Fire Systems Maintenance and Fire Detection Systems. Dwayne Smith Fire Protection Engineer

Similar documents
2004 AUSTRALIAN STANDARDS UPDATE

FIRE AND EVACUATION PLAN

2. The Group F occupancy has have an a combined occupant load of 500 or more above or below the lowest level of exit discharge.

Building Consent Application Compliance Schedule Information

4 August Islington Fire Protection Transpower NZ Limited

AS Fire detection, warning, control and intercom systems System design, installation and commissioning. Presented by: DAVID ISAAC

SAQCC FIRE D&GS TRAINING SUB COMMITTEE COURSE CURRICULUM

Certification Assessment Instrument and Guidelines

Baseline Data Required for AS

SCHEDULE. Essential Safety Measures taken from Schedule 9 of the Building Regulations PART 1 BUILDING FIRE INTEGRITY

St. Vincent s Health System Page 1 of 6

12/14/2013. Fire alarm and emergency power SPRINKLER HEAD

British Columbia Building Code 2006 Division B Part 3 Fire Protection, Occupant Safety and Accessibility Section 3.2 Building Fire Safety

Detection, and Suppression Systems

BUILDING CODE ACCESS CONSULTING ESSENTIAL SERVICES

Smoke Alarm User s Manual

Scope of Section 2. AS vs. Application Issues. Schedules & Log- Contents. Books

Approved Document for New Zealand Building Code Warning Systems Clause F7 Third Edition

Fire safety procedure

FIRE SAFETY POLICY Page 1 of 15 Reviewed: October 2017

NFPA 101 Code Update from 2012 Edition to the 2015 Edition

Firefighting operations on fire control centres F5-09 GD

FIRE DEPARTMENT - RULES FOR FIRE PROTECTION IN AUSTRIA

Firefighting operations on fire alarm panels F5-04 GD

2012 OBC Changes. Summary of key changes to Life Safety and Fire Protection Systems for CFAA January 22, 2014

Code of Practice for the Management of Overhead Corridor Ducts in the Main Building.

Innovative protection that combines power and flexibility

Draft FPA Australia Technical Specification for Public Comment FPAA101H DRAFT

Maintenance of Fire Systems

Purpose of Emergency Response Program Emergency Response Team / Leader Evacuation Procedures Building Life Safety System Virtual Evacuation Building

Workplace Guidelines

FIRE SAFETY MAINTENANCE INFORMATION for Agricultural Livestock Structures

Compliance Document for New Zealand Building Code Clause F7 Warning Systems Third edition

HART XL High Sensitivity Smoke Detection

Releasing Systems. Rob Mennie Senior Consultant Gage-Babcock & Associates Ltd.

University of London

MAINTENANCE OF ESSENTIAL SAFETY MEASURES EXPLAINED (Building Regulations 2006)

p. vi, References p. v, Contents p. 7, References pp. 7-8, References p. 5, Contents p. 7, References p. 9, Definitions p. 13, 1.2.

Advanced Fire Alarm Systems Training Program Outline (5 Day)

Martin Huber 26September 2017 F&G SOLUTIONS FOR THE PROCESS INDUSTRY

Australian Standard. Fire detection, warning, control and intercom systems System design, installation and commissioning. Part 1: Fire AS 1670.

POLICY. Code Announcement means an announcement (e.g. page or strobe light, verbal notification) to commence a Fire Drill without an audible alarm.

Loss Prevention Standards

Following are the systems proposed as per NBC & Local Fire Authority:

Scope. Warning sounders except specific requirements. Intercom Systems for Emergency Purposes. Sound Systems for Emergency Purposes

FIRE SAFETY 2013 ANNUAL REPORT. Author: Senior Fire Safety Advisor Contact Details for further information: Frank Barrett

FIRE PLAN. In order to assure the safety of patients, visitors and staff, a standard response to fire or the potential of fire is required.

SECTION 907 FIRE ALARM AND DETECTION SYSTEMS

CURTIN UNIVERSITY PROJECT DELIVERY GUIDELINES

Safety Engineering. Fire Protection Systems and Life Safety Systems

Element Z General Design Requirements Existing Facilities Information

NFPA 72 Code Changes vs 2013

Sprinkler Permit Applications

Establishing the Risk Basis of Building Size Limits

Unwanted Fire Alarms. Marty Ahrens National Fire Protection Association 1 Batterymarch Park Quincy, MA (617)

SURREY FIRE SERVICE. Construction Fire Safety Plan Bulletin

EC 5.10 FIRE PREVENTION MANAGEMENT

REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT

Client Advisory Note June 2015:

3.1 Introduction. 3.1 Introduction

Element Z General Design Requirements Existing Facilities Information

Other EC and LS documents may be requested by surveyors, as needed, throughout the survey.

highline SVCS-1 INSTALLATION & USER MANUAL SMOKE VENT CONTROL SYSTEM * enclosure design may vary software version: SVCS1r6 SVCS1r7 SVCS1r10

AVAILABLE TO DOWNLOAD ON THE APOLLO APP. Pocket guide to. Fire Alarm Systems Design BS Standard

Conventional Fire System. BiWire Flexi Fire Panel EFBW8ZONE-FLEXI / EFBW4ZONE-FLEXI / EFBW2ZONEFLEXI User Manual

Plan Review Check List Fire Alarm System

technical specification smoke venting systems

Firefighting operations on automatic sprinklers systems F5-06 GD

EN54 Part 23 Made Easy CPD PRESENTED BY SIMON ADAMS GENT BY HONEYWELL

MX4428. Addressable Fire Alarm System. Features. Advantages & Options

Terminal & Building Emergency Evacuation Induction

Fire Protection System and Life Safety Evaluation of Building X. Anthony W. Sublett

AS 2419 OVERVIEW OF PROPOSED CHANGES. Gary Nenadovich Director G N Consulting

Life Safety Code NFPA 10 NFPA 13 NFPA 25 NFPA 72 NFPA 90A NFPA 110 NFPA 99 THE 2012 EDITION OF THE LIFE SAFETY CODE HOSPITAL EDITION SESSION #7

COURSE SYLLABUS FIRE ALARM AND FIRE SUPPRESSION SYSTEMS CORRESPONDENCE COURSE

HIGH-RISE RETROFIT ORDINANCES - NO and NO

Fire Risk Assessment

Fire Risk Assessment

NFPA Changes

FIRE ALARMS EMERGENCY LIGHTS NURSE CALL ACCESS CONTROL GK FIRE & SECURITY LTD, UNIT 1 GREBE RD, PRIORSWOOD IND EST, TAUNTON, TA2 8PZ

RMS-I-DE-01 Smoke Detector

Smoke Alarm User Manual

Second Revision No. 104-NFPA [ Section No ] Submitter Information Verification. Committee Statement

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT HORSEFAIR HOUSE

Fire safety systems. Behaviour of fires

False Alarm Management. Graham Simons FIA Technical Manager

Winnipeg Fire Department Fire Prevention Branch

Practice Advisory 18: Fire safety design for tall buildings

Fire Safety Policy & Fire Safety Management System Version October 2013 Emergency Evacuation Procedures

2012 International Building Code Errata (Portions of text and tables not shown are unaffected by the errata)

Black Diamond Fire Department Building Owner s Responsibilities for Fire Safety Equipment

Draft FPA Australia Technical Specification for Public Comment FPAA101D DRAFT

KING S HOUSE SCHOOL FIRE RISK MANAGEMENT POLICY & PROCEDURES

IMC Significant Changes Summary Tier I

HART XL High Sensitivity Smoke Detection

Hi, welcome to the topic on Fire Detection and Alarm Systems. This topic forms one of the critical knowledge areas for prospective fire safety

Clofield Limited. Product Data Sheets. Paging System. Care Call. Preventative monitoring for homecare... Wireless alerting system for Carers

and Aspirating Smoke Detection

Some information I have read tells me to evacuate immediately in case of fire. Fire In Your Residential Building. To Go?? To Stay??

Chapter 5. Energy Conservation & Fire Safety

Transcription:

Fire Systems Maintenance and Fire Detection Systems Dwayne Smith Fire Protection Engineer

Introduction Overview of Regulatory Framework Act, Regulations and Codes Fire Protection Maintenance AS1851-2012 Tips and Tricks for maintenance FAQ Fire Detection System Design AS1670-2004 Unwanted alarm mitigation EWIS and Evacuation strategies

AS1851-2012 Current revision released in December 2012

Regulatory Framework QLD Building Act QLD Building Regulations QLD Development Code National Construction Code Series (BCA) Design Standards (e.g AS1670) Maintenance Standards - AS1851

Obligations Not required to comply with current design standards. Installation standards apply. Required to comply with the current maintenance standards.

Critical Defect? AS1851 now defines the level of a defect

Test Frequencies

Interface Testing Historically not captured very well, and in some cases not established at all Requires the testing of the interfaces between services, i.e smoke exhaust, stair press etc. Not intended as a commissioning test or retest.

Hospital Interface Testing Application of interface testing in a hospital can involve a significant number of services. Mechanical (stair press, smoke exhaust) Door releases Make up air Security BMS Public Address Gas shut off solenoids Pneumatic Tube

Testing Regimes It is often difficult to find records of testing other than weekly or monthly. 6 monthly, annual or more are rare. Instances in the past of significant sites in QLD with hydrant pipework which had not been hydrostatically or boost tested for 30 years. (5 yearly requirement). Another instance of a building which had a sprinkler system with no water in it for around 50 years. Annual testing would have picked this up.

Common Failures Underground pipework can deteriorate over time. Type B copper and Firelite were popular in the 1980 s, may not meet current requirements. Depending on water hardness, pipework may calcify an internal build up of calcium restricting flow. Water authorities are turning down water pressures in street mains to conserve water. From this, some systems no longer meet their requirements.

Internal conditions

Tips Consider an investigation into the underground pipework quality, and have it tested. Note, it may contain asbestos! Make sure you have a good clear block plan for sprinklers, detection and hydrants. Make sure that everything is labelled and corresponds with the block plan. Consider access safety to maintenance staff and QFRS is applicable, even though AS1851 doesn t mention it. Consider ESD initiatives hydrant and sprinkler test water can be captured and reused on site While we would recommend compliance with current standards, don t feel pressured into spending big money if you don t need to.

AS1670 Standard for fire detection and alarm systems (or is it?) AS1668, the standard for smoke control also applies. In hospitals, AS1670.4 (EWIS) is applicable as well. National Construction Code series drives the requirements for AS1670 detection.

National Construction Code Class 9a hospitals require full smoke detection to AS1670 regardless of height or size. The rise in storeys of a building drives the AS1668 fan control requirements. As an aside, sprinklers are required in any building greater than 25m in effective height, and may be provided in lieu of zone smoke control in a building with a rise in storeys of 3 or more. A full Emergency Warning and Intercommunication System (EWIS) is required for any hospital over 2 storeys or a floor area of more than 1000m 2

Detector Types Typical hospital detection types: Smoke Photoelectric or Ionisation type Heat fixed temperature or rate of rise Aspirated (Vesda) for critical areas such as server rooms, or where access is limited Fire Sprinklers Other detection devices covered by AS1670: Infrared Beam detection Linear Heat detection cable Other detection? Video smoke detection

System Types Two main types Addressable or Conventional In addressable systems, each detector has a unique address where it can be pinpointed by the FIP In conventional systems detectors are grouped into zones, identifies on the FIP as a zone rather than a detector. Conventional is generally being replaced with addressable.

General Intent of AS1670 Fire detection throughout the building every room, switchboards, lift shafts, risers. Additional fire detection is required in air handling units, stair press fans and the like Alarm tones are to be audible throughout

Specific Case Operating Theatre No special requirements under AS1670. A situation occurred in a hospital in New Zealand where a fire occurred in a plant room serving the theatre. Smoke was picked up by the Air Conditioning and dumped on top of the patient. As the smoke was cooled by the air, it didnt set off any detection in the room. There was no detection in the ventilation system. Patient had to be relocated mid operation once a manual alarm was raised.

Unwanted Alarm Mitigation Unwanted alarms are a nuisance to both the occupants and the fire brigade it ties up valuable resources. Smoke detectors can be triggered by dust, steam, or even invisible products of combustion. Areas in which false alarms are predicted (e.g kitchens) another detection device can be used instead of smoke detection usually a heat detector. The NCC considers a sprinkler to be the equivalent of a heat detector as they operate the same. In areas outside of patient care, it is possible to just delete a smoke detector altogether but note you lose the addressability function.

Emergency Warning and Intercommunication Systems Evacuation strategies in hospitals are a top priority due to the difficulty of mobilising patients. An EWIS allows full customisation of the system to maximise occupant discharge. This can be arranged such that alert and evacuate tones cascade radially occupants in the adjacent compartment are preparing to evacuate while the compartment of fire origin is evacuating. Warden intercommunication points, strobe lights, mimic panels and break glass alarms are also provided. Additional flexibility is afforded in the NCC for a reduction in alarm tone sound levels to suit the trauma of the patients.

Evacuation Strategy - Ipswich

Summary AS1670 drives the locations of detection and spacing requirements for full coverage. All of the building must be protected. Determines the requirements for detection type NCC permits the substitution of detectors to mitigate unwanted alarms AS1670.4 drives system requirements for a full EWIS to allow for orderly evacuation.