MAGISTER. Compact and attractive design Energy savings with EC motor and self-regulating control. Easy to install. Use. Chilled water operation

Similar documents
50CO. Close Control Unit. Wide range of chilled water cabinets. Compact and attractive design. EC motor for energy savings. Auto-adaptive control

Vertical self-contained air conditioner

EXPAIR. Use. Precision air handling cabinets. Reducted footprint Dual-wall construction

FLOWAY. Floway Range. The dual-flow air handling unit with heat recovery guaranteeing an Economical and Durable solution. use.

Precision air handling cabinets Ciatronic MICRO/EXPAIR

CLIMACIAT AIR COMPACT

Precision air-handling cabinets. CIATRONIC System Ultimate precision air-conditioning NA C

VEXTRA. acoustic comfort Saves up to. 40% floor space. Use. Range. Description. Drycoolers. Slim design and. Capacity up to kw.

GeoCIAT Modular. Components. Heat pump Heating only, Glycol/water mix/water. Refrigerant and hydraulic module diagram. HomeConnect control.

CIATCOOLER LJA. Chilled water production units USE. Attractive design, Compact and quiet

OPERA MORE. Use. Range. Drycoolers Air-cooled condensers. for LESS. Capacity: up to 1100 kw. Water misting. Free cooling

Centrifugal air heaters hot water or electrical supply

39HX. High-efficiency dual-flow air handling unit PRODUCT SELECTION DATA. Plug & play unit (built-in control) Class A+ across entire range

Compact and silent Scroll compressors All-season operation

HYDROCIAT LW R407C. Water cooled chillers USE RANGE

NA B MAGISTER. Instruction manual

AQUACIAT. Water chillers. Free cooling modules for AQUACIAT2 700V to 1100V AQUACIAT POWER 1200V to 1800V USE RANGE FREE COOLING

ECOCIAT. Domestic hot water heat recovery unit. Use. Range

NA G µair CONNECT 2

CLIMACIAT. air HanDLIng UnIT: CLIMaCIaT. Air handling unit

DRYPACK. Protecting installations Energy optimisation. Operating principle. Description. Biogas dehumidification system. Improved profitability.

Split inverter air-to-water heat pump CERTIFIED BY CERTITA. option 30/35-40/45

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

V3000 KNX. KNX PID control system on water GENERAL DESCRIPTION

AGEO CALEO. Water-to-water high temperature heat pumps USE RANGE DESCRIPTION. Designed to replace a conventional boiler and produce domestic hot water

> Refrigerant R-410A. Uniflair LE TDER-TUER kW. Energy-saving units with backward-curved fans. Perimeter cooling for medium/large data center

NA B AIR COMPACT. Instruction manual

HOT AIR GENERATOR WITH GAS BURNER NA11.45 A GGS. Installation Operation Commissioning Maintenance

The refrigerant circuit was studied in detail. Each step is verified, ensuring that each unit is perfectly leak-tight.

Next P kw COOLING 5 93 kw HEATING. technicalcatalogue. Heat pump air conditioners with upflow air delivery T_NXTP_0411_GB

NEXT EVO DXR410A NEXT EVO DX NEW SOFTWARE. rcgroupairconditioning

AIRSYS-P-SC-CHILLROW-E1503V01.1 CHILLROW. Row Cooling Precision Air Conditioner. Cooling Capacity: 26.2kW~68.6kW

CHG AIR COOLED WATER CHILLER WITH CONDENSATION BY HELICOIDAL AIR 8 to 17 kw

COOLROW Close control air conditioners for In-Row installation Cooling Capacity: kw

DYNACIAT POWER. High energy efficiency Compact and quiet

AQUACIAT. Inverter Heat pump USE RANGE GRAND INVERTER

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers

PHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER 9 to 18 KW

Next MTR kw. technicalcatalogue. Air conditioners for Metrology Labs with upflow air delivery T_NXTMTR_0511_GB

next p dw next p dw rcgroupairconditioning

DYNACIAT LG. Use. Range. Water chillers Heat pump. DYNACIAT LGN series. DYNACIAT LG series. Hydraulic module

CWX 3 - CWX 5 CASSETTE TYPE TERMINAL UNIT. Cooling

CWX 6 - CWX 8 - CWX 10 CASSETTE TYPE TERMINAL UNIT

Aquaciat Free cooling

HRV-IP. Ceiling Type Heat Pump Heat Recovery Unit

Blower-YEFB-020-3R-1maxVel

NEXT DL NEXT DL. rcgroupairconditioning

Roof top SPACE RPC 450Z R407C M011

condenciat cl Condensing units Outdoor condensing unit Variable speed propeller fan Use Description for direct expansion applications

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1

UNITES TERMINALES ET MINI CTA FIDJI

Roof top SPACE RPC 315Z R407C MA00

CONDENCIAT CD. Condensing units. Quiet operation Low speed fans All year round operation USE. Cooling capacity : 25 to 165 kw.

AQUACIAT LD ILD. Use. Range. Water chillers Heat pump. AQUACIAT LD series. AQUACIAT ILD series. Heat recovery. Cooling only. Cooling and heating

Chilled Water Precision Air Conditioner for Critical Application

Air treatment units 0932EN October 2017 Dehumidifier unit for radiant systems Flush-mounting installation in false ceilings

ED.X F Kc DIRECT EXPANSION CLOSE CONTROL UNITS WITH REMOTE CONDENSERS AND ADDITIONAL CHILLED WATER FREE COOLING COIL

TECAM S.A. harmony. 5PZA Direct Expansion. Air Conditioning Equipment Manufacturer. R-410A PRECISION UNIT 2 Ton 6 Ton / 60 Hz. Tecnología Ambiental

New HEE control. n Room thermostat for THREE-PHASE or SINGLE-PHASE installation

DYNACIAT ILG. Use. Description. Heat pumps

CORRIGENDUM No.l to the Tender Dossier. Reconstruction of Judicial Academy Building in Belgrade Location - Republic of Serbia

AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES

High temperature air-to-water heat pumps

Refrigerant R407C CW-AR. 2.4 to 3.1kW. Water Source Heat Pumps - Vertical Mounting Version Models 07 to to 2.7kW

Homepage > Products > Decentralised ventilation systems > Vertical units > Type FSL-V-ZAB/SEK FSL-V-ZAB/SEK

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

KPSW CONSOLE TERMINAL UNIT

AIR COMPACT. Air handling units. Ultra high performance USE RANGE DESCRIPTION

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw

YORK Close Control units

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ

next evo cw next evo cw rcgroupairconditioning

K Series Modular air conditioners. With direct expansion coil With chilled water coil

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

Большая библиотека технической документации каталоги, инструкции, сервисные мануалы, схемы.

Flexible & Innovative. Cooling Solutions

GHE GHE. Dehumidifiers for radiant cooling systems with heat recovery VERSIONS ACCESSORIES

GEA Ultra-Denco. GEA Heat Exchangers / HVAC Systems. Close Climate Control for IT Environments. Reliability with low power consumpstion

next DX.U.S* 052.Z2.H6.DC

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers

Split-system cooling units and heat pumps SERIES. Outdoor unit. Indoor unit OPERATING LIMITS. Inlet air conditions Cooling Heating.

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

H3/V3 Series Horizontal and Vertical Indoor Air Handling Units. Engineering Catalog

DATATECH. Precision air conditioners for technological environments 6 220

TECHNICAL MANUAL YEFB HIGH PRESSURE DUCTED UNIT

EASY_R R407C. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans. 5,2 41,5 kw T_ESY_R_0508_GB

RAS Kp AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 LIQUID CHILLERS - AIR COOLED AIR

YORK YC-P Series Close Control Air Conditioners

N M AirControl AHU. Control manual

AIRSYS-P-SC-MOBILECOOL-INDOOR-E1507V01.2 MOBILECOOL-INDOOR. Air Conditioner for Telecommunication Base Station. Cooling Capacity: 3.4~13.

GHE Dehumidifiers for radiant cooling systems with heat recovery

THE CARRIER COMFORT LINE

CONDAIR RS. Resistive steam humidifier With advanced scale management. Humidification and Evaporative Cooling

Precision Air Conditioner For Critical Application

AIR COOLED FREE-COOLING CHILLERS WITH SCROLL COMPRESSORS AND AXIAL FANS

york airside products Tailored air conditioning solutions Introducing the YORK YPRE range of custom air-to-air packaged roof top units

42AM. Air heaters PRODUCT SELECTION DATA

Transcription:

Extensive range of chilled water or direct expansion systems Compact and attractive design Energy savings with EC motor and self-regulating control Easy to install Cooling capacity: 10 to 116 k Air flow rates: 3 000 to 27 500 m 3 /h 410A ErP READY Use Close control unit specially designed for spaces with high heat loads or sensitive rooms (data centres, computer rooms, switch rooms, etc.). Its built-in technologies - self-regulating control that adjusts to room loads and electronically commutated motor - keep its energy consumption down. Magister boasts a sleek design that blends into any space. Chilled water operation Magister C (Chilled ater) Vertical chilled-water air handling unit. The fan also has a ModBus card which allows faults and settings such as the actual power input, current, rotation speed, etc. to be transmitted. Direct expansion operation Magister DXA - Direct expansion Vertical self-contained unit with air condensation unit (R410A fluid). heat pumps - AIR CONDITIONING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 14.611 A 1

UNDER configuration OVER configuration Air discharge into raised flooring Front return air (except C 115) Bottom return air (except C 115 - DXA) Quick selection guide (except C 115) C range - Chilled ater C C 40 C 53 C 78 C 100 C 115 Air flow rates (m 3 Nominal(1) Maximum(2) Nominal(1) Maximum(2) Nominal(1) Maximum(2) Nominal(1) Maximum(2) Nominal(1) Maximum(2) /h) 10 000 13 300 13 300 13 300 18 800 20 500 24 500 27 000 27 000 27 500 Sensible cooling capacity (k) 40 45 55 53 78 78 100 100 127 130 Nominal capacity (k) 3.7 3.7 7.1 7.1 9.6 Nominal current (A) 6.4 6.4 11.8 11.8 15.7 (1) Conditions: return air at 24 C with 45% RH ater temperature range of 7/12 C * Excluding optional electric heater and humidifier (2) Conditions: return air at 26 C with 40% (RH) ater temperature range of 10/15 C * Excluding optional electric heater and humidifier Magister DXA - Direct expansion DXA 59 DXA 65 DXA 70 DXA 85 Outdoor unit no./type 2 x CD100 2xCD 120 2 x CD120 2 x CD 150 Air flow in (m 3 ) 15 000 15 700 18 500 21 000 Total cooling capacity (k) 60 67 72 86 Characteristics: Total cooling capacity, air 24 C 45%, 32 C outdoor Correction factors 30 C 32 C 35 C 40 C 24 C / 50% 1.02 1 0.98 0.93 26 C / 50% 1.06 1.04 1.02 0.96 Correction factors to apply to the cooling capacity based on the outdoor temperature and the return air conditions. Options (available capacities) Electric heaters Units C C 40 C 53 C 78 C 100 C 115 DXA 59 DXA65 DXA70 DXA85 DXA Capacity (K) 12 18 24 33.6 32.4 43.2 18 18 24 24 Total current (A) 17.3 26 34.7 48.6 46.77 62.35 26 26 34.7 34.7 Hot water coil (C only) C C 40 C 53 C 78 C 100 C 115 Air flow (m 3 Nominal Maximum Nominal Maximum Nominal Maximum Nominal Maximum Nominal Maximum /h) 10 000 13 300 13 300 13 300 18 800 20 500 24 500 27 000 27 000 27 500 Heating capacity (k)* 36 40 44 44 63 66 71 73 Heating capacity (k)** 18 21 23 23 33 34 37 38 * 17 C - 80/60 C ** 17 C - 45/40 C 2 heat pumps - AIR CONDITIONING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 14.611 A

Humidifier Model C 40 to C 115 DXA59 to DXA85 Ventilation Steam flow rate (kg/h) 8 Electrical capacity (k) 6 Current (A) 8.7 Units Air flow rates (m 3 /h) Operating pressure max. with G4 filter (Pa) Operating pressure max. with F7 filter (Pa) C C 40 C 53 C 78 C 100 C 115 DXA59 DXA65 DXA 70 DXA 85 Nominal Maximum Nominal Maximum Nominal Maximum Nominal Maximum Nominal Maximum 15 000 15 700 18 500 21 000 10 000 13 300 13 300 13 300 18 800 20 500 24 500 27 000 27 000 27 500 400 171 229 229 400 400 343 157 400 400 400 400 400 355 400 60 140 140 400 400 261 68 400 385 400 400 400 345 DXA Description Casing Double-wall construction (M0/A1 fire resistance). Detachable pre-coated grey (RAL 7035 and RAL 7024) panels. - 0.8mm painted pre-coated exterior panel. - 25 mm mineral wool insulation. - 0.8 mm galvanised interior panels. Filtration Filter cells: G4, F7. DXA: Filter cells tightly compressed against counterframe by a gasket to ensure a leaktight seal. C: Holds filter cells pressed against the counter frame with the gasket directly on the filter cells. Filter restriction monitored by an analogue sensor. Restriction values displayed by controller. Cooling coil section Copper tubes, aluminium fins. Aluminium or stainless steel condensate drain pan. Stainless steel coil casings (option). Fitted and connected two-way or three-way control valve. Outdoor unit (DXA model) CONDENCIAT CD air condensation unit. Power supply: Three-phase 400V / 50Hz + earth T. SCROLL heat compressor. HP safety pressure switch. 2-speed IP54 motor. Coil protection grille. Accessories (options) Free cooling box. Support base for delivering supply air into a raised floor. Cased base with grille or damper. Supply plenum. Motorised intake damper. Fire thermostat. Supply air low-limit sensor. LON gateway. Management of pressure in raised floor (only for C). Changeover thermostat (only for C). Ventilation section Plug fan coupled with an induction motor or an electronically commutated (EC) motor. EC motor: fan speed adjusted by a potentiometer or automatically by the controller based on room loads (system air control). The fan* also has a ModBus card which allows faults and settings such as the actual power input, current, rotation speed, etc. to be transmitted. *C only Electrics box Electrical power and control box consisting of: - Power supply (three phase, 400 V, earth). - Main disconnect switch. - Protected transformer (three phase, 400 V, 50 Hz). - all electrical components protected and controlled by a circuit breaker and contact switch. - CIAT µair CONNECT2 controller. - Monitoring of return air dry-bulb temperature. - monitoring of return air humidity during supply or dehumidification. - Options: water leak detection - Remote control and fault summary contact. heat pumps - AIR CONDITIONING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 14.611 A 3

Options Electric heater Controlled by fan. 2-stage or TRIAC control. High-limit safety thermostat with automatic and manual reset. Hot water coil (C model) One-row coil made of copper tubes with aluminium fins. Two or four-way modulating valve fitted and connected. Humidifier Immersed-electrode humidifier with CPY control board to relay humidifier information directly to the CIAT µair CONNECT2 PLC: - Stainless steel, large surface area electrodes. - Flow rates of 8 kg/h, depending on the model. - Steam cylinder in a single easy to remove component. - Drain pump and filling solenoid valve. - Electronic control panel. - Distributor pipe. For use with city water only (with a conductivity of between 350 and 1250 µs and a hardness of between 15 and 30 F). Do not use deionised or softened water. Control Controlling and monitoring the units : CIAT mair CONNECT2 control system - 160-character display shows operating instructions, operating states, faults and solutions. Configurable controller. - Two fault levels. - Monitoring of running times. 1 2 3 Reset - RS485 output with a Jbus / ModBus protocol. 4 5 6 7 8 9 - Master/slave operation possible.. Enter 0 - C - LON gateway (optional). - Management of pressure in raised floor (optional). - Changeover thermostat (optional). - Bus management between the centrifugal plug fan and the mair CONNECT2 controller. - transmits fan faults and settings such as the actual power input, current, rotation speed, etc. to the controller (for C only) Dimensions C 40-53 UNDER 1 OVER 3 OVER 5 C H L 40 1190 1990 890 53 1520 4 heat pumps - AIR CONDITIONING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 14.611 A

Precision air handling cabinets C 78-100 OVER 3 UNDER 1 C H 78 L C 115 2070 1990 100 OVER 5 890 2620 DXA 59-65 - 70-85 UNDER 1 UNDER 1 DXA 59-65 70-85 H 1990 heat pumps - AIR CONDITIONING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 14.611 A OVER 3 L 2070 2620 890 5

Measurements CD 100-120 - 150 CD 100 120 150 E = Ø 80 Aspiration S =Ø 1 3/8 1 5/8 Liquid L =Ø 7/8 Empty unit weight (kg) 290 350 eight Chilled water (C) C 40 53 78 100 115 eight (kg) 350 385 545 635 730 Direct expansion (DXA) Indoor unit DXA 59 65 70 85 eight (kg) 510 510 620 620 Outdoor unit CD 100 120 150 Empty unit weight (kg) 290 290 350 This document is non-contractual. As part of its policy of continual product improvement, CIAT reserves the right to make any technical modification it feels appropriate without prior notification. Head office avenue Jean Falconnier - B.p. 14 01350 - Culoz - France tel.: +33 (0)4 79 42 42 42 Fax: +33 (0)4 79 42 42 10 info@ciat.fr - www.ciat.com Ciat service tel. : 08 11 65 98 98 (0,15 / mn) Fax : 08 26 10 13 63 (0,15 / mn) Compagnie Industrielle d Applications Thermiques - S.A. with a registered capital of 26 728 480 - R.C.S. Bourg-en-Bresse B 545 620 114 Certified Management System 6 heat pumps - AIR CONDITIONING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 14.611 A