Installation and Commissioning Manual

Similar documents
Advance Stainless Steel Unvented Hot Water Cylinders for Heat Pump Systems. Installation and Commissioning Manual

ADVANCE ECB ELECTRIC COMBINATION BOILER

ADVANCE ELECTRIC THERMAL STORE

Twin Compressor Compact Heat Pump. Installation and Commissioning Manual

SEALED THERMAL STORE

INTRODUCTION STORAGE PRIOR TO INSTALLATION. Expansion Vessel Hose. Part No High Flow Rate Inlet Control Set. Part No.

S T O R E R A N G E C Y L I N D E R & G R A N T FEATURES: GRANT MONOWAVE UNVENTED DIRECT AND INDIRECT SINGLE-COIL CYLINDERS

Shoebox Heat Pump. Installation and Commissioning Manual

Shoebox Heat Pump User Manual

CROWN WATER HEATERS CPU10 - CPU15 CPOS10 - CPOS15

ADVANCE UNIVERSAL MULTI-FUEL THERMAL STORE

Heat Pump. Installation and Commissioning Manual

Alpha FlowSmart 25 and 50

Installation and Servicing Instructions. Alpha FlowSmart

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

Unvented Calorifier Range. Operating and Maintenance Manual. For Models & 500

ADVANCE STAINLESS STEEL UNVENTED HOT WATER SYSTEMS

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

MEGAFLO HE Iss 1

Installation and User Instructions Aquaheat Unvented Water Heaters Models: AH30H

INSTALLATION MANUAL. Ecoline Geo RI HP PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION

Multipoint Technical Data

Instructions for Use Installation and Servicing

High Temperature Plant Room Heat Pump

H o t Wa te r Syste m s. Senator Electric Flow Boilers. Making Life Simpler

AquaFlo II. Issue 3 December Please read these instructions carefully before commencing installation of the AquaFlo unvented water heater

Plant Room Heat Pump

New Zip AquaFlo. Stainless steel cylinders for mains pressure hot water

Installation & User Instructions

Megaflo Eco Unvented Direct & Indirect Solar Hot Water Cylinders

Installation and User Instructions HS10U, HS15U.

STAINLESSLITE ONE NAME. EVERY SOLUTION. UNVENTED MAINS PRESSURE AND VENTED WATER STORAGE CYLINDERS

SOLAR HEATING SYSTEMS

PANDORA HEAT BANKS OXFORD BROOKES, HARCOURT HILL. Operation and Maintenance. THERMAL INTEGRATION LTD. Tel: Internet:

THERMAL STORE MAINS PRESSURE SYSTEM

Mains pressure hot water for fast filling baths and powerful showers Simultaneous supply of water to all bathrooms Long life low maintenance hot

Multi-Elec COMPACTE BOILER

Installation & Technical Guide. Domestic & Commercial.

Schuco SS-TC/SC Cylinders

Alpha CombiMax 350 and 600

Combined electric boiler and domestic hot water store

ENERSTORE. Vented Hot Water Storage System INSTRUCTIONS PLEASE LEAVE WITH HOUSEHOLDER

Frequently Asked Questions

THERMAL STORE MAINS PRESSURE SYSTEM

Saving energy comes naturally to us.

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

HEATRAE SADIA. Installation and User Instructions for the UTC Undersink Vented Water Heater

STAINLESSLITE PLUS ONE NAME. EVERY SOLUTION. UNVENTED MAINS PRESSURE AND VENTED WATER STORAGE CYLINDERS

Where gas is not an option,

TECHNICAL MANUAL MULTI-ELEC STANDARD BOILER 09/2011 CODE:

TABLE OF CONTENTS TECHNICAL DOCUMENTATION 03. Technical Data Electrical Details Connection Details Dimensions Standing Losses

STAINLESSLITE PLUS ONE NAME. EVERY SOLUTION. UNVENTED MAINS PRESSURE AND VENTED WATER STORAGE CYLINDERS

Megaflo Eco Unvented Direct & Indirect Hot Water Cylinders

ZIP AquaFlo II. Models: Direct, Indirect and Solar Compatible. Unvented cylinder water heaters

MEGAFLO Eco Plus Solar Unvented Hot Water Cylinders 400L -570L

Extreme Domestic Hot Water Loading System TECHNICAL DOCUMENTATION. Issue 11/09

Water Heating Systems

Quantum. Installation, User and Service Manual. Hot Spring

economy environment engineering excellence Advanced Commercial Hot & Warm Water Solutions

INSTALLATION INSTRUCTIONS POINT OF USE WATER HEATERS EPU - US10 EPU - US15

Series 1000 & Storage Water Heaters

Mains Pressure Hot Water from an existing vented copper cylinder... Allows the cold water tank to be removed, freeing loft space.

Megaflo Eco Slimline Unvented Direct & Indirect Hot Water Cylinders 100L - 200L

Unvented Direct & Indirect Hot Water Cylinders (400L L)

Megaflo Eco Solar PV Ready Unvented Direct & Indirect Hot Water Cylinders 170L - 300L

CUBEflow Thermal Store Tank

WATER HEATERS. Simplicity, performance, comfort... Hydraflo. Unvented Cylinders. 125 to 300 litres, directly or indirectly heated.

smart line E SLE

The world s most advanced direct electric water cylinder

HOTFLO 10 / 15. Fitting Instructions and User Guide

POWERFLOW Series. Unvented Electric Storage Water Heaters. Installation & Operating Instructions Manual

Plus. USER and INSTALLATION INSTRUCTIONS. 30,000-9kW for Heating and Hot Water

Installation and Servicing Instructions. Alpha GasSaver GS-1

UNIQ HEAT BATTERIES REFERENCE MANUAL_V2.2. Version: 2018_07_19_v2.2

Electromax Combined Electric Flow Boiler and Direct Unvented Hot Water Cylinder Installation and Servicing Instructions

pod Installation, Operation & Maintenance viridian Pod-PV, Pod-ST solar v

INSTALLATION MANUAL. Ecoline Geo RI HP PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION

A-Class. A-Rated Homes with Dimplex heat pumps. The name you can trust. Building Regulations and Part L Compliance made easy with Dimplex. dimplex.

Cistern-fed water heating

Installation & User Instructions

Unvented Electric Water Heater 10/15 litre Undersink

Xcel HEATBANK Thermal Store The solution to multi-fuel heating. Renewable Energy Solutions

Amptec. Electric flow boiler

CPC-150-ABIAB. Important Installation Notes.

Furrows Business Park, Haybridge Road Wellington, Telford, Shropshire TF1 2FE

UNVENTED MAINS PRESSURE SOLAR WATER HEATERS 210, 250 AND 300 LITRE CAPACITY INDIRECT MODELS INSTALLATION AND SERVICING INSTRUCTIONS

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

XCEL HEAT BANKS Installation Instructions. Thermal Integration Ltd., 1-3 Wealdstone Road, Sutton, Surrey SM3 9QN.

ADVANCED WATER COMPANY LTD COPPERFORM. Advanced Water Company Ltd. Unvented Hot Water Cylinders. Supplied By Advanced Water Company Ltd

The Ultimate Solution for Electric Central Heating. Fusion. Comet

the electric heating company ELECTRIC BOILER HANDBOOK

Broag Pressurisation equipment

SATK 30 heat interface unit

INSTALLATION & TECHNICAL MANUAL

Installation and Servicing Instructions. Alpha GasSaver GS-2

EPU - WM30 EPU - WM 50 EPU - WM100

AquaCyl solar system solar water heating solution for the larger home with greater hot water demand (2 or more bathrooms in use simultaneously)

INTERCYL. INTERNAL EXPANSION EXCELLENCE

HEATBANK Xcel Thermal Store The solution to multi-fuel heating. Renewable Energy Solutions

Powerflow Unvented water heater

Transcription:

Manual Advance Buffer Vessels for Ground Source Heat Pump Systems Installation and Commissioning Manual Copyright 2015 Kensa Heat Pumps Ltd Page 1 of 12

Contents Page Section Description Page 1... Safety Information... 3 1.1... Access... 3 1.2... Lighting... 3 1.3... Tools and Consumables... 3 1.4... Handling... 3 1.5... Residual Hazards... 3 1.6... Freezing... 3 1.7... Disposal/decommissioning... 3 2... General Product Information... 4 2.1... Equipment Delivery and Handling... 4 2.2... Buffer Vessel Dimensions and Arrangements... 5 2.3... General Specification... 7 3.0... Typical Schematics... 8 3.1... Twin Coil Cylinder with Compact GSHP (Space Heating and DHW Production)... 8 3.2... Buffer Vessel Installation with the Shoebox Heat Pump... 9 4.0... Installation... 10 4.1... Electrical Connections... 11 5.0... Commissioning... 11 6.0... Warranty... 12 Page 2 of 12

1. Safety information Safe operation of this unit can only be guaranteed if it is properly installed and commissioned in compliance with the manufacturer s requirements. General installation and safety instructions for pipeline and plant construction, as well as the proper use of tools and safety equipment must also be complied with. Manufacturer:- Advance Appliances Ltd Unit 4 Coppice Side Industrial Estate Brownhills Walsall West Midlands WS8 7EX Tel: 01543 377723 Fax: 01543 360620 The product is designed and constructed to withstand the conditions encountered during normal use. Use of the product for any other purpose, or failure to install the product in accordance with these Installation and Commissioning Instructions, could damage the product, will invalidate the warranty, and may cause injury or fatality to personnel. 1.1 Access Ensure safe access before attempting to work on the product. Arrange suitable lifting gear if required. 1.2 Lighting Ensure adequate lighting, particularly where detailed or intricate work is required. 1.3 Tools and consumables Before starting work ensure that you have suitable tools and / or consumables available. 1.4 Handling Manual handling of large and /or heavy products may present a risk of injury. Lifting, pushing, pulling, carrying or supporting a load by bodily force can cause injury particularly to the back. You are advised to assess the risks taking into account the task, the individual, the load and the working environment and use the appropriate handling method depending on the circumstances of the work being done. 1.5 Residual hazards Many products are not self-draining. Take due care when dismantling or removing the product from an installation. 1.6 Freezing Provision must be made to protect products which are not self-draining against frost damage in environments where they may be exposed to temperatures below freezing point. 1.7 Disposal/Decommissioning A life time decommissioning service for this product is available. This is available on a return to base basis (carriage at users cost). Page 3 of 12

2. General Product Information This manual explains how to install and commission an Advance Buffer Vessel System with a Kensa Heat Pump. Buffer vessels are simply a tank that contains a volume of water, increasing the overall volume of the heating distribution system. This extra volume of water is designed to absorb any extra heat generated by the heating appliance in low load conditions, which the building does not yet require. If the building cannot absorb the extra heat generated the return temperature to the heating appliance (in this case a heat pump) will increase and will turn off. If the temperature drops in the water returning to the heating appliance, then it will turn itself back on. If this cycling occurs at a greater frequency than the minimum run time for the appliance this is classed as short cycling. The aim of a buffer vessel is to remove the possibility of any short cycling of the heating appliance. For a heat pump the minimum run time is set by the number of compressor starts within an hour. For a single compressor heat pump this is usually around four. This means that typically for low loads which are below a quarter of the maximum heat output short cycling can occur. The size of the buffer vessel and the temperature at which it operates will determine its effectiveness and efficiency. Kensa s system designs are specifically designed to be able to operate without a buffer vessel between the heat pump and heating distribution system to maximise the efficiency of the system. This is achieved by using the volume contained within the heating system itself as the buffer vessel. This means approximately 25% of the under-floor zones or radiators should remain hydraulically open, i.e. no control valves fitted. These areas should provide a minimum load on the heat pump to avoid short cycling. The areas that are left open should be areas where close temperature control is not required i.e. hallways, bathrooms, etc. For buildings where open zones are not desired, Kensa would recommend the use of a two connection buffer vessel or volume tank as this is the most efficient type of a buffer vessel and avoids the drop in efficiency associated with four connection buffer vessels. 2.1 Equipment delivery and handling. Factory shipment Prior to shipment, the Buffer Vessel unit is tested, calibrated and inspected to ensure proper operation. Receipt of shipment Each pallet should be inspected at the time of delivery for possible external damage. Any visible damage should be recorded immediately on the carrier s copy of the delivery slip. Each pallet should be unpacked carefully and its contents checked for damage. If it is found that some items have been damaged or are missing, notify the manufacturer immediately and provide full details. In addition, damage must be reported to the carrier with a request for their on-site inspection of the damaged item and its shipping pallet. Page 4 of 12

2.2 Buffer Vessel Dimensions and Arrangement Kensa Model number Advance model number 010A 012A 013A 014A 015A 018A 020A BFS80 BFS150 BFS215 BFS255 BFS305 BFS500 BFS 1000 025A BFS 2000 030A BFS 3000 Volume 80 150 215 255 305 500 1000 2000 3000 Dim A (mm) 645 1086 1485 1753 2030 2018 1800 2288 3040 Diameter D (mm) Immersion Heaters Weight Full (kg) 577 577 577 577 577 750 990 1290 1290 1x 3kW 1 x 3kW 1 x 3kW 1 x 3kW 1 x 3kW 1 x 3kW 1 x 3kW 1 x 3kW 1 x 3kW 105 180 260 305 355 600 1190 2385 3580 Note: Although the buffer vessel is provided with 4 x 28mm BSP connections up to 150 litres and 4 x 2 for larger sizes, only 2 connections should be used to provide the best efficiency at the heat pump. D Note: Although the buffer vessel is provided with an immersion heater this should not be electrically connected unless approved by Kensa Energy. The use of an immersion will reduce the efficiency of the system and increase carbon emissions. Note: An air vent should be fitted to the top 3/4 BSP connection to remove air from the system. It can be of the automatic or manual type. Page 5 of 12

420 600 Kensa Model 011A Advance Appliance Model BFS100 Volume (l) 100* Weight Full (kg) 145 Heat Loss kwh/24hrs@50 o C 2.05 Immersion Heaters 1 x 3kW 560 Top Immersion cover plate 1/2" Vent 28mm BSP Male Flow 1/2" Drain 1/2" Thermostat Front 100 litre Buffer Vessel 28mm BSP Male Return Note: Although the buffer vessel is provided with a 3kW immersion heater this should not be electrically connected unless approved by Kensa Heat Pumps. The use of an immersion heater will reduce the efficiency of the system and increase carbon emissions. Note: Although 4 tappings are provided only 2 should be connected via a t-piece to the flow and return to maintain the heat pump efficiency. Page 6 of 12

2.3 General Specification Tappings 4 x 28mm Male (80, 100 & 150L) 4 x 2 Male (for larger sizes) Inner Container & Connections Duplex Stainless Steel Except * Mild Steel (100litre) Material Outer Casing Insulation Plastisol Mild Steel (100litre) Polyurethane and mineral wool Max Operating Pressure and Temperature Hydraulic Test Pressure Insulation Insulation 50 & 100 Litre Tank Thermostat Probe Pocket Air Vent 3 Bar 95 o C 2.5 Bar 95 o C 50 & 100 litre tanks 9 Bar 3.5 Bar 50 & 100 litre tanks Polyurethane Foam Injection Rigid Polyurethane and Mineral Wool Fitted to cylinders, 1/2 BSP on 100 litre tank 3/4 BSP tapping cylinders 1/2 tapping fitted on 100 litre Tank Shell and Domes to be designed generally in accordance with BS5500 Page 7 of 12

3.0. Typical Schematics 3.1 Twin Coil Cylinder with Compact GSHP (Space Heating and DHW Production) Abbreviations 3PDV - 3 port diverting valve BV - Buffer Vessel DHW - Domestic Hot Water CW - Cold Water EXP - Expansion vessel GSHP - Ground source heat pump IH - Immersion heater IV - Isolation valve PRV - Pressure relief valve SM - Slinky manifold T - Thermostat UFM - Under-floor manifold WP - Water pump If full control of all heating zones is required the Buffer Vessel (BV) can be fitted (as shown) to reduce short cycling of the heat pump. If 25% of the under-floor zones and radiators are left open this is not normally required. Please note:- The above drawing is a schematic only and additional valves and fittings maybe required. Please note:- Running the GSHP to produce DHW with off-peak tariffs might result in the GSHP needing to operate during peak electricity periods for space heating with higher associated running costs. Page 8 of 12

3.2 Buffer Vessel Installation with the Shoebox Heat Pump Bypass valve Shoebox DHW with under-floor and a buffer vessel If close temperature control of all heating zones is required, it is recommended that a buffer vessel is fitted. The above schematic shows how a buffer vessel can be incorporated into the shoebox installation without the need of a second water pump. The buffer vessel allows all radiators or under-floor zones to be fully controlled and prevents the shoebox from short cycling, hence removing the need for open zones. The buffer vessel is connected to a bypass valve which is set at 0.4 bar. As the heating zones throttle down due to the heating requirement being satisfied, the pressure in the heating circuit increases. Once this pressure increases above 0.4 bar, the bypass valve opens, diverting the flow through the buffer vessel maintaining a load on the heat pump and avoiding it from short cycling. Page 9 of 12

4.0 Installation Please read this leaflet carefully before installation of the product. You should be competent to install the unvented system as defined by the regulations. Please pay special attention to maintenance and service. Please keep the unit packaged until you are ready to commence installation. The unit should be stored vertically in a dry area, and all safety components kept in the box. Install in an area that will be accessible in the future When first fixing take into account that the connections and controls will be front facing to facilitate access. If using push fit connections i.e. Speedfit attach a piece of copper pipe initially to the vessel stainless steel connection via means of a compression fitting. The push fit connection then can be attached to this. Failure to do this may well cause any push fit connected directly onto the vessel to leak. Mount the unit vertically on a flat even surface. Please note:- If used in conjunction with the Shoebox heat pump the circulation pump is required to be fitted before the buffer vessel and a bypass valve fitted on the buffer vessel inlet (See section 3.2) Check that the floor will support the unit when it is full of water. See page 5 for weights. The unit has a maximum working pressure of 6 bar. Good system design should take this into consideration & pipe sizing should be in line with current good practice. Page 10 of 12

4.1 Electrical Connections Although fitted with immersion heaters, Kensa advise that these should not be electrically wired and connected unless approved by Kensa Heat Pumps. The immersion heater should only be used as a back up in very cold weather as use of the immersion heater will result in higher running costs and higher carbon emissions. To reduce the effect on cost, if the immersion heater is used then this should be via an off-peak tariff such as economy 7 or economy 10 tariffs. Immersion heaters are rated 3kw at 240v (2.76kw at 230v), incolloy elements, with a thermal energy cutout, and must be connected via double pole switches with a 3mm contact gap separation. Appropriate wiring for the electrical load must be used. Do not switch on until the unit is full of water. Do not fit an immersion heater without a high limit thermostat. Immersion heaters supplied are designed for domestic use only, either utilising low tariff electricity and occasional boost or for switched periods during the day. Units must be earth bonded. Immersion heaters must meet BS EN 60730-2-1. Fuse rating for 6kw loading is 25 amps, for 3kw models fuse rating is 13 amps. 5.0 Commissioning Before filling, check expansion vessel charge is at 3.0 bar. 1. Open the main supply to the unit. 2. Flush the unit through until all air is expelled, (a vent should be fitted to the top of the unit to facilitate this. 3. Ensure inhibitor is added to the system as required 4. The system is now full of water. Check for any leaks on pipe-work or joints or components such as immersion heaters etc. It is the installers responsibility to check all fittings, including those that are fitted to the unit. 5. Switch on power and heat up via heat pump. 6. Your system should now be ready for use. Page 11 of 12

6.0 Warranty Advance Appliances guarantees the shell of the stainless steel units for 25 years. The compact mild steel units are guaranteed for 2 years. The component parts are guaranteed for 2 years from date of purchase. The following information is important without it your guarantee may be invalid 1. Keep proof of purchase 2. Ensure that installation has been carried out correctly by appropriately approved/ competent personnel following relevant Code of Practice. 3. Installation must be in an appropriate location and use is restricted to central heating systems with the appropriate levels of inhibitor added.. Private water supplies are excluded. Please note that the extended guarantee is not transferable, and rests with the original householder. The above does not affect your statutory rights. Every effort has been made to ensure that this information is correct. Regulations may change and installers must adopt best current practice. Advance Appliances/Kensa reserve the right to alter or improve components or specification without notice. Page 12 of 12