Hands-On Fiber Optic ISP / OSP Combo-Tech Splicing, Termination & Testing

Similar documents
Hands-On Fiber Optics ISP/OSP - Advanced Combo- Tech

Fiber Optic and CAT 5, 6, 7 and 8 Installer Premise Cabling

Fiber Optics for Todays Industry Applications

Hands-On CAT 5/6 & Fiber Optic Installer

Basic Professional Fiber Optic Installation

Certified Fibre Optic Specialist - Testing

Qualified Partner Programme QPP. Field-termination of FO connectors Felice Guarna

Fibre Optic Basics FIA Summer Seminar 2014

Advancing Fiber Optic Connectivity

FTTH NETWORK TESTING: REAL APPLICATIONS USING THE OLTS METHOD

Special Provision No. 683S28 December 2017

Ensuring Cabling Performance in the Customer-Owned Outside Plant

OFS IV Optical Fibre System

2016 CDM Smith All Rights Reserved July 2016 SECTION FIBER OPTIC DATA NETWORK

Ensuring Cabling Performance in the Customer-Owned Outside Plant. Keith Foord Product Manager Greenlee Communications

FIBRE OPTIC COMMUNICATION CABLES, IN DUCTS - Item No. FIBRE OPTIC COMMUNICATION CABLES, IN DUCTS (TEMPORARY) - Item No.

HELKAMA. Optical Fibre Cables

A. General: Horizontal and backbone cabling shall be verified in accordance with ANSI/TIA/EIA-568-C and the addendum for fiber optic testing.

Fiber Optic Products Catalog

RLH Industries, Inc. Cleaning and Testing Fiber Optic Cable. Reference Guide MD A 0507

Sterlite Tech Academy Creating Smarter Network Professionals

GR-326-CORE Singlemode Optical Connectors and Jumper Assemblies

OPTICAL TIME-DOMAIN REFLECTOMETER

Product Catalogue. External Management

STANDARD TEST PROCEDURE PRE-TEST QUALITY OF OPTIC FIBRE CABLE ON DRUMS TYPE OF CABLE :

STATE OF NEW JERSEY DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY SPECIFICATIONS FOR FUSION SPLICE AND SPLICE ENCLOSURE FIBER OPTIC CABLE

STANDARD CONFORMANCE

Field Testing and Troubleshooting of PON LAN Networks per IEC Jim Davis Regional Marketing Engineer Fluke Networks

Reflectance, The Hidden Danger That Increases Bit Error Rates in Your Fiber Networks Denver, May 22nd, 2010

Sumitomo Fiber Specification SE-6** Non-Zero Dispersion Shifted Single-Mode Fiber. PureGuide SM Optical Fiber, TIA Type IVd. Issued: November 2003

Optical Time Domain Reflectometry (OTDR)

Optical Return Loss Measurement by Gregory Lietaert, Product Manager

Field Test Procedure for Optical Fibre Link Measurements

Fibre Characterisation and FTTx New challenges

Savitri Telecom Services

Sumitomo Fiber Specification SE-9** Non-Zero Dispersion Shifted (NZDF) Zero Water Peak Large Effective Area Single Mode Fiber

Optical Fibres ELEC8350

STANDARD FOR INDOOR-OUTDOOR OPTICAL FIBER CABLE

MTTplus Modular Test Platform

4120 Fire Alarm Network Reference

Fibre optic media options and trends

Qualification Test Report LC Duplex Adapter For LC Cutouts

Broadband System - H

SECTION COMMUNICATIONS FIBER CABINETS, ADAPTERS AND CONNECTORS

Qualification Test Report LightCrimp* Plus Singlemode and Multimode LC Connector (Field Installable)

Core Alignment All In One Fusion Splicer

SECTION TESTING OF FIBER OPTIC CABLES

M700-Series Multifunction OTDR

ITU-T L.12. Optical fibre joints SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT

Fibre Solutions for Harsh Environments

OWL. Laser OWL Series. Operations Guide. Singlemode Light Sources. Optical Wavelength Laboratories. Date: October 1, 2015

The Fiber SenSys Perimeter Intrusion Detection System From JM Fiber Optics!

A world of fiber Product overview

Noyes OFL 250B Specs Provided by

Connections You Can Count On.

Fibre (TIA) Field Test Specification

OPTICAL FIBER JOINTS & CONNECTIONS

Kingfisher KI-3800 Light Source. Inexpensive handheld source for testing and commissioning optical fibre networks. Compact and rugged,

LAB REPORT SUBMISSION COVER PAGE ETN4106 OPTOELECTRONICS AND OPTICAL COMMUNICATIONS

Fiber Optic Patch Cord and Pigtails

OTDR II. Tier-2 Optical Time Domain Reflectometer for Multimode and Single-mode Fiber Cabling

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

FACULTY OF ENGINEERING LAB SHEET OPTICAL COMMUNICATION SYSTEMS EOP4066 TRIMESTER 1 (2013/2014)

INTERNATIONAL TELECOMMUNICATION UNION SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT

The Optical Time Domain Reflectometry and the Fusion Splicer Laboratory exercise

Fujikura-70S Single Fibre Fusion Splicer

STANDARD FOR INDOOR-OUTDOOR OPTICAL FIBER CABLE

M310 Enterprise OTDR. Designed for Enterprise Network Testing, Troubleshooting and Documentation. or (800) , (603)

Propagation loss in optical fibers (01/29/2016)

Attenuators. Fiber Optic Products Catalog. Singlemode Build Out Attenuators. Product Facts. Applications. Customizable Features. Available Collateral

Link loss measurement uncertainties: OTDR vs. light source power meter By EXFO s Systems Engineering and Research Team

20 20 MARKET SOLUTIONS INSPIRATION INNOVATION INTEGRATION. Industrial Solutions

Fibre Specification Standards

OTDR - FHO5000-xxx. Optical Time Domain Reflectometer

M310 Enterprise OTDR. Designed for Enterprise Network Testing, Troubleshooting and Documentation. or (800) , (603)

Fibre Optic Cable. Catalogue.

Figure 1 - Parts of a Fiber Optic Connector

HIGH POWER FIBER OPTIC PATCHCORDS

Fiber Tes)ng 101 Essen)als Every Network Analyst Needs to Know. David S(llwell BCNET Oscar Rondon BCNET Gwenn Amice - EXFO

FLX380-30x FlexTester3 OTDR

INSPIRATION INNOVATION INTEGRATION. Termination and Test Solutions

FiberExpress Solutions

palmotdr Series Handheld OTDR

ITU-T L.404. Field mountable single-mode optical fibre connectors

Dome Fiber Optic Closure SC-221

M310 Data Center OTDR

PC474 Lab Manual Wilfrid Laurier University 1

AV6416 OTDR. Product Overview: Main Features:

FIBER OPTIC TESTING JIM HAYES OVERVIEW

Data sheet OpDAT breakout cable 12x1 OM4 - bend insensitive, class Dca s1 d1 a1

Erbium-Doped Fiber Amplifier (EDFA) - MW Series

SECTION COMMUNICATIONS OPTICAL FIBER BACKBONE CABLING

Long-Range Displacement Sensor Based on SMS Fiber Structure and OTDR

TROUBLESHOOTING AT THE SPEED OF LIGHT EMBEDDED OTDR FOR OPERATIONAL EXCELLENCE IN PASSIVE OPTICAL NETWORKS

Jan07 Rev B

Data sheet OpDAT mini breakout cable 24x1 OM4 - bend insensitive

Fiber Optic Connector Cleaning and Inspection Kit Instructions

AE3100A~M Series 2-and 4-Wavelength Handheld OTDR

Integrated optical fiber shape senor modules based on twisted multicore fiber grating arrays

CITY OF AUSTIN ARTERIAL MANAGEMENT DIVISION SPECIFICATIONS FOR THE INSTALLATION AND MAINTENANCE OF SINGLE MODE FIBER OPTIC CABLE

Transcription:

Hands-On Splicing, Termination & Testing BICSI CECs This course has been approved for CEC credits by BICSI. Please read below for a breakdown of the credits that we offer for this course. For more information regarding BICSI please visit our website. RCDD: 21 OSP: 21 Inst: 21 Tech: 21 Cert. Trainer: 21 Course Description This Hands-On 3-day course has been customized to provide technicians with a practical understanding of fiber optic theory and fiber applications in (ISP)Local Area Network, Security and Closed Circuit TV systems and more in-depth Hands-On focus on a wider array of (OSP) Fiber Optic systems and components, installation, splicing, testing and maintenance techniques... A Fiber Optic Installer has a general understanding of optical fiber installation, connectorization, splicing, and testing, is familiar with optical fiber, connector, and splice performance characteristics described in TIA/EIA-568B, ITU-T G.671, ITU-T G.652 and Telcordia GR-326 A Fiber Optic Installer can perform connector endface evaluation as described in TIA/EIA-455-57B, is proficient in optical loss testing as described in TIA/EIA-526-14A, and understands the installation requirements described in articles 770 and 250 of the National Electrical Code. A Fiber Optic Installer is proficient at the installation of connectors on various types fiber of optic cables using various types of epoxies, and can perform mechanical and fusion splicing and more... This course is Accredited by the International Certification Accreditation Council (ICAC) Optional ETA Exams Available (FOI, FOT, FOT-OSP) Exam (Can be administered at the training location upon request as part of the course, fees apply.) Type of Certification Stand-Alone Renewal / Maintenance Required Certification Term 4 Yrs Hands-On Required Yes Students Will Learn Page: 1 of 7

The History Of Fiber Optics & Evolution Of Fiber Systems. Fiber Manufacturing Methods. Fiber Optic Theory And Waveguide Functions. Singlemode (OSP) And Multimode (ISP) Fiber Types. The Causes Of Attenuation, Optical Reflection And Refraction. Optical Dispersion Characteristics And Pulse Spreading Issues. Loose Tube And Unitube Style Trunk Cables Distribution And Feeder Cables. Fusion Splicer Applications And Fiber Alignment Systems Mechanical Splicing Uses And Applications Optical Connector Styles And Applications Back Reflection Issues And Angled Physical Contact Connectors Patch Panels And Functions For Distribution And Transmission ISP/OSP Style Splice Closure Styles And Function Cable Entry Methods And Splitter Configurations Drop Cable Connectivity And Security Cable Installation Methods As Direct Bury, Aerial And Ducted Emergency Restoration Issues, Future Planning, Restoration Kits Safety Practices Topologies For Urban And Rural Communities Splitters, ONTs/OLTs/ODNs Intro To Optical Testing And Troubleshooting. Visible Light Sources, OTDRs And Power Meters Testing Methods For ISP/OSP Systems OTDR Test Functions And Trace Interpretation Optical Loss Testing Methods And More Target Audience Inside Plant/Outside Plant technicians, contractors, union craftsman, electricians, technicians, installers, splicers, engineers, facilities managers, telecom managers and anyone involved in repairing, installing, maintaining, designing, evaluating, or provisioning Fiber Optic Cables and Optical Networks. Prerequisites A basic understanding of telecommunications. This information can be obtained in our courses below or equivalent knowledge TeleCom Networks Today "II" Basic Telephony & Telecom Electronics Course Outline Page: 2 of 7

MODULE I FIBER OPTIC GENERAL STUDIES INTRODUCTION Common Industry Terminology History of Fiber Optics Advantages/Disadvantages of Fiber Optics Basics of a Fiber Optic Communications System Fiber Types and Manufacturing Processes (VIDEO) Typical Transmission Rates for Voice, Video & Data Applications System Topologies Fiber Optic Standards THEORY TOPICS Theory of Light Electromagnetic Spectrum Total Internal Reflection (Singlemode) Refraction (Multimode) Index of Refraction (Refractive Index) Light Sources (LEDs & LASERs) Power (dbm/watts) Core/Cladding/Coatings Numerical Aperture Macro/Microbends Wave Division Multiplexing (WDM, CWDM,DWDM, etc.) Optical Switching Fundamentals FIBER TOPICS Optical Fiber Types Typical Fiber Specifications Multimode Optical Fibers Singlemode Optical Fibers Dispersion Characteristics Modal Dispersion Chromatic Dispersion FIBER CABLE TYPES Outside Plant Inside Plant Loose tube Gel Filled (OSP) Tight Buffered Distribution (ISP) Tight Buffered Breakout (ISP) Jumper Cables and Hybrids styles Reverse Oscillation Locator (OSP) Fiber Color Code Page: 3 of 7

MODULE II FIBER OPTIC SAFETY ISSUES SAFETY FIRST LASER Safety and Warning labels Types of LASERs LASER Output Power Levels Eye Safety Precautions Safe Glass Disposal Practices Food and Drinks Not Safe Proper Person Cleanliness Safe Work Surroundings Confined Spaces Issues TOOLS: Cable Jacket Fiber Coating Strippers Mid-Entry Tools Ring Tools Tube Splitters Knives Slitters Scissors/Snips Safety Tweezers MODULE III FIBER OPTIC CABLE INSTALLATION PROPER PLANNING Project Considerations Cable Pre-testing Cable Reels Identification and Handling Proper Cable Pulling Techniques Outdoor Cable Design Characteristics Direct Bury Cable Installation Directional Boring Methods Buried Cable Depths Man Holes and Vaults Cable Pulling Specifications Tensile Strength and Bend Radius Avoiding Installation Obstacles Grounding and Bonding Fiber Cables Identifying Cable Types Work Area Protection Issues Page: 4 of 7

MODULE IV FIBER OPTIC CONNECTORS Connector Types Different types Use of connectors ST Style Connector Assembly; Hand and/or Machine Polishing and Inspection SC Style Connector Assembly; Hand and/or Machine Polishing and Inspection Also Types: FC, LC, MIL-C Series, Biconic, etc. FIBER OPTIC ENCLOSURES Applications Patch Panels Distribution of Fiber LAN Media outlets Fiber Management Bays INSTALLING CONNECTORS Connector tools Each attendee will install connectors TESTING CONNECTORS AND JUMPER LOSS Measure loss of previously installed connectors Test loss of jumpers Fiber Testing Parameters Continuity Testing MODULE V FIBER OPTIC SPLICING SPLICING Mechanical and Fusion Splicing Fusion Splicer Types and Operations Precision Cleaver Operation Set-up Fusion Splicer and Cleaver Work Stations Practice Fiber Stripping, Cleaning and Cleaving Practice In-Line Fusion Splicing Practice Pigtail Fusion Splicing Qualify Acceptable Splices and More... Page: 5 of 7

MODULE VI FIBER OPTIC TESTING TESTING INFORMATION The db Scale and Units of Loss OTDR Functions for Testing OTDR Testing for Splices, Distances and Back Reflection OTDR Trace Guidelines The Dead Zone Trace Events and Interpretation Testing at Various Wavelengths System Loss Parameters Calculating System Loss Total System OTDR Testing Optical Loss Test Sets (OLTS) Referencing the Test Set First Measuring Cable System Loss Documenting Test results And more... Notes Fiber Optic Certification and On-Site Testing Available upon request.. Delivery Method Instructor led with numerous Hands-On labs and exercises. Equipment Requirements (This apply's to our hands-on courses only) BTS always provides equipment to have a very successful Hands-On course. BTS also encourages all attendees to bring their own equipment to the course. This will provide attendees the opportunity to incorporate their own gear into the labs and gain valuable training using their specific equipment. Course Length Page: 6 of 7

3 Days Page: 7 of 7