and SHUTTERS Made to Work. Built to Last.

Similar documents
Chore-Time Fan Guide For Tunnel and Other Applications

48 Vanguard Belt Drive Fans Installation and Operators Instruction Manual

48 Vanguard Belt Drive Fans Installation and Operators Instruction Manual

TURBO Fiberglass Cone Fan and Grill Fan 48'' Belt Drive. Installation & Operator s Instruction Manual

High Plume Blowers Suggested Specification Section (Master Format 1996) Suggested Specification Section (Master Format 2004)

Heating Systems. Brooders, Space Heaters and QuadRadiant Heaters

Direct Fired Heater Model AD Specification

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION EXHAUST FANS

Propeller Fans. Industrial And Commercial Fans Belt And Direct Drive. Your Clean Air Source!

Heating Systems. Brooders, Space Heaters and QuadRadiant Heaters

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

UNIVERSITY OF ROCHESTER DESIGN STANDARDS NOVEMBER 1, 2013

Greater temperature control

Cages for Laying Hens. Our Experience. Your Success. Count on Chore-Time for experience, reliability, performance and confidence.

A. Codes and Standards that are Standard at the University:

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

Construction Standards Page Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA

AC, HP and Air Handler Units Up to 20 Tons. Commercial Split Systems. Reliable, cost-effective and servicefriendly split systems inside and out

A. Section Common Motor Requirements for HVAC Equipment: Fan motors.

CROSSFLOW FILM FILL PACKAGE COOLING TOWER. Number TYH SERIES LOW NOISE - ENERGY SAVINGS. Thermal-Cell Sdn Bhd ( M)

50Hz AC, HP and Air Handler Units Up to 70 kw. Commercial Split Systems. Reliable, cost-effective and servicefriendly split systems inside and out

Air Storm Fans. Air Storm 18 Fiberglass Fan Installation and Operation Manual

SECTION (15833) - HVAC POWER VENTILATORS

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION

What is a Closed circuit Cooling Tower (CCT)?

1.1 This section applies to air handling units for HVAC Systems.

Air Storm Fans. Air Storm 24 Fiberglass Fan Installation and Operation Manual

T-SERIES COMMERCIAL SPLIT SYSTEMS 6- TO 20-TON ELP/ELS MODELS UP TO 12.0 EER

SECTION DIRECT GAS-FIRED INDUSTRIAL HEATING AND VENTILATING UNITS

SECTION AIR HANDLING UNIT

AGRI-AIDE Ventilation Equipment. AGRI-AIDE Ventilation Key to Unlocking...

T-CLASS Commercial Split Systems Up to 20-Ton TSA/TPA Models

AMERICAN COOLAIR CORPORATION. Greenhouse Ventilation Systems. Farm Products Division

Series 5000 Industrial Modular Cooling Tower. Series 5000 Cooling Tower. engineering Data

Evaporator EM-1. Features. V.1. Ceiling Mount Evaporators

Performance and rugged durability. Commercial Split Systems Up to 20-Ton TSA/TPA Models

User Manual Box Exhaust Fan Series (Belt Drive)

Brooders. Better Brooding for Your Chicks... Since 1924

Smart Comfort Solutions HIGH VELOCITY DRUM FANS

A. This Section includes air-handling units with coils for indoor installations.

ALUMINUM REPAIR CERTIFICATION EQUIPMENT. Eliminate hazardous aluminum dust with a Eurovac system. BODY REPAIR CERTIFICATION EII Wet Mix Dust Collector

DUST COLLECTORS & DOWNDRAFT TABLES. A division of BLOWERS

A D VA N C E D E L E C T R O N I C G R A I N D RY I N G C O N T R O L S S Q S E R I E S D R Y E R S

Turning Air Into Solutions. TUBEAXIAL PAINT SPRAY BOOTH EXHAUST FANS. Model TCBS

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

Multistage Centrifugal Blowers

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS - CUSTOM

Direct Gas-Fired Make-Up Air

UNIVERSITY OF MISSOURI Central Station Air-Handling Units March

SPECIFICATION DELETED SECTION CENTRIFUGAL HVAC FANS

Air Storm Fans. Air Storm 54 Fiberglass Fan Installation and Operation Manual

Double Skin Air Handling Units

INSTALLATION and OPERATION BALL WASHER, HIGH CAPACITY MODEL NO: BW-022AN

MD Series MEDIUM DUTY SERVICE DOORS. superior product + recognized value

QuadraFlow Cooling Tower

VERTICAL FAN COIL UNITS

Smart Comfort Solutions HIGH VELOCITY DRUM FANS

57" Fiberglass Exhaust Fan with Cone

SECTION COOLING TOWERS

Square Ceiling Diffusers : All extruded aluminum constructions. Opposed blade damper is adjustable from face of diffuser. Available in square and

OFF-RIDGE VENTILATION PRODUCT BROCHURE

Bulletin FH05 FUME EXHAUST

A. General: Refer to paragraph entitled "SUBMITTAL" in Section Include the following data:

SECTION AIR DUCT ACCESSORIES

HOFFMAN & LAMSON ENGINEERED VACUUM SYSTEMS

True performance and rugged durability Commercial Air Conditioners and Heat Pumps TSA/TPA Models. Up to 15.0 SEER, and 9.0 HSPF

CONFINED SPACE VENTILATION

Booster Compressors N Series. Pressures to 650 psig Capacities 9.5 to 724 cfm

SECTION CUSTOM INDOOR CENTRAL-STATION AIR-HANDLING UNITS For large systems, 50,000 cfm or more.

PGF SERIES 7-1/2 Ton. Belt Drive CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT

ENVIRONMENTAL EQUIPMENT Poly-Vent

REFLECTOR PANS FOR HINGED ELEMENTS CONNECTOR BLOCK KIT TRIM RINGS FOR ABOVE PANS CONNECTOR BLOCK RANGE CORD REFLECTOR PANS FOR PLUG-IN ELEMENTS

SECTION AIR-COOLED SPLIT SYSTEM AIR CONDITIONING UNITS

Chilled Water DOAS Fan Powered Terminal Units

Screw Compressors SM SERIES. Capacities from: 16 to 54 cfm Pressures from: 80 to 217 psig

T-Class AC and HP Units Up to SEER and 9.0 HSPF. Commercial Air Conditioners and Heat Pumps. True performance and rugged durability

Belt Driven Mixed Flow Fans

Plenum Fans. Model HPA. Direct Drive

Guide Spec Summary. Option List. Date: 05/21/2001. EarthWise Modular Climate Changer Full Spec. Prepared by: Phone Number: Prepared for:

RELIABLE SOLUTIONS FOR INDUSTRIAL APPLICATIONS ENGINEERED VACUUM SYSTEMS

GENERAL OBSERVATIONS FROM THE PHES EVALUATIONS TO DATE AVERAGE ANNUAL PROPANE USE

INDUSTRIAL BLOWERS. With over 70 years of experience and expertise our fans will ensure your projects are a success.

FX5 Series Explosion-Proof Electric Air Heaters

Easy-to-read controller with large rheostat knob and start/stop switch. Explosion proof motor

Industrial Fans & Blowers

Wall fans. High air performance and low energy consumption

5 year fan housing and motor warranty

KCC Centrifugal Fan Air Cooled Condensers

Multistage Centrifugal Blowers

VENTLESS DOOR-TYPE DISHWASHER

Pocket Hardmount. Preventative Maintenance.

KHP Models. KHP Series. Heat Recovery Ventilator IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT

Industrial Space Heating Direct Gas-Fired Heating. Greenheat 50/50 Recirculation

Modular Supply Make-Up Air Unit

Centeral Station Air Handling Unit

University of Houston Master Construction Specifications Insert Project Name

AP- Series AeroPak Thru-The-Wall (Modular) Package Units Electric Cooling / Electric Heat Electric Cooling / Gas Heat Heat Pump / Electric Heat

A. American National Standards Institute (ANSI) : Establishes requirements applicable to certifying direct gas-fired heaters.

Evaporative Condensers

Transcription:

FANS and SHUTTERS Made to Work. Built to Last.

VANGUARD PLUS Fan with HYFLO Shutter Chore-Time s VANGUARD PLUS Cone Fan provides a great combination of performance, features and value. Add Chore-Time s HYFLO Fan Shutter for even greater efficiency. 48- and 52-Inch (121.9-cm and 132.1-cm) Factory-assembled using heavygauge, galvanized steel panels with screw fasteners and a galvanized steel blade. Automatic belt tensioning system uses an idler arm and pulley to maintain constant optimum belt tension on the fan s easy-to-change belt. Heavy-duty, cast iron, air-handler type bearings are self-aligning, pre-lubricated, and include a zerk fitting, as well as being shielded from moisture and dust. Chore-Time s HYFLO Shutter improves fan performance by minimizing obstructions during fan operation. Delivers up to 10% more air with 75% less opportunity for air to leak through compared to a traditional louver shutter. HYFLO Shutter doors are pushed open as air is exhausted when fan operates. HYFLO Doors do not suffer the typical 12-15% loss of efficiency and air speed typical of dirty louver-style shutters, so air speed is maintained over time. The HYFLO Shutter consists of only two moving parts for greater reliability and easier cleaning. Shutter s unique springs draw the doors closed when the fan is not in operation.

VANGUARD PLUS Fan with Louver Shutter Chore-Time s VANGUARD PLUS Slant-Wall Cone Fan offers a balance of performance, features and value, PLUS, greater flow volume, higher efficiency and quieter operation. 36-, 48- and 52-Inch (91.4-, 121.9- and 132.1-cm) Factory-assembled using heavy-gauge, galvanized steel panels with screw fasteners in a slant-wall style. Smaller fans have galvanized steel blades, while the 52-inch (132.1-cm) model has blades made of even heavier gauge galvanized steel. Automatic belt tensioning system uses an idler arm and pulley to maintain constant optimum belt tension on the fan s easy-to-change belt. Heavy-duty, cast iron, air-handler type bearings are self-aligning, pre-lubricated, and include a zerk fitting, as well as being shielded from moisture and dust. Easier access for wiring motor. Easy power cord access. Idler tensioner provides smoother operation and maintains constant optimum belt tension. Belled shutter has a curved, aerodynamic frame. Flexible louver edge helps seal the fan s opening.

TURBO Fan with Louver Shutter Chore-Time s TURBO Cone Fan provides high efficiency and corrosion resistance. One-piece cone improves air flow up to 14% and efficiency up to 21%. 14- through 48-Inch (35.6- through 121.9-cm) Corrosion-resistant, reinforced-fiberglass housing with aluminum motor mounts and a heavy cast-aluminum blade. Backed by Chore-Time s generous extended warranty including limited lifetime coverage for housing and blade, and a bonus year on motors. (See Chore-Time full written warranty for complete warranty details.) High CFM and CFM/watt, even under high static pressure. Heavy-duty, cast iron, air-handler type bearings are self-aligning, pre-lubricated, and include a zerk fitting, as well as being shielded from moisture and dust. Chore-Time s 48-inch (121.9-cm) fan is also offered in a light-restricting version with a black interior housing surface and a black cone. Grill simply snaps into impact-resistant, polyethylene, one-piece cone with no fasteners required. Chore-Time s Louver Shutters come in an aerodynamic belled style frame for greater efficiency as well as in a flat frame model for flush mounting. Available in white or gray. Louvers flexible edge helps seal the fan s opening when fan is at rest. Corrosion-proof vinyl construction with a rigid vinyl frame and fiberglass rod hinges for the louvers. HELP SEAL OUT DRAFTS during cold weather with optional 36- or 48-inch (91.4- or 121.9-cm) cone covers made of vinylcoated, ultravioletresistant fabric. Louvers are easy to replace and have a smooth, easy-care finish for low maintenance.

TURBO Fan with HYFLO Shutter Chore-Time s TURBO Cone Fan is now available with Chore-Time s HYFLO Fan Shutter for even greater efficiency. (Patent Pending) 52-Inch (132.1-cm) Only Doors are pushed open as air is exhausted when fan operates, while shutter s unique springs draw the doors closed when the fan is not in operation. Patent Pending Chore-Time s high-capacity 52-inch (132.1-cm) diameter TURBO Fan with HYFLO Shutter delivers more air with fewer fans 29,700 CFM at 0.05 inches of static pressure in recent independent wind tunnel tests. Sturdy, corrosion-resistant fiberglass housing with cast aluminum blade and corrosion-resistant components. One-piece, impact-resistant, polyethylene cone has 64-inch (162.6-cm) outside diameter, but can be compressed for 60-inch-on-center (152.4-cm) installation. Automatic belt tensioner uses arm and pulley arrangement to provide consistent belt tension. Heavy-duty, cast iron, air-handler type bearings are self-aligning, pre-lubricated, and include a zerk fitting, as well as being shielded from moisture and dust. Fans are shipped fully assembled including shutter doors. At installation, simply attach fan to house sidewall, add one-piece cone, and snap grill in place. Unit installs flush on inside of house. Backed by Chore-Time s generous extended warranty including limited lifetime coverage for housing and blade, and a bonus year on motors. (See Chore-Time full written warranty for complete warranty details.) Wire and spring attachment between doors keeps doors together, but allows them to float left or right for maximum efficiency. Chore-Time s HYFLO Shutter minimizes obstructions during fan operation and seals tighter when not operating. Users may choose black or white for housing interior and cone. Housing exterior is white. Delivers up to 10% more air with 75% less opportunity for air to leak through compared to a traditional louver shutter. HYFLO Doors do not suffer the 12-15% loss of efficiency and air speed typical of dirty louver-style shutters, so air speed is maintained over time. The HYFLO Shutter consists of only two moving parts for greater reliability and easier cleaning.

FAN SPECIFICATIONS METAL CONE FANS SPECIFICATIONS VANGUARD PLUS FAN WITH HYFLO SHUTTER 52-Inch (132.1-cm) Fans with HYFLO Shutter (1 Phase) BD Standard 48483-22 28,000 27.5 26,200 24.0 24,400 21.0 0.77 03002 BD High-Capacity 48483-21 30,800 23.2 29,400 20.8 27,300 18.3 0.77 03001 52-Inch (132.1-cm) Fans with HYFLO Shutter (3 Phase) BD Standard 48483-42 28,000 27.7 26,400 24.8 24,600 21.3 0.77 03003 BD High-Capacity 48483-41 30,900 23.6 29,500 21.2 27,500 18.8 0.77 03004 48-Inch (121.9-cm) Fans with HYFLO Shutter (1 Phase) BD Standard 49515-22 22,400 28.3 21,100 24.4 19,600 21.3 0.77 04326 BD High-Efficiency 49515-23 21,400 31.0 20,000 26.5 18,600 23.2 0.75 04325 BD High-Capacity 49515-21 26,200 23.4 24,600 20.8 22,700 18.0 0.76 04327 SPECIFICATIONS VANGUARD PLUS SLANT WALL FAN WITH LOUVER SHUTTER 52-Inch (132.1-cm) Fans with Bell Louver Shutter (1 Phase) BD Standard 48319-225V 25,900 26.7 24,500 23.7 22,800 21.0 0.72 02184 BD High-Capacity 48319-215V 28,400 24.0 26,800 21.3 25,100 18.9 0.76 02185 48-Inch (121.9-cm) Fans with Bell Louver Shutter (1 Phase) BD Standard 48318-225 22,000 26.3 20,700 23.2 19,200 20.2 0.75 04321 BD High-Efficiency 48318-235 20,700 28.8 19,400 25.1 18,000 21.8 0.73 04322 BD High-Capacity 48318-215 25,800 22.4 24,400 20.3 22,900 18.0 0.77 04323 36-Inch (91.4-cm) Fans with Flat Louver Shutter (1 Phase) DD Standard 44860-3622 10,860 20.1 10,210 17.9 9,460 15.9 0.75 99217 FIBERGLASS CONE FANS SPECIFICATIONS TURBO FAN WITH HYFLO SHUTTER 52-Inch (132.1-cm) Fans with HYFLO Shutter (1 Phase) BD Standard 49740-22 28,700 26.4 27,000 23.5 24,900 20.8 0.73 04334 BD High-Capacity 49740-21 30,700 21.8 29,700 20.5 27,700 18.3 0.79 04312 52-Inch (132.1-cm) Fans with HYFLO Shutter (3 Phase) BD Standard 49740-42 28,800 26.3 27,100 23.3 24,800 20.5 0.73 04335 BD High-Capacity 49740-41 N/A N/A 29,700 20.3 27,900 18.2 0.79 04318 SPECIFICATIONS TURBO FAN WITH LOUVER SHUTTER 48-Inch (121.9-cm) Fans with Bell Louver Shutter BD 48-Inch Standard 38264-4825 25,200 23.9 23,600 21.2 22,100 19.0 0.74 04332 BD 48-Inch High-Cap. 47898-4825 27,700 19.6 26,400 18.0 24,960 16.3 0.83 02473 36-Inch (91.4-cm) Fans with Flat Louver Shutter DD 36-Inch (91.4-cm) 38265-3622 11,710 20.5 10,970 18.6 10,200 16.8 0.73 96159 BD 36-Inch (91.4-cm) 38589-3622 12,640 20.8 11,960 19.0 11,190 17.0 0.79 96199 Variable Speed Fans with Flat Louver Shutter DD 24-Inch (61.0-cm) 40452-2422 6,400 17.8 5,990 16.2 5,550 15.0 0.73 98012 DD 18-Inch (45.7-cm) 40452-1822 4,180 15.2 4,014 14.1 3,870 13.0 0.87 98008 DD 14-Inch (35.6-cm) 40452-1422 2,120 14.8 2,030 13.8 1,910 12.6 0.78 98059 Poultry Production Systems Chore-Time Brock International Divisions of CTB, Inc. Phone: 574.658.4101 or 574.658.9323 (International) Internet: www.choretime.com or www.ctbworld.com E-Mail: choretime@choretime.com CT-2298/0506