ON A POSSIBLE COMMISSION REGULATION AMENDING COMMISSION REGULATION (EC)

Similar documents
COMMISSION REGULATION (EU)

COMMISSION DELEGATED REGULATION (EU) /... of XXX

COMMISSION REGULATION (EU) / of

FAQs Radio Equipment Directive (RE-D)

Implementation of the Construction Products Regulation (CPR) in harmonized standards - Template for Annex ZA -

(Non-legislative acts) REGULATIONS

Commission Working Document on possible Ecodesign Requirements for domestic ovens, hobs and range hoods

The products covered by the Regulation can be classified as follows:

A Notification under Article 12 of Regulation (EU) No 1025/2012 1

COMMISSION REGULATION (EU) No /.. of

Guidelines accompanying:

B COMMISSION REGULATION (EU)

COMMISSION REGULATION (EU)

OJ L 239, , p. 1. OJ L 239, , p. 83, OJ L 239, , p. 136.

COMMISSION REGULATION (EU)

COMMISSION DELEGATED REGULATION (EU) No /.. of XXX

7331/13 IH/sb 1 DG E

1. Terms defined in the Construction Products Regulation (CPR)

Official Journal of the European Union

COMMISSION DELEGATED REGULATION (EU) No /.. of

REDCA update on the RED. Days to go. 17 May 2017

The European Radio Equipment Directive 2014/53/EU

Annex 7: Harmonised Standards for Products covered by Ecodesign and Energy Labelling Regulations. Page 1 of 26

FREQUENTLY ASKED QUESTIONS. COMMISSION REGULATION (EU) No 327/2011. of 30 March 2011

COMMISSION DELEGATED REGULATION (EU) /... of XXX. on the classification of the frost resistance performance for clay tiles under EN 1304

COMMISSION DELEGATED REGULATION (EU) No /.. of XXX

(Non-legislative acts) REGULATIONS

CONSUMER RELEVANT ECO-DESIGN AND LABELLING REQUIREMENTS FOR REFRIGERATORS & FREEZERS

(Text with EEA relevance)

COMMISSION DELEGATED REGULATION (EU) /... of

The new Gas Appliances Regulation (EU) 2016/426

Guidelines Cooperation between authorities under Articles 17 and 23 of Regulation (EU) No 909/2014

COMMISSION DELEGATED REGULATION (EU) /... of

PRIUX HOME D. High-efficiency double circulating pumps Heating Air conditioning 50 Hz OPERATING RANGE APPLICATIONS BENEFITS

EUROPUMP ATEX Guideline Part II

COMMISSION REGULATION (EU) No /.. of XXX

A Step by Step Guide to Energy Labelling of Gaseous Fuel Local Space Heaters (Part 1)

COMMISSION REGULATION (EU) No /.. of XXX

COMMISSION DELEGATED REGULATION (EU)

COMMISSION DELEGATED DECISION (EU) / of XXX

Official Journal of the European Union L 239/1. (Non-legislative acts) REGULATIONS

Council of the European Union Brussels, 21 March 2017 (OR. en) Mr Jeppe TRANHOLM-MIKKELSEN, Secretary-General of the Council of the European Union

COMMISSION DELEGATED REGULATION (EU) /... of

Council of the European Union Brussels, 25 October 2017 (OR. en) Mr Jeppe TRANHOLM-MIKKELSEN, Secretary-General of the Council of the European Union

HIGH EFFICIENCY CIRCULATORS

DGG 1B EUROPEAN UNION. Brussels, 2 December 2016 (OR. en) 2016/0355 (COD) PE-CONS 51/16 EF 338 ECOFIN 1031 CODEC 1639

COMMISSION REGULATION (EU) / of XXX

European Parliament and of the Council with regard to energy labelling of residential ventilation units. (Text with EEA relevance) (2016/C 416/06)

COMMISSION DELEGATED REGULATION (EU) /... of

Delegated Regulation (EU) 1059/2010 of 28 September 2010 supplementing Directive 2010/30/EU with regard to energy labelling of household dishwashers

COMMISSION REGULATION (EU) No /.. of XXX

CE marking of noise barriers and foundations

Regulation 574_2014: Annex III CPR. and. Regulation 568_2014: Annex V CPR

WORKING DOCUMENT. Explanatory Notes. Rationale of the draft regulation. Scope

ECOS Position Paper: Further recommendations

COMMISSION DELEGATED REGULATION (EU) /... of XXX

COMMISSION DELEGATED REGULATION (EU) /... of XXX

BUSINESS PLAN CEN/TC 49 GAS COOKING APPLIANCES EXECUTIVE SUMMARY

Council of the European Union Brussels, 14 July 2014 (OR. en)

Implementation of the Construction Products Regulation (CPR) in harmonized standards - Template for Annex ZA -

COMMISSION DELEGATED REGULATION (EU) No /.. of

The results of the impact assessment and of the workshop will be considered in the final proposal of the new directive.

2. SCOPE. OJ L 239, , p. 1. OJ L 239, , p. 83, OJ L 239, , p OJ L 239, , p. 162.

Working Document on a possible COMMISSION DELEGATED REGULATION

Working Document on a Draft. COMMISSION DELEGATED REGULATION (EU) No /.. of XXX

(Non-legislative acts) REGULATIONS

BUSINESS PLAN CEN/TC 142 WOODWORKING MACHINES SAFETY EXECUTIVE SUMMARY

EFCEM represents over 650 companies who supply commercial catering equipment to the European and International Foodservice industry.

Using consumer appliances in Europe the consumer view

COMMISSION DELEGATED REGULATION (EU) /... of

Mandate M/118 WASTE WATER ENGINEERING PRODUCTS

PART I ENERGY EFFICIENCY ACQUIS / DELEGATED REGULATION (EU) 811/2013

Proposal for a REGULATION OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL. on appliances burning gaseous fuels. (Text with EEA relevance)

EUROPEAN COMMISSION INDUSTRY AND ENTERPRISES DIRECTORATE-GENERAL AMENDMENT TO :

Both regulations are due to be reviewed by Key topics to be assessed during the reviews include:

COMMISSION REGULATION (EU) / of XXX

Product Testing. Vacuum cleaner ecodesign and energy labeling requirements EU 665/2013 & EU 666/2013

Information for installers. Simple to install, simply ready for the future. Wilo-Yonos PICO, Wilo-Stratos PICO, Wilo-Stratos, Wilo-Yonos MAXO.

ANNEXES. to the. Commission Delegated Regulation

Nordsyn energy labelling requirements for packages of water heaters and solar devices

INTERNATIONAL STANDARD

BUSINESS PLAN CEN/TC 250 STRUCTURAL EUROCODES EXECUTIVE SUMMARY

BUSINESS PLAN CEN/TC 164 WATER SUPPLY EXECUTIVE SUMMARY

This document is a preview generated by EVS

HARMONISATION STATUS OF SELECTED ELECTRICAL AND NON-ELECTRICAL Ex STANDARDS MARCH 2018

Vented (fresh air is heated, passed through textiles and exhausted from the appliance) Washer dryers are excluded from the analysis.

BUSINESS PLAN CEN/TC 305 POTENTIALLY EXPLOSIVE ATMOSPHERES EXPLOSION PREVENTION AND PROTECTION EXECUTIVE SUMMARY

Guidance from the Group of Notified Bodies for the Construction Products Regulation 305/2011/EU

The intention is to give to the implementing measures the form of two directly applicable regulations.

ON A POSSIBLE COMMISSION DIRECTIVE IMPLEMENTING COUNCIL DIRECTIVE 92/75/EC WITH REGARD TO HOUSEHOLD REFRIGERATING APPLIANCES.

EUROPEAN UNION. Brussels, 13 February 2014 (OR. en) 2011/0357 (COD) PE-CONS 54/13 ENT 190 MI 550 CONSOM 128 COMPET 470 CODEC 1481

High-efficiency circulating pumps Heating Air conditioning 50 Hz

WP2 European Product Analysis, Task 2.1 Determining energy efficiency criteria, D 2.1 Periodic Criteria Papers (first set)

Circulation Pump Optima

Implementing the Construction Products Regulation (EU) 305/2011

CONSUMER ORGANISATIONS COMMENTS ON ECODESIGN AND ENERGY LABELLING FOR DISHWASHERS

EUROPEAN COMMISSION DIRECTORATE-GENERAL FOR HEALTH AND FOOD SAFETY

WP2 European Product Analysis, Task 2.1 Determining energy efficiency criteria, D 2.1 Periodic Criteria Papers (first set)

The New EU-Regulation on Construction Products

COMMISSION DELEGATED REGULATION (EU) /... of XXX

Transcription:

WORKING DOCUMT ON A OSSIBLE COMMISSION REGULATION AMDING COMMISSION REGULATION (EC) No 641/2009 of 22 July 2009 with regard to ecodesign requirements for glandless standalone circulators and glandless circulators integrated in products Article 7 of Commission Regulation 641/2009/EC foresees that: ''The Commission shall review the methodology for calculating the energy efficiency index set out in Annex II, point 2 to this Regulation, for glandless circulators integrated in products before 1 January 2012.'' For these purposes, the European Commission issued a Mandate M469. A Europump (European ump Manufacturer Association) Working Group was formed under the Europump Standards Commission in order to deliver the technical basis for necessary standardisation work. The WG consisted of European circulator, boiler and heat pump manufacturers with consultation of the European eating Industry (EI), European eat ump Association (EA) and European Solar Thermal Industry Federation (ESTIF). Based on the finalised Working Document of the WG, C/TC197/WG1 developed a pre-standard consisting of three parts: umps Rotodynamic pumps Glandless circulators art 1: General requirements and procedures for testing and calculation of energy efficiency index (EEI), C work item WI0197081; umps Rotodynamic pumps Glandless circulators art 2: Calculation of energy efficiency index (EEI) for standalone circulators, C work item WI0197082; umps Rotodynamic pumps Glandless circulators art 3: Energy efficiency index (EEI) for circulators integrated in products, C work item WI0197083. C is about to issue a pr standard. The final measurement standard will be harmonised for the purposes of the Commission Regulation 641/2009/EC. In conjunction with the development of the efficiency calculation and measurement method for circulators integrated in products, Europump brought to the attention of the Commission the fact that the wording of the Regulation leaves an unintended loophole for a large number of non-complying circulators without pump housing to enter the market. EXLANATORY NOTE I. Loophole in the COMMISSION REGULATION (EC) No 641/2009 of 22 July 2009 with regard to ecodesign requirements for glandless standalone circulators and glandless circulators integrated in products Regulation 641/2009/EC sets minimum energy efficiency and information requirements on circulators. The Regulation 641/29009/EC specifies a 'circulator' as being 'an impeller pump, which has the rated hydraulic output power of between 1 W and 2500 W and is designed for use in central heating systems or in secondary circuits of cooling distribution systems'. A circulator is composed of two main parts, one part which consist of the motor, motor control

(or terminal box) and the impeller, a second part which is the pump housing. The pump housing is a casting that includes the volute (outer part) of the pump, which is connected to the pipework of a heating or secondary circuit of a cooling distribution system. The Regulation does not specify whether circulators placed on the market without pump housing are covered or not despite the initial intention of the Regulation. This matter, having been initially thought to be more critical for circulators integrated in products, is tackled in Article 1, point 2(b) of the Regulation. Standalone circulators without pump housing intended to be incorporated into old circulator pump housings in the installed base would not be subject to ecodesign requirements. This would risk creating a large artificial replacement-market of standalone circulators. II. Necessity to close the loophole The 'repair market' 1 for circulators without pump housing is estimated at 200 000-300 000 per year. The placing on the market of circulators with pump housing is estimated at 14 million per year. Out of these sales, 75 are via the replacement 2 market on the installed basis of 140 million circulators. Article 1, point 2(b), gives a timeframe of five years for manufacturers to place on the market circulators intended to be incorporated into products after the coming into force of the requirements. This time period was necessary for boiler manufacturers to redesign boilers to fit with the new high-efficiency circulators. Since the adoption of Regulation 641/2009/EC, the industry has identified that some individual manufacturers have the intention of using the replacement market as a loophole for sales of non-compliant low-efficiency standalone circulators without pump housing. Currently, due to the loophole identified by the industry, individual manufacturers are not yet making the necessary investments for the production of high-efficiency circulators in the fear of not getting a return to their investments. This would undermine the objective of the Regulation in leaving the sales of an estimated 75 of standalone circulators out of the scope of the Regulation. Thus, beyond the revision foreseen in Article 7 of the Regulation, it is necessary to amend the Regulation to cover an unintended loophole to avoid losing a major part of the expected savings. III. roposed solution to close the loophole After preparatory work during 2010 between Europump manufacturers and the Commission services, Europump made (on 23 March 2011) a final suggestion for an amendment to the Regulation to clarify some of the provisions of the Regulation. Europump's proposals (I-V) are as follows (for Europump proposal, see Annex): (I) Modify the definition of circulators in Article 1 by adding: "circulator" means an impeller pump, with or without pump housing, and; 1 Market solely for spares for existing circulators where the circulator without pump housing has failed. 2 Market of new circulators replacing old circulators in the installed basis.

(II) add a new definition of 'pump housing' in Article 1. It is suggested to implement the industry proposal in Article 2, points 3 and 6, by modifying the definition on ''standalone circulators'' and by adding a new definition of 'pump housing', as indicated below. When the loophole is closed, manufacturers will be able to be assured that there is a return to investments for the production of high-efficiency standalone circulators. Article 2 Definitions In addition to the definitions set out in Article 2 of Directive 2005/32/EC, the following definitions shall apply: (1) "circulator" means an impeller pump, which has the rated hydraulic output power of between 1 W and 2500 W and is designed for use in heating systems or in secondary circuits of cooling distribution systems; (2) "glandless circulator" means a circulator with the shaft of the motor directly coupled to the impeller and the motor immersed in the pumped medium; (3) "standalone circulator" means a circulator, with or without ''pump housing'', designed to operate independently from the product; (4) "product" means an appliance that generates and/or transfers heat; (5) "drinking water circulator" means a circulator specifically designed to be used in the recirculation of drinking water as defined in Council Directive 98/83/EC; (6) pump housing means the part of an impeller pump which is intended to be connected to the pipework of the heating system or secondary circuit of the cooling distribution system. A practical outcome of the above change is that when repairing: standalone circulators placed on the market before 1 January 2013 and; circulators integrated into products placed on the market before 1 January 2020. it is ensured that these are replaced with high-efficient circulators, with or without pump housing, that comply with the requirements of the Regulation. If a standalone circulator fails during the guarantee period, the manufacturer would have to replace the old low-efficiency circulator with a high-efficiency circulator, with or without pump housing, which has to comply with the requirements of the Regulation. (III) In line with the modifications proposed above, add clarification on the measurement method at the beginning of the Annex II of the Regulation. It is suggested to add the clarification as suggested and as indicated below.

Standalone circulators with pump housing shall be measured as a complete unit; Standalone circulators without pump housing shall be measured with the pump housing type in which they are intended to be used; The above specifies the way to measure the efficiency of standalone circulators with and without pump housing. Circulators integrated in products shall be dismantled from the product and measured with a erence pump housing; Circulators without pump housing intended to be integrated in a product shall be measured with a erence pump housing; where erence pump housing means a pump housing supplied by the manufacturer with inlet and outlet ports on the same axis and designed to be connected to the pipework of a heating system or cooling distribution system. The above specifies the way to measure the efficiency of circulators with and without pump housing. For these purposes, a definition on the erence pump housing is necessary. (IV) In line with Article 7 of Regulation 641/2009/EC, add specifications on the measurement of the efficiency of circulators integrated in products as follows. oint 2(6) of Annex II: add specification as follows, including a definition and a graph on 'system curve': For circulators integrated in products follow the erence control curve by adjusting the system curve and speed of the circulator. System curve means a relationship between flow and head ( = f() resulting from friction in the heating system or cooling distribution system, as presented graphically below.

max System curve n 100, 100 0, 100 2 n i i The above specifies the way to measure the efficiency of circulators integrated in products in line with Article 7 of Regulation 641/2009/EC. A graphical presentation of the system curve will ensure proper implementation of the efficiency measurement. oint 2(9) of Annex II: specify the energy efficiency index for standalone circulators and for circulators integrated in products as follows. For circulators, calculate the energy efficiency index 3 as: L, avg EEI = C20, where C20 = 0.49 The above specifies the way to measure the efficiency of circulators integrated in products in line with Article 7 of Regulation 641/2009/EC. Except for circulators integrated in products designed for primary circuits of thermal solar systems and for heat pumps, where the energy efficiency index is calculated as: 3 CXX means a scaling factor that ensures that at the time of defining the scaling factor only XX of circulators of a certain type have an EEI 0.20.

EEI = 1,36 3,8 30 n q L, avg C20 (1 e where C 20 =0,49 and n q is the specific speed defined as ) The above equation includes a 'compensation factor shown in the below graph. The objective is to create a function which asymptotically converges toward 0,49 which is the calibration factor for standalone circulators. A typical circulator for thermal solar and heat pump application has an nq between 15 and 20. A circulator with a low nq with the same high-efficiency motor as a standalone, would not meet the requirement without an nq compensation. With the compensation, also circulators used in thermal solar and heat pump applications will be able to meet the minimum efficiency requirements introduced on 1 August 2015. Without this calibration factor, these circulators would have to be oversized in order to comply with the requirements, leading to higher energy consumption. EEI Calibration 0,60 0,50 C 0,40 0,30 roduct integrated 0,20 Standalone 0,10 0,00 10 15 20 25 30 35 40 nq n q n = 60 0,75, where n q is specific speed of a circulator;

n is rotational speed in r.p.m. in this instance defined at and. (V) To ensure that the maintained circulators comply with the efficiency requirements in Annex I of the Regulation, add as follows: In case of maintenance of a circulator out of warranty the maintained circulator shall comply with the Energy Efficiency Requirements set out in sub-clause (1.) and (2.). In case of maintenance of a circulator non compliant with this regulation, it has to be replaced by a circulator including pump housing complying with this regulation. It is not suggested to implement the industry proposal as indicated above. As to the first proposed requirement in point (V), all circulators would be included, also those regulated in Article 1, point 2(b). On standalone circulators, the above requirement is not necessary as all circulators, with or without pump housing, are already covered with the modifications suggested under point (I) above; low-efficiency circulators, with or without pump housing, are banned from the 'replacement/maintenance' market on 1 January 2013. As to the second proposed requirement in point (V), circulators integrated into products are already covered in Article 1, point 2(b). On standalone circulators, the above requirement is not necessary as low-efficiency circulators, with or without pump housing, whether for the purposes of placing on the market or for maintenance, will have to comply with the requirement of the Regulation on 1 January 2013 onwards. The proposed amendments aim at clarifying the wording of the Regulation and thus guaranteeing that the expected savings from the Regulation are realised. This will ensure that harmonised ecodesign requirements apply for all circulators across the EU promoting their free movement within the internal market, regardless of whether the circulators are standalone or integrated in products, or with or without pump housing. Additionally, the draft Mandate on circulators and the r standard integrate these changes. IV. Timing of the implementation of the solution It is intended to launch the consultation of the Commission's internal services on the amendment of the Regulation on 23 May 2011. In order to be able to keep to this deadline, the members of the Ecodesign Consultation Forum are asked to provide their comments to the Commission on this explanatory note and the attached draft on elements amending the Regulation in four weeks counting from the receipt of these documents. Annexes: - Annex to amendments proposed to the Commission Regulation (EC) No 641/2009 - Europump request to amend Regulation 641/2009/EC

Annex to AMDMTS ROOSED TO TE REGULATION COMMISSION REGULATION (EC) No 641/2009 of 22 July 2009 implementing Directive 2005/32/EC of the European arliament and of the Council with regard to ecodesign requirements for glandless standalone circulators and glandless circulators integrated in products Article 2 Definitions In addition to the definitions set out in Article 2 of Directive 2005/32/EC, the following definitions shall apply: (1) "circulator" means an impeller pump, which has the rated hydraulic output power of between 1 W and 2500 W and is designed for use in heating systems or in secondary circuits of cooling distribution systems; (2) "glandless circulator" means a circulator with the shaft of the motor directly coupled to the impeller and the motor immersed in the pumped medium; (3) "standalone circulator" means a circulator, with or without ''pump housing'', designed to operate independently from the product; (4) "product" means an appliance that generates and/or transfers heat; (5) "drinking water circulator" means a circulator specifically designed to be used in the recirculation of drinking water as defined in Council Directive 98/83/EC; (6) pump housing means the part of an impeller pump which is intended to be connected to the pipework of the heating systems or secondary circuits of cooling distribution system. ANNEX II Measurement methods and methodology for calculating the energy efficiency index 1. MEASUREMT METODS For the purposes of compliance and verification of compliance with the requirements of this Regulation, measurements shall be made using a reliable, accurate and reproducible measurement procedure that takes into account the generally recognised state of the art measurement methods, including methods set out in documents the erence numbers of which have been published for that purpose in the Official Journal of the European Union. 2. METODOLOGY FOR CALCULATING TE ERGY EFFICICY INDEX The methodology for calculating the energy efficiency index (EEI) for circulators is as follows:

Standalone circulators with pump housing shall be measured as a complete unit; Standalone circulators without pump housing shall be measured with the pump housing type in which they are intended to be used; Circulators integrated in products shall be dismantled from the product and measured with a erence pump housing; Circulators without pump housing intended to be integrated in a product shall be measured with a erence pump housing; where erence pump housing means a pump housing supplied by the manufacturer with inlet and outlet ports on the same axis and designed to be connected to the pipework of a heating system or secondary circuit of a cooling distribution system. 1. Where a circulator has more than one setting of head and flow, measure the circulator at the maximum setting. ead () means head (in metres) produced by the circulator at the specified point of operation. Flow () means the volume flow rate of water through the circulator (m 3 /hr). 2. Find the point where is maximum and define the flow and head at this point as: and 100. 3. Calculate the hydraulic power hyd at this point. ydraulic power means an expression of the arithmetic product of the flow (), ead () and a constant. hyd means hydraulic power delivered by the circulator to the fluid being pumped at the specified point of operation (in watts). 4. Calculate the erence power as: 0.3 hyd ( 1 e ), 1W 2500W = 1.7 + 17 hyd hyd Reference power means a relation between hydraulic power and power consumption of a circulator, taking into account the dependency between circulator efficiency and size. means the erence power consumption (in watts) of the circulator. 5. Define the erence control curve as the straight line between the points:, ) and 0, 2 (

max 100, 2 100 0, 25 50 75 6. Select a setting of the circulator ensuring that the circulator on the selected curve reaches = max point. For circulators integrated in products follow the erence control curve by adjusting the system curve and speed of the circulator. System curve means a relationship between flow and head ( = f() resulting from friction in the heating system or cooling distribution system, as presented graphically below. max System curve n 100, 100 0, 100 2 n i i 7. Measure 1 and at the flows:, 0.75, 0.5, 0. 25 1 means the electrical power (in watts) consumed by the circulator at the specified point of operation. 8. Calculate at these flows.

L = meas 1, meas, if meas L = 1, meas, if meas > where is the head on the erence control curve at the different flows. 9. Using L and this load profile: Flow [] 100 75 50 25 Time [] 6 15 35 44 max L avg Calculate the weighted average power, as: 25 50 75 L,avg = 0.06 L, + 0.15 L,75 + 0.35 L, 50 + 0.44 L,25 For standalone circulators, calculate the energy efficiency index 4 as: L, avg EEI = C20, where C20 = 0.49 Except for circulators integrated in products designed for primary circuits of thermal solar systems and for heat pumps, where the energy efficiency index is calculated as: EEI = 1,36 3,8 30 n q L, avg C20 (1 e where C 20 =0,49 and n q is the specific speed defined as ) n q n = 60 0,75 4 CXX means a scaling factor that ensures that at the time of defining the scaling factor only XX of circulators of a certain type have an EEI 0.20.

where n q is specific speed of a circulator; n is rotational speed in r.p.m. in this instance defined at and.

0