EnergyGauge USA Release Notes

Similar documents
EnergyGauge USA Release Notes

Rater Provider Monthly Webinar REM Rate Modeling Tips March 23rd 2013

ENERGY STAR V2.5 & 3 Designed to Qualify AIA Annual Convention

Address Account # Member # Equipment Specifications Quantity Rebate. ENERGY STAR Appliances

Residential Track Unit 10 Understanding the Residential HERS Rating

Equipment Specifications and Required Information Quantity Rebate

How to Obtain an AHRI Certificate

2014 Florida Energy Code Software Verification Test Report: EnergyGauge USA version 4.0

RESNET HERS Rater Sample Test Questions 2

Single-Family Weatherization Baseline Assessment (R5) Final Report

WHAT S CHANGED WITH ANSI/RESNET/ICC STANDARD 380. Iain Walker, Residential Building Systems Group

Duct Leakage, Sealing & Testing

Procedures for Verification of RESNET Accredited HERS Software Tools

Residential Air Leakage (Blower Door) Testing for Florida Code Compliance

BALTIMORE GAS AND ELECTRIC COMPANY (BGE) Home Performance with ENERGY STAR Program. Rebate and Incentive Instructions

Pro Eco-Energy. Home Assessment

COMcheck Software Version Interior Lighting Compliance Certificate

ENERGY SYSTEMS LABORATORY

UNDERSTANDING AND USING THE HVAC DESIGN REVIEW FORM

Closing the Gap: Getting Full Performance from Residential Central Air Conditioners. Task 4 - Develop New Climate-Sensitive Air Conditioner

NAHB Green Home Building Guidelines. 3.1 Prerequisites. ResCheck. Energy Efficiency

Overview. Case Study 2008 Building America Prototype ICI Showcase House. Daytona Beach, Florida. Project Team: ICI Homes, Building Science Corporation

Ventilation. ASHRAE 62.2 COMPLIANCE How do we get there? Bruce Hagen ND Dept. of Commerce.

AN ANALYSIS OF THE RESIDENTIAL ENERGY SAVINGS FROM THE IMPLEMENTATION OF THE 2001 IECC AND 2006 NAECA APPLIANCE STANDARDS IN THE STATE OF TEXAS

Residential New Home Construction Checklist

Energy Efficient Measures That Add Little or no. Program Lights & Appliances: How To Benefit from the Low-Hanging Fruit

2009 Washington State Energy Code Residential Sections

Maine Single-Family Residential Baseline Study

MF Mechanical Systems. Doug McCleery, PE, CEM March 2, 2016

CITY OF DANA POINT. COMMUNITY DEVELOPMENT, BUILDING AND SAFETY Golden Lantern, Suite 209 Dana Point, CA

Interim Report for the Period thru February 15, 2018 Submitted to Department of Business and Professional Regulations Office of Codes and Standards

wattsmart New Homes Contractor-Certified HVAC Quality Assurance (HVAC-QI)

Energy Upgrade California Home Upgrade Offered by The Energy Network

Home Performance Program Healthy, Comfortable & Efficient

PART 5: HVAC & DHW SYSTEMS

Massachusetts Energy Code Technical Support Initiative

Monty Anderson Construction Group Home Address: 3251 Great Oaks Boulevard Kissimmee, FL Certified: Score: 164

RESNET Rating Field Inspector Field Evaluation Form

Multifamily Weatherization:

MultiFamily Ventilation Updates: ASHRAE 62.2, Best Practices and Practical Applications RESNET Conference Atlanta, GA

RECOMMENDATIONS FOR 15% ABOVE-CODE ENERGY EFFICIENCY MEASURES FOR RESIDENTIAL BUILDINGS

COMcheck Software Version Mechanical Compliance Certificate

Performance of Solar Water Heating Systems in the United States

2015 NATURAL GAS EFFICIENCY REBATE APPLICATION

COMcheck Software Version Mechanical Compliance Certificate

2016 BUILDING ENERGY EFFICIENCY STANDARDS RESIDENTIAL HVAC ALTERATIONS

SR SERIES WATER SOURCE HEAT PUMP SYSTEM SELECTION AND OPTIMIZATION GUIDE

Earning HERS Points for Quality HVAC Design & Installation. Tuesday, February 26, 2019

SBEC Residential Energy Efficiency 2019 Rebate Programs for Existing Homes

The Bryant is more than just a pretty face, this is one hardworking home.

Monitor Alarms and Events

Chapter Eight RESNET Standards

The Benedict 1 H O M E. Dream. Build. Live. 3 BEDROOMS 2.5 BATHROOMS 2,549 SQUARE FEET *

Are you Getting Your Fan Flows Right?

UPGRADES. [Energy Efficiency] Base Points

Massachusetts Energy Code Compliance Support Commercial Energy Code Building Mechanical & Service Water Heating Provisions

MANUAL J/S Summary One summary sheet for each system

MONTANA HOUSE 2 TECHNICAL SPECIFICATIONS June 28, 2011

1 INNOVATION & INTEGRATION: Transforming the Energy Efficiency Market Buildings.Energy.gov

SINGLE-FAMILY RESIDENTIAL NEW CONSTRUCTION CHARACTERISTICS AND PRACTICES STUDY. Final Report

Copyright 2017 Integrated Environmental Solutions Limited. All rights reserved.

Welcome. High Performance Mechanicals for Houses That Work. Energy Design Conference - Duluth, MN. February 21 st, 2018

Bathroom SAVING ENERGY AROUND THE. If you go on vacation, turn the temperature selector to the lowest setting.

MBPA Home Performance FIELD DATA COLLECTION FORM

When Duct Sealing Kills HVAC Equipment and Efficiency

Procedures for Verification of RESNET Accredited HERS Software Tools

Audit Date: Auditor: Jimmie Sparks Client Name: White Bear Lake Audit Phone: x123 Neighborhood Energy Connection

New Jersey Board of Public Utilities and its Clean Energy Program. Residential Energy Efficiency Programs. NJCleanEnergy.com

InterNACHI Home Energy Inspection for th Street

The V in HVAC: Mechanical Ventilation in ENERGY STAR Certified Homes

Ways to Save. Energy efficiency tips to help you lower your monthly power bill. 1 Ways To Save

NEW FEATURES IN THE CARRIER HOURLY ANALYSIS PROGRAM v4.80

ENERGY & WATER EFFICIENCY: HOME ASSESSMENTS. Jim Riggins Monument, CO

Bedroom 100. True or False: Space heaters are more energy efficient and inexpensive to heat large areas than central heating systems.

Missouri HERO Program Residential Eligible Product List

Modular Construction. Live/Work Urban Infill Townhome. Modular Construction. Enclosure Design. San Francisco Bay Area Net Zero Urban Infill

Bathroom SAVING ENERGY AROUND THE. If you go on vacation, turn the temperature selector to the lowest setting.

EXHIBIT 1. Washington Home Energy Savings

Customized Energy Audit Report

ERRATA SHEET FOR ANSI/ASHRAE/IES STANDARD (I-P Edition) Energy Standard for Buildings Except Low-Rise Residential Buildings.

Installing ProSeries software for stand-alone use

Conservation & Energy Efficiency Activities

inviting entryway creates a great first impression, quickly followed by an open concept great room that

SAVING ENERGY AROUND THE

EXHIBIT 1. Washington Home Energy Savings Program Measures, Incentives, and Qualifications

CARRIER edesign SUITE NEWS. Modeling 100% OA Constant Volume Air Systems. Volume 6, Issue 1. Page 1 Modeling 100% OA Constant Volume Air Systems

COMcheck Software Version Mechanical Compliance Certificate

ENERGY STAR Qualified Homes

What's new in LogTag Analyzer 2.8

2011 NATURAL GAS EFFICIENCY REBATE APPLICATION

Public Utility Commission of Texas. Texas Technical Reference Manual Version 4.0 Volume 2: Residential Measures Program Year (PY) 2017

SUPPORTING DOCUMENT RESIDENTIAL ENERGY CODE WORKSHEET (2015) EFFECTIVE JANUARY 1, 2017

Your Energy Management Partner

The Maybeck. Dream. Build. Live. 4 Bedrooms 3.5 Bathrooms 3,046 Square Feet *

BSR/RESNET Standard for the Calculation and Labeling of the Energy Performance of Low-Rise Residential Buildings using the HERS Index

COMcheck Software Version

LEED for Homes V4 Provisional Alternative Compliance Paths for the Canadian market March, 2017

Building Codes, Ventilation Rates, and Certified Performance. Ventilation Track Comfortech 2007 St Louis, MO September 27, 2007

Audit Date: Auditor: Sarah Hayden Client Name: College of St Benedict Audit Phone:

1. When using the COMcheck software, the compliance report submitted by the permit holder shall indicate that the applicable code is.

Transcription:

EnergyGauge USA 6.0.00 Release Notes The latest release of EnergyGauge USA, Version 6.0.00 includes 2017 Florida Building Code, Energy Conservation, 6 th Edition performance code and bug fixes. KEY FEATURES ADDED Florida Building Code 6 th Edition (2017) Energy Conservation performance calculation implemented Added mechanical ventilation option of RuntimeVent w backup that models a supply side runtime ventilation system when cooling/heating system is on and a supply/exhaust or balanced fan when cooling/heating system is not on. Updated software to allow extensive entries of walls and systems for large houses with multiple spaces. ENERGY STAR Rev. 09 changes have been implemented (Rater versions). Manual S Procedure has been expanded (SizePro versions). Sped up the save, calculation and load ENB functions. Sped up the hourly report generation. Smart ventilation features expanded. Added database version on Help > About. WINDOWS VERSIONS SUPPORTED Windows Vista, Windows 7, Windows 8, Windows 8.1 or Windows 10. GENERAL BUG FIXES/ENHANCEMENTS Check for available updates no longer causes an error message when an internet connection is unavailable. Summary screens following calculations brought to front (In some cases they were hidden) Program now populates duct tightness results, if entered, on duct leakage test reports printed from EnergyGauge. Title of message associated with total of wall, window and door area seem small was changed from an error to a warning. Title of message associated with "total window area seems large" has been changed from an error to a warning. The window screening on the Window page is now enabled in all versions of software and does not require Parameters and Schedules to be enabled.

Highly efficient tankless water heater calculation limit has been fixed and may result in minor change of result. Removed non asci characters that might be entered or come with file import to reduce calculation/reporting or rater registration issues. Test Date on Infiltration page is now enabled after selecting Clear Date. Interior walls should no longer cause a file to crash. Changing building status will not cause a project to be deleted. Improved error checking when entering a mechanical ventilation system. Window orientation error should not display after changing the building orientation and then saving file. Range Check error should not display when viewing reports after calculating FL Code and other calculations for additions. The term "Location" on the lighting screen no longer partially obscured by selection field. Added through 2018 to year of construction selection. Removed Number of Bathrooms from Input Summary Report as entry had already been removed. Additions no longer require AC SEER input for None (Baseline Assumed). Add error checking for all lighting, fans and appliances during calculation that verifies name of each space exists on the spaces page. Avoids error that might occur if space was deleted after selecting it. Added an error check for doors assigned to interior walls. Added error checking for negative area in garage ceiling under unconditioned space field Updated labels on input summary form. Added error check limiting the depth below grade of walls. Added error checking if the multiple heating/cooling box is selected that there are entries in the multiple system entry form. Calculation error when different duct systems were assigned to heating and cooling was fixed. Limited the Tested Coil Airflow significant digits Input summary includes impact column for windows. Fixed a bug giving erroneous results for homes with multiple mechanical ventilation systems. Fixed a bug regarding the project query on the search screen. Project screen label model no longer obscured by other data. Fixed database verification error user received. Utility cost data was updated. Pennsylvania average utility selection no longer causes Energy Gauge to freeze.

FLORIDA CODE CHANGES AND OTHER FEATURES Anticipated code changes in 2017 that may impact result relative to 2014. 2017 Florida Building Code, Energy Conservation, 6 th Edition effective date Dec. 31, 2017. Component 2014 FEC 2017 FEC Anticipated Effect Reference Skylight None Included Less Stringent (if applicable) Reference Air Exchange Rate 7 ACH50 (post 2016 Supplement) 7 ACH50 No Impact from EGUSA version 5.003 Proposed House Thermal Distribution System Efficiency (untested) Reference glazing (window) area for multifamily projects Reference Gas Furnace Efficiency DSE = 0.88 Qn out =0.080 (now leakage level specified instead of DSE) 0.56 Backstop 0.80 Backstop Impact between codes will vary based on roof/attic configuration, duct location, on some houses no changes, on others may be more or less stringent (applicable to all nontested duct systems) Less Stringent (if applicable) 0.78 EF 0.80 EF More Stringent (if applicable) 2017 Performance code available in this version, ERI and prescriptive coming soon. Worst Case Summary under reports no longer displays an error if selected after running FL Code 2014 Performance calculation. Set the FL Code 2014 Std Ref SEER to 12 when a user building has a small duct high velocity system and set the FL Code 2014 Std Ref heat pump HSPF to 7.7 when a user building has a small duct high velocity system. Skylight with zero tilt should not cause a window orientation error on rotation of building and running FL Code calculation. FL Code prescriptive path 402 should pass when Proposed Leak Free duct leakage is selected An unvented attic should pass FL Code 2014 prescriptive if the roof deck is insulated to the mandatory value. Fixed error where FL Code 2014 calculation would crash with concrete roof and framing fraction of 0.00. Change error message on FL Code calculation to require proposed ACH50. IECC climate zone removed from detailed input summary and R405 Input summary reports; Florida climate zone remains in header of report. Florida additions corrected to use Qn Total as the duct leakage requirement. Removed choice of Alternative (new) from hot water selections for additions. When selecting heating system of type heat pump and subtype single requires an HSPF of 8.0, not 8.2.

IECC CODE CHANGES AND OTHER FEATURES Climate zone is now included on IECC reports. Added a default DHW for IECC calculations if one is not entered and displays a message to user. "No hot water system entered, a default one will be entered for the required calculation (OK, Cancel)." 2009 IECC requirement for unconditioned basement walls should pass with insulation on walls or floor. It was only passing with insulation on floors. This should also be allowed for ENERGY STAR. Removed Heat Trap/Insulation from IECC 2015 Reference home. IECC 2015 R Value menu item was missing the closing bracket after (402 HOURLY REPORTS Fixed bug related to selecting natural gas for heating on hourly report generator. Speed of creating hourly report greatly increased. SMART VENTILATION (for annual simulation calculations only) Changed name from Ventilation Override to Smart Ventilation Smart ventilation changed to none during HERS or code calculations (No change from earlier) This feature now allows the user to choose from four different procedures for calculating the smart ventilation energy use including direct entry of fan wattage at different ventilation rates Bar charts on smart ventilation page show when system will turn on or off Preset entries specific for each type of control system by selecting the plus button. No need to enter total fan capacity for smart ventilation. HERS RATERS CHANGES AND OTHER FEATURES (Rater versions) ENERGY STAR Rev. 09 changes have been implemented o SAF is eliminated from Energy Star 3.1 calculations, o Gas furnace AFUE is 0.80 for reference in Climate Zone 3, o Reference tankless gas water heater should be 50 gallon gas o Reference home 0% efficient lighting in exterior and garage. ENERGY STAR IECC 2009 now allows unconditioned basement walls or floor over the basement to be insulated on Total UA calculation. HERS Rated home now uses the same clothes washer as the reference home if there is no clothes washer entered. It was set to default new clothes washer which was better than the reference home which uses a 2006 model. The effect of this change is considerably greater dryer energy use if there is no clothes washer entered. This increases the HERS index for homes without clothes washer entries. Removed message on loading project that the entry is being set to HERS2014. Exposed floor area XXX compared to ceiling area XXX violates RESNET limit should not display if they are in range.

RFIIN/RTIN is now displayed on verifier page on project site tab. Input summary will not show incandescent as light bulb type based on qualified fixtures. Add an error check for a hot water system for HERS calculation. The message could be ignorable. Modified the ENERGY STAR Compliance Check to allow for ASHRAE 62.2 2010 or 2013. Updated RESNET Disclosure form to one amended on 3/20/17. Add a duct system with DSE of 0.80 to the rated home if cooling and/or heating are missing. Unconditioned basements had double lighting loads, this has been fixed. HERS Reference home should always have lighting in main space, there were instances where it was not. Change Input Summary title to Display Rated Design Summary Report when the HERS Rated Home is viewed. Also added a signature page on the last page. Change Input Summary title to Display Reference Design Summary Report when the HERS Reference Home is viewed. Also add a signature page on the last page. Crash on calculation due to incorrect duct size entry has been fixed. HERS Summary report accounts for mechanical ventilation energy as separate from heating and cooling [This may impact HERS index for homes with mechanical ventilation systems]. HERS REGISTRATION SYSTEM RELATED (some of these changes already implemented) A space at the beginning or end of the project title or address or rater name in the RGU should no longer result in audit with cause. Replacing of pdf files with updated ones should not delete files if project does not complete registration process. Added error check to ensure Verifier Name and/or Verifier Task are not empty. Error checking added for saving rgu files with non asci characters. Disabled the manual entry of the ENERGY STAR version from the create RGU process. This has caused the registration to fail RESNET upload if it is not entered correctly. MANUAL S (SizePro versions) Manual S entry and reporting features are now more detailed. The software allows you to enter specific equipment and save that equipment for further home entries. Once completing the Energy Gauge Manual J calculation (step 1) the software guides you through the remaining four steps (steps 2 5 below). See the software HELP system for more information. STEP 1: Determine heating and cooling loads for each room in the building STEP 2: Estimate Airflow Temperatures STEP 3: Enter the AHRI Heating and Cooling Equipment information for this project STEP 4: AHRI Heating and Cooling Capacities and Efficiencies at AHRI Test Conditions STEP 5: Original Equipment Manufacturer s (OEM) Specifications at Design Conditions