BAND HEATERS. This technology is suitable for different industrial heating applications : Sealed mica band heaters

Similar documents
Strip/Clamp-On Heaters

Mineral Insulated Band Heater

MEGABAND * MICA INSULATED BAND HEATERS. Construction overview Clamping mechanisms Termination styles Construction styles Watt density information

Band Heaters W A T L O W. Special Mica Barrel and Nozzle

MEGABAND MICA INSULATED BAND HEATERS

High Performance Heater with More Efficient Heat

BAND HEATERS TYPICAL APPLICATIONS: SPECIAL OPTIONAL FEATURES: Plastic Injection Molding. Two piece construction. Plastic, Food, or Candy Extruders

Heaters for. Hot Runner Systems. COIL Heaters l MICRO TUBULAR COIL Heaters l. The first choice, to last...

Energy Saving Band Heaters

Strip/Clamp-On Heaters

Manifold Cleaning and System Refurbishment...N3 Nozzle Heater and Hot Runner Component Repair...N4

Band Heaters. Rectangular Band Heaters, Strip, Ring and Flat Heaters. Contact Accessories, Connection Boxes, Clamping Devices

Mineral Insulated Band Heaters

A Review on Band Heaters for Heating Performance Enhancement

Nozzle Band Heaters. Construction Characteristics. Single Port Igloo TM Covers

Screw plug immersion heaters

COIL AND CABLE HEATERS. Mightyband Cable Heaters Tempco-Pak Cable Heaters

BAND HEATERS component parts

Industrial Heaters for Plastic Applications

W A T L O W. Straight Resistance Wire. Welded End Cap

Cartridge Heaters. Metric FIREROD Cartridge. Applications and Technical Data

Coil Heaters, Mini Coil Heaters, Formable/Flexible Tubular Heaters

Phoenix Thermal Supply

HEATERS & SENSORS INC. - CATALOG

CYLINDER PLASTICS CERAMIC BAND HEATERS. Main technical characteristics: Mechanics. Electrics

PRODUCT LISTING Tubular Heater Finned Heater

Flange immersion heaters

Unheated straight section Fast response time Choice of lead protection Longer heater life Higher watt densities Made to customer specifications

Thermal Devices, Inc. Mount Airy, Maryland USA C D E F. Typical Maxiband Clamping

Helically wound resistance wire coil made

W A T L O W. Straight Resistance Wire. Welded End Cap

PIROWATT - High Power Cartridge Heaters -

ZAK M MC KHK Z ZAW ZWM heater: aluminium clamp band: stainless steel or FAL

Thermo-Platens. Cast-In Aluminum and Bronze Platen Die Heaters for Plastics Processing Equipment

HOTCO BAND HEATERS FLEXIBLE BAND HEATERS - MICA INSULATED CONSTRUCTION AND LIMITATIONS ELECTRICAL TERMINATION WELDED BAND HEATERS - MICA INSULATED

Capabilities Catalog 12298_Tutco_Catalog.indd _Tutco_Catalog.indd 1 11/18/10 8:21:11 AM 11/18/10 8:21:11 AM

B C D. Strip Heaters. Channel Strip Heaters Ceramic Insulated. To order, call or shop online at omega.com SM

B C D. Strip Heaters. Channel Strip Heaters Ceramic Insulated. To order, call or shop online at omega.com SM

Coil Heaters. Design Features: Typical Applications: Coil Heaters

Heated tools. Semiconductor equipment

High-Performance Bolt Heaters

Industrial Heaters for Packaging Applications

Coil & Cable Heaters. Table Of Contents

STRAIGHT & FORMED TUBULAR HEATERS

BRINGING WARMTH TO YOUR WORLD

Typical Applications. Braking Resistor Core Drying Dehumidification Forced Air Comfort Heating

Industrial Cast-in Circulation Heaters for ATEX/IECEx hazardous areas or in non-atex version

Cartridge Heaters. Components. Application Guidelines

Cartridge/Insertion Heaters

Pipe Thread Heaters. Construction Features. Star Electric to Order Call " 2-1/2" Pipe Thread Heaters

Heat on. Air heaters. Blowers. from 400 Watt to Watt. from 1,45 m 3 /min to 16,5 m 3 /min

Nozzle/Slip-On Heaters

Silicone Rubber Heaters FLEXIBLE HEATERS

MEGAWAT * HIGH DENSITY CARTRIDGE HEATERS

Cartridge/Insertion Heaters

Radiant Heaters. Radiant Heaters

10-14 SECTION TUBULAR HEATERS

Hotwatt, established in 1952, began with the manufacturing of one product, the open coil heating element. Since then Hotwatt has expanded our product

Cast-In Heaters Product Inventory Available for Viewing and Air-Cooled Extruder Systems

Are You Operating Your Extruders with Liquid Cooling? If You Answer Yes Then You Are SO Ready for a

innovative heating solutions

Tubular Heaters and Heating Elements

Frequently Asked Band Heater Questions Plus

Ceramic Fiber Heaters

Differences Among Screw Plug Immersion Heaters

Section N. Application Information. Thermal Manufacturing Solutions. Extrusion N-1. Injection Moulding N-2 N-3. Other N-4

MARATHON HEATER. File # E Made in USA

Frequently Asked Heater Questions Plus

Machining: Moderate to Extensive. Pattern Shop

Electric Air Heating Standard product ranges

Tubular Heaters Series

HotRod CARTRIDGE HEATERS

OWNER S MANUAL LOW-POWER SCREW-IN AND FLANGE-MOUNTED IMMERSION HEATERS (MAXIMUM 3 PINS)

Pipe Thread Heaters. Construction Features. 1" 2-1/2" Pipe Thread Heaters

PRODUCT CATALOGUE for the PLASTICS, PACKAGING and RUBBER INDUSTRY

Tubular Heaters Introduction. Tubular Heater Introduction. Design Guidelines. View Product

Nominal Diameter mm (in) mm (in) mm (in) mm (in) mm (in) mm (in)

SCREW PLUG IMMERSION HEATERS

Pictorial Index... A-4 Mi-Plus (Mineral Insulated Band) Duraband (Mica Band) Injection Molding Replacement Band Heaters...

C D E F. Tubular Industrial Process Circulation Heaters. Circulation Heaters. View Product

ELECTRIC HEATING. we get to the point... Gräff GmbH Bonner Strasse 54 D Troisdorf Tel: +49(0) Fax: +49(0) ISOMA

Machining: Moderate to Extensive. Pattern Shop

Tubular Heaters Rev 4 ( ) Finned Tubular Heaters. Finned Tubular Heaters. View Product

Cartridge Heater Solutions

RENEWAL PARTS IDENTIFICATION. Type TTUH and TTUH-CO URN Heaters. Dimensions (In.) Extends. Model Volts kw W/In 2 A B C D

Conductive Heating Technologies for Medical Diagnostic Equipment. Russell Strehlow, Manager of Research and Development, Minco

INFRARED. - Infrared Heaters with Ceramic Insulation -

HEATERS MOUNTED ON THREADED PLUG

SECTION DUCTWORK. A. Section Painting: Weld priming, weather resistant, paint or coating.

Cartridge Heaters. temperatures up to 450 C. heaters in difficult applications. 2. High impact ceramic cap retards HotRods are available in a wide

Machine needle shut-off nozzle Type SHP (high performance) spring operated

Machining: Moderate to Extensive. Pattern Shop

Tubular Industrial Process

Flexible Heaters. of Silicone Rubber & Kapton

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 350 SERIES CIRCULATION HEATERS

Radiant Process Heaters. Gemini. Medium Wave Heaters Twin Bore Quartz Tube Technology

VACUUM VALVES AND HOSES

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Cartridge Heaters. Hi-Density Cartridge Heaters. Features. To order, call or shop online at omega.com SM

Heating Cables and Tapes. Technology. Constant wattage tapes

Transcription:

BAND HEATERS Band heaters are elements with different diameters and heights, designed to heat and to maintain the temperature of cylindrical parts. Heat transfer is usely achieved by conduction or by radiation for high power heaters. They are suitable for solid heating as well as for liquids or gases heating. The applications for band heaters are various : they can be fitted to nozzles or extruder barrels, used to process plastics or today s materials such as resins which require high temperature or for heating conducts. They can also be used in plastic injection, moulding as the process of materials requires high heating power and high temperatures. Acim Jouanin band heaters combine lightness, compactness and are used in applications requiring fast temperature rises. Besides a wide range of standard sizes our technology offers multiple combinations of wiring and clamping systems. Standard band heaters are available as specific products and perfectly suit your requirements thanks to the addition of holes and cutouts, various options and/or of thermal insulation material, in order to reduce heat losses. This technology is suitable for different industrial heating applications : o High humidity... o Standard application... o Requirement of high temp. levels... o Need for robustness... o Thermally Insulated installation... o System with restricted thermal inertia... Encapsulated sealed mica nozzle heaters, Sealed mica band heaters band heaters band heaters, Heaters with mineral insulation Band heaters with radial connection plug Band heaters with energy saving Ventilated band heaters assembly BAND HEATERS FROM STOCK Sealed nozzle heaters band heaters NON STOCK BAND HEATERS Sealed nozzle heaters band heaters UL certified h. with clamping sheath Sealed mica heater High watt density mica heaters band heaters CLAMPING DEVICES CONNECTIONS OPTIONS SPECIAL BAND HEATERS Band heaters with radial connection plug Band heaters with mineral insulation Energy saving band heaters Ventilated band heater assembly EXAMPLES OF SPECIAL BAND HEATERS FITTING INSTRUCTIONS HOW TO DEFINE A BAND HEATER p 2 p 4 p 5 p 6 p 7 p 7 p 7 p 8 p 9 p 10 p 12 p 13 p 14 p 15 p 16 p 17 p 17 p 18 1

STANDARD ENCAPSULATED SEALED NOZZLE HEATERS Max. watt density over the surface of the heater: 6.5 W/cm² Max. operating temperature over the surface of the heater: 340 C, depending on working conditions. : to 100 mm : to mm Wattage : to 9 W, 2 V single phase For other dimensions, not kept in stock, see p 5 Sealed band heater in brass, with folded ends. Band heater connection, waterproof technology. Electric insulation by mica plate. Connection : nickel core, fiberglass insulated + earth wire; protected by a galvanized steel braid. Connection cap : axial, centred on the height of the band heater, up to mm height. Over mm height, it is placed at mm from the edge. (See sketch). (Except LC26G10*) Square angle flange clamping, screw BTR M4, self-locking square nuts. Our products are in accordance with EN 3-1 Wattage tolerance: +5% -10% Leakage current < 0. ma/kw Special manufactures : - Sealed stainless steel nozzle heater (see picture on next page). - Max. watt density : 5 W/cm². - Specific sealed nozzle heaters not kept in stock, see p 5. - Accessories and options, see p 12. - How to define a special band heater: see p 18. Dimensions of a standard insulated mica nozzle heater : inside 5 mm Th : 2.8 mm mm 16 mm Cap fixed at fromthe clamping 13 mm 7 mm To each diameter of band heater corresponds a clamping capacity. For instance, a band heater with a diameter of mm can be fitted on a nozzle of mm to 31 mm. In charts below, the diameter of a band heater is written in green and below it, its clamping capacity is written in black between brackets. H Power P (W) Braid L Part number H Power P (W) Braid L Part number (mm Watt. W (W) Braid L Part number ( to 26) 26 (26 to 27) 28 (28 to 29) ( to 31) 85 105 1 1 2 115 1 100 1 1 1 2 85 110 110 1 1 1 1 1 185 185 2 00 1 1 LC6A5 LC8A5 LC10A5 LC12A5 LC14A5 LC26G10* L26C11A5 L26C13A5 L28C7A5 L28C7A10 L28C7A L28C10A5 L28C12A5 L28C15A5 L28C17A5 L28C22A5 LC8A5 LC11A5 LC11A15 LC13A5 LC13A10 LC13A15 LC16A5 LC16A10 LC18A5 LC18A10 LC23A5 ( to 31) 32 (31 to 32) 34 (34 to ) 2 285 285 310 115 1 1 0 1 195 195 195 2 0 0 95 1 1 1 1 1 1 1 185 210 2 3 00 00 00 1 00 00 LC23A10 LC28A5 LC28A10 LC31A5 L32C9A5 L32C11A5 L32C14A5 L32C14A10 L32CA L32C17A5 L32C19A5 L32C19A10 L32C19A L32CA5 L32CA5 L32CA L34C9A5 L34C12A5 LC12A10 L34C12A15 L34C15A5 L34C15A10 L34C18A5 L34C18A L34C18A L34C21A5 L34C26A5 L34C32A10 ( to 39) 40 (40 to 41) 140 1 0 2 1 1 1 1 1 0 0 0 2 2 0 2 2 2 2 5 5 5 3 3 3 0 415 415 415 00 00 00 1 00 00 00 1 LC14A5 LC17A5 LCA5 LC23A5 L40C12A5 L40C12A10 L40C12A L40C16A5 L40C16A10 L40CA5 L40CA10 L40CA L40C23A5 L40C23A L40CA5 L40C27A5 L40C27A10 L40C27A15 L40C27A L40CA5 L40CA10 L40CA L40C34A5 L40C34A10 L40C34A L40CA10 L40C41A5 L40C41A10 L40C41A15 2 * Cap off center at 0 mm from the edge of the band heater. One end of the clamping tab is bevel-edged at

STANDARD ENCAPSULATED SEALED NOZZLE HEATERS 40 (40 to 41) 42 (42 to 43) 44 (44 to ) 48 (48 to 49) ( to 51) H Watt.. W (W) 415 4 4 4 1 1 2 3 3 1 1 0 0 0 2 2 0 310 310 3 3 5 4 1 1 2 0 140 185 185 2 2 2 2 310 310 310 310 3 3 3 4 4 Braid L 00 00 00 1 00 1 00 Part number Watt.. Braid Watt.. Braid H W (W) L H W (W) L Part number L40C41A L40C43A5 L40CA5 L40CA ( to 51) 4 510 5 0 00 00 LC47A LC51A5 LC56A5 LCA ( to 71) 3 3 0 440 440 LC32A5 LC32A10 LCA5 LC44A5 LC44A10 L42C15A5 L42C19A5 L42C26A5 L42C33A5 L42C33A 54 (54 to ) 0 0 2 3 3 00 L54CA5 L54CA10 L54C24A5 L54C33A5 L54C33A 440 5 5 7 1 1 LC44A15 LCA15 LCA5 LC56A5 LC73A5 0 L54CA5 785 LC78A5 L44C12A5 L44C16A5 L44CA5 L44CA10 L44CA15 L44C23A5 L44C27A10 L44CA5 L44C31A5 L44C31A10 L44C34A5 L44C34A10 L44CA5 L44C42A5 L48C13A10 L48C18A5 L48C22A10 L48CA LC14A5 LC18A5 LC18A10 LC22A5 LC22A10 LC27A5 LC27A10 LC31A5 LC31A10 LC31A15 LC31A LCA5 LC39A5 LC39A10 LC47A5 LC47A10 56 (56 to 57) 58 (58 to 59) ( to 61) 64 (64 to ) 68 (68 to 69) 3 3 1 2 2 2 2 3 3 3 3 3 3 4 4 4 4 5 5 6 7 185 240 400 4 310 00 1 1 00 1 L56CA5 L58C36A5 LC17A10 LCA5 LC22A5 LC27A5 LC27A10 LC32A LC32A5 LC32A15 LC37A5 LC37A10 LC37A15 LC42A5 LC42A LC47A5 LC47A10 LC52A5 LC57A5 LC62A5 LC78A5 L64C18A5 L64C24A5 L64C40A15 L64CA5 L68C31A5 72 (72 to 73) 74 (74 to ) ( to 81) ( to 91) 94 (94 to 95) 100 (100 to 101) 3 340 5 3 4 5 6 6 415 6 8 8 4 9 9 00 L72C33A10 L74C34A10 L74C59A5 LC36A5 LC43A LCA5 LCA10 LC57A5 LC63A5 LC63A10 LC41A10 LC64A10 LC87A5 L94C83A10 L100C46A5 L100C97A5 L100C97A10 Stainless steel sealed nozzle heater (Special manufacture) Sealed nozzle heater, in brass. 3

STANDARD MICA BAND HEATERS AVAILABLE FROM STOCK Max. watt density over the surface of the heater : 5 W/cm² Max. operating temperature over the surface of the heater: 340 C, depending on working conditions. Available in 2 versions: - wire connection: wiring with a large bending radius, nevertheless quite fragile. - metal braid connection, embossed exit: appreciated for its low profile. Nickel core, fiberglass insulated + earth wire. For the model with embossement connection, the wires are protected with a galvanized steel braid. Voltage: 2 V single phase. Electric insulation with mica plates. Square angle flange, screw CHC M4 and square nuts. Products are in accordance with EN 3-1 Wattage tolerance : +5% -10% Leakage current < 0. ma/kw Dimensions of a standard mica band heater : 16 mm 5 mm inside Th. : 2.8 mm To each diameter of heater corresponds a clamping capacity. For instance, a heater with a diameter of mm can be fitted on a nozzle with a diameter of mm or 31 mm. In charts below, the diameter of a band heater is written in green and below it, its clamping capacity, is written in black between brackets. Special manufactures : - Specific sizes of heaters, not kept in stock, see p 5. - Accessories and options, see p 12. - How to define a special band heater, see p 18. 7 mm WIRE CONNECTION Heaters available from stock : Outside sheath in aluminized steel. : to mm Connection with ceramic beads to avoid : to mm eventual pulling of the wires,12 mm, 4 mm Wattage : 85 to 515 W height. Wiring centred over the height of the heater. ( to 26) H Watt.. P (W) 1 1 Braid L 10 Part number Watt.. Braid Watt. Braid Part number Part number H P (W) L H P (W) L AC12A5 AC12A13 ( to 39) 2 0 10 10 AC23A13 ACA13 40 (40 to 41) 515 515 00 4000 A40C51A A40C51A40 ( to 31) 32 (32 to 33) 34 (34 to ) 85 1 185 2 285 315 195 1 00 00 00 AC8A5 AC13A5 AC18A5 AC23A AC28A AC31A A32C19A5 A34C18A5 40 (40 to 41) 1 0 2 0 2 2 2 5 3 3 0 415 3 1 00 1 10 00 10 00 00 A40C12A15 A40CA A40C23A15 A40CA5 A40C27A5 A40C27A13 A40C27A A40CA10 A40C34A13 A40C34A A40CA10 A40C41A A40C37A5 44 (44 to ) 48 (48 to 49) ( to 51) ( to 61) 0 4 3 3 4 3 0 4 00 00 1 1 1 A44CA5 A44C4A A48CA AC39A5 AC39A15 ACA5 AC37A5 ACA15 ACA15 BRAID CONNECTION, WITH EMBOSSEMENT Heaters available from stock: Outside sheath in brass. : to mm : to mm Wattage : 85 to 515 W Embossement connection, wire + braid, low profile, 12 mm, 5 mm height. Exit located at 16 mm from the edge. ( to 31) 32 (32 to 33) H 32 32 Watt.. P (W) 1 1 185 Braid L Part number B32C13A5 B3232C14A10 B32C18A5 32 (32 to 33) 40 (40 to 41) H 32 Watt.. P (W) 0 2 2 Braid L 4000 Part number B32CA10 B4032C26A5 B40CA40 40 (40 to 41) ( to 51) H Watt.. P (W) 3 2 0 Braid L 4000 4000 Part number B40C37A40 B40C27A5 B40CA40 BCA10 4 Dimensions of the above heaters with wire connection, are also available with braid and embossement connection. Except heaters with heights smaller than 32 mm.

SPECIAL SEALED MICA NOZZLE HEATERS Specific products, designed as a complement of standard sealed nozzle heaters p 2 : - Specific but not kept on stock, - Tailor made, defined according to your requirements. Max. watt density over the surface of the heater: 6.5 W/cm² Max. Temp over the surface of the heater: 340 C, depending on working conditions. Available specific items are listed in the chart below. : to 100 mm : to mm Wattage : to 14 W, voltage: 2 V single phase. Manufacture of specific items not listed the charts below is subject to a feasibility and compatibility study based on current, watt density and sizes of the required heater. Other voltages on request: 12 V to 400 V, with a maximum current of 7.5 A. Brass sheath, with folded ends. Electric insulation with mica. Wiring: nickel core, fiberglass silicone insulated + earth wire, protected with a galvanized steel braid. Standard leads :, 0,, 10, 1, 00 mm. For other lengths, please specify. Connection box: axial, radial or tangential, please specify. Angle (standard), or other. See p 11. Box centred over the height of the band up to mm max. Over mm, it is located at mm from the edge. Square angle clamping flange, screw CHC M4 with square nuts. Our products are in accordance with EN 3-1 Wattage : +5% -10% / Leakage current < 0. ma/kw Ex : mica band heater with tangential connection Overall dimensions according to the chosen connection type: inside 5 mm 16 mm Cap located at 1 from the clamping Th : 2.8 mm Overall dimensions according to the chosen connection type. Dimensions range hereunder is also suitable for the following : - band heater with embossment connection. (p 4 ) (Min height of 32 mm and max. power: 10 W, 4.5 A - band heater with wire connection (p 4 ) Special manufacture: - Accessories and options, see p 12. - How to define a special band heater, see p 18. In charts below, the diameter of a band heater is written in green. Its clamping capacity is equivalent of the diameter or the diameter + 1mm. ( à 26) 26 (26 à 27) 28 (28 à 29) ( à 21) 32 (32 à 33) 34 (34 à ) 36 Haut. Watt. (W) 1 185 5 2 95 1 1 0 2 240 195 240 2 210 2 2 2 240 295 0 5 0 100 36 (36 à 37) ( à 39) 40 (40 à 41) 42 (42 à 43) Haut. Watt. (W) 1 1 1 2 2 2 310 340 3 395 105 2 0 3 3 3 4 4 485 4 4 515 5 1 2 295 3 3 400 42 (42 à 43) 44 (44 à ) 46 (46 à 47) 48 (48 à 49) Haut. Watt. (W) 4 4 5 540 610 4 4 5 6 640 1 1 210 2 285 3 3 400 440 4 515 5 5 6 2 340 0 4 4 48 (48 à 49) ( à 51) 52 (52 à 53) 54 (54 à ) Haut. Watt. (W) 540 5 6 0 4 5 640 7 1 1 2 2 3 3 410 4 5 585 628 6 7 1 2 4 4 515 5 54 (54 à ) 56 (56 à 57) 58 (58 à 59) Haut. Watt. (W) 5 5 695 7 1 210 5 400 4 4 540 585 6 6 7 8 1 215 2 315 410 410 4 510 5 8 6 0 7 8 ( à 61) 62 (62 à 63) 64 (64 à ) Haut. Watt. (W) 2 6 6 728 8 1 2 285 3 3 440 495 5 0 6 0 7 5 910 185 2 2 3 510 5 6 6 7 7 8 Haut. Watt. (W) 940 66 (66 à 67) 68 (68 à 69) 1 2 0 5 415 4 5 5 6 6 7 0 8 9 195 5 400 485 540 0 6 7 7 8 885 0 2. 5

SPECIAL SEALED MICA NOZZLE HEATERS ( to 71) 72 (72 to 73) 74 (74 to ) Heig. Watt. (W) 5 6 6 7 8 915 10 210 2 3 4 515 5 6 695 7 815 8 940 10 215 2 210 400 74 (74 to ) 76 (76 to 77) 78 Heig. Watt. (W) 4 5 6 715 7 840 910 9 10 2 285 3 415 4 5 5 6 7 0 8 9 995 11 2 2 78 (78 to 79) ( to 81) 82 (82 to 83) Heig. Watt. (W) 3 4 4 5 6 6 7 8 885 9 10 11 2 0 5 7 8 910 9 10 11 2 5 3 8 84 (84 to 85) 86 Heig. Watt. (W) 515 585 6 7 795 863 9 10 1210 2 315 5 4 5 0 6 7 815 885 9 10 1100 1240 2 86 (86 to 87) 88 (88 to 89) Heig. Watt. (W) 3 395 4 540 615 6 7 8 910 9 1053 11 12 5 3 405 4 5 6 5 7 8 9 10 11 Heig. 88 ( to 91) 92 (92 to 93) Watt. (W) 10 2 340 4 5 7 0 9 10 1100 11 13 2 3 4 5 6 740 815 895 9 10 11 15 Heig. 92 94 (94 to 95) Watt. (W) 13 2 3 4 510 5 6 4 7 910 9 10 11 12 13 98 (98 to 99 mm) H : to mm W : 285 W to 14W 100 (100 to 101 mm) H : to mm W : 2 to 14 W MICA BAND HEATERS UL CERTIFIED 6 Tailor made heaters, with UL components. Certificate number : E19. Max. watt density over the surface of the heater : 8 W/cm² Max. operating temperature over the surface of the heater: 3 C, depending on working conditions. Range of products : Inside diameter : 1 to 6 mm Outside height : to 424 mm Max. wattage 00 W Max. voltage : 0 V single phase or three phase, with a maximum intensity of A per connection. Sheath and clamping sheath in aluminised steel (standard) Band heaters also available in stainless steel. Electric insulation with mica. Connection bolts mounted on rectangular base 40 x mm (single phase). Three phase : please get in touch with us. Connection : - Without cap : terminals, leads. - With cap : plug ( V < 0V), braid. Cap direction : axial, radial or tangential. Band heaters provided with earth wire. Clamping: barrel nuts or spring loaded screws (compensated clamping) for diameters over 0 mm. See definition p 9. Thickness of the band heater (without connection) : 5 to 7.5 mm, according voltage. (The thickness of standard bandheaters is between 2.8 and 4 mm according the technology. ) Wattage tolerance : +5% -10% Dimensions of UL band heater, with terminals connection 40 mm Band heaters certified UL for USA and CSA for Canada, according to certifcate : E19 inside mm Th : 5 to 7.5 mm Gap : Outside height 5 to 10 mm depending Position of the connection according on diameter specifications of the band heater Optional accessories : support bridge, welded bracket, thermocouple. (Pictures p 12). How to define a special band heaters see p18. Manufacturing depending on feasibility study and compatibility between watt density, voltage and dimension.

MICA BAND HEATER WITH CLAMPING SHEATH Tailor-made band heaters. Max. watt density over the surface of the heater: 4.5 W/cm² Max. working temperature:340 C, depending on working conditions. : to 0 mm. Heating height : to 4 mm, depending on connection type. Clamping sheath in aluminised steel allows a proper support of heaters with important cutouts or large dimension. Electric insulation with mica. Connection: - Without cap : wire, stud or pins terminals - With cap : stud, pin terminals or braid. Cap directing : axial, radial or tangential. See the connection definition p 10. Voltage: 2 V single phase (standard). Other voltages on request, from 12 to V. Clamping: barrel nuts or spring loaded screws (compensated clamping) for diameters over 0 mm. See definition p 9. Products are in accordance with EN 3-1 Wattage tolerance : +5% -10% Leakage current < 0. ma/kw Overall dimensions of a mica band heater with clamping sheath inside 5 to 10 mm, depending on the diameter. Th : 4 mm Overall dimensions according to the connection type. Ex : wire connection. band heater with stainless steel clamping sheath and pictogram Special manufactures: - Accessories and options, see p 12. - How to define a special band heater, see p 18. The band heaters shown below are tailor-made and are not kept in stock. They can be fitted with accessories and options, see p 12. To define your requirements, please, see form p 18. SEALED MICA HEATER Heater designed to complete our range of nozzle heaters, with heights over mm. Max. operating temperature over the surface of the heater: 340 C, according to the working conditions. MICA BAND HEATERS Max. watt density over the surface of the heater : 6.5 W/cm² : to 0 mm. : to 4 mm. Thickness : 2.8 mm Brass or stainless steel sheath metal, brazed or welded. Electric insulation with mica plates. Connection: galvanized steel braid in CMBPE type cap, axial directing at angle. See p 10. Clamping types : square angle flange or barrel nuts. See p9 Standard clamping gap of the heater: 5 mm. HIGH WATT DENSITY MICA BAND HEATER Model designed for heating applications requiring high watt density. Max. working temperature over the surface of the heater : 340 C, depending on the working conditions. Max. watt density over the surface of the heater: 8 W/cm² : to 1 mm. : to 111 mm. Thickness: 3 mm Sheath metal : aluminized steel. Electric insulation with mica. Connection : Wire connection coming from the thickness. p 10. Clamping with straps fitted with barrel nuts and M4 screws, lenght according to the diameter of the heater. Standard clamping gap of the heater: 5 mm LARGE DIMENSIONS MICA BAND HEATERS Max. manufacturing dimensions for mica band heaters: 6 mm diameter, 0 mm height. Possibility of manufacturing heaters with very large diameters, to be used for drum heating. Several models of belts, with or without thermal insulation or waterproof are available from stock. See the "Drum heater" section. 7

CERAMIC BAND HEATERS Tailor-made heaters. Max. watt density over the surface of the heater: 9 W/cm² Max. working temperature over the surface of the surface of the heater: 0 C, depending on working conditions. : à 6 mm. (min : mm, for tangential connection box with terminals.) Heating height : to 4 mm (multiple of 15 mm). Mini height is defined according to the chosen connection type. Total height : heating height + 4 mm for the thickness of the clamping sheath folded over the edges. Clamping sheath in aluminized steel, stainless steel or inconel, depending on the working temperature and surroundings. band heater in stainless steel, with barrel nuts clamping Overall dimensions of a ceramic band heater. Electric insulation with steatite elements. Thermal insulation, located between the ceramic mat and the clamping sheath. Connection: - Without cap : wires, stud, terminals. - With cap : stud terminals, pins or braid. Directing of the cap : axial, radial or tangential direction. See the definition of the connection, p 10. Voltage: from 2 V single phase (standard) to 400 V three-phase, star or delta, according to the connection. Max voltage : V. Other voltage availabe. Please consult us. Clamping: barrel nuts or spring loaded screws (compensated clamping) for diameters over to 0 mm. See the definition of clamping variations, p 9. Products are in accordance with EN 3-1 Wattage tolerance: +5% -10% inside Gap : 10 mm min. Th. : 12 mm Overall dimensions according the connection type. Sketch hereabove : leads termination. Products are in accordance with EN 3-1 Leakage current < 0. ma/kw Total heignt Special manufactures : - Accessories and options, see p 12. - How to define a special band heater, see p 18. band heater, 2 pins radial plug connection with compensated clamping. band heater, with B.A.J. option stud terminals in terminal box and barrel nuts clamping. band heater with thermocouple bridge, 2 pins radial plug connection and barrel nuts clamping. band heater, with cutouts, (holes and slots). 3 pins UTFCEE plug connection and compensated clamping. 8

CLAMPING VARIATIONS FOR BAND HEATERS Barrel nuts 13 mm mm mm Barrel nuts and spring loaded screws (compensated clamping) 1 mm 21 mm 21 mm Barrel nuts clamping, threaded barrel and BTR M6 screws. According to the dimensions of the heater, and/or depending on space restriction, the clamping system can be fitted: either on straps, independently of the heater or on a clamping sheath. Barrel nuts clamping, threaded barrel and BTR M6 screws and heavy duty springs, allowing a powerful positive clamping. According to the dimensions of the heater, and/or depending on space restriction, the clamping system can be fitted either on a clamping sheath (used in most applications), on straps independently of the heater. Square angle flange 13 mm 40 mm Sliding keyway 4 mm mm Clamping with BTR M6 screw and square locking nuts. band heaters: Square formed by clamping sheath with edges folded at angle. Clamping sheath band heaters: heavy gauge metal square welded to the clamping sheath. As standard, the clamping height is equal to the height of the heater. Both ends of the clamping sheath are shapped as a channel. Clamping is achieved with a trapezoidal keyway sliding over these channels. The keyway is forced fitted. Clamping sheath has the same height as the heater. The height of the keyway is the same as the heater minus 10 to 15 mm. The number of clamping devices is defined according to the dimensions and to the electrical characteristics of the band heater. Clamping assembly : - As standard : clamping is in the gap of the active element (1) - Special manufacture: clamping is out of line with the gap (2). These heaters are fitted with a clamping sheath. Quick release fasteners mm mm (1) (2) Gap of the heater Gap of the heater Clamping system fitted on anti-burning clamping sheath or on energy saving heaters, BAJ type. (See p 15 ). Band heaters fitted with a clamping sheath. Barrel nuts By default: - clamping sheath, - Sealed mica heater with clamping sheath. -. Optional assemblies: - Øi < 0 mm. Spring loaded screws By default: - Øi 0 mm - Øi 0 mm. Optional assemblies : - clamping sheath, - Sealed mica heater with clamping sheath, - Encapsulated nozzle heater, and clamping sheath. Square angle flange By default: - Øi < 0 mm. - Encapsulated sealed nozzle heater Optional assemblies : - clamping sheath, -. Possible assembly but not recommended : - Øi > 100 mm In case of space restrictions, please consult us. See p18, How to define special band heaters. Key way Optional assembly: - Øi < 100 mm. Possible assemblies but not recommended: - clamping sheath (option ) - Øi 100 mm. - Øi < 100 mm. Quick release fastener Optional assembly: -, - Energy saving band heaters, - Band heaters fitted with an anti-burning sheath. 9

CONNECTIONS FOR BAND HEATERS Description of the different connections, with and without cap: o Wires : flexible wires, nickel core, fiberglass insulated, designed for a maximum operating temperature of 340 C. o Connection with embossement and leads in the thickness : each conductor is protected by a galvanized steel braid. o Terminals : M4, M5 or M6 threaded terminals, depending on the watt density, mounted with 2 washers and 1 nut per terminal. o Plugs : 2 pins, 6 mm, axe 19 mm, in nickeled stainless steel. Connection boxes, other models of pins in option. See p12. o Braid (specific for termination with cap) : 2 conductors wire termination, protected by a galvanized steel braid. All of our band heaters are provided with an earth wiring, by default. Delivery without ground wire, only on request. CONNECTIONS WITHOUT CAP Legend Orientation of the connections Gap Both terminations on the same side, parallel to the gap Both terminations on the same side, perpendicular to the gap One termination on each side ot the gap H Inside diameter i Standard band heaters are in aluminised sheath or stainless steel as option ( no stainless for steel band heaters with wires in the thickness and connection with embossement). The dimensional ranges are the same for those two types mentioned above, except special specifications. Connection without cap, single phased, are centered on the band heater s height. (except for connections leads in the thickness and leads under embossement). Dim. between the two axes: 19 mm. Connections, on the same side, parallel to the gap Pins Intensity < 9 A Øi : to 1 mm H : to 215 mm with clamping sheat Øi : to 0 mm H : to 215 mm Connections located on each side of gap Terminals Intensity < 13.5 A Øi : to 1 mm H : to 111 mm with clamping sheath Øi : to 0 mm H : to 111 mm : on request Terminals Intensity < 13.5 A Wires Intensity < A Øi : to 1 mm H : to 215 mm with clamping sheath Øi : to 0 mm H : to 215 mm : on request Øi : to 1 mm (alu) Øi : to 1 mm (st. steel) H : to 215 mm with clamping sheath Øi : to 0 mm H : to 215 mm : on request Connections, on the same side, perpendicular to the gap Terminals with clamping sheath Intensity < 13.5 A Øi : to 0 mm H : to 215 mm : on request Wires Intensity < A Wires under bossage Rated current < 4.5 A Wires in the thickness Intensity < 4.5 A Øi : to 1 mm (alu) Øi : 40 to 1 mm (st.steel) H : to 111 mm Øi : to 0 mm H : to 215 mm Øi : to 1 mm H : 32 to 111 mm (This heater is only available in brass) Øi : to 1 mm H : to 111 mm 10 Wires Intensity < A Øi : to 0 mm H : to 215 mm Ømin: to 0 mm H: to 4 mm Possibility to add plugs, in option. See chapter "Options" p 12 and "Accessories" documentation. Refer to p18 "How to define special band heaters to help you to define your quotation. Choose the connection type and fill in the enclosed form.

CONNECTIONS FOR BAND HEATERS CONNECTIONS WITH CAP Legend Orientation of the caps Std positioning of the cap Axial Radial Tangential band h. < 100 mm α : 1 band h. 101 mm α : Other angles on request H Inside diameter i α Connection description : Other models, in option: p.12. and ceramic b. h. : standard aluminised sheath, option stainless steel. Caps : standard aluminised plate, option stainless steel. Sealed nozzle heaters & caps : all pieces made of brass or stainless steel Positioning of caps on the height : please consult us. The sketches of the connection shown below, correspond to Øi and H ranges mentioned in the table. Other ranges, see note(1). Models of caps, below, for single phase connection. Possibility of three phase (stud terminals and braid), commutable or not. Please, consult us. Axial orientation Pins- Intensity < 16 A (single phase) 72 Øi : to 0 mm / H : 44 to 424 mm Other range (1) : Øi : to 2 mm / H : to 43 mm 42 Ømin: mm / H : to 4 mm Terminals - Intensity < 13.5 A (single phase) 36.5 Øi 53.5 : 95 to 0 mm / H : to 424 mm Other range(1) : Øi : 95 to 2 mm / H : 40 to 69 mm 57 Braid + CMBPE type cap, angle - Intensity < 7.5 A (single phase) Sealed mica (brass) Øi : to 2 mm / H : 91 to 215 mm 13 Sealed mica (stainless steel) Øi : to 2 mm / H : 61 to 215 mm Øi : to 2 mm / H : 41 to 1 mm Other orientations : radial or tangential, with different slopes. (see p12) Braid + small bulk cap - Intensity < A (single phase) 40 13 Øi: to 2 mm / H: to 49 mm & Øi: to 0 mm / H: to 111 mm I max : H 111 mm: 13.5 A, beyond A. Other range (1): Also available with radial or Øi: to 0 mm / H: 112 to 424 mm (I max A) tangential ends. Braid - Intensity < A (single phase) 42 Øi : to 0 mm / H: 44 to 69 mm & Øi : to 0 mm / H: to 424 mm 42 Ømin: mm / H: to 4 mm Radial orientation Pins - Intensity < 16 A (single phase) 22 67 Øi: to 2 mm / H: 22 to 43 mm 40 et Øi: à 0 mm / H 44 to 424 mm I max : H 29 mm : 4.5 A, beyond16 A. Other range (1): 44 Øi : to 49 mm / H : 22 to 285 mm Also perpendicular avaliable on the edge of the band heater Ømin: mm - H : to 4 mm Terminals - Intensity < 13.5 A (single phase) 36,5 Øi: to 2 mm / H: to 43 mm 53,5 and Øi : to 0 mm / H: 44 to 424 mm 57 Ømin: mm / H : to 4 mm Braid - Intensity < A (single phase) Øi 22 : to 2 mm / H: 22 to 43 mm and Øi: to 0 mm / H: 44 to 424 mm 40 I max : H 29 mm : 4.5 A, beyond A. Other range (1): Øi : à 49 mm / H : 22 to 285 mm 44 Ømini mm / H: to 4 mm Tangential orientation Pins Intensity < 16 A (single phase) or braid - Intensity < A (single phase) 40 32 Øi : to 0 mm / H : 51 to 424 mm Other range (1): pins Øi : 110 to 2 mm / H : 32 to mm 78 Other range (1): braid Øi : to 2 mm / H : to mm (I max A) et Øi : to 0 mm / H : 112 to 424 mm Braid Øi : to 2 mm / H : to 111 mm (I max 13.5 A) Ømin: mm / H: to 4 mm Terminals - Intensity < 13.5 A (single phase) 40 Øi : to 0 mm / H : 51 to 424 mm Other range(1): Øi 67 : 95 to 2 mm / H : 40 to mm and Øi : 110 to 2 mm / H : to 39 mm Terminals - Intensity < A (single phase) X Ømin: mm / H: to 4 mm X: lthe cap height equals the band height In case of particular bulks, please consult us. Note (1) : for these ranges,please consult us for cap dimensions. 94 11

OPTIONS FOR BAND HEATERS The options mentioned below come in addition to options already described before ACCESSORIES Heat sensor bridge w. clamping sheath Support inserted on the heater, then welded. Thread according to the diameter of the support : 1/8 1/4 3/8 8 8 10 10 12 12 14 14 16 Pas gas gas gas 100 1 100 1 100 1 100 1 100 Welded brackets Welded bracket which can be used as cable guides or clips for all kind of small equipement. TEMPERATURE SENSORS Thermocouple Type J - 0 to 0 C Type K - 0 to C 2 possibilities: - Insulated thermocouple: under bossage connection, axial. - Insulated or not insulated thermocouple blended, brazed into a small cap type CMBPE (max. rated current 4.5 A) MARKING Special marking By default: Wattage Voltage Code ACIM Modification of customized marking. Please, consult us. SPECIAL MOUNTING Hinge on a clamping sheath w. clamping sheath w. clamping sheath clamping plate w. clamping sheath WIRING Options for CMBPE* type caps Intensity : 7.5 A Slope 0 Other angle Orientation Axial Radial Tangential Possibility to combine options of tube slope and options of orientation cap. CMBPE* type square cap Insulated brazed cap, just like the pyramidal CMBPE cap. All positions available (axial, radial, tangential). Please, mention the angle you need. CMBPE* cap installed at the edge of the band heater CMBPE type cap positionned at 11 mm from the edge and at 1 from the clamping. CMBPE cap moved forward other than 1 Ex : Cap installed at from the gap w. clamping sheath clamping plate clamping plate 12 Clamping sheath fitted with a hinge to make mounting easier. It is highly recommended to put notches on the external sheath of the heating element. Part of bandheater w. clamping sheath Band heaters can be manufactured in several parts, for different reasons like bulk, easiness of installation or manufacturing problems. For this kind of option, please, mention the angular value you need, from the gap of the band. Extended tube on CMBE cap This option is available for tubes longer than mm, for all orientations : axial, radial and tangential. Please, mention the angle. *CMBPE : Insulated mica nozzle band heater clamping plate

OPTIONS FOR BAND HEATERS Connection Special plug s assembly Ref: CEE22 Plug CEE : plug 2 poles + earth, 2V, 10A. Plug STAS : plug 3 poles + earth, 400V, 16A. For the other kinds of plugs, please, consult us. UTFCE plug Ref: STAS.3.N (male) STAK.3.N (female) w. clamping sheath w. clamping sheath Pins cap brazed on tube Interlink connector Ex : band equipped with a sensor support w. clamping sheath Option: box with pins, brazed on the tube of a CMBPE box type. Radial position only. Pins with 2 poles, 6 mm, TCT 19 mm, in nickeled steel. w. clamping sheath 2 poles 5x2 mm, space between poles 12.5 mm + earth 6x2 mm. 240 V, 16 A. Beaded wires They protect the wires from high temperatures. Length to be specified, by multiple of 100 mm. Ex. of assembly on a band heate r equipped with a hinge Thanks to this option, you can connect 2 parts with only one connection. Without earth ground wire Our bands are equipped with earth ground wire. If you don t need it, please mention it on your order. SHEATHED HEATER WITH RADIAL CONNECTOR Max. watt density on the tubular element : 4.8 W/cm² Max. operating temperature over the surface of the heater : 4 C min : 139 mm min : 18 mm Wattage : to 1015 W - Voltage: 2 V or 400 V single phase. Other dimensions upon request. Clamping sheath in aluminised steel Stainless steel tubular element. Dimensional of a standard radial connector band heater: 40 27 Radial box connection, with nickeled steel pins 6 mm, space between axes 19 mm, and cover pins. Earth connection, thanks to the pin connector. 44 inside 22 Clamping : welded clamping barrels and BTR M6 screws, positioned on the clamping sheath 10 Th.: 9.5mm Our products follow the EN 3-1 norm Wattage tolerance : +5% -10% Leaking current < 0. ma/kw Special manufacturings: - How to define a special band heater, see p 18. 139 mm H 18 Voltage (V) 2 2 Wattage (W) 1015 Stock B13918CU22 B139C101U22 As the tubular element is bent on a specific diameter, heaters must perfectly suit to the support. 139 18 400 400 1015 B13918CU B139C101U 13

MINERAL INSULATED BAND HEATERS AVAILABLE FROM STOCK Very high watt density band heaters (W/cm²) CHARACTERISTICS Standard watt density over the surface of the heater: 10 W/cm² Max. operating temp. over the surface of the heater: 0 C, under specific conditions. : to mm : to mm Wattage : from 0 to 8 W, 2 V. Covering sheath in stainless steel. High watt density, electric mineral insulation. Standard connection : nickel core, silicone fiberglass insulated high temperature. Leads protected by a galvanized metallic braid, length 3 mm. Axial cap, at the edge of the band heater. Standard clamping : clamping sheath + barrel nuts. Special clamping : sliding keyway (see below). Products are in accordance with the EN 3-1 norm: Wattage tolerance : +5% -10% Leakage current < 0. ma/kw Dimensional of a standard mineral insulated band heater: 13 mm inside Gap : 4 mm 8.8 mm Th. 5 mm max. 27.5 mm Dimensional of a heater without its clamping system. Clamping type to be defined according to your available space. Clamping sheath + barrel nuts : Clamping with sliding keyway : Clamping by BTR M4 screw, mounted on a sheath having the System designed for assemblies with little space. Mainly same height as the heater. This sheath is set directly on the used for little diameters of band heaters. Folded clamping heater to avoid any expansion. sheath on which slides the sliding keyway. mm 15 mm +14 mm 10 mm mm H Wattage (W) Stock H Wattage (W) Stock H Wattage (W) Stock 32 0 2 2 0 3 0 3 340 400 MCA3 MCA3 MCA3 MCA3 MCA3 MCA3 MCA3 M32C32A3 MC34A3 MC40A3 40 42 4 3 400 4 5 6 0 4 440 MC48A3 M40C33A3 M40C40A3 M40C46A3 M40CA3 M40C58A3 M40CA3 M40CA3 M42C42A3 MC44A3 5 5 6 0 0 7 8 MCA3 MCA3 MC58A3 MC62A3 MCA3 MCA3 MCA3 MC88A3 With high watt density and high working temperatures, mineral insulated band heaters must be perfectly adapted to their support. Therefore, their clamping capacity has to be the same as the diameter of their support. 14

ENERGY SAVING BAND HEATERS The energy saving BAJ band heaters are specially set up on injection moulding machines and extrusion heads. By combining a band heater to a BAJ insulation system, we can guarantee a very low heating loss, both conductive and radiative. This system allows a lower energy consumption than compared to an installation equipped with standard, non insulated band heaters. This system exists in 2 types : - mini B.A.J. : insulation provided by a thin layer of insulator, energy saving of 15% on average. - B.A.J. : insulation provided by a thick layer of insulator, energy saving of 40% on average. Cut showing us different thickness of materials of a heater fitted with a B.A.J. system and an anti-burning plate. heater supplied with a B.A.J. system and an antiburning plate. The energy saving band heater technology also called BAJ (Brevet Acim Jouanin), can be adapted to all kind of band heaters, mica and ceramic. The particular design allows a very good preservation of the insulator even with high temperature. The advantage of the BAJ is the thermal isolation of each bandheater, which enables to respect the different heating zones on injection and extrusion lines. DIMENSIONS Thickness : b. heater + BAJ CHARACTERISTICS External sheath, in polished steel or steel treated in the surface, protecting the insulator from all sort of compression. It acts like a reflector, spreading the radiation towards the surface to be heated. The outside frame is made of two halfs cylinder connected by a hinge for easy mounting on the sheath. Insulating structure with a low thermal conductivity, placed between the frame and the band heater. The thickness of the the insulator has been specially improved in order to minimize eventual loss. or ceramic band heaters, depending on the application. Their thermal capacity respects all insulation factors in order to avoid overheating problems and premature failure of the band heater. IP 40 band heater. The band heater and the frame are clamped with barrel nuts, which allows a strong clamping and is specially designed for a mounting where space is limited. Sizes without connection cap. Thickness b. heater + BAJ + anti-burning Kind of band heater Insulated ceramic heater (B.A.J.) Insulated ceramic heater (B.A.J.) with anti-burning sheath Insulated mica heater (mini B.A.J.) Insulated mica heater (B.A.J.) Insulated mica heater (mini B.A.J.) with anti-burning sheath Thickness 28 mm mm 10 mm mm mm band height band height + BAJ band height, BAJ + anti-burning Total height H + 6 mm H + 11 mm H H+ 6 mm H + 11 mm Connection under cap : axial, radial or tangential, set up on the outside frame. Different types of connection, see p 11. Products are in accordance with the EN 3-1norm Wattage tolerance : +5% -10% Leakage current < 0. ma/kw. Manufacturing depending on feasibility study and compatibility between watt density, sizes and accessories. OPTIONS - Mini BAJ assembly on a mica band heater : Option 6 - BAJ assembly on a mica or ceramic band heater. In order to protect users from eventual burning, an antiburning sheath (also called open work sheath) can be installed on a band heater supplied with the BAJ system. The energy saving band heaters can be fitted with sensors supports. See option 2, p12. 15

BAND HEATERS WITH BLOWER ASSEMBLY Ventilated band heaters are some heating units fitted with forced air blowers. This system enables a faster cooling of the scabbard. Mostly used for extruders and press moulding machines, this technology allows efficient working of the resin and of the sensitive plastic materials, which need high and stable working temperatures. A ventilated band heaters assembly enables to prevent barrels from the self-overheating effect. The association between band heater and ventilation is a good answer to these requests : - quick heating process thanks to band heaters, - quick cooling thanks to the ventilation system by forced air heating, minimizing the thermal inertia of the scabbard. band heater with blower assembly CHARACTERISTICS DIMENSIONS The frame made in polished or treated stainless steel consists of 2 halfs cylinders connected by a hinge. This one will channel the air on the scabbard in order to optimize the cooling effect. A security system maintains the frame on the scabbard to enable intervention without the risk that it separates from the scabbard. Band heaters are set up on a frame gathering the connections of band heaters. (Number of band heaters depending on space). An intensive cooling effect generated by the forced air blowers and combined to a good thermal conductivity thanks to the dielectric insulator of the band h. will allow rapid elimination of calories. or mica band heaters, according to the application. IP 40 band heater inside Th. : (See chart below) The band heaters clamping is made barrel nuts. The frame is closed by adjustable fasteners. Connection : terminals under box, single or three phase voltage. Tangential or radial position, centered on the height of the ventilated assembly and fitted on the frame opening. Products are made in accordance with the EN 3-1 norm Wattage tolerance : +5% -10% Leakage current < 0. ma/kw. The dimensions of the fans cannot be mentioned because their bulk is particular to each application. H : height of the band heater Kind of band heater Ventilated ceramic band heater Ventilated ceramic band heater and anti-burning sheath Thickness mm mm OPTIONS To define your product, refer to p 18. In order to protect users from eventual burning, an antiburning sheath (also called open work sheath) can be installed in a band heater wih blower assembly. Ventilated mica band heater Ventlated mica band heater and anti-burning sheath Dimensions without fan. mm mm Band heaters with blower assembly, can be fitted with temperature regulating sensors. In this case a special boring should be foreseen. See option 2, p12. The manufacturing of "heaters with blower assembly", units are subjected to our approval, depending on power rating, current, sizes, terminations and accessories. Please, consult us.. 16

EXAMPLES OF SPECIAL BAND HEATERS To define this kind of bandheater, we request you to send us your precise specifications. Pictures for information only. Part of mica band heater with clamping sheath, equipped with optional UTFCEE plug (option). band heater fitted with a B.A.J. system and various cut and holes. band heater divided in several heating parts, each one having its own connection band heater, with brass sheet and specific clamping band heater with cutouts and clamping by specific square angle flange band heater with cutouts in various shapes and clamping by adjustable fasteners. Small diameter ceramic band heater equipped with the optional temperature sensor support. ASSEMBLY RECOMMENDATIONS FOR BAND HEATERS To favour heating transfer between the band heater and its sheath, some precautions have to be taken. For futher information, please see the assembly instructions : We advise you to use a band heater whose wattage covers the heating needs. A band heater with too high power could increase not only the risk of overheating but also the switching frequency of the temperature controller. Do not operate above rated voltage, watt density or temperatures. Excess voltage, wattage or temperature could alter the life time of the band heater. Our band heaters are designed to operate according the principle of heating conduction : they must never operate in air without any support. Please avoid to open band heaters during their assembly on the sheath : irreversible internal damage could occur. If possible, they must be slipped over the end of the scabbard. Only the mica band heaters equipped with a hinge or the ceramic band heaters can be opened. Band heaters and wirings must be protected from eventual material contamination in order to preserve their heating capacity. Before the assembly, the barrels have to be cleaned. Band heater barrel Advised disposition : - the inside diameter of the band heater must perfectly fit on the diameter of the barrel in order to facilitate a good heating exchange. - the connection must be placed upside down, in order to avoid any overheating. Band heaters undergo a loosening effect after the first heating cycle. It is necessary to tight them again in order to improve heating transfer. 17

HOW TO DEFINE A BAND HEATER Company... Tel :... / Fax :... Contact name :... Department :... Date :... Brand of machine where the heater is installed on :... Kind of band heaters : band heater (p 4 and 7) Sealed nozzle mica heater (p 2 et 5) band heater (p 8) b. h. with radial connection (p 13) Connection : Same side, gap Same side, // gap Also available on our web-site : www.acim-jouanin.fr Dimensional of the heater : :... :... Wattage (W) :... Voltage (V):... Single / Three phase Connections on each side Material of the heater : Aluminised steel Stainless steel Brass Number of pieces:... Please, precise type of bandheater and type of connection. For cable connection, please precise type of wires and length. - Axial Radial Tangential Connection under cap - - - - - - Wire connection : Standard (fiberglass) High temperature wires Silicone cable Metallic braid Other :... Length multiple by mm :... Protection : Bead Length :... radial connection only - - Sealed mica Connection braid : Mutiple by mm :... CMBPE cap : Mention the angle of the cap : 0 Other :... Clamping: 3 - Square angle flange 1 - Barrel nuts 4 - Sliding keyway 2 - Compensated 5 - Quick release clamping fasteners 2 - - Options and special manufactures: For the following information, please, specify the position and the dimensionsal on the sketch below. Hole : :... Quantity :... Cutout: Length x width :... Quantity :... Support for sensor: + thread pitch:... Other options (all usefull information) :......... 1 2 3 4 5 The angular values for position of connection, holes and sensor support have to be written clockwise, with the clamping as the point of reference. This form is only used to make an quotation. A drawing may be asked for manufacturing. Gap Other information......... Inside diameter... 2 Ø i............... 1 The manufacturing of bandheaters depends on copmpatibility between wattage, intensity, dimensions, connection, accessories and options. ACIM JOUANIN - 6, Rue Vulcain - Z.I. n 1 Nétreville - BP 17-217 EVREUX Cedex - FRANCE Tél : 33 (0)2.32.62.34. Fax : 33 (0)2.32.62.34.29 E-mail : export@acim-jouanin.fr Web : www.acim-jouanin.fr 18

HOW TO DEFINE A BAND HEATER To process your order or quotation for a mica or a ceramic band heater please specify the following technical information. When placing your order do not forget to enclose this shuttle form which will allow us to determine the parameters of your product. Company:... Tel :... / Fax :... Contact name :... Department :... Date... Application : Rise in temperature Heating + Maintain in temperature Maintain in temperature only Product to be heated:... ο Mass or volume (static product) (kg or m 3 ) :... Flow (m 3 /h) :... ο Initial temperature ( C) :... Final temperature ( C) :... Ambient temperature( C) :... ο Time for rising in temperature ( hours) :... ο Characteristics : Density (kg/m 3 ):... Specific heat (J/ kg.k) :... Thermal conductivity (W/m². C)... ο ο Special information about the product :...... Does the state of the product change during the heating (e.g. : a solid becomes liquid) :... Melting point ( C) :... Latent heat of fusion (J/kg)... Brand of the engine on which the band heater will be mounted :... ο Area to be heated: :... :... Number of band heaters needed :... (subject to manufacturing) ο ο ο Electrical energizing of the band heater: Voltage (V):... Single phase / Three-phase Connection of the band heater: Wires or braid : lenght :... Pins Terminal Description of the band heater : Materials of the support on which the b.a will be mounted... Dimensions :... Weight or volume of the support (kg or m 3 ) :... Description : Density (kg/m 3 ):... Specific heat (J/ kg.k) :... (W/m². C)... ο ο ο Bulk around the support :... Band heater clamp (if defined) :... If the band heater needs holes or any other drilling, please, mention it on the drawing on left. Please send a drawing of the element you need to heat. This will help us to calculate the heat losses and to adapt the heater, taking into account the possible dimension requirements (e.g., identations) Environment: ο Use: food, industry, plastic... corrosive surrounding... Special leak tightness, reinforced insulation:......... Band heater material (if known): Alluminated Stainless steel brass ο Operating place : inside or outside, heated place or not, wind,...... Regulation : ο Temperature controllers : J thermocouple K thermocouple PT100 sensor ο Model (bayonet to screw...) :... ο Sensor fittings:... Lead... ο Regulation type: On/Off PID Other :... Do not hesitate to consult our documentation Temperature sensors Band heaters are subject to compatibility of the watt density, voltage, dimension, termination, accessories and options. ACIM JOUANIN - 6, Rue Vulcain - Z.I. n 1 Nétreville - BP 17-217 EVREUX Cedex Tél : 33 (0)2.32.62.34. Fax : 33 (0)2.32.62.34.29 E-mail : export@acim-jouanin.fr Web : www.acim-jouanin.fr 19

OTHER DOCUMENTATIONS AVAILABLE ON REQUEST FR07/0136QU Temperature control Band heaters Fan heaters Immersion heaters Flexible heaters Tubular elements Formable coil heaters Carridge heaters Infrared emitters Flat (plate) heaters Ovens Barrel heating Cast in heaters Cables, sheath and accessories But also other families : Tracing, heaters on cylinder... ACIM JOUANIN Z.I. N 1 Nétreville 6, Rue Vulcain - B.P. 17 217 EVREUX Cedex - FRANCE Tel : 33/02 32 62 34 Fax : 33/02 32 62 34 29 E-mail : export@acim-jouanin.fr Web site : www.acim-jouanin.fr