1SC-SSC Splice Connection Kit Installation Instructions

Similar documents
JB-RTD-STAND RTD PIPE STAND FOR COMBINATION POWER CONNECTION BOX AND ELECTRONIC CONTROLLER INSTALLATION INSTRUCTIONS

HWT-P HWAT POWER CONNECTION KIT WITH END SEAL INSTALLATION INSTRUCTIONS

FTC-HST WARNING: CAUTION:

JBS-100-ECP-A COMBINATION POWER CONNECTION BOX AND DIGITAL ELECTRONIC CONTROLLER INSTALLATION INSTRUCTIONS

JBS-100-EC Electronic controller replacement kit for JBS-100-ECP-A and JBS-100-ECW-A Installation Instructions

JBM-100-LBTV2 Power Connection, Powered Splice, Dual Power Connection, or Splice with Junction Box

C A Heating Cable Gland Kit

TT3000 and TT5000 Series

FreezGard. Self-regulating crankcase heater. Product Overview

HOT WATER TEMPERATURE MAINTENANCE HWAT SYSTEM

Longline Heating. Contents. Introduction

Consignes d installation

HEATING CABLE RATINGS APPROVALS* Drexan Energy Systems, Inc. Kelowna, BC, Canada, V4V 1S5

H908 WinterGard Plug-in Power Connection Kit with End Seal

HS-TSPLICE - HEATSHRINK TEE / SPLICE. Installation Instructions

Design Guide Design Notes Design Examples Technical Data Sheets Expanded Capabilities Specifications Warranty

RayClic Connection System

CSI Master Format 2004 Guide Specification for: Flow Maintenance of Aboveground Fuel Oil Lines

CSI Master Format 2004 Guide Specification for: Flow Maintenance of Above Ground Greasy Waste Disposal Lines

Frost Heave Protection System Installation and Operation Manual

NELSON HEAT TRACING SYSTEMS ALT-BC STANDARD POWER CONNECTION KIT

C Electrical Connection Kit

Data Sheet. Self regulating heating tapes. RS stock numbers

CSI Master Format 2012 Guide Specification for: Hot Water Temperature Maintenance (HWAT) Systems

Raychem Heating System

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

NELSON HEAT TRACING SYSTEMS

Data Sheet. Self regulating process heating tapes RS stock numbers ,

NELSON HEAT TRACING SYSTEMS

NELSON HEAT TRACING SYSTEMS

NELSON HEAT TRACING SYSTEMS INSTALLATION

TOUCH 1500 User Interface Terminal for Raychem NGC Systems Installation Instructions

FIRE SPRINKLER SYSTEM FREEZE PROTECTION XL-TRACE SYSTEM

Installation Procedure for D-200 series Shielded Cable Splice Kits with MiniSeal Crimp Primary Splices

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

COMMERCIAL & RESIDENTIAL SELF-REGULATING HEATING PRODUCTS APPLICATION AND DESIGN GUIDE EUROPE, MIDDLE EAST, AFRICA

NGC-UIT-ORD User interface terminal for Raychem NGC systems Installation Instructions

SERGE BARIL HEAT TRACING SYSTEMS

Installation Instructions

KE-Series Constant-Wattage Heating Cable

NELSON HEAT TRACING SYSTEMS

NGC-UIT2-ORD-R Remote User Interface Terminal for Raychem NGC Systems Installation Instructions

THERMAL BUILDING SOLUTIONS EN-TraceTekTTSIM1A-IM-H /16

Manual No: Revision: D. Sump Sensor. Installation Guide

sulfur transport pipelines Safe, Reliable and Cost-Effective Heat Management System

NELSON HEAT TRACING SYSTEMS

NELSON HEAT TRACING SYSTEMS

TTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS

Pipe Freeze Protection. Flow Maintenance. Introduction. XL-Trace System

NELSON HEAT TRACING SYSTEMS

NELSON HEAT TRACING SYSTEMS

XL-Trace System Application and Design Guide

CSI Master Format 2004 Guide Specification for: Snow Melting (Mineral Insulated)

TraceTek Sensing Cable for Aboveground Leak Detection Installation Instructions

CSI Master Format 2004 Guide Specification for: Freezer Frost Heave Prevention (Mineral Insulated)

Sensor Interface Module Installation/Operation Instructions

DESCRIPTION. 42 mm. 125 mm

ESD Safe UL Approved INSTRUCTIONAL MANUAL EX V EX V TEMPERATURE CONTROLLED SOLDERING STATION

THERMAL MANAGEMENT SOLUTIONS

SEALING FIBER SEALING COMPOUND

HHS-WWH HOPPER HEATING SYSTEM WRAP-WOUND HEATER INSTALLATION INSTRUCTIONS DESCRIPTION. HHS-WWH PRODUCT SPECIfICATIONS

TECK-40 Series 1000V Class Splice for 4/C Armored Teck Power Cables

DISHWASHER. Models DW2432 and DW2432SS. Installation Manual. Write Serial Number (on inner door of unit) here:

INSTALLATION INSTRUCTIONS

Model BX-903, BX-904 and BX-906 Environmental Enclosure For BAM-1020 Operation Manual

I<enmore Elite. instructions dlnstallation. Installation Guide Instrucciones de Instalaci6n. English / Espafiol/Frangais

52 CEILING FAN READ AND SAVE THESE INSTRUCTIONS FAN RATING AC 120V.

Heat Exchanger Block Replacement Instructions

DESTU. Direct Entry Sealed Termination Unit. Installation Instructions. Suitable for use in either safe or hazardous areas.

Manual No: Revision: E. Groundwater Sensor. Installation Guide

Installation Instructions

Top Control Dishwasher

SMF PUMP OWNER S MANUAL

Installation GUIDE VDWU524SS VDWU524WSSS FDWU524WS FDWU524 VDWU324SS FDWU324

C-IV 60 CEILING FAN READ AND SAVE THESE INSTRUCTIONS. FAN RATING AC 120V. 60Hz

XAGA 550/550-L. Aerial Splice Closure. 1. General Description. 2. Warnings. 3. Cautions

TT3000 and TT5000 Series

Air Conditioner. user installation & manual manual. imagine the possibilities

Gardian W51. Approvals

Manual No: Revision: D. Mag Sump Sensor. Installation Guide

TraceTek Sensing Cable for Underground Leak Detection Installation Instructions. Description. Heat shrink tubing segments. Optional Materials

Fillmore Small Pendant Assembly and Installation Instructions

Dishwasher Installation Manual

INSTALLATION AND COMMISSIONING MANUAL. Neos 100S Integra 20X, 30S, 35X, 40X, 50X

A PROUD HERITAGE OF EXPERIENCE & QUALITY DISHWASHER BR- DWSH01- S

Installation and Operation Instructions. Versa. Screw Plug Oil & Water Immersion Heater. PD January 2018

PME. Series Enclosures. Battery Enclosure (BE) Field Upgrade Installation Instructions. Effective: January, Alpha Technologies

ECONO FLO 2.7HP VARIABLE SPEED PUMP OWNER S MANUAL

Installation Instructions

Installation Guide. For Models: E-MLV36BNK4LK1 E-MLV36ESP4LK1 E-MLV36WW4LK1 READ THESE INSTRUCTIONS AND AND SAVE THEM FOR FUTURE USE

INSTALLATION INSTRUCTIONS FOR 6532 SERIES PACKAGE HEAT PUMP

XL-Trace System. Installation and Operation manual for pipe freeze protection and flow maintenance

BETACURE 100 CO-REACTANT

THERMAL MANAGEMENT SOLUTIONS

LaceyTM. Instruction Manual. Includes our new CoolTouch TM 6 Speed DC Control System Looks permanent, but goes wherever you go! U.S.

INSTALLATION INSTRUCTIONS

ENRGY CURB APPLICATION GUIDE FOR TPO ROOFING SYSTEMS

Parts & Material Included

INSTALLATION INSTRUCTIONS UNDERCOUNTER DISHWASHERS

V Refrigeration Module

Transcription:

1SC-SSC Splice Connection Kit Installation Instructions Description The 1SC-SSC is a NEMA 4 rated splice connection kit for use with Raychem 1SC30, 40, 50, 60, 70, 80 (-CT) and 1SC/H30, 40, 50, 60, 70, 80 (-CT) series heating cables in hazardous locations with low mechanical abuse. This kit may be installed at temperatures as low as 40 F ( 40 C). For easier installation, store above freezing until just before installation. For technical support, call Pentair Thermal Management at (800) 545-6258. Approvals Hazardous Locations (1) (2) Ex e II T -W -W (1) for T-Rating, see design documentation (2) for 1SC60, 70, 80(-CT) and 1SC/H60, 70, 80(-CT) only. Nonhazardous Locations Tools Required Utility knife Diagonal cutters Wire strippers Slotted screwdriver Adjustable wrench Disposable towel or rag Solder gun or torch (with small tip) Thomas & Betts WT2000 crimp tool or equivalent(pn 273435-000) Thomas & Betts TBM5S crimp tool or equivalent (PN P000000585), see Step 8 Crimp tools can be ordered from Pentair Thermal Management. Additional Materials Required Glass cloth tape: GT-66 for installation temperature above 40 F (4 C) GS-54 for installation temperature above 40 F ( 40 C) WARNING: This component is an electrical device that must be installed correctly to ensure proper operation and to prevent shock or fire. Read these important warnings and carefully follow all of the installation instructions. To minimize the danger of fire from sustained electrical arcing if the heating cable is damaged or improperly installed, and to comply with the requirements of Pentair Thermal Management, agency certifications, and national electrical codes, groundfault equipment protection must be used. Arcing may not be stopped by conventional circuit breakers. Component approvals and performance are based on the use of Pentair Thermal Management-specified parts only. Do not use substitute parts or vinyl electrical tape. Damaged conductors can overheat or short. Do not break conductor wire strands when scoring the jacket or removing insulation. Keep components and heating cable ends dry before and during installation. Use only fire-resistant insulation materials, such as fiberglass wrap or flame-retardant foam. Soldering guns or torches can cause fire or explosion in hazardous areas. Be sure there are no flammable materials or vapors in the area before using these tools. Wrap exposed conductors with supplied tape strips to prevent shorts. CAUTION: Health Hazard: Hot solder can burn eyes and skin. Fumes during soldering are irritating to eyes and may cause headache and respiratory system irritation or damage. Prolonged or repeated exposure to rosin flux fumes during soldering may result in allergic reaction in a sensitive person, resulting in asthma symptoms. Refer to MSDS VEN0043 for more information. Silicone rubber compound, Part A and Part B, may generate flammable and explosive hydrogen gas if it comes in contact with an acidic, basic or oxidizing material. Personal contact with the silicone rubber compound may cause slight eye or skin irritation. Refer to MSDS VEN0030 and VEN0031 for more information. CHEMTREC 24-hour emergency telephone: (800) 424-9300 Non-emergency health and safety information: (800) 545-6258. 1 / 6

KIT contents Item qty Description A 1 Box with cover, gasket, and 2 screws B 2 Bushings C 4 Grommets D 8 Tape strips (5 required, 3 extra) E 1 Pipe banding kit F 1 ETL-SPLICE label G 2 Cable lubricants H 1 Bolt, lock washer and nut I 2 Thomas & Betts #C10-14 ring terminals J 1 Coil of Kester 48 core LF solder for nickel K 8 Thomas & Betts splices, spares included L 1 KE 1204 silicone rubber potting compound Part A M 1 KE 1204 silicone rubber potting compound Part B N 2 Stir sticks O 2 Material Safety Data Sheets (not shown) A B C D E F G H I J K L M N Heating cable construction 1 Heating cable types 1SC30, 40, 50, 60, 70 and 80 (-CT) 1SC/H30, 40, 50, 60, 70 and 80 (-CT) Outer jacket Tinned-copper braid Inner jacket Fiberglass braid Plated copper conductor 24 in (60 cm) Allow extra heating cable for a service loop. First heating cable Second heating cable WARNING: WARNING: Ensure the cable does not cross over itself to prevent damage to the jacket or shorting. 2 3 Heating cable (1) Grommet 1SC30, 40, 50 Small hole 1SC60, 70, 80 Large hole (1) The above table is also for 1SC/H30, 40, 50, 60, 70, 80 (-CT) heating cables. 2 in (50 mm) Select appropriate grommet (see table). For easier installation apply cable lubricant inside grommet from each end. Insert the heating cable into the bushing and grommet. Repeat for second heating cable. Position box on second heating cable as shown. 2 / 6

4 5 1-5/8 in (40 mm) Lightly score outer jacket around and down as shown. Bend heating cable to break jacket at score, then peel off jacket. Use a pointed object to separate the braid from the heating cable. Twist the braid to make a pigtail. 6 7 3/4 in (20 mm) Fiberglass braid Remove 3/4 inch (20 mm) inner jacket and glass fiber braid to expose the bare conductor. Do not cut conductor strands. Crimp ring terminal onto braid, using the Thomas & Betts WT2000 crimp tool. Repeat steps 4 through 7 for second heating cable. 8 Crimp heating cable conductors together using the appropriate splice and crimp tool (see table). Overlap conductors in splice. Crimp the splice twice when using the WT2000 crimp tool. WARNING: Using the wrong splice can cause overheating. Use only the splice specified for the cable type. Heating Thomas & Betts cable (1) catalog no. Description crimp tool crimp tool die 1SC30-CT B14-PS-M Small silver WT2000 Non-Insul 1SC40-CT B14-PS-M Small silver WT2000 Non-Insul 1SC50-CT C10-PS-D Large silver WT2000 Non-Insul 1SC60-CT C10-PS-D Large silver WT2000 Non-Insul 1SC70-CT 54610 Blue TBM5S Blue 1SC80-CT 54620 Brown TBM5S Brown (1) The above table is also for 1SC/H30, 40, 50, 60, 70, 80 (-CT) heating cables. For replacement splices, call Pentair Thermal Management at (800) 545-6258. 3 / 6

9 WARNING: Fire and Health Hazard Soldering tools or minitorches can cause fire or explosion in hazardous areas. Be sure there are no flammable materials or vapors in the area before using these tools. Follow all site safety guidelines when working in hazardous areas. Refer to solder material safety data sheet packaged with kit. Do not overheat or char the conductor insulation. Inhalation of fumes can cause polymer fume fever, flu-like symptoms, irritation, and difficult breathing. Use only solder provided with kit. Only Kester 48 core LF has been qualified with SC cables. Heat the splice using a soldering tool, or a propane or MAPP gas torch. Note: MAPP gas may be required if the connections are being soldered at temperatures below 4 F ( 20 C). Heat the center of the splice until it is hot enough to melt the solder placed at one end of the connection. The solder should flow between the inside of the splice and heating cable conductors. Repeat for the other end of the splice. Allow the connection to cool before proceeding to the next step. 10 IMpORTANT: To ensure proper electrical insulation, use the specified high temperature Teflon tape provided with the kit. Do not use common vinyl tape that does not have adequate temperature rating. Slowly remove release liner from tape strips while wrapping tape around the connection. Use three strips of tape, covering splice and 1/4-inch (6 mm) of inner jacket (approximately three overlapped layers). Wrap braid with tape strips. Release liner (remove and discard) 1/4 in (6 mm) min. 6 in (15 cm) Tape strips 11 12 IMPORTANT: Do not damage outer jacket of heating cable Center connection in the box. All braid wires must be fully contained within conduit box. Reposition connection if necessary. Apply cable lubricant to the outside surface of the grommet, cold lead, heating cable and end of bushing. Slide grommets into ends of box and seat to the bottom of the threaded section using a screwdriver or blunt instrument. Remove any slack in cable. Slide bushing into end of box. Screw into threaded section and tighten with wrench. Position lock washer and nut on outside of box. Fasten braid ring terminals using bolt. Push braid wires as far away from connection as possible. Position taped connection so it is centered and not touching sides of enclosure, braid wires or ground screw. 4 / 6

13 WARNING: Health Hazard Refer to silicone rubber material safety data sheet packaged with kit. Open the two containers: one labeled Part A, and the other Part B. Use separate wooden sticks to stir the contents of each container until smooth and homogeneous. Pour all the contents of the container labeled Part B into the container labeled Part A and mix thoroughly until the color is uniform. 14 15 Cover Gasket Pour the potting compound mixture into the box. Potting compound must fill the box and cover all connections. Secure the cover and gasket using the two screws provided. 16 WARNING: Fire and Shock Hazard To prevent cable damage, do not position pipe banding over the heating cable. Ensure the cable does not cross over itself to prevent damage to the jacket and shorting. Use pipe clamp banding and fasteners to secure splice box to pipe. Secure heating cable service loops to pipe using glass cloth tape. Install ETL-SPLICE label on insulation cladding. Leave these instructions with the end user for future reference. Glass cloth tape Pipe banding (under heating cable) 5 / 6

WWW.THERMAL.PENTAIR.COM NORTH AMERICA Tel: +1.800.545.6258 Fax: +1.800.527.5703 Tel: +1.650.216.1526 Fax: +1.650.474.7711 thermal.info@pentair.com Europe, Middle East, Africa Tel: +32.16.213.511 Fax: +32.16.213.603 thermal.info@pentair.com Asia Pacific Tel: +86.21.2412.1688 Fax: +86.21.5426.2917 cn.thermal.info@pentair.com Latin America Tel: +55.11.2588.1400 Fax: +55.11.2588.1410 thermal.info@pentair.com Pentair and SC are owned by Pentair or its global affiliates. All other trademarks are the property of their respective owners. Pentair reserves the right to change specifications without prior notice. 2004-2013 Pentair. PN P000000314 6 / 6