All alerts are still logged as alarms and also show up in the current alarm list.

Similar documents
Some alarms can be manually cleared from the current alarms list. This is indicated for the alarms where this is possible.

TECHNICAL, OPERATING & INSTALLATION MANUAL TC 15, 33, 52 AIR COOLED PACKAGED WATER CHILLERS

Digital Precise Air Control - DPAC

Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA

Heat Pump Defrost Board Replacement Kit

BasicTroubleshooting Information and Guidelines

Series 9. Commissioning Checklist. MISSION CRITICAL Air Conditioning Systems. ClimateWorx International Inc.

L SERIES UNITS 504,908M. 10/2004 Supersedes 9/2004

SEQUENCE OF OPERATION FOR ALC CONTROL AIR SOURCE HEATPUMP RECIRCULATION AIR WITH ECONOMIZER

I/O ZONE 560/583 USERS GUIDE

SEQUENCE OF OPERATION FOR ALC CONTROL AIR SOURCE HEATPUMP 100% OUTSIDE AIR

L SERIES UNITS 505,191M. 4/2006 Supersedes 504,908M

1025, BOUL. MARCEL-LAURIN INSTRUCTION MANUAL FOR WATER COOLED ENVIROCHILL CHILLER. Prepared par Claude Gadoury, P. Eng MTL TECHNOLOGIES INC.

π H-6621 INDUSTRIAL DEHUMIDIFIER WARNINGS SPECIFICATIONS uline.com WATER REMOVAL ELECTRICAL REQUIREMENTS BUILT-IN ELECTRICAL SAFETY

FAULT CODES. Included in this section are instructions to Reset the two Hot Tank Overload Devices (High Safety Limit).

OPERATION INSTRUCTIONS DEMAND DEFROST CONTROL BOARD MODEL FOR USE WITH MODELS: AFFINITY, ECHELON, ACCLIMATE HEAT PUMP SERIES

Installation Instructions / User s Manual TSTAT0406 and TSTAT0408

TECHNICAL MANUAL CVM 20 C 5005 CV/04-99 GB

I/O ZONE 560/583 AND OPERATION MANUAL

McQuay BACnet Solution: Microtech II Self-contained Unit Controller with Discharge Air Control (DAC)

SERVICE MANUAL FOR 6537 & 6538 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS

L SERIES UNITS 504,520M. 10/2001 Supersedes 504,413M

OPERATING MANUAL Enertronic Control System 2

MicroTech Series-200 Flooded Screw Chiller

Table of Contents. Service Procedures. Service Procedures. Measuring Superheat (4) Measuring Subcooling (5) Airflow Calculation (6-8)

The Book of AERMEC NRL Sequence of Operation

Container Refrigeration

York 25-Ton VAV Rooftop Unit

TROUBLESHOOTING GENERAL TROUBLESHOOTING PROBLEM PROBABLE CAUSE CORRECTIVE ACTION

MicroTech Series 200 Centrifugal Chiller

WaterFurnace FX10 Application Guide Reversible Chiller

M1 8 VERSION 6.0x INTEGRATED MODULAR CONTROLLER (IMC)

CommStat 6. Controller for Redundant HVAC Systems PRODUCT DATA SHEET

Your Home. Jacco & Assoc.

Air Conditioning Operation and Troubleshooting Matt Dunham

PS SERIES PARALLEL RACK SYSTEM START UP GUIDE

INSTRUCTION MANUAL INSTALLATION OPERATION MAINTENANCE

XWA11V. Walk-In Temp / Door /Alarm / Light Module

Service Manual. Chiller unit MQH R 410A. Release Date Rev Review Date november

MicroTech Rooftop/RMC

BACnet Points List for Single Compressor Water to Water PROSSWWE-01

Safety & Installation Instructions

OWNERS MANUAL YEAR LIMITED WARRANTY READ ALL INSTRUCTIONS BEFORE PROCEEDING. Store this booklet for future reference

Reference Guide for Microprocessor Controller

BACnet Points for Single Compressor Water-to- Air Heat Pumps With Hot Gas Reheat Utilizing the FX10 Controller

OWNERS MANUAL YEAR LIMITED WARRANTY READ ALL INSTRUCTIONS BEFORE PROCEEDING. Store this booklet for future reference

Bulletin (Jan 2011) And User s Guide

TAP v2.10 Version Date: 6/12/13. Document Microprocessor Controller for Tempered Air Products

Controls Lite. Controls Instruction, Operation, and Maintenance. IOM-C Part Number

SA Series Start up Report

1F Day 5/1/1 Day Non-Programmable. W/ Economizer Max. Stage Heat/Cool 1/1 1/2 2/2 2/3 3/1 3/2 4/2 4/3

USER MANUAL WARNING! CONTENTS MODEL SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING

Refrigerated air dryers

TOTAL SOLUTIONS. Liquid Level Control Product Guide. MATELEC AUSTRALIA innovative by design

TWLC - Tempered Water Logic Controller. The Intelligent Control

SEQUENCE OF OPERATIONS

Operating Instructions XWA11V XWA11V. Walk-In Temp / Door /Alarm / Light Module

OPERATING MANUAL Enertronic Control System 2

ADDISON SEQUENCE OF OPERATION FOR ALC CONTROL AIRSOURCE HEATPUMP 100% OUTDOOR AIR VERSION Telephone:

A. Base Bid: 1. Heating Contractor provide: a. Control sequences for HVAC systems, subsystems, and equipment.

Operating Instructions XWA11V. XWA11V-KIT Walk-In Temp / Door /Alarm / Light Module with Mounting Box and Wiring

ADDISON SEQUENCE OF OPERATION FOR ALC CONTROL AIRSOURCE COOLING-ONLY 100% OUTSIDE AIR VERSION Telephone:

Installation Instructions

REFRIGERANT ON-VEHICLE INSPECTION AC 14

Gas Safety Products. Installation, operating and maintenance 11/18/2015. Merlin 1000S+ Gas Utility & Electrical Isolation Controller

Tempered Water Logic Control OPERATION l TROUBLE SHOOTING

NC NC Series. NG Series. Seresco s NG Series Fluid Coolers & NC Series Outdoor Condensers Quiet, efficient reliable heat rejection

QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6535D, 6537C, 6538 A&B SERIES TWO TON PACKAGED HIGH EFFICIENCY HEAT PUMPS

SERVICE INSTRUCTIONS FUSION-TEC WALL-MOUNT AIR CONDITIONER

Sales and Engineering Data Sheet ED

WIRING DIAGRAMS R410A MODELS PAC 2OAC/2OACH CAC OWC PWC

PS SERIES PARALLEL RACK SYSTEM GLYCOL CHILLER START UP GUIDE 11/03/2015 Rev 00

OWNER S MANUAL. Vintage Classic HEAT COOL models. Proudly Made in the USA

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Heat Pump Water Heater (Generation 4) Troubleshooting (Effective 1 Nov 2016)

WARNING Important Safety Information

OWNERS MANUAL YEAR LIMITED WARRANTY READ ALL INSTRUCTIONS BEFORE PROCEEDING. Store this booklet for future reference

YCIV Hz & Hz

C-TRAC3 COMMUNICATION MANUAL FOR. BACnet NOVEMBER 2010 TO JANUARY 2014 USA HEAD OFFICE AND FACTORY

MicroTech Self-Contained Air Conditioning System

SPECIFICATIONS for AIR CONDITIONING CONTROLLER ZONE CONTROL

Dixell Installing and Operating Instructions release 7.0

WARNING Important Safety Information

Service Manual. Commercial Series Refrigerated Kitchen Equipment Models Undercounter Worktop Prep Table. hoshizakiamerica.com

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

Unit Controller (UC8) Quick Reference Operation and Fault Diagnosis

CommStat 4. Controller for Redundant Telecom HVAC Systems PRODUCT DATA SHEET. Features and Benefits

Open Protocol Data Communications

*IG1583EW* Aurora Touch UPC Kit Instruction Guide. Aurora Touch UPC Kit Instruction Guide

UNIT CONTROLLER 8 (UC8) Troubleshooting guide

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING 2 INSTALLATION

SERVICE INSTRUCTIONS FUSION-TEC WALL-MOUNT AIR CONDITIONER

Feature Summary. I. System

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING 2 INSTALLATION. Premier Series

icomfort Residential Communicating Control System icomfort Touch Communicating Thermostat

CONTROL PANEL INSTRUCTIONS RSQ-4

WARNING Important Safety Information

INSTRUCTION MANUAL INSTALLATION OPERATION MAINTENANCE

User s Manual

EQUIPMENT PRE-STARTUP AND STARTUP CHECKLIST TEL NO: ORDER NO: CONTRACT NO:

CWS AIR-CONDITIONERS

Transcription:

Alarm Descriptions This document describes all possible alarm types as listed in the alarm log for software version 5.5.0 and later. x indicates compressor circuit for compressor related alarms. Alarms are listed in alphabetical order. All alarms can be manually cleared from the current alarms list. Note that if alarm is directly linked to a physical device (e.g. Blower Overload), clearing the alarm from the current alarm list will not clear the device if it still indicates a fault. A + sign by the timestamp in the alarm log indicates that the alarm has caused a lockout of related device and that alarm will not automatically be cleared. Clear alarm from current alarm list. Some alarms will not cause any type of stoppage and are merely there to notify end user that some type of maintenance is required. These alarms will be indicated using the Maint LED instead of the Alarm LED on the keypad. These type of alarms are referred to as alerts in this document. All alerts are still logged as alarms and also show up in the current alarm list. Battery The unit can detect a bad battery by comparing a set of configuration data stored in both battery backed up RAM and in Flash memory (not requiring battery to save data). If there is a mismatch in the data, the battery alaert will be tripped. You will always get this alert if a new core module with new software has been shipped out to replace faulty software in a unit since the battery is on the main board and not on the core module. Blower OL Blower overload. ComprLx Compressor low pressure fault. This alarm is tripped if low pressure is higher than Max suction pressure level. It can indicate that compressor motor running in reverse or some other serious compressor fault. The unit is looking at the trend of the pressure changing. For instance, if LP rise above Max pressure level but then starts dropping again, the alarm will not trip. Pressure has to rise or stay the same for at least 35 sec before alarm is tripped. AlarmDescriptions_5.6.0 Page 1 9/25/2011

ComprHx Compressor fault. This alarm is tripped if high pressure is less than Min discharge pressure level. It can indicate that compressor motor running in reverse or some other serious compressor fault. The unit is looking at the trend of the pressure changing. For instance, if HP drops below Min pressure level but then starts climbing again, the alarm will not trip. Pressure has to drop or stay the same for at least 35 sec before alarm is tripped. Cooler Compressor cooler fault. Either a LP, HP or Oil fault. All these sensors are wired in series for compressors used as pre-coolers. CoolFlt Compressor cooler fault at start attempt of cooler. If fault signal is not cleared within compressor anti block time, this alarm is tripped and cooler will not start. CWFault Chilled water fault. If there is a fault with chilled water circuit, this alarm is tripped. For instance, if a water flow switch has been installed, a bad water flow will cause this alarm to be tripped. DisTempHx Compressor discharge temperature is too high. Discharge temperature is above 230 F. This alarm trips as soon as the discharge temperature moves above 230 F. Exhaust1 Exhaust fan 1 overload alarm. Exhaust2 Exhaust fan 2 overload alarm. Filter Dirty Filter alert. Dirty filter schedule is used to trip this alert. By default it will be tripped every 4 months. Optionally a dirty filter switch can be installed to detect dirty filters. Dirty filter switch has to indicate a reduced airflow for more than 2 hours before alert is tripped. AlarmDescriptions_5.6.0 Page 2 9/25/2011

Fire Fire alarm for units wired up to a fire alarm. The unit is by default configured to require a manual reset of the alarm. Unit can be configured to automatically clear the alarm once the fire alarm clears. Freeze Freezestat condition. Supply air temperature has been below freezestat setpoint for more than 10 seconds. Alarm can also be tripped if unit has been equipped with a Freezestat sensor. When this alarm is tripped, all exhaust fans are stopped and outdoor air dampers closed. Freeze2 Level 2 freezestat condition. If the supply air temperature remains below freezestat setpoint 90 seconds after the first freezestat alarm, this alarm will be tripped. At this point the main blower will also be stopped. HeatRecOL Heat recovery pump overload alarm. HPx-P1 High Pressure fault by either pressure switch or transducer shortly after pool 1 heating solenoid has opened. Probable cause for HP trip is not enough water flow through pool water heating coil. HPx-P2 High Pressure fault by either pressure switch or transducer shortly after pool 2 heating solenoid has opened. Probable cause for HP trip is not enough water flow through pool water heating coil. HPx-PD High Pressure fault by either pressure switch or transducer when compressor is pumping down. HPx-SW High Pressure Switch fault. Switch trips at 350 psi for R-22 and R-407C and at 500 psi for R-410A. HPx-TD High Pressure transducer fault. Transducer is set to trip at 340 psi for R22 refrigerant, 360 psi for R-407C and 480 for R-410A. AlarmDescriptions_5.6.0 Page 3 9/25/2011

HPRelief Unit has initiated High Pressure Relief mode. This is an alert and will not cause any stoppage, just a temporary change in operation. In a pool unit this means that the pool heating solenoid has been opened even if there currently is no pool heating demand. There still is an upper limit for how hot unit will let the pool water to get. Unit will run in this mode for a limited time. In an OA unit, this means that the pre-cooler will be started if it is not running. The precooler will start as if it was started on a regular demand. It will be turned off once there is less of a demand (i.e. OA wet bulb has dropped below calculated setpoint). LPx-SW Low Pressure switch. Switch trips at 25 psi for R-22 and R-407C refrigerant and at 50 psi for R-410A. LPx-TD Low Pressure transducer. Transducer trips at 40 psi for R-22 and R-407C refrigerant and 75 psi for R-410A. LPx-Sens The first step in starting up compressor is to open pump down valve and wait for the low pressure to rise above LP start level. If this does not happen within the anti block timer and LP switch still indicates a LP fault, this alarm is tripped. Possible sensor faults or compressor very low on refrigerant. LPx-Vac Low pressure is reaching vacuum level. At startup of the compressor, the low pressure alarm is disabled to avoid tripping on low pressure in case of a big dip in pressure at startup. This alarm is to prevent the pressure from dipping too low. It is set at 20 psi for R-22 and R-407C refrigerant and 40 psi for R-410A. No Air No air flow alarm. If airflow switch has indicated reduced air flow for more than 2 minutes, this alarm is tripped. OACC1 OL Outdoor air condenser 1 overload alarm. OACC2 OL Outdoor air condenser 2 overload alarm. AlarmDescriptions_5.6.0 Page 4 9/25/2011

Oilx On units with an oil failure switch, this indicates a compressor oil failure. PumpFault Water flow fault for internal pump on Protocol units. Purge Too cold to use purge. Return air sensor has dropped below purge setpoint when purge is running. Purge will be stopped. SucTempHx Compressor suction temperature is too high. Suction temperature has been above 80 F for more than 5 minutes. SupHeatx Compressor superheat is too low. Superheat has been below 18 F (default) for more than 5 minutes. SWErrXM Internal software fault related to extended memory handling. SWErrEvt Internal software fault related to event handling. SWErrTm Internal software fault related to timers. SWErrSys Internal software fault related to system support functions. SWErrSP Internal software fault related to propriety Seresco Protocol. SWErrVT Internal software fault related to ValueType object. Volt Mon Voltage Monitor fault. Voltage monitor has detected a voltage fault. The alarm is cleared once the voltage monitor fault status is cleared. AlarmDescriptions_5.6.0 Page 5 9/25/2011

Waterflw1 Pool 1 water flow fault. If compressor trips on HP shortly after pool heating solenoid is opened, there will be two alarms logged. First one is a HP fault with pool heating as possible cause. The HP alarm will clear after alarm min stop time and compressor will try to run again. The second alarm is the Waterflw1 alarm that will lockout pool water heating for 60 minutes. Waterflw2 Same as the Waterflw1 alarm but for a 2 nd pool. WtrFlwHi1 High water flow alert. This is too alert you that the pool water flow is too high causing a too small differential between the pool in and pool out sensor. There will be no stoppage in pool water heating but if left unattended for a long time it can cause erosion in the water pipes. The pool out min level is used to determine minimum differential. Note that for 2 compressor units when only one compressor is running, the minimum differential is half of the specified min level. WtrFlwHi2 Same as the WtrflwHi1 alarm but for a 2 nd pool. WtrHot1 Pool water temperature too hot. If pool out sensor reaches 115 F, this alarm will be tripped. Pool water heating will be locked out for 60 minutes as for the Waterflw1 alarm. WtrHot2 Same as the WtrflwHi1 alarm but for a 2 nd pool. AlarmDescriptions_5.6.0 Page 6 9/25/2011