Selecting a Safe Tank Gauging Product. Understanding Hazardous Area Definitions for Equipment Approvals

Similar documents
A guide to the use of electrical equipment in potentially explosive atmospheres To view this document in PDF format click here.

Airo Wireless Intrinsically Safe White Paper. Written By: David Schmitt

Guide for hazardous areas

[ TECHNOLOGY ] and does this definition affect a burner.

UL HAZARDOUS LOCATIONS SERVICES

S T R I T T & P R I E B E I N C.

Beamex. Calibration White Paper. Calibration in hazardous areas

REGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC

Beamex Calibration White Paper. Calibration in hazardous areas

Hazardous Area Classification in Oil & Gas Industry. A Fire Prevention Tool

Tank Gauging Products for Bulk Liquid Storage Tanks. Simple, Safe and Reliable Inventory Measurement

Drive Technology \ Drive Automation \ System Integration \ Services * _0817* Inquiry Forms for Explosion-Proof Gearmotors

Overview of Hazardous Locations as They Relate to Solenoid Valves

ATEX GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres. Directive 94/9/EC

A GUIDE TO EUROPEAN (EEC) CERTIFICATION FOR ELECTRICAL EQUIPMENT IN HAZARDOUS AREAS

HAZARDOUS AREA CLASSIFICATION AND SELECTION OF EQUIPMENT FOR SAFE USE THEREIN FROM AN ELECTRICAL VIEWPOINT

The R. STAHL Technology Group Worldwide Success with Competence and Customer Support

Hazardous Areas - EXPLOSIONPROOF SOLENOIDS

Introduction to Hazardous Electrical Location Classifications

Hazardous Area Classifications and Protections

Understanding Hazardous Locations Concepts

HOW TO FIND THE RIGHT DEVICE FOR YOUR FACILITY

Guide to Hazardous Location Approvals: MICRO SWITCH Hazardous Area Limit Switches

Guide to Hazardous Location Approvals:

1. GENERAL TECHNICAL INFORMATION

Guide to Intrinsically Safe Portable Radios

A Guide to Safe Electronic Weighing in Hazardous Locations

Specifying Temperature Sensors for Hazardous Areas

RE: USE OF FIREPRO IN POTENTIALLY EXPLOSIVE ATMOSPHERES

Explosion-protected actuator Page 259 of 292

Erik Leider Project Engineer Hazardous Locations, Gas & Oil Underwriters Laboratories

EtherCAT Box Modules (EPxxxx-xxxx)

ATEX, NOMENCLATURE AND CODING

Process Instrumentation. Product Guide. Registered Quality System to ISO 9001

VSD AND SS DRIVING ATEX MOTORS February 2014

Area Classification and Types of Protection for Explosive Atmospheres: A Review

ATEX, NOMENCLATURE AND CODING

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Electrical Area Classification 101 An Introduction to Area Classification the Basics IEEE Houston CED

ATEX - GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres C E R T I F I E D DANISH TECHNOLOGICAL INSTITUTE

ATEX - GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres

Products Solutions Services CT287. Hazardous Area Classifications and Protection Systems

ATEX Safety Switches. More than safety.

Desiccant. Breather Range

TRI-SERVICE ELECTRICAL WORKING GROUP (TSEWG) 07/16/08 TSEWG TP-8: ELECTRICAL EQUIPMENT ENCLOSURES AND HAZARDOUS LOCATIONS

Certification Supplement Manual

Smoke detection in hazardous areas:

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

ESSENTIAL EXPLOSION PROTECTION

WHAT WHITE PAPER IS POTENTIALLY EXPLOSIVE ATMOSPHERE CERTIFICATION AND WHY YOU. June 2010

CLASS I LOCATIONS ZONE CLASSIFICATION

Certification Supplement Manual

Hazardous area descriptions

INSTRUCTION MANUAL. E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations

Explosion-protected network cameras Safety first

Approval of Ex (Electrical) Equipment for use/installation in Hazardous Areas.

Intrinsic Safety. Intrinsically Safe Solutions. Accurate Weighing in Hazardous Areas

INSTRUCTION & SERVICE MANUAL

Annubar Flowmeter Series

Manual. WAGO-I/O-SYSTEM 750 Use in Hazardous Environments 750-xxx Definition of Terms, Marking and Installation Regulations. Version 1.0.

Phoenix Explosion-proof. Pan & Tilt heads and Camera Housings for potentially exposed environments. Answers for infrastructure.

Selection of Explosion Protected Equipment for Hazardous Locations. Compiled by: Pieter Coetzee ZONE 2 ZONE 1 ZONE 0.

Weighing Solutions for Hazardous Areas FULL COMPLIANCE WITH ATEX DIRECTIVE

August Process Industry Practices Electrical. PIP ELEHA01 Engineering Guide for Determining Electrical Area Classification

Numerical Standards Listing

CLASSIFICATION COMPARATOR

Circulation Heaters Selection Guidelines

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Phoenix Flameproof. Pan & Tilt heads and Camera Housings for potentially explosive environments.

Today's world of increasing

NCS/SAS IAS/PES Chapter Seminar January 25-27, Hazardous Locations. OBIEC Consulting George Morlidge Fluor Canada

Seat Ventilation offers an extensive range of ATEX certified products and is undertaking great efforts to extend this range even further.

Rosemount 752 Fieldbus Remote Indicator

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

Rosemount 214C Sensor. Quick Start Guide , Rev AF August 2017

Numerical Standards Listing

Certificate of Compliance

PANELBOARD PROTECTION ON A GLOBAL SCALE

Flexible Schedule of Accreditation. SIRA CERTIFICATION SERVICE Unit 6, Hawarden Industrial Park, Hawarden, CH5 3US.

INSTRUCTION MANUAL. D2xB1XH1 & D2xB1XH2 Xenon Beacons For use in Hazardous Locations

Hazardous Locations. A look at Hazardous Locations Product Certification. Presented By

Flexible Schedule of Accreditation. SIRA CERTIFICATION SERVICE Unit 6, Hawarden Industrial Park, Hawarden, CH5 3US.

FINAL ATEX REPORT ON EQUIPMENT FOR USE IN POTENTIALLY EXPLOSIVE ATMOSPHERES FOR GOLDEN PROMISE EQUIPMENT INC. FLOW MONITOR, GPE3000 SERIES,

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

Crouse-Hinds Enclosures. High performance, high reliability enclosures for global applications

Rosemount 752 FOUNDATION Fieldbus Remote Indicator

Relays for use in hazardous locations. Class I, Division 2 and ATEX

GETTING STARTED GUIDE NI TC, ±78 mv, 24 Bit, 75 S/s Aggregate

4) Intrinsic Safety Certification

standards: standards:

UL Topic III. Converting European EEx Certificates. Into. North American Division Certificates

EFP Series ( enhanced ) Flameproof Electrical Connectors for Hazardous Environments IP 68. Certified to: IIC

IS (Intrinsic safety) - Ex (Epsilon x) ATEX CENELEC

Certificate of Compliance

Numerical Standards Listing

GETTING STARTED GUIDE NI DI, 30 V, Sourcing, 7 μs

Certificate of Compliance

ELECTRICAL SAFETY Information Bulletin

SELECTION, INSTALLATION & TESTING OF ELECTRICAL EQUIPMENTS IN HAZARDOUS AREA

Electrical Installations Design, Selection, Erection and Inspection

Transcription:

Selecting a Safe Tank Gauging Product Understanding Hazardous Area Definitions for Equipment Approvals

Hazardous Area Approvals

A Worldwide Requirement There are many environmental considerations within a location that define a specific type of approval that is needed. The ATEX Directive, which is based on the International Electrotechnical Commission (IEC) standard, defines requirements within the European Union (EU). In the U.S., hazardous area requirements are defined by the National Electric Code, as set forth by the National Fire Protection Association (NFPA). Other countries may use IEC standards or have their own code of standards, such as the CEC in Canada or Russian GOST codes. Hazardous Areas are locations where the potential for fire or explosion exists because of liquids, gases, dust and materials in the atmosphere that could be easily ignited. In North America, hazardous areas are typically separated by classes, divisions and groups to define the level of safety required for equipment installed in these locations. Classes define the general form of the flammable materials in the atmosphere. Divisions define the probability of the presence of flammable materials. Groups classify the exact flammable nature of the material. The more recent NEC Standard 505 attempts to harmonize American and international classifications by using zone classifications. In Europe and countries outside of North America, zones are used to define the probability of the presence of flammable materials. Protection Types denote the safety method used for the device. Groups classify the exact flammable nature of the material, but these groups are separated differently than North American Groups. Lastly, both systems use temperature codes to identify the maximum surface temperature of the device, which ensures the specific gas or vapor encountered in the application will not ignite. Independent test laboratories perform testing and inspection before approving equipment. The Varec 6000 Servo Tank Gauge is approved by multiple laboratories to different standards required worldwide, such as explosion proof/flame proof, as well as being intrinsically safe. Ensure the equipment you select carries clear identification of the pertinent approvals standard.

Hazardous Area Approvals

Flammable Materials and Ignition Sources The application of hazardous area classification and appropriate standards is the responsibility of the end user. For detailed information, see specific standards published by the relevant organizations, for example, the American Petroleum Institute (API RP 500) provides a recommended practice for Classification of Locations for Electrical Installations at Petroleum Facilities Classified as Class I Division I and Division 2. Zones and Divisions NEC 500 hazardous locations are established into two divisions (1 & 2) based upon the presence of flammable materials under either normal or abnormal conditions, maintenance, repairs or leakage. For countries that utilize IEC or ATEX standards, three Zones (0, 1 & 2) define how often the hazard is present. The aim of NEC, ATEX and IEC standards is to achieve safety by identifying areas where ignition sources should be eliminated or ensuring that the ignition source is noneffective. ATEX and IEC separate NEC s Division 1 into two distinct zones (0 & 1). Zone 0 defines locations that are most hazardous because they continuously remain hazardous under normal conditions. Therefore, ATEX and IEC restrict the method of protection in Zone 0, while permitting a more relaxed method of protection in Zone 1 locations. Zone 0 provides a marked difference between NEC and EU/ IEC standards. Zone 1 locations can be treated as roughly equivalent to Division 1 locations and Zone 2 locations roughly equivalent to Division 2 locations. For most situations, equipment certified for use in a Zone 0 can also be installed in a Zone 1 or 2. Classes and Groups NEC 500 uses Classes (I, II, III) and Groups (A-G) to identify the specific hazard. Classes are used to represent the type of material (gases, dusts, or fibres). Groups are used to represent how ignitable a gas or gas mixture is, with A being the most ignitable and G the least ignitable. The IEC and ATEX Zone systems identify the hazard by two main groups. Group I gases are firedamp methane found in mining/underground locations and Group II are all other explosive gases found in surface industries, such as a terminal or refinery. Group II is divided into three subgroups (A, B & C) arranged in order of hazard due to threat of ignition with A being the most difficult to ignite and C the easiest to ignite. NEC 505 NEC Standard 505 (Zone classification) uses three parallel Zones (0, 1 & 2) to define location, while a single class (1) with four sub groups (A-D) are more closely aligned with EU/IEC Groups IIA, IIB and IIC. Safety standards apply to all electronic equipment and also some mechanical equipment. The Varec 2500 Automatic Tank Gauge, which is mechanically operated, but can also be connected to tank gauge transmitters is ATEX approved for use in hazardous areas. Flammable Material is Present... Continuously Intermittently Abnormally IEC & EU Zone 0 Zone 1 Zone 2 NEC 500 Division 1 Division 2 NEC 505 Zone 0 Zone 1 Zone 2 Typical Gas NEC 505, EU & IEC NEC 500 Acetylene Group IIC Class I / Group A Hydrogen Group IIB + Hydrogen Class I / Group B Ethylene Group IIB Class I / Group C Propane Group IIA Class I / Group D

Hazardous Area Approvals

Types of Protection Depending on the type of protection required for a hazardous area, a device should be selected that offers the corresponding electrical or mechanical design feature that is approved for safe operation. For applications normally encountered by Varec in tank farms, terminals and refineries - intrinsic safety, explosion proof/flame proof are the most common, but non-incendive, encapsulation, purging, oil immersion, powder filling or increased safety may also be a requirement depending on the application. Intrinsic Safety Intrinsic safety is one method of protection for devices that operate in areas with flammable gases, vapors and liquids, such as where fuels are stored and manufactured. An intrinsically safe (i.s.) specification or approval rating means that the device is incapable of releasing sufficient electrical or thermal energy to cause ignition of the most easily ignited concentration of gas present. This type of protection is referred to by IEC as Ex i., by NEC (500) as IS and NEC (505) as AEx i. Explosion Proof and Flame Proof Both Explosion Proof and Flame Proof are used to define the ability of a device enclosure to withstand an explosion and restrict the propagation of the explosion. The certification takes into account the enclosure s ability to restrict the flame path, the ignition energies of the gas, the volume of the enclosure and the normal operating temperature. When all factors are considered, if a gas or vapor ignited within the device, the explosion would need to be contained internally. The IEC Zone system does not allow this flameproof methodology in Zone 0. This type of protection is referred to as Ex d by IEC, XP by NEC 500 and AEx d by NEC 505. Explosion/Flame proof and intrinsic safety concepts can be combined for a single device. The Varec 4590 Tank Side Monitor (TSM) is approved as a Flame proof device that is also intrinsically safe. The 4590 TSM also acts as an intrinsically safe power supply for connected devices, such as radar tank gauges, temperature and pressure sensors. Protection Type NEC 505, EU & IEC IEC Standards NEC 500 Intrinsic Safety Ex i EN 60079-11 (IS) Non-incendive - (NI) Non Sparking Ex na / AEx na EN 60079-15 Explosion Proof - (XP) Flame Proof Ex d / AEx d EN 60079-1

Hazardous Area Approvals

Ambient Environmental Considerations In addition to approvals requirements, consider the ambient atmosphere of the application to ensure that the equipment selected will perform in the environment for which it is intended. Many environments are arduous and may involve the equipment being subject to extreme high or low temperatures, demanding weather conditions, immersion in water or chemical/corrosive attack. Ingress Protection (NEMA) Ingress Protection (IP) specified by IEC provide rates for the environmental (physical) protection an enclosure provides to its internal components from solids, liquids, gases and physical impacts. The American version of IP rating is known as NEMA, but because the tests and evaluations for characteristics are not identical, the IEC classification cannot be exactly equated with NEMA Enclosure Type Numbers. Approximate NEMA Rating Equivalent to IP NEMA rating IP Equivalent 1 10 2 11 3 54 Temperature Ratings and Codes A mixture of hazardous gases and air may ignite when coming in contact with a hot surface. The condition for ignition depends on several factors, such as surface area, temperature and concentration of gas. If the equipment s T rating signifies the temperature generated by the equipment is greater than the ignition temperature of the gas present, the equipment will ignite the surrounding atmosphere and cause an explosion. The T ratings of the EU, IEC and NEC are, in all practicality, the same. The device your application demands may not be approved for use in a hazardous area. In these cases, it may be possible to install your device in an optional enclosure or case that is approved and provides the required protection. The Varec 8130 Remote Terminal Unit is normally installed in non-hazardous areas, such as control rooms, but it is also approved for use in Class 1, Division 2 areas when installed in an optional NEMA 4 enclosure. 3R 14 3S 54 4 & 4X 55 5 52 6 & 6P 67 12 & 12K 52 13 54 Ingress Protection Codes (IPxy) Character x=solids y=liquids 0 None No Protection 1 Objects > 50 mm Vertical (90 ) Dripped Water 2 Objects > 12 mm Dripped Water (75 to 90 ) 3 Objects > 2.5 mm Sprayed Water (30º to 90º) 4 Objects > 1 mm Splashed Water (0º to 90º) 5 Dust Protected Low Pressure Water Jets 6 Dust-tight High Pressure Water Jets 7 Immersion to 1 m (3 ft) 8 Immersion beyond 1 m (3 ft) Maximum Surface Temperature Temperature Class NEC 505, EU & IEC NEC 500 842 F 450 C T1 T1 572 F 300 C T2 T2 536 F 280 C T2A 500 F 260 C T2B 446 F 230 C T2C 419 F 215 C T2D 392 F 200 C T3 T3 356 F 180 C T3A 329 F 165 C T3B 320 F 160 C T3C 275 F 135 C T4 T4 248 F 120 C T4A 212 F 100 C T5 T5 185 F 85 C T6 T6

Measurement, Control and Automation Varec, Inc., deliver measurement, control and automation solutions and professional services for most major oil companies, defense organizations and airlines worldwide. Varec s FuelsManager software applications and hardware products provide local level management and enterprise visibility of liquid petroleum assets at bulk storage facilities, marketing terminals, refineries, petrochemical plants and military fuel facilities. Oil & Gas Since its founding in 1928, Varec has been a leading innovator in the petroleum and chemical sectors, delivering automated systems and professional services for tank farm, terminal and refinery operators and owners worldwide. Today Varec provides completely integrated measurement, control and automation solutions that are specifically designed to ensure safe storage and distribution, track product visibility and provide accurate accounting for the local facility operator to the corporate enterprise. This includes functionality for: Tank gauging and inventory management Supervisory control and data acquisition (SCADA) Overfill prevention, facility monitoring and release detection Terminal and refinery automation Defense Defense operations need a fieldproven fuels management system for real-time, global inventory visibility and accountability. Varec s commercial off-the-shelf solution provides mission critical functionality that is essential to air, ground and marine fueling applications at the base, tactical command or enterprise levels. This includes functionality for: Transaction and inventory management Supervisory control and data acquisition (SCADA) Automatic tank gauging Dispatch and automated data capture (ADC) Aviation Varec provides aviation application services designed for airports, airlines and service providers. The entire aviation industry can now rely on a single solution for aviation fuels management from the fuel farm to take-off. This includes functionality for: Remote or automated, real-time dispatch operations Online or batch-mode paperless fuel ticketing Integrated fuel farm and supervisory control and data acquisition (SCADA) automation Local fuels reconciliation (ExSTARS compliant) Aircraft Communication Addressing and Reporting System (ACARS) messaging and airlines systems integration Enterprise solutions (FuelsManager Aviation Application Services) Varec, Inc. Locations Corporate Headquarters 5834 Peachtree Corners East Norcross (Atlanta), GA 30092 USA Tel: +1 (770) 447-9202 Toll Free: +1 (866) 698-2732 Fax: +1 (770) 662-8939 Houston 5151 San Felipe Sage Plaza, Suite 1100 Houston, Texas 77056 USA Tel: (281) 498-9202 Fax: (281) 498-0183 Asia Pacific Level 8, 91 William St. Melbourne Victoria 3000 Australia Tel: +61 3 8623 6400 Fax: +61 3 8623 6401 Europe Suite 120, 94 London Road Headington, Oxford Oxfordshire, OX3 9FN United Kingdom Tel: 0800 0322389 Fax: 0800 0322389 2009 Varec, Inc. All Rights Reserved. This document is for information purposes only. Varec, Inc. makes no warranties, express or implied, in this summary. The names of actual companies and products mentioned herein may be the trademarks of their respective owners. Document Code: PRO061GVAE0609