NANEO EMC-M WALL-HUNG GAS CONDENSING BOILERS

Similar documents
PMC-M WALL-HUNG GAS CONDENSING BOILERS

NANEO EMC-M EASYLIFE WALL-HUNG GAS CONDENSING BOILERS

WALL-HUNG GAS CONDENSING BOILERS MCR-P 24/28 BIC. HOMOLOGATION B 23P - C 13x - C 33x - C 93x -C 53 - C 43x - C 83x *

ZENA PLUS EASYLIFE WALL-HUNG GAS BOILERS

MPX 24/28 MI Compact MPX 28/33 MI Compact CONDITIONS OF USE HOMOLOGATION. B 23 - C 13x - C 33x - C 53x - C 93x - C 83x* B 23p - B 33 - C 43x

4FLOOR-STANDING GAS CONDENSING BOILERS

FLOOR STANDING GAS CONDENSING BOILERS CONDITION OF USE CLASSIFICATION

FLOOR-STANDING GAS CONDENSING BOILERS FROM 3.4 TO 35.9KW. by 160 litre enamelled calorifier with coil placed CONDITIONS OF USE HOMOLOGATION

PRODUCT CATALOGUE

8FUEL OIL CONDENSING BOILERS

GTU C 220 FUEL OIL CONDENSING BOILERS

GT 220 PROJECT CAST IRON FLOOR-STANDING FUEL OIL-/GAS-FIRED BOILERS

MCR 24 MCR 24/28 MI MCR 30/35 MI MCR 34/39 MI

EMC-M 24 EMC-M 24/28 MI EMC-M 30/35 MI EMC-M 34/39 MI

ADVANCE EASYLIFE PROJECT

WHE 2.24 / WHE 2.24 FF

GT 220 CAST IRON FLOOR-STANDING FUEL OIL- / GAS-FIRED BOILERS

Superior. A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler. Outputs 120, 160, 200, 240, 280 kw

VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power

WALL HUNG GAS BOILER FOR C.H. AND PREDISPOSTION FOR INSTANTANEOUS D.H.W. PRODUCTION (with optional kit) MODELS 34,8 kw (depotenziata) 50 C

Vivadens. Wall-hung gas condensing boilers MCR 24/28 BIC. User Guide B

CALORA TOWER GAS 15S EX CALORA TOWER GAS 25S EX CALORA TOWER GAS 35S EX

Remeha. Fuel oil/gas boilers P 520. Installation and Service Manual A

1 VICTRIX ZEUS Superior kw I features

DIEMATIC VM isystem WALL-MOUNTED CONTROL SYSTEM. DIMENSIONS Length: 320 mm Height: 260 mm Depth: 130 mm. POWER SUPPLY 230 V, 50 Hz, 6 A

Ciao Green Condensing Wall-Hung Boilers

24/31-28/35-33/40 kw Premix System Condensing - ErP Combi Gas Boilers. Enerwa / EnerwaPlus.

FLOOR STANDING GAS CONDENSING BOILERS HOMOLOGATION C 630- ECO: B 23 - B 23P - C 33 - C 53 - C 63 - C 83 - C 93

Exclusive Green E Condensing Wall-Hung Boilers

Divacondens D Plus Atmospheric condensation wall-mounted boilers, with instant domestic hot water production

VICTRIX 50 1 SPECIFICATIONS. Wall mounted condensing boilers

VICTRIX Superior kw Export VICTRIX Superior kw X Export

GT 120 >> >> >> << >> Sustainable Comfort. Longlasting comfort

C ECO FLOOR STANDING GAS CONDENSING BOILER CONDITIONS OF USE HOMOLOGATION GAS CATEGORY

Power X High Power Condensing Wall-Hung Boilers

Clyde Alkon 90. Floor standing condensing boilers. Natural Gas. 90 kw. LP Gas. 90 kw

HIGH POWER. VICTRIX PRO 2 ErP. High power, wall-hung condensation boiler

SPECIFICATIONS - NIKE

Quinta Pro Range. The New Remeha. Condensing Boilers REMEHA QUINTA PRO RANGE. High efficiency wall hung condensing boiler with ultra low NOx emission

white blue cobalt bordeaux light oak (rovere)

Condensing, pre-mixed, wall-hung gas boilers with water tank

HPI REVERSIBLE AIR/WATER HEAT PUMPS SPLIT INVERTER

Power X High Power Condensing Wall-Hung Boilers

C Tahiti. condensing

Modulens G >> >> >> Condensing in excellence mode

Range GT GTU C GT 220

24/31-28/35-33/40 kw Premix System Condensing Combi Gas Boilers. Priwa / PriwaPlus.

Mynute Green k. Condensing Wall-Hung Boilers. Residential Heating

Ethos Range High Efficiency Domestic Boilers. Combination Boilers Condensing Combination Boilers Condensing System Boilers

Innovens Pro. Wall-hung gas condensing boilers MCA Installation and Service Manual A

ECONOFLAME R6000 GAS FIRED CONDENSING HOT WATER HEATER SUPPLEMENT

Wood-burning boiler CBB. User Guide E

ALEZIO REVERSIBLE AIR/WATER HEAT PUMPS SPLIT INVERTER CONDITIONS OF USE

24-28 kw Conventional Combi Gas Boiler. Lawa / LawaPlus

DTG Eco / V130

AVIO kw Export 1 FEATURES. Wall-mounted with storage tank

24/31-28/35-32/40 kw Premix System Condensing Combi Gas Boilers. Priwa / PriwaPlus

CITY PLUS. Wall-hung condensing boilers. ErP 24 HE 30 HE. Ready

MCR-P 24 MCR-P 24/28 MI MCR-P 30/35 MI MCR-P 34/39 MI

Flue gas condensation...

ACCUMULATION OF EUROPEAN CLASS

<< >> Condensing technology at the service of oil. Controlling energy to save money

>> >> >> High technology with oil. High performance modulating burner Compact boiler design. Compatible with renewable energies. Sustainable Comfort

Technical documentation. ComfortLine gas condensing boilers CGB-2(K) CGW-2 CGS-2 CSZ-2 NEW

Stokvis R600 LMS IP Water Heater Gas-Fired Floor Standing Condensing

Seradens Super Seradens Super Plus

2530C / 3035C / 3540C. Condensing ErP Boilers. Enerwa EnerwaPlus

AGUAdens TM 100% residential condensing D.H.W. wall-mounted water heaters ( litres) AISI 316 D.H.W. WORKING PRESSURE TITANIUM CONDENSING

WALL-HUNG HIGH EFFICIENCY GAS BOILERS. Elegant, efficient and intelligent

INDEPENDENT DOMESTIC CALORIFIERS

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

Mynute Green Condensing Wall-Hung Boilers

ENERGY TOP. Condensing boiler solutions

RinNOVA. User manual and installation instructions

Remeha. Fuel oil/gas boilers P 420. Installation and Service Manual

Room sealed circuit appliance sold without the terminal or the combustion air supply and exhausted gas ducts. TYPE C 63 TYPE B TYPE B 23

Euron. Compact Wall Mounted Gas Fired Condensing Boilers and Combis with Outputs 24kW - 30kW BOILERS

ALKON CARGO. A precise and fast delivery rate. A very high specific flow rate (20 litres per minute with Dt 25)

LIBRA DUAL INSTALLATION USE AND MAINTENANCE. Italian product. High quality IST 04 C

ALEZIO EVOLUTION EASYLIFE REVERSIBLE AIR/WATER HEAT PUMPS SPLIT INVERTER

Sirius FS. Working towards a cleaner future

CAST IRON PREMIX HIGH EFFICIENCY GAS FIRED BOILER kw BRILEY DESIGN MANUAL

BSC...E - BSP...E - BESC...E

Sirius WH. Working towards a cleaner future

C 330 ECO - C 630 ECO

Clyde CK40. Cast Iron Boiler. Engineering Data Sheet 663/8 May Natural gas Class D oil Dual Fuel. 350 kw to 500 kw

MODULAR GAS CONDENSING UNIT EQUIPPED WITH PRIMARY RING and premix modulating Low NO x. from 100 to 900 kw and in battery up to 8 units

Rinnova Cond X. User manual and installation instructions

TAHITI DUAL HC - HR INSTALLATION, USE AND MAINTENANCE. Italian product. High quality

So old fashioned... As the combustion chamber is completely room sealed, it does not release any smells and does not dirty.

SOLNEO SGC 24 SOL. User Guide. Gas fired condensing boiler C

BORA BORA. BORA gas: the best suns THE MODELS BORA GAS ALL INNOVATION STRENGTHS

wall-mounted boilers, water heaters and pool heaters from 15 kw to 140 kw

FCX FUEL OIL CONDENSING BOILER RANGE

Oil-fired condensing boiler GTU C 330. User Guide B

Remeha. Fuel oil/gas boilers P 320. Installation and Service Manual

HT V2 HT Split

GAS 610 ECO PRO. The new Remeha. Condensing Boiler Range REMEHA GAS 310/610 ECO PRO

Tower Green HE Hybrid

WELCOME TO REMEHA, THE EXPERT CHOICE INTRODUCING THE REMEHA GAS 110 ECO RANGE FEATURES AND BENEFITS

Transcription:

NANEO EMC-M WALL-HUNG GAS CONDENSING BOILERS EMC-M : from 6.1 to.8 kw, for heating only EMC-M /BS 8 and EMC-M /BS 13: from 6.1 to.8 kw, for heating and hot water preparation by associated DHW tank, 8 or 13 litres EMC-M MI: from 6.1 to 35.7 kw, for heating and instant domestic hot water production with output up to 37.8 kw in DHW mode EMC-M EMC-M MI EMC-M /BS 8 EMC-M /BS 13 EMC-M : for heating only EMC-M MI or EMC-M /BS Heating and domestic hot water by integrated, independent calorifier or micro-accumulated Condensing All natural gases Propane CE identification No.: 63CM319 Very compact boiler in an innovative design: 368 x 589 x 36 mm and extremely light. - Boiler fully equipped: delivered with its complete mounting frame; control panel with very easy to use essential functions that can be completed with various options enabling much broader installation parameters such as: modulating room temperature thermostats, service tool. - Equally suited to new installations and the replacement market thanks to the pipe kits available for our main competitors. - Various air/flue gas connection configurations are possible: we offer solutions for connection by horizontal or vertical forced flue, to a chimney, in twin pipe or to a shared flue system. CONDITIONS OF USE Boiler: Max. operating pressure: 3 bar Max. operating temperature: 9 C Safety thermostat: 11 C Power supply: 3 V/5 Hz Protection index: IPXD Domestic hot water: Max. operating pressure: 1 bar HOMOLOGATION B 3 - B 3P - B 33 - C 13x - C 33x - C 93x - C 53 - C 3x - C 83x GAS CATEGORY II ESi3P, NOx classification: 5 EASYLIFE

PRESENTATION EMC-M and EMC-M MI boilers are delivered fully assembled and factory tested. They come ready to operate on natural gas H; adaptable to propane thank service tool or modulating room thermostat (option). EMC-M boilers are factory fitted with a heating/dhw reversal valve for connection to an independent hot water calorifier: types of optional DHW calorifiers are available: - 8 litres BMR 8, calorifier to be juxtaposed to the right or the left of the boiler: version EMC-M /BS 8, - 13 litres SR 13 calorifier to be placed on the floor under the boiler: version EMC-M /BS 13. EMC-M MI are mixed boilers and produce large quantities of domestic hot water ( classification according to the standard EN 133) thanks to an oversized steel plate exchanger and very reactive electronics. HIGH LEVELS OF PERFORMANCE - Efficiency at 3% at 5/3 C up to 19,%. - Performance class CE. - NOx < 6 mg/kwh. - NOx classification: 5 according to pr EN 83. - Low noise level. STRONG POINTS - Wall-hung gas condensing boiler, fully preset. - Boiler of innovative design, very compact: 368 x 589 x 36 mm, extremely light: 5 kg, - Compact exchanger, molded cast alloy aluminium/ silicium high efficiency. - Air/gas module with gas burner, modulating from to 1% for a perfect adaptation of boiler output to actual needs, with non return valve to run with pressurised evacuation system, the central unit, the venturi, the fan with air intake silencer and the gas supply pipe. - Hydraulic module integrating the 1 speed heating pump (high efficiency EEI <,3 modulating pump as optional), the heating/dhw reversal valve, stainless steel plate exchanger for instant domestic hot water production by EMC-M MI, the 3 bar heating safety valve, the flow limiter, the flow detector for EMC-M MI - 8 litre expansion vessel integrated in the support frame, - Mounting frame with prefitted water and gas valves, disconnector (outlet and return valves, and disconnector in composite materiel), mechanical manometer, flow collector and connecting pipes kit. - Removable control panel, located under the boiler, can be deported to the wall, connected to the central unit by BUS. Easy to use, it allows a basic setting via buttons heating and DHW temperatures. Other parameters can be set through modulating room thermostats and service tool, see page 6. - Various horizontal or vertical air/flue gas connections (homologation C 13x and C 33x ), twin pipe adapter (homologation C 53 ), or shared flue (homologation C 3x ) are available as options, see page 1. MODELS AVAILABLE Model Boiler Calorifier HR 56 Boiler/ Calorifier connection kit DHW sensor Output (kw) (heating mode) at 5/3 C at 8/6 C Output (kw) (DHW mode) NANEO_Q5 EMC-M For heating only - - - 6.1 -.8 5.5-3. - NANEO_Q3 EMC-M /BS 8 For heating and DWH by 8 litres calorifier to be placed at the right or at left of the boiler HR 56 EE 53 HR 93 AD 6 + + + 6.1 -.8 5.5-3. 5.5 -.6 NANEO_Q33 EMC-M /BS 13 For heating and DWH by 13 litres calorifier to be placed under the boiler HR 56 EE HR 9 AD 6 + + + 6.1 -.8 5.5-3. 5.5 -.5 NANEO_Q5 EMC-M /8 MI EMC-M 3/35 MI EMC-M 3/39 MI For heating and instant domestic hot water production HR 57 HR 58 HR 59 - - - 6.1 -.8 8.5-31. 8.5-35.7 5.5-3. 7.7-9. 7.7-33.8 5.5-7.5 7.7-33.9 7.7-37.8

TECHNICAL SPECIFICATIONS DESCRIPTION EMC-M MI Delivered mounting frame Flue gas evacuation Air vent Ignition and ionisation electrodes Exchanger in cast aluminium/ silicium alloy with complete premixing stainless steel burner, modulating from to 1% output Mounting frame with integrated expansion tank 3 bar heating safety valve Plate exchanger with large exchange surface for the production of micro-storage DHW (EMC-M...MI only) Air/gas module Heating/ DHW reversal valve NANEO_Q8A Heating circulator 1 speed Control panel (see page 6) Thermo-manometer Foldable mounting frame Prefitted water and gas valves including the disconnector NANEO_Q1A View of the underneath of the boiler Air/gas module Safety valve run off Gas burner modulating from to 1% output Air/gas unit Fan Connection points for the «water and gas valve» PCB Condensates evacuation siphon Air intake silencer NANEO_Q7 Expansion tank Support frame NANEO_Q3 Gas safety unit Venturi 3

5 1 C 1 3 1 1 bar ON OFF AU T 5 1 C 1 bar 3 1 1 ON OFF AU T 5 1 C 1 bar 3 1 1 ON OFF AU T TECHNICAL SPECIFICATIONS MAIN DIMENSIONS (IN MM AND INCHES) EMC-M EMC-M MI 18 EMC-M /BS 8 36 3 9 3 9 368 368 3 9 51 75 66 55 6 8 55 6 8 6 6 maxi 176,5 51 75 66 68 88 187 7 6 35 5 1 3 5 7 117 18 51 316 NANEO_F1B 6 35 1 5 18 316 3 5 Ø 6 Ø 7 1 11 187 19 1 11 NANEO_F3D EMC-M /BS 13 368 3 9 55 6 8 51 75 66 6 35 5 1 3 5 18 316 1 11 6 8 11 153 35 91 59 Ø 57 NANEO_FD Heating flow Ø 18 mm interior EMC-M : primary tank outlet Ø 16 mm interior (if exist) EMC-M MI: DHW outlet Ø 16 mm interior Gas inlet Ø 18 mm interior EMC-M : primary tank return Ø 16 mm interior (if exist) EMC-M MI: domestic cold water inlet Ø 16 mm interior Heating return Ø 18 mm interior Safety valve outlet pipe Ø 15 mm Condensates drain Ø 5 mm Evacuation of combustion products and air inlet pipe Ø 6/1 mm EMC-M /BS: DHW outlet R 3/ EMC-M /BS: domestic cold water inlet R 3/

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATION Boiler Boiler type: condensing Burner: modulating with complete premixing Boiler specifications Energy used: natural gas or propane Combustion evacuation: chimney or sealed Min. flow temperature: 3 C Model EMC-M /BS 8 /BS 13 /8 MI 3/35 MI 3/39 MI Heating Type generator and DHW Heating Heating and DHW with additional storage of production with only < 1 litres integrated in the secondary circuit separate DHW tank Useful output at 5/3 C Pn (heating mode) kw 6.1-.8 6.1-.8 6.1-.8 8.5-31. 8.5-35.7 Nominal output at 8/6 C (DHW mode) kw - - 7.5 33.9 37.8 Efficiency at % 1% Pn at average temp. 7 C % 97.6 97.6 97.6 97. 96.9 outout and C 1% Pn at return temp. 3 C % 13.3 13.3 13.3 13.3 1. water temperatur 3% Pn at return temp. 3 C % 19. 19. 19. 18.8 18.8 Nominal water flow at Pn, Δt = K m3/h 1.3 1.3 1.3 1.5 1.5 Min. - max. useful output at 8/6 C (heating mode) kw 5.5-3. 5.5-3. 5.5-3. 7.7-9. 7.7-33.8 Manometric height available heating circuit at Pn mbar 75 75 17 317 187 Water content l 1. 1. 1.6 1.7 1.7 Gas flow at Pn - natural gas H/L m 3 /h.5/.95.5/.95.98/3.7 3.68/.8.13/.8 (15 C, 113 mbar) - propane m 3 /h.98.98 1.15 1. 1.6 Flue gas temperature at 8/6 C C 78 78 8 8 86 Min. - max. flue gas mass flowrate kg/h 9.-38.7 9.-38.7 9.-5.5 13.1-56.3 13.1-6.9 Flue gas pressure available Pa 8 8 116 15 1 Stand-by losses at Δt = 3 K W 35 35 35 5 5 Auxiliary electrical power (ex. heating pump) at Pn W 7 61 Electrical power heating pump (1) W 77 77 65 83 8 Electrical power at zero load W 3 3 3 3 3 Acoustic power level at nominal output db(a) 7, 7, 7, 7, 9,7 Net weight kg 5 75/95 6 9 9 (1) One speed circulating pump Domestic hot water specifications Model EMC-M /BS 8 /BS 13 /8 MI 3/35 MI 3/39 MI DHW calorifier capacity l 8 13 - - - Exchanged power kw.6.5 7.5 33.9 37.8 Flow per hour at Δt = 35 K l/h 55 (1) 56 (1) - - - Flow over 1 min at Δt = 3 K l/1 min 16 () 1 () - - - Spec. flow at Δt = 3 K (compliance with EN 133-1) l/min 16. () () 1 17 19 Cooling constant Wh/h.l.K. N.C..7 - - - DHW losses through the outer casing at Δt = 5 K W N.C. 73 - - - Auxiliary electrical power in DHW mode W 117 117 117 15 159 (1) Domestic performance at room temp.: C, cold water temp.: 1 C, primary hot water temp.: 8 C. () Domestic performance at room temp.: C, cold water temp.: 1 C, primary hot water temp.: 85 C, storage temp.: 6 C. 5

CONTROL PANEL NANEO CONTROL PANEL The control panel fitted to NANEO boilers is very easy to use. It is detachable: located under the boiler, it can also be mounted on the wall. As standard, it enables basic settings to be made using the buttons to set the heating and DHW temperatures. Two keys Reset and Chimney Sweep with display LED complete the unit. Other parameters can be set using a service tool (such as the setting of the heating gradient, the maximum boiler temperature, etc. see p. 8) or a modulating room temperature thermostat (options below). A control system option according to the room temperature and/ or the outside temperature is also available: see below. NANEO_Q31 DHW temperature setting button Heating temperature setting button Chimney Sweep key with LED status display Reset key with LED status display NANEO CONTROL PANEL OPTIONS AD 1 AD 881Q3 8666Q1A Programmable room thermostat (wire) - Package AD 137 Programmable room thermostat (wireless) - Package AD Non programmable room thermostat - Package AD 1 The programmable thermostats handle the control and weekly programming of the heating by activating the burner in accordance with the various operating modes: Automatic according to the programme, Permanent at a set temperature or Holidays. The wireless versions are delivered with a receiver box to be affixed to the wall close to the boiler. The non-programmable thermostat is used to regulate the room temperature according to the instruction given by activating the burner. AD 91 AD 9 isense_q3 isense_q Modulating room thermostat Opentherm (wire) - Package AD 91 Modulating room thermostat Opentherm (wireless) - Package AD 9 This thermostats handles the regulation and programming of the heating and of DHW. They include adjustment parameters for the NANEO boiler: heating curve maxi temperature boiler, fan speed, The regulator adapts the power boiler to the needs. 3 modes of operating are possible: AUTOMATIC: according the weekly programming used: for each programmed period, we can indicate the set temperature. PERMANENT: maintains the set temperature chosen for the day, night or antifreeze. VACATION: intended for absences of long duration. Allows to bring in the dates of beginning and end of the vacation as well as the desired temperature. For operation according to the outside temperature, a outside sensor (package FM 6) can be added. The version «wireless» is delivered with a transmitter-receiver to be fixed to the wall near the boiler. 6

CONTROL PANEL NANEO CONTROL PANEL OPTIONS (CONTINUATION) Outside temperature sensor - Package FM 6 The outside sensor can be used alone or in combination with romm thermostat 8575Q3 MCR_Q18 Domestic hot water sensor - Package AD 6 The domestic hot water sensor is used to apply priority regulation to DHW production by an independent tank. CMIX_Q1 Module to control circuits - Package AD 9 Works only in combination with one or two modulating room thermostat «OpenTherm», enables to control and modulate a direct circuit and a circuit with mixing valve or circuits with mixing valve. It is delivered with a flow sensor for each circuit, an outside sensor and a supply cable. The boiler / module connection is made with an «OpenTherm» BUS cable. HYDRAULIC ACCESSORIES Below the list of hydraulic connection accessories to be ordered in the following cases: NEW INSTALLATION Standard Nota: - For EMC-M boilers, hydraulic connection accessories: mounting frame with water and gas connection pipes are delivered with the boiler Option: Pipe cover: package HR 7 Provides a neat finish underneath the boiler With rising column Package to order: EMC-M and EMC-M MI: Height adjustment frame: Package HR 79 Hydraulic connection pipe for height adjustment frame: Package HR 8 NANEO_Q1 NANEO_Q17 NANEO_Q REPLACING AN EXISTING BOILER ( ONLI CONCERNS EMC-M MI) Package to order when replace existing boiler Option: Pipe cover: package HR 73 Hydraulic connection pipe (water and gas) to be screwed: Package HX 17 NANEO_Q1 MS_Q7 7

BOILERS OPTIONS NANEO_Q11 NANEO_Q5 Solar kit with thermostatic mixing valve - Package HR 8 Enables connection of a solar DHW tank to an EMC-M MI boiler. When domestic hot water is drawn off, the boiler will provide the additional temperature to satisfy the set point. Cleaning tool boiler body - Package HR 81 Connects to a classic vacuum cleaner and allows an easy boiler body cleaning. Cleaning tool plate exchanger - Package HR 8 For EMC-M MI only. 8531Q7 8531Q8A 8 To replace the 1-speed heating pump fitted to NANEO boilers as standard. Flue gas temperature sensor kit - Package HR 71 Shuts down the boiler when the flue gas temperature exceeds 11 C. HC 33 HC 3 Service tool - Package HR 83 This tool, at the disposal of the installer, is necessary - The maximum boiler temperature; whenever it comes to setting installation parameters - The fan speed; different from the factory settings. - etc. It can be used, for example, to modify the settings if It can also be used to help with troubleshooting by the gas type is changed or to modify: displaying an error code. - The installation s heating gradient; High efficiency modulating heating pump - Package HR 78 NANEO_Q NANEO_Q35 NANEO_Q7 NANEO_Q6 8666Q3 NANEO_Q37 HR 9 SR 13 Calorifier BMR 8 - Package EE 53 Connection kit BMR 8/EMC-M - Package HR 93 Calorifier SR 13 - Package EE Connection kit SR 13/EMC-M - Package HR 9 BMR 8 and SR 13 domestic hot water tanks are The specifications of these tanks in combination with high performance tanks. They are protected by a EMC boilers are given on page 5. lining in food quality standard high quartz content The boiler/tank connection kits available include vitrified enamel and a magnesium anode. rigid and/or flexible connection pipes between the boiler and the tank. Condensate neutralisation tank - Package HC 33 Wall bracket for neutralisation tank - Package HC 3 Granule refill for neutralisation tank - Package HC 35 The materials used for the condensates flow effectiveness of the granules by measuring the pipes must be appropriate; otherwise the ph is necessary. If need be, the granules must be condensates must be neutralised. An annual check replaced. of the neutralisation system and particularly the NANEO_F15 NANEO_Q36 HR 93 MCR_Q1 BMR 8

BOILERS OPTIONS AIR/FLUE GAS CONNECTION TO BOILER NANEO EMC-M The EMC-M... boilers can be connected to: - a horizontal wall terminal PPS Ø 6/1 mm (package DY 871) - configuration C 13x, - a vertical terminal PPS Ø 8/15 mm, black (package DY 83) or red (DY 8) + adapter (package HR 68) - configuration C 33x, DY 871 DY 8 - it is also possible to connect the boiler to a chimney (configuration B 3p or C 93x ), in twin pipe (configuration C 53 ) or to a shared flue system (configuration C 3x ). All these flue systems must be ordered separately. Horizontal wall terminal PPS Ø 6/1 mm with inspection elbow - Package DY 871 Vertical terminal PPS Ø 8/15 mm - Package DY 8 (red) o DY 83 (black) MCX_F7B NANEO_Q3A MC35E_F51A Horizontal wall terminal PPS Ø 6/1 mm without elbow - Package DY 9 MCX_F8 NANEO_Q1 Connecting kit for shared flue system - Package DY 91 If connected to a collective duct, the adapter Ø 6/1 mm delivered with the boiler should be removed and replaced by package DY 91 presented opposite, which incorporates the adapter Twin pipe adapter - Package HR 7 For connection with separate air and flue gas pipes (C 53). Ø 8/15 mm as standard. To determine the position of the connection to the shared flue system, see diagram on the next page. NANEO_Q8 NANEO_Q9 Adapter low profile for horizontal forced flue - Package HR 67 Allows a height saving of 66 mm. Flue gas adapter Ø 8/15 mm - Package HR 68 Is fitted instead and in the place of the Ø 6/1 mm fitting delivered mounted on the boiler. 9

INFORMATIONS REQUIRED FOR INSTALLATION STATUTORY INSTRUCTIONS ON INSTALLATION AND MAINTENANCE The installation and maintenance of the appliance in both be carried out by a qualified professional in compliance with the residential buildings and establishments open to the public must statutory texts of the codes of practice in force. LOCATION NANEO condensing boilers must be installed in premises protected from frost, which can also be ventilate, they must in no event be installed above a heat source or a cooking appliance. The IPXD protection index enables them to be installed in kitchens and bathrooms, excluding protection volumes 1 and, however. The wall to which the boiler is secured must be capable of bearing the weight of the boiler when full of water. In order to ensure adequate accessibility around the boiler, particularly if the boiler is installed in a closed casing we recommend that you respect the minimum dimensions given opposite. Ventilation This must comply with prevailing regulations. min.6 5 1 min. 368 5 min. 5 55 NANEO_F9 min. 5 Connection to a shared flue system with kit DY 91 S 1 + S : - 6 cm (in configuration B 3P ) - 15 cm (in configuration C 13x, C 33x, C 93x, C 53 ) 18 NANEO_F1A In order to avoid damage to boilers, it is necessary to prevent the contamination of combustion air by chloride and/or fluoride compounds, which are particularly corrosive. These compounds are present, for example, in aerosol spray cans, paints, solvents, cleaning products, washing powders/ liquids, detergents, glues, snow clearing salts, etc. It is therefore necessary: - To avoid sucking in air discharged from premises using such products: hairdressers, dry cleaners, industrial premises (solvents), premises containing refrigeration systems (risk of leaking refrigeration fluid), etc. - To avoid the storage of such products close to boilers. Please note that, if the boiler and/or its peripherals become corroded by chloride and/or fluoride compounds, our contractual warranty cannot be invoked. GAS CONNECTION Comply with prevailing national or even local instructions and regulations. In all cases, a sectional valve is fitted as close as possible to the boiler. This valve is delivered prefitted to the hydraulic connection plate delivered with NANEO boilers. A gas filter must be fitted to the boiler inlet. ELECTRICAL CONNECTION This must comply with the prevailing standard. The boiler must be powered by an electrical circuit comprising a omnipole switch with an opening distance > 3 mm. Protect the connection to the mains with a 6 A fuse. Gas supply pressure: - mbar on natural gas H, 5 mbar on natural gas L, - 37 on propane. Notes: - The sensor cables must be separated from the 3 V circuits by at least 1 cm. - In order to protect the pump antifreeze and cleaning functions, we recommend not switching off the boiler at the mains switch. 1

INFORMATIONS REQUIRED FOR INSTALLATION HYDRAULIC CONNECTIONS Important: The principle of a condensing boiler is to recycle the energy contained in the water vapour in the combustion gases (latent vaporisation heat). Consequently, to achieve an annual operating efficiency in the order of 19%, it is necessary to Connection to the heating circuit NANEO boilers must only be used in closed circuit heating installations. The central heating systems must be cleaned to eliminate the debris (copper, strands, brazing flux) linked to the installation of the system and deposits that can cause malfunctions (noise in the system, chemical reaction between metals). More particularly, if fitting a boiler to an existing installation, it is strongly recommended that you clear sludge out of the system before installing the new boiler. size the heating surfaces in such a way as to obtain low return temperatures, below the dew point (e.g. underfloor heating, low temperature radiators, etc.) during the entire heating period. Furthermore, it is important to protect central heating installations against the risk of corrosion, scaling and microbiological growth by using a corrosion inhibitor adapted to all types of systems (steel, cast iron radiators, heated floor, PER). The water treatment products used must comply with regulations. Manometric height of the heating circulating pump fitted to NANEO boilers EMC-M EMC-M /8 MI 7 7 Manometric height in mbar 6 5 3 1 75 kw Manometric height in mbar 6 5 3 1 17 kw 6 8 EMC-M 3/35 MI and 3/39 MI 7 1 13 1 1 16 Flow rate in l/h 6 8 1 13 1 1 16 Flow rate in l/h Manometric height in mbar 6 5 3 1 317 187 3 kw 35 kw 6 8 1 1 1 16 15 15 Flow rate in l/h NANEO_Q8 Condensates discharge The siphon provided must be connected to the waste water discharge system. The connection must be removable and the flow of condensates visible. The connections and pipes must be in corrosion-resistant material. An optional condensates neutralisation system is available (package HC 33 see page 8). 11

1 5 1 C 1 bar 3 1 5 1 C 1 bar 3 1 1 ON OFF AU T ON OFF AU T EXAMPLES OF INSTALLATIONS EXAMPLES OF INSTALLATIONS The examples presented below cannot cover the full range of installation scenarios which may be encountered. Their purpose is to draw the attention to the basic rules to be followed. A certain number of control and safety devices (some of which are already integrated as standard in NANEO boilers) are represented but it is ultimately up to installers, experts, consultant engineers and design departments to take the final decision on the safety and control devices to be used in the boiler room according to its specificities. In all cases, it is necessary to abide by the codes of practice and prevailing regulations. EMC-M MI with 1 direct underfloor heating circuit and DHW production, controlled by 1 wireless modulating thermostat Opentherm + outside temperature sensor 1 13.. c 65 3V 5Hz 7 8 3 9 9 68 NANEO_F11A EMC-M /BS 8 with 1 direct circuit + DHW production circuit, controlled by a programmable room thermostat (wire) 9 3V 5Hz 33 51 8 3 9 7 External clock 8 3V 5Hz 6 7 8 9 9 3 68 NANEO_F1C Legend: see next page 1

5 1 C 1 bar 3 1 1 5 1 C 1 bar 3 1 1 C C C C C C C C ON OFF AU T ON OFF AU T EXAMPLES OF INSTALLATIONS EMC-M MI with 1 underfloor circuit and 1 direct circuit and DWH production, controlled by 1 modulating thermostat «OpenTherm» + outside temperature sensor AD9 1 FM6 BUS 3V 5Hz AD91 AD91 13.. c 13.. c 51 3 6 7 7 65 3 8 3 9 9 EA1 1 8 8 7 11b 9 9 9 68 NANEO_F16B EMC-M MI with 1 underfloor circuit and 1 direct circuit. DWH produced by a solar calorifier with mixing valve kit (package HR 8) 1 FM6 131 11a AD9 3V 5Hz AD91 BUS AD91 19 13.. c 13.. c 51 3 65 7 7 6 3 EA1 1 8 8 7 11b 68 19 8 79 13 87 9 8 85 9 88 3V 5Hz 9 9 9 8 3 9 9 BESL...N 11b 11 89 NANEO_FA Legend 1 Heating outlet Heating return 3 Safety valve 3 bar 8 Manual air vent 9 Isolation valve 1 Outside sensor 7 Non-return valve 8 Domestic cold water inlet 9 Pressure reducer 3 Sealed safety device calibrated to 7 bars (mandatory, in compliance with safety directives) 3 (Optional) DHW loop pump 33 DHW temperature sensor 65 C limiter thermostat with manual reset for underfloor heating 51 Thermostat valve 6 Radiator circuit (gentle heat radiators, for example) 65 Low temperature circuit (underfloor heating, for example) 68 Condensates neutralisation system 13

INFORMATIONS REQUIRED FOR INSTALLATION AIR/FLUE GAS CONNECTION For the use of the air/flue gas connection pipes and the rules on installation, see details of the various configurations in the current product catalogue. Configuration C 13x : Air/flue gas connection by means of concentric pipes to a horizontal terminal (so-called forced flue) Lmax = L1+L L1 Lmax C 13x L L Lmax C 33x Lmax C 3x 1 C 3x C 33x Lmax Lmax Lmax Configuration C 33x : Air/flue gas connection by means of concentric pipes to a vertical terminal (roof outlet) or Configuration C 93x : Air/flue gas connection using concentric pipes in the boiler room and single pipes in the chimney (combustive air with counter current in the chimney) or Air/flue gas connection using concentric pipes in the boiler room and single flex pipes in the chimney (combustive air with counter current in the chimney) L1 Lmax = L1+L 1 C 53 1m max B 3P 5 6 1 3 1 C 3x C 93x 1m max 1m max Lmax C 93x C 33x MCR_F11C Configuration C 53 : Separate air and flue gas connection using a twin pipe adapter and single pipes (combustive air taken from outside) Configuration B 3P : Connection to a chimney (combustive air taken from the boiler room) Configuration C 3X : Connection to a collective shared flue system Table of maximum air/flue gas pipe lengths admissible according to boiler type Lmax of the connecting pipes in m Type of air/flue gas connection NANEO EMC-M /8 MI 3/35 MI 3/39 MI Ø 6/1 mm 7 7 3 3 Concentric pipes connected to a horizontal terminal (PPS) C 13x Ø 8/15 mm 1.5 5.5 11.5 9.5 Concentric pipes connected to a vertical terminal (PPS) C 33x Ø 8/15 mm 19.5 13.5 11.5 Pipes - concentric in the boiler room, - single in the chimney (combustive air with counter current) (PPS) Pipes - concentric in the boiler room, - flex in the chimney (combustive air with counter current) (PPS) Twin pipe adapter and separate single air/flue gas pipes (combustive air taken from outside) (Alu) C 93x C 93x C 53 Ø 8/15 mm Ø 8 mm Ø 8/15 mm Ø 8 mm Ø 6/1 mm to x 8 mm 18 3 19 17 5 15 13 1.5 18 In the chimney (rigid or flex) (combustive air taken from the premises) (PPS) B 3P Ø 8 mm (flex) 39 (1) (1) 1 18 Ø 8 mm (rigid) 33 9 Shared flue system for sealed boiler C 3x To size such a system, contact the supplier of the shared flue system duct (1) : Max. height in the flue pipe (configuration B 3P ) from the support elbow to the outlet mustn t exceed 5 m for flex PPS. In case of higher lengths, holding collars must be added by slices of 5 or 3 m. 1

DESCRIPTION NANEO EMC-M... WALL-HUNG GAS CONDENSING BOILER FOR CONNECTION TO A CHIMNEY OR A FORCED FLUE Brand: De Dietrich Classification: according to the european efficiency directive, NOx classification: 5 Model: - EMC-M for heating only - EMC-M /BS 8 or BS 13 for heating and domestic hot water preparation by associated DHW tank - EMC-M /8-3/35-3/39 MI: for heating and instant domestic hot water production Homologation: B 3 -B 3P -B 33 C 13x -C 33x -C 93x -C 53 -C 3x -C 83x Protection index: IPXD Power supply: 3 V/5 Hz Gas category: all natural gases, propane Useful output in heating mode at 5/3 C: kw Nominal output in DHW mode at 8/6 C: - EMC-M /BS : kw - EMC-M /8 MI: 7.5 kw - EMC-M 3/35 MI: 33.9 kw - EMC-M 3/39 MI: 37.8 kw Specific flow in DHW mode: - EMC-M /8 MI: 1 l/min - EMC-M 3/35 MI: 17 l/min - EMC-M 3/39 MI: 19 l/min - EMC-M/BS : l/min Max. operating temperature: 9 C Max. operating pressure: 3 bar Safety thermostat: 11 C Dimensions: 368 x 589 x 36 mm Weight empty: kg DESCRIPTON Complies with the requirements of European Directives New compact and ultra-responsive exchanger in cast aluminium/ silicium alloy Stainless steel gas burner with complete premixing, modulating from to 1% output, fitted with a silencer on the air intake Removable control panel located under the boiler can be deported to the wall. As delivered, it can be used to control and regulate a direct circuit and 1 DHW circuit (sensor optional). Boiler delivered with a mounting frame with prefitted water, gas valves, disconnector, manometer, flow collector, 1 speed heating pump, 3 bar safety valve, 8 litres expansion tank, heating/dhw reversal valve, plate exchanger with large exchange surface for the production of DHW (for EMC-M MI only), automatic air vent. EMC-M/BS: with enamelled 8 litre DHW calorifier placed to the right or to the left of the boiler, or 13 litres DHW calorifier placed under the boiler. Boiler/tank connecting pipes and DHW sensor have to be ordered separately. EMC-M MI: the plate exchanger produces large quantities of instant hot water. Model is equipped with a flow limiter. Air/flue gas connection Ø 6/1 mm with measuring point Control panel options - Domestic hot water sensor - Programmable room thermostat (wire and wireless) - Modulating room thermostat (wire and wireless) - Outside temperature sensor - Domestic hot water sensor Boiler options - Height adjustment frame, connecting pipe kit for height adjustment frame - Pipe cover, connection pipe kit for replacing an existing boiler - Heating pump class A, solar kit with mixing valve - Flue gas temperature sensor, brush cleaning heat exchanger (only for EMC-M MI) - Service tool - Condensate neutralisation tank - Wall bracket for neutralisation tank - Granule refill for neutralisation tank - Twin pipe adapter x Ø 8 mm, flue gas adapter low profile - Horizontal terminal PPS Ø 6/1 mm - Flue gas adapter Ø 8/15 mm - Vertical flue terminal Ø 8/15 mm (black and red) - Calorifier BMR 8 and SR 13, connection kit boiler/calorifier. 15

DE DIETRICH THERMIQUE Simplifi ed Share Company with registered capital of 87 61 57, rue de la Gare - F-6758 MERTZWILLER Tel. +33 ()3 88 8 7 - Fax +33 ()3 88 8 7 99 www.dedietrich-heating.com 3/13 39977A 37.555.559 Strasbourg Companies Register Document not contractually binding - Printed in France - OTT Imprimeurs 6731 Wasselonne - 13169