KEY OPERATOR. Study guide TRAINING SERIES ANDERSEN PRODUCTS, LTD. Key Operator Training Kit The power of knowledge. the future of gas sterilisation

Similar documents
KEY OPERATOR. Study guide TRAINING SERIES ANDERSEN PRODUCTS, LTD. Key Operator Training Kit. The power of knowledge. the future of gas sterilisation

KEY OPERATOR STUDY GUIDE

When you successfully complete the test, you will receive a certificate and a registered key ring. We look forward to hearing from you.

KEY OPERATOR STUDY GUIDE

Series 3 + Thank you for using the EOGas 3 sterilization system.

Key Operator Test Study Guide

Best Practice Guidelines For Cleaning, Disinfection and Sterilization of Critical and Semi-critical Medical Devices

Cleaning & Sterilization

المملكة العربية السعودية وزارة الصحة اإلدارة العامة لمكافحة عدوى المنشئات الصحية

Reusable Laryngoscope Blades and Handles

Instruction Manual for FORMALDEHYDE GAS DETECTOR MODEL FP-30/FP-40

CLEANING AND HANDLING OF WRIGHT INSTRUMENTS

Enteral Pump Instructions for Use To Assemble When the low

2015 Myco Industries, Inc Fax:

Operating Manual "Mark II" Solid-State Digital Automatic Controlled Sterilizers

2364 Leicester Road, P.O. Box 175, Leicester, NY Phone (585) Fax (585)

DEPARTMENTAL SAFETY ISSUES - SAFETY TECHNOLOGIST / INFECTION CONTROL PRACTITIONER

STERITITE INSTRUCTIONS FOR USE

Attendance Sheet. (List each model reviewed during this session) Print Name Signature Title. Print Name Signature Title.

INFRARED ZONE HEATING SYSTEM

Soiled garments reflect less radiant heat. Materials saturated with hydrocarbons will absorb not deflect radiant heat from a fire.

INFRARED ZONE HEATING SYSTEM


INFRARED QUARTZ HEATER

FLASH PAK STERILIZATION CONTAINER SYSTEM

Accessories. Maybachstraße. Symmetry Fax: Revised 10/15

INFRARED QUARTZ HEATER

GENANO AIR PURIFICATION TECHNOLOGY

ON TRACK Reprocessing In-service / Competency for CF/PCF/GIF Endoscopes (EVIS, EXERA, EXERA II)

INFRARED ZONE HEATING SYSTEM

PUREPOWER SERIES CENTRAL VACUUM POWER UNITS PP500, PP600 & PP650

IMPORTANT SAFEGUARDS Danger! Danger of burns!! Important!

PICNet CONFERENCE 2013

Instructions for Use Spinal Punches IFU

Chapter 3: Emergency Planning for Laboratories

Recipe Booklet Reverse Side. Pure Indulgence Ice Cream-Frozen Yogurt & Sorbet Maker CIM-60PC INSTRUCTION BOOKLET

PERFORM Operating Document

INSTRUCTIONS FOR CLEANING AND STERILIZATION OF ALL B.BRAUN AESCULAP HAND HELD SURGICAL INSTRUMENTS AND POWER PRODUCTS (UNITED KINGDOM REQUIREMENTS)

Operator s Manual. Model G17-EU (International) Disinfection Soak Station for Hysteroscopes, Cystoscopes and ENT scopes

Dehumidifier Owner s Manual Read and save these instructions before use

Air Purification System. Instruction Book CLI-AP20

ELECTRIC FLAT PANEL FIREPLACE HEATER

Steril Air mobil. Owner s Manual. GENTRA Rıhtım cd. Yuva sk. No: ¾ Beyoğlu İstanbul Turkey Tel : Fax:

Rapid Heat Sterilizers with 6, 8, and 12 Minute Sterilization Cycle Times

V. Mueller. V. Mueller Reusable Devices: Cleaning and Sterilization Guide USA. Rx Only

CRISTAL Built-in Dish Sterilizer Instruction Manual

CLASSIC PLUS INFRARED ZONE HEATER

New Power Vented Rheem FVIR Tanks

_formatted. Number: Passing Score: 800 Time Limit: 120 min File Version: 1.0

Portable Air-conditioner

GV 8 quart Model BP BATTERY POWERED BACKPACK VACUUM

TBR 40 1 GD Blood Refrigerator Instruction Manual. for BLOOD STORAGE REFRIGERATORS MODEL TBR 40 1 GD. (40 x 500ml Blood Bag Capacity)

DC200 Digital Dispenser Operating Manual

INSTALLATION INSTRUCTIONS. WOOD BLINDS 1-3/8, 2 and 2-3/8 SLAT SIZES. COMPOSITE FAUX WOOD BLINDS 2 and 2-1/2 SLAT SIZES

Safety In Chemistry. Identified Risks and Hazards

BEFORE OPERATING, READ ALL INSTRUCTIONS IN THIS MANUAL CAREFULLY.

FIREPLACE HEATER FOR THE FOLLOWING MODELS: EE-8075W EE-8075O EE-8075R

ACME DIAGNOSTICS STANDARD OPERATING PROCEDURE

Dr. Infrared Heater Elite Series

VANTAGE. Installation Manual. Release Date: April 16, 2003 Publication Number: INS Revision Date: January 22, 2015 Revision: E

IMPORTANT SAFETY REMINDERS

CER-1 & CER-2 Installation & Testing Instructions

Homeowner s Installation Instructions & Operating Manual

Up to 60 Pint Commercial Grade DEHUMIDIFIER

Steritech Wetherill Park Pollution Incident Response Management Plan (PIRMP) Steritech Pty Ltd. Pollution Incident Response Management Plan (PIRMP)

SKLAR COATED SURGICAL INSTRUMENTS RECOMMENDED CARE & CLEANING INSTRUCTIONS

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference.

Model CWA200 Owner s Manual

ELECTRIC FLAT PANEL FIREPLACE HEATER. Model# : BG-36B BG-45B BG-50B BG-60B BG-72B BG-100B OWNER S MANUAL

EFX 600. aquamanta. Instruction Manual. 4year guarantee. the experts in aquatic technology. >600 Litres

University of California, Davis Laboratory Self-Inspection Checklist

Dovre 250 Cast Iron Gas Stove

Steam Sterilization and Sterility Assurance in Health Care Facilities ANSI/AAMI ST79. Suzanne Latta, CSPDT. Education Materials Coordinator

OWNER S MANUAL. Portable Air Conditioner. Product defect? Not working properly? DO NOT return this product to the store where you purchased it.

MD-MINI Dry Bath. Instruction Manual

SeedVac TM REF 90091

IMPORTANT INSTRUCTIONS OPERATING MANUAL

SBS Design Considerations for Autoclave Sterilization

Quartzone. Infrared Quartz Tube & Metal Sheathed Electric Heaters. Owner s Manual. File E COMFORT HEATERS for INDOOR* and OUTDOOR** USE

MODEL # EE-8077W. If you have any questions about the operation of your infrared heater, please contact Crane Customer Care.

DIGITAL QUARTZ INFRARED HEATER. Model No.: SPP1500SBH

Integra Salto Talaris and Integra XT Non-Sterile Device Reprocessing. Instructions for Use. 4. Manual Cleaning Instructions

Sterilization pouches. Instructions for Use

USER MANUAL myvacbot SN500 Robot Vacuum

WATER KETTLE RHKT-15001(white) RHKT-15002(black) Instruction Manual

EVAPORATIVE AIR COOLER SERVICE MANUAL

USER MANUAL HD SERIES. WARNING Read the instructions before using the machine. EN (Original Instruction) / 1704 HD5.

User Manual. 110 Cup (55 Cup Raw) Gas Rice Cooker. Model: 177GRCLP, 177GRCNAT 12/2018. Please read and keep these instructions. Indoor use only.

TABLETOP PTC TOWER HEATER

DEHUMIDIFIER USER MANUAL 11 PINT FOR MODEL: 3PAD11 COMFORT...BUILT TO LAST

R32. Installation Manual Split Type Wall Mounted Air Conditioner. This appliance shall be installed in accordance with: REFRIGERANT

When you sterilize an instrument set, you know what the standards are.

Operator s Manual. Model G14TC-3 Disinfection Soak Station for Transesophageal Ultrasound Probes

Mobile Air Conditioner Use and Care Manual. Part Number: 048-GM-48265

Gallery Electric Fireplaces

Operator s Manual. Video Laryngoscope. ( Instructions for use ) Doc no: Revision 1.1 8th January 2013

OWNER S MANUAL. FLAT PANEL FIREPLACE HEATER Model Number: Serena (EF202A) WARNING CAUTION

MIT Emergency Response Guide

DEHUMIDIFIER OWNER S MANUAL. Read this manual carefully before operating the appliance and retain it for future reference.

ULTRA LOW TEMPERATURE FREEZER. User Manual

Transcription:

KEY OPERATOR TRAINING SERIES ANDERSEN PRODUCTS, LTD Study guide Key Operator Training Kit The power of knowledge the future of gas sterilisation

Thank you for using the Anprolene sterilisation system. APPLIES TO MODELS: AN74i, AN74ix, AN74j and AN2000 The active ingredient in the Anprolene system is ethylene oxide (EtO). EtO is a powerful anti-microbial agent; it needs to be handled with care. To help ensure that your steriliser is operated safely, all personnel who operate or maintain the equipment should be properly trained. The Andersen Anprolene Key Operator Certification Program is available free of charge for the lifetime of your steriliser. We recommend that all operators at your facility are trained before they use the steriliser for the first time. Once you have reviewed the information contained in this study guide, please fill in the Answer Booklet and send it over to us by fax (0203 163 0791) or e-mail (fstoker@anderseneurope.com). Then, please call Andersen Customer Service at 01255 428328, whenever it is convenient for you, to complete your Key Operator test over the phone (this will take around 20 minutes). Shortly after successfully completing your test, you will receive a registered training certificate. We look forward to hearing from you! Certification Program Outline Preparing for Sterilisation...Pg 2 The Sterilisation Cycle...Pg 3 Unloading the Steriliser and Determining Sterility...Pg 6 Safety Precautions...Pg 7 Study Guide Review & Scheduling a Test...Pg 9 Overview of the Anprolene Sterilisation System. 1 The Anprolene system is a room temperature Ethylene Oxide (EtO) steriliser. This sterilisation system must be installed and operated in an environment that maintains a temperature of no less than 20 C to be effective. 2 The usual Anprolene cycle is 12 hours, plus an automatic two hour bag ventilation (purge) cycle to remove excess gas and prevent the operator from being exposed to the gas. 3 When sterilising tubing 3 feet or longer, or a full load of gas absorbent items, it may be necessary to use two gas ampoules and increase the cycle time to 24 hours. This extra dosage and time ensures proper gas contact inside of the long lumens. Some gas absorbent items require additional aeration to prevent chemical burns that can be caused by premature contact with living tissue. 4 Maintaining a relative humidity above 35% is critical to the success of the Anprolene cycle. The AN1071 Humidichip and AN1072 Humiditube ensure that humidity requirements for Anprolene sterilisation are maintained in the sterilisation bag. 5 The AN87 Dosimeter provides an immediate indication at the end of a cycle that adequate time, temperature, and EtO concentration for sterilisation have been met.

H G F E Anprolene Supplies & Parts Index I J K L B A D C A: Power Switch B: Cabinet Digital Display C: Program Buttons D: Steriliser Lock and Key E: Sturdy Stainless Steel Cabinet F: Power Cord Socket (Power Supply: 115/230V) G: Cooling Fan Guard with Removable Filter H: Abator Connector Slot I: Quick Connector Slot for Exhaust Hose J: Independent Purge and Vent Pumps K: Wrapped Sterilisation Load L: Purge Probe Anprolene Sterilisation Cabinet M: Gas Sterilisation Bag N: EtO Ampoule in Release Bag O: Humidichip and Tube P: Black Velcro Strap with Buckle Q: Quick Release Connector N K M L O Loaded Sterilisation Bag P Q Anprolene Sterilisation Accessories AN71/73 & 79 Gas Refill Kits contain replacement gas ampoules and liner bags in a convenient storage/dispenser box. Two different bag/ampoule combinations to match your sterilisation needs AN85 Exposure Indicator Strips change color to provide immediate assurance of gas exposure at the end of the sterilisation cycle. They include convenient self-stick backing that adheres to conventional paper or cloth wrapping. AN2203 EZ Test Biological Indicators reliably verify that sufficient concentration of EtO killed one million B. atrophaeus spores, the spore most resistant to EtO gas. Biological indicators are the best method to ensure sterility after a cycle. AN87 Dosimeter Chemical Integrators present visual assurance that proper time, temperature, and EtO concentration were reached during the sterilisation cycle. Anprolene, Dosimeter, Humidichip, and EOGas are trademarks of H. W. Andersen Products, Ltd. AN1071 Humidichip & AN1072 Humiditube These pre-moistened chips placed inside the tube ensure that relative humidity requirements are met during the sterilisation cycle. AN91,92,& 93 AirScan EtO Monitoring Badges are single use badges that measure personnel exposure to airborne concentrations of EtO. Immediate results are provided with no extra instruments or analysis needed. 1

KEY OPERATOR STUDY GUIDE 1 Preparing for Sterilisation A. Environmental Considerations 35ºC 20ºC 1 Temperature - Gas Storage Temperature: Store your Anprolene gas refill kits in a cool, secure area. We recommend storage below 30 C. - Operational Temperature: The steriliser must be used in an area where the temperature is not less than 20 C or more than 35 C. EtO FACTS: At sea level, ethylene oxide is a liquid below 11 C. Above 11 C, EtO begins to boil and converts into a gas. EtO does not become an effective sterilant until it is 20 C. Make sure that the room where your Anprolene steriliser is installed remains above 20 C during the entire sterilisation cycle. This is especially important during the winter months! 35% 2 Humidity Humidity is very important to the Anprolene process. Relative Humidity (RH) must be at least 35% in the room where item preparation and sterilisation take place. Spores that might be on the instruments may become desiccated and more resistant to EtO if the RH is below 35%. The simplest way to humidify items prior to sterilisation is to wash them. Items that cannot be washed (such as laptops, cameras, and delicate electronics) should be humidified by placing the wrapped or pouched items in a plastic bag with an Andersen Humidichip for four hours in a warm area (above 20 C). If room RH is lower than 35% during the sterilisation cycle, a Humidichip is placed into the sterilisation bag to maintain proper humidity. B. Four Basic Steps of Pre-cleaning Follow manufacturer's instructions for cleaning and preparing reusable devices for EtO sterilisation whenever possible. In the absence of manufacturer's instructions, these general steps should be followed: 1 Disassemble Items containing removable parts such as syringes must be taken apart before washing, drying, and wrapping them to allow the EtO an unobstructed path around all parts. WARNING: Instruments which contain batteries must be taken apart and the batteries removed and wrapped separately to protect against a spark occurring and igniting the ethylene oxide gas. 2 Wash Presoak the items, if appropriate. Items must be washed surgically clean prior to sterilisation using detergent and water. 2

KEY OPERATOR STUDY GUIDE 3 Dry Three accepted ways to dry any item prior to sterilisation with Anprolene are: 1. Towel drying 2. Drain drying (air drying) 3. Compressed air for tubing and long lumens. WARNING: Heat or hot air should not be used to dry an item prior to sterilising it with Anprolene because it may dehydrate or desiccate bacteria spores making them more resistant to the ethylene oxide gas. WARNING: Any water left on items may react with ethylene oxide. Items must be thoroughly dried. 4 Wrap The following types of wrapping material are recommended for use with Anprolene: 1. Heat sealed packaging such as Seal and Peel or Tyvek / Plastic. 2. Self seal pouches or peel packs made of paper and plastic film. 3. Cloth, paper, or Central Supply Room (CSR) wrap. Always follow manufacturer's use and shelf-life guidelines for all packaging. AN86 HINT: Exposure indicators such as the Andersen AN85 or AN86 are used to seal or label items. Indicators will change color in the presence of EtO, helping to later identify items that have been sterilised. Exposure indicators DO NOT indicate sterility. 2 The Sterilisation Cycle A. Loading the Liner Bag and Steriliser 1 Place prepared items in a new sterilisation liner bag. WARNING: Do not reuse sterilisation liner bags. Even a tiny pinhole in a liner bag can allow gas to escape and cause cycle failure! WARNING: Liquids, powders, food, and drugs should not be sterilised in ethylene oxide because it may change their chemical composition in unpredictable ways. If you have any questions about whether an item may be sterilised using EtO, please call Andersen Customer Service. 3 3

74ix AN7916 74ix KEY OPERATOR STUDY GUIDE 2 Insert appropriate controls such as a chemical integrator (Dosimeter) or a biological indicator (EZ Test) into the least accessible part of the sterilisation liner bag. If room relative humidity is below 35%, add a Humidichip to a Humiditube and place into the sterilisation liner bag. AN 79 ANPROLENE 3 Unroll the gas release bag containing the gas ampoule and, without opening it, gently move the ampoule to the center of the gas release bag. Place it on top of items in the sterilisation liner bag where it will be easy to break. Never open the gas release bag. This prevents liquid from coming into contact with the skin, and gas from escaping too quickly to achieve sterilisation. WARNING: Reasons why the gas release bag containing the ampoule should never be opened: - To prevent the liquid ethylene oxide from coming in contact with the user or the items to be sterilised. - To prevent the gas from escaping too quickly to achieve sterilisation. 4 Insert the purge probe into the sterilisation liner bag with the bobbin and quick release fitting at the open end. Place the black Velcro strap around the sterilisation liner bag and the bobbin of the purge probe, and pull it snug through its loop to completely close the sterilisation liner bag. The strap must tightly secure the sterilisation liner bag around the purge probe bobbin in order to keep gas from escaping. Bobbin Quick Release Connector 5 Connect the quick release connector to the purge hose if it is not already connected. HINT: The sterilisation liner bag may be loaded and closed away from the steriliser cabinet and connected to the purge hose once you are ready to start a cycle. B. Starting the Cycle AN74 I ANPROLENE STERILIZER START 1 Make sure the steriliser is connected to power. Press the power switch on the front panel. Wait to see the "(model #) ANPROLENE STERILISER" and the "START" message to appear on the cabinet display. 2 Push the button to the right of START. 3 Wait for the SELF TEST and number of elapsed PUMP HOURS to appear. 4

KEY OPERATOR STUDY GUIDE SELF TEST OK 0 PUMP HOURS 4 Press the button next to the PURGE message on the right of the display and wait for 1 minute 30 seconds until the display reads '00:00:00'. The sterilisation liner bag should vacuum down as excess air is removed. 5 When the display indicates BREAK AMPOULE, carefully, so as not to puncture the sterilisation liner bag, grasp the ampoule through the sterilisation liner bag and activate it by snapping off the top. WARNING: Use only genuine Anprolene gas products in your steriliser. Use of other gas sources may result in operator injury and/or non-sterile loads. C. Selecting Cycle Length 1 Once the ampoule is broken, close the door. 2 Lock the steriliser and remove the key. 74ix 3 SELECT CYCLE LENGTH. (Right button = 12 Hour, Left button = 24 Hour). The cycle length cannot be selected until the door is closed. 74ix WARNING: The usual Anprolene sterilisation cycle is 12 hours, plus a 2-hour purge cycle. When sterilising tubing 3 feet or longer (eg GI endoscopes) the 24 hour cycle should be selected. A full load of gas absorbent items (eg rubber tubing, bandages, swabs) may require two gas ampoules to ensure the dosimeter reaches the triangular mark. 4 If a cycle length is not selected within 5 seconds after closing the door, an alarm will sound to remind you to choose one. 5 After the cycle length is selected, the steriliser display will countdown the time remaining until the sterilisation cycle is complete. WARNING: Never interrupt a cycle once the gas ampoule has been activated. An alarm will sound if the door is opened during the cycle. 6 Log sterilisation data if required. D. Additional Aeration 74ix Throughout the entire cycle, the ventilation system is always running to prevent EtO gas from entering the room. Once the 2 hour purge cycle is complete, the steriliser will continue to ventilate and purge the liner bag. A count-up timer will begin on the steriliser 5

KEY OPERATOR STUDY GUIDE display to keep track of additional aeration time, and the steriliser will reset only after the door is opened and the exit button is pressed. The temperature in the room should continue to remain at least 20 C during the aeration period. Some gas absorbent items require additional aeration after the regular sterilisation/purge cycle and before they can be removed and used. This extra aeration prevents chemical burns to living tissue that can be caused by residual EtO absorbed during the sterilisation cycle. AAMI guidelines state that product aeration should take place inside the steriliser cabinet. E. Aeration Guidelines Some large, gas absorbing items (especially implants, long lengths of tubing, and devices that will contact blood or living tissue) require additional aeration time: 1 If the item's manufacturer provides guidelines on aeration required after EtO sterilisation, follow those guidelines. 2 Two types of materials that do not require additional aeration are metal and glass. Items made of these materials do not absorb EtO. 74ix 3 3 If the item's manufacturer does not provide guidelines on aeration required after EtO sterilisation, the item should remain in the Anprolene steriliser or placed outside the cabinet in a well ventilated room to aerate for an additional 24 hours after the sterilisation and purge cycles are complete. Unloading the Steriliser and Determining Sterility A. Unloading The Liner Bag: 1 Remove the sterilised items only after the sterilisation cycle, 2-hour purge cycle, and any additional aeration have been completed and the display indicates "UNLOAD STERILISER". HINT: To unload the sterilisation liner bag away from the steriliser, simply detach the purge hose from the bag using the quick release connector. 2 Remove the sterilised items and examine the Dosimeter. Make sure the blue line has progressed up to or beyond the triangular mark. 3 Discard the sterilisation bag, Humidichip, and used ampoule with ordinary trash. Incubate Biological Indicator if using one. Retain Humiditube to use again. 4 Press EXIT to end the cycle and return the steriliser to the standby state. Switch the power button to off. 6

B KEY OPERATOR STUDY GUIDE WARNING: Never remove items before the full sterilisation and 2-hour purge cycles have completed. The purge cycle is designed to aerate most products sufficiently to avoid operator exposure to EtO by meeting the OSHA short-term exposure level (STEL) of 5.0 ppm over 15 mins. B. Important Notes About Indicators: 1 Biological Indicators (BI's) such as the AN 2203 EZ Test use live spores and are the best confirmation of the success or failure of a sterilisation cycle. Always follow manufacturer's recommendations when using BI's. 2 Chemical Exposure INTEGRATORS such as the AN87 Dosimeter provide immediate visual confirmation that time, temperature, and EtO concentration were sufficient for sterilisation to occur. 3 Chemical Exposure INDICATORS such as the AN85 or AN86 do not prove sterilisation. They only change color to show that the items have been exposed to ethylene oxide. 4 Please refer to manufacturer's instructions when using sterility or exposure indicators. Safety Precautions A. Ethylene Oxide Safety 1 Do not allow open flame or sparks near the steriliser during the sterilisation cycle. Ethylene oxide gas is highly flammable in concentrations above 3.0% (30,000 ppm). The Sterilization Cycle 2 Never interrupt a cycle in progress. 3 Sterilisation liner bags should never be reused because they may have a puncture or tear. 4 The 12 and 24-hour sterilisation cycles both end with a 2-hour purge cycle, which flushes fresh air around the items in the sterilisation load. MONITORING SYSTEM A 5 Personnel exposure to ethylene oxide can be monitored by using personal exposure badges such as the Andersen AN93 AirScan Badges. The AN93 AirScan Kit has both STEL (15 min.) and TWA (8 hour) badges. EtO exposure levels should be checked upon installation of the steriliser. We recommend that exposure testing be performed on an annual basis or whenever a steriliser is relocated. OSHA guidelines for personal monitoring can be found at www.cdc.gov/niosh/programs/ppt. 6 If an ampoule is accidentally activated outside of the bag, immediately place it in the sterilisation cabinet and start a cycle. 7

KEY OPERATOR STUDY GUIDE 7 Always store Anprolene gas ampoules and refill kits in a secure cabinet that is kept cool (30ºC or below) and out of direct sunlight. B. Reasons for Locking the Anprolene Steriliser: 74ix - To protect the contents from spark or flame. - To protect the liner bag from puncture. - To ensure the Anprolene steriliser exhausts the ethylene oxide through the ventilation system to the outside. Note: No other container or steriliser can be used with Anprolene sterilising gas. C. Malfunctions and Power Failures LOW TEMP WARNING PURGE PUMP FAILURE VENT PUMP FAILURE Low Temperature Warning If at any time during the cycle the temperature around the steriliser drops below 20 C, a low temperature warning will be displayed. This warning may indicate that the cycle was unsuccessful due to inadequate temperature. Check your sterility indicators to confirm the success of the cycle. Purge Pump Failure In the event of a purge pump failure, the vent pump will continue to ventilate the interior of the cabinet, exhausting gas as it diffuses through the sterilisation liner bag. A PURGE PUMP FAILURE error message will be displayed, and the steriliser will add 24 hours of aeration before the display indicates that you may remove your products. If this happens, please call Customer Service for assistance, 01255 428328. Vent Pump Failure In the event of a VENT PUMP FAILURE, the cycle will be aborted, and the purge pump will evacuate the liner bag of any remaining gas. If this happens, please call Customer Service. Power Outage If a power outage occurs during any part of the cycle, the steriliser is equipped with a battery back up to the circuit board that will keep track of elapsed cycle time. When power is restored, the cycle will continue. Do not open the door of the steriliser until power is restored and the vent/purge systems have removed any residual gas from the liner bag. When the cycle is complete the display will indicate UNLOAD STERILISER. HINT: In the case of any steriliser malfunction or power failure, you can determine whether sterilisation was achieved by examining the sterility indicators (biological indicator, and Dosimeter) included in the load. 8

KEY OPERATOR STUDY GUIDE D. Emergency Procedures 1 If liquid EtO comes into contact with a part of the body, you must wash with water thoroughly for at least 15 minutes. Consult the Material Safety Data Sheet (MSDS) for further information. 2 The Material Safety Data Sheet (MSDS) for EtO Gas should be readily available at your facility. Do you know where to find your MSDS? - Operator's Manual - List of physical and chemical hazards is provided with each Anprolene refill kit. In case of emergency, please contact: Chem-Tel on 001 813 248 0585 Chem-Tel contract number MIS 0000425 5 Study Guide Review Here is what you should know after reading this study guide: The minimum temperature needed in the room for the entire sterilisation cycle The length (in time) of the standard cycle Why the ventilation system is running during the entire cycle Why the sterilization liner bag is purged The required relative humidity in the room where the items are prepared How to prepare items for sterilisation The types of indicators that should be used in the Anprolene system Ethylene oxide safety and precautions Basic operation of your Anprolene steriliser from start to finish When you feel comfortable with answers to these subjects, please fill in the Answer Booklet and send it over to us by fax (0203 163 0791) or e-mail (fstoker@anderseneurope.com). Then, please call Andersen Customer Service at 01255 428328, whenever it is convenient for you, to complete your Key Operator test over the phone (this will take around 20 minutes). Operator training records should be maintained at your facility. Key Operator Tests will also be kept on file at Andersen Products. If you would like to have an Andersen representative come to your facility for in person training, please contact Andersen Products for a quote on this custom service. Many thanks for using the Andersen Anprolene steriliser. Please do not hesitate to call us if you have any questions in the future. Andersen Customer Services 01255 428328 www.anderseneurope.com Nothing in this guide should be taken to amend or supercede the manufacturer s reprocessing instructions. 9

the future of gas sterilisation www.anderseneurope.com H.W. Andersen Products Ltd Unit 808, Oakwood Business Park Fowler Road Clacton-On-Sea, CO15 4AA United Kingdom 2013 ANDERSEN PRODUCTS, LTD. ALL RIGHTS RESERVED. AirScan is a trademark of AirScan Environmental Technologies, Inc. Anprolene,, Humidichip, Seal and Peel, are trademarks of H. W. Andersen Products, Ltd. Ref: Anpro Study Guide 201609a