TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Ultra Low NOx PowerVent with Honeywell Electronic Control California Only

Technical

Technical


New Power Vented Rheem FVIR Tanks

Technical

OWNER S MANUAL Manufactured Home Downflow Gas Furnace: MGD-B Series

A.O. Smith Water Products Company

CAUTION WARNING. 50T Integrated Furnace Control INSTALLATION INSTRUCTIONS DESCRIPTION PRECAUTIONS

21D83M-843 Integrated Single Stage Furnace Control Replacement Kit INSTALLATION INSTRUCTIONS

DC50X2 Models 50 Pound Stacked Commercial Dryer. Troubleshooting,Fault Codes, and Schematics. Starting serial number Part # /13

Guardian PowerVent Training Manual. Flammable Vapor Ignition resistant (FVIR) compliant PowerVent water heater manufactured after 1 January 2006

Operator: Save these instructions for future use!

Operator: Save these instructions for future use!

AXIAL HEATER TROUBLE SHOOTING GUIDE. Models: AX24 N/PV, AX24 N/PV LT, AX24 LP AX26 N/PV, AX26 N/PV LT, AX26 LP AX28 N/PV, AX28 N/PV NT, AX28 LP

COMMERCIAL GAS WATER HEATERS

Service Handbook COMMERCIAL GAS HIGH EFFICIENCY WATER HEATERS

50M56U-843 INSTALLER MUST READ DESCRIPTION PRECAUTIONS WARNING CAUTION

Operator: Save these instructions for future use!

Figure 10 or Figure 6

No. Of Ignition Trials: No. Of Re-Ignition Attempts. Reset by interrupting power for 5.0 Seconds. Diagnostic Output. Re-Ignition Limit Exceeded

Operator: Save these instructions for future use!

Dexter Commercial Vended Stack Washer Dryer. Dryer Troubleshooting, Fault Codes, And Schematics. Starting serial number (12/13)

WARNING WARNING TROUBLESHOOTING GUIDE INTEGRATED FURNACE CONTROL MODULE

Service Handbook COMMERCIAL GAS HIGH EFFICIENCY WATER HEATERS

50M56U-843 Universal Single Stage HSI Integrated Furnace Control Kit INSTALLATION INSTRUCTIONS

XIII Troubleshooting

50M Integrated Single or Two-Stage HSI Integrated Furnace Control Kit INSTALLATION INSTRUCTIONS

50A Integrated Furnace Control

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power.

Internet Version for Reference Only INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART #

Hot Surface Ignition (HSI) System Booklet

50A Integrated Furnace Control

Operator: Save these instructions for future use!

INSTALLATION INSTRUCTIONS FOR SERIES 9 INTERMITTENT PILOT IGNITION CONTROL

AGP. (All Grade Pellet) Troubleshooting Guide Document Copyright 2017 Travis Industries Certified Factory Training Program

SERVICE MANUAL. Ultra High Efficiency Models with Direct Spark Ignition. Gas Water Heaters. Troubleshooting Guide and Instructions for Service

Technical by adjusting

Service Manual Model 3163

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power before servicing, unless testing requires power.

Interrupted Ignition Series Oil Primary Control

LATTNER BOILER COMPANY 9.5 HP Low-NOx Installation and Start-Up Checklist for Dry Cleaners

Dexter Industrial On Premise Dryer. Troubleshooting, Fault Codes, And Schematics. Starting serial number Part # /13

Operator: Save these instructions for future use!

DF400/DF600. Construction Heaters. Installation and Maintenance Manual

95M-200. Gas-Fired Direct Vent Modulating Hot Water Boiler. Control Manual And Troubleshooting Guide. P/N , Rev.

Heat Pump Defrost Board Replacement Kit

HT-2 / 9600 Series Control Contents

SUPER HIGH EFFICIENCY WATER HEATERS SUPPLEMENT TO INSTRUCTION MANUAL P/N (Replaces pg. 2 in instruction manual.) CONGRATULATIONS!

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power.

TECHNICAL SUPPORT: SERVICE BULLETIN #4 (v ) AB2017 HOT SURFACE IGNITION MODULE OVERVIEW

MSPA-MP METAPACK SERVICE MANUAL. Visual step-by-step guide to easily identify & correct technical problems! Gecko Electronics Inc.

AWEIS Troubleshooting Guide Table of Contents

BGH Series Hot Surface Ignition Control

prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE TSG-SOLO-9/04

WC Series Vended Washers Troubleshooting, and Fault Codes

SERVICE MANUAL. Ultra Low NOx Atmospheric Vent Water Heaters with Direct Spark Ignition. Troubleshooting Guide and Instructions for Service

Operator: Save these instructions for future use!

Eclipse Self-Check UV Scanner

CLOTHES DRYER Technical Information

SERVICE MANUAL. PV Series. Power Vent Gas Water Heaters. Troubleshooting Guide and Instructions for Service. Models Covered by This Manual:

Bosch 80% AFUE Gas Furnace BGS80 Model

CLOTHES DRYER Technical Information

User s Information Manual Lynx Direct-Vent Sealed Combustion Condensing Boiler Model LX-90, LX-120, LX-150

SERVICE MANUAL. PDV Series. Power Direct Vent Gas Water Heaters. Troubleshooting Guide and Instructions for Service. Models Covered by This Manual:

100T399-SOLA SUPPLEMENT TO INSTALLATION & OPERATION MANUAL INCLUDED WITH WATER HEATER (SERIAL NUMBERS BEGINNING LK AND LATER)

SERVICE MANUAL. Residential D Series. Gas Water Heaters. Troubleshooting Guide and Instructions for Service. Models Covered by This Manual:

Oil Miser 148, Second Warning Lamp

Electronic Ignition Water Heater

SERVICE MANUAL. Ultra Low NOx Residential D Series. Gas Water Heaters. Troubleshooting Guide and Instructions for Service

SERVICE MANUAL. TTW Series Through-The-Wall Gas Water Heaters. Troubleshooting Guide and Instructions for Service. Models Covered by This Manual:

1. GENERAL SAFETY RULES

FLAME115 INFRARED HEATER SERVICE MANUAL INDEX FIRE 115 WARNING

Condensing Models. On-Demand Water Heater Service Handbook

7800 SERIES Relay Modules

Test/Function Wrinkle release. Display list of diagnostic codes. Then press Temperature (^) - 13 Key. To sequence thru the diagnostic and help codes.

IFT-RC150 IntelliFire Touch Remote Control Installation Instructions

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

PDV(S,T) MODEL SERIES AND INDUCED DRAFT (D80T725, D65T625) MODEL SERIES WATER HEATERS WITH HONEYWELL INTEGRATED CONTROL SYSTEM

Revision B Printed Fall Elston Manufacturing HC Heater Owners Manual

An occurrence of an Error will make a sound of error melody for 5sec and continuously show one of the Error Displays from the following errors.

Each heater has slightly different operational characteristics

SERVICE NOTEBOOK VIPR (DOWNDRAFT)

Heating Basics Gas Valve Systems

24 VAC Intermittent Pilot Gas Ignition Control

24 VAC Direct Spark Gas Ignition

SLP98UHV WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

NOTICE . SAFE SERVICING PRACTICES. Electric Wall Oven with Electronic Oven Control

R7910A SOLA (Hydronic Control) and R7911 SOLA (Steam Control) Systems

59MN7A Series 100 TROUBLESHOOTING GUIDE

prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE TSG-PRESTIGE Date revised: 11/10/08

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

CONVERSION MANUAL CAUTION

Q - Series Boiler. Troubleshooting Manual

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVN/P-400 INDIRECT FIRED SPACE HEATERS

Control manual and troubleshooting guide

SERVICE MANUAL. Ultra Low NOx Atmospheric Vent Gas Water Heaters. Troubleshooting Guide and Instructions for Service. Models Covered by This Manual:

SERVICE MANUAL. Ultra Low NOx Atmospheric Vent Models. Gas Water Heaters. Troubleshooting Guide and Instructions for Service

A-1106 ACCESSORY KIT INSTALLATION INSTRUCTIONS IGNITION CONTROL P/N S , S , S

Transcription:

NOx 75 & 98 Gallon This technical bulletin applies to the 75 and 98 gallon NOx residential product manufactured for the California market. No Power or No Blower Motor Nothing happens at all. No blower motor; no sounds. y There iss not a display code for this problem. 1. Check wall plug power with a table lamp. 2. Check that the unit is plugged in. 3. Verify blower motor switch is ON. 4. Verify 120VAC power to the control thru the yellow wire on the gas control valve Molex. You should be able to wake up the control by holding down the red and blue arrow keys at the same time. Adjust water temp to 120 0 F. 5. Verify power to the blower at the black wire on the Molex. Replace blower if there is power on the black wire, but no blower motor. Replacee control if no power on black wire. Blinking Control Lights y The display lights on the gas valve blink. This error code The display lights should never blink. If the valve is caused by loss of neutral to control. operatess properly, there are no light on. If the valve is in error mode, the indicator lights are solid on. 1. Verify Molex connections at the gas control are tight. 2. Verify 120V across hot and neutral leg of wall outlet. 3. If do not have 120V the issue is the wiring inside the home/business. 4. IF 120V has been confirmed at wall outlet, check for 120V across hot (Yellow) and neutral (White) at control. If have the 120V then control is bad. 5. If you do not have 120V at gas control then replace blower assembly and power cord. 1440 75-98 gal ULN.docx Page 1 of 9

NOx 75 & 98 Gallon Error 1 An open earth ground circuit to the water heater. y 1. Check that the earth ground conductor is properly connected at the fuse box or breaker panel and the water heater. 2. Check that the grounding conductors on the water heater are properly connected and secure. 3. Check green grounding wire connection on side of control valve. Error 2 The self diagnostic test detected a wiring error or a high resistance to earth ground. y 1. Check for proper connection of the line neutral and line hott wires. 2. Check that the appliance is securely connected to earth ground. Error 3 y The pressure switch remained closed longer than 5 seconds after the call for heat began. This error code will appear within 5 seconds if the pressure switch will not open. 1. The pressure switch wiring is incorrect. 2. The pressure switch has been jumped. 3. The pressure switch is defective (contacts inside switch permanently closed) and must be replaced. 1440 75-98 gal ULN.docx Page 2 of 9

NOx 75 & 98 Gallon Error 4 The pressure switch remained open longer than 5 seconds after the combustion blower energized. y 1. The pressure switch wiring is incorrect or disconnected. 2. The pressure switch tubing in not connected correctly or pinched off. 3. Obstructions or restrictions in the water heater exhaust venting. Remove venting and recycle to rule out venting. If unit goes to main burner, the venting is the problem. If the code repeats, replace inducer/pressuree switch. 4. The vent over-temperature switch if activated or defective. Error 5 The self-diagnostic test has detected an error in the Hot Surface Igniter circuit. Verify @70-90 VAC to the HSI at the #1 and #2 pins of the Molex. y 1. Check that the wiring harness Molex is connected and secure. 2. Disconnect the ignitor connector and measure the ignitor resistance with an ohmmeter between pins 1 and 2. Resistance should be between 11.5 and 18.8 ohms. 3. If the reading is incorrect, replace the Hot Surface Ignitor assembly. 4. If the above checks are good, replace the Intelli-Vent control. Error 6 y The maximum number of ignition retries or recycles has been reached and the system is in lockout. (This means there was no flame rectification to the control to verify main burner.) 1. Check if the gas supply is off or too low to operate. 2. Check the flame sense rod to see that it is located properly and free from contamination. Reposition the flame sense rod or lightly clean with an abrasive cloth. (Seee last page for positioning of flame rod.) 3. The Hot Surface Ignitor may not be positioned on the burner correctly. Reposition as necessary. (See last page for proper positioning of hot surface igniter and flame probe) 4. Low voltage to the water heater. (Verify the hot surface ignitor glows by recycling power and looking thru sight glass window. If you have a glowing ignitor, then your problem is probably Page 3 of 9 1440 75-98 gal ULN.docx

NOx 75 & 98 Gallon fuel related.) 5. Thermal Releasee Device is damage or missing. No oxygen in combustion chamber. 6. Inadequate fresh air to support combustion inside combustion chamber. 7. Main burner supply tube is blocked, bent or restricted; burner orifice is blocked or restricted. Error 7 The self-diagnostic test found a problem with the gas valve driver circuit. Note: There are no further tests to conduct when the control fails one of its self-diagnostic tests. If the valve thinks there is something wrong; then the recourse is to replace the control. Error 8 The self-diagnostic test found a problem with the internal micro computer Note: There are no further tests to conduct when the control fails one of its self-diagnostic tests. If the valve thinks there is something wrong; then the recourse is to replace the control. Error 9 The self-diagnostic test found a problem with the internal circuit Note: There are no further tests to conduct when the control fails one of its self-diagnostic tests. If the valve thinks there is something wrong; then the recourse is to replace the control. 1440 75-98 gal ULN.docx Page 4 of 9

NOx 75 & 98 Gallon Error 10 Flame signal sensed out of proper sequence. (The flame probe sensed the presence of flame when it was not supposed to.) Error 11 High temperature thermal cut-off (ECO) switch is tripped. (This one time use device trips when the water temperature exceeds 195 0 F.) Error 12 The self diagnostic test has indicated one of the temperature adjustment buttons is stuck closed. 1. Make sure that there are no objects leaning against the front of the control 2. Lightly press and release each of the buttons once. 3. If the above actions do not clear the error, the control will continue to regulate water temperature at the last setting, but you are not able to change settings unless you replace the Intelli-Vent TM control. Error 13 The self-diagnostic test has detected that the water temperature sensor is either open or short circuited. 1440 75-98 gal ULN.docx Page 5 of 9

NOx 75 & 98 Gallon Note: There are no further tests to conduct when the control fails one of its self-diagnostic tests. If the valve thinks there is something wrong; then the recourse is to replace the control. Error 14 The self-diagnostic test found a problem with the Flammable Vapor Sensor. (This is not a flammable vapor event. It may be caused by disconnecting the FV sensor Molex, or the FV sensor itself. This includes both short and open electrical connections.) 1. Check all FV sensor wiring harness connections; and the connections to the back of the sensor. 2. Cycle power to the water heater off for 10 seconds and thenn back on. 3. If no wiring problems are found, the Flammable Vapor Sensor must be checked. a. Disconnect the FV sensor Molex and measure the resistance of the sensor between the two black wires 2 and 3. If the resistance is less than 9k OHMS or greater than 45k OHMS, then replace the sensor. b. If the FV sensor is between 9K OHMS and 45K OHMS and the code will not clear by recycling power, replace the Intelli-Vent TM control. Error 15 The control detected the presence of flammable vapors near the water heater and entered lock out. This is a permanent lockout and cannot be cleared by cycling power. Control may be reset. 1. Disconnect the FV sensor Molex and measure the resistance of the FV sensor between the two black wires 2 and 3. 2. Write down this resistance and call the technical support line at 800-432-8373 for further instructions. 3. The control is field resettable; however, we probably need to replace the FV sensor if the sensor is out of tolerance. Page 6 of 9 1440 75-98 gal ULN.docx

NOx 75 & 98 Gallon White Rodgers Invensys Reset Procedure 1. Reconnect power to the water heater and turn the unit on. Within 5 seconds.. 2. Press and hold left and right arrow keys on the control valve, at the same time, until the green light begins to blink. 3. Release buttons and immediately 4. Press left and right temp adjustment keys in the following sequence: Left Right Left, Left Right Left Right, Right 5. If the error code is reset, all the lights will come on. The valve is now reset. You must complete all steps within 30 seconds. NOTICE: Do not attemptt to disconnect, jumper, obstruct or block the Flammable Vapor Sensor. If will cause an error code. 1440 75-98 gal ULN.docx Page 7 of 9

NOx 75 & 98 Gallon Wiring Diagram 1440 75-98 gal ULN.docx Page 8 of 9

NOx 75 & 98 Gallon Flame Sensor Rod Position The diagrams below show the proper placement of the flame sensor r rod for the ULN 75 and 98 gallon gas with the White Rodgers control. Top view Hot surface igniter should extend over closest row of burner tube holes. Flame rod should be centered in the middle of the burner tube holes. Side view distance from top of burner plate Flame rod should be positioned as shown. Distance from the bend in the flame rod to the burner tube is the width of a quarter (3/16 inch). 1440 75-98 gal ULN.docx Page 9 of 9