scorpion SMOKE TESTING FOR ASD SYSTEMS AND HARD-TO-ACCESS POINT DETECTORS IN ACADEMIA APPLICATIONS RESTRICTED AREA AUTHORISED ENTRY ONLY

Similar documents
solo detectortesters single testing system. complete range of testing tools. testing technology from No Climb

scorpion User Manual Remote Tester for Point Smoke Detectors & Aspirating Smoke Detection (ASD) Systems

testifire Quick Start Guide MULTI-STIMULUS DETECTOR TESTER Multi-Detector Test Apparatus as to Verification of Detector Functional Operation Only 77TL

User Manual.

USER MANUAL 1000 SERIES.

Using Height Access Poles for Safe Testing Of Fire Detection Systems

solo detectortesters single testing system. complete range of testing tools. detectortesters testing technology from No Climb

SMOKE DETECTOR TESTERS

Push Button Electronic Timer. 31VETR Series. Installation Instructions

SAQCC FIRE D&GS TRAINING SUB COMMITTEE COURSE CURRICULUM

Test units and accessories

Motor Solo Run. Power cable energized (2 hours)

SUNWARM AIR SOLAR PRE-HEAT VENTILATION SYSTEM

HART XL High Sensitivity Smoke Detection

User s Guide HHAQ-109. Portable Multi-gas Detector. Shop online at omega.com SM

English. Instruction and operation manual S 530. Leak detector for pneumatic systems

English. Instruction and operation manual S 530. Leak detector for pneumatic systems

Aspirating Systems. Ducts. System Sensor Design Guide

Aspirating Detection System. Protec Aspirating Detection System Lift Shaft Design Guide. MED2198 Lift Shaft Design Guide Issue 0 Page 1 of 23

Push Button Electronic Timer. 31VETR3 Series. Installation Instructions

Gambling with your fire security?

Installation and user manual for the BiWire / Conventional Repeater Panel

Project Briefing Document. Section 3 Electrical Services design guide and specifications

Aspirating Detection System. Protec Aspirating Detection System Atria Design Guide. MED2199 Atria Design Guide Issue 0 Page 1 of 22

HART XL High Sensitivity Smoke Detection

PAD100-6DB & PAD100-4DB PAD100-PD

Ceiling-Mounted Motion Detector. 752/CD, 752/CP, 752/CU and 752/Cx180. Installation Instructions

FIRE ALARM CONTROL PANEL FVC01-08

Guidance Note. Guidance Document on Best Practice for Fire Detector Testing/Test Equipment

SprintIR -W CO2 Sensor

Conventional Fire System. BiWire Flexi Fire Panel EFBW8ZONE-FLEXI / EFBW4ZONE-FLEXI / EFBW2ZONEFLEXI User Manual

PROFYRE C8 USER MANUAL, MAINTENANCE GUIDE & LOG BOOK FIRE ALARM CONTROL PANEL USER MANUAL, MAINTENANCE GUIDE & LOG BOOK

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

Siemens aspirating smoke detector (ASD) for the addressed FDnet/C-NET detector line or for standalone operation

USER MANUAL, MAINTENANCE GUIDE & LOG BOOK

Installation, Operating and Maintenance Manual

Code of Practice for the Management of Overhead Corridor Ducts in the Main Building.

High-precision aspirating smoke detectors for every requirement SecuriRAS ASD 535, ASD 532 and ASD 531 aspirating smoke detectors

FirePro ANNEX 1 MARINE MANUAL. Version 1,

Aspirating Smoke Detection (ASD) Systems Fire Detection

CAREL CONTROLLER. Programming Instructions HOW TO CHANGE LEVEL 1 CONTROL SETTINGS HOW TO CHANGE LEVEL 2 CONTROL SETTINGS

Developments in Australian Standard AS (Emergency Lighting)

Buys Time. Aspirating Smoke Detection

Fire detection and alarm

SENSELEC INFRA-RED CONTROLS

LMV51 Control. Specifications. Document No. LV February 7, Product Description. Sample Specification

Natural Ventilation. e-stack A-Series Ventilation System for Buildings with Atria. Installation and Maintenance. Palletised

ZC450-IB-09/13-01 US. Instruction Booklet. Zonecheck 450

Riva Studio Dedicated Sealed External Air Kit

USER MANUAL CEF AP28 CONTROL PANEL

Castle SONUS GA216I Combined Integrating Sound Level Meter

CORE Protection Fire System Specification

Installation Manual. Detector Bases: PAD100-IB, PAD100-RB & PAD100-SB

Introduction to Docking Technology

ZX1e ZX2e ZX5e. Document No Issue 01 user manual

Model 5190-F Temperature/Humidity Probe

Design Manual Installation Operation Maintenance

USER MANUAL, MAINTENANCE GUIDE & LOG BOOK

Model 5190-E Temperature/Humidity Probe

G-TECTA Cellaguard Carbon Dioxide and Oxygen Fixed Monitors

Safe Operation Manual. Honeywell IQ Force Gas Detector

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

Robotic Vacuum. Operation Manual P4900

Serenity Series Auto Sensing Everything Bathroom Fan

USER MANUAL, MAINTENANCE GUIDE & LOG BOOK

Ingersoll Rand. Refrigerated Air Dryers

Checklist For Building Inspection & Fire Safety

FIREMASTER CONCERTINA TM

An Overview of Extinguishing Systems for Computer Equipment

Description FEATURES. l Innovative dual mount system requires only one sensor for either flush or surface mount applications

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

AVAILABLE TO DOWNLOAD ON THE APOLLO APP. Pocket guide to. Fire Alarm Systems Design BS Standard

Control Panel User Guide

USER MANUAL, MAINTENANCE GUIDE & LOG BOOK

LASER ASPIRATED SMOKE DETECTOR

SPECTRA 1727 USER S GUIDE

Thermometer with Probe model 00891A

Duct Mount. Installation Instructions

A Steam-e product All Rights Reserved. STEAM CLEANER Operating Instructions - June 2018

Touch Screen 1 loop Addressable Fire Alarm Panel

Electrostatic Precipitator

A GUIDE TO FIRE DETECTION AND ALARM SYSTEMS

Preface. Overview. The above illustration shows a typical three zone Aprilaire Zoned Comfort Control system.

LASER ASPIRATED SMOKE DETECTOR

Signalpoint. The Signalpoint range of flammable, toxic and Oxygen gas detectors offer users a low cost solution to their indoor gas monitoring needs

FIREMASTER ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES LEADING THE WAY IN FIRE PROTECTION

Buys Time. Aspirating Smoke Detection

Conventional Fire Detection

this is by far the best beam money can buy

Fire Systems Design Pocket Guide BS 5839 Part 1:2017 and CoP 0001 for Visual Alarm Devices. Fire Installers Mate. A guide to fire system design

Pre-Pack INTEGRATED PRE-ACTION SYSTEM

The World s No. 1 Brand of Aspirating Smoke Detection

FIRE ALARM SOLUTIONS THAT FIT YOUR NEEDS

HERSCHEL SUMMIT 2600 HERSCHEL SUMMIT 2600R Ceiling or Wall-mounted Infrared Heaters

High-precision aspirating smoke detectors for every requirement.

Measurement Solutions for Refrigeration Technology.

Xenex Conventional Fire Detection & Alarm System

K Series - Fire Suppression Systems for the Catering Industry

The World's No. 1 Brand of Air-sampling Smoke Detector

Transcription:

SMOKE TESTING FOR ASD SYSTEMS AND HARD-TO-ACCESS POINT DETECTORS IN ACADEMIA APPLICATIONS scorpion www.scorpion-tester.com

HARD-TO-ACCESS SMOKE DETECTORS IN A TYPICAL UNIVERSITY Atria and Concourses Testing smoke detectors can be undertaken without disruption at any time of the day and in a safe manner. Lecture Theatres These areas are often in constant use throughout the day and testing the detectors would cause disruption. Food Halls These areas often have detectors above a suspended ceilings. Data Centres This includes any room that has restricted access, or is locked for security. Plant and High Voltage Transformer Rooms Routine smoke detector testing can be carried out without having to enter the facility. Lift Shafts, stairwells, and Risers Smoke detection is tested at lower risk, without 3rd-party engineers or access equipment, and leaves the lift operational for those with accessibility needs and stairwells available as alternative access. Voids, Service and Ventilation Ducts These areas and above acoustic tiles or behind ceilings, are all tested safely from ground level. Sports Halls, Workshops and Service Areas These often have high ceilings with detectors protected by cages to prevent damage. Archives and Storage Including any room that has restricted access, or is locked for security. WHEN DO YOU NEED SCORPION? Scorpion is a unique test solution that solves a problem that has never before been tackled. There are many reasons for installing Scorpion including: 1. 2. 3. 4. 5. 6. When you need to be sure ALL detectors are tested When access to the detector for testing is costly and/or difficult When Health and Safety risk assessments are slowing you down When you want an innovative, professional, and fit for purpose test solution When accuracy is key When compliance with standards and maintenance schedules is as important as cost efficiency

HOW CAN I TEST HARD-TO-ACCESS DETECTORS EFFICIENTLY? Scorpion is an innovative solution for functionally testing any hard-to-access smoke detector, whether that is a point detector or aspirating smoke detection (ASD) system. A Scorpion head unit is a smoke generator which is installed next to a detector, and when required, generates smoke which is directed towards the detector for a functional test of the device. Scorpion makes testing detectors in atria, lecture theatres, lift shafts, secure areas, archives, and sports halls as easy as testing a detector within easy reach. HOW DOES IT WORK? AUTHORIZED PERSONNEL ONLY By introducing smoke right where it is needed, Scorpion is able to activate point detectors or ASD systems with minimal inconvenience. Scorpion is a micro smoke generator permanently installed adjacent to a point detector or a sampling hole on an ASD pipe typically at the furthest sampling hole. The smoke generator is connected to a Scorpion Control Panel, or Access Point mounted at a convenient, easy to access location at ground level. Functional testing of the smoke detector is then easily and safely achieved from the Scorpion Control Panel, or Access Point (with an Engineer s Controller) whenever required. The Scorpion system has an in-built transport timer to help assess the on-going integrity of the ASD system from the end of the pipe right down to the detector itself. A clearing function is used to clear the smoke out of point detectors to reduce the chance of repeat alarms, increasing productivity on site. SCORPION can be used on new fire systems as well as being retro-fitted to existing systems Scorpion can be retro-fitted to existing systems or be installed with new systems. Each head unit has a test capability in excess of 240 tests of 15 seconds of smoke each. HOW IS TESTING DIFFERENT TO MAINTENANCE? Aspirating Smoke Detector (ASD) solutions are sometimes described as low maintenance or easy to maintain. While this is true of the detector panel which is in a location that is easily accessible, the same cannot be said of the sampling pipe used to detect the smoke which extends into the protected area, and very often is not easily accessible. Maintenance of the system includes cleaning the sampling pipe by blowing compressed air through it, and assumes that this will clear the dust and debris out of the sampling holes. It also assumes that the pipe itself is intact along its whole length. Electronic systems in the panel give alarms for airflow errors if holes get blocked or if the pipe breaks, but can be manually over-ridden. Testing that the system works can only be done by ensuring that real smoke, when introduced at the furthest sampling hole, will be drawn along the length of the pipe and show an alarm on the detector. With Scorpion, the Transport Time measured using this test can be compared with design and commissioning data to ensure that the system continues to deliver the necessary protection. Testing using Scorpion proves that the maintenance carried out has been effective. Break in the ASD sampling pipe. Panel was re-programmed and so did not display any faults.

THE IMPORTANCE OF COMPLIANCE TIME SAVING BENEFITS All detectors, regardless of location, should be tested and maintained in compliance with international codes and standards. Installing Scorpion supports this and eliminates the need for deviations from such standard - offering ultimate peace of mind and proof that all detectors within a building are functioning as expected. Installing Scorpion dramatically reduces the time taken to test hard-to-access detectors. Scorpion allows these detectors to be tested easily as part of the routine test during the engineer's visit - without the need for a return visit out of hours and without the time taken to directly access the detector. COST SAVING BENEFITS Detectors in hard to access locations are often costly to test and maintain. They require specialist access equipment, potentially the presence of a third party company and often more than one engineer. All of which takes time as well as money to arrange. Existing process without Scorpion Year 1 with Scorpion install Fire Maintenance Scorpion Installation Organisation, Risk Assessments, Disruption etc. Access* Fire Maintenance Engineer Organisation, Risk Assessments, Disruption etc. Access* Fire Maintenance Engineer Time & Cost Example of typical cost and time savings using Scorpion Year 2 onwards *Access costs may include equipment or a service engineer (in the case of a lift installation). SCORPION INSTALLATION EXAMPLES Scorpion on an ASD system where the end sampling hole is located within a locked cage. Scorpion on a Point Smoke Detector in the void above a suspended ceiling.

Scorpion can, in theory, be installed alongside any point smoke detector or aspirating system. However, you will appreciate the benefits of the product more if you have detectors in areas such as the following: Lecture Theatres, Atria, Concourses, and Sports Halls - No access equipment necessary e.g. cherry pickers, scissor lifts - Health and safety issues avoided - No disruption to students or staff Configuring your Scorpion solution is simple: 1) Select the Head Unit: Are you testing ASD systems or Point Detectors? SCORP 2001-001 2) Select how the Head Unit/s will be controlled: CONTROLLER OPTIONS Data Centres, Plant Rooms, Substations SCORP 1001-001 Scorpion ASD Head Unit Lift shafts and stairwells - Eliminates disruption - Lifts remain available for use during testing - No third party company required e.g. lift engineer - No requirement for out of hours working - Quicker test period - No deviations from test standards Scorpion Point Head Unit HEAD UNITS WHAT APPLICATIONS CAN IT BENEFIT? - Smoke detectors are tested from outside the secure area 1-4 Head Units 5-8 Head Units (1 Access Point per Head Unit within 100m radius) (within 100m radius) Scorpion Access Point Scorpion Engineers Portable Controller Scorpion Wall Mounted Control Panel SCORP 25-001 SCORP 7000-001 SCORP 8000-001 3) Select your Solo Battery Baton and Charger: - Avoids problems related to access to confined spaces - Potential damage to building infrastructure avoided - Quicker test period - Eliminates disruption - No deviations from test standards Hazardous or Inaccessible areas - Avoids health and safety risks POWER Void Spaces and Service Ducts Solo Battery Baton Solo Universal Fast Battery Charger SOLO 760-001 SOLO 726-001 Note: these are used for all Detectortesters products Solo, Testifire and Scorpion. - No need for risk assessments scorpion

Extending a Scorpion System A Scorpion system can be extended by adding additional Head Units (Point or ASD). These are available to suit the selected Controller (Wall Mounted or Portable). Optional Point Head Unit Kits Scorpion Point Head Unit Kit* (for use with SCORP 8000 Wall Mounted Controller) SCORP 1001-001 Optional ASD Head Unit Kits Scorpion Point Head Unit Kit* - (for use with SCORP 7000 Portable Controller) SCORP 1011-001 Scorpion ASD Head Unit Kit (for use with SCORP 8000 Wall Mounted Controller) SCORP 2001-001 Scorpion ASD Head Unit Kit - (for use with SCORP 7000 Portable Controller) SCORP 2011-001 *Detector not incuded Technical Specifications Environment Transport / Storage Temperature Storage Humidity Operating Temperature Operating Humidity Ingress Protection Weights and Dimensions Scorpion Head Unit Scorpion Control Panel Scorpion Engineer s Controller -10 C to 70 C (14 F to 158 F) -10 C to 50 C (14 F to 122 F) -10 C to 50 C (14 F to 122 F) 0-90% RH 0-90% RH 0-90% RH 0 C to 60 C (32 F to 140 F) 5 C to 45 C (41 F to 113 F) 5 C to 45 C (41 F to 113 F) 0-95% RH 0-85% RH 0-85% RH IP20 <200g 155mm (L) x 54mm (W) x 34mm (H) (excluding nozzle) IP40 <500g 150mm (L) 155mm (W) x 37mm (H) IP20 <500g 220mm (L) 95mm (W) x 40mm (H) (excluding cables) Note: The Scorpion system is designed for specific applications within the above parameters. For additional information regarding location and installation procedures, please refer to the Scorpion User Manual at: www.scorpion-tester.com Safety features Scorpions energized only at time of test Isolation between Scorpion circuit and detection system Internal over-current protection on Scorpion circuit Battery over-current cut-out Power source and charge data Solo Battery Baton (Solo 760-001) or Battery Pack (SCORP 50) - nominal 7.2v 2.2Ah, NiMH rechargeable Charge time 60-90 minutes (when completely discharged) using a Solo 726-001 charger scorpion Tel: +44 (0) 1707 282 760 Fax: +44 (0) 1707 282 777 info@detectortesters.com www.detectortesters.com 2 2 As our policy is one of continuous improvement, details of products described within this publication are subject to change without notice. All information provided here is believed to be correct at the time of going to press. Every effort has been made to ensure the accuracy of information which is provided in good faith but nothing contained herein is intended to incorporate any representation or warranty, either express or implied or to form the basis of any legal relations between the parties hereto, additional to or in lieu of such as may be applicable to a contract of sale or purchase. This information must be read in conjunction with the Scorpion Installation Manual & User Guide which provides further information on Scorpion applications, compatibility and suitability. No Climb Products Ltd Edison House 163 Dixons Hill Road Welham Green Hertfordshire AL9 7JE United Kingdom Cabling Scorpion circuit wiring: FP200 1.5 mm, Lapp J-Y(ST) Y 0.5 mm, or equivalent - 3 cores per Head Unit Maximum cable length per Scorpion Control Panel 100 metres (depending on cable used) 8 Scorpions (max.) per Control Panel 1 Scorpion per Access Point International Patents Apply Scorpion is a registered trademark. detectortesters testing technology from No Climb www.scorpion-tester.com LIT1144-1