Leak Detection and Repair METHOD 21 AND OPTICAL GAS IMAGING

Similar documents
Heath Consultants Overview of Infrared Optical and Laser Leak Detection Technologies in the Natural Gas Industry.

INDEX 100 GENERAL 101 PURPOSE 102 EXEMPTION, VACUUM CONDITION 103 EXEMPTION, VAPOR PRESSURE

Thermo Scientific TVA2020 Introduction

This SOP and the B.C. Field Sampling Manual are available at: www2.gov.bc.ca.

Copyright 2016 ALL Consulting

Updated Leak Detection & Location Technology

The Louis Berger Group, Inc. 15 January 2016

Leveraging Thermal Imaging for Gas Detection

A Cost Effective Multi-Spectral Scanner for Natural Gas Detection

ENVIRON INTERNATIONAL CORPORATION THE USE OF A GAS-IMAGING DEVICE FOR DETECTING FUGITIVE EMISSIONS IN ETHYLENE FACILITIES

NJSP HMRU. Module 5 B HM Operations 1

Refrigerant Management Requirements Update

High-Altitude, Aerial Natural Gas Leak Detection System

HFID Heated Total Hydrocarbon Analyzer Module

Process Control PIP PCEA001 Fixed Gas Detection Guidelines

FLIR Optical Gas Imaging

Under Section 608 of the CAA, EPA has established regulations (40 CFR Part 82, Subpart F) that:

If searching for the ebook Rae pid manual in pdf format, then you have come on to the faithful website. We furnish the complete option of this book

VOCs in soil remediation

Low-Cost Standoff Laser Sensing for Smart LDAR

EAGLE 2. 6 Channel Capacity. Inlet fitting. Loud buzzer (95dB) IrDA communication port Low flow shutoff and alarm Alarm LED s with wide visibility

Title: Standard Operating Procedure for Measurement of Total Hydrocarbon Using a Flame Ionization Detection

SAMPLE SPECIFICATIONS CONTINUOUS MONITORING SYSTEM (Insitu)

Methane to Markets Oil and Natural Gas Technology Transfer Workshop

Corpus Christi - Air Monitoring Project

Series 9000 Total Hydrocarbon Analyzer

Polytector III G999 for Ex zone 0

TECHNICAL NOTE. Response Factors for Flame Ionization Detector Operation FLAME IONIZATION DETECTOR OPERATION BASICS

Laser Analyzers for NH3 Safety Monitoring and Leak Detection

COURSE 474 CONTINUOUS EMISSION MONITORING Extended Agenda

Ministry Ministère Order Issued Pursuant to s.35(14) of of the de O. Reg. 419/05 Environment l Environnement. Benzene and Climate et de l Action en

The licensee shall take the actions specified to close out the non-compliances and observations raised in this Site Visit Report.

PHILADELPHIA GAS WORKS REQUEST FOR INFORMATION. Alternative Natural Gas Leak Detection Measures. Dated: February 18, 2014

REFRIGERANT PROCEDURE

Operation and Maintenance Manual

Monitoring Flammable Vapors and Gases in Industrial Processes

Emissions: Plants Plug Away at Leaks

PERGAM GAS LEAK DETECTION

Cryogenic cooling with CUMULUS LF.

Compact Sensor Heads for In-situ and Non-Contact Standoff Gas Sensing using TDLAS in Harsh Environments

FIXED GAS DETECTORS PDF

Subpart M National Perchloroethylene Air Emission Standards for Dry Cleaning Facilities

NUCLEAR REGULATORY COMMISSION. [Docket No ; NRC ] Exemption Requests for Special Nuclear Material License SNM-362,

Ozone Depleting Substances (ODS) Rule Updates

HEATH PIPELINE SERVICES PTY LTD

Recent Improvements in Process GC Instrumentation

HESAI. HS-4000 Laser-Based Remote Methane Leak Detector

LFL Monitoring. MEGTEC Systems

Company facts. ! Photoacoustic Spectroscopy (PAS) and! Fourier Transform InfraRed (FTIR) principle

INSTRUCTION MANUAL. 851 Transport Drive Valparaiso, IN SENSIT Technologies is in compliance with ISO 9001:2008.

FIRE & SAFETY SPRING 2016 EDITION

MW-401B Area Soil Remediation Report

Boiler MACT Webinar Q/A

Portable Gas Detection Practice

Gas Detection. - Disposable - Serviceable. Single Gas Detectors

LaserMethane mini (LMm)

AVIATION TECHNOLOGY SERVICES: PIPELINE LEAK DETECTION

FIXED GAS ANALYZER (FGA)

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

Ministry Ministère Order Issued Pursuant to s.35(14) of of the de O. Reg. 419/05 Environment l Environnement and Climate et de l Action en.

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

Many different instruments Many different operating principles including: May sample many different gases & vapour From relatively simple to complex

Process and Air Monitoring. Online GC systems for continuous monitoring of organic compounds in air and gaseous samples

EPA/ODEQ DEMOLITION BY FIRE REQUIREMENTS

Flammable and Toxic Gas Detection

Gas Trac LZ-50 INSTRUCTION MANUAL. SENSIT Technologies is in compliance with ISO 9001: Transport Drive Valparaiso, IN

GAS ANALYSIS / DETECTION Gas Detector

Microtector II G gas-detector with performance test approval. Worldwide Supplier Of Gas Detection Solutions

Complete Gas Analysis

GasAlertMicro 5. 1, 2, 3, 4, and 5 Gas Detectors. Quick Reference Guide

LGCNCOE Study Guide: Fixed Gas Detection

White paper on the Dielectric Barrier Discharge Detectors. Introduction:

Pipeline Personnel Qualification. ASME B31Q Update. Presented by: Mike Gruenberg Southwest Gas Corporation

SOLAR CELL PRODUCTION REQUIRES EFFECTIVE METROLOGY

Chemistry Instrumental Analysis Lecture 4. Chem 4631

SPECTRAL INSTRUMENTATION

Selecting the right generator for your GC system. By Ed Connor, GC Product Specialist, Peak Scientific Instruments Ltd

Senscient s team has more than 150 years collective experience in gas. detection.

User s Manual IS MODEL

SENSIT FIRE SERVICE. 4Hazardous Gas Monitors 4Gas Leak Detectors 4Calibration Stations 4Data Management EMERGENCY RESPONSE

IR IN MODERN TECHNOLOGY 1. Infrared Radiation in Modern Technology. Brian D. Dold. Brigham Young University - Idaho

Properly calibrating catalytic bead sensors: A practical guide

Drying Laboratory Methods Drying Parameter Characterization from Small Size Samples

CCTV, HOW DOES IT WORK?

Choosing the best detection technologies for measuring combustible gas and VOC vapors

NACT 287 Dry Cleaning

Division F Of G Of The 1987 Standard Industrial Classification Manual

MEMORANDUM. TERESA McCLISH, COMMUNITY DEVELOPMENT DIRECTOR

Thank You for Attending Today s Webinar:

PROPOSED October 15, 2013

Personal & Portable Gas Monitors

Inspection Machines Ampoules, Vials, Cartridges, LVP, Pre-filled Syringes. When Inspection Needs Perfection

HESAI. HS-5000 Drone-Mounted Natural Gas Surveillance System

GfG Instrumentation Inc.

Decision Notice. Proposed Action

T.ex Single Gas Detector VISA

ALTAIR 5X Multigas Detector

Product Selection Guide Fixed Gas Detection Systems for Personnel & Equipment Safety

PRODUCT GUIDE. ionscience.com Unrivalled Gas Detection.

CombustionONE. Improving and Sustaining the Combustion Asset. Driven by the New Standards. Bulletin 53A90A01-01E-A

Transcription:

Leak Detection and Repair METHOD 21 AND OPTICAL GAS IMAGING

LT Environmental, Inc. www.ltenv.com

Today we will discuss: Method 21 Devices Combining Optical Gas Imaging (OGI) with Method 21 Federal Programs: Method 21 and Alternative Work Practice NSPS Subpart OOOO revisions

EPA Method 21 (40 CFR Part 60, Appendix A-7) Determination of Volatile Organic Compound Leaks Describes specific devices that can be used: General requirements: Intrinsically safe Constant intake pump Detect gas

Photoionization Detector: Advantages Lightweight Easy Calibration Disadvantages VOC only (no methane) May not calibrate to meet all leak definitions

Flame Ionization Detector: Advantages Detects methane Can calibrate to multiple leak definitions (500ppm, 10,000ppm, etc..) Disadvantages: Bulky/Heavy Need UHP Hydrogen Pilot frequently goes out

Flame Ionization Detector: MicroFID Smaller, but same advantages/disadvantages

Infrared Absorption Detector: Advantages Can detect methane Lightweight Calibrates to multiple leak definitions (500ppm or 10,000ppm) Disadvantages Sensor reads in %LEL not ppm, must convert to ppm (%LEL x 10,000)

Forward Looking Infrared (FLIR)

Or there s always this..

Choose the right tool for the job PID calibrates with isobutylene (VOC) FID/Infrared Absorption calibrates with Methane (Hydrocarbon) Most regulations are focused in Hydrocarbon leaks, which is a major component of natural gas (~70%)

State Leak Detection Regulations Colorado Colorado Regulation 7 XVII.F.6.e. For leaks identified using an approved instrument monitoring method or AVO, owners or operators have the option of either repairing the leak in accordance with the repair schedule set forth in Section XVII.F.7. or conducting follow-up monitoring using EPA Method 21 within five (5) working days of the leak detection. If the follow-up EPA Method 21 monitoring shows that the emission is a leak as defined in Section XVII.F.6., the leak must be repaired and remonitored in accordance with Section XVII.F.7.

State Leak Detection Regulations Colorado Leak definition = 500ppm Hydrocarbon PID vs FID

State Leak Detection Regulations Colorado XVII.F.7.c. Leaks discovered pursuant to the leak detection methods of Section XVII.F.6. shall not be subject to enforcement by the Division unless the owner or operator fails to perform the required repairs in accordance with Section XVII.F.7.

State Leak Detection Regulations Wyoming Operator must develop LDAR protocol Best Available Control Technology (BACT) >8 TPY (attainment area) or >4 TPY (non-attainment area) Method 21, OGI Camera, AVO or a combination thereof Does not negate other Federal LDAR requirements : Kb, OOOO, KKK

State Leak Detection Regulations Utah ILB.l0.a.1 (General Approval Order)A reading of 500 ppm or greater with an analyzer or a TDLAS [tunable diode laser absorption spectroscopy] shall be considered a leak. Any emissions detected with an infrared camera shall be considered a leak unless the owner/operator evaluates the leak with an analyzer meeting U.S. EPA Method 21, 40 CFR Part 60, Appendix A no later than 5 calendar days after detection and the analyzer's reading is less than 500 ppm.

State Leak Detection Regulations Utah In conversations with the State; VOC is the gas component of concern A PID analyzer calibrated to 500ppm

Federal Leak Detection Regulations Optical Gas Imaging NSPS Subpart A 60.18(g) Alternative Work Practice IR Camera allowed for any NSPS requiring a Method 21 monitor except: Closed Vent Systems Equipment designated as leakless Equipment identified as no detectable emissions (leak definition 500ppm)

Federal Leak Detection Regulations Some Oil and Gas regulations that require monitoring: NSPS Subpart Kb NSPS Subpart KKK NSPS Subpart OOOO

Federal Leak Detection Regulations NSPS Subpart Kb Closed Vent systems for storage tanks (after custody transfer) Method 21 only

Federal Leak Detection Regulations NSPS Subpart OOOO Closed Vent system inspections Method 21 only Closed Vent Natural gas processing plant inspections Method 21 only 500ppm definition

Federal Leak Detection Regulations NSPS Subpart KKK (applicable January 20, 1984 August 23, 2011) Potential for alternative work practice Not applicable for facilities constructed after August 23, 2011

Proposed Changes to Federal Rule NSPS Subpart OOOO Revisions Proposed changes to existing rule Published September 18, 2015 EPA soliciting comments through November 17, 2015

Proposed Changes to Federal Rule Well Sites: Proposing facility-wide OGI camera inspections Within 30 days of well completion/modification Inspections done semi-annually Alternate proposal would require annual inspections Soliciting comment on requiring quarterly inspections

Proposed Changes to Federal Rule Well Sites: May exclude sites that are wellhead only May exclude low production sites (<15 bopd)

Proposed Changes to Federal Rule Compressor Stations: Proposing facility wide OGI camera inspections Within 30 days after startup or modification Inspections done semi-annually

Proposed Changes to Federal Rule Re-inspections: Proposing that Method 21 could be used for re-monitoring Consideration of cost of re-hiring OGI personnel for re-inspection Repaired if re-monitor shows leak is <500ppm above background

Proposed Changes to Federal Rule Be informed Submit comments to EPA by November 17, 2015 Know your leak detection options

www.ltenv.com