Air Sampling Smoke Detection

Similar documents
Honeywell Air Sampling Devices Data Sheet

Honeywell Air Sampling Devices Data Sheet

Notifier by Honeywell: FAAST TM Fire Alarm Aspiration Sensing Technology

Input/Output Modules Data Sheet

Notifier by Honeywell: FAAST TM Fire Alarm Aspiration Sensing Technology

Installation Instructions for Honeywell ALL-SPEC Air Sampling Smoke Detection System

The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features

FCS-320-TM Series Conventional Aspirating Smoke Detectors

ZXSe Range Data Sheet

Application Guide 001

Opal TM AV Devices. Data Sheet. Benefits

ID2000. intelligent fire alarm panel

HART XL High Sensitivity Smoke Detection

HART XL High Sensitivity Smoke Detection

ID50series. intelligent fire alarm panels

intelligent fire alarm ID60series panels

Aspirating Smoke Detection (ASD) Systems Fire Detection

Interface Modules for SENTRI

Opal TM AV Devices. Data Sheet. Benefits

Siemens aspirating smoke detector (ASD) for the addressed FDnet/C-NET detector line or for standalone operation

FDA241, FDA221 Siemens ASD

FAS-420 Aspirating Smoke Detector LSN "improved version" FAS-420. Operation Guide

Open-area Smoke Imaging Detection (OSID)

Open-area Smoke Imaging Detection (OSID)

Solution F2. Fire Alarm Control Panels one step ahead.

Extending Your Potential. Product Range

Open-area Smoke Imaging Detection (OSID)

E N G L I S H FIRE ALARM ASPIRATION SENSING TECHNOLOGY QUICK INSTALLATION GUIDE ADDRESSABLE FAAST LT MODELS MI-FL2011EI, MI-FL2012EI AND MI-FL2022EI

FCS-320-TM Aspirating Smoke Detector FCS-320-TM FCS-320-TM-R. Operation Guide

ID3000 intelligent. fire alarm panel

FAS-420-TM Aspirating Smoke Detector FAS-420-TM. Operation Guide

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

FAAST. Fire Alarm Aspirating Sensing Technology

The EN54 Part 2 and 4 Fire System

SUPREMATouch. Modular Fire & Gas Detection System

IMPORTANT. PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times!

ZX1e ZX2e ZX5e. Document No Issue 01 user manual

For Complete Fire and Gas Solutions

Open-area Smoke Imaging Detection (OSID)

CONVENTIONAL >FIRE DETECTION C400 SYSTEM FIRE DETECTION

TITLE SLIDE. FIRERAY2000 EExd OPTICAL BEAM SMOKE DETECTOR. Doc. No: Copyright Fire Fighting Enterprises Ltd.

Fire control panel detect 3004 plus and accessories

FDA241, FDA221 Siemens ASD

Flexible Air-sampling Smoke Detection

IQ8Control C Fire Alarm Panel

I N T E L L I G E N T A S P I R A T I N G. Intelligent Aspirating Fire Detector. Intelligent Earliest Warning Aspirating Fire Detector

Aspiration Systems for Smoke Detection

SUPREMATouch. Modular Fire & Gas Detection System

FAAST. Fire Alarm Aspirating Sensing Technology

ID3000 intelligent. fire alarm panel

ZXSe Range. Fire Safety. Analogue addressable fire alarm control panel KEY FEATURES. Panel Features

LASER ASPIRATED SMOKE DETECTOR

Air Sampling Smoke Detection System TITANUS MICRO SENS Rev.a

Why Hart XL Aspirating Smoke Detection?

Open-area Smoke Imaging Detector. Engineering Specification

The EN54 Part 2, 4 and 13 Fire System

INSTALLATION AND MAINTENANCE INSTRUCTIONS NFXI-BEAM AND NFXI-BEAM-T REFLECTED TYPE PROJECTED BEAM SMOKE DETECTOR

The new detector from Rafiki

THE ULTIMATE SOLUTION FOR GAS DETECTION SYSTEMS. DRÄGER REGARD

OH110, OP110, HI110 Automatic fire detectors

-Industrial. W hen All Else Fails... Difficult Applications. The Only TRULY Industrial Air Sampling Detector For Hostile and Difficult Environments

S200Plus Triple Infra Red Flame Detector Triple Waveband Infra-Red Flame Detection

EVC-P CONVENTIONAL PHOTOELECTRIC SMOKE DETECTOR. instruction manual. evolution EVC-P Conventional Photoelectric Smoke Detector

High-precision aspirating smoke detectors for every requirement SecuriRAS ASD 535, ASD 532 and ASD 531 aspirating smoke detectors

Analogue Addressable Fire Panel Range

MINERVA S200Plus. Fire Detection. Triple Waveband Infra-Red Flame Detection. Features: Minerva S200PLUS

Touchpoint Plus. A whole new control experience

Consultant Specification AGILE Wireless Fire Detection System

Reliably Advanced Extinguishing Control

Fireray Application and. Installation Guide FEATURES. Range metres. 12V to 24V dc operation. Selectable alarm thresholds

Intelligent Earliest Warning Aspirating Fire Detector

Reliably Advanced Extinguishing Control

Notifier by Honeywell: Non-Addressable Audible & Visual Alarm Devices. Approved to EN54-3/EN54-23

FIRERAY 5000 range USER GUIDE

SENSE Instruments CO., LTD. Data sheet Gas detector Page 1 / 5. Gas detector

The EN54 Part 2 & 4 Fire System

MINERVA MZX125 Digital Addressable Fire Detection System

Reflective Optical Beam Smoke Detector User Guide

Intellia Sounder Bases and Sounder Beacon Bases

LASER ASPIRATED SMOKE DETECTOR

High-precision aspirating smoke detectors for every requirement.

Sensepoint XCL Fixed Gas Detector

System 800 Addressable Fire Detection & Alarm System

Quick Selection Guide Fire Systems LSN Periphery

Why choose Fireray? Why use a Beam Smoke Detector? Product Range.

MINERVA MZX125. Digital Addressable Fire Detection System

MINERVA. Marine. Fire Detection. MX T2000 Panel Range. Features: MINERVA Marine Panel Range

Saving lives, protecting valuables, securing process cycles Fire detection

this is by far the best beam money can buy

Aspirating Systems. Ducts. System Sensor Design Guide

Tel: +44(0) Fax: +44(0) /17 LGM Products Ltd. Web: ISO 9001:2015 certified

Substation Monitoring System

FAAST. Fire Alarm Aspiration Sensing Technology

Motorised Infrared Optical Beam Smoke Detector. User Guide

Optical Smoke Detector Heat Detector Manual Call Point Output Unit Isolator

INSTALLATION AND MAINTENANCE INSTRUCTIONS TC866E Series LASER ASPIRATED SMOKE DETECTOR

IEC Functional Safety Assessment

MINERVA MX. 800 Series Ancillary Equipment

FAS 420 Series Aspirating Smoke Detectors LSN improved version

User manual. ABB i-bus EIB. Zone Terminal MT/S Intelligent Installation System ABB STOTZ-KONTAKT

Transcription:

Air Sampling Smoke Detection Notifier by Honeywell: Data Sheet

Air Sampling Smoke Detection Data Sheet The Notifier by Honeywell range of air sampling smoke detection systems (ASSD) comprises smoke detectors that actively take air samples from the monitored area and analyse them for the presence of smoke particles. This active sampling technology enables the identification of a possible fire in its very earliest stages from just 1 gram of material combustion. Features Early fire detection thanks to innovative, highly sensitive HPLS light source technology High degree of false immunity through LOGIC SENS fire pattern recognition Up to 3 thresholds for a tiered concept Optional smoke level display in bar graph form A broad range of accessories, approved to EN 54-20 High degree of modularity for a customised, cost effective solution Reliable project design with just 5 mouse clicks using PipeXpress planning software Time saving commissioning through Plug & Play Double-knock detection to enable separate room and equipment monitoring The ASD range The range comprises 3 detector units providing comprehensive solutions for a wide range of applications. HI-SPEC ASD HI-SPEC ASD serves a wide range of applications with the highest specifications. The system has a 3-stage system and a smoke level display in bar graph form. It provides a complete solution with smoke level visualisation for up to 560 m pipe length for monitoring large areas. ALL-SPEC ASD ALL-SPEC ASD is a universal air sampling device for a broad range of applications. The high degree of modularity of the device makes it possible to achieve a highly adaptable, costeffective solution. COMPACT ASD The COMPACT ASD air sampling smoke detection system is a cost-effective solution for monitoring small to mediumsized spaces and equipment. It is ideal for applications where larger air sampling smoke detection systems would not be cost-effective or in situations that require individual room identification. This document is not intended to be used for installation purposes. Every care has been taken in the preparation of this document but no liability can be accepted for the use of the information therein. Design features may be changed or amended without prior notice. For more information, contact: NOTIFIER. Charles Avenue, Burgess Hill, West Sussex, RH15 9UF. United Kingdom Phone: +44 (0) 1444 230 300 Fax: +44 (0) 1444 230 888 Page 1 of 5-990-158_0811 ISO9001 Design, Manufacture and Supply to Quality Management Systems Certified to ISO9001:1994

HI-SPEC1 ASD & HI-SPEC2 ASD HI-SPEC ASD was developed to serve a wide range of applications with the highest specifications. The system has a 3-stage system and a smoke level display in bar graph form. The HI-SPEC2 ASD enables the use of a second detector module. This means that one air sampling device can monitor two separate monitored areas. Alternatively, double-knock detection can be set up for both room and equipment monitoring purposes. The DIAG3 diagnostics tool enables quick and easy configuration and download of event log. The coverage of the detector is in accordance with EN 54-20: a single HI-SPEC2 ASD system can replace up to 64 point-type smoke detectors. Thanks to a powerful fan operating, a pipe length of up to 560 m can be achieved fulfilling EN 54-20 Class A to C requirement. Specifications HI-SPEC1 ASD & HI-SPEC2 ASD Mechanical specification HI-SPEC1 ASD HI-SPEC2 ASD Dimensions Width: 200 mm 200mm Height: 292 mm 292mm Depth: 113 mm 113mm Weight: 1460g 1560g Max. number of sampling holes 32 64 Max. pipe length (with max. number of sampling holes) 300 m 560 m Number of detector modules 1 2 Max Wire Gauge for Terminals: 1.5mm 2 1.5mm 2 Electrical specification Operating voltage: 24 V DC (14-30 V DC) Alarm and fault relay power rating 1 A, 30 V dc, max. 24 W Max. quiescent current (at 24 V DC)** 200 ma 230 ma Max. current (at 24 V DC)** 230 ma 290 ma Starting current limited to 300 ma 330mA General information Monitoring of pipe systems for breakage and obstruction. Optional adjustment for individual hole monitoring* Double-knock detection option Built-in event log, with additional external datastorge option using the DIAG3 diagnostics software Approved in accordance with EN 54-20, Classes A, B, C (manufacturer s certificate): VdS-No. G 206004 BPRI-No. 0786-CPD-20685 Monitored area per sampling hole corresponds to one point-type smoke detector in accordance with BS5839 & BS6266. Displays on device Pre- 1 red display per detector Main 1 red display per detector Info 1 red display per detector Smoke level 10 step bar graph display per detector Fault signal Yellow collective fault Operation Green operation display Detector sensitivity info pre main ASD-TT-05 1 0.17 0.3 0.5 ASD-TT-01 2 0.03 0.07 0.1 ASD-TT-001 3 0.005 0.010 0.015 Sensitivity measured as % LT/m (light obscuration per metre) Sampling holes in accordance with EN 54-20 Classes: 1 A max. 2x3, B max. 2x7 and C max. 2x15 2 A max. 2x9, B max. 2x32 and C max. 2x32 3 A max. 2x32, B max. 2x32 and C max. 2x32 Environmental specifications Temperature Range: -20 C to +60 C Humidity: 10 to 95% relative humidity (non-condensing) Ingress Protection IP20 Other products in the range HI-SPEC1 ASD & HI-SPEC2 ASD are also available in cold storage versions capable of operating in temperatures as low as -40 C or silent versions, which operates at noise levels as low as 23 db (A). Please contact us for full details. A comprehensive range of pipework system parts and accessories, along with PipeXpress project planning software, are also available from Notifier by Honeywell. * Depending on project design **at standard 6.9V fan voltage Page 2 of 5-990-158_0811

ALL-SPEC1 ASD & ALL-SPEC2 ASD ALL-SPEC ASD is a universal air sampling device for a broad range of applications. The high degree of modularity of the device makes it possible to achieve a highly adaptable, cost-effective solution. An additional price advantage comes with the optional equipping of the device with a second detector module. This means that one air sampling device can monitor two separate monitored areas. Alternatively, double-knock detection can be set up for both room and equipment monitoring purposes. The DIAG3 diagnostics tool enables quick and easy configuration and download of event log. The coverage of the detector is in accordance with EN 54-20: a single ALL-SPEC2 system can replace up to 64 point-type smoke detectors. Thanks to a powerful fan, a pipe length of up to 560m can be achieved fulfilling EN 54-20 Class A to C requirement. Specifications ALL-SPEC1 ASD & ALL-SPEC2 ASD Mechanical specification ALL-SPEC1 ASD ALL-SPEC2 ASD Dimensions Width: 200 mm 200mm Height: 292 mm 292mm Depth: 113 mm 113mm Weight: 1460g 1560g Max. number of sampling holes 32 64 Max. pipe length (with max. number of sampling holes) 300 m 560 m Number of detector modules 1 2 Max Wire Gauge for Terminals: 1.5mm 2 1.5mm 2 Electrical specification Operating voltage: 24 V DC (14-30 V DC) Alarm and fault relay power rating 1 A, 30 V DC, max. 24 W Max. quiescent current (at 24 V DC)** 200 ma 220 ma Max. current (at 24 V DC)** 210 ma 240 ma Starting current 300 ma 320mA General information Monitoring of pipe systems for breakage and obstruction. Optional adjustment for individual hole monitoring* Double-knock detection option Built-in event log, with additional external data storage option using the DIAG3 diagnostics software Approved in accordance with EN 54-20, Classes A, B, C (manufacturer s certificate): VdS-No. G 202064 BPRI-No. 0786-CPD-20685 Monitored area per sampling hole corresponds to one point-type smoke detector in accordance with BS5839 & BS6266. Displays on device Alarm 1 red display per detector module Fault Yellow collective fault Operation Green operation display Detector sensitivity ASD-TP-05 1 0.5 ASD-TP-01 2 0.1 ASD-TP-001 3 0.015 Sensitivity measured as % LT/m (light obscuration per metre) Sampling holes in accordance with EN 54-20 Classes: 1 A max. 2x3, B max. 2x7 and C max. 2x15 2 A max. 2x9, B max. 2x32 and C max. 2x32 3 A max. 2x32, B max. 2x32 and C max. 2x32 Environmental specifications Temperature Range: -20 C to +60 C Humidity: 10 to 95% relative humidity (non-condensing) Ingress Protection IP20 Other products in the range ALL-SPEC1 ASD & ALL-SPEC2 ASD are also available in cold storage versions capable of operating in temperatures as low as -40 C or silent versions, which operates at noise levels as low as 23 db (A). Please contact us for full details. A comprehensive range of pipework system parts and accessories, along with PipeXpress project planning software, are also available from Notifier by Honeywell. * Depending on project design ** at standard 6.9V fan voltage Page 3 of 5-990-158_0811

COMPACT ASD & COMPACT2 ASD The COMPACT ASD air sampling smoke detection system is a cost-effective solution for monitoring small to medium-sized spaces and equipment. The COMPACT2 ASD incorporates a room identification (ROOM IDENT) function enabling it to monitor up to 5 rooms or facilities and to identify the source of the potential fire. A COMPACT ASD system can be used to replace up to 8 point type smoke detectors. This requires up to 50 m of pipe length, regardless of whether Class A, B or C is required in accordance with EN 54-20. The COMPACT ASD is ideal for applications where larger air sampling smoke detection systems would not be cost-effective or in situations that require individual room identification. The DIAG3 diagnostics tool enables quick and easy configuration and download of event log. Specifications COMPACT ASD & COMPACT2 ASD Mechanical specification Dimensions Width: Height: Depth: 140 mm 222 mm 70 mm Weight: 850-895g* Max. number of sampling holes 8 Max. pipe length (with max. number of sampling holes) 50 m Max Wire Gauge for Terminals: 2.5mm 2 Electrical specification Operating voltage: 24 V DC (16-30 V DC) Alarm and fault relay power rating 1 A, 30 V DC, max. 24 W Max. quiescent current (at 24 V DC) 105 ma (at 9V standard fan voltage) Max. current (at 24 V DC) 110-140 ma (at 9V standard fan voltage) Starting current 150 ma General information Monitoring of pipe systems for breakage and obstruction. Optional adjustment for individual hole monitoring** Built-in event log, with additional external data storage option using the DIAG3 diagnostics software Detection Sensitivity Pre-: 0.25 % LT/m Main : 0.50 % LT/m Sensitivity measured as % LT/m (light obscuration per metre) Sampling holes in accordance with EN 54-20 Classes: A max. 2, B max. 6 and C max. 8 Approved in accordance with EN 54-20, Classes A, B, C (manufacturer s certificate): VdS-No. G 202064 BPRI-No. 0786-CPD-20322 Monitored area per sampling hole corresponds to one point-type smoke detector in accordance with BS5839 & BS6266. Displays on device COMPACT ASD Pre- and main Fault signal Operation COMPACT2 ASD Pre- and main Fault Operation ROOM IDENT indicators Environmental specifications Temperature Range: Humidity: Ingress Protection 1 red display for each stage Yellow common fault Green operation display 1 red display for each stage Yellow common fault Green operation display 5 red displays -20 C to +60 C 10 to 95% relative humidity (non-condensing) IP54 * Depending on device configuration ** Depending on system design Page 4 of 5-990-158_0811

Product Range at a Glance Sensitivity Part Number COMPACT ASD (including detector) 0.5% obscuration/m ASD-CM COMPACT2 ASD (including ROOM-IDENT functionality) 0.5% obscuration/m ASD-CM2 ALL-SPEC1 ASD ALL-SPEC1 ALL-SPEC2 ASD ALL-SPEC2 Smoke detectors for ALL-SPEC ASD 0.5% obscuration/m ASD-TP-05 0.1% obscuration/m ASD-TP-01 0.015% obscuration/m ASD-TP-001 HI-SPEC1 ASD HI-SPEC1 HI-SPEC2 ASD HI-SPEC2 Smoke detectors for HI-SPEC ASD 0.5% obscuration/m ASD-TT-05 0.1% obscuration/m ASD-TT-01 0.015% obscuration/m ASD-TT-001 Page 5 of 5-990-158_0811 Charles Avenue T: +44 (0) 1444 230 300 Burgess Hill F: +44 (0) 1273 376 894 W. Sussex E: sales@notifierfiresystems.co.uk RH15 9UF