SafeSite LED Area Light - IECEx / ATEX for Indoor and Outdoor Hazardous Areas. Patent Pending

Similar documents
SafeSite LED Area Light - ATEX / IECEx. for Indoor and Outdoor Industrial Applications

DuroSite LED High Bay - UL for Indoor and Outdoor Industrial Applications. Patent Pending

DuroSite LED End-to-End Linear Fixture - CE. for Indoor and Outdoor Industrial Applications

DuroSite LED End-to-End Linear Fixture - CE. for Indoor and Outdoor Industrial Applications

DuroSite LED End-to-End Linear Fixture - UL / CSA for Indoor and Outdoor Industrial Applications

Operating Instructions

DuroSite LED RTO Area Light - UL / CSA. for Indoor and Outdoor Industrial Applications #

ARRAN LED LED FLOODLIGHT. Standard Specification. Features

DuroSite Series LED High Bay - UL for Indoor and Outdoor Industrial Applications. Patent Pending

Dialight. DuroSite LED Linear Fixture - CE. for Indoor and Outdoor Industrial Applications

Vigilant LED Based Obstruction Lights

HDL106 LED LUMINAIRES. For Harsh & Hazardous Environments.

Vigilant LED Based Obstruction Lights

EVL-B - Zone 1, 2, 21, 22 - Replaces traditional discharge lamps more than 400W - Saves in energy, maintenance and installation

Explosion Proof LED Light - Equivalent to Watt HID C1D2, UL Listed

High bay LED lighting fixture

26 Watt Explosion Proof Low Profile LED Fixture - 3,380 Lumens - Class 1 & 2 Div 1 & 2 - ATEX / IECE

CCA-03EX. - Easy installation - Low energy consumption - New COB LED technology - Zone 1, 2, 21, 22. Directional LED spotlights

60W Flameproof LED Emergency Linear Fixture V AC - (2) 30W LED Lamps - ATEX/IECEx

Evolve LED Garage Light

SPARTAN SPX-HPBY LED Zone 1 Bay Light - IIB Applications

INERIS 01ATEX0060 (standard) TR CU (marking upon request, ordering code to be required)

Dialight LED Area Light. Product Brochure - UL

DuroSite TM LED High Bay. for Industrial & Commercial Applications.

25W Explosion Proof Surface Mount LED Light - C1D1-2 - C2D1-2 - Aluminum Frame V AC

208W Explosion Proof Low Profile LED - Emergency Backup - 27,040 Lumens - C1&2 D1&2 - ATEX /IEC

PRODUCT OVERVIEW. Light fittings, boxes & custom built control panels for explosive atmospheres

Vaya Linear LP, White & Mono

DTS Light fittings for explosive atmospheres

150W Explosion Proof High Bay LED Light Fixture - C1D1&2 - C2D1&2-17,500 Lumens - 60 Beam

25W Hazardous Location Integrated LED Light Fixture Lumens - Low Profile - ATEX IEC CSA UL

Vigilant LED Based Obstruction Lights

Operating Instructions

Explosion Proof 70 Watt Low Profile LED Light Fixture Lumens - C1D1 Group B - Hydrogen Rated

C2D1/C1D2 Explosion Proof 50 Watt LED Light Fixture - Paint Spray Booth Approved - 6,250 Lumens

100W Explosion Proof Low Bay AC LED Fixture - C1D1 - C2D1 - Group B + ATEX/IECEX - IP67 Waterproof

C1D1 Explosion Proof 50W LED Flood Light Fixture - Paint Spray Booth Approved - Adj Surface Mount

Champ VMV LED Series Luminaires Leading the way in LED technology for industrial and hazardous applications. Now cul Listed!

Enhancing Safety + Productivity. Champ VMV LED Series Luminaires Leading the way in LED technology for industrial and hazardous applications

Hazardous Area LED Lighting Hazard Gard LED Luminaires. Hazard Gard EVLL LED

Pro Series LED Lighting Champ LED floodlights. Champ Pro Series. LED floodlights for heavy industrial

OLUX LED Flood Light OSRAM. Datasheet APPLICATIONS.

Class 1 Div 2 LED Pivoting Light - 2 foot 2 lamp - LED T series Style V Dimmable

Albeo LED Luminaire. Heavy Industrial Low Bay Lighting. (ALR1 - Series)

Applications. Standard Materials

Dimmable General Area Use High Bay 320 Watt LED Light Fixture - Low Profile - High Efficiency

TRMUNV220ACXXXA UNIVERSAL VOLTAGE HIGHBAY RETROFIT KIT

120W Hazardous Location LED Fixture V DC - Modbus TCP/IP - Network Controlled - Dimmable

LUXCOMFO TM LED Flood Light Datasheet

Trusted worldwide since 1989 INTRINSICALLY SAFE RANGE

Specification Sheet. Certificates. Features. Application. Anti-Explosive Lamp

Dialight LED Area Light. Product Brochure - UL

NATELA 5. Based on 30 PRODUCT SPECIFICATIONS PRODUCT FEATURES PHOTOMETRIC DATA LIGHT DISTANCE CURVE 22W LINEAR WALL WASHER

50W Explosion Proof Trunnion Mount Compact LED Flood Light - C1D2, C2D1 - Paint Spray Booth Approved

40W Explosion Proof LED Light Fixture - C1D1, C2D1-2x2 Lay-in Troffer - ATEX/ISO Rated

LHB LED High Bay. Technical Specifications. Description. Performance Data. Dimensions & Weights. Delivered Lumens Efficacy.

OLUX LED IN-GROUND OSRAM. Datasheet

INTRINSICALLY SAFE LIGHTING RANGE

LED Panel Light E830J

Dimensions (111mm) 3 (76mm) (111mm) (48mm)

Engineering Safety & Productivity. Champ FMV LED Series Floodlight Fixtures Leading the way in LED technology for harsh and hazardous area usage

Dimensions (111mm) (111mm) 3 (76mm)

SDL4 LED Strip Diffused Lens

Low Profile Clean Room 150W LED Light - 2x2 Lay-In Troffer C1D1 - C2D2 - ISO 14644/FS-209E

Capella 2. Project Name. Construction. Optical System. Product Applications. Housing and lens frame are constructed from heavy-duty low

300W Low Profile Clean Room LED Light - LED Signal Light - C1D1 - C2D2 - ISO 14644/FS-209E Rated

BAS SDL8' LED Strip Diffused Lens

BC9700 series High Power LED Explosion Proof Light

EVLED201 36W Led Luminaire. Descriptions. Manufacturer Information. Packaging Carton 1 Weight Per each 14.85

Technical Application Guide for UP-SHINE LED Track Light

XLFE-4/1. Borosilicate glass globe

EWL. Supporting bracket

Explosion Proof LED Light - Equivalent to Watt Metal Halide - Class 1 Division 2

GRP Flameproof Combination Signal db(a) / 5 Joule Series YL6S

100W Explosion Proof Ultraviolet Portable LED Fixture - 365NM - EXP Cord Caps - 150ft Cord

elevated ambient capability. in installations where moisture, dirt, dust, vibration, corrosion and rough usage are problems.

Hazardous Location LED Pivoting Light - C1D2 - Dimmable - Modbus TCP/IP Network - Meets USCG Specs

PRECISION LIGHTING FOR PRISTINE MOMENTS!

Ex LED light fittings

150W Explosion Proof LED Flood Light - Surface Mount Lumens - C1D V AC

CATALOG NUMBER NAME DESCRIPTION HTL X Keeper 2 40 Watts 120v 5000K 4,000 Lm HTL X Keeper 2 40 Watts 277v 5000K 4,000 Lm 4.

50W Explosion Proof LED Light - C1D2, C2D1 - Replacement for 150W Metal Halide - Globe/Guard

Enhancing Safety + Productivity. Champ VMV LED Series Luminaires Leading the way in LED technology for industrial and hazardous applications

Hubbell Harsh & Hazardous. Our Brands. Corporate Information

ASPECT VISION DELIVERED

Hubbell Harsh & Hazardous. Our Brands. Corporate Information

SL2210 SAMSUNG GU10 LED Lamp RECESSED LED DOWNLIGHTS

LED lighting for light industrial areas IHB series high bay LED luminaires. IHB series. High bay LED luminaires for light industrial areas

Flameproof Manual Call Points Series MCP

Ex Mark:Ex d eb ⅡB T6 Gb

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS PENTAIR CLEAN AIR SYSTEMS

Illumination unit For sight glass level indicator Model LGI

POINT HELIDECK LIGHTS PRL-EX-LSM LED v4 CLASS I, DIVISION 2 & ZONE 2

Canadian Model Number Designations. Models ending in... LED-8030M42 C-A = 347V LED-8030M42 -A = 120/277V LED-8030M42 C = 120/347V

150 Watt Explosion Proof LED Light - 5' Tall Base Stand Mount - 24 Inch Stand - Class I Div 1 C&D

LED HIGH BAY LINEAR ECO SERIES

Technical application guide

Flow LED robust and streamlined

Flow LED robust and streamlined

80W C1D2 Hazardous Location Integrated LED - Corrosion Resistant for Marine - Emergency Backup

Transcription:

SafeSite LED Area Light - IECEx / ATEX for Indoor and Outdoor Hazardous Areas

About Dialight Dialight (LSE: DIA.L) is leading the energy efficient LED lighting revolution around the world for industrial and hazardous areas as well as transportation and infrastructure applications. For 40 years it has been committed to the development of LED lighting solutions that enable organisations to vastly reduce energy use and maintenance needs, improve safety, ease disposal and reduce CO 2 emissions. Value Proposition Improve safety, colour quality Better temperature rating (T-rating) Lower total cost of ownership, quick ROI Lower energy consumption by > 50% Significantly reduce CO 2 emissions History at a Glance 1938 Dialight founded in Brooklyn, NY 1971 LED circuit board indicator 1994 LED transit behicle signals 1995 LED traffic signals 2000 FAA certified LED Obstruction Lights 2007 LED lighting for hazardous locations 2009 LED High Bay fixtures 2012 Full performance 10-year warranty 2013 Controls for LED Lighting 2014 125 lumens per watt 2015 140 lumens per watt SafeSite LED lighting for hazardous locations Vigilant LED lighting for general Industrial locations DuroSite LED lighting for general Industrial locations Vertically Focused Regulated Primary Markets Oil, Gas & Petrochemical Power Generation Mining Chemical Pharmaceutical Water Treatment Food & Beverage Secondary Markets Manufacturing Warehousing Cold Storage Data Centers

SafeSite LED Area Light IECEx / ATEX - Zone 1, 21 Application: The SafeSite LED area light represents the future of energy efficient facility illumination for hazardous areas worldwide. The ATEX / IECEx area lighting fixture consumes at least 50% less energy compared to traditional HID light sources, while reducing maintenance and carbon emissions. This light incorporates both cutting edge LED technology along with proprietary optics to achieve area lighting comparable with other traditional light sources. Mechanical Information Fixture Weight: 9.53kg (21lb) Shipping Weight: 10.43kg (23lb) 219 292 Mounting: Supplied with stirrup mounting bracket 150 Wiring: Factory installed 3 meter 3 core armored cable Electrical specifications Certifications Ex II 2GD Ex d IIC T4 Gb (Ta = -40 C to +65 C) Ex t IIIC T135 C Db IP 6X (Ta = -40 C to +65 C) Ex II 2GD Ex d IIC T5 Gb (Ta = -40 C to +42 C) Ex t IIIC T100 C Db IP 6X (Ta = -40 C to +42 C) Certificate numbers: IECEx SIR 11.0156 SIRA 11ATEX1357 ATEX Zones 1, 21 ATEX Zones 2, 22 ABS Design Assessed: 13-HS1043210C-PDA IP 66 RoHS compliant IK08 impact rating Dimensions in mm Features & Benefits L70 rated for >100,000 hours @ 25 C ambient 5 year full performance warranty Instant on/off operation Universal input (110-277V AC), 50/60Hz Superior colour rendering index compared to HPS, LPS, MV Mercury free Resistant to shock and vibration Temperature compensation technology for longer life Factory sealed Operating Voltage: Power Consumption: 110-277V AC, 50/60 Hz See table Operating Temp: -40 C to +65 C (-40 F to +149 F) Surge Protection: THD: <20% Power Factor: > 0.9 Construction Housing: Finish: Lens: Photometric Information CRI: 75 CCT: 1 kv line to line 2 kv line to ground Powder coated A360 alum. Polyester / epoxy powder coat gray RAL 7040 for superior corrosion resistance Toughened glass 5,000K (cool white) 4,000K (neutral white) Optics: IES Files: 180 and 360 distribution available Available upon request All values typical unless otherwise stated All lumen values are typical (tolerance +/- 10%)

SafeSite LED Area Light with Junction Box IECEx / ATEX - Zone 1, 21 Application: The SafeSite LED area light represents the future of energy efficient facility illumination for hazardous areas worldwide. The ATEX /IECEx area lighting fixture consumes at least 50% less energy compared to traditional HID light sources, while reducing maintenance and carbon emissions. This light incorporates both cutting edge LED technology along with proprietary optics to achieve area lighting comparable with other traditional light sources. Mechanical Information 296 Fixture Weight: Shipping Weight: Mounting: Wiring: Electrical specifications 9.07kg (20lb) 9.98kg (22lb) Supplied with stirrup mounting bracket Factory installed junction box Certifications Ex II 2GD Ex d IIC T4 Gb (Ta = -20 C to +65 C) Ex II 2GD Ex d IIC T5 Gb (Ta = -20 C to +42 C) Ex t IIIC T135 C Db IP 6X (Ta = -20 C to +65 C) Ex t IIIC T100 C Db IP 6X (Ta = -20 C to +42 C) -40 C variants available for all the above Certificate numbers: IECEx SIR 11.0156 SIRA 11ATEX1357 ATEX Zones 1, 21 ATEX Zones 2, 22 IP66 RoHS compliant IK08 impact rating 246 Features & Benefits L70 rated for >100,000 hours @ 25 C ambient 5 year full performance warranty Instant on/off operation Universal input (110-277V AC), 50/60Hz Superior colour rendition index compared to HPS, LPS, MV Mercury free Resistant to shock and vibration Temperature compensation technology for longer life Factory sealed Dimensions in mm) Operating Voltage: Power Consumption: 110-277V AC, 50/60 Hz See table Operating Temp: -40 C to +65 C (-40 F to +149 F) Surge Protection: THD: <20% Power Factor: > 0.9 Construction Housing: Finish: Lens: Photometric Information CRI: 75 CCT: Optics: 1 kv line to line 2 kv line to ground Powder coated A360 alum. Polyester / epoxy powder coat gray RAL 7040 for superior corrosion resistance Toughened glass 5,000K (cool white) 4,000K (neutral white) 180 and 360 distribution available IES Files: Available upon request All values typical unless otherwise stated All lumen values are typical (tolerance +/- 10%)

SafeSite LED Area Light IECEx / ATEX Zone 2, 22 Application: The SafeSite LED area light represents the future of energy efficient facility illumination for hazardous areas worldwide. The ATEX / IECEx area lighting fixture consumes at least 50% less energy compared to traditional HID light sources, while reducing maintenance and carbon emissions. This light incorporates both cutting edge LED technology along with proprietary optics to achieve area lighting comparable with other traditional light sources. Mechanical Information Fixture Weight: 7.5kg (16.5lb) 301 (11.8) 202 (7.9) Shipping Weight: Mounting: 8.16kg (18.5lb) Supplied with stirrup mounting bracket 176 (6.9) Wiring: Factory installed 3 meter 3 core armored cable Electrical specifications Dimensions in mm (inches) Certifications Ex II 3GD Ex na nc IIC T4 Gc [Ta = -40C to +65C] Ex tc IIIC T130C Dc [Ta = -40C to +65C] Certificate numbers: IECEx SIR 14.0042X Sira 14ATEX4097X ATEX Zones 2, 22 IP 66 RoHS compliant Features & Benefits L70 rated for >100,000 hours @ 25 C ambient 5 year full performance warranty Instant on/off operation Universal input (110-277V AC), 50/60Hz Superior colour rendering index compared to HPS, LPS, MV Mercury free Resistant to shock and vibration Temperature compensation technology for longer life Factory sealed Operating Voltage: Power Consumption: 110-277V AC, 50/60 Hz See table Operating Temp: -40 C to +65 C (-40 F to +149 F) Surge Protection: THD: <20% Power Factor: > 0.9 Construction Housing: Finish: Lens: Photometric Information 1 kv line to line 2 kv line to ground Powder coated A360 alum. Polyester / epoxy powder coat gray RAL 7040 for superior corrosion resistance Toughened glass CRI: 75 CCT: Optics: IES Files: 5,000K (cool white) 4,000K (neutral white) 180 and 360 distribution available Available upon request All values typical unless otherwise stated All lumen values are typical (tolerance +/- 10%)

SafeSite LED Area Light with Junction Box IECEx / ATEX Zone 2, 22 Application: The SafeSite LED area light represents the future of energy efficient facility illumination for hazardous areas worldwide. The ATEX / IECEx area lighting fixture consumes at least 50% less energy compared to traditional HID light sources, while reducing maintenance and carbon emissions. This light incorporates both cutting edge LED technology along with proprietary optics to achieve area lighting comparable with other traditional light sources. 80 (3.1) Mechanical Information Fixture Weight: Shipping Weight: 7.67kg (16.9lb) 8.57kg (18.9lb) 301 (203) 206 (8.1) Mounting: Wiring: Supplied with stirrup mounting bracket Factory installed junction box Electrical specifications Dimensions in mm (inches) Certifications Ex II 3GD Ex na nc IIC T4 Gc [Ta = -40C to +65C] Ex tc IIIC T130C Dc [Ta = -40C to +65C] Certificate numbers: IECEx SIR 14.0042X Sira 14ATEX4097X ATEX Zones 2, 22 IP 66 RoHS compliant Features & Benefits L70 rated for >100,000 hours @ 25 C ambient 5 year full performance warranty Instant on/off operation Universal input (110-277V AC), 50/60Hz Superior colour rendering index compared to HPS, LPS, MV Mercury free Resistant to shock and vibration Temperature compensation technology for longer life Factory sealed Operating Voltage: Power Consumption: 110-277V AC, 50/60 Hz See table Operating Temp: -40 C to +65 C (-40 F to +149 F) Surge Protection: THD: <20% Power Factor: > 0.9 Construction Housing: Finish: Lens: Photometric Information 1 kv line to line 2 kv line to ground Powder coated A360 alum. Polyester / epoxy powder coat gray RAL 7040 for superior corrosion resistance Toughened glass CRI: 75 CCT: Optics: IES Files: 5,000K (cool white) 4,000K (neutral white) 180 and 360 distribution available Available upon request All values typical unless otherwise stated All lumen values are typical (tolerance +/- 10%)

SafeSite LED Area Light Ordering Information Part Number Optical Pattern 1 Colour 2 Lumens Watts Lumens Per Watt Junction Box Multi Area Light IECEx / ATEX Zone 1, 21 HZA0C2N 180 Cool White 2,200 21 105 HZA1C2N 360 Cool White 2,200 21 105 HZA2C2N 180 Cool White 3,600 38 95 HZA3C2N 360 Cool White 4,000 38 105 HZA4C2N 180 Cool White 4,600 47 97 HZA5C2N 360 Cool White 5,100 47 108 HZA8C2N 180 Cool White 5,600 58 97 HZA9C2N 360 Cool White 6,000 58 103 IECEx / ATEXZone 1, 21 - Junction Box HZJA8C2N 180 Cool White 5,600 58 96 HZJA9C2N 360 Cool White 6,000 58 103 HZJA8C2N-2 180 Cool White 11,200 116 96 2 HZJA9C2N-2 360 Cool White 12,000 116 103 2 HZJA8C2N-3 180 Cool White 16,800 174 96 3 HZJA9C2N-3 360 Cool White 18,000 174 103 3 IECEx / ATEX Zone 2, 22 HZB0C2N 180 Cool White 2,000 21 95 HZB1C2N 360 Cool White 2,500 21 105 IECEx / ATEX Zone 2, 22 - Junction Box HZJB0C2N 180 Cool White 2,000 21 95 HZJB1C2N 360 Cool White 2,500 21 119 HZJB2C2N 180 Cool White 3,000 38 78 HZJB3C2N 360 Cool White 3,500 38 92 HZJB4C2N 180 Cool White 5,000 47 106 HZJB5C2N 360 Cool White 5,500 47 117 HZJB8C2N 180 Cool White 6,000 58 103 HZJB9C2N 360 Cool White 6,500 58 112 HZJBEC2N 180 Cool White 7,000 68 102 HZJBFC2N 360 Cool White 7,500 68 110 1 180 optical pattern models are optimized for a 45 mounting angle 2 Part numbers listed in the above table are cool white. For neutral white models replace the first C in the part code with an N Ex: HZA2C2N becomes HZA2N2N 3 When changing to neutral white there is an approximate 7% drop in lumen output Light Distribution Patterns 180 light distribution 360 light distribution

SafeSite LED Area Light Dimensions with Stirrup Bracket Zone 1 59 (2.3) 90 219 292 64 (2.5) 35 (1.4) 150 114 281 (4.5) STIRRUP BRACKET FIXING POSITIONS Supplied with Stirrup Mounting bracket as shown Dimensions in mm (Inches) Zone 1 with Junction Box Junction Box Multi Area Light x 2 Multi Area Light x 3 Dimensions in mm Zone 2 272 (10.7) 176 (6.9) 301 (11.8) 202 (7.9) 246 (9.7) Dimensions in mm (Inches) Zone 2 with Junction Box 80 (3.1) 301 (11.8) 206 (8.1) 246 (9.7) 272 (10.7) Dimensions in mm (Inches) Dialight reserves the right to make changes at any time in order to supply the best product possible. The most current version of this document will always be available at: /Assets/Brochures_And_Catalogs/Illumination/MDTFHZSALEUX001.pdf. Warranty Statement: EXCEPT FOR THE WARRANTY EXPRESSLY PROVIDED FOR [HEREIN/ABOVE/BELOW], DIALIGHT DISCLAIMS ANY AND ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, WITHOUT LIMITATION, ANY WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, TITLE, AND NONINFRINGEMENT. MDTFHZSALEUX001_G