395 660 1350 635 CB(X)26UH 060 BLOWER PERFORMANCE.10 25 2160 980 2075 940.20 50 2065 935 1985 900.30 75 1960 890 1885 855.40 100 1845 835 1775 805.50 125 1710 775 1645 745.60 150 1550 730 1495 705 INSTALLATION CLEARANCES Cabinet Plenum and Outlet duct on air handler units Plenum and Warm air duct within 3 feet (914mm) of cabinet Floor 0 inch (0 mm) 1 inch (25 mm) 1 inch (25 mm) Combustible CB26UH/CBX26UH 1.5 to 5 ton Air Handlers / Page 5

ELECTRIC HEAT DATA SINGLE PHASE ELECTRIC HEAT Description Input CB(X)26UH 018 / CB(X)26UH 024 Blower Motor Full Load 2 Minimum Circuit Ampacity 3 Maximum Overcurrent Protection Volt kw 1 Btuh Amps Circuit 1 Circuit 2 Circuit 1 Circuit 2 5 kw ECB26 5 (99M64) Terminal Block 208 3.8 12,800 1.5 19.5 30 ECB26 5CB (99M65) Circuit Breaker 220 4.2 14,300 1.4 22.2 30 230 4.6 15,700 1.4 22.2 30 240 5.0 17,100 1.4 22.2 30 7.5 kw ECB26 7 (99M67) Terminal Block 208 5.6 19,200 1.5 28.6 45 ECB26 7CB (99M66) Circuit Breaker 220 6.3 21500 1.4 32.7 45 230 6.9 23500 1.4 32.7 45 240 7.5 25,600 1.4 32.7 45 10 kw ECB26 10 (99M68) Terminal Block 208 7.5 25,600 1.5 37.6 60 ECB26 10CB (99M69) Circuit Breaker 220 8.4 28,700 1.4 43.1 60 SINGLE PHASE ELECTRIC HEAT Model Number 230 9.2 31,400 1.4 43.1 60 240 10.0 34,100 1.4 43.1 60 CB(X)26UH 030 Input Blower Motor Full Load 2 Minimum Circuit Ampacity 3 Maximum Overcurrent Protection Volt kw 1 Btuh Amps Circuit 1 Circuit 2 Circuit 1 Circuit 2 5 kw ECB26 5 (99M64) Terminal Block 208 3.8 12,800 1.6 19.6 30 ECB26 5CB (99M65) Circuit Breaker 220 4.2 14,300 1.5 22.3 30 230 4.6 15,700 1.5 22.3 30 240 5.0 17,100 1.5 22.3 30 7.5 kw ECB26 7 (99M67) Terminal Block 208 5.6 19,200 1.6 28.7 45 ECB26 7CB (99M66) Circuit Breaker 220 6.3 21500 1.5 32.8 45 230 6.9 23500 1.5 32.8 45 240 7.5 25,600 1.5 32.8 45 10 kw ECB26 10 (99M68) Terminal Block 208 7.5 25,600 1.6 37.7 60 ECB26 10CB (99M69) Circuit Breaker 220 8.4 28,700 1.5 43.2 60 230 9.2 31,400 1.5 43.2 60 240 10.0 34,100 1.5 43.2 60 15 kw ECB26 15CB (99M70) Circuit Breaker 208 11.3 38,400 1.6 37.7 18.1 60 30 220 12.6 43,000 1.5 43.2 20.8 60 30 230 13.5 47,000 1.5 43.2 20.8 60 30 240 15.0 51,200 1.5 43.2 20.8 60 30 NOTE Circuit 1 Minimum Circuit Ampacity includes the Blower Motor Full Load Amps. 1 Electric heater capacity only does not include additional blower motor heat capacity. 2 Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. Use wires suitable for at least 167 F (75 C). 3 HACR type breaker or fuse. CB26UH/CBX26UH 1.5 to 5 ton Air Handlers / Page 6

CB26UH ELECTRIC HEAT DATA SINGLE PHASE ELECTRIC HEAT Description Input CB(X)26UH 036 Blower Motor Full Load 2 Minimum Circuit Ampacity 3 Maximum Overcurrent Protection Volt kw 1 Btuh Amps Circuit 1 Circuit 2 Circuit 1 Circuit 2 5 kw ECB26 5 (99M64) Terminal Block 208 3.8 12,800 1.8 19.8 30 ECB26 5CB (99M65) Circuit Breaker 220 4.2 14,300 1.7 22.5 30 230 4.6 15,700 1.7 22.5 30 240 5.0 17,100 1.7 22.5 30 7.5 kw ECB26 7 (99M67) Terminal Block 208 5.6 19,200 1.8 28.9 45 ECB26 7CB (99M66) Circuit Breaker 220 6.3 21500 1.7 33.0 45 230 6.9 23500 1.7 33.0 45 240 7.5 25,600 1.7 33.0 45 10 kw ECB26 10 (99M68) Terminal Block 208 7.5 25,600 1.8 37.9 60 ECB26 10CB (99M69) Circuit Breaker 220 8.4 28,700 1.7 43.4 60 230 9.2 31,400 1.7 43.4 60 240 10.0 34,100 1.7 43.4 60 15 kw ECB26 15CB (99M70) Circuit Breaker 208 11.3 38,400 1.8 37.9 18.1 60 30 SINGLE PHASE ELECTRIC HEAT Model Number 220 12.6 43,000 1.7 43.4 20.8 60 30 230 13.5 47,000 1.7 43.4 20.8 60 30 240 15.0 51,200 1.7 43.4 20.8 60 30 CB(X)26UH 042 Input Blower Motor Full Load 2 Minimum Circuit Ampacity 3 Maximum Overcurrent Protection Volt kw 1 Btuh Amps Circuit 1 Circuit 2 Circuit 1 Circuit 2 5 kw ECB26 5 (99M64) Terminal Block 208 3.8 12,800 1.9 20.0 30 ECB26 5CB (99M65) Circuit Breaker 220 4.2 14,300 1.8 22.6 30 230 4.6 15,700 1.8 22.6 30 240 5.0 17,100 1.8 22.6 30 7.5 kw ECB26 7 (99M67) Terminal Block 208 5.6 19,200 1.9 29.0 45 ECB26 7CB (99M66) Circuit Breaker 220 6.3 21500 1.8 33.1 45 230 6.9 23500 1.8 33.1 45 240 7.5 25,600 1.8 33.1 45 10 kw ECB26 10 (99M68) Terminal Block 208 7.5 25,600 1.9 38.0 60 ECB26 10CB (99M69) Circuit Breaker 220 8.4 28,700 1.8 43.5 60 230 9.2 31,400 1.8 43.5 60 240 10.0 34,100 1.8 43.5 60 15 kw ECB26 15CB (99M70) Circuit Breaker 208 11.3 38,400 1.9 38.0 18.1 60 30 220 12.6 43,000 1.8 43.5 20.8 60 30 230 13.5 47,000 1.8 43.5 20.8 60 30 240 15.0 51,200 1.8 43.5 20.8 60 30 NOTE Circuit 1 Minimum Circuit Ampacity includes the Blower Motor Full Load Amps. 1 Electric heater capacity only does not include additional blower motor heat capacity. 2 Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. Use wires suitable for at least 167 F (75 C). 3 HACR type breaker or fuse. CB26UH/CBX26UH 1.5 to 5 ton Air Handlers / Page 7

CB26UH ELECTRIC HEAT DATA SINGLE PHASE ELECTRIC HEAT Description Input CB(X)26UH 048 Blower Motor Full Load 2 Minimum Circuit Ampacity 3 Maximum Overcurrent Protection Volt kw 1 Btuh Amps Circuit 1 Circuit 2 Circuit 1 Circuit 2 5 kw ECB26 5 (99M64) Terminal Block 208 3.8 12,800 2.6 20.7 30 ECB26 5CB (99M65) Circuit Breaker 220 4.2 14,300 2.5 23.3 30 230 4.6 15,700 2.5 23.3 30 240 5.0 17,100 2.5 23.3 30 7.5 kw ECB26 7 (99M67) Terminal Block 208 5.6 19,200 2.6 29.7 45 ECB26 7CB (99M66) Circuit Breaker 220 6.3 21500 2.5 33.8 45 230 6.9 23500 2.5 33.8 45 240 7.5 25,600 2.5 33.8 45 10 kw ECB26 10 (99M68) Terminal Block 208 7.5 25,600 2.6 38.7 60 ECB26 10CB (99M69) Circuit Breaker 220 8.4 28,700 2.5 44.2 60 230 9.2 31,400 2.5 44.2 60 240 10.0 34,100 2.5 44.2 60 15 kw ECB26 15CB (99M70) Circuit Breaker 208 11.3 38,400 2.6 38.7 18.1 60 30 220 12.6 43,000 2.5 44.2 20.8 60 30 230 13.5 47,000 2.5 44.2 20.8 60 30 240 15.0 51,200 2.5 44.2 20.8 60 30 20 kw ECB26 20CB (99M71) Circuit Breaker 208 15.0 51,200 2.6 38.7 36.1 60 60 SINGLE PHASE ELECTRIC HEAT Model Number 220 16.8 57,300 2.5 44.2 41.7 60 60 230 18.4 62,700 2.5 44.2 41.7 60 60 240 20.0 68,200 2.5 44.2 41.7 60 60 CB(X)26UH 060 Input Blower Motor Full Load Amps 2 Minimum Circuit Ampacity 3 Maximum Overcurrent Protection Volt kw 1 Btuh (240V) Circuit 1 Circuit 2 Circuit 1 Circuit 2 5 kw ECB26 5 (99M64) Terminal Block 208 3.8 12,800 4.1 22.2 30 ECB26 5CB (99M65) Circuit Breaker 220 4.2 14,300 3.9 24.7 30 230 4.6 15,700 3.9 24.7 30 240 5.0 17,100 3.9 24.7 30 7.5 kw ECB26 7 (99M67) Terminal Block 208 5.6 19,200 4.1 31.2 45 ECB26 7CB (99M66) Circuit Breaker 220 6.3 21500 3.9 35.2 45 230 6.9 23500 3.9 35.2 45 240 7.5 25,600 3.9 35.2 45 10 kw ECB26 10 (99M68) Terminal Block 208 7.5 25,600 4.1 40.2 60 ECB26 10CB (99M69) Circuit Breaker 220 8.4 28,700 3.9 45.6 60 230 9.2 31,400 3.9 45.6 60 240 10.0 34,100 3.9 45.6 60 15 kw ECB26 15CB (99M70) Circuit Breaker 208 11.3 38,400 4.1 40.2 18.1 60 30 220 12.6 43,000 3.9 45.6 20.8 60 30 230 13.5 47,000 3.9 45.6 20.8 60 30 240 15.0 51,200 3.9 45.6 20.8 60 30 20 kw ECB26 20CB (99M71) Circuit Breaker 208 15.0 51,200 4.1 40.2 36.1 60 60 220 16.8 57,300 3.9 45.6 41.7 60 60 230 18.4 62,700 3.9 45.6 41.7 60 60 240 20.0 68,200 3.9 45.6 41.7 60 60 NOTE Circuit 1 Minimum Circuit Ampacity includes the Blower Motor Full Load Amps. 1 Electric heater capacity only does not include additional blower motor heat capacity. 2 Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. Use wires suitable for at least 167 F (75 C). 3 HACR type breaker or fuse. CB26UH/CBX26UH 1.5 to 5 ton Air Handlers / Page 8

DIMENSIONS INCHES (MM) UP FLOW POSITION SHOWN B 1 (25) LINE VOLTAGE Right, Left and Top C LOW VOLTAGE Right Side Only AIR FLOW SUCTION LINE A CONDENSATE DRAIN PIPING PLATE (4) (2 1/4 x 3 3/4) FILTER ACCESS E D F LIQUID LINE OPTIONAL DUCT ADAPTOR KIT (Kit allows direct connection of the ductwork to the return air opening of the air handler, not required if an external filter is used or if unit is installed on a platform in up flow applications.) 3/4 (19) G H 2-1/2 (Opening) 2-1/2 1-1/2 (Opening) 1-1/2 (64) (64) (38) (38) FRONT VIEW SIDE VIEW Dimension 018, 024 030, 036 042, 048 060 inches mm inches mm inches mm inches mm A 46 3/4 1187 51 1295 54 1372 60 1524 B 18 1/2 470 21 1/4 540 21-1/4 540 21-1/4 540 C 22 559 22 559 26 660 26 660 D 11 279 12 1/2 318 12 305 11 3/4 298 E 16 406 18 1/2 470 16 3/4 425 17 432 F 5 1/2 140 6 152 4 102 4 102 G 13 1/2 343 16 406 16 406 16 406 H 19 483 19 483 23 584 23 584 Supply Air Depth 17 432 17 432 21 533 21 533 Opening Width 16 1/2 419 19 1/4 489 19 1/4 489 19 1/4 489 CB26UH/CBX26UH 1.5 to 5 ton Air Handlers / Page 9

ACCESSORY DIMENSIONS INCHES (MM) DOWN-FLOW COMBUSTIBLE FLOOR BASE 1-1/2 (38) AIR HANDLER 1-1/2 (38) D SIDE RETURN UNIT STAND (Up Flow Only) B SUPPLY AIR OPENING A Opening 16 (406) 1-1/2 (38) 6 (152) TOP VIEW 1/4 (6) D Opening C 21-1/4 (540) ADJUSTABLE 20 (508) to 25 (635) ALL UNITS DOWN-FLOW COMBUSTIBLE FLOOR BASE SIDE VIEW 1 1/2 (38) Usage 018 024 (12W95) 030 036 (12W96) 042 048 060 (12W97) in. mm in. mm in. mm A (floor) 19 483 21 3/4 552 21 3/4 552 B 16 7/8 429 19 5/8 498 19 5/8 498 C 23 1/8 587 23 1/8 587 27 7/8 708 D (floor) 19 1/2 495 19 1/2 495 26 3/4 679 CB26UH/CBX26UH 1.5 to 5 ton Air Handlers / Page 10

Visit us at www.lennox.com For the latest technical information, www.lennoxdavenet.com Contact us at 1 800 4 LENNOX NOTE Due to Lennox ongoing committment to quality, Specifications, Ratings and Dimensions subject to change without notice and without incurring liability. Improper installation, adjustment, alteration, service or maintenance can cause property damage or personal injury. Installation and service must be performed by a qualified installer and servicing agency. 2005 Lennox Industries Inc.