Conventional Detectors

Similar documents
Analogue Detectors. Series 200 plus

Beam Detectors. The 6500 Series

FAAST. Fire Alarm Aspiration Sensing Technology

Corporate Expertise. From the global experts in quality, technology and total cost of ownership of fire detectors.

Aspirating Systems. Ducts. System Sensor Design Guide

EC TYPE EXAMINATION (Module B) CERTIFICATE MARINE EQUIPMENT DIRECTIVE Certificate No.: 0832-MED-1019

S TEM PRODUCT SPECIFICATION

ID50series. intelligent fire alarm panels

Touch Screen 1 loop Addressable Fire Alarm Panel

TrueAlarm Smoke Detectors

The new detector from Rafiki

Quick Selection Guide Analog Addressable Fire Systems

MODEL 6200 ANALOGUE ADDRESSABLE OPTICAL BEAM SMOKE DETECTOR

Cerberus FIT conventional system

E N G L I S H FIRE ALARM ASPIRATION SENSING TECHNOLOGY QUICK INSTALLATION GUIDE STAND-ALONE FAAST LT MODELS FL0111E FL0112E FL0122E. 367 mm.

Carbon Monoxide (CO) Detection PRODUCTS. Accessories Conventional Detectors

optical detector multisensor detector heat detector mounting bases product guide

FAAST. Fire Alarm Aspirating Sensing Technology

FAAST PRODUCT RANGE Aspirating Smoke Detection

intelligent fire alarm ID60series panels

Polycarbonate External Sounder & Strobe Unit

FAAST. Fire Alarm Aspirating Sensing Technology

Laser Technology Smoke Detector

TX7100. Intelligent Addressable Optical Smoke Detector Installation and Operation Manual. TANDA UK Technology Copyright 2015, All right reserved.

INTRODUCING SOTERIA, POWERED BY COREPROTOCOL APOLLO'S MOST ADVANCED FIRE DETECTION SYSTEM

Optical Smoke Detector Heat Detector Manual Call Point Output Unit Isolator

HART XL High Sensitivity Smoke Detection

Intelligent addressable fire alarm control panel

RANGEOVERVIEW Integrated Emergency Lighting & Fire Detection System

PANELS, KEYPADS & MODULES. Take Fire Protection to the Next Level Fire Products from DSC

Addressable Detectors & Bases

Detection and Control Components

Intelligent 2 & 4 Loop Fire Alarm Control Panels

Intelligent Single Loop Fire Alarm Control Panel

Series 65 Product Guide MAN 3036

S200Plus Triple Infra Red Flame Detector Triple Waveband Infra-Red Flame Detection

TX7110. Intelligent Heat Detector Installation and Operation Manual. TANDA UK Technology Copyright 2015, All right reserved.

Notifier by Honeywell: SMART Detection. SMART Detection. The Ultimate in False Alarm Technology...Make the SMART choice

intelligent solutions

MINERVA S200Plus. Fire Detection. Triple Waveband Infra-Red Flame Detection. Features: Minerva S200PLUS

Intrusion Outdoor Protection Perimeter

Synchronous Detector

Photo Beam 5000/3000 Series Heater. en Installation Guide

Open-area Smoke Imaging Detection (OSID)

Aspir A ation spir P R O D U C T S

INTELLIGENT FIRE TECHNOLOGY. Twinflex and Multipoint V3. User Guide (TO BE RETAINED BY USER) Issue 3

INSTALLATION AND MAINTENANCE INSTRUCTIONS 6500R AND 6500RS REFLECTIVE TYPE PROJECTED BEAM SMOKE DETECTOR

Overview. Wireless Overview QLD NSW VIC Fundamentals. Operation. Features.

E N G L I S H FIRE ALARM ASPIRATION SENSING TECHNOLOGY QUICK INSTALLATION GUIDE ADDRESSABLE FAAST LT MODELS MI-FL2011EI, MI-FL2012EI AND MI-FL2022EI

All by design. ASSA ABLOY Door Controls

200 SERIES ADVANCED PHOTO/THERMAL/IR DETECTOR PRODUCT SPECIFICATION

Solution F2. Fire Alarm Control Panels one step ahead.

Flexible Air-sampling Smoke Detection

EVC-P CONVENTIONAL PHOTOELECTRIC SMOKE DETECTOR. instruction manual. evolution EVC-P Conventional Photoelectric Smoke Detector

Consultant Specification AGILE Wireless Fire Detection System

Notifier by Honeywell: FAAST TM Fire Alarm Aspiration Sensing Technology

INSTALLATION AND MAINTENANCE INSTRUCTIONS 6500R AND 6500RS REFLECTIVE TYPE PROJECTED BEAM SMOKE DETECTOR

TX7130. Conventional Reflective Beam Detector Installation and Operation Manual. TANDA UK Technology Copyright 2015, All right reserved.

Vigilant MX4428 Fire Alarm System

The supplier and installer of the system should be approved by the local civil defence authority.

HART XL High Sensitivity Smoke Detection

FireClass. Introducing a new class of fire detection

Why choose Fireray? Why use a Beam Smoke Detector? Product Range.

INSTALLATION AND MAINTENANCE INSTRUCTIONS 6500 AND 6500S REFLECTED TYPE PROJECTED BEAM SMOKE DETECTOR

D2E Duct Smoke Detector

MINERVA. Marine. Fire Detection. MX T2000 Panel Range. Features: MINERVA Marine Panel Range

Sensepoint XCL Fixed Gas Detector

Sensepoint XCL. Gas Detection. Fixed Gas Detector FEATURES & BENEFITS. Flexible Output Options. Visual Integration. Faster Installation

Building Technologies

PROTECTION THAT MAKES SENSE Bluetooth Enabled Gas Detector

High-precision aspirating smoke detectors for every requirement.

High-precision aspirating smoke detectors for every requirement SecuriRAS ASD 535, ASD 532 and ASD 531 aspirating smoke detectors

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable

good things in small packages

Pedestrian Swing and sliding doors. Accessories

XC10 combined fire detection and extinguishing control

Aspirating Smoke Detection for Large Area Coverage Applications

ORBIS PRODUCT GUIDE. Optical Detector. Multisensor Detector. Heat Detector. Mounting Bases

Installation Instructions

The CWSI System CALL WITH QUESTIONS. RELY ON OUR KNOWLEDGE. DEPEND ON OUR EXPERIENCE. (800)

CONVENTIONAL >FIRE DETECTION C400 SYSTEM FIRE DETECTION

Open-area Smoke Imaging Detection (OSID)

APPLICATION OF VISUAL FLAME DETECTION

Protecting you and your home

F220-B6PS/M. Installation Guide. Addressable Detector Bases

FIRE ALARM SOLUTIONS THAT FIT YOUR NEEDS

Smoke Detector Testing

Installation and Operation Manual

Evolution Analogue Addressable Fire System

Notifier by Honeywell: FAAST TM Fire Alarm Aspiration Sensing Technology

System 800 Addressable Fire Detection & Alarm System

CO 2 Laser. High Reliability and Performance

Cerberus PRO intelligent fire protection. A comprehensive portfolio of innovative and industry-leading technology.

ALK-V PHOTOELECTRIC SMOKE SENSOR

Multi-Point Peripherals

four Vigilon Compact Analogue Addressable Fire Detection & Alarm System 4/1

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

TECHNICAL DATA SHEET ADDRESSABLE FIRE ALARM SYSTEMS FIRE ALARM CONTROL PANEL LF-6100 A 1/2

Reflective Beam Smoke Detector

IFD-E Flame Detector User Manual

Transcription:

Conventional Detectors ECO1000

The world s finest manufacturing facility Sensor s European products are researched, designed and manufactured at our 10,000m2 state-of-the-art facility in Trieste, Italy. Quite simply, it s the best of its kind. Advanced technology and manufacturing processes coupled with dedicated staff ensure precision manufacturing and incomparable quality control. And 100% testing ensures that nothing leaves our doors unless it s in perfect working order and capable of providing years of trouble-free protection. We complement this unique offering with a global network of fire systems integration and distribution partners who serve end-users, consulting engineers and specifiers in more than forty countries. All share in our business expertise and, of course, our passion for perfection.

European European Head Offices Office Sensor Europe Sensor Europe Javastrasse 2 15-19 Trescott Road 8604 Hegnau Trafford Park Switzerland Smallwood Redditch B98 7AH United Kingdom European Manufacturing Centre Sensor Tel: +44 (0) 1527 406700 Via Caboto 19/31527 406699 Fax: +44 (0) 34147 Trieste UK Freephone: 0800 587 5675 Italy Tel: +39 040 949 0111 European Manufacturing Centre Fax: +39 040 382 137 Sensor Email: sse.sales@systemsensor.com Pittway Tecnologica S.p.A www.systemsensoreurope.com Via Caboto 19/3 34147 Trieste Italy Tel: +39 040 949 0111 Fax: +39 040 382 137 Email: sse.sales@systemsensor.com www.systemsensoreurope.com Copyright 2005 Sensor. Allreserved. rights reserved. Copyright 2012 Sensor. All rights All technicaldata data is correct atoftime of publication and to ischange subject to change notice. All trademarks All technical is correct at time publication and is subject without notice. without All trademarks acknowledged. acknowledged. Installation information: in order to ensure full functionality, refer to the installation instructions as supplied. Installation information: in order to ensure full functionality, refer to the installation instructions as supplied. LTR153-2 LTR153-3

Outline Technical Specification Operating voltage: 8-30VDC (nominal 12 or 24VDC) Detector height: 42mm (optical) or 50mm (thermal & photo-thermal) Detector diameter: Detector weight: from 70g Single, multi-function LED indicator Standard base with remote LED output Dust tolerant optical chamber design Unique remote laser test unit Simple Routine Testing A major advance in conventional smoke detector technology By combining advanced technology often found in top of the range analogue detectors with the ease of use and cost effectiveness of a conventional unit, Sensor brings the ECO1000 The range boasts many features previously only found in the more sophisticated - and therefore expensive analogue addressable models. Sensor is the first manufacturer to include such features in a conventional detector, improving the levels of protection and reducing false alarm rates in the smaller and less complex systems where the complexity of an analogue addressable system is not required. Traditionally routine testing involved physical access to the installed unit, a time-consuming procedure often requiring the use of step ladders or long poles. The ECO1000 can be tested from ground level using a laser based remote alarm test unit. The modulated laser beam is directed at the detector's LED; the unit responds to the commands and latches into alarm. What could be simpler? Key Features Microprocessor based products provide a more intelligent solution Special algorithms provide both a constant sensitivity level between service intervals and eliminate spurious alarms resulting from electrical noise Photo thermal model provides outstanding protection Laser-based remote test unit no need for ladders and towers EN54 Certified (2000 edition) Photoelectric, photo thermal and thermal detectors Improved chamber design minimises the effects of dust contamination 8 to 30VDC operating voltage range provides compatibility with both fire and security systems -30 to +70 C operating temperature range Choice of bases (including a 12V relay version) Automatic drift compensation

The family consists of a photoelectric smoke detector, a combined photo-thermal smoke and heat detector, fixed 58 C and 78 C thermal detectors and rate of rise thermal detectors, all fitting common low profile or deep bases. The low profile, unobtrusive design blends in with both traditional and modern premises, enabling them to be installed in any location. ECO1002 The ECO1002 photo-thermal detector is a true multicriteria unit. The output levels from both the optical chamber and the thermistor are continually monitored by the onboard processor, using algorithms developed specifically for the unit. An alarm signal is enabled in the detector once the processor is satisfied that an incipient fire has been detected. By using a combination of inputs, the incidence of false alarms is reduced while at the same time, the response time to a rapidly developing fire is also reduced. ECO1003 The ECO1003 photoelectric smoke detector s chamber has been specifically designed to be highly tolerant to the long term build-up of dust and other airborne contaminants. This high level of immunity significantly reduces the potential for unwanted alarms caused by settled dust increasing the detector s sensitivity. Additional immunity to unwanted alarms arising from shortlived transients is also provided through the use of special signal processing. The end result is an extremely stable detector with the potential to extend significantly the period before cleaning is required. ECO1004T, ECO1005T, ECO1005 The ECO1000 family consists of three thermal detectors. 58 C fixed temperature (ECO1005T), 78 C fixed tempertature (ECO1004T), and a rate of rise detector (ECO1005). The fixed operating point units are suitable for use in areas where rigid changes of temperature can normally be expected; the rate of rise device in areas where the temperature will usually be pretty stable.

ECO1002 ECO1003 ECO1005T 58 C/EC01004T 78 C ECO1005 Photo thermal detector Photo-electric detector fixed temperature detectors rate of rise thermal detector Operating voltage: Typical stand-by current @ 25 o C: Maximum alarm current: Operating temperature range: Thermal element trigger point: Maximum humidity: Colour finish: Case material: Diameter: Detector height (including base): Weight: Weight (including base): Wire gauge for terminals: 60uA at 24V dc 70mA at 28V +58 o C 50mm 78g 123g 45uA at 24V dc 70mA at 28V dc N/A 42mm 75g 120g 55uA/60uA at 24V 70mA at 28V dc +58 o C/+78 o C 50mm 70g 115g 55uA/60uA at 24V 70mA at 28V dc Rapid Change or +58 o C 50mm 70g 115g