SIGMA MRL E1000.

Similar documents
Since giving rise to the elevator industry more than 150 years ago, Otis has been at the forefront of elevator technology.

The Elevator Control System

Hitachi Elevator VFI-II

REVA Linen Finish Car Operating Panel

SECTION ELECTRIC TRACTION ELEVATORS PART 1 GENERAL 1.01 SUMMARY. A. Section Includes: Electric Traction Elevators.

How the People Counter Works. Enhanced Safety, Security and Building Automation, and Improved Marketing Intelligence. 3D MLI Sensor Technology

SUSTAINED SAFETY DURABLE QUALITY

Small in size, with grand features USER GUIDE Elle-même petite, mais avec caractéristique grand

ELEVATOR UPGRADE AND MODERNIZATION

TrueCom. Building Communications Systems 5115-Series , Area of Rescue Communications System. Description

SAPLING HEALTHCARE SOLUTIONS

Fire Safety Policy & Fire Safety Management System Version October 2013 Emergency Evacuation Procedures

Authentic Art Deco apartment complex. Bespoke lifts bring easy access. 30s style + 21st-century action = smoother circulation for all.

Schindler HXpress An efficient, affordable modernization for hydraulic elevators

The Windcrest Remote Alarm for Passenger and Goods Lifts with Optional BS EN81-28 & BS EN81-70

Sensors and Switches in Commercial Traction Elevators

Aviation Solutions. Why Tyco for airports? Our systems help protect over 110 airports. Secures over 80% of UK Airports and more than 60 US Airports

APPENDIX K MODIFIED INDUSTRY STANDARDS FOR ELEVATORS AND CONVEYING SYSTEMS

TD flex is an award-winning tailgate detection solution that prevents unauthorized access at: Doors Mantraps Airlocks E-gates Turnstiles

FALCO Access Control. Product Training

PAMA PRODUCT PASTEURIZATION, HEATING AND COOLING SYSTEMS

GREEN LIFT SYSTEM USE MANUAL WITH PERMANENT MAGNETS * EN* SYSTEM TYPE: q GLPM MRL 1:1 q GLPM MRL 2: EN.

Port of Portland Conveying Equipment Guidelines

MECKLENBURG COUNTY FIRE MARSHAL S OFFICE

Summit 3208GLD USER MANUAL. Electronics Line

Introduction Limited-Use / Limited-Application

TST Portable Event Logger &Programmer for UML-51 Controllers v15.6

Basic Installation Manual

Building Integration System. Your platform for customized security and safety management.

SAPLING EDUCATION SOLUTIONS

PMD2 Plus/EZHD. Elliptic, Multi-Zone and Heavy Duty

Home Elevators for Private House

User s Manual and Warranty Information ThyssenKrupp Access

rpsa FIRE PROTECTION ENGINEERS

VIDEO INTERCOM SYSTEM

PRODUCT TRAINING MODULE: Linear Hall-effect Sensor ICs SS39ET, SS49E, SS59ET Series

The Next Generation Machine Protection System

AT8060 BREATH ALCOHOL TESTER USING MANUAL. Ver: HW Catalogue

User s Manual and Warranty Information for Counterweighted Chain Drive ThyssenKrupp Access

BTICINO HOME AUTOMATION. THE NATURAL EVOLUTION OF YOUR HOME.

Installation of a new engineered HYDRAULIC elevator complete as described in this standard.

A Smart & Integrated Security solution

LYNX Touch Security System

N-8000 SERIES IP INTERCOM SYSTEM

Gallagher System Integrations

Interactive Catalog Replaces Catalog Pages

SILENCING AN ALARM When the alarm bell or siren is sounding, enter your user code or present your SecuraProx fob to your keypad.

AlertWave Smart Wireless Solutions for Today s Campus Whether you are a large university

A new view on building protection. Cerberus DMS makes building protection smarter, easier and more flexible. Answers for infrastructure.

WORLD CLASS SOLUTIONS TO A UNIVERSAL CHALLENGE EST LIFE SAFETY PRODUCTS DETECTORS AND MODULES ... EDWARDS SYSTEMS TECHNOLOGY

ADVISOR CD User Manual. Software from version: V

Provisions for the Means of Escape and Means of Access by Using Lifts and Escalators in the MTRC Main (U/G) Station

ELEVATORS. Integration of Codes between Fire Alarm, Sprinklers, and Elevators 12/5/2017

ADRIA intelligent room system

L900 series USER MANUAL

KONE AMD Doors and Entrances. Architectural design Information

User's Manual. and Warranty Information. ThyssenKrupp. ThyssenKrupp Access

University of Toronto Section Technical Design Standards for Division 14 February 2015 DIVISION 14 - ELEVATOR DESIGN STANDARDS

Product Brochure Low-profile air handling units ATpicco. Modular configuration with highly efficient energy recovery

Fixed Speed Rotary Screw Compressors UP6S Series hp (11-22 kw)

Using Your. Security System With LED Keypad S5030, S5031, S5032

Security Solutions From The Masters In Electronic Security Systems

THANK YOU FOR VOTING TEXECOM USER GUIDE. Security Control Panels

TITLE RS20i Atmos & DTS:X Decoder Card (H693) Setup

Emergency Power & Fire Service Checklist

VIDEO INTERCOM SYSTEM SEEING IS COMMUNICATION

AVCOM System Installation Instructions

rvm4c Installation Guide Remote Video Module

02PN20/EZHD ELLIPTIC, MULTI-ZONE AND HEAVY DUTY ENHANCED METAL DETECTOR

Access Control for. Part 3 of 4. Brought to You by. Presented by Video Security Consultants

VX-2000 SERIES INTEGRATED VOICE EVACUATION SYSTEM

V1.0. Smart Home Alarm System. User Manual. APP download via QR Code scanning. Please read the manual carefully before using.

Access Control. Total Perimeter Protection Solutions from one Source

Presentation Material: The material will be presented in a PowerPoint format and available digitally/ paper.

DMTF: Specific Building Recommendations

PMD2 Plus/EZHD. Elliptic, Multi-Zone and Heavy Duty. Superior Detection and Throughput. Very High Discrimination of Non-Threat Items

AIR TREATMENT. ReCOOLER HP» INTEGRATED COOLING/HEATING FUNCTION WITH REVERSIBLE HEAT PUMP IN THE eq AIR HANDLING UNIT

LHCb Rich Detectors Control and High Voltage Systems

The Bridgewater Hall

Interfaces with many electrical components without buffering Thermally balanced integrated circuit for stable operation over a full temperature range

Security GSM Alarm System

Get more out of tubes

VAC PLC. System Description

Elevators Revision 01/04/2019

Standard of Practice - Fire Alarm Systems. NOTE: Significant revisions or additions to the previous standards are highlighted in italics.

DESCRIPTION OF KEYPAD (Access module with segments)

Versatile large and small-piece feeder. Jenfeed Logic S. 1-lane large-piece feeder for mixed production of table linen and bed linen

Solutions for Mass Notification Systems

Simplex Panel Interface Guide

Schindler 6200/6300 Décor lines, colors and materials.

Contents. 30 References

2000 Series. Program Entry Guide. Control Panels

Memphis Housing Authority High Rise Fire Alarm Upgrades. Questions from Contractors (Through Addendum #2) Communications Systems, Inc.

HARDwired Installation/ Owner s Manual

HCD DSA OSHPD 1 2 1/AC AC SS SS/CC

Schindler 5500 Design lines, colours and materials. Design that speaks to your senses.

Security System. User Guide for the LED Command Center

Simplify. Secure. Your Home. Your Life. M1 Security & Automation Controls

EM4 APPLICATIONS EXAMPLES

MAY 2016 Elevator QEI & Maintenance Performance Report

Transcription:

SIGMA MRL E www.sigmaelevator.com

Lifting up Trust Our dedication and passion to reach customer satisfaction always have been a driving force of our creative and innovative ideas. As your elevator partner, upgrading our ideas in providing comfortable elevators to our customers, at the same time, devoting ourselves in protecting environment are our ultimate goal. SIGMA MRL E focuses on customers comfort through improving its environmental performances.

High Performance Highly efficient external gearless traction machine with permanent magnet synchronous motor Precise Control modular structure with real-time control, accurate provision and fast information transfer Stabilized Door System Combination of VVVF door control and PM door leading to higher accuracy with minimal noise Reliable Riding Protection 94 beams of net-crossing light with densely weaved protection plane Duty Load (kg) 250, 320, 450 550, 630,, Rated Speed (m/s) 0.63/1.0 1.0/1.5/1.75 Max. Rise (m) 30 90 Max. Group Control 4 Machine Type PM Gearless Drive VVVF SIGMA MRL E In our modern world, people look for compact, practical but stylish objects. It is no exception for elevators too. In modern contemporary building, machine rooms for each elevator are becoming increasingly cumbersome. Construction requirements change and progress and we, SIGMA, keep our steps together with these changes by continuously improving our technologies and expose ourselves to new innovative challenges. SIGMA MRL E is designed to supply compact and efficient system by employing machine that can be mounted within the hoistway, eliminating the need for a bulky machine room on the roof.

SIGMA MRL E is designed to support overall operation efficiently, taking full account of the different needs of the production, installation and maintenance which lead to handsome cost saving SIGMA MRL E is equipped with highly efficient PMSM gearless machine. Compared with traditional driving system, it can save up to 40% of energy consumption Cost Saving SIGMA MRL E is designed to optimize the layout of hoistway to maximize space utilization of the hoistway thus providing more space for rental Energy Saving SIGMA MRL E Space Saving Time Saving With sophisticated pre-engineered products accompanied by standard processing, SIGMA MRL E can save construction time which will bring a huge benefit to our customers SIGMA MRL E focuses on customers comfort through improving its envronmental performance.

Aesthetics Ceiling COP Indicator C-ES1 VIL-EM1C C-EL1 C-EL2 CBM-EM1C Hairline Handrail HR-04 HR-02 Color P-001 Pearl P-002 Shallow red P-003 light grey P-004 emerald P-005 light green P-006 grey P-007 light blue P-010 blue

$) $) 0WFSIFBE, 0WFSIFBE, Layout OH & Pit Dimension Capacity (kg) Speed (m/s) 250~450 0.63~1.0 Entrance Height (mm) 1.0 550~ Overhead (mm) Pit (mm) Type of Buffer 3 1250 Poly-Urethane Buffer 3 1350 Poly-Urethane Buffer 3950 1500 Oil Buffer 4000 1500 Oil Buffer 2100 1.5 3JTF 3 3JTF 3 1.75 Car and Hoistway Dimension Speed (m/s) 0.63 1JU 4 1JU 4 1.0 1.5 1.75 Persons Load (kg) 6 450 7 550 Opening Type OP (mm) 700 8 630 10 13 3 250 700 4 320 6 450 7 550 8 630 10 13 CO 2S Car size (mm) CW CD Hoistway Size (mm) HW HD 1650 1300 1900 1700 1900* 1 1350 2150 1750 900 1600 2350 1 700 900 1450 1300 900 * In case HW is 1mm, please contact SIGMA 900 1550 1350 1650 1450 1300 1850 1750 1850 1850 1200 1500 1950 1950 2100 1850 2550

Technical Features standard option Features Full Collective Operation Function Introduction All registered car & hall calls will be answered in the sequence by which the elevator cars approach landings. The travel direction of car will be determined by the first registered car or hall call. Top of Car Inspection Inspection operation switches, inspection buttons & emergency stop device are provided at car top. When inspection mode starts, only inspection operation is allowed. Emergency Car Light When the normal lighting power fails, the emergency lighting operates. Separate Car and Hall Call Door Times The time of door retaining open for answering hall call and car call can be adjusted separately. Load Non Stop When a car is loaded to a preset percentage of its rated load, it is considered as full, the car will bypass further hall calls. The hall calls will be registered and will be answered on next trip (single) or by another car (group). Independent Service Overload Warning When elevator stays at independent service, which has been designed to meet special needs of customers, it will no longer answer calls from out of hoistway but only operate, close & open door under manual control. When the car is overloaded, the alarm light and buzzer operate. When overloading is indicated, car door will not close and elevator will not operate. Trip Counter A counter is arranged in elevator control cabinet to count times of elevator operation for the convenience of maintenance. Alarm Bell For passengers to press alarming button in emergency cases to inform outside in time. Light Curtain Light curtain is provided as door closing safety device. Intercom Intercom between surveillance room and machine room and car (including car top/pit) is offered, effective at power failure. Emergency Firemen Operation Emergency Rescue in Controller Parking Operation When fireman switch is on, the system will cancel all calls, drive elevators to fire-fighting floor directly, opens door to release passengers and stop operation. When elevator encounters problem, the emergency rescue in controller is operated to rescue the passengers. Each elevator will have a key switch 'PKS' at a designated landing (e.g., at the lobby). With this feature, a particular car may be commanded by its key switch to the designated landing. Attendant Service The Attendant Operation feature allows semi-automatic operation with manual control. Relevelling Operation Fan Automatic and Light Manual Switch Chime in Car Stopping errors shall be corrected by relevelling. The size of a possible stopping error depends on the type of drive and the accuracy of the position sensors. A manual switch for light power is provided on car operation panel. The fan is controlled by software according to running status of the elevator. A chime installed on car top will ring when the car approaches landing to remind passengers that they have arrived at the destination floor. CCTV Cable CCTV cable from car to machine room is offered. Voice Synthesizer When the car arrives at floor or ready to move, the system will announce about the floor number and running direction by artificial voice. Anti-Nuisance Fire Alarm Home Landing If there is only one passenger in the car and an excessive number of car calls is registered, such nuisance is detected and all car calls will be canceled, requiring registration of a proper number of calls. When fire alarm system in a building is activated, the car will return to appointed floor immediately and send such signal to passengers. Card Reader Passengers with IC card will be permitted to reach appointed floor. BA Interface Elevator Supervisory Panel Elevator Monitor System With PC Automatic Emergency Rescue Device By using a contact the elevator signal such as floor, up-down, fault, over-load, fire alarm etc. will be sent to costumed Building Automation room. Monitor panel will be provided, and the elevator operation situation (running, overload, door opening, fire alarm, fault) will be monitored. To monitor the elevator operation, including floor, running direction, door opening. overload, fire alarm, fault by PC system. When the power fails suddenly, if the elevator has not arrived at the appointed floor, the ARED device will activate the car to reach nearest floor and open the door; if the car has already arrived at the floor, the door will open by ARED.

Please visit our website www.sigmaelevator.com SIGMA constantly endeavors to improve the products therefore the information provided in this catalog is subject to change without prior notice 2012.04 Printed in Korea / Revision No.0