CCC 2018 GROUP A PROPOSED CHANGES TO THE I-CODES COLUMBUS COMMITTEE ACTION HEARINGS. April 15 23, 2018 Columbus Convention Center Columbus, Ohio

Similar documents
IRC - BUILDING - ELECTRICAL - ELECTRICAL TAC

Code Technology Committee Meeting #31 March 31-April 1, 2015 Care_WTC Recommendations/Elevators

2015 International Fire Code

IPC CODE AND COMMENTARY

Attention: Sharon Dickinson, Legislative Assistant, Planning and Land Use Management Committee

PROPOSED CODE CHANGES FOR REVIEW BY THE FIRE CODE ACTION COMMITTEE

International Code Council

Commerc al K tchen Hood

Fire Plan Review and Inspection Guidelines

Code Technologies Committee Report Fire Rated Glazing Group A changes: Fire rated glazing

CODE TECHNOLOGIES COMMITTEE NURSING CARE FACILITIES WORK GROUP APPROVED CODE CHANGE DRAFTS CODE GROUP B

ICC CODE TECHNOLOGY COMMITTEE Area of Study Labeling of Fire Rated Glazing

F Int ernat ional Building Code. Revise as f ollows:

Code Technologies Committee Report Elevator Lobby Group A changes: Elevator Lobby

Following are code change proposals submitted through Adhoc Health from General study group and related changes. General. Position.

Recommended Amendments to the 2015 International Existing Building Code North Central Texas Council of Governments Region

IBC Committee Responsibility Matrix January 2017

ICC code change proposals are being reviewed, evaluated, prioritized, and desired results determined by the BHMA Task Group working on the proposals.

2018 International Fire Code. Add new text as follows:

Building Code Basics: Fire. Based on the 2012 International Fire Code

AD HOC HEALTHCARE COMMITTEE MEANS OF EGRESS WORK GROUP APPROVED CODE CHANGE DRAFTS CODE GROUP B MOE COMMITTEE

International Fire Code

2018 IFC Update. Based on the 2018 International Fire Code, (IFC ) Goal. Objectives. Content

Proposed Changes to NFPA

Tire Storage. Michigan Fire Inspectors Society Fall Conference

2012 International Fire Code Significant Changes. IFC Background. Purpose IBC and 2012 NFPA 101 Significant Means of Egress Changes

AdHoc Committee on Healthcare Meeting #14 April 1-2, 2015 AHC Group A Changes (Agenda Item 5.0)

6) 7) 8) 9) 10) Complete the

ERRATA TO THE 2000 INTERNATIONAL FIRE CODE. Fourth Printing, January 2002 Updated March 29, 2002

INTERNATIONAL FIRE CODE

Report on First Revision June 2014 NFPA 5000

Report on First Revisions with Statement June 2014 NFPA 101

NFPA 101, 2012 EDITION IMPACT ON NEW AND EXISTING HEALTH CARE FACILITIES

Date of Authorization May 26, 2005 BMEC Authorization BMEC Application # A

ICC 902/ APSP 902/ SRCC Solar Pool and Spa Heating System Standard

Code Technology Committee Area of Study Balanced Fire Protection Roof Vents

IFC Significant Changes from the 2009 to the 2015 Edition Tier 1

Summary of BBS Proposed Ohio Plumbing Code Rule Changes October 2016

Summary. Code Technologies Committee has submitted 6 public comments: FS42-15, EB58-15, G9-15, G33-15, G200-15, P34-15

IPMC 2016 GROUP B PUBLIC COMMENT AGENDA

Australian Standard. Degrees of protection provided by enclosures (IP Code) AS IEC Ed 2.1:2001 AS 60529

Fire-Rated Glazing Changes in 2012 International Building Code (IBC)

Second Revision No. 104-NFPA [ Section No ] Submitter Information Verification. Committee Statement

Report to Adhoc Health Code change proposal regarding locking arrangements From John Woestman, BMHA

INTERNATIONAL FIRE CODE

INTERNATIONAL FUEL GAS CODE

DENVER AMENDMENT PROPOSAL 2015 INTERNATIONAL CODES

M E M O R A N D U M. NFPA 5000 A2011 ROP Letter Ballot

M E M O R A N D U M. NFPA Technical Committee on Alternative Approaches to Life Safety. SUBJECT: NFPA 101A ROP TC Letter Ballot (A2012 Cycle)

Fire Department HEADQUARTERS Cathedral Oaks Road Santa Barbara, CA (805) FAX: (805) CODE SUMMARY

9/23/ :20 AM. Second Revision No NFPA [ Section No ] Supplemental Information. Submitter Information Verification

LOCAL AMENDMENTS TO THE INTERNATIONAL FIRE CODE 2006 EDITION

Fire and Life Safety Committee

Significant Changes to the 2012 IFC Semiconductor Fabrication Facilities. Scott Stookey Senior Technical Staff International Code Council, Austin TX

2007/2008 PROPOSED CHANGES TO THE INTERNATIONAL FUEL GAS CODE FUEL GAS CODE COMMITTEE

Analysis of Changes for the 5 th Edition (2014) of the Florida Codes

Report on First Revisions with Statement June 2014 NFPA 101

Interim Amendments to Ontario s 2012 Building Code Retirement Homes. August 17, 2017

Fire Code Action Committee (F-CAC) Meeting Minutes June 19-20, 2012 Chicago IL. Summary of Actions and Regional Work Group (RWG) Assignments

Fire Protection Essentials QA/QC Plan Sample

Public Input No. 4-NFPA [ Section No. 4.2 ] Statement of Problem and Substantiation for Public Input. Submitter Information Verification

BCBC 2012 CHANGES TO PART 3

Brighton Area Fire Authority

Resolution: FR-2-NFPA Statement: The new language requires the action completed by NFPA 557 be prepared by a person that is approved.

Fxx - 13 K-66 Smoking Regulations (New)

MULTI-LEVEL & COVERED BOOTH CONDITIONS

Letter of Recognition

June 20, 2011 PARTIES INTERESTED IN FIXED CONDENSED AEROSOL FIRE-EXTINGUISHING SYSTEMS

Committee Input No NFPA [ Global Input ] Submitter Information Verification. Committee Statement. 1 of /20/ :02 AM

ARTICLE 25. FUEL GAS CODE

UPDATES TO THE 2015 PROPOSED CHANGES TO THE INTERNATIONAL CODES

Defend In Place 2012 IFC Overview of Institutional Occupancies

S000 SITE REVIEW APPR NO. FIRE CODE COMPLIANCE ITEM

COMPLIANCE ALTERNATIVES

British Columbia Building Code 2006 Division B Part 3 Fire Protection, Occupant Safety and Accessibility Section 3.2 Building Fire Safety

FIRE-RESISTANCE-RATED CONSTRUCTION A Primer on IBC Chapter 7

FIRE/SMOKE BARRIER FUNDAMENTALS

Report on First Revision June 2014 NFPA 101

Major Changes to the 2010 National Construction Codes Contractor s Breakfast January 2014

IMO UNIFIED INTERPRETATIONS TO SOLAS CHAPTER II-2 AND RELATED FIRE TEST PROCEDURES

Level I Chapter 1 Worksheet

WORKING DRAFT OF COMMITTEE MEETING OUTPUT

Tennessee Department of Health Bureau of Health Licensure and Regulations Division of Health Care Facilities

Solution Ultima Series Operators Manual ISSUE 1.00


First Revision No. 2-NFPA 90B-2012 [ Section No. 1.3 ] Submitter Information Verification. Committee Statement and Meeting Notes

SC # /16/17/18/19/23/24 D#03-24

CHAPTER 8 CHIMNEYS AND VENTS

EVALUATION SUBJECT: DIVISION: HEATING, VENTILATING AND AIR CONDITIONING (HVAC) SECTION: HYDRONIC PIPING.

9/20/2016 2:53 PM. Second Revision No NFPA [ Section No ] Supplemental Information. Submitter Information Verification

Recommended Amendments to the 2003 International Fire Code North Central Texas Council of Governments region

For the Florida Building Commission And the Fire Code Advisory Council

F, T, L and W Ratings - What are the Code & Testing Requirements?

***DRAFT - NOT FOR FILING***

U.S. Codes & Standards for Energy Storage Systems. Joe Cain, P.E. Chair, SEIA Codes & Standards Working Group

2015 National Fuel Gas Code Summary List of Revisions Updated: 04/24/14

Building & Fire Code Academy. Building Better With Our Greatest Resource Education. Welcome!

PERFORMANCE COMPLIANCE METHODS

Town of Cicero Local Code Amendments

INITIAL FIRE SAFETY ASSESSMENT

Transcription:

CCC 2018 GROUP A PROPOSED CHANGES TO THE I-CODES COLUMBUS COMMITTEE ACTION HEARINGS April 15 23, 2018 Columbus Convention Center Columbus, Ohio

First Printing Publication Date: February 2018 Copyright 2018 By International Code Council, Inc. ALL RIGHTS RESERVED. This 2018-2019 Code Development Cycle, Group A (2018) Proposed Changes to the 2018 International Codes is a copyrighted work owned by the International Code Council, Inc. Without advanced written permission from the copyright owner, no part of this book may be reproduced, distributed, or transmitted in any form or by any means, including, without limitations, electronic, optical or mechanical means (by way of example and not limitation, photocopying, or recording by or in an information storage retrieval system). For information on permission to copy material exceeding fair use, please contact: Publications, 4051 West Flossmoor Road, Country Club Hills, IL 60478 (Phone 1-888-422-7233). Trademarks: International Code Council, the International Code Council logo are trademarks of the International Code Council, Inc. PRINTED IN THE U.S.A.

CCC-F11-18 IFC: 3806.2 Proponent: Kevin Scott, representing KH Scott & Associates LLC (khscottassoc@gmail.com) 2018 International Fire Code 3806.2 Hazardous materials storage and use. Storage and use of hazardous materials within control areas in new and existing laboratories equipped with an automatic sprinkler system shall be in accordance with this section and Chapters 50 through 67, as applicable. Exception: Existing laboratories in buildings equipped throughout with an automatic sprinkler s ys te m meeting requirements for laboratory suites are permitted to comply with Section 3804. This is an editorial change to correct the term for "automatic sprinkler system." This proposal is editorial. Internal ID: 2355 CCC1

CCC-F4-18 IFC: 2311.8.4.4 Proponent: Kevin Scott, representing KH Scott & Associates LLC (khscottassoc@gmail.com) 2018 International Fire Code 2311.8.4.4 Clear space. Motor vehicle repair booths shall be installed so that all parts of the booth provide are provided with ready access for cleaning. A clear area of not less than 3 feet (914 mm) wide shall be maintained on all sides of the motor vehicle repair booth. This clear area shall be kept free of any storage or combustible construction. Exceptions: 1. This requirement shall not prohibit locating a motor vehicle repair booth closer than 3 feet (914 mm) to or directly against an interior partition, wall or floor/ceiling assembly that has a fireresistance rating of not less than 1 hour, provided that the motor vehicle repair booth can be adequately maintained and cleaned. 2. This requirement shall not prohibit locating a motor vehicle repair booth closer than 3 feet (914 mm) to an exterior wall or a roof assembly, provided that the wall or roof is constructed of noncombustible material and the motor vehicle repair booth can be adequately maintained and cleaned. This revision clarifies the application of this section. The booth does not "provide" access; the booth is "provided with" access. This revision clarifies this section. This is clarification. There is no change in code requirements. Internal ID: 2332 CCC2

CCC-F8-18 IFC: 3805.2, 3805.3 Proponent: Kevin Scott, representing KH Scott & Associates LLC (khscottassoc@gmail.com) 2018 International Fire Code 3805.2 Nonsprinklered laboratories Maximum allowable quantities. The maximum allowable quantities of hazardous materials in storage and use in control areas in laboratories located in buildings not equipped throughout with an automatic sprinkler system in accordance with Section 903.3.1.1 shall be in accordance with Tables 5003.1.1(1), 5003.1.1(2) and 5003.8.3.2, except as modified by Sections 3805.2.1 and 3805.2.2. 3805.3 Restricted materials automatic Automatic f ire detection. An automatic fire detection system shall be installed in all existing laboratories in nonsprinklered buildings in accordance with this section. Detectors shall be connected to the building's fire alarm control unit where a fire alarm system is provided. Detector initiation shall activate the occupant notification system in accordance with Section 907.5 where connected to the building's fire alarm control unit. Activation of the detection system shall sound a local alarm in buildings not equipped with a fire alarm notification system. These revisions are simply to have the section title more appropriately depict the section content. All of Section 3805 addresses Nonsprinklered Laboratories, so the title of Section 3805.2 is revised to Maximum Allowable Quantities since that is what is regulated in that section. Section 3805.3 is revised by deleted the words "Restricted Materials" since they do not apply the section at all. There is no change in requirements. Internal ID: 2314 CCC3

CCC-E5-18 IBC: 1029.16.1 (IFC[BE] 1029.16.1) Proponent: Homer Maiel, representing ICC Tri-Chapter (Peninsula, East Bay, Monterey Bay) (hmaiel@gmail.com) 2018 International Building Code 1029.16.1 Discontinuous mid-aisle handrails. Where there is seating on both sides of the aisle, the mid-aisle handrails shall be discontinuous with gaps or breaks at intervals not exceeding five rows to facilitate access to seating and to permit crossing from one side of the aisle to the other. These gaps or breaks shall have a clear width of not less than 22 inches (559 mm) and not greater than 36 inches (914 mm), measured horizontally, and the mid-aisle handrail shall have rounded terminations or bends. This merely clarifies the code section. This changes simply clarifies the code provision. Internal ID: 1061 CCC4

CCC-P1-18 IPC: 705.2.1 Proponent: Michael Cudahy, representing Plastic Pipe and Fittings Association (mikec@cmservices.com) 2018 International Plumbing Code 705.2.1 Mechanical joints. Mechanical joints on drainage pipes pipe shall be made with an elastomeric seal conforming to ASTM C1173, ASTM D3212, or CSA B602. Mechanical joints shall not be installed only in underground above-ground systems unless otherwise approved. Joints shall be installed in accordance with the manufacturer's instructions. 705.10.1 Mechanical joints. Mechanical joints on drainage pipe shall be made with an elastomeric seal conforming to ASTM C1173, ASTM D3212 or CSA B602. Mechanical joints shall not be installed in above-ground systems, unless otherwise approved. Joints shall be installed in accordance with the manufacturer's instructions. Getting the ABS and PVC sections to correlate. There is slightly different language used. This wording change is essentially editorial and does not change technical requirements. Internal ID: 983 CCC5

CCC-G2-18 IBC: 202 Proponent: Michael O'Brian, Chair, representing FCAC (FCAC@iccsafe.org); Ed Kullik, Chair, representing ICC Building Code Action Committee (BCAC@iccsafe.org) 2018 International Building Code Delete without substitution: [B G ] CABLE-REST RAINED, AIR-SUPPORT ED ST RUCT URE. A structure in which the uplift is resisted by cables or webbings which are anchored to either foundations or dead men. Reinforcing cable or webbing is attached by various methods to the membrane or is an integral part of the membrane. This is not a cable-supported structure. The words CABLE-REST RAINED, AIR-SUPPORT ED ST RUCT URE are not used anywhere in IBC or IFC, except in the definition. The term air-supported is defined separately, the term cable-restrained is intuitive. The last sentence of the definition is present to make a clear distinction between cable-restrained, and cable-supported, yet the term cable-supported is also neither defined nor used. This proposal simply deletes an obsolete definition. Internal ID: 345 CCC6

CCC-FS5-18 IBC: 715 Proponent: Michael O'Brian, Chair, representing FCAC (fcac@iccsafe.org) 2018 International Building Code SECT ION 715 FIRE-RESIST ANT JOINT SYST EMS JOINT S AND VOIDS Section 715 covers more than just fire-resistant rated joint systems, it actually covers both joints and voids. This editorial title change is consistent with the concept of Section 714, entitled Penetrations. The proposal compliments a proposal which reorganizes Section 715. This proposal is submitted by the ICC Fire Code Action Committee (FCAC). The FCAC was established by the ICC Board of Directors to pursue opportunities to improve and enhance assigned International Codes with regard to fire safety and hazardous materials in new and existing buildings and facilities and the protection of life and property in wildland urban interface areas. In 2017 the Fire-CAC has held 3 open meetings. In addition, there were numerous conference calls, Regional Work Group and Task Group meetings for the current code development cycle, which included members of the committees as well as any interested parties, to discuss and debate the proposed changes. Related documentation and reports are posted on the FCAC website at: https://www.iccsafe.org/codes-tech-support/cs/firecode-action-committee-fcac/ This proposal simply changes the title of the Section. Internal ID: 324 CCC7