INSTALLATION INSTRUCTIONS FOR SERIES 9 INTERMITTENT PILOT IGNITION CONTROL

Similar documents
24 VAC Intermittent Pilot Gas Ignition Control

BGH Series Hot Surface Ignition Control

24 VAC Direct Spark Gas Ignition

Quick Reference Guide. Application. Gas Furnaces Boilers Water Heaters Commercial Cooking. Features

SERIES 35-63J APPLICATIONS FEATURES SPECIFICATIONS AGENCY CERTIFICATIONS

SERIES VAC Microprocessor-Based Intermittent Pilot Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION

SERIES VAC Microprocessor-Based Direct Spark Ignition Control with Inducer Blower Relay FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION

SERIES VAC Microprocessor-Based Direct Spark Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION. Export Information (USA)

SERIES VAC Microprocessor-Based Hot Surface Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION AGENCY CERTIFICATIONS

CAUTION WARNING. 50T Integrated Furnace Control INSTALLATION INSTRUCTIONS DESCRIPTION PRECAUTIONS

New Power Vented Rheem FVIR Tanks

MG & SG SERIES BOILERS

Technical

No. Of Ignition Trials: No. Of Re-Ignition Attempts. Reset by interrupting power for 5.0 Seconds. Diagnostic Output. Re-Ignition Limit Exceeded

Operator: Save these instructions for future use!

OWNER S MANUAL Manufactured Home Downflow Gas Furnace: MGD-B Series

50M Integrated Single or Two-Stage HSI Integrated Furnace Control Kit INSTALLATION INSTRUCTIONS

Hot Surface Ignition (HSI) System Booklet

Interrupted Ignition Series Oil Primary Control

Technical

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Ultra Low NOx PowerVent with Honeywell Electronic Control California Only

Model Universal Oil Primary Control

Operator: Save these instructions for future use!

Model 60200FR Gas Primary Control Data Sheet

50A Integrated Furnace Control

Operator: Save these instructions for future use!

Pilot Burner and Direct Spark Ignition (DSI) Applications with Flame Rectification Sensing

PDV(S,T) MODEL SERIES AND INDUCED DRAFT (D80T725, D65T625) MODEL SERIES WATER HEATERS WITH HONEYWELL INTEGRATED CONTROL SYSTEM

Technical

Operator: Save these instructions for future use!

CSD-1 COMMERCIAL BOILER CONTROLS

Operator: Save these instructions for future use!

21D83M-843 Integrated Single Stage Furnace Control Replacement Kit INSTALLATION INSTRUCTIONS

prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE TSG-SOLO-9/04

EG & PEG Series 5 EGH Series 5

A-1106 ACCESSORY KIT INSTALLATION INSTRUCTIONS IGNITION CONTROL P/N S , S , S

DOMESTIC HOT WATER Follow operational sequence

Operator: Save these instructions for future use!

Operator: Save these instructions for future use!

50M56U-843 Universal Single Stage HSI Integrated Furnace Control Kit INSTALLATION INSTRUCTIONS

50M56U-843 INSTALLER MUST READ DESCRIPTION PRECAUTIONS WARNING CAUTION

G779 Universal Intermittent Pilot Ignition Control

50A Integrated Furnace Control

ELECTRONIC FLAME SUPERVISION MULTI-BURNER

XIII Troubleshooting

Internet Version for Reference Only INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART #

prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE TSG-PRESTIGE Date revised: 11/10/08

prestige Control Application Supplement - Type 5 MCBA WARNING

TECHNICAL SUPPORT: SERVICE BULLETIN #4 (v ) AB2017 HOT SURFACE IGNITION MODULE OVERVIEW

Guardian PowerVent Training Manual. Flammable Vapor Ignition resistant (FVIR) compliant PowerVent water heater manufactured after 1 January 2006

24 VAC SYSTEM CONTROL KIT

Intermittent Pilot Ignition (IPI) and Direct Spark Ignition (DSI) Applications with Flame Current Probes

Aqua Balance. AquaBalance TM CONTROL MODULE QUICK START GUIDE LEGEND

Instructions. Easy-wire terminal strip Microprocessor-operated. Easy remote sense. Self-checking program. Diagnostic/status LED s

95M-200. Gas-Fired Direct Vent Modulating Hot Water Boiler. Control Manual And Troubleshooting Guide. P/N , Rev.

BasicTroubleshooting Information and Guidelines

Flame Safeguard Fault Code Diagnostics

2017 OUTDOOR CONTROL SYSTEM WEATHER BEATER ELECTRONIC CONTROL SYSTEM

Technical Manual MAY 2008 Edition

7800 SERIES RM7888A Relay Module

Figure 10 or Figure 6

IFT-RC150 IntelliFire Touch Remote Control Installation Instructions

Q - Series Boiler. Troubleshooting Manual

LGB Gas fired boiler

7800 SERIES RM7888A Relay Module

R7910A SOLA (Hydronic Control) and R7911 SOLA (Steam Control) Systems

OBSOLETE. Y8610U Intermittent Pilot Retrofit Kit GENERAL FEATURES PRODUCT DATA. Contents

Y8610U Intermittent Pilot Retrofit Kit

S9360A, S9361A, S9380A, S9381A Integrated Boiler Controllers

GAS FIRED COMMERCIAL COPPER BOILERS

TO DO IF YOU SMELL GAS

40 Residential Gas Furnace Operation

Heating Basics Gas Valve Systems

Technical

S9361A, S9381A Integrated Boiler Controllers

Y8610U Intermittent Pilot Retrofit Kit

R7910A SOLA (Hydronic Control) and R7911 SOLA (Steam Control) Systems

DC50X2 Models 50 Pound Stacked Commercial Dryer. Troubleshooting,Fault Codes, and Schematics. Starting serial number Part # /13

BC-R10 Series. Burner Controllers

Parts Manual. Gas Floor Type Convection Steamer. Series: SteamCraft Model 24CGA East 179 th Street Cleveland, Ohio 44110

S9360, S9361, S9370, S9371 Integrated Boiler Controllers

AXIAL HEATER TROUBLE SHOOTING GUIDE. Models: AX24 N/PV, AX24 N/PV LT, AX24 LP AX26 N/PV, AX26 N/PV LT, AX26 LP AX28 N/PV, AX28 N/PV NT, AX28 LP

STEAMPAK Series BurnerPAK BMS Burner Management Systems

Instructions R8471J Gas Controller for use with Model OPECL Open Path Eclipse IR Gas Detector 1.1 1/

COMMERCIAL 24 VOLT FLUE DAMPER

7800 SERIES: EC7895A,C; RM7895A,B,C,D; RM7896A,B,C,D RM7897A,C and RM7898A Relay Modules

Power Flame Incorporated

Technical

7800 SERIES Relay Modules

EGH Series 5. Control Supplement. EGH-105 to EGH-125 Natural gas CSD-1 control system

Each burner shall be equipped with a Micro-Processor Based Burner Management Flame Safeguard and Parallel Positioning Control System.

COMMERCIAL 24 VOLT FLUE DAMPER

WARNING WARNING TROUBLESHOOTING GUIDE INTEGRATED FURNACE CONTROL MODULE

DSGH. Radiation-Based Detector with GEN2000 Electronics for Density Measurement QUICK REFERENCE GUIDE

USER'S INFORMATION MANUAL

SERVICE MANUAL. PV Series. Power Vent Gas Water Heaters. Troubleshooting Guide and Instructions for Service. Models Covered by This Manual:

prestige Control Application Supplement - Type 5 MCBA WARNING

24 VAC SYSTEM CONTROL KIT

7800 SERIES EC7890A,B; RM7890A,B,C Relay Module

100T399-SOLA SUPPLEMENT TO INSTALLATION & OPERATION MANUAL INCLUDED WITH WATER HEATER (SERIAL NUMBERS BEGINNING LK AND LATER)

Transcription:

INSTALLATION INSTRUCTIONS FOR SERIES 9 INTERMITTENT PILOT IGNITION CONTROL Figure 1 Series 9 Intermittent Pilot Ignition Control Application The Series 9 Intermittent Pilot Ignition Control is a microprocessor based ignition control. The microprocessor provides reliable software control of all timings and operates a diagnostic led. It is designed for indirect burner ignition and supervision and can be used with all gases. It provides ignition sequence, flame monitoring, and safety shutout for intermittent pilot boilers, furnaces and other heating appliances. Specifications see part number matrix on page 2 Electrical ratings: Voltage 24VAC (+/- 20%) 50/60 Hz Pilot valve 2A maximum Main valve 5A maximum Alarm output 1A maximum Operating current 0.2A Wiring connections 1/4 male spade Environmental: -40 to +80 degrees C (-40 to +176 F) Waiting time; 0 to 99 (1 second minimum diagnostic) Safety time: 4 to 125 seconds (see table) Flame loss response: spark restoration or recycling Flame loss waiting time: for recycle 1 to 99 seconds Retries: 1 to 9 tries or continuous retry Inter-Purge time: 1 to 99 seconds or 1 to 99 minutes Flame failure response time: 1 second maximum Minimum flame current required: 0.15 microamperes Type of gas: Recommended Spark Gap: Pilot burner rating: Main burner rating: Natural, LP, or manufactured 5 mm, 0.2 inches maximum 1,500 Btu/hr. maximum 400,000 Btu/hr. maximum Copyright 2010 Capable Controls Inc. 1 PRELIMINARY

Model Number Matrix Series 9 CE Ignition Controls Table 1 Hardware Models 9 Always 9 for series 9 controls 0 Intermittent Pilot Int.Sense Volatile 1 Intermittent Pilot Ext.Sense Volatile A 2 Intermittent Pilot Univ.Sense Volatile Hardware Model see table 1 8 Intermittent Pilot Int.Sense n-volatile B C D E F G H J K L M N WARNING: Be sure this control is suitable to replace existing control. The control replaces many existing intermittent pilot ignition controls with flame rectification flame sense and spark ignition made by various manufacturers. When replacing an existing control be sure characteristics match. Special Options see te 1 0 = ne, 1 = Flame Stabilization 2 = Quick Start, 3 = Both Number of Trials 0 = Continuous Retry Lockout or select 1 to 9 Inter-Waiting Time Between Trials 001 to 900 sec in 1 sec steps 901 to 999 = 1 to 99 min in 1 min steps Flame Loss Response See te 2 If 00 Uses Spark Restoration If 01 to 99 uses Recycle 1 to 99 sec Flame Loss Waiting Time Waiting Time Before Valve On 00 to 99 sec in 1 sec steps Safety Time 000 = Infinite Lockout 004 to 124 sec in 4 sec steps 005 to 125 sec in 5 sec steps and 006 seconds 9 Intermittent Pilot Ext.Sense n-volatile A Intermittent Pilot Univ.Sense n-volatile Hardware Flame Sense Options Int. Internal through spark wire only Ext. External with probe only Univ. Universal Internal or External Jumper selected Hardware Lockout options Volatile turning off power resets lockout n-volatile must operate external reset switch to reset lockout te 1 Special Options Flame stabilization is only for controls with flame loss waiting time (G-H) 1 sec or more. If flame is lost within 5 sec use spark restoration. If flame lost after 5 sec use recycling. See note 2 Quick Start is only for controls with external sense only. Can turn on main valve in 1 sec instead of 4 or 5 sec. te 2 Flame Loss Response With Spark Restoration main valve turns off pilot valve stays on and spark and new cycle start immediately. With Recycing pilot and main valve turn off and new cycle starts after Flame Loss Waiting Time (G-H). O Special Customer Options Copyright 2010 Capable Controls Inc. 2 PRELIMINARY

WARNING Fire or explosion hazard. Follow these instructions carefully. Control must only be installed by a qualified service technician. Warning: This control is approved for use with only noise suppression (resistive) spark wires. If application has copper wire it must be replaced. Control must be protected from water dripping or condensing on it. A wet control may malfunction causing hazardous conditions. Appliance must be inspected for any hazardous conditions before starting up. Must be checked for proper wiring, gas leaks, water leaks, burners must be clean and vents clear. Replacement instructions Mounting the new control Before replacing existing control turn off power to the appliance being serviced. Mark wires to existing control. Disconnect wires and remove existing control. The control is not position sensitive. It may be mounted horizontally or vertically with two #6 sheet metal or machine screws 4.85 1.50 LED 4.25 2.625 MV (VALVE) PV 1 2 3 (BURNER) 4 24V 5 6 7 8 RESET 9 INTERN 10 SPARK 11 3.15 HOLES FOR 2 3mm OR #6 SCREWS` Figure 2 Mounting Dimensions Copyright 2010 Capable Controls Inc. 3 PRELIMINARY

Wiring Control Power must be provided from a properly sized 24 volt class 2 transformer. All wiring must be done in accordance with both local and national electrical code. All wiring and initial operation must be performed by a qualified service technician. Controls with universal flame sense are supplied with a jumper wire between and INTERN terminals and is ready for internal (one rod) flame sense. With the jumper in, flame is sensed through the high voltage spark wire. For external (two rod) flame sense the jumper must be removed and discarded and the sense electrode wired to terminal. Spark Cable Cable must be noise suppression (resistive) type rated for at least 15kV and must not be in continuous contact with a metal surface. If separate flame sense probe is used, the sense wire must be separated from the high voltage wire by a minimum of 1/4. Warning: This control is approved for use with only noise suppression (resistive) spark wires. If application has copper cable it must be replaced. The schematics in Figures 3, 4, 5 and 6 show typical wiring hookups for the control. Startup and Checkout WARNING: The control module can not be serviced by user. If any faults are detected control module must be replaced. 1. Before starting the appliance perform a safety inspection of piping, burners and venting. Check for water leaks, etc. Check all wiring for proper connections. Be sure system is properly grounded including ground connection to pilot burner. 2. With gas shut off, turn on power to appliance with thermostat contacts closed. Verify led on module flashes rapidly and that there is a good spark at the pilot burner. If spark is not present see troubleshooting flow chart figure 8. 3. Turn off power to appliance and turn on gas shutoff valves. Check for gas leaks using a soap solution or gas detector. 4. Turn on power to appliance with thermostat contacts closed. Verify that spark lights pilot burner followed by main burner. If there are any problems shut down the appliance and refer to the troubleshooting flow charts figures 7 and 8. 5. Verify normal operation with both burners on for at least 5 minutes. Check for any gas leaks after the valves. 6. Cycle thermostat open/closed and verify proper ignition sequence at least 5 times. Copyright 2010 Capable Controls Inc. 4 PRELIMINARY

*RESET SWITCH ONLY FOR N-VOLATILE LOCKOUT MODEL 98 XX 90 XX OR 98 XX INTERNAL *RESET SWITCH ONLY FOR N-VOLATILE LOCKOUT MODEL 99 XX 91 XX OR 99 XX EXTERNAL BURNER Figure 3 Wiring for Models 90_XX AND 98_XX Internal Flame Sense 4 THERMOSTAT RESET* MAIN VALVE PILOT BURNER 24V 1 M.V. 2 DUAL VALVE IS OPTIONAL 24V 1A MAX. 3 4 5 P.V. BURNER MUST BE EARTH GROUNDED 6 7 8 HIGH TEMP LIMIT RESISTIVE ISE SUPPRESSION WIRE RESET INTERN SPARK MAIN VALVE PILOT 24VAC FROM TRANSFORMER CLASS 2 9 10 PILOT BURNER 11 1 2 3 THERMOSTAT 24V RESET INTERN SPARK M.V. P.V. DUAL VALVE 24V 1A MAX. IS OPTIONAL BURNER MUST BE EARTH GROUNDED 5 6 7 Figure 4 Wiring for Models 91_XX AND 99_XX External Flame Sense 8 9 10 11 HIGH TEMP LIMIT RESET* FLAME SENSOR 24VAC FROM TRANSFORMER CLASS 2 PILOT BURNER Copyright 2010 Capable Controls Inc. 5 PRELIMINARY

LOCKOUT MODEL 9A XX *RESET SWITCH ONLY FOR N-VOLATILE USED FOR INTERNAL 92 XX OR 9A XX UNIVERSAL *RESET SWITCH ONLY FOR N-VOLATILE LOCKOUT MODEL 9A XX USED FOR EXTERNAL 92 XX OR 9A XX UNIVERSAL BURNER 2 Univeral Flame Sense used for Internal Sense Figure 5 Wiring for Models 92_XX AND 9A_XX 4 RESET* MAIN VALVE PILOT BURNER 24V 1 M.V. 3 DUAL VALVE 24V 1A MAX. IS OPTIONAL 4 BURNER MUST BE EARTH GROUNDED 5 6 7 8 HIGH THERMOSTAT P.V. TEMP LIMIT RESISTIVE ISE SUPPRESSION WIRE RESET INTERN SPARK MAIN VALVE PILOT 24V RESET INTERN 24VAC FROM CLASS 2 TRANSFORMER 9 10 11 JUMPER WIRE SUPPLIED WITH CONTROL PILOT BURNER 1 M.V. 2 3 P.V. DUAL VALVE IS OPTIONAL 24V 1A MAX. BURNER MUST BE EARTH GROUNDED 5 6 JUMPER REMOVE Universal Sense used for External Sense Figure 6 Wiring for Models 92_XX AND 9A_XX 7 8 9 10 HIGH TEMP LIMIT THERMOSTAT RESET* FLAME SENSOR SPARK 24VAC FROM CLASS 2 TRANSFORMER PILOT BURNER 11 Copyright 2010 Capable Controls Inc. 6 PRELIMINARY

te: Letters and numbers in parenthesis refer to matrix on page 2. Sequence of Operation Basic Control Software (B = 0) Heating cycle starts when call for heat from thermostat supplies 24VAC to 24V terminal. Control will perform a 1 second maximum diagnostic. If waiting time is specified (J-K = 02 to 99) the control will wait for the specified time with led blinking orange once a second. Then the spark will start and pilot valve will turn on starting safety time. On controls with internal sense it takes time for the flame sense to recover. Because of this the controls normally work in 4, 5 or 6 second cycles based on the safety time. The control rapidly flashes red led while generating sparks for 2.75, 3.75 or 4.75 seconds. Then turns off spark and led, Then waits 1.25 seconds before checking for flame. This cycle will repeat until pilot flame is detected or safety time is over. If pilot flame is not detected during safety time limit, the pilot valve will be shut off. If 1 try is specified (C = 1) or number of tries has been completed control will go to lockout. If more than 1 try (C = 2 to 9) is specified The control will wait for inter-waiting time (D-E-F 1 to 99 sec or 1-99 min) while blinking the led orange at the end of each 5 seconds. When the inter-waiting time is over a new ignition sequence will start. When pilot flame is detected, the spark will stop, main valve will turn on and led will stay on green continuously. The control will remain in this state until pilot flame is lost or thermostat opens. If pilot flame is lost, and spark restoration is selected (G-H = 00), the main valve turns off and pilot valve stays on. Spark starts immediately and new safety time starts. If pilot flame is lost, and recycle is selected (G-H = 01 to 99), the main and pilot valves turn off. Control waits flame loss waiting time (G-H) blinking orange led once a second. Then spark and pilot valve will turn on starting new safety time. Flame Stabilization Option (B = 1 or 3) Flame stabilization is only used on controls with flame loss waiting time (G-H 1 to 99). It is intended for applications with unstable pilot flame. If flame is lost after being on less than 5 seconds, the control uses spark restoration and turns off main valve and starts spark immediately. If flame is lost after 5 seconds, the control turns off pilot and main valves and waits flame loss waiting time (G-H) before starting new ignition cycle. Quick Start Option (B = 2 or 3) Quick start is only available for controls with external sense only hardware (A = 1 or 9). External sense controls do not have the flame sense while sparking problem. Quick start controls spark for 0.5 seconds. Turn off spark and check for flame immediately. Quick start controls can turn on main valve within 1 second. Copyright 2010 Capable Controls Inc. 7 PRELIMINARY

SAFETY TIME LOOP RUN MODE LOOP Thermostat closes Call for heat Diagnostic tests Send model number on led Turn safety relay on Total 1 sec for diagnostic* INTERMITTENT PILOT IGNITION CONTROL OPERATIONAL FLOW CHART Wait 0.5 seconds checking memory and relay driver circuits* Waiting time J-K zero? Verify flame is off if on wait up to 0.75 sec to go off* Blink orange led once a sec for waiting time minus 1 seconds Verify flame off* Flame on? Flame stabilization? Turn on spark & pilot gas valve relay Start safety time L-M-N Wait 0.25 sec Flame on? Set spark on time 0.5S for quick start, 2.75S for 4S, 3.75S for 5 sec or 4.75S for 6S. if not quick start and had flame flag is set subtract 0.5S Spark for set time blinking red led rapidly, turn spark off, if not quick start wait 1.25 sec clear had flame flag SAFETY TIME OVER Flame on? Safety time complete? Turn off plot gas valve relay Set had flame flag Wait 0.5 sec Flame on? Turn on green led & main gas valve relay Reset trial count SPARK RESTORATION RELIGHT Start spark Wait 0.25 sec FLAME LOST Turn off main gas valve relay and led Spark restoration? Flame stab & less than 5 sec RECYCLING Turn off pilot gas valve relay wait flame loss waiting time G-H blinking orange once a second Multiple trials? Trials over Delay inter-waiting time D-E-F blinking orange every 5 sec LOCKOUT TRY AGAIN LOCKOUT LOCKOUT LOOP If timeout or fault detected lockout loop turns off all relays and spark. Waits blinking error code on led until power off for volatile lockout or reset switch for non-volatile lockout. Blocks marked with * go to lockout if fault detected. Control constantly monitors relay circuits and memory and will lockout if fault detected. Figure 7 Operational Flow Chart Copyright 2010 Capable Controls Inc. 8 PRELIMINARY

Alarm output The alarm out put uses the normally closed contact on the safety relay. It will turn on if flame fails to light in the safety time or a fault is detected in the control. The output will also be on for a half second on power up until safety relay turns on. Led Indications during normal operation orange once a second Waiting Time rapid red flashing Safety Time sparking steady green Running position flame on orange once every 5 seconds Inter-Waiting Time between trials orange once a second Flame Loss Waiting Time Led error indications If the control module internal diagnostics detect a fault it will go to lockout. Spark and both valves will be turned off. The led will flash the error code red.25 sec on and.25 sec off for the error code with then blink green per error code. Will turn off 1 second between codes. The control will remain in this condition until power is removed by turning off call for heat. te the control contains 2 micros (microprocessors). The safety micro controls a safety relay that enables power to the valves. It monitors operation of master micro and will turn off safety relay if it detects a problem. The master micro controls the spark, flame sense and pilot and main valve relays. Codes other than 1-0 for no flame within safety time may indicate a problem with the control. Recycle control and if error repeats control must be replaced. Error codes are: red green 1 0 Flame did not light in safety time 1 1 Flame sense circuit stuck on 1 2 Safety micro fault 1 3 Line frequency or micro clock error 2 1 Pilot valve relay transistor driver circuit fault 2 2 Pilot valve relay contact fault 2 3 Main valve relay transistor driver circuit fault 2 4 Main valve relay contact fault The following are software faults unlikely to occur 3 0 Main micro code memory error 3 1 Main micro timing parameter storage error 3 2 Main micro RAM (random access memory) error during operation 3 3 Main micro RAM (random access memory) error on power up 3 4 Main micro program flow error 4 0 Timing parameters in safety micro do not match master micro Copyright 2010 Capable Controls Inc. 9 PRELIMINARY

Turn on power and gas close thermostat contacts INTERMITTENT PILOT IGNITION CONTROL MODULE TROUBLE SHOOTING FLOW CHART Led did not light & no spark? Led blinks red/grn slowly? Diagnostic error see error code list. Replace Module 24V between 24V and terminals? Replace Module Check and transformer, thermostat and wiring. Repair or replace as needed. Led blinks red rapidly but no spark? Spark wire and electrode Ok? Replace Module Replace spark wire or electrode Pilot flame does not light? 24V between PV and terminals? Replace Module Gas at Pilot Burner? Adjust or replace spark electrode and/or pilot burner. Check shutoff valves are on. Check wiring to pilot valve. Check orfice and tubing are clear. If all Ok replace pilot valve. Pilot lights but keeps sparking? Pilot flame in contact with spark or sense electrode? Check burner orifice. Adjust pilot flame size or electrode position. Pilot is lit continued on next page External flame sense? Replace Module Check wiring electrode to terminal. If Ok replace Module Figure 8 Troubleshooting Flow Chart Part 1 Copyright 2010 Capable Controls Inc. 10 PRELIMINARY

continued from previous page Pilot is lit INTERMITTENT PILOT IGNITION CONTROL MODULE TROUBLE SHOOTING FLOW CHART Main burner failed to turn on? 24V between MV and MV/PV terminals? Replace Module Gas at main burner? Adjust pilot flame size and position, or replace pilot burner or main burner. Check shutoff valves are on. Check wiring to main valve. Check tubing is clear. If all Ok replace main valve. After main is lit, do valves turn off and start new cycle? Pilot flame in contact with spark or sense electrode? Adjust pilot flame size or electrode position. Control is operating normally External flame sense? Replace Module Check wiring to terminal. If Ok repace Module Figure 9 Troubleshooting Flow Chart Part 2 Copyright 2010 Capable Controls Inc. 11 PRELIMINARY

LED INDICATIONS Led Indications During rmal Operation Orange once a second Waiting Time Red rapid flashing Safety Time Spark On Steady green Running Position Flame On Orange once every 5 seconds Inter-Waiting Time Between Cycles Orange once a second Flame Loss Waiting Time Led Error Indications Red Green Error 1 0 Flame did not light in safety time 1 1 Flame sense circuit stuck on 1 2 Safety micro fault 1 3 Line frequency or micro clock error 2 1 Pilot valve relay transistor driver fault 2 2 Pilot valve relay contact fault 2 3 Main valve relay transistor driver fault 2 4 Main valve relay contact fault More than 2 red blinks indicate micro memory or software fault Copyright 2010 Capable Controls Inc. 12 PRELIMINARY