ACK QUATTRO 06 16T INVERTER Fan coil Outdoor unit Booster R Floor radiant system Integrated indoor unit with DW storage 94
ACK QUATTRO 06 16T INVERTER Models ACK QUATTRO 06 AR 1 ACK QUATTRO 08 AR 1 ACK QUATTRO 10 AR 1 ACK QUATTRO 12 AR 1 ACK QUATTRO 14 AR 1 ACK QUATTRO 14 Three phase AR 3 ACK QUATTRO 16 Three phase AR 3 ACK QUATTRO 06 ARS 1 ACK QUATTRO 08 ARS 1 ACK QUATTRO 10 ARS 1 ACK QUATTRO 12 ARS 1 ACK QUATTRO 14 ARS 1 ACK QUATTRO 14 Three phase ARS 3 ACK QUATTRO 16 Three phase ARS 3 ACK QUATTRO 06 AR 1 ACK QUATTRO 08 AR 1 ACK QUATTRO 10 AR 1 ACK QUATTRO 12 AR 1 ACK QUATTRO 14 AR 1 ACK QUATTRO 14 Three phase AR 3 ACK QUATTRO 16 Three phase AR 3 ACK QUATTRO 06 ARS 1 ACK QUATTRO 08 ARS 1 ACK QUATTRO 10 ARS 1 ACK QUATTRO 12 ARS 1 ACK QUATTRO 14 ARS 1 ACK QUATTRO 14 Three phase ARS 3 ACK QUATTRO 16 Three phase ARS 3 Accessories ACK QUATTRO 06 16T INVERTER Thermal ower Cooling Capacity Code 62391900 62391901 62391902 62391903 62391904 62391905 62390990 62390991 62390992 62390993 62390994 62390995 62390996 62390997 62390998 62390999 62380000 62380001 62380002 62380003 62380004 62380005 62380006 62380007 62380008 62380009 62380010 62380011 First start 35639901 Remote control multifunctional touch screen 37900812 Internal diverter valve kit with DW probe Electrical resistance mod. monofase 2 mod. trifase 2 mod. monofase 3 mod. trifase 3 mod. monofase 4,5 mod. trifase 4,5 included 62391003 62391004 62391005 62391006 62391007 62391008 8-liter expansion tank on the system side 62391009 95
ACK QUATTRO 06 16T INVERTER Accessories ACK QUATTRO 06 16T INVERTER Code Rubber anti-vibration kit 62391014 Antifreeze kit mod. 06 12 mod. 14 16T 62391013 62391012 (Optional kit, factory installed, model G2) DW recirculation management logic - Solar integration management logic Relay circulator management logic DW technical boiler kit: allows the unit to be connected to an additional one energy source (boiler or similar) to be managed in integration and / or replacement of the ACK QUATTRO heat pump 62391010 62391011 Indoor unit AR version - ARS 1 250 l technical water puffer for DW (domestic hot water) 50 mm polyurethane coating 2 igh efficiency pump of heat pump and high efficiency in-line preparer with the ER directive up to EEI values = <0.21 3 eat pump exchangers and rapid ACS manufacturer in AISI 304 stainless steel 4 Integrated Y-filter 5 DW technical side loading / unloading cock 6 Integrated automatic air vent valve for the DW technical side 7 Double pressure gauge at 6 bar to check flow rates / load losses 8 8-liter expansion vessel on the DW technical side 9 3 bar safety overpressure valve to be connected to a collection system 10 3-way valve switching system / DW technical side 11 Safety flow switch for heat pump exchanger protection 12 Flow meter for rapid production management of the DW 13 Single-phase or three-phase power supply 14 ogic management of electrical resistance on the plant side in integration and / or replacement 15 ogic management boiler or similar source both for the plant side and for the technical DW in integration and / or replacement of the heat pump (digital contact) 16 Climatic integrated system 17 System remote probe management logic 18 ogic management of double set-point on the integrated system side 19 ogic management of integrated intelligent energy resources Indoor unit AR - ARS version (double puffer version) 1 Technical water puffer for DW (hot water) 190 l and technical plant puffer 40 l, 50 mm polyurethane coating 2 igh efficiency quick heat pump and preparer circulator in line with the ER directive up to EEI values = <0.21 3 eat pump exchangers and rapid DW manufacturer in AISI 304 stainless steel 4 Integrated Y-filter 5 oad / unload taps both on the DW technical side and on the plant side 6 Automatic air vent valves integrated both on the plant side and on the DW technical side 7 Double pressure gauge at 6 bar to check flow rates / load losses 8 Double 8 liter expansion tank, one side plant the other technical side DW 9 3 bar safety overpressure valve to be connected to a collection system 10 3-way valve switching system / DW technical side 11 Safety flow switch for heat pump exchanger protection 12 Flow meter for rapid production management of the DW 13 Single-phase or three-phase power supply 14 ogic management of electrical resistance on the plant side in integration and / or replacement. 15 ogic management boiler or similar source both for the plant side and for the technical DW in integration and / or replacement of the heat pump (digital contact) 16 Climatic integrated system 17 System remote probe management logic 18 ogic management of double set-point on the integrated system side 19 ogic management of integrated intelligent energy resources 96
ACK QUATTRO 06 16T INVERTER ARTICUARY CURATED DESIGN The new hanging and closet units were designed directly by great designers of the made in Italy. COMACT DIMENSIONS This is a floor-mounted heat pump system which includes the domestic hot water tank and a puffer with technical water (in the AR version) e all the components of the system. The installation is thus facilitated to the end user. It is offered an efficiency, design and reduced size, like that of a normal household appliance. TECNICA WATER ACCUMUATOR The tank is equipped with a thick insulation in 50 mm polyurethane. The thermal dispersion of the tank is 79 W (according to EN 12897: 2006 ΔT = 45 C). The heat pump system can lead to temperatures of comfort of the water in the tank avoiding the use of a optional auxiliary electric heater, ensuring immediate availability of a volume of hot water enough for six showers (AR / ARS version). UG AND AY INSTAATION All hydraulic components of the unit (circulator heat pump and DW device, expansion vessels, electric resistances, diverter valve and components various and electric) are easily accessible by opening the front panel, water and coolant connections they are in the high back of the unit (in the case of the closet model) this ensures ease of maintenance and installation. Indoor unit dimensions AR - ARS - AR - ARS Version AR Version ARS AR AR Technical plant puffer 40 l 40 l 40 l 189 202 uffer ACS uffer DW 190 l 250 l 190 l 250 l 190 l 250 l 190 192 203 205 Dimensions U.M. mm 595 595 595 ARS 204 ARS 217 mm 705 705 705 205 218 mm 1830 1830 1830 207 220 97
ACK QUATTRO 06 16T INVERTER Outdoor unit dimensions ACK QUATTRO - 10 INVERTER ACK QUATTRO Values in mm 06 925 380 785 08 925 380 785 10 1047 465 913 Technical data table for heat pumps ACK QUATTRO - 10 INVERTER DESCRITION Cooling capacity (1) Absorbed ower (1) E.E.R. (1) Cooling capacity (2) Absorbed ower (2) E.E.R. (2) SEER (5) Thermal ower (3) Absorbed ower (3) C.O.. (3) Thermal ower (4) Absorbed ower (4) C.O.. (4) SCO (6) Energy efficiency** Compressor Type ower supply Fans External temperature Max operating current Sound evel (7) ump ower (3) Water flow (3) Gas attacks iquid attacks Min. Water Volume Weight in operation U.M. WW n x C A db(a) m 3 /h l 06 7,56* (3,65 6,87) 1,69 4,06 5,58* (2,32 5,07) 1,74 2,91 3,59 7,37* (2,84 6,77) 1,47 4,61 6,90 (2,28 6,27) 1,83 3,43 3,92 13,6 62,0 0,075 1,16 31 62,0 08 9,12* (4,65 8,52) 2,18 3,91 6,73* (2,95 6,12) 2,11 2,90 3,61 8,90* (3,56 8,09) 1,85 4,37 8,80 (2,88 8,00) 2,40 3,33 3,91 A++ / A+ Twin Rotary DC Inverter 230V/1/50z 1 x 0,15-20 / +46 20,4 62,5 0,075 1,39 3/8 5/8 37 62,0 10 11,35* (5,40 10,00) 2,26 4,43 8,83* (3,27 7,56) 2,43 3,11 4,63 10,80* (4,69 10,00) 2,26 4,43 10,30 (3,90 9,51) (1) Cooling: outdoor air temperature 35 C; water temperature entry/issue 23/18 C. (2) Cooling: outdoor air temperature 35 C; water temperature entry/issue 12/7 C. (3) eating: outdoor air temperature 7 C b.d. 6 C b.h.; temp.water entry/issue 30/35 C. (4) eating: outdoor air temperature 7 C b.d. 6 C b.h.; temp.water entry/issue 40/45 C. (5) Cooling: water temperature entry/issue 7/12 C. (6) eating: average climate conditions; Tbiv = -7 C; temp.water entry/issue 30/35 C. (7) Sound power, condition heating mode (3); value determined on the basis of measurements carried out in accordance with the UNI EN ISO 9614-2 standard, in compliance with the requirements of the Eurovent certification. (8) Value for any type of connected indoor unit. * Maximum power with z Max function not enabled by default. ** Water 35 C / 55 C 2,74 3,47 4,24 21,6 63,0 0,009 1,72 46 83,5 98
ACK QUATTRO 06 16T INVERTER Outdoor unit dimensions ACK QUATTRO 12-14 - 14T - 16T INVERTER ACK QUATTRO Values in mm 12 1047 465 913 14 1060 455 1405 14T 16T 1060 1060 455 455 1405 1405 Technical data table for heat pumps ACK QUATTRO 12-14 - 14T - 16T INVERTER DESCRITION Cooling capacity (1) Absorbed ower (1) E.E.R. (1) Cooling capacity (2) Absorbed ower (2) E.E.R. (2) SEER (5) Thermal ower (3) Absorbed ower (3) C.O.. (3) Thermal ower (4) Absorbed ower (4) C.O.. (4) SCO (6) Energy efficiency** Compressor Type ower supply Fans External temperature Max operating current Sound evel (7) ump ower (3) Water flow (3) Gas attacks iquid attacks Min. Water Volume Weight in operation U.M. WW n x C A db(a) m3/h l 12 13,10* (5,40 11,90) 2,65 4,49 9,60* (3,27 8,49) 2,74 3,10 4,73 12,70* (4,69 12,10) 2,89 4,19 3,32 3,41 4,31 A++ / A+ 14 14T 15,2* (6,70 13,80) 2,93 4,72 12,05* (5,30 11,46) 3,70 3,10 4,51 15,10* (5,50 13,76) 3,20 4,30 4,04 3,35 4,01 A++ / A+ Twin Rotary DC Inverter 230V/1/50z 1 X 0,15 16T 16,30* (8,70 15,69) 3,20 4,90 16,00* (6,30 14,64) 4,52 3,24 4,77 15,90* (7,10 15,21) 3,45 4,41 15,80* (6,50 15,17) 4,38 3,46 4,07 A++ / A++ 400V/3+N/50z 2 X 0,15-20 / +46 26,1 63,5 0,09 2,08 31,8 10,0 65,5 10,6 66,0 0,14 2,37 3/8 5/8 69 112,2 51 83,5 (1) (2) (3) (4) (5) (6) (7) 2,62 88 123,0 Cooling: outdoor air temperature 35 C; water temperature entry/issue 23/18 C. Cooling: outdoor air temperature 35 C; water temperature entry/issue 12/7 C. eating: outdoor air temperature 7 C b.d. 6 C b.h.; temp.water entry/issue 30/35 C. eating: outdoor air temperature 7 C b.d. 6 C b.h.; temp.water entry/issue 40/45 C. Cooling: water temperature entry/issue 7/12 C. eating: average climate conditions; Tbiv = -7 C; temp.water entry/issue 30/35 C. Sound power, condition heating mode (3); value determined on the basis of measurements carried out in accordance with the UNI EN ISO 9614-2 standard, in compliance with the requirements of the Eurovent certification. (8) Value for any type of connected indoor unit. * Maximum power with z Max function not enabled by default. ** Water 35 C / 55 C 99