Power X High Power Condensing Wall-Hung Boilers

Similar documents
Power X High Power Condensing Wall-Hung Boilers

Exclusive Green E Condensing Wall-Hung Boilers

Ciao Green Condensing Wall-Hung Boilers

MySMART Condensing Wall-Hung Boilers

Mynute Green Condensing Wall-Hung Boilers

Tower Green HE Hybrid

Mynute Green k. Condensing Wall-Hung Boilers. Residential Heating

International Markets. Product Catalogue. complementary items

1 VICTRIX ZEUS Superior kw I features

Fonte Lx NEW. Instantaneus Gas Water Heaters, conventional flue, low NOx. Residential Heating. compliant. Fonte Lx 14. Fonte Lx 11

ENERGY TOP. Condensing boiler solutions

5 YEAR ADVANCE PLUS WARRANTY. High efficiency condensing combi and system boilers

Technology marries design. The boiler finally becomes a piece of design, emerging as a protagonist in a new domestic environment.

VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power

HIGH POWER. VICTRIX PRO 2 ErP. High power, wall-hung condensation boiler

WALL HUNG GAS BOILER FOR C.H. AND PREDISPOSTION FOR INSTANTANEOUS D.H.W. PRODUCTION (with optional kit) MODELS 34,8 kw (depotenziata) 50 C

Technology marries design. The boiler finally becomes a piece of design, emerging as a protagonist in a new domestic environment.

VICTRIX Superior kw Export VICTRIX Superior kw X Export

VICTRIX 50 1 SPECIFICATIONS. Wall mounted condensing boilers

TRADITIONAL NIKE/EOLO STAR. Wall-hung combi boilers

SPECIFICATIONS - NIKE

5 YEAR GUARANTEE. Inovia. High efficiency condensing combi and system boilers

Divacondens D Plus Atmospheric condensation wall-mounted boilers, with instant domestic hot water production

Superior. A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler. Outputs 120, 160, 200, 240, 280 kw

C Tahiti. condensing

AVIO kw Export 1 FEATURES. Wall-mounted with storage tank

Seradens Super Seradens Super Plus

24/31-28/35-33/40 kw Premix System Condensing - ErP Combi Gas Boilers. Enerwa / EnerwaPlus.

Condensing, pre-mixed, wall-hung gas boilers with water tank

Pure technology. Clean design and practical panel board with wide Power save display !DEA AR 23 !DEA RS !DEA AC 23 !DEA CS

CAST IRON ATMOSPHERIC BOILERS

CITY PLUS. Wall-hung condensing boilers. ErP 24 HE 30 HE. Ready

BWA. CONDENSING WALL HUNG BOILER FROM 50 kw TO 140 kw

The iqe Boiler Range. Combination and System T Boilers.

MINORCA KC - KR - KRB 24

WALL-HUNG GAS CONDENSING BOILERS MCR-P 24/28 BIC. HOMOLOGATION B 23P - C 13x - C 33x - C 93x -C 53 - C 43x - C 83x *

ALKON CARGO. A precise and fast delivery rate. A very high specific flow rate (20 litres per minute with Dt 25)

WALL-HUNG HIGH EFFICIENCY GAS BOILERS. Elegant, efficient and intelligent

Quinta Pro Range. The New Remeha. Condensing Boilers REMEHA QUINTA PRO RANGE. High efficiency wall hung condensing boiler with ultra low NOx emission

ALKON 90 ALKON 90 MODEL 24,0 93,6 21,1 87, nominal heat output. conventional. max/min heat input. efficiency class (Directive 92/42)

ACCUMULATION OF EUROPEAN CLASS

24-28 kw Conventional Combi Gas Boiler. Lawa / LawaPlus

RMG MK. II RMG Mk.II RS Mk.II RMG Mk.II RS Mk.II

WALL-HUNG HIGH EFFICIENCY GAS COMBINATION BOILERS. Efficient, economical and easy

Bluehelix Tech RRT Wall-hung condensing boiler with Ferroli Thermobalance heat cell

Floor standing boilers. RMG Mk.II RS Mk.II

AGUAdens TM 100% residential condensing D.H.W. wall-mounted water heaters ( litres) AISI 316 D.H.W. WORKING PRESSURE TITANIUM CONDENSING

General catalogue COMMERCIAL AND TECHNICAL INFORMATION. Commercial Range. March 2015 Edition

Installation and Operation Manual IDRA PLUS DS. Solar Solar storage cylinder. Installation and Operation Manual

ZENA PLUS EASYLIFE WALL-HUNG GAS BOILERS

Compact HRE Boiler Range. The smart choice for heating and hot water

CITY OPEN - CITY BOX from 25 to 35 kw

white blue cobalt bordeaux light oak (rovere)

INDEPENDENT COMBINATION & SYSTEM BOILERS.

HEAT ONLY & COMBI BOILER

Installation Manual STOR C. Solar combination storage cylinder. Installation Manual

FORMENTERA KC - KRB - KR

Rapid. Suspended Warm Air Heater. Caring for the environment!

MODULAR GAS CONDENSING UNIT EQUIPPED WITH PRIMARY RING and premix modulating Low NO x. from 100 to 900 kw and in battery up to 8 units

The competent brand for energy saving systems NEW. Gas-combi boiler CGG-1K-24/28

Ideasandformsinevolution

Ethos Range High Efficiency Domestic Boilers. Combination Boilers Condensing Combination Boilers Condensing System Boilers

Flue gas condensation...

WALL-HUNG SYSTEM & UNVENTED CYLINDERS

Our Boiler Family Our Boiler Family

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

NIKE Star 24 3 E. Instantaneous wall-hung with open chamber boilers. NIKE Star 24 3 E

Capri B Cast iron combination oil-fired boiler with water tank

C Nias Dual. Wall-hung boilers, forced draught, sealed chamber with storage tank. For indoor installation. Life-enhancing heat

24/31-28/35-33/40 kw Premix System Condensing Combi Gas Boilers. Priwa / PriwaPlus.

VERVE I 50. Installation & Servicing Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER

WOLF GAS CONDENSING BOILERS COMFORTLINE

Residential Heating Boilers

FEATURES AND BENEFITS. Up to 109.8% part load efficiency

Wall hung combination

solar storage cylinder

4FLOOR-STANDING GAS CONDENSING BOILERS

Room sealed circuit appliance sold without the terminal or the combustion air supply and exhausted gas ducts. TYPE C 63 TYPE B TYPE B 23

COMPACT HRE ECO RF COMPACT HRE & ECO RF SMART CHOICE FOR HEATING AND HOT WATER

MAIOR EOLO 4 E. Instantaneous wall-hung boilers, sealed-room with "Aqua Celeris" system MAIOR EOLO 4 E

wall-mounted boilers, water heaters and pool heaters floor standing boilers, water heaters and pool heaters

Clyde Alkon 90. Floor standing condensing boilers. Natural Gas. 90 kw. LP Gas. 90 kw

2.1 BOILER ROOM BOILER ROOM DIMENSIONS 2.3 CONNECTING UP SYSTEM 2.4 CONNECTING UP FLUE 2.5 ELECTRICAL CONNECTION

WALL-HUNG HIGH EFFICIENCY GAS BOILERS

AquaKond Split. Caring for the environment! New Condensation Boilers. Efficiency up to 109% 4 Stars. AquaKond 70 kw Standard I.S.P.E.S.L.

October Solar Thermal

wall-mounted boilers, water heaters and pool heaters from 15 kw to 140 kw

WELCOME TO REMEHA, THE EXPERT CHOICE INTRODUCING THE REMEHA GAS 110 ECO RANGE FEATURES AND BENEFITS

NANEO EMC-M WALL-HUNG GAS CONDENSING BOILERS

RIELLO 40 GS/M SERIES

PCH/new Series. High performance, total flexibility

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ

VERY LOW TEMPERATURE CONDENSING UNIT Low NOx Class 5 MODELS SEASONAL EFFICIENCY A A A A A A A

Installation and Operation Manual IDRA N DS. Solar solar storage cylinder. Installation and Operation Manual

hxi High Efficiency Heating Only 24hxi hxi High Efficiency Heating Only 30hxi hxi High Efficiency Heating Only 38hxi

D O M E S T I C Solar Thermal

Bluehelix Tech Wall-hung premix condensing boilers, only heating or instant combi operation

C Elba Dual. Cast-iron, floor-standing boiler. High quality Italian product. Life-enhancing heat

RK 50. High Efficiency Condensing Wall Hung Boiler Heating Only. Suitable for Cascade Systems SEDBUK BAND A CE 0694 TA01E011.A0405 TA05E011.

IMAX XTRA EL. 715kW FLOOR STANDING CONDENSING FEATURES AND BENEFITS

Transcription:

Power X High Power Condensing Wall-Hung Boilers NEW Residential Heating/Light Commercial compliant

POWER X / High Power Condensing Condensing Wall-Hung Wall-Hung Boilers Boilers Power X: the new high power range by Beretta Power X is a high power condensing wall-hung boiler, designed for light commercial applications, like villas and multi-dwelling units. It comes in models that, thanks to a complete range of accessories, can be configurated in different ways, according to your installation and comfort needs: - Power X 0 (only heating model); - Power X R.S.I., 0 DEP R.S.I., 0 R.S.I. (only heating models with built-in -way valve).

POWER X / High Power Condensing Wall-Hung Boilers TECHNOLOGY AND CONTROL Simple and user-friendly control panel Power X is featured by a simple and user-friendly digital display that provides the end-user immediately with all information about the boiler status. The touch buttons allow to easily select all the functions necessary to the use and setting of the boiler. KEY: Digital display for information about boiler status Digital display for heating/dhw temperature setting ON/OFF and reset selector Touch button for central heating temperature increase Touch button for central heating temperature decrease Summer/winter selector Touch button for DHW temperature increase Touch button for DHW temperature decrease Saving energy, saving money The new energy labelling, that according to the ErP directive was implemented in September 0 for appliances and systems producing heating and domestic hot water, means that all boilers and heating systems are labelled in the same way as white goods, like washing machines and refrigerators. The energy labelling enables the end-users to make realistic comparisons among different products. By choosing high efficiency products, the end-users can lower their energy bills, helping to safeguard the environment. Seasonal space heating energy efficiency Power X R.S.I. A Sound power level Energy efficiency class Rated heat output Note: The values in this label refer to POWER X R.S.I. Specifications for each model are detailed at page 9.

POWER X / High Power Condensing Wall-Hung Boilers TECHNOLOGY AND CONTROL High condensing technology The Power X condensing heat exchanger has a high exchange surface and an excellent corrosion resistance. It is made of a continuous corrugated bi-metallic tube (copper alloy on the water side and stainless steel on the flue side), coiled up inside a cylidric structure in stainless steel. This structure is closed on the upper side by a header in die-cast aluminium and on the lower side by a composite plastic header. The counter flow heat transfer is particularly advantageous as the flue temperature is lowered ( C more than the return water). The total pre-mix burner ensures a constant calibrated gas and air mix under any running conditions, translating into highest efficiency. KEY 9 Fan Gas valve Air inlet Flue outlet Condensate drain Ignition and flame control electrode Air/Gas conveyor Burner 9 Heat exchanger 0 Return pipe 0 Heat exchanger made of a coiled corrugated bimetallic pipe. Pre-mix burner: Low NOx Class (Directive EN ) Thermoregulation as standard with outdoor probe as option Gas Directive EEC 90/9 Low voltage Directive EEC 9/ Electromagnetic compatibility Directive EEC / Section of bimetallic corrugated pipe

POWER X / High Power Condensing Condensing Wall-Hung Wall-Hung Boilers Boilers TECHNOLOGY AND ADVANTAGES New bimetallic (stainless steel - copper) condensing heat exchanger Modulation ratio up to : Condensate collector syphon Low Energy modulating synchronous pump (ErP compliant - EEI 0,0), m head, with anti-blockage cycles system Built-in -ways valve as standard (on the models R.S.I, 0 DEP R.S.I., 0 R.S.I.) Electronic board with self-diagnostic function and frost protection Total pre-mix burner with low emissions: Class (UNI EN ) Possibility to directly connect a DHW tank via the built-in -ways valve (on R.S.I. models) or via an external -ways valve (on 0 model), for the production of DHW Climatic thermoregulation as standard with outdoor probe (as option) Flue gas analysis Built-in lt. expansion vessel (on R.S.I. model) and lt. expansion vessels available as option (for the 0 DEP R.S.I., 0 R.S.I. and 0 models) Management of three circuits: high temperature, low temperature and DHW tank T flue/water return: max C

POWER X / High Power Condensing Wall-Hung Boilers TECHNOLOGY AND EFFICIENCY Low Energy pump and differential pressure switch The Power X boiler range is equipped with the new Low Energy modulating pump already connected hydraulically and electrically, providing a high energy saving and a significant reduction in electrical consumption. The new pump, thanks to the innovative electronic board already inside to the boiler, can work in two modality: as modulating and in a fixed way. The pump in a fixed mode, can work with three speeds: - low-speed - normal speed - maximum speed The factory setting is for modulating mode: in this case, on the system request, the pump starts at maximum speed for minute and modulates, up to the achievement of the ΔT required (ΔT is selectable). The boiler is equipped also with an anti-blocking system, which activates an operating cycle after every hours of disuse, regardless of the mode selector s position. The flow rate indicated in the graph refer to the range of possible speeds. Power X also features a differential pressure switch, which detects a minimum value of flow rate and system pressure. Other hydraulic accessories and safety devices are available for Power X range (see the following pages). Residual head residual head m.w.c. 0 0,0 0, 0, 0, 0,,0,,,,,0, flow rate m /h BeSMART WiFi compatible Power X is compatible with the BeSMART WiFi (as ON/OFF thermostat), the new solution by Beretta to manage your home heating from wherever you are in the world, via the BeSMART App. From any smartphone or tablet you will be able to programme your comfort in an easy and intuitive way, adapting your heating times to your lifestyle or dayly program. BeSMART WiFi is very easy and quick to install and allows to manage up to heating zones. All main heating program information are displayed on the thermostat or available via App. For further information visit our website berettaboilers.com or besmart-home.com.

TECHNICAL DRAWINGS POWER X R.S.I. POWER X 0 - POWER X 0 R.S.I. - POWER X 0 DEP R.S.I. 0 9 0 9 a b 9 0 9 0 KEY: Automatic air vent valve Deaerator Safety thermostat Flow sensor Condensing heat exchanger Differential pressure switch Flue temperature probe Pump 9 Return sensor 0 Safety valve (, bar) Gas valve Hydrometer Built-in -ways valve (*) Syphon condensate drain a lt. built-in primary expansion vessel (only on the R.S.I. model) b / lt. expansion vessel as option (on the 0 DEP R.S.I., 0 R.S.I. and 0 models) Venturi Gas valve Fan 9 Air inlet 0 Flue Ignition and detection electrode Note: (*) Built-in on all R.S.I. models. For Power X 0 the -ways valve is available as option (cod. 00) to be placed outside the boiler.

TECHNICAL DRAWINGS POWER X 0 / POWER X 0 R.S.I. / POWER X 0 DEP R.S.I. / POWER X R.S.I. 0 0 0 9 Ø 0 R G M SC 0 0 0 0 Mb HYDRAULIC CIRCUIT F A KEY: T T/F R 0a /0b L H T P Mb M 9 G Condensing heat exchanger Modulating pump Fan Automatic air vent valve Differential/minimum pressure switch Flue temperature probe Flow sensor (central heating) Return sensor (central heating) 9 Built-in -ways valve (except for Power X 0) 0a lt. expansion vessel as standard on R.S.I. model 0b and lt. expansion vessels as option for 0, 0 DEP R.S.I. and 0 R.S.I. models Safety valve (, bar) Boiler drain Deaerator Safety thermostat A Air G Gas (M / G) F Flue R Central Heating return* (M G) M Central Heating flow (M G) Mb DHW tank flow (only on R.S.I. models) SC Condensate drain Note: (*) For the R.S.I. versions it is available the connection kit for DHW tank return (code 0).

TECHNICAL DATA FEATURES and MODELS POWER X R.S.I. POWER X 0 DEP R.S.I. POWER X 0 R.S.I POWER X 0 Product order code 0 0 0 0 Boiler function heating only with built-in ways valve (*) heating only ENERGY LABELLING SPECIFICATIONS (according to ERP regulation) Seasonal space heating energy efficiency class A A A A Seasonal space heating energy efficiency % 9, 9, 9, 9, Sound power level inside db,,, SPECIFICATIONS Heat input ref. Hs (HHV) min-max kw, -,0,0 -,,0-0,0,0-0,0 Heat input ref. Hi (NHV) min-max kw, -,, -,, -,0, -,0 Useful heat output ref. Hi (NHV) (0-0 C) kw 0,90,,0,0 Useful heat output ref. Hi (NHV) (0-0 C) kw,00,0,0,0 Quantity of condensate (0-0 C) NG l/h,,,, Useful efficiency ref. Hi (NHV) (0-0 C) % 9,00 9,0 9,0 9,0 Useful efficiency ref. Hi (NHV) (0-0 C) % 0, 0,0 0,0 0,0 Useful efficiency at ref. HI (NHV) 0% (0-0 C) % 9,99 9,0 9,0 9,0 Useful efficiency at ref. HI (NHV) 0% (0-0 C) % 09,0 0,0 0,0 0,0 Losses via the chimney with the burner operating (0-0 C)/(0-0 C) %,/0,,/0,9,/0,9,/0,9 Losses via the chimney with the burner off % 0, 0, 0, 0, Losses via the casing with the burner operating % 0, 0, 0, 0, Flue gas temperature C Return temperature + max C NOx Class CENTRAL HEATING Maximum operating pressure bar,,,, Range of boiler water temperature settings (min/max) C 0/0 0/0 0/0 0/0 Hydraulic residual head at 000l/h bar 0, 0, 0, 0, ELECTRICAL SPECIFICATIONS Power supply V/Hz 0/0 0/0 0/0 0/0 Index of electrical protection IP XD XD XD XD Fan power consumption W 0 00 00 Pump power consumption W 0 0 0 0 HYDRAULIC AND GAS CONNECTIONS CH flow Ø Gas inlet Ø / / / / CH return Ø TWIN FLUE PIPES AND AIR INTAKE Ø0 Max length m + + + + Loss due to the insertion of a bend 90 / m / / / / DIMENSIONS AND WEIGHT Boiler dimensions (H x L x P) mm 9 x 0 x 9 x 0 x 9 x 0 x 9 x 0 x Dry weight kg 0 Available gas versions NG/LPG (**) NG/LPG (**) NG/LPG (**) NG/LPG (**) (*) The -ways valve allows the DHW production via connection with a DHW tank. (**) LPG version available through LPG transformation kit (supplied as standard) KEY: R heating only model S room-sealed I electronic ignition + ionisation flame control 9

POWER X / High Power Condensing Wall-Hung Boilers ACCESSORIES Accessories and complementary items Power X can be installed in different configurations, according to your installation needs. Beretta offers CODE CODE 09 lt expansion vessel kit Taps for system 0 External probe kit Hydraulic manifold for safety kit 009 Well probe for DHW tank and for Low Temp. zone 09 Limit thermostat for low temperature applications 9 0 Motorized mixing valve kit HYDRAULIC/ELECTRICAL COMPONENTS and SAFETY DEVICES * 0 00 00 a complete range of accessories, designed to be perfectly combined with Power X range. 00 Safety kit (*) 009 Gas safety cut-off valve 00kW SUPPORTS FOR INSTALLATION 00 Hydraulic header separator for single application 00 -way valve kit for DHW tank for single application 000 9 0 Connection kit for DHW tank return (for RSI versions) 000 0 090 lt expansion vessel kit Power X rig (front mounting) Rear mounting kit for free-standing application Rear spacer frame kit for wall-hung application 00 * (in case of concentric flue systems) 9 0 * 9 In case of use of the concentric flue ranges Ø0/00 or Ø0/, with flue exit from the back side wall of the boiler, via a 90 bend, it is necessary to purchase the rear spacer frame kit, code 00 (, mm depth). (*) Note: According to I.N.A.I.L. Italian Safety Certification Institute (mandatory only on the Italian market), the kit is composed by: INAIL type-approved safety thermostat with manual reset [00(0- C)]; INAIL type-approved thermometer (0-0 C); thermometer wellduct; INAIL type-approved safety valve (, bar); INAIL type-approved safety pressure switch with manual reset; INAIL type-approved manometer-holder -ways tap; damper coil; INAIL type-approved manometer (0- bar); brass fitting connection.

ACCESSORIES - FLUES Flue adapters CODE CODE FLUES / AIR INTAKE 00 Air-intake kit B 9 000 Flue adapter kit from Ø0-0 to Ø0/00 0 0009 Flue adapter kit from Ø0-0 to Ø0/ 9 0 Ø0 twin flue system in plastic (PP) CODE CODE 00 bend, Ø0 00 90 bend, Ø0 009 00 mm extension, Ø0 00 000 mm extension, Ø0 00 000 mm extension, Ø0 00 Horizontal terminal extension L=9 mm, Ø0 00 Air inlet horizontal terminal L=0 mm, Ø0 099 Spacers for pipe, Ø0 ( pcs.) Ø0/00 concentric flue system* in plastic (PP/PPu) CODE CODE 009 concentric bend, Ø0-00 000 90 concentric bend, Ø0-00 00 00 mm concentric extension, Ø0-00 00 000 mm concentric extension, Ø0-00 009 000 mm concentric extension, Ø0-00 00 Vertical extension, Ø0-00 - external straight pipe Ø 00 Horizontal terminal extension, Ø0-00 009 Spacers for pipe, Ø00 ( pcs.) Ø0/ concentric flue system* in plastic/aluminium (PP/Al) CODE CODE 099 concentric bend, Ø0-09 000 mm concentric extension, Ø0-009 90 concentric bend, Ø0-09 Concentric extension with inspection, Ø0-09 90 concentric bend with inspection, Ø0-09 Vertical extension, Ø0- - external straight pipe Ø 09 00 mm concentric extension, Ø0-09 Horizontal extension, Ø0-09 000 mm concentric extension, Ø0-000 Spacers for pipe, Ø0- ( pcs.) * In case of use of the concentric flue ranges Ø0/00 or Ø0/, with flue exit from the back side wall of the boiler, via a 90 bend, it is necessary to purchase the rear spacer frame kit, code 00 (, mm depth). Note: Due to exposition to sunlight, the colour of the material (PP) may be altered.

POWER X / High Power Condensing Wall-Hung Boilers DHW TANK Idra BV Idra BV is the ideal DHW tank range to be matched with Power X. It comes in different sizes that can cover all your installation and comfort needs. The two installation schemes in the following page illustrate how Power X can manage a mixed system: High Temperature + Low Temperature and a DHW tank. CODE DIMENSIONS HxØ (mm) CYLINDER CAPACITY (litres) HEAT LOSS (W) ENERGY CLASS A (mm) B (mm) C (mm) D (mm) E (mm) 009 IDRA BV 00 0x0 0 9 B 0 0 009 IDRA BV 00 0x0 0 9 B 0 0 9 0 0099 IDRA BV 0 0x C 0 0 0 00 0 00900 IDRA BV 0 90x 9-0 0 0 00 0090 IDRA BV 00 x000, - 0 0090 IDRA BV 000 x000 90, - 90 00 UAC UAC ES ES H RC E RC KEY: D US US UAC C EAF EAF (SB) ES RC B A US EAF Ø ACCESSORIES CODE CODE 000 / electronic anode kit * 09 lt expansion vessel 09 Thermostatic mixing valve ¾ 009 lt expansion vessel 0009 Thermostatic mixing valve with ¾ adapter 09 lt expansion vessel Note: (*) For the coupling with the electronic anode kit a reduction to / is needed (not included in the kit) DHW outlet Flow DHW recirculation Return DCW inlet

SYSTEM Management of a mixed system: High Temperature + Low Temperature and a DHW tank POWER X 0 0 9 DHW ACS DCW AFS POWER X 0 DEP R.S.I. These schemes have only an indication purpose 9 9 ACS DHW DCW AFS KEY: Power X 0 (0) Power X 0 DEP R.S.I. (0) Hydraulic manifold for safety kit (00) Safety kit (00) Gas safety cut-off valve 00kW (009) Hydraulic header separator (00) -way valve kit for DHW tank (00) 9 Connection kit for DHW tank return (0) 0 lt. expansion vessel (optional kit 090) lt. expansion vessel (optional kit 09) External probe kit (0) Well probe (009) Air-intake kit B (00) Thermostatic mixing valve (09 or 0009) DHW tank IDRA BV Pump ( a ) 9 Motorized mixing valve (0)* Note: ( a ) Not available in the Beretta International Product Catalogue; * Mixing valve with a Vac stepper motor and wires, to be connected on the boiler control board to the terminals dedicated to the Low Temp. zone.

WALL-HUNG APPLICATIONS POWER X 0 DEP R.S.I. / POWER X 0 R.S.I. CONFIGURATION FOR CENTRAL HEATING AND DHW TANK 09 9, 00 00, BOILERS CODE Q.TY 0 Power X 0 DEP R.S.I. (A) HYDRAULIC COMPONENTS and SAFETY DEVICES 00 Taps for system 00 Hydraulic header separator for single applic. CODE Q.TY 9 0 Connection kit for DHW tank return FLUES / AIR INTAKE 00 Air-intake kit B (B) ACCESSORIES FOR DHW TANK (C) - 009 Well probe for DHW tank (A) The configuration illustrated in this page can be applicated also with POWER X 0 R.S.I. (code 0). Inside the Power X boilers range (except for Power X R.S.I.), it is possible to insert, in the proper compartment, the optional expansion vessel kit of lt. (code 090), or the optional expansion vessel kit of lt. (code 09). (B) The Power X configurations can be completed with the flue options Ø0 mm of the section FLUES for CONDENSING BOILERS of the International Product Catalogue. As an alternative, you can use the concentric flue options Ø0/00 mm (by purchasing the flue adapter kit from Ø0-0 to Ø0/00, code 000) or the concentric flue options Ø0/ mm (by purchasing the flue adapter kit from Ø0-0 to Ø0/ code 0009). In both cases, the accessory air-intake kit B, code 00, is not necessary. In case of use of the concentric flue ranges Ø0/00 or Ø0/, with flue exit from the back side wall of the boiler, via a 90 bend, it is necessary to purchase the rear spacer frame kit, code 00 (, mm depth). (C) Inside the R.S.I. models of Power X range, the -way valve for DHW tank management is already built-in (like in this condiguration).

WALL-HUNG APPLICATIONS POWER X 0 CONFIGURATION FOR CENTRAL HEATING ONLY 09 0 00 00,, 9 BOILERS CODE Q.TY 0 Power X 0 (A) HYDRAULIC COMPONENTS and SAFETY DEVICES 00 Hydraulic manifold for safety kit (B) 00 Safety kit (B) CODE Q.TY - 009 Gas safety cut-off valve 00kW (B) 00 Hydraulic header separator for single applic. FLUES / AIR INTAKE 00 Air-intake kit B (C) (A) Inside the Power X 0, it is possible to insert, in the proper compartment, the optional expansion vessel kit of lt. (code 090) or the optional expansion vessel kit of lt. (code 09). (B) Optional safety component, according to I.N.A.I.L. Italian Safety Certification Institute (mandatory only on the Italian market). (C) The Power X configurations can be completed with the flue options Ø0 mm of the section FLUES for CONDENSING BOILERS of the International Product Catalogue. As an alternative, you can use the concentric flue options Ø0/00 mm (by purchasing the flue adapter kit from Ø0-0 to Ø0/00, code 000) or the concentric flue options Ø0/ mm (by purchasing the flue adapter kit from Ø0-0 to Ø0/ code 0009). In both cases, the accessory air-intake kit B, code 00, is not necessary. In case of use of the concentric flue ranges Ø0/00 or Ø0/, with flue exit from the back side wall of the boiler, via a 90 bend, it is necessary to purchase the rear spacer frame kit, code 00 (, mm depth).

WALL-HUNG APPLICATIONS POWER X 0 CONFIGURATION FOR CENTRAL HEATING AND DHW TANK (WITH EXTERNAL -WAYS VALVE) 09, 0 00 00, BOILERS CODE Q.TY 0 Power X 0 (A) HYDRAULIC COMPONENTS and SAFETY DEVICES 00 Hydraulic manifold for safety kit (B) 00 Safety kit (B) - 009 Gas safety cut-off valve 00kW (B) CODE Q.TY 00 Hydraulic header separator for single applic. FLUES / AIR INTAKE 00 Air-intake kit B (C) ACCESSORIES FOR DHW TANK 00 -way valve kit for DHW tank - 009 Well probe for DHW tank (A) Inside the Power X 0, it is possible to insert, in the proper compartment, the optional expansion vessel kit of lt. (code 090) or the optional expansion vessel kit of lt. (code 09). (B) Optional safety component, according to I.N.A.I.L. Italian Safety Certification Institute (mandatory only on the Italian market). (C) The Power X configurations can be completed with the flue options Ø0 mm of the section FLUES for CONDENSING BOILERS of the International Product Catalogue. As an alternative, you can use the concentric flue options Ø0/00 mm (by purchasing the flue adapter kit from Ø0-0 to Ø0/00, code 000) or the concentric flue options Ø0/ mm (by purchasing the flue adapter kit from Ø0-0 to Ø0/ code 0009). In both cases, the accessory air-intake kit B, code 00, is not necessary. In case of use of the concentric flue ranges Ø0/00 or Ø0/, with flue exit from the back side wall of the boiler, via a 90 bend, it is necessary to purchase the rear spacer frame kit, code 00 (, mm depth).

FREE-STANDING APPLICATIONS POWER X 0 DEP R.S.I. / POWER X 0 R.S.I. CONFIGURATION FOR CENTRAL HEATING AND DHW TANK 09 9 9,,, 00 00 0 CODE Q.TY CODE Q.TY BOILERS 0 Power X 0 DEP R.S.I. (A) HYDRAULIC COMPONENTS and SAFETY DEVICES 00 Taps for system 00 Hydraulic header separator for single applic. 9 0 Connection kit for DHW tank return FLUES / AIR INTAKE 00 Air-intake kit B (B) ACCESSORIES FOR DHW TANK (C) - 009 Well probe for DHW tank SUPPORTS FOR FREE-STANDING APPLICATION 000 Power X rig 000 Rear mounting kit for free-standing applic. (D) (A) The configuration illustrated in this page can be applicated also with POWER X 0 R.S.I. (code 0). Inside the Power X boilers range (except for Power X R.S.I.), it is possible to insert, in the proper compartment, the optional expansion vessel kit of lt. (code 090), or the optional expansion vessel kit of lt. (code 09). (B) The Power X configurations can be completed with the flue options Ø0 mm of the section FLUES for CONDENSING BOILERS of the International Product Catalogue. As an alternative, you can use the concentric flue options Ø0/00 mm (by purchasing the flue adapter kit from Ø0-0 to Ø0/00, code 000) or the concentric flue options Ø0/ mm (by purchasing the flue adaptor kit from Ø0-0 to Ø0/ code 0009). In both cases, the accessory air-intake kit B, code 00, is not necessary. (C) Inside the R.S.I. models of Power X range, the -ways valve for DHW tank management is already built-in (like in this condiguration). (D) In case you don t need a free-standing application and you wish to anchor the Power X rig to the wall, you don t need to purchase the rear mounting kit, code 000 (ref. ).

FREE-STANDING APPLICATIONS POWER X 0 CONFIGURATION FOR CENTRAL HEATING ONLY 09, 00 00 9 0 9, 0 BOILER CODE Q.TY 0 Power X 0 (A) HYDRAULIC COMPONENTS and SAFETY DEVICES 00 Hydraulic manifold for safety kit (B) 00 Safety kit (B) - 009 Gas safety cut-off valve 00kW (B) CODE Q.TY 00 Hydraulic header separator for single applic. FLUES / AIR INTAKE 00 Air-intake kit B (C) SUPPORTS FOR FREE-STANDING APPLICATION 000 Power X rig 000 Rear mounting kit for free-standing applic. (D) (A) Inside the Power X 0, it is possible to insert, in the proper compartment, the optional expansion vessel kit of lt. (code 090) or the optional expansion vessel kit of lt. (code 09). (B) Optional safety component, according to I.N.A.I.L. Italian Safety Certification Institute (mandatory only on the Italian market). (C) The Power X configurations can be completed with the flue options Ø0 mm of the section FLUES for CONDENSING BOILERS of the International Product Catalogue. As an alternative, you can use the concentric flue options Ø0/00 mm (by purchasing the flue adapter kit from Ø0-0 to Ø0/00, code 000) or the concentric flue options Ø0/ mm (by purchasing the flue adapter kit from Ø0-0 to Ø0/ code 0009). In both cases, the accessory air-intake kit B, code 00, is not necessary. (D) In case you don t need a free-standing application, but you wish to anchor the Power X rig to the wall, you don t need to purchase the rear mounting kit for free-standing installation, code 000, (ref. ).

FREE-STANDING APPLICATIONS POWER X 0 CONFIGURATION FOR CENTRAL HEATING AND DHW TANK (WITH EXTERNAL -WAY VALVE) 09 9, 0, 00 00 0 BOILER CODE Q.TY 0 Power X 0 (A) HYDRAULIC COMPONENTS and SAFETY DEVICES 00 Hydraulic manifold for safety kit (B) 00 Safety kit (B) - 009 Gas safety cut-off valve 00 kw (B) 00 Hydraulic header separator for single applic. FLUES / AIR INTAKE CODE Q.TY 00 Air-intake kit B (C) ACCESSORIES FOR DHW TANK 00 -way valve kit for DHW tank - 009 Well probe for DHW tank SUPPORTS FOR FREE-STANDING APPLICATION 000 Power X rig 000 Rear mounting kit for free-standing applic. (D) (A) Inside the Power X 0, it is possible to insert, in the proper compartment, the optional expansion vessel kit of lt. (code 090) or the optional expansion vessel kit of lt. (code 09). (B) Optional safety component, according to I.N.A.I.L. Italian Safety Certification Institute (mandatory only on the Italian market). (C) The Power X configurations can be completed with the flue options Ø0 mm of the section FLUES for CONDENSING BOILERS of the International Product Catalogue. As an alternative, you can use the concentric flue options Ø0/00 mm (by purchasing the flue adapter kit from Ø0-0 to Ø0/00, code 000) or the concentric flue options Ø0/ mm (by purchasing the flue adapter kit from Ø0-0 to Ø0/ code 0009). In both cases, the accessory air-intake kit B, code 00, is not necessary. (D) In case you don t need a free-standing application and you wish to anchor the Power X rig to the wall, you don t need to purchase the rear mounting kit, code 000 (ref. ). 9

_ ERP EN - 0/ SCAN AND DISCOVER Power X Trading Address: Via Risorgimento, /A 900 LECCO (LC) Italy Tel. +9 0 Fax +9 0 info@berettaboilers.com www.berettaboilers.com In order to improve its products, Beretta reserves the right to modify the characteristics and information shown in this brochure at any time and without advance warning. This brochure, therefore, cannot be considered as contractually binding on third parties.