TraceTek FIND LEAKS BEFORE THEY FIND YOU

Similar documents
Leak Detection and Location Systems

FIND LEAKS BEFORE THEY FIND YOU. Leak Detection and Location Systems

Water Leak Detection Find Leaks Before They Find You

Industrial Strength Leak Detection

water leak detection

TTSIM-1A. TraceTek Sensor Interface Module with Relay. Installation/Operation Instructions. Installation Items (not supplied) Tools Required.

Fuel Leak Detection Find Leaks Before They Find You

TraceTek TT1000 Modular Sensing Cable

Industrial Strength Leak Detection

Liebert. Liqui-tect Leak Detection and Reporting Comprehensive Detection of Water Based Leaks in Critical Spaces

Gardian W51. Approvals

RayClic Connection System

PRODUCT SELECTION GUIDE FOR WATER SENSING SYSTEMS

TE Connectivity's AMP NETCONNECT Cable Management

TraceTek Leak Detection

ACCS-30. Multipoint commercial heat-tracing control system

AquiTron. AT-LDM Liquid Detection Module INSTALLATION INSTRUCTIONS

PolySwitch TS600 Overcurrent Protection Devices

C A Heating Cable Gland Kit

Raychem Heating System

C910 Series. Single-point heat-tracing control system

FIST-EDSA-D4. 3 Feeder cable/ducts (max 16 mm) 4 Drop cable (DB cable or guiding tubes 5-8 mm) 5 Adding drop cable. 6 Gel part replacement

PT9600. Cable Actuated Encoder Reel. General. Environmental

fuel leak detection find leaks before they find you

Tyco Thermal Controls provides complete heat tracing and speciality. wiring solutions for the industrial, commercial, and residential markets.

QuickStat-TC Installation & Operation Manual

Installation, Operation and Maintenance Manual

Gas Discharge Tubes GTCX25-XXXM-R02 Series

Flexible Air-sampling Smoke Detection

PT9150 (Extended Range)

Gas Discharge Tubes GTCX28-XXXM-R05 Series

aquilar - leak detection solutions

Supervisor Standard Edition

Commercial and Residential Self-Regulating Heating Products

JBM-100-LBTV2 Power Connection, Powered Splice, Dual Power Connection, or Splice with Junction Box

PT9420 (Extended Range)

Technical Manual. LeakFilm Sensor. Film Type Liquid Leak Detection Sensor


TT7000-HUV TraceTek Sensing Cable for Strong Mineral Acids

DATASHEET PolySwitch RKEF Devices

Specification Status: Released

Raychem Overvoltage Devices. ROV14, ROV14H, ROV14E 14mm Series Metal Oxide Varistors

Side Entry Bushing (SEB) High Temperature Cable Clamp Bushing Installation Instructions

FAAST. Fire Alarm Aspirating Sensing Technology

METPOINT THE COMPLETE RANGE OF PRECISION CONTROL DEVICES FOR COMPRESSED AIR DEW POINT, FLOW, AND LEAKAGE

TTSIM-1 Sensor Interface Module

Small Box for Cable Termination. 3.1 Preparation of box 3.3 Mounting of the box on the wall

DEW POINT HYGROMETER MODEL DPH-2020/2012 BULLETIN DPH-2020/2012 can be used to extend the lower measurement limit of the system.

AquiTron. AT-WM Water Monitor DATA SHEET

Specification Status: Released

Raychem Overvoltage Devices. ESD Protector PESD BENEFITS FEATURES APPLICATIONS MATERIALS INFORMATION PART NUMBERING.

AT-G-SENSE Gas Sensing System

A world of fiber Product overview

S AGE E NGINEERING A SSOCIATES, LLP

C Electrical Connection Kit

Seal Kits for BUDI Enclosures

DESIGN & APPLICATION GUIDE. Digital Liquids Leak Detection Systems

Cable Actuated Sensor Industrial User Scalable 4 20mA

Raychem Overvoltage Devices. ROV05, ROV05H 5mm Series Metal Oxide Varistors

Z-PACK TinMan 85 ohm Connector Overview

IR4000. Point Infrared Combustible Gas Detection System. The Reliable and Flexible Safety Solution That s Low Maintenance

PT9101. General. Potentiometer Cycle Life 250,000 Maximum Retraction. Weight, Aluminum (Stainless 8 lbs. (16 lbs.) max. Electrical

HTF3000LF PVH-3.3 TEMPERATURE AND HUMIDITY MODULE

MS1471 SPECIFICATIONS. PC Board Mountable Pressure Sensor 0-60 mv Output Gage and Absolute Low Cost

READ AND SAVE THESE INSTRUCTIONS DRANE-KOOLER. Water Tempering Device. Installation, Operation, and Maintenance Manual

AUTROSAFE 4 A new level in interactive fire detection systems

SGJ. 80, 120-inch Stroke Range Options. Polycarbonate Enclosure IP67. In Stock for Quick Delivery. General. CANbus Specifications

Technical Paper. PPTC Circuit Protection for Power Management in Portable Communications/PDA Equipment

The DEF-System by BRUGG. The Best Way to defeat the problem of DEF heat Installation Instructions

Aspiration Systems for Smoke Detection

ED-18 Analog Output Series Magnetic Encoder SPECIFICATIONS

Energy Division. Bowthorpe MV Surge Arresters OCP, Open Cage Polymeric series

Steam Humidification Light Commercial Applications. Better technology means better business.

AUTROSAFE. An interactive fire detection system for larger vessels

FAAST. Fire Alarm Aspirating Sensing Technology

Telecom Fuses. Benefits. Features. Applications

Industrial Applications

FOSC. Fiber Optic System Technology. Fiber Optic Splice Closures (FOSC-400)

Refrigerated Dryers. Cycling; Non-Cycling; High Pressure; High Temperature ,000 scfm

Gas Discharge Tubes. Features: Benefits: Applications:

The World's No. 1 Brand of Air-sampling Smoke Detector

PT101. General. Full Stroke Range Options. Potentiometer Cycle Life Maximum Retraction Acceleration. Electrical

ENERGY /// RAYCHEM CABLE CLAMPS RAYCHEM CABLE CLAMPS. Quick Reference Guide

Cable Actuated Sensor Industrial Incremental Encoder Output

U86B. Urea Dosing SPECIFICATIONS FEATURES APPLICATIONS

aquilar - leak detection solutions

Next Generation Corona Discharge Auto Voltage Sensing Installation Manual

Alfa Laval Touch Control

TraceTek TT1000 Modular Sensing Cable

HART XL High Sensitivity Smoke Detection

The Importance of Pressure Sensors in HVACR Systems

OPERATION MANUAL MODEL & ACCELEROMETER

Cable Actuated Sensor Industrial User Scalable VDC Output

Please Read and Save These Instructions.

MEAS SENSOR TAG APP INSTALLATION GUIDE FOR IOS

CIRRUS PRO. User Manual and Responsibilities ASPIRATING FIRE DETECTOR

Monitoring Solutions

TTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS

A2Z Ozone, Inc. PRODUCT MANUAL

Refrigerated Dryers. Cycling; Non-Cycling; High Pressure; High Temperature ,000 scfm

Transcription:

TraceTek Leak Detection and Location Systems FIND LEAKS BEFORE THEY FIND YOU

DON T TAKE THE RISK tank room chiller plant room services riser ven small leaks in the wrong places cause downtime, disruption, and costly damage. And the aftermath ties up resources in clean-up and repair. Why suffer these costs when reliable, distributed leak Edetection is available? TraceTek technology lets you detect leaks at their source executive office / board room vending areas IT facility network / server / equipment room perimeter heating / cooling services core toilets / washroom kitchen / lunchroom fan coil units archives LV / HV switch room even pinpoint their location so you can stop damage before it starts. Thousands of facilities throughout the world rely on TraceTek leak detection systems to protect data and telecommunications centers, commercial buildings of all kinds, libraries and archives, and museums. DISTRIBUTED VS. POINT SENSING With the point sensing approach to leak detection, liquid must reach the location of a probe to trigger an alarm. Depending on the circumstances, a leak may grow or spread considerably before it reaches an individual probe. With distributed sensing, liquid is detected if it makes contact anywhere along the length of sensing cable that monitors and entire area. routing the cable near likely sources of leaks and spills ensures early detection. A locating module even displays the distance to the leak, enabling quick and effective response. Point Sensing elevator pit plant room archives storage PABX comms room generator room / oil storage UPS room Distributed Sensing cable entry chamber A TraceTek locating system detects the leak at its source, signals the alarm, and displays the exact distance to the leak. By referring to a map of the system layout (supplied as part of the TraceTek system), you can quickly locate the leak source. TraceTek TTDM 1

UNDETECTED LEAKS EVEN SMALL ONES CAN BE DEVESTATING PROBLEM AREAS: hat happens if the plumbing above a building s Heating/cooling water supply and return piping Condensate drains network equipment springs a leak? Or a bathroom sink next to an order processing center backs up? WThe amount of business disruption that s possible is staggering Fire sprinkler systems Toilets, drains, and related plumbing particularly if the leak goes unnoticed for any length of time. Basements CATCH IT EARLY, STOP IT FAST Backfl ow preventors As soon as even a little water touches the sensor cable, Roofs the TraceTek system triggers an alarm. Because TraceTek cable Coffee and vending machines Overhead pipe runs and trays POTENTIAL CONSEQUENCES: Business disruption Service interruption and network outages Loss of telephone service senses water along its entire length not just certain isolated points you can rely on early detection. In offi ce environments the TraceTek system helps avoid costly damage and disruption that can result from leaks. HVAC equipment TraceTek cable monitors water-heated or cooled ventilation equipment. If a leak is detected, the system automatically shuts off a supply valve to prevent costly damage to offi ce equipment. Liability for damage to tennant s equipment Damage to furnishings Cleanup costs Telephone switch gear TraceTek sensing cable monitors overhead piping to guard sensitive telecommunications hardware. The TraceTek module can instantly relay an alarm to your building management system or alarm panel. APPLICATION AREA: Raised fl oor computer facility ISP/co-location facilities Fiber optic switch sites Racked equipment Control rooms Trading rooms Archival storage Executive offi ces PBX rooms, room server equipment rooms Museums, historic buildings FLEXABLE TO FIT ANY APPLICATION The design ßexibility of the TraceTek system allows you to select the monitoring approach and layout you need no matter how simple or complex your requirements. And the TraceTek system is easily integrated into a building management system. NO DOWNTIME TraceTek water sensing cable is designed to dry almost instantly, making it easy to quickly get the system up and running again after an alarm. As soon as moisture is cleared away from the cable, you can restore the system to operation. Mehchanical or electrical equipment areas TraceTek systems provide 24-hour leak detection on unmonitored basement and equipment fl oors. TraceTek fuel-sensing cable is available for backup diesel generators and other fueling applications. Building servie columns Leaks in vertical service columns often propagate to several fl oors. TraceTek systems offer layout fl exibility to handle widely distributed areas with branches or zones. Sensing cable on each fl oor provides early and quick detection and the alarm and locating module pinpoints the location. 2 3

DOWNTIME SPELLS DISASTER PROBLEM AREAS: Chilled water piping Air conditioning units f you design or manage a computer network, a multi-tenant server facility, or telecommunications facility, you know the importance of keeping systems continually on-line. Service reliability is a key element of your value Iproposition. To avoid downtime and disruption, consider installing a system that Overhead piping Cracks in substructure Roofs Toilets, drains, and related plumbing POTENTIAL CONSEQUENCES: Downtime Cleanup costs and disruption Loss of telephone network service Equipment damage Placed in the subfl oor of a computer room, the TraceTek system protects your computer equipment by detecting a leak early and even locating its source. can Þnd a leak at its source, when it occurs and can pinpoint its location. Computer rooms In a raised-fl oor computer room, the TraceTek system provides distributed coverage that fi nds a leak before it becomes a problem. Cable is laid out at the perimeter of a room, near drains, water piping, and air conditioning. LOCATE THE LEAK FAST For hidden or unmonitored areas, the TraceTek system not only provides early detection, but also a digital readout of the distance to the leak. The TraceTek system map (supplied as part of a TraceTek locating system) leads you to the leak, so you can locate the source, solve the problem, and keep your equipment up and running. MODULAR NETWORK, DISTRIBUTED SENSING As modern data and network facilities have grown in complexity, the TraceTek system has added design and integration ßexibility. Single TraceTek alarm panels can now monitor up to 32 individual circuits or inexpensive Sensor Interface Modules can provide leak detection data directly to Building Management Systems. Network equipment Network servers and routers are sometimes housed in rooms not specifi cally designed for their protection. TraceTek cable can be installed to monitor hazards wherever they occur. For example, cable is placed at the perimeter of subfl oors and in trays below overhead piping. Telephone equipment rooms The TraceTek system protects you from loss of telephone service by providing monitoring directly below water piping and at a room s perimeter. Leaks can be detected early and stopped before disruption occurs. 4 5

ONE LEAK CAN RUIN YOUR COLLECTION PROBLEM AREAS: Aged water supply piping Basements Fire sprinkler systems Janitorial maintenance areas Heating and cooling water, supply and return Toilets, drains, and related plumbing POTENTIAL CONSEQUENCES: Loss of irreplaceables: artwork historic archives business records Costs of restoration Facility closures n a museum, archive, library, or storage setting, any undected leak is truly a disaster. Sources include roof leaks, basement seepage, and in most buildings a disconcerting variety of plumbing: overhead sprinklers, water Isupply piping, even bathrooms and water fountains. The ßexibility of the TraceTek system allows you to design the monitoring and cable layout required no matter In areas where irreplaceable valuables are stored, the TraceTek system provides continuous monitoring and leak detection. how simple or complex. You can install sensing circuits ranging from 3 feet to 5,000 feet. Whether you require a simple alarm system for a single room or a multiple circuit sensor network for a large facility, there is a TraceTek system to Þt your needs. Restrooms and service areas Whatever the risk to your valuables, the TraceTek system offers the flexibility to install a simple alarm system or a complex, multibranch locating system. Archives with sprinkler systems TraceTek sensing cable is installed in a tray below sprinkler system piping. By directly monitoring the sprinkler system and water supply piping, leaks are detected early, before they can do a lot of damage. Basement storage TraceTek cable provides constant monitoring of unmanned locations such as basement storage areas, where overhead water pipes and seepage or flooding present risks. Early warning can help prevent disaster. 6 7

SIMPLE. RELIABLE. FLEXIBLE. Unique sensing cable Distributed sensing: by sensing liquid along its entire length, TraceTek cable makes it possible to detect leaks at their source Durable construction: small but rugged cable is extremely resistant to corrosion and abrasion Dries and clears quickly: cable construction leaves virtually no place to trap moisture Simple and sure detection circuit that can also locate Continual check of system integrity: TraceTek cable uses a four-wire construction. Monitoring the two circuit loops provides a continual and positive verifi cation of system integrity. Simple and sure detection: liquid creates a circuit between the sensing wires to trigger an alarm no moving parts, no claibration. Accurate location: a TraceTek locating system pinpoints (0.1% precision) where liquid contacts the sensing cable. The locating module measures the current and the voltage drop in the second sensing loop and simply applies Ohm s law (R=V/I) Clear indication: LEDs clearly indicate system status monitoring, leak, or fault. Modular for ease of design and installation Standard lengths of TraceTek cable quickly plug together so you don t need special tools to install the system. The modular design also means that you can easily add to the system in the future. Flexible with a choice of systems and interfaces to meet your needs There s a TraceTek system to meet your needs, whether you re looking for a simple detection system (for a small, isolated area) or for a complex, multi-branched locating system. All TraceTek modules have relays to signal detection of an alarm condition (for example, to a building management system). Our locating system also displays the distance to the leak. continuity wire signal wire sening wire jacketed with conductive polymer (no exposed metal to corrode) end termination connects wires to make two circuit loops Our microporcessor-based alarm and locating module continues to monitor after a leak and realarms if any major change occurs. It keeps a log of events and has built-in systemwide diagnostic functions. In addition to alarm relays, its interface include a 4-20 ma current transmittor and an RS-232/RS-485 communications port. 8 9

Distributed By: ISO 9001 Flow Control Tyco Thermal Controls Important: All information, including illustrations, is believed to be reliable. Users, however, should independently evaluate the suitability of each product for their particular application. Tyco Thermal Controls makes no warranties as to the accuracy or completeness of the information, and disclaims any liability regarding its use. Tyco Thermal Controls only obligations are those in the Tyco Thermal Controls Standard Terms and Conditions of Sale for this product, and in no case will Tyco Thermal controls or its distributors be liable for any incidental, indirect, or consequential damages arising from the sale, resale, use, or misuse of the product. Specifi cations are subject to change without notice. In addition, Tyco Thermal Controls reserves the right to make changes without notifi cation to Buyer to processing or materials that do not affect compliance with any applicable specifi cation. Worldwide Headquarters Tyco Thermal Controls 300 Constitution Drive Menlo Park, CA 94025-1164 USA REPRESENTED BY: G.A. Fleet Associates 55 Calvert Street Harrison, NY 10528 Tel (914) 835-4000 Fax (914) 835-1331 TraceTek and Raychem are trademarks of Tyco Thermal Controls LLC.