CE marking of fire-resistant doors the right way!

Similar documents
EN CE instead of approval Opportunities for manufacturers and trading to enter new markets in Europe

Guidance Note No 21/1. CE Marking Windows and doorsets to BS EN 16034

Technical Bulletin CE marking: from 1st July 2013

PRESS RELEASE

Centexbel. General certification regulations. Construction products

CE Marking for Fire Resistant doors. The future EN Agustín Garzón Cabrerizo Technical Director Fire Resistance Lab.

Implementation of the Construction Products Regulation (CPR) in harmonized standards - Template for Annex ZA -

Declaration of Conformity Declaration of Performance Notes

best practice guide Pedestrian doorsets Fire resisting and/or smoke control characteristics - to

Assessment Report Construction Product Regulation* * CPR - REGULATION (EU) No 305/2011

Implementation of the Construction Products Regulation (CPR) in harmonized standards - Template for Annex ZA -

CE marking of industrial doors under the CPR Michael Skelding, Secretary and General Manager Door and Hardware Federation

1. Terms defined in the Construction Products Regulation (CPR)

Cylinder Mortice Dead lock Lockcase(mm) A=87 Backset (mm) B=55. Follower (mm) 8 Latch Bolt

F O C U S D O O R C L O S E R S

DID YOU GET USED TO THE NEW CPR? HERE S A QUICK REVIEW!

Guidance Note No 19/1. CE Marking windows and doorsets

Guidance from the Group of Notified Bodies for the Construction Products Regulation 305/2011/EU

Kiwa Regulations for Certification in accordance with the CPR

Frequently Asked Questions on the Construction Products Regulation (CPR) - Enterprise and Industry

Construction Products Directive

Construction Products Directive

The New Generationn of Firedoors

Guideline Construction Products Regulation (EU) 305/20122

CONSTRUCTION PRODUCTS REGULATION 2011 DECLARATION OF PERFORMANCE

CONSTRUCTION PRODUCTS REGULATION 2011 DECLARATION OF PERFORMANCE

Europacable FAQ on CPR Status: 26/01/17

European Technical Approval ETA-08/0035 This ETA replaces ETA-08/0035 with validity from till

TFI Report Classification

Üntel is ready for CPR

Window and Door Standards for Performance and Security. Russell Day Senior Technical Officer Glass and Glazing Federation

Classification Report Reaction to fire of building elements DIN EN :2007. Class E

Your Key to achieving C.E Marking Compliance

Regulation 574_2014: Annex III CPR. and. Regulation 568_2014: Annex V CPR

Regulation (EU) No 305/2011 laying down harmonised conditions for the marketing of construction products (EU CPR)

YOUR GUIDE TO UNDERSTANDING CPR

The New EU-Regulation on Construction Products

Implementing the Construction Products Regulation (EU) 305/2011

Co-ordination of the Group of Notified Bodies for the Construction Products /Regulation 305/2011/EU

CERTIFICATE. Conformity of the Factory Production Control CPR TÜVRh

ETICS and the EU Internal Market The European framework. G. Katsarakis European Commission, DG GROWTH Unit C-1: Clean technologies and products

The Danish Energy Authority to carry out inspections in June and July 2012

DECLARATION OF PERFORMANCE

PART 3-O REQUIREMENTS FOR SPRINKLER SYSTEMS MAINTENANCE AND SUPERVISION. 3-O Introduction O.1 Scope of Maintenance and Supervision...

Declaration of Performance and CE marking of windows and external pedestrian doorsets according to the CPR

CE marking of noise barriers and foundations

Contents EN :2006+A2:2016 (E)

SUPPLEMENTARY REGULATIONS SPECIFIC TO CERTIFICATION OF PERSONAL PROTECTIVE EQUIPMENT (PPE)

Additional reaction to fire classification report No H

See product BS EN :2010

New Requirements for Placing of Medical Devices on the Market: Conformity Assessment to the Technical Regulations

Guidance on Declaration of Performance and CE marking of windows and external pedestrian doorsets according to the CPR

CPR, CE-marking of construction products 1

DECLARATION OF PERFORMANCE

CONSTRUCTION PRODUCTS REGULATION MOLEX CES COPPER AND FIBRE CABLE

Declaration of Performance

Guidance Note on the Construction Products Regulation

Procedure for the Approval of New Fire Detection and Alarm Technologies

The Danish Energy Agency will carry out inspections in June 2013

Reference F-IAB-012 Page Page 1 of 6 Revision 2. Please complete all sections and submit electronically to

TFI Report Classification

DECLARATION OF PERFORMANCE

Circuit Breakers JANUARY The electronic pdf version of this document found through is the officially binding version

CO-ORDINATION OF NOTIFIED BODIES PPE Regulation 2016/425 RECOMMENDATION FOR USE

COMMISSION DELEGATED REGULATION (EU) /... of

COMMISSION DELEGATED REGULATION (EU)

SD119 Range of Conventional Smoke and Smoke/Heat Detectors (refer to attached appendix for details and conditions)

COMMISSION DELEGATED REGULATION (EU) /... of XXX

COMMISSION DELEGATED REGULATION (EU) /... of

Electromagnetic Locking Devices Performance Requirements

Introduction. Declaration of performance (DoP) CE marking

Best Practice Guide. Windows and Doors. Single-axis hinges to BS EN

DECLARATION OF PERFORMANCE

White paper. Construction Product Regulations* by Multimedia Connect. Which cables are concerned by these new regulations?

GNB-CPR Position Paper: Issuance of certificates under CPR

Georgios Katsarakis European Commission

Belcom Cable excellence engineered through quality. CPR Construction Products Regulation

Mechanically operated locks and locking plates

English Version. This draft European Standard is submitted to CEN members for enquiry. It has been drawn up by the Technical Committee CEN/TC 226.

Chief Operating Officer Giampiero Belcredi

ECB S Recommendation for Service, Repair and Modification Operations on ECB S Certified Secure Storage Units, Data Cabinets and Data Rooms

Reporting Changes to your Notified Body

FUNCTIONAL SAFETY OF ELECTRICAL INSTALLATIONS IN INDUSTRIAL PLANTS BY OTTO WALCH

Sýnishorn Glass in building - Insulating glass units - Part 5: Evaluation of conformity

Construction Products Regulation (CPR)

Domestic Garage Doors

MARKING EC Directive 97/23 PED (Pressure Equipment Directive)

The effects on the UK Fire Industry. Paul Pope Eng.Tech AIFireE

Council Directive 93/68/EEC of 22 July 1993 amending Directives

BUSINESS PLAN CEN/TC 164 WATER SUPPLY EXECUTIVE SUMMARY

Notified Body No.: 0098

best practice guide BS EN 14846: 2008 Electromechanically operated locks & striking plates to in association with

Shipboard incinerators with capacities up to 4000 kw

Specification for Road Works Series Introduction

Declaration of Performance

For structural use in all types of construction works according to EN

BRL-K21030/02 5 August Certification of Alarm Communication. Certification Alarm Transmission Systems (ATS) Alarm Transmission Systems

This European technical approval

VdS Guidelines for the Certification of Monitoring and Alarm Receiving Centres according to DIN EN 50518

Implementation of Harmonized Standards - A Member State Perspective. Norway

Transcription:

Page 1 of 5 ift Rosenheim CE marking of fire-resistant doors the right way! Surveillance and certification of fire safety products 1 Introduction The product standard for doors, gates and windows with fire protection and / or smoke control properties, DIN EN 16034 is raring to go: It will control many new things both for system providers and also for manufacturers and will become noticeable in day-to-day life. With the introduction of the product standard, preparation of a declaration of performance and the CE marking will first now be possible even for fire-resistant doorsets and then become mandatory. The system provider and manufacturer will have to say goodbye to the system so far of approvals issued by supervisory construction authorities. There will also be changes on the part of the institute and approval bodies. A new body is appearing on the horizon with far-reaching duties the Notified Product Certification Body (Notifizierte Produktzertifizierungsstelle, NPZ). The activities of this body stretch from test specimen planning to testing and preparation of the verifications right up to surveillance and certification of the manufacturers. The testing of the fire-resistant doorsets itself is done by a testing body that need not be the same as the NPZ. However, the NPZ retains the responsibility for the entire procedure. The areas of surveillance / certification and labelling of fire-resistant doorsets are described in detail in the following. 2 Basic Principles So-called surveillance bases will have to be created for the surveillance and certification of the manufacturers. This documentation describes the fire-resistant doorsets and they contain the specifications for their manufacture. This documentation forms the basis of the activity for the NPZ and the evaluation of the surveillance results. Essentially, the following documents form the basis of this surveillance: the classification report the EXAP report (extended area of application) system documentation for the manufacture of fire-resistant doors

Page 2 of 5 The classification report In this report, the fire-resistant doorsets are classified on the basis of tests conducted, the components tests are described and the system limits are specified. This represents the direct area of application. Substitution of components or deviations from the designs described, parameters of construction products are not possible or possible only within a narrow framework. The EXAP report (extended field of application) In this document, based on other verifications, expert opinions and / or assessments, clearance is issued for the use of alternative components, profiles or dimensions for the system of the fire-resistant doorsets. This represents the extended area of application. System documentation As always, this documentation also contains all information that is necessary to manufacture the fire-resistant doorsets (manufacturing drawings, tolerances etc.). Fig. 1 Technical documentation

Page 3 of 5 3 Certification and surveillance 3.1 The contract At the beginning of the entire procedure, a surveillance and certification agreement is concluded between the manufacturer and the Notified Product Certification Body. The subject matter is defined as the surveillance and certification (= fire-resistant door system) in this agreement, and the costs of surveillance / certification are mutually agreed to and the "rules of the game" are laid down. No agreement can be concluded without a valid classification report. 3.2 Initial inspection The Notified Product Certification Body conducts an audit at the manufacturer's factory. In the course of these audits, the basis for surveillance is mutually agreed with the manufacturer and the manufacture of the fire-resistant doors is monitored. This is why ongoing production is necessary at this point in time. Moreover, the factory production control (FPC) must be set up, whose contents and documentation is the subject matter of this visit. The FPC is identified as a significant task of the manufacturer in the product standard (Point 6.3). The purpose of the FPC is to ensure and document design and manufacturing conformity of the fire-resistant doorsets. This is why the FPC system cannot begin only in the production, but must already be in use during the design and planning phase in order to avoid errors or identify them at the beginning of the process. Moreover, dealing with non-conforming products must be specified in this system and the classification / labelling of the fire-resistant doorsets must be specified. What must not be overlooked is that the qualification of the personnel, maintenance and service of machines and systems as well as the surveillance of test equipment must also be an integral part of the FPC system. 3.3 Certification After the initial inspection, the NPZ evaluates the results of the audit and whether the basis for surveillance is complete and adequate in order to manufacture conformant fireresistant doorsets. The manufacturer also has the option of eliminating non-conformances that have been identified by corrective measures. These measures must be proven to the NPZ with the help of suitable verifications. If there is a favourable overall rating (= conformity rating) by the NPZ, the "Certificate for certifying the constancy of performance" is issued by the NPZ with a validity of three years for the manufacturer. From this point in time, the manufacturer may provide his fireresistant doors with a declaration of performance and the CE mark and market them.

Page 4 of 5 4 Continuous surveillance After the certification, the continuous surveillance of the manufacturer begins. An audit is conducted in the manufacturing factory every year in accordance with the specifications from the product standard. In case of favourable results, the "Certificate for certifying the constancy of performance" is maintained or renewed after three years. Apart from auditing the production and the FPC, modifications in the manufacturing process or the advanced development of components or constructions in the basis of surveillance, are an important constituent of the surveillance. 5 Declaration of performance and CE marking 5.1 Declaration of performance An example of the declaration of performance (DoP) is given in the product standard (Annex ZA, clause 2.2). You can get detailed information and a sample from the Construction Products Regulation (CPR). The contents of the DoP are binding for the manufacturer. In the DoP, all significant properties of the fire-resistant doorsets (= mandated properties, refer to the product standard Annex ZA.1, Table ZA.1) must be listed. Moreover, at least one property must be classified. Properties, for which the manufacturer does not provide any information, must be marked with "npd" (no performance declared). 5.2 CE Marking With respect to the contents of the CE mark, the specifications are also given in the product standard (Annex ZA.3). The "npd" option should not be used here. Only those properties should be listed for which the manufacturer undertakes classification. The information of the target market required by building law must be specified as a minimum. Moreover, permanent and visible marking must be affixed on the fire-resistant doors. The letters "CE" according to the marking ordinance and the number of the NPZ must be specified (example for the NPZ ift: "CE 0757 ). A label must be affixed on the packaging of the fire-resistant door. This labelling must contain the following information: Manufacturer (name, contact information for the customers) Product type or designation Typecasting the product classification of the fire resistance and / or smoke control classification and / or class of self-closure

Page 5 of 5 Fig. 2 Example: CE marking with two valid product standards 5.3 The procedure of the declaration of performance and the CE marking in the market The declaration of performance must be provided to the customer directly. It may be implemented as paper, in electronic form via email or on call e.g. on the website of the manufacturer. The CE mark must be affixed on the fire-resistant doorset or its packaging or it must be available in the documents accompanying the product. A link must be established between the respective DoP and the CE marking by a unique code or numbering that enables the customer to identify and assign both documents. 6 Conclusion Experience with other product standards has shown that the implementation of the regulations and administrative requirements associated with it need time, but that it is feasible with systematic preparation for all those involved. Hence, it makes sense to deal with the product standard and the associated changes at this juncture and to initiate the planning for implementation. The ift Rosenheim is at your disposal as a notified and product certification body with experience and appropriate solutions. Thus, in the field of fire-resistant doorsets nothing must be "on fire" not even after the introduction of DIN EN 16034. Literature [1] DIN EN 16034:2014-12 Pedestrian doorsets, industrial, commercial, garage doors and openable windows -Product standard, performance characteristics - Fire resisting and/or smoke control characteristics EN 16034:2014-12, Beuth Verlag GmbH, Berlin