Refrigeration Cycle Demonstration Unit R633

Similar documents
Refrigeration Cycle Demonstration Unit R634

P.A. Hilton Ltd. Figure 2: HC655A Optional Computer Linking Upgrade

Air & Water Heat Pump R832

Mechanical Heat Pump R515

Vapour Jet Refrigerator / Heat Pump R853

Bench Top Cooling Tower H893

A660 Air Conditioning Laboratory Unit

Ventilation Trainer B500

Heat Transfer Service Unit H112

PERFORMANCE OF DEEP FREEZER BY USING HYDROCARBON BLENDS AS REFRIGERANTS

cussons Refrigeration Assembly Range TECHNOLOGY REFRIGERATION AND AIR CONDITIONING CUSSONS TECHNOLOGY LABORATORY RECOMMENDATION

EXPERIMENTAL INVESTIGATION OF WATER COOLER SYSTEM BY USING ECO-FRIENDLY REFRIGERANT (R-134a)

ME 354 THERMODYNAMICS LAB THE REFRIGERATION CYCLE

Refrigeration Technology in Building Services Engineering

SBS5311 HVACR II Experiment 2: Analysis of the Combined Rankine and Vapour Compression Cycle

An Experimental Study of a Simple Vapour Compression Refrigeration System with Varying Parameters

PERFORMANCE OF VCRS SYSTEM WITH HEAT EXCHANGER AND PHASE CHANGE MATERIAL

Thermodynamic Calculations of Two-Stage Vapor Compression Refrigeration Cycle with Flash Chamber and Separate Vapor Mixing Intercooler

Experimentation and Fabrication of Iceplant Using Ecofriendly Refrigerant

AN EXPERIMENTAL STUDY OF A REFRIGERATING PLANT WHEN REPLACING R22 WITH HFCs REFRIGERANTS

THERMODYNAMICS STEAM P7690 AND STEAM BENCHES CUSSONS TECHNOLOGY LABORATORY RECOMMENDATION

Role of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

A Review of Hydroflorocarbons (HFC S) Refrigerants as an Alternative to R134a Refrigerant

Experimental Study on Performance Parameters for Refrigerants R22, R410a and R404a at Various Air Outlet Temperatures

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

Available online at ScienceDirect. Energy Procedia 109 (2017 ) 56 63

Pressure Enthalpy Charts

DIRA S.L. (Desenvolupament, Investigació i Recerca Aplicada S.L.)

Simple Compression Refrigeration Circuit Unit TSCR

Transcritical CO2 Bottle Cooler Development

International Journal of Informative & Futuristic Research ISSN (Online):

CHAPTER 1 INTRODUCTION

Design of LPG Refrigeration System

Performance Analysis of Electronic Expansion Valve in 1 TR Window Air Conditioner using Various Refrigerants

CO 2. ECO Water Heaters. Energy efficient and environmentally friendly water and space heating. SANYO Air Conditioners. The natural choice.

U.G. Student, Department of Mechanical Engineering, J D Engineering College, Nagpur, Maharashtra, India

Sarthak Thakar, 2 R.P.Prajapati 1

REFRIGERATION CYCLE Principles of Mechanical Refrigeration Level 2: Cycle Analysis

LPG Refrigerator. October 2017 IJIRT Volume 4 Issue 5 ISSN:

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

II. OBJECTIVE OF RESEARCH

Modular Air Cooled Scroll Chillers

Introduction of Transcritical Refrigeration Cycle Utilizing CO2 as Working Fluid

AQUASNAP JUNIOR 30RHV

Energy Use in Refrigeration Systems

Subscripts 1-4 States of the given system Comp Compressor Cond Condenser E Evaporator vol Volumetric G Gas L Liquid

Experimental performance evaluation of heat pump by using CO 2. as a refrigerant. IOP Conference Series: Materials Science and Engineering

EREBA ACCESS. Easy and fast installation Hydronic module available Compact, reliable and efficient USE RANGE CONFORMITY

Thermodynamic study of R134a in Vapour Compression Refrigeration System in Summer Climate

2. CURRICULUM. Sl. No.

COLD. Basic Training Course II. November ESSE - Wilhelm Nießen

Performance Assessment of Water Cooled Condenser Refrigeration System

EVALUATION OF REFRIGERANT R290 AS A REPLACEMENT TO R22

Combination unit to support instruction in Thermodunamics, Fluid Mechanics, and Heat Transfer

SWIMMING POOL HEAT PUMPS

VAPOR COMPRESSION HEAT PUMP USING LOW TEMPERATURE GEOTHERMAL WATER: A CASE STUDY OF NORTHERN THAILAND

Experimental study of Hydrocarbon Refrigerant Mixture R290/R600a as an alternative to Refrigerant R134a used in a Domestic Refrigerator

A Theoretical investigation on HC Mixtures as Possible Alternatives to R134a in Vapor Compression Refrigeration

REFRIGERATION AND AIR CONDITIONING

Thermodynamic analysis of air cycle refrigeration system for Chinese train air conditioning

Performance and Analytical Study of Cooler Cum Air Conditioner based on Vapour Compression Refrigeration System

we will examine only the vapour compression systems transfers to the Carnot cycle can serve as the initial model of the ideal refrigeration cycle.

Design & Fabrication of Hybrid Cooler

Refrigerant Dryers DRY with PDP Indicator

EXPERIMENTAL INVESTIGATION ON VARIABLE SPEED OPERATION OF AIR CONDITIONING

Main Anthropogenic Sources of Greenhouse Gases Refrigerants

ASSESSMENT OF R430A REFRIGERANT AS A POSSIBLE SUBSTITUTE TO R134A REFRIGERANT IN LARGE CAPACITY FREEZER

Thermodynamics I. Refrigeration and Heat Pump Cycles

30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation

EXPERIMENTAL INVESTIGATIONS ON AUTOMOBILE AIR CONDITIONERS WORKING WITH R134a AND R290/R600a AS AN ALTERNATIVE

International Journal of Research in Engineering and Innovation Vol-1, Issue-5 (2017), 68-72

AIR TO WATER HEAT PUMPS SPECSHEET

Paper No. : 04 Paper Title : Unit Operations in Food processing Module 11 : Principles of Refrigeration

Chapter 2. Alternatives to HCFCs and their Characteristics

CHAPTER 1 INTRODUCTION

LAB EQUIPMENT DETAILS

Development of a Psychrometric Test Chamber. Michael J. Swedish. Associate Professor Mechanical Engineering Department Milwaukee School of Engineering

REPLACING HARMFUL CFC 12 BY ECO-FRIENDLY REFRIGERANT IN MILK CHILLER

Experimental Investigation of a New High Temperature Heat Pump Using Water as Refrigerant for Industrial Heat Recovery

COMPARATIVE PERFORMANCE ANALYSIS OF EXPERIMENTAL FRIGORIFIC AIR CONDITIONING SYSTEM USING R-134A AND HFO-1234YF AS A REFRIGERANT

Department of MCE, Islamic University of Technology 2. Abstract

Brazed Plate Heat Exchanger for CO Applications

Math. The latent heat of fusion for water is 144 BTU s Per Lb. The latent heat of vaporization for water is 970 Btu s per Lb.

ENVIRONMENT FRIENDLY CLIMATIC CHAMBER

A: RS-45 is a non ozone depleting Drop-in replacement for R22 in most applications. A: RS-45 is a blend of R143a, R125, R134a and isobutane.

ISSN Electronic International Interdisciplinary Research Journal (EIIRJ) Bi-monthly Reviewed Journal Mar- April 2015

3. (a) Explain the working of a rotary screw compressor. [10] (b) How the capacity control is achieved in refrigerant compressor?

CH2351 Chemical Engineering Thermodynamics II Unit V Refrigeration. Dr. M. Subramanian

Heat Transfer Analysis of Vapor Compression System Using Nano Cuo-R134a

Waste Heat Utilization of Vapor Compression Cycle for Operation of Vapor Absorption System

DEEPAK PALIWAL, S.P.S.RAJPUT

OIL SEPARATORS APPLICATIONS

CHAPTER 7 PERFORMANCE ANALYSIS OF VAPOUR COMPRESSION REFRIGERATION SYSTEM IN HYBRID REFRIGERATION SYSTEM

Lab 1b Cooling Tower Performance and Sensors for Thermal-Fluid Systems

IJISET - International Journal of Innovative Science, Engineering & Technology, Vol. 2 Issue 12, December

THERMAL ENGINEERING LABORATORY II. To train the students with principles and operation of thermal Engineering equipments.

DEVICE FOR EXTRACTING WATER FROM AIR

Experiment 12 Shell and Tube Heat Exchanger. Aim of this Experiment

Sweden s leading air source heat pump

Transcription:

Refrigeration Cycle Demonstration Unit R633 Figure 1: R633 Unit Ozone friendly, low pressure, non-toxic working fluid allows evaporation and condensation to be seen in glass cylinders. A Bench top unit specifically designed for unsupervised operation. Fast response to controls allows efficient use of laboratory time. Negligible operating and maintenance costs. Two-year warranty. Page 1

Experimental Capabilities Demonstration of the vapour compression refrigeration and heat pump cycle with visual observation of all-important processes. Investigation and demonstration of the pressure-temperature relationship during evaporation and condensation. Demonstration of: - Charging Pumping over or pumping down the refrigerant charge into the condenser. The effect of air in refrigeration systems. Determination of effect of evaporating and condensing temperatures on the refrigeration rate and condenser heat output. Investigation of the effect of compressor pressure ratio on system performance. Determination of overall heat transfer coefficient in a simple shell and tube type heat exchanger. With the addition of the optional temperature indicator R633A: - Development of a refrigeration cycle diagram on a pressure - enthalpy chart. With the addition of the optional digital wattmeter R633B: - Measurement of the electrical power used to drive the vapour compression refrigeration and heat pump cycle. Insert 1: Optional Digital Temperature Indicator upgrade. R633A Insert 2: Optional Digital Wattmeter Upgrade R633B Page 2

Special Design Features Specifically designed for safe unsupervised operation by students. Low-pressure non-toxic working fluid R141b enables both evaporation and condensation to be safely observed in glass components. Very Low ODP (0.1) working fluid using components that will be supportable well into the next millennium. Self contained bench top unit requiring only minimal electrical power and cooling water. Visual impact of the unit aids student understanding of a complex process. Low thermal inertia allows a large range of experiments to be carried out in a short period. Optional factory, or user fitted, upgrades to give digital temperature readout (R633A) and compressor electrical power consumption (R633B). Description The vapour compression refrigeration and heat pump cycle is of paramount importance in food and drug preservation, air conditioning, heat pumps as well as other industrial and commercial process. The importance of the efficient and safe use of refrigeration systems has now been added to by the problems of ozone depletion and global warming. It is therefore more essential than ever before that students have a thorough understanding of both the practical aspects of refrigeration and the thermodynamic processes affecting the performance of the cycle. Often the most difficult aspect for new students to grasp is the process of evaporation at low pressure and condensation at high pressure. By utilising a non-toxic working fluid with a low vapour pressure, the evaporation and condensation processes are clearly visible in thick walled glass chambers. The evaporator consists of a closed, thick walled glass chamber containing a pool of R 141b into which is immersed a specially treated copper coil. An hermetic compressor draws vapour from the evaporator and compresses this before discharging it to the condenser. The reduction in evaporator pressure causes the refrigerant to boil, so extracting heat from the water flowing through the coil and generating more vapour to be drawn into the compressor. From the compressor the high-pressure vapour passes to the condenser, which is of similar construction to the evaporator but contains a nickel-plated water-cooled copper coil. Vapour condenses on the surface of the coil and falls to the bottom of the chamber. The heat given up by the refrigerant phase change is transferred to the cooling water flowing through the cooling coil. A float controlled expansion valve at the base of the condenser chamber controls the flow of high pressure refrigerant liquid returning to the evaporator. After passing through the expansion valve the refrigerant expands to form a liquid vapour mixture at the same pressure as the evaporator and the cycle is repeated. The standard instrumentation fitted enables measurement of the condenser and evaporator pressures and temperatures as well as water flow rates and water temperatures. The condensing and evaporating pressures are varied by adjustment of the water flow rate to the evaporator and condenser coils using integral control valves on individual flowmeters. An optional Digital Temperature Indicator Upgrade R633A, allows the measurement of the above temperatures plus the compressor discharge and condensed liquid temperatures to 0.1 C resolution. The addition of these parameters allow a complete refrigeration cycle diagram to be plotted on an R141b Pressure-Enthalpy Diagram. An optional Digital Wattmeter Upgrade R633B allows measurement of the instantaneous electrical power being consumed by the compressor. Range 0-1999W resolutions 1 W. Page 3

Figure 2: Data showing pressure temperature relationships for refrigerant Figure 3: Data showing the effect of air in refrigeration systems Page 4

Specification General Refrigeration Cycle Demonstration Unit with low-pressure non-toxic refrigerant and water cooled cylindrical glass evaporator and condenser. Detailed A bench mounted vapour compression refrigeration cycle demonstration unit using a hermetic compressor and water cooled flooded glass condenser and evaporator. Unit operates on low-pressure non-toxic ozone friendly refrigerant. Internal electrical and mechanical safety devices allow for unsupervised operation by students. Standard instrumentation fitted enables measurement of the condenser and evaporator pressures and temperatures as well as water flow rates and water temperatures. Unit supplied with a detailed experimental operating and maintenance manual giving example experimental results and sample calculations. Equipment supplied with spares and accessories for two years normal operation together with a full two-year warranty. Further specification details available on request An optional digital temperature indicator upgrade allows measurement of all system temperatures to 0.1 C with the addition of compressor discharge and condensed liquid temperatures so enabling a cycle diagram to be drawn on a Pressure-Enthalpy chart. Services required Electrical: A: 220/240 Volts Single Phase 50Hz (with earth/ground). Line current up to 4.5 A at 230v. B: 110/120 Volts Single Phase 60Hz (with earth/ground). Line current up to 9.0 A at 115v Water: 6 litre/minute at a minimum of 28m head. Ordering Information Order as: And: And: Refrigeration Cycle Demonstration Unit. R633 Optional Digital Temperature Indicator Upgrade. R633A Optional Digital Wattmeter Upgrade. R633B Electrical Specification Either: A: 220/240V Volts Single Phase 50Hz (with earth/ground) B: 110/120 Volts Single Phase 60Hz (with earth/ground) Shipping Specifications Net Weight: 64kg.(220/240v) 71kg(110/120v) Approximate Gross Weight: 100kg. (220/240v) 107kg. (110/120v) Packing Case Dimensions: 0.92 x 0.65 x 1.05m Packing Case Volume: 0.63m 3 Accessories and Spares Unit supplied with: One experimental operating and maintenance manual in English, French, or Spanish (Other languages on request). Accessories and spares for 2 years normal operation. Also available: Recommended list of spares for 5 years normal operation. P A Hilton Ltd. Horsebridge Mill, King s Somborne, Stockbridge, Hampshire, SO20 6PX, England. Telephone: National (01794) 388382 International +44 1794 388382 Fax: (01794) 388129 E-mail sales@p-a-hilton.co.uk Page 5