Motor Kit for SW Shutter. Instruction Manual. Motor Kit for SW Shutter. Models: FA2685. Munters Corporation, November 2013 QM1017r6

Similar documents
BA2702-P Linear Actuator

AX51 with Munters Drive

BA4000 Series Curtain Machine

RC Series Discharge Cones

Flatsided Discharge Cone Models: 54GC & 54GCX

BI28SP Ceiling Inlet. Instruction Manual. BI28SP Ceiling Inlet. Bi-Flow, Spring Actuated. Models: BI28SP BI28SP-01

FM Munters Drive. Instruction Manual. Munters Drive * Motor Replacement Kit. Motor Replacement Kit for AX and VX Fans

MD Munters Drive. Instruction Manual. Munters Drive * Motor and Controller Replacement Kit. Motor & Controller Replacement kit for AX and VX Fans

IA Inlet Actuator. Instruction Manual. IA Inlet Actuator Models: IA0090 IA0090P. Munters Corporation, March 2017 QM1235r1

VX51 and VX55 with Munters Drive 51 and 55 Exhaust Fan

AIR HEATING PRODUCTS

Manual for use and maintenance. + CE Declaration of conformity. TU600 - TU800 Chimney fan. Ag/MIT/UmGB /14 rev 1.0

MFS. Manual for use and maintenance. + CE Declaration of conformity MFS. Air circulation fan. Models: MFS36 - MFS52. Ag/MIT/UmGB /13 rev1.

WDP. Installation manual WDP. Gutter system. Ag/MIT/UmEN /14 rev 1.0

M I S T E L I M I N AT I O N. Mist elimination in Flue Gas Desulphurization. The buck stops here.

STT 3000 Series STT250 /150 Surge Protection Device Specifications

Positive Pressure Filtered Swine Facilities

FF-SR Series. FF-SR25933 Two-hand Safety Control Module FF-SR25933

High performing temporary space heaters

Evaporative Humidifier/Cooler FA6 for AHU s Technical manual FA6. HC/MMA/TGB /10 pdf SOS ReklamStudio

DESCRIPTION FEATURES WARNINGS APPLICATIONS

14" - 24" CLASSIC Direct Drive Fans

Beckhoff short profile

JAZ. Operator s Manual. Diesel/Kerosene Air Heaters JAZ 42 JAZ 80 JAZ 80 W JAZ 125 JAZ 160

Press Release. Short profile Beckhoff. Short profile February 2009 Page 1 of 6

High vacuum guide FOR PRE-SEPARATORS AND CYCLONES

Type 2 safety light curtain Type 2 according to the IEC/EN parts 1 and 2 Compact profile: 31 x 32 mm 30 mm resolution for hand detection Wide r

Contents. Introduction. Introduction About This Report 1. Sustainability & Strategy. Social Respect for Human Rights and Diversity 15

FieldLink Cable solutions for Automation & Drives

Leading manufacturer of high-end ball valves and pneumatic actuators. Over 60 years experience with industrial applications

36 & 48 E-Z Cone Fan. Installation & Operator s Instruction Manual (Direct Drive)

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

TURBO Fiberglass Cone Fan and Grill Fan 48'' Belt Drive. Installation & Operator s Instruction Manual

Accuracy counts! Sensors with analog output

92 RAILWAY ST. SEAFORTH, ONTARIO CANADA, N0K 1W0 TEL: ABSOLUTE AIR INSTALLATION MANUAL

International standards used locally worldwide ISO/TC 67

Waterpik Water Flosser Model WF-02

Product catalogue. Solutions for the Dairy segment

OneWireless Gauge Reader WGR400 Series Specifications 34-XY July 2009

Installation Instructions

48 Vanguard Belt Drive Fans Installation and Operators Instruction Manual

Seals for rotary equipment. Superdeal and Goodeal TM

Shredders from Metso. Lindemann Eta Shred

Crushers from Metso Recycling. Metso EtaCrush

48 Vanguard Belt Drive Fans Installation and Operators Instruction Manual

Annunciator Relay MR 11 and MRE 11 MR 21 and MRE 21. Automation Equipment. Power Station Control Systems. Control Room Technology

WAIMEA. Waimea Showerspa Model #1034 Owner's Manual

BFD Light Curtains The new choice for cutting edge safety for industrial doors

BREEZE FAN. Breeze Fan. Manual for use and maintenance. Air circulation fan. + CE Declaration of conformity. Ag/MIT/UmGB /17 Rev 1.

PTG, SWT Series. Heat Recovery Systems

HIGH PRESSURE DOUBLE CASE PUMPS

Advantages of automatic boiler bottom blowdown

Security Trade Control by a Japanese company. 20 July, 2017 Shozo HIRATA NEC Corporation

USER S OPERATING AND INSTRUCTION MANUAL

... Desiccant Cartridges Conventional and Oil Separator Cartridges (OSC) ... products derived from proven Knorr-Bremse Technology. Product Information

Oahu Showerspa Model #1035 Owner's Manual

PRODUCT INFORMATION. GM901 Carbon Monoxide Gas Analyzers CO MEASUREMENT FOR EMISSION MONITORING AND PROCESS CONTROL. In-situ Gas Analyzers

A WMIA Partner of the Year Winner S-Series Enclosureless Dust Collector

THE GUSTO CEILING FAN INSTALLATION INSTRUCTIONS

VICOTEC450 EXTRACTIVE VISIBILITY MEASURING DEVICES EXTRACTIVE VISIBILITY MEASUREMENT FOR INCREASED SAFETY IN TUNNELS

Detect. React. Benefit. Increase the availability of your plants with SIMATIC Notifier!

COMBIFAB F Fan The flexible fan for dust extraction systems in all industries

E + M III. Suitable for interfaces. up to CATEGORY 4 per EN E197638

MVX 2000 Multivariable Pressure Transducer. Specifications 34-SM March Introduction. Proven Sensor Technology. Flow Computer Benefits

Rain Forest Quick Guide

PRODUCT INFORMATION HISIC450 OVERHEIGHT DETECTORS RELIABLE OVERHEIGHT DETECTION OF VEHICLES. Traffic sensors

Spiral dewaterer. Optimal for dewatering of solids in water treatment systems

RIO. Rio ShowerSpa Model #1049B-BN Owner s Manual

IWAKI HI-CERA PUMPS V

ELSTON 52 CEILING FAN

Installation, Operation and Maintenance Instructions

Waterpik Water Flosser Model WF-06

Future development of the furniture industry A look at the next 3-5 years

THE HYTORC WASHER SYSTEM

Compressor Kit for ToughTek F340e Fireproofing Pump

POWER CUT Hedge Trimmer 46 Model No. 101HT450

DPM-G DPM-CR DPM-W DPM-B INDOOR DOME PENDANT MOUNT INSTALLATION MANUAL

Owner's Manual. Voltage Converter. Reverse. 110V to 220V STEP UP. For International Power Connectivity Converts U.S. 110V to Foreign 220V

NIAGARA. Niagara ShowerSpa Model #1048B-BN Owner s Manual

FUTURE AIR SOLUTIONS OIL FREE SCROLL COMPRESSORS

POWER SWEEP N VAC 1800W Model No. 101BV1800

AutoM Click to go to the page. AutoM Auto Shaker Filter

User s Manual and Operating Instructions

Air Storm Fans. Air Storm 18 Fiberglass Fan Installation and Operation Manual

User s Manual and Operating Instructions

Manusa Automatic. Doors. Safety beyond the Standard. EN16005 Power operated pedestrian doorsets. Safety in use. Requirements and test methods.

MUNTERS SERVICE GUIDE. Service, maintenance & upgrades. Your Trusted Global Service Partner

TURBO Hooded Fans. Installation & Operator s Manual (14, 18, & 24 Direct Drive)

STANDARD T6 (200 C) SENSOR CABLE RANGE

Fellowes 4200SC/ 4200CC/C-420HS Paper Shredder

PRODUCT INFORMATION. SureSense THE SURE WAY TO DETECT ANY OBJECT. Photoelectric Sensors

BUILD the clinic you ve always imagined.

SOUP COOKER/WARMER 120V, 240V MODEL 6423 INSTRUCTIONS. Installation Operation Maintenance

Waterpik Water Flosser Model WP-450/462/ 463/465/470

Window Accessories Whitmatic

Waimea ShowerSpa MODEL #1034

Fire-Resistant. Automatic Doors

ML Plus System. Energy efficient climate control. Desiccant dehumidification system with integrated pre- and post treatment

Waterpik Water Flosser Model WP-150/152

WORLDS MOST ADVANCED ANTI-PRY DESIGN 2018 PRODUCT CATALOGUE

Transcription:

Instruction Manual Motor Kit for SW Shutter Motor Kit for SW Shutter Models: FA2685 Munters Corporation, November 201 QM1017r6 1

Munters Drive Motor Kit for SW Shutters Manual for use and Maintenance Thank You: Thank you for purchasing a Motor Kit for SW Shutter. Munters equipment is designed to be the highest performing, highest quality equipment you can buy. With the proper installation and maintenance it will provide many years of service. Please Note: To achieve maximum performance and insure long life from your Munters product it is essential that it be installed and maintained properly. Please read all instructions carefully before beginning installation. Warranty: For Warranty claims information see the Warranty Claims and Return Policy form QM1021 available from the Munters Corporation office at 1-800-227-276 or by e-mail at aghort.info@munters.com. Conditions and Limitations: Products and Systems involved in a warranty claim under the Warranty Claims and Return Policy shall have been properly installed, maintained and operated under competent supervision, according to the instructions provided by Munters Corporation. Malfunction or failure resulting from misuse, abuse, negligence, alteration, accident or lack of proper installation or maintenance shall not be considered a defect under the Warranty. 2 QM1017r6 Munters Corporation, November 201

Index Chapters Page 1. Unpacking the Equipment 4 1.1 Parts List 1.2 Dimensions 2. Installation Instructions 5 2.1 Install 2.2 Install for Double Panel 7 2. Electrical Wiring 9 Munters Corporation, November 201 QM1017r6

Unpacking the Equipment 1. 1.1 Parts List Each FA2685 Motor Kit includes: 1 - Motor (FA265), 120/240 VAC, 60Hz 1 - Crank Arm w/ Bushing and Screw 1 - Hardware package (HP1207) HP1207 Hardware package [A]...1 - Small Motor Mounting Plate [B]...1 - Large Motor Mounting Plate [C]...2 - Return Springs [D]...8 - S -Hooks, ZP [E]...2 - Flanged Bushings, Nylon [F]...1 - Chain, 100 L., Twisted Link, ZP [G]... - #8 x 4 Tapping Screws, ZP [H]...4 - #10-24 x 1 4 Machine Screws, ZP [J]...2 - #10-24 x 1 Machine Screws, ZP [K]...4 - #10-24 Hex Nuts, ZP [C] [D] [E] [F] [G] [H] [J] [K] 1.2 Dimensions 6.000" 1.750" 2.625" Front View Side View MOTOR with CRANK ARM 4 QM1017r6 Munters Corporation, November 201

Installation Instructions 2. 2.1 INSTALL If installing a Single Panel Shutter proceed to Step 1. If installing a Double Panel Shutter go to Page 7, Step 9. Step 1 Working from the inlet side of the shutter, drill an 1 8 dia. hole 1 1 4 left of and 16 above bottom edge of shutter frame. See Figure 1. Step 2 Install (1) Bushing [E] on (1) 1 Screw [J] with (1) Nut [K]. Insert this assembly in hole approximately 6 down from top of and secure with (1) Nut [K]. See Figures 2 and. 1 1 4" 16 " Figure 1 #10-24 x Hex Nut [K] #10-24 x 1" Screw [J] Shutter Blade 6" Approximately Hole in Figure 2 Figure Munters Corporation, November 201 QM1017r6 5

Chapter 2 Installation Instructions Step Fold (1) Spring [C] in half and hook end loops on (1) 'S' Hook [D] and pinch hook closed. At center of folded Spring [C] hook several loops of spring on a second 'S' Hook [D] and pinch closed. See Figure 4. Connect hook on one end of Spring Assembly through 1 8" diameter hole in frame and stretch spring to connect other hook over Bushing [E]. See Figure 5. Return Spring Connection Bar Return Spring [C] 'S'-Hook [D] Figure 4 Step 4 Fasten Small Motor Mounting Plate [A] to Motor using (4) 1 4" Screw [H]. See Figure 6. Step 5 Position Mounting Plate on bottom shutter frame with holes 16" below edge and with the left hole in line with. Mark and drill two 1 8" dia. holes in frame. Fasten Mounting Plate with Motor to frame using (2) Tapping Screw [G]. See Figure 7. Motor Small Mounting Plate [A] Figure 5 Figure 6 #10-2 x 1 4" Screw [H] Small Mounting Plate [A] Step 6 Install (1) Bushing [E] on (1) 1" Screw [J] with (1) Nut [K]. Insert this assembly in hole approximatly 7" above motor in and secure with (1) Nut [K]. See Figures 2 and 8. Step 7 Cut a 9" long piece of Chain [F] and connect between Bushing [E] on the and the Crank Arm using (1) 'S' Hook [D] on each end. See Figure 8. Rotate the Crank Arm counterclock wise to the stop screw and adjust the Lead Chain until the Shutter Blades are fully open. 16" 9" Lead Chain [F] 7" Approx. Step 8 Mounting Plate [A] Crank Arm Figure 7 Figure 8 Installation is now complete. Proceed to Electrical Wiring Section. See page 9. 6 QM1017r6 Munters Corporation, November 201

Installation Instructions Chapter 2 2.2 INSTALL for Double Panel Shutter Step 9 Working from the inlet side of the shutter, drill two 1 8" diameter holes 16" above bottom edge of shutter frame and 1 1 4" to the inside of each. See Figure 9. 1 1 4" 1 1 4" 16" 16" Figure 9 Step 10 Install (1) Bushing [E] on (1) 1" Screw [J] with Nut [K]. Insert this assembly in hole approximately 6" down from top of each and secure with (1) Nut [K]. See Figures 10 and 11. #10-24 x 1" Screw [J] #10-24 Hex Nuts [K] Shutter Blade 6" Approx. Hole in Figure 10 Figure 11 Step 11 Hook one end loop of Spring [C] on (1) 'S' Hook [D] and pinch hook closed. Hook other end loop of same Spring [C] on a second 'S' Hook [D] and pinch closed. Connect hook on one end of spring assembly through 1 8" diameter hole in frame and stretch spring to connect other hook over Bushing [E]. Repeat for second Spring [C]. See Figure 12. Return Spring [C] Return Spring [C] Figure 12 Munters Corporation, November 201 QM1017r6 7

Chapter 2 Installation Instructions Step 12 Fasten Large Motor Mounting Plate [B] to Motor using (4) 1 4" Screw [H]. See Figure 1. Step 1 Position Mounting Plate on bottom shutter frame with holes 16" below edge and with the left hole 16" right of left edge of center support. Mark and drill three 1 8" diameter holes in frame. Fasten Mounting Plate with Motor to frame using () Tapping Screw [G]. See Figure 14. Motor #10-24 x ¼" Screw [H] Large Mounting Plate [B] Large Mounting Plate [B] Figure 1 16 " 16 " Figure 14 8 QM1017r6 Munters Corporation, November 201

Installation Instructions Chapter 2 Step 14 Cut a 12" long piece of Chain [F] set aside. Connect remaining Chain [F] to the Flanged Bushing in each using (1) 'S' Hook [D] on each end. This Yoke Chain should create a 'V' with the center approximately 7" above motor. See Figure 15. Step 15 Connect 12" long Chain [F] between the Crank Arm and the center of the Yoke Chain using (1) 'S' Hook [D] on each end. See Figure 15. Rotate the Crank Arm counterclockwise to the stop screw and adjust the Lead Chain until the Shutter Blades are fully open. Step 16 Installation is now complete. Proceed to Electrical Wiring Section. Return Spring [D] Flanged Bushing [E] Yoke Chain [F] 12" Lead Chain [F] 7" Approx. Figure 15 Motor with Mounting Plate 2. Electrical Wiring Munters Corporation, November 201 QM1017r6 9

Motor Kit for SW Shutter is developed and produced by Munters Corporation, Mason, Michigan U.S.A. 1-800-227-276 Munters Europe AB, Isafjordsgatan 1, P.O. Box 1150, SE-164 26 Kista, Sweden. Phone +46 08 626 6 00, Fax +46 8 754 56 66. Munters Corporation 4215 Legion Drive Mason, MI 48854-106 U.S.A. Phone +1 800-227-276, Fax +1 517-676-7078 www.munters.us Australia Munters Pty Limited, Phone +61 2 6025 6422, Brazil Munters Brasil Industria e Comercio Ltda, Phone +55 41 17 5050, Canada/US Munters Corporation Mason, MI Phone +1 517 676 7070, China Munters Air Treatment Equipment (Beijing) Co. Ltd, Phone +86 10 80 481 121, Denmark Munters A/S, Phone +45 9862 11, India Munters India, Phone +91 20 052 2520, Indonesia Munters, Phone +62 818 79 25, Italy Munters Italy S.p.A., Chiusavecchia, Phone +9 018 52 11, Japan Munters K.K., Phone +81 5970 0021, Korea Munters Korea Co. Ltd., Phone +82 2 761 8701, Mexico Munters Mexico, Phone +52 818 262 54 00, Russia Munters AB, Phone +7 812 448 5740, Singapore Munters Pte Ltd., Phone +65 744 6828, South Africa and Sub-Sahara Countries Munters (Pty) Ltd., Phone +27 11 997 2000, Spain Munters Spain S.A., Phone +4 91 640 09 02, Sweden Munters AB, Phone +46 8 626 6 00, Thailand Munters Co. Ltd., Phone +66 2 642 2670, Turkey Munters Form Endüstri Sistemleri A.Ş, Phone +90 22 21 18, USA Munters Corporation Mason, MI Phone +1 517 676 7070, Vietnam Munters Vietnam, Phone +84 8 825 688, Export & Other countries Munters Italy S.p.A., Chiusavecchia Phone +9 018 52 11 10 QM1017r6 Munters Corporation, November 201