Flexible Air-sampling Smoke Detection

Similar documents
Aspiration Systems for Smoke Detection

Buys Time. Aspirating Smoke Detection

The World's No. 1 Brand of Air-sampling Smoke Detector

FAAST. Fire Alarm Aspirating Sensing Technology

HART XL High Sensitivity Smoke Detection

The World's No. 1 Brand of Aspirating Smoke Detector

HART XL High Sensitivity Smoke Detection

FAAST. Fire Alarm Aspirating Sensing Technology

The World s No. 1 Brand of Aspirating Smoke Detection

VESDA VLP. Engineering Specification

Buys Time. Aspirating Smoke Detection

The World's No. 1 Brand of Aspirating Smoke Detector

Why Hart XL Aspirating Smoke Detection?

FAAST. Fire Alarm Aspiration Sensing Technology

AnaLASER II Detector. Protection Systems. A UTC Fire & Security Company. High-Sensitivity Smoke Detector (HSSD ) FEATURES DESCRIPTION

Aspir A ation spir P R O D U C T S

Intelligent Earliest Warning Aspirating Fire Detector

Aspirating Smoke Detection PRODUCTS. Accessories Piping Conventional and Intelligent Detectors

Open-area Smoke Imaging Detector. Engineering Specification

GasGard 100 Control System

LaserFOCUS VLF-250 Engineering Specification

For Complete Fire and Gas Solutions

High-precision aspirating smoke detectors for every requirement.

High-precision aspirating smoke detectors for every requirement SecuriRAS ASD 535, ASD 532 and ASD 531 aspirating smoke detectors

Aspirating Smoke Detection

Notifier by Honeywell: FAAST TM Fire Alarm Aspiration Sensing Technology

LINEAR HEAT SERIES FIBER OPTIC LINEAR HEAT DETECTION SYSTEM

Notifier by Honeywell: FAAST TM Fire Alarm Aspiration Sensing Technology

I N T E L L I G E N T A S P I R A T I N G. Intelligent Aspirating Fire Detector. Intelligent Earliest Warning Aspirating Fire Detector

FAAST PRODUCT RANGE Aspirating Smoke Detection

ALK-V PHOTOELECTRIC SMOKE SENSOR

IR4000. Point Infrared Combustible Gas Detection System. The Reliable and Flexible Safety Solution That s Low Maintenance

EARLIEST SMOKE DETECTION WITH MAXIMUM FLEXIBILITY

Aspirating Smoke Detection PRODUCTS. Accessories Piping Conventional and Intelligent Detectors

and Aspirating Smoke Detection

Aspirated Smoke Detectors

ADPRO PRO Series by Xtralis

The Next Generation of VESDA Aspirating Smoke Detection Technology

FireNET Vapor VPR-15. Product Guide. October 2012 Document: Part Number: HA

TrueAlarm Analog Sensing

Analogue Detectors. Series 200 plus

Recalibrate the way you look at gas detection

-Industrial. W hen All Else Fails... Difficult Applications. The Only TRULY Industrial Air Sampling Detector For Hostile and Difficult Environments

GE Security Vigilant Fire & Life Safety. Easy. V-Series Intelligent Life Safety Systems

Aspirating smoke detection

FireNET Vapor. Pipe Network Design Guide. June 2013 Document: 25845_00 Part Number: HA

Accurate, cost-saving and reliable Natural gas analyzer SITRANS CV SITRANS CV. Answers for industry.

Integrated Security Solutions

Maxline 2 Thermal Imaging Solutions for Manufacturing

VESDA. Accessories Guide. May 2011 Document: 10258_06 Part Number: 30012

Accuracy by Design Products for the HVAC Professional

SIL 2. Ultima X Series Gas Monitors CERTIFIED

FiberSystem. Fiber Optic Linear Heat Detection for Special Hazard Applications

VICOTEC450 EXTRACTIVE VISIBILITY MEASURING DEVICES EXTRACTIVE VISIBILITY MEASUREMENT FOR INCREASED SAFETY IN TUNNELS

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

FAAST Beyond Standard Methods of Detection

Aspiration Detection.

Solution F2. Fire Alarm Control Panels one step ahead.

CONTAMINATION CONTROL FOR ELECTRONIC AND SEMICONDUCTOR APPLICATIONS

Products and performance

Compressed air quality meas. according to ISO 8573 Residual oil content - particles - moisture

MSA Fixed Gas & Flame Detection for the Automotive Industry

THE STANDARD OF EXCELLENCE WDG-V SERIES COMBUSTION ANALYZERS

Danfoss gas detection unit Type GD Heavy Duty

Temperature Solutions Line Card

FireNET Vapor VPR-SD2

Setting the New Standard in Chiller Technology ±0.1 C ZEROPOINT CHILLER SERIES

Industrial Strength Leak Detection

The LC-100 s valved manifold controls the flow of air and allows the LC-100 to accurately monitor liquid levels with a minimal air usage.

LEARNING SPECIAL HAZARD DETECTION TYPES

YOUR PARTNER IN FIRE & GAS DETECTION

Power Generation. ASD 535 Application Report

ID3000 intelligent. fire alarm panel

PANELS, KEYPADS & MODULES. Take Fire Protection to the Next Level Fire Products from DSC

Arc Fault Protection System D1000

Air Sampling Smoke Detection

Different types of Fire Alarm System

Tel: +44(0) Fax: +44(0) /17 LGM Products Ltd. Web: ISO 9001:2015 certified

D1000 Arc-fault Protection System

Aspirating Smoke Detection (ASD) Systems Fire Detection

INSTALLATION AND MAINTENANCE INSTRUCTIONS TC866E Series LASER ASPIRATED SMOKE DETECTOR

Section PERIMETER SECURITY SYSTEMS

Introduction Portable Meters Transmitter Probes RELATIVE HUMIDITY

Early Warning Fire Detection Engineering

WG Buried Cable Perimeter Detection System

FEATURE ARTICLE. The PLCA-800 Series Inline Particle Sensor for Chemical Solutions. Yoshihito Yuhara. Abstract

Danfoss gas detection units

Analyze IT. Process Gas Chromatograph. PGC2000 Series

GE Security EST Fire & Life Safety. Sophisticated io-series. Intelligent Life Safety Systems for small to mid-size buildings

ID50series. intelligent fire alarm panels

Why choose Fireray? Why use a Beam Smoke Detector? Product Range.

Substation Monitoring System

Cerberus PRO intelligent fire protection. A comprehensive portfolio of innovative and industry-leading technology.

Multi-Spectral, Digital, Infrared Electro-Optical. FSC Model No. s. Unitized, Two Stage, Quick Response Flame Detectors.

Mass Sensors, Inc. Profile. Applications. Technology Baur Blvd, St. Louis, MO (314)

CONVENTIONAL >FIRE DETECTION C400 SYSTEM FIRE DETECTION

A New Standard of Excellence

Sitron s CF Line of Flow Switch Monitors

Ronan Model X96S Series Weighing System

CIRRUS PRO. User Manual and Responsibilities ASPIRATING FIRE DETECTOR

Transcription:

Flexible Air-sampling Smoke Detection BY

Technology Pioneers in Highsensitivity Air-sampling Smoke Detection Systems Providing Solutions Beyond Traditional Smoke and Fire Detection Hochiki, a world-leader in smoke detection and fire alarm equipment, introduces a new wide-range of air-sampling smoke detection systems - from an aspirated point-in-a-box (PIAB) detector to the unique 15-channel addressable detector. FireNET Vapor detectors excel in area coverage and powerful performance and are suited to a host of applications stand-alone or networked, smoke and even environmental monitoring in the most demanding environments. These state-of-the art detectors, built for flexibility and dependability, are found in power stations, telecommunication sites, mines, IT facilities, LCD fabs, semiconductor clean rooms, prisons, warehouses, cold storage rooms, harsh and hazardous areas, trains, historic buildings, museums and even in residences. The FireNET Vapor range provides powerful diagnostic information and communication with monitoring, programming and trending information of all detector functions fully accessible from virtually anywhere. Approved worldwide and manufactured according to the strictest ISO 9000 quality control procedures, the FireNET Vapor range includes both air-sampling point detectors and very highsensitivity ASD systems.

How do the World s Finest Airsampling Systems Work? The FireNET Vapor VPR series high-sensitivity ASDs are instrumentquality nephelometers collecting scattered laser light from smoke particles over a full 360-degree sweep. The resulting sensitivity is 0.0003% obs/ ft (0.001% obscuration/m), which is several hundred times more sensitive than conventional smoke detectors. This sensitivity, coupled with advanced processing and filtration, enables FireNET Vapor VPR systems to be used in the world s most demanding applications and environments. Photo receiver Laser beam Sampled air inlet from network of pipes Detection chamber/filter cartridge: 360-degree light guide collector Hundreds of times more sensitive than conventional smoke detectors The instrument-quality optics found in FireNET Vapor detectors are protected by a rugged, removable optical chamber and filter, enabling field serviceability in the dirtiest of environments. Understanding TIME The image below shows the evolution of a fire on an overheating printed circuit board in a computer cabinet. The event progresses from releasing small invisible particles into a raging fire over a substantial period of time. The more time you have to react to an event, the less likely significant damage will occur, ensuring business continuity. The additional response time provided by early detection enables minor events to be investigated with minimal business disruption before fire can cause catastrophic loss. VPR Alert invisible smoke VPR Alarm VPR-SD1 Alarm visible smoke VPR-SD2 Alarm Smoke Sensor Flame Sensor Alarm raging fire Extinguishant Release Smoke density %/m Typical time to fire Up to 0.02 >1H 0.01-0.1 45 min 0.06-0.9 20 min 1.0-4.0 10 min 10-20 0 min

When Every Second Counts When a fire strikes, very early warning high-sensitivity air-sampling smoke detection (ASD) is the only solution for protecting personnel and property. The FireNET Vapor ASD actively draws air from the protected area through a network of rigid sampling pipes perforated with sampling holes along their length. This pneumatic system is powered by a 2,000 Pa aspirator fan that functions in open, very high-airflow areas, air-conditioned environments and clean rooms. Other air-sampling systems typically operate on a tenth of the FireNET Vapor VPR s suction, which renders them ineffective in more challenging and difficult applications. Key Features FireNET Vapor VPR-1, VPR-4, VPR-6 FireNET Vapor VPR-1P Single, four and six areas Up to 21,500 sq. ft. (2,000 m 2 ) of protection High-sensitivity laser detection 0.0003% to 6% obs/ft (0.001% to 20% obscuration/m) Modular, optional relay output units Optional 4-20 ma output module 24 VDC operation (standard) Small compact footprint Up to 9,150 sq. ft. (850 m 2 ) of protection 0.0003% to 6% obs/ft (0.001% to 20% obscuration/m) IP65 24 VDC operation 4 alarms - Alert, Action, Fire 1, Fire 2 Up to 328 ft. (100 m) sampling pipe per channel TCP/IP Ethernet interface Remote monitoring support Powerful 2,000 Pa fan RS232 and RS485 Modbus Logs up to 20,000 events Optional output module Unique field removable and serviceable optical chamber Serviceable, two-stage particle filter External in-line air filters for harsh environments Closed-loop sampling for hazardous environments Absolute calibration of the detection chamber Microprocessor controlled Approvals: UL, CSFM

When Exact Location is Crucial Standard air-sampling systems are well known for their early warning capabilities. However, in certain applications, it is critical to precisely locate the source of the incident. Where the location is critical and a visual search is impossible to perform quickly, FireNET Vapor s unique addressable air-sampling technology provides a powerful solution. The FireNET Vapor VPR-15 uses unique microbore technology that can monitor up to 15 individual, addressable sampling points. Microbore sampling tubes are simple, flexible and unobtrusive to install, providing a very cost-effective solution for airsampling detection with the integrity of a continuous run of sampling tube. FireNET Vapor VPR-15 0.24 in (6 mm) flexible air-sampling pipe Rapid scan of inlets with rotary selector valve High-sensitivity laser detection 0.0003% to 6.10% obs/ft (0.001% to 20% obscuration/m) 15 pipes, 15 areas 4 alarms - Alert, Action, Fire 1, Fire 2 per pipe Powerful suction rotary vane vacuum pump Large, clear display panel and optional RDUs TCP/IP Ethernet interface Remote monitoring support RS232 and RS485 Modbus Optional 4-20 ma output module and relay modules 24 VDC operation (standard)

Extending the Capability of Traditional Smoke Sensors Air-sampling point detectors are highly effective where traditional smoke detection often fails. FireNET Vapor VPR-SD1 and VPR-SD2 systems are ideal for applications in harsh, dusty and inaccessible spaces, as well as those critical environments that do not warrant the expense of a larger air-sampling system. They also have been applied as unique solutions in intrinsically safe environments. Key Features Single- and dual-channel in one enclosure Internal serviceable cartridge air filter Up to 2 x 328 ft. (100 m) pipes Powerful suction 250 Pa fan IP65 enclosure 24 VDC operation Adjustable airflow UL Listed Sensitive airflow monitoring Double-knock suppression control Air is sampled from the protected area through one or two inlet pipes and then passed through an internal cartridge air filter to a single- or dualchannel controller. The Hochiki ALK-V analog sensor(s) is placed inside. Owners of exclusive residences highly value them for their discrete aesthetics and versatility. FireNET Vapor SD1 and SD2 Networking ETHERNET ETHERNET Local and Remote Monitoring PC Internet

FireNET Vapor Design Plan and Design Your Application Response times and sensitivities for individual sampling points can be accurately modeled during the project planning stage with the FireNET Vapor Design pipe network design tool. Features Graphical image of pipes with sample area coverage Simple wizard for user inputs Modeling for capillaries and drop pipes Support for standard pipe fittings and FireNET Vapor accessories Effective smoke sensitivities for all alarm thresholds for each sampling point Response times for each sampling point FireNET Vapor Explorer Experience Powerful Diagnostics FireNET Vapor Explorer is a comprehensive on-site diagnostic tool for accessing all the internal settings and logged data within the FireNET Vapor product range. Features Intelligent management of FireNET Vapor devices Configuration Installation Commissioning Maintenance Fast device setup, fault resolution and event diagnostics Off-line network configuration before the site visit

Hochiki Protects the Toughest Sites Around Unmanned Sites IT Rooms Fully self-contained Additional environmental parameters monitored Web access Extremely high sensitivity Individual cabinet identification Unaffected by high air speeds Warehouses Pipes can be placed within racking Minimize maintenance costs Access difficult areas that normal detection cannot monitor Correctional Facilities and Detention Centers Tamper-proof air sampling Central maintenance facilities Cold Stores No heated detector bases Very early warning Unaffected by high airflows Simple installation Mines Individual protection of high-voltage switchgear cabinets HV cabinets bolted and not opened easily PLC and control rooms Electrical substations Historic Buildings/ Museums Discrete monitoring Rapid response Protection for valuable assets Exclusive Residences, Apartments, Hotels, Shops and Offices Unobtrusive detection Remote Web monitoring Utility Providers Large area coverage 21,500 sq. ft. (2,000 m2) Transport Ideally suited to long compartments Concealed detection Automatic air pollution compensation Multiple sectors for carriage sets with integral cabs Significant Religious Buildings Unobtrusive detection Earliest detection Wind Turbines Smoke detection control during emergency and operational braking Unaffected by arcing, lightning and static electricity Unaffected by air speeds within the generator Insensitive to environmental conditions 7051 VILLAGE DRIVE, SUITE 100, BUENA PARK, CA 90621-2268 PHONE: (714) 522-2246 FAX: (714) 522-2268 SALES@HOCHIKI.COM WWW.HOCHIKI.COM The contents of this document are provided on an as is basis. No representation or warranty (either express or implied) is made as to the completeness, accuracy or reliability of the contents of this document. The manufacturer reserves the right to change designs or specifications without obligation and without further notice. Except as otherwise provided, all warranties, express or implied, including without limitation any implied warranties of merchantability and fitness for a particular purpose are expressly excluded. This document includes registered and unregistered trademarks. All trademarks displayed are the trademarks of their respective owners. Your use of this document does not constitute or create a licence or any other right to use the name and/or trademark and/or label. This document is subject to copyright owned by Hochiki America Corporation. You agree not to copy, communicate to the public, adapt, distribute, transfer, sell, modify or publish any contents of this document without the express prior written consent of Hochiki America Corporation. BY