The control system for the MIRI imager Ground Support Equipment

Similar documents
A n hybrid liquid nitrogen system for the cooling. of the ESO O mega C A M detector

RAMSES: THE LHC RADIATION MONITORING SYSTEM FOR THE ENVIRONMENT AND SAFETY

The new generation Teledyne NIR detectors for the SNAP/JDEM mission spectrograph.

Software for Embedded Systems 2011/2012

PRODUCT CATALOGUE. Cape Town 18 Darter Road Blue Water Estate Kommetjie. Gauteng 245 Louis Botha Avenue Orchards Johannesburg

NeXT is a powerful stand-alone application running fully embedded in network cameras to perform an intelligent video surveillance for ATM devices.

securityprobe SNMP-based Environmental and Security Monitoring Solution

LHCb Rich Detectors Control and High Voltage Systems

Active Scanning Beam 2: Controlling Delivery

DEVELOPMENT OF THE TANGO ALARM SYSTEM

User s Manual for ZKIR3 Series IR Day & Night

Technical Specification PILATUS 100K Detector System

Towards a Detector Control System for the ATLAS Pixeldetector

Mass Sensors, Inc. Profile. Applications. Technology Baur Blvd, St. Louis, MO (314)

Fully redundant and customizable alarm, monitoring & Control system

Compact Product Suite Compact HMI 6.0 Overview ABB

The Compact Muon Solenoid Experiment. Conference Report. Mailing address: CMS CERN, CH-1211 GENEVA 23, Switzerland

User s Manual for ZKIR3 Series IR Day & Night

GERDA Slow Control Status. R. Brugnera, A. Garfagnini and D. Zinato. June 9, 2008

Maxline 2 Thermal Imaging Solutions for Manufacturing

SAFEMASTER PRO. The configurable safety system versatile and extendable. Our experience. Your safety.

Temperature Data Logging

ACTIVE INFRARED BARRIER

System Description AutroMaster V Presentation System

Construction of Wireless Fire Alarm System Based on ZigBee Technology

PYROSOFT. Software for DIAS infrared cameras in industry and research & development. Standard and application specific software Overview & Features

JWST FGS SRR. April 7, Ed Nelan TIPS May 20, FGS SRR 7-April

Technical specifications of FT-IR Spectrometer

Research on the Monitor and Control System of Granary Temperature and Humidity Based on ARM

Slow Controls. N. Baltzell 5 th 1 st CLAS12 Experiment Workshop March 28, 2017

BMS Specification. Lonix Ltd.

Home center 2.7 Windows client Installation guide

S ATION EWORK ST BGA R

Wind power Condition Monitoring. Condition Monitoring Systems (CMS) in wind turbines CMS. Authors: Martin Kluge Michael Danitschek

DATA SHEET BENEFITS CURRENT CHALLENGES SSM INFOTECH S X-FORCE AMS - THE IDEAL SOLUTION

A Smart & Integrated Security solution

2008 JINST 3 S The CMS experiment at the CERN LHC THE CERN LARGE HADRON COLLIDER: ACCELERATOR AND EXPERIMENTS.

Security Solutions From The Masters In Electronic Security Systems

Access CONTROL. MANAGEMENT Software

Dew point. Special features: Dew point monitoring DS 400. Technical data DS 400. Technical data FA 510

NU2 Smart Power Supply (SPS) Manual

An FPGA Spectrum Sensing Accelerator for Cognitive Radio

Installation Summary - Dairy Plant

AmpLight Lighting Management System

Break-in Detector and Alarm System

Product Datasheet MM8000 MP3.10 Management Station

Universal modular MWD platform adapted for your needs

Application of OPC in the Intelligent Building System Integration

MK8000 MP1.20 OPC Server for subsystems

opti-visor ultra-efficient chiller plant automation Typical specification

Application of Control System Studio for the NOνA Detector Control System.

YOUR PARTNER IN FIRE & GAS DETECTION

Remote Helium Cooling Loops for Laboratory Applications

Dew point set DS 400

Automobile Security System Based on Face Recognition Structure Using GSM Network

P2000 and Metasys System Integration

Introduction. Phil Spicer. Manager Railway Electronic Systems

Variable Temperature Options for Optical Experiments

PSM CONTROL & MANAGEMENT PRODUCT CATALOGUE. GAMATRONIC, A SolarEdge Division. 17 Hartom Street, Jerusalem , Israel

Smart Sensor in Wide Area Network Environment How can sensors improve your safety? Tadeusz Pietraszek

Vykon. Security. Integrated Access Control. Web enabled security management built on the Niagara Framework

Technical Specification and Operating Procedure PILATUS 300K

UD-VMS510i. Surveillance Management Center

D-Link Central Management System

metro B6012 VIBRATIONS SIMPLIFIED... Product brochure Easiest portable vibration analyzer and balancer TECHNOLOGIES PVT. LTD.

Protect your investment with Safety Manager

Flexibility. adjusted to specific needs of a client.

Tixi Alarm Modem Aluminum Housing Analog / ISDN / ISDN & Fax / GSM

NGC ESO s New General Detector Controller

GasGard 100 Control System

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION IBAS LIGHTING CONTROL

EC-BOS-602/616 AX Security

Dräger VVP 1000 System Components

THE ALICE EXPERIMENT CONTROL SYSTEM

Recent Improvements in Process GC Instrumentation

ANNEX A.1 TECHNICAL SPECIFICATIONS Negotiated Procedure FRA Provision of Security Supplies and Installations

Compact HMI Overview

Expected needs in Electronics for the CERN Experiments. 5 October 2015

Optical Detector Systems

Spectrometer Systems Overview

How to Select an Industrial PC with I/O for a Wide Temperature Application

Coal Pile Fire Monitoring System

First results and developments of the multi-cell SDD for Elettra and SESAME XAFS beam lines

ARCHITECTURAL AND ENGINEERING SPECIFICATION

PROCESS CONTROL COURSES

Specifications Wavelength Range: 190 nm to 800 nm continuous

REMUS: The new CERN Radiation and Environment Monitoring Unified Supervision

CODAC Core System 5.4 CS-Studio Release Notes

BGA Rework Station Pro-660

General Surveillance Management Centre. DSS is a flexible, scalable, high reliable and powerful central management system.

Homework 8: Patent Liability Analysis

Design specifications and test of the HMPID s control system prototype in the ALICE experiment

HikCentral Web Client. User Manual

Facility Explorer Asset Protection by Yorkland Controls Ltd. Fr

Team Rescue X: Autonomous Firefighting Robot

Fire and Gas Monitoring Panel ST7-HV

Use of the application program. Functional description. instabus EIB Application program description. October CO Touch-Manager wave

CRUSH: Cognitive Radio Universal Software Hardware

Safety Instrumented Fire & Gas Systems

Implementing Efficient Split-Radix FFTs in FPGAs

Transcription:

10th ILEPCS Int. Conf. on Accelerator & Large Expt. Physics Control Systems. Geneva, 10-14 Oct 2005, PO1.040-6 (2005) The control system for the MIRI imager Ground Support Equipment F. Gougnaud, Ph. De Antoni, Y. Lussignol, D. Arranger, G. Durand, D. Eppellé CEA-Saclay/DAPNIA/SIS ABSTRACT The Mid Infra Red Instrument (MIRI) is one of three instruments to be built for the spatial telescope James Webb (JWST). Our division CEA Saclay/Dapnia is in charge of designing and delivering the imager of MIRI and developing its test bench called the Ground Support Equipment (GSE). This GSE is composed of a warm telescope simulator, a cryostat and an infrared detector. This paper will describe the control system for the GSE. This control system is composed of a fast acquisition system, a slow control and PLC s for the cryostat including safety management. For the fast acquisition and images visualisation, the ESO data acquisition software IRACE (InfraRed Array Control Electronics) is used. The originality of this project lies in the simultaneous use of IRACE, of EPICS for the slow control and of the automatisms system based on the WoldFIP Fieldbus network and its WEB supervision. These three software subsystems will communicate and the supervision will be centralized on two redhat Linux PCs. All the boards are purely industrial. This test bench should be put in operation at the beginning of 2006. INTRODUCTION The James Web Space Telescope (JWST) is the successor of Hubble in the infrared. It will be launched in 2013. Its science goals are the star formation and the evolution of galaxies with large redshift, the formation of planets and dust clouds. The Mid Infra Red Instrument (MIRI) is a spectrometer and an imager. Our division, Dapnia located at CEA Saclay, is in charge of the design and completion of the optomechanical part of the imager called MIRIM and of its test bench called the Ground Support Equipment (GSE). This GSE consists of a warm telescope simulator and of a cryostat to cool the imager down to its operating temperature. The cryostat contains a model of the imager, identical to the flight model. The warm telescope simulator is composed of several optical components to control (a hexapod, a point source, an extended source, a monochromator and a shutter). The imager contains a Filter Wheel with 18 positions and a 1024x1024 pixels InfraRed detector. ARCHITECTURE OF THE CONTROL SYSTEM We focus all our software development on the ESO (European Southern Observatory) and EPICS (Experimental Physics Industrial Control Systems) communities software. From ESO, we use the IRACE software dedicated to the fast acquisition of the IR detector. For the slow control of the IR detector and optical devices, EPICS is used. The IR detector needs a slow control for the polarisation and clocks signals voltages. We will base the cryostat control supervision on the software developed in our industrial control and data processing Lab. The software IRACE, the program positioning the Filter Wheel and some cryostat temperatures readout need to communicate with EPICS. Furthermore, EPICS Channel Access software () running on Linux and Windows is used.

10th ILEPCS 2005; F. Gougnaud, Ph. De Antoni, Y. Lussignol, D. Arranger, G. Durand, D. Eppellé et al.... 2 of 6 EPICS Channel Access Telescope simulator Hexapod Point Source Monochromator Shutter Peltier EPICS/vxWorks VME Ethernet Supervision Station Linux PC Infrared light Cryostat EPICS + ANIBUS/FBI WEB access MIRIM Motor Filter Wheel control XP PC Visual C++ MPIA Heidelberg Acquisition Control Station Linux PC IR Detector Actioners vacuum, nitrogen,liquid helium Temperature sensors Heaters IRACE acquisition industrial Linux PC Ethernet 1 Gigabit modified IRACE PLC WorldFIP WEB Server Anibus/FBI industrial PC XPe Figure 1: Control system architecture synoptic

10th ILEPCS 2005; F. Gougnaud, Ph. De Antoni, Y. Lussignol, D. Arranger, G. Durand, D. Eppellé et al.... 3 of 6 COTS BOARDS FOR FAST ACQUISITION IR DETECTOR Our Lab was in charge from 1998 to 2004 of the control system of the VISIR instrument (VLT Imager and Spectrometrer for mid InfraRed) for the Very Large Telescope at Paranal. We had to use the controller IRACE. This controller consists of a software package and electronic boards designed by ESO. It was decided to re-use IRACE for the MIRI test bench. ESO couldn t provide their electronic boards. Consequently, we had to choose convenient COTS cards to replace the ESO s boards but less specialized. A frame of the detector (1024 x 1024 pixels) is read per block of pixels. A frame is the full readout of the detector. The needs to read this detector are: a sampling rate comprised between 0.5 and 1 Mega samples per second with 16-bit resolution, 24 signals for clocks. We have selected SPECTRUM products: digital I/O MI7011 boards with embedded memory of 512 Mbytes, ADC MI4541 boards with 16-bit ADC resolution and a sampling rate up to 1 MHz and 128 Mbytes of embedded memory. Two MI7011 boards are needed. The first is dedicated to the readout of the detector and sends a full sequence of fast TTL signals to the IR array for a complete frame readout. This board generates the clock for the other MI7011 dedicated to the experiment. This second MI7011 generates the slow synchronous signals, for example the shutter signal to open/close the shutter and the Frame Trigger signal to start the digitized acquisition of a frame. The MI4541 board achieves the acquisition itself in its local memory from the IR array. It uses the Frame Trigger signal and the Acquisition Clock signal, coming from MI7011 boards, as external trigger and clock. The possibility to use up to 4 MI4541 boards provides flexibility for different IR detectors. In this case, the first MI4541 board supports a starhub that synchronizes the different MI4541 boards. Figure 2: COTS acquisition boards

10th ILEPCS 2005; F. Gougnaud, Ph. De Antoni, Y. Lussignol, D. Arranger, G. Durand, D. Eppellé et al.... 4 of 6 PORT OF ESO IRACE SOFTWARE IRACE software [1] splits tasks between the instrument workstation and the acquisition workstation close to the hardware. For our test bench, this software architecture was globally saved between the acquisition workstation and the acquisition control workstation. The port for MIRI includes three points: the Detector Control System server task communicating with the EPICS Control Database for the detector voltages (biases and low/high clock levels), the configuration and programming of the MI7011 boards used as Sequencer, the Data Acquisition from the MI4541 boards. Figure 3: IRACE software architecture THE IR DETECTOR SLOW CONTROL To control biases, low/high clock levels and temperatures we use EPICS on a Linux Red Hat Enterprise 4 PC for the user interface and a VME with a Motorola CPU MVME2434 equipped with vxworks. Due to the deadline to provide this GSE, we chose our traditional solutions relying on ADAS VME boards to save time for the developments around the new devices. THE TELESCOPE SIMULATOR SLOW CONTROL The telescope simulator comprises different devices: a point source, an extended source provided by a Peltier, a monochromator and a hexapod for alignment. These devices are all interfaced by RS232 serial lines and their control will rely on streamdevice2 EPICS software [3]. It has a device driver for byte stream oriented I/O. This support runs on vxworks as well as on Linux. Presently, only the Cornerstone motorized monochromator is present in the Lab and the tests are in progress. The second device to control will be a 6-axis positioning Hexapod that provides servo-controlled motion in 3 translation and 3 rotational axes.

10th ILEPCS 2005; F. Gougnaud, Ph. De Antoni, Y. Lussignol, D. Arranger, G. Durand, D. Eppellé et al.... 5 of 6 COMMUNITION WITH THE MPIA FILTER WHEEL COMMAND CONTROL The cryo-mechanism of the Filter Wheel located in the MIRIM Model is the responsibility of the Max Planck Institute of Astronomy (MPIA) in Heidelberg. The motions of this wheel need very complex algorithms that will be provided in the VISUAL C++ 6.0 environment. Meanwhile, our Linux oriented control system needs to communicate with the Filter Wheel. For instance, before starting an IR detector acquisition, the 18 positions Filter Wheel has to be moved to a position in imaging or coronographic mode. Therefore, we have defined a software interface with MPIA to get the position of the wheel, to move it to a desired position, to get the status of the movement and to get temperature from a sensor. Once more, this communication is based on Channel Access and this time, on Windows. The release EPICS R3.14.7 was easily built on Windows XP using the Linux like environment Windows cygwin and the compiler and linker cl from VISUAL C++.NET 7.0. CRYOSTAT CONTROL SYSTEM The cryostat subsystem requires a high reliability and safety level. Thus it has its own dedicated control system, the standard one used in Dapnia cryogenics installations [4] [5]. The architecture is based on real-time fieldbus WorldFIP, a PLC and an industrial PC. The PLC manages the process through temperature sensors, heaters and other devices aimed to vacuum, helium or nitrogen. Safety is implemented at this level. A bus arbitrator running on its FIP interface guarantees data exchange determinism. The XPe industrial PC runs the home made Anibus-FBI supervision system. Spying the fieldbus it handles acquisition and also provides alarms and historic features. It hosts a WEB server and the client side supervision, implemented as a Java applet, is available remotely on most platforms without any particular installation. Furthermore, real-time process data are exported to the EPICS system through Channel Access. USER INTERFACES To start the EPICS tasks (displays, trend curves, archiving, logging errors and IOC) the user interface is based on the free RAD Glade (interface builder for GNOME). This development was also carried out jointly for the control system of the Superconducting Magnet of the COMPASS Experiment [6]. From this Red Hat Linux PC dedicated to the general supervision, the operator will also be able to control the cryostat from our Linux Internet Browser. On the Red Hat Linux PC, dedicated to the IR detector acquisition control, the Broker for Observation Blocks (BOB) will be the main user interface with the bench. BOB is a tool provided with the VLT software. Observation Blocks form the fundamental underpinning for the planned usage of the bench control system with a series of expositions. BOB executes templates that are sequencer scripts for tcl. The observing template is a pre-defined sequence of operations involving any combinations of actions with IR detector or Filter Wheel or light sources and that are essentially communication with EPICS variables or IRACE commands. CONCLUSION The IRACE software port is achieved and the tests on the SPECTRUM boards are in progress. Our choice of Red Hat Enterprise Linux was judicious because it provides a stable and reliable environment for developments with an efficient on-line support. Blending solutions based on EPICS, ESO IRACE and the Dapnia standard cryogenics supervision will permit us to deliver the control system for this MIRIM Ground Support Equipment in May 2006.

10th ILEPCS 2005; F. Gougnaud, Ph. De Antoni, Y. Lussignol, D. Arranger, G. Durand, D. Eppellé et al.... 6 of 6 ACKNOWLEDGEMENTS The author wishes to acknowledge Ph. Beauvais to build the electronic rack, A. Donati in charge with P. Bargueden of the safety of the cryostat and its rack. REFERENCES [1]IRACE the ESO Controller for Infrared Arrays www.eso.org/projects/iridt/irace [2]Y. Lussignol, JWST MIRIM-OB GSE Système de contrôle du détecteur MIRI-DD-00156-CEA [3]D. Zimoch, Stream Device 2 http://epics.web.psi.ch/software/streamdevice/ [4] C. Walter, Les technologies Internet dans les systèmes de contrôle commande Jautomatise mai 2003 [5] C. Walter, Supervision Web avec Java, c est possible Jautomatise septembre 2004 [6] J.F. Gournay, Quench Data Acquisition and Slow Control for the Superconducting Magnet of the COMPASS Experiment ILEPCS 05