Miniveyor. Tough Fans for Tough Jobs! NEW VAF Models now come with a Industry Leading 10 Year warranty upgrade on the fan body.

Similar documents
Great for Rental Stackable: Constructed with interlocking ribs for stacking vertically. Great for storage as they need a minimal footprint

CONFINED SPACE VENTILATION

Confined Space Ventilation equipment

ELECTRIC HEATERS. Fireball Electric Heaters. 10,200btu HEAT OUTPUT. heating. 30,706btu HEAT OUTPUT. 9,600btu. sales hotline

Plenum Fans. Model HPA. Direct Drive

Introduction to Fans. The Basics of Fan Principles and Terminology

, A Product Catalog

Centrifugal Fans, Non-Overloading, Backward Inclined

GALE FORCE VAF-16R. Ventilation Manual

Owner s Manual. Van Ho Pug Mill Power Plus 160 Series

Owner s Manual. Van Ho Pug mill Power Plus 200 Series

Owner s Manual. Van Ho 1HP Pug Mill Power Plus 130 Series

Electric Submersible Pumps

UB20 12V DC. Owner s Manual

5 year fan housing and motor warranty

12 VELOCITY OWNER S MANUAL OPERATING INSTRUCTIONS - MAINTENANCE - SAFETY - TROUBLESHOOTING

VENTING CLEARANCES. BBT NORTH AMERICA Bosch Group. Bosch Water Heating 340 Mad River Park, Waitsfield, VT TWH-V-26 page 1 of 6 rev 01/06

OWNERS MANUAL. PLEASE READ THIS MANUAL BEFORE OPERATION

Portable Dust Collection Systems

Smart Comfort Solutions HIGH VELOCITY DRUM FANS

ALUMINUM REPAIR CERTIFICATION EQUIPMENT. Eliminate hazardous aluminum dust with a Eurovac system. BODY REPAIR CERTIFICATION EII Wet Mix Dust Collector

EBAC MODEL NEPTUNE INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

The Advantages of Choosing Centrifugal Fans

Easy-to-read controller with large rheostat knob and start/stop switch. Explosion proof motor

Portable Vertical Air-Conditioning and Heating Systems

EURAMCO SAFETY S CERTIFIED PRODUCT MARK OF EXCELLENCE

EBAC MODEL KOMPACT INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

AIR SHOWERS CAP701 SERIES

SIOUX STEEL COMPANY GRAIN CONDITIONING EQUIPMENT. Fans, Heaters & Controls

Environmental Design The tank has separating devices at the exhaust port to prevent oil-spraying and to reduce pollution.

Smart Comfort Solutions HIGH VELOCITY DRUM FANS

4VH and 4VHX. 4" Non-Clog Wastewater Pumps Standard (4VH) and Explosion-Proof (4VHX) Construction

GOVE LDMY Extractor Series

48GS(N) STANDARD EFFICIENCY 48GX(N) HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING ELECTRIC COOLING UNITS

48GS HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS

NEPTUNE INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Industrial Contractors Supplies

THE PROFESSIONAL S CHOICE SINCE 1953 INDUSTRIAL HEATING & COOLING CATALOG. masterindustrialproducts.com

EBAC MODEL CD60 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

RSV Chimney Fan USA CAN. Start Up and Configuration. ... Chapter 5. Maintenance and Troubleshooting... Chapter 6. Job Name: Installer:

3000 Series Fan Forced Ceiling Heater Series Commercial Fan Forced Ceiling Heater

Ducted Propeller. Airflow Volume

VariCool VAV Engineering Guide

OPERATION & MAINTENANCE MANUAL MODEL SC-924A SELF-CONTAINED ELECTRONIC AIR CLEANER IMPORTANT: PLEASE READ MANUAL BEFORE OPERATING UNIT

Description. Construction

The PV100x fans feature Class F motor insulation. 5 year fan housing and motor warranty

Industrial Fans & Blowers

AIR SCRUBBER X-3400, X-3500, X-3700

KUH. Horizontal Unit Heater. Applications. Description

OWNER S MANUAL MULTIPURPOSE UTILITY AIR MOVER PLEASE READ AND SAVE THESE INSTRUCTIONS X-400WFK (WITH FILTER KIT) ITEM NO:

THE SHAPE OF VACUUM UV SERIES

DESICCANT AIR DRYERS. BD + CD + CD series

EBAC MODEL BD-150 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Zeus Extreme Owner's Manual

Propeller Fans. Industrial And Commercial Fans Belt And Direct Drive. Your Clean Air Source!

ACCESSORIES ITEM NUMBER. Digital timer, burning and ventilating. RT1, RT2, RT3 IT1 DA1 Thermostat for CH 12/18. fault detector.

LOW PROFILE AIR MOVER

POULTRY MARKET CATALOG

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH


user manual Model #: BLZ-WVH-42

TPP440. owner s guide. air purifier with uv light. air purifier with uv light TP

DC Heat Recovery Unit MVHR Wholehouse heat recovery unit

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH

AHU INSTALLATION & OPERATION MANUAL

LUH HORIZONTAL FAN-FORCED UNIT HEATER

DUCTING & VACUUM HOSE

OPERATION & MAINTENANCE MANUAL MODEL SC SELF-CONTAINED ELECTRONIC AIR CLEANER IMPORTANT: PLEASE READ MANUAL BEFORE OPERATING UNIT

SAFETY PRODUCTS CATALOG

Direct-Drive Gas Power Blowers

WHY SULLAIR? For more information on the IHI-Sullair joint venture, please visit 2,000th IHI-Sullair centrifugal

High Plume Blowers Suggested Specification Section (Master Format 1996) Suggested Specification Section (Master Format 2004)

V * V V V V V-25L-230* V * V *

SELF-PRIMING CENTRIFUGAL PUMPS BMLS-M & BMLS-H

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

S_Series Click to go to the page. S-Series Bag Filter

qüé=`üáãåéó An effective chimney is an important part of any successful wood-burning system.

HVAC. Air Blowers Fans Forced Air Heaters Heating Cables & Insulation Infrared & Radiant Heaters

OPERATION MANUAL AND WARRANTY ELECTRONIC INFRARED ZONE HEATING SYSTEM

GreenJet Transfer Fans

TOP LOAD WASHER AWNA62 TRADITIONAL MADE IN AMERICA, BUILT TO LAST SINCE 1908

MECHANICAL VENTILATION

ENVIRO UNIT ENGINEERING MANUAL KES SERIES

100W Portable Explosion Proof LED Light - (2) LED Lamps - Non-Spark Aluminum Base - Inline Switch

DC-1000 DECAL WORLD KIT. Part # Description Qty Part # Description Qty DECAL KIT

FAN ENGINEERING. Sealing of Fan Housings

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

MANUFACTURED with high-quality components and innovative techniques. DESIGNED for economical, trouble-free performance and long-life reliability

IMPROPER USE OF THIS HEATER COULD RESULT IN FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS

EXTERNALLY HEATED BLOWER PURGE DESICCANT AIR DRYERS. GBPD Series

OFFICINE MINUTE VILLORBA - TREVISO

2014 summer NEW PRODUCT SCOOP INTRODUCING. New Open Front Tool Chest

Electric Submersible Pumps

Series PIN. New Construction or Renovation. Application Flexible Quiet Comfort Damage Protection

TABLE OF CONTENTS. productgroep 01

Kitchen Exhaust Air Cleaning Systems

Cabinet Unit Heaters Steam / Hot Water

EBAC MODEL AD850 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Concrete Applications

Transcription:

Miniveyor Tough Fans for Tough Jobs! Where fumes, smells or dust occur, the Miniveyor fans can move contaminated air out of the building. They effectively exhaust fumes, ventilate confined spaces, and increase the flow of fresh air. Double Protection: The double wall construction protects the inner casing from being dented giving extended product lifetime. Dented or damaged casings are a common cause of failure with traditional metal fans. Less Downtime: The polythene casing is resistant to the normal knocks and bangs of everyday use that can stop a sheet metal fan. Metal fans often dent which can obstruct the fan blade. The Miniveyor units easily withstand blows without denting, giving less downtime and greater productivity. Greater Value: The casing are corrosion free and unlike metal fans will not rust when they are dented, chipped or scratched. They simply last longer and offer greater value for money. Great for Rental Stackable: Constructed with interlocking ribs for stacking vertically. Great for storage as they need a minimal footprint Miniveyor Dual wall construction for rugged reliability. Resistant to dents, & dings, providing reliable continuous operation and less downtime. Polythene body is corrosion free and not effected by chips or scratches. Portable and lightweight 11 to 20 kg Metal Fans Single layer construction - makes fan more vulnerable to damage, which can then impede fan blade rotation. Can rust and corrode easily. Heavier - from 10 kg to 90 kg NEW VAF Models now come with a Industry Leading 10 Year warranty upgrade on the fan body.

Miniveyor Tough Fans for Tough Jobs! VAF-200 Only 7.5 kg the VAF-200 is our smallest and newest Ventilator. Don t be fooled by it s size though as the VAF-200 has an impressive 1350 m³/hr (800 CFM) airflow and is available in either 110V 0r 230V. VAF-300 Our most popular Ventilator!, available in either 110V or 230V. Too much dust to see safely? Filter out the dust by using our 200 litre filter in combination with the VAF-300 VAF-400 Available In 110 & 230V. For maximum airflow the VAF- 400HP gives a massive 7500 m³ per hour. VAF-200 VAF-300 VAF-300P- FRL VAF-400HP Flow - m³/hr - CFM Motor Specification 1350 800 3400 2000 3500 7500 4450 Voltage 110V/230V 110V/230V Pneumatic 110V/230V Phase Single Single Single Power 250 W (1/3 HP) Current (Amps) 110V - 2.6A 230V - 1.1A RPM Dimensions 3450 (110V) 2850 (230V) 1 HP 18 l/sec 110V - 7.1A 230V - 4.9A 3325 (110V) 2750 (230V) 1 HP 110V - 8.8A 230V - 7.2A 3000 3450 (110V) 3250 (230V) Length 33 cm (13 ) 44 cm (17½ ) 44 cm (17½ ) 43 cm (17 ) Width 25 cm (10 ) 36 cm (14 ) 36 cm (14 ) 54 cm (21¼ ) Height 37 cm (14½ ) 54 cm (21¼ ) 54 cm (21¼ ) 56 cm (22 ) Weight 7.5 kgs (16½lbs) 15 kgs (33lbs) 13 kgs (29lbs) 20 kgs (44lbs) Duct Flange Diameter 200 mm (8 ) 300 mm (12 ) 300 mm 400 mm (16 ) Application Examples Welding - Remove the fumes and smoke away from the working area. Perfect for ship repair! Concrete cutting - Remove the dust to see what you are doing when cutting bricks and concrete with diamond saws. Flood Damage - Dry out flooded buildings,

What Every Miniveyor Customer Should Know About the Miniveyor VAF-Series. Dual Wall Plastic Shell: Maintenance is virtually eliminated with a dual-wall, high density plastic shell. Current metal gauge fans will get dinged and banged around. So will our fans. There is one major difference. The metal fans do not absorb the dings and dents. The single layered, thin metal gauge walls will indent. This indent may, and usually does, obstruct the rotation of the fan blade. The fan blade will either stop or break. Either option becomes quite costly. If the unit can be repaired, the fan will be taken out of service while being maintained. Maintenance includes ripping out fan guts (i.e. grill, motor assembly, electrical wiring), pounding out the indents, replacing all necessary components and reassembling. Depending on the amount of damage, purchasing a new ventilator may be less expensive when considering labour repair hours. The plastic shell will absorb the ordinary ding or bang experienced in the field, eliminating the above mentioned costly maintenance procedure. Better yet, because of the dual wall design, if any foreign object punctures the outer wall, the interior fan chamber is protected by the inner wall. The unit will continue operating and costly maintenance charges will be eliminated. The plastic shell makes the VAF-Series corrosion free. Once the paint on a metal gauge fan chips or scratches, rust becomes inevitable. If appearance is a concern, then rust is a problem. Rust reduces metal life and is not attractive. The VAF-Series maintains its high quality exterior finish regardless of use in humid, moist climates. The plastic shell contains an ultraviolet stabiliser, or U.V. inhibitor. Exposure to continuous sunlight rays will not discolour the unit. Electric Motor: The totally enclosed, non-ventilated motor which reduces external substance entry (i.e. any kind of dust). As non-filtered, dusty air passes through open type motors, particles build up on the motor windings. After continued use in a dusty environment, this particle build-up eventually clogs the motor, causing it to overheat. The solution is replacement. The cost is a new unit. The VAF-Series totally enclosed motor reduces particle build up extending motor life.

The motor has a built in thermal protective overload switch. The switch senses extreme temperature rises which can be harmful to the motor. When such temperatures are achieved, the switch automatically shuts down the ventilator. This protects the unit from burning out and saves users from costly repairs or replacements. Duct Diameter: Greater air volume is achieved with a wider duct diameter. movement and its performance in a confined space is the ultimate purpose of ventilation. The VAF-300 12 inch (300mm) duct diameter allows users to extend long duct lengths into hard to reach confined spaces. Greater duct lengths are achieved because the larger fan blade produces more CFM under static load. The VAF-200 uses 8 inch (200mm) duct diameters for a more controlled environment. Flexible Ducting: The VAF-300 can ventilate confined spaces with up to 5x 7.5m (25 ) lengths of flexible duct attached. This allows our ventilator to be used in a diverse range of jobs. For example, underground contractors use long lengths of duct for purging underground tanks, tunnel ventilation etc.. Some jobs require in excess of 37.5m (125 ) of duct. If more than 37.5m (125 ) of duct is necessary on a job, use the VAF-300 as a booster. Simply run 30m (100 ) of duct on one fan, attach the duct end to another fan and attach an additional 30m (100 ) of duct. The total duct length is 60m (200 ). The boosters can be continued in any length required. Run boosters in excess of 1,000 feet! Typical Flow Rates for Miniveyor VAF-300 when fitted with flexible ducting- Flow Rates 110 & 230 Volt CFM M 3 /Hr Free 2000 3,390 7.5 Metres straight 1585 2,690 7.5 Metres 1 x 90 bend 1500 2,550 7.5 Metres 2 x 90 bends 1430 2,430 15 Metres Straight 1315 2,230 30 Metres Straight 635 1,080 Lightweight: The VAF-Series plastic ventilators are lighter than the competition. With a built-in, centrally located handle design, the ventilator is quite portable on any job site. Compared to metal gauge ventilators, our high powered, low weight plastic ventilator is easily carried reducing chances of back injury. Stack: Place ventilators on top of one another. Its cone shaped design allows units to operate stacked, increasing the air volume movement in confined spaces. Corrosion Resistant: An epoxy powder coat is baked onto the steel components to prevent rusting and corrosion. This allows the ventilator to be used in high moisture atmospheres.

Rubber Feet: Centrifugal fans use spring loaded, anti-vibration feet. These shock resistant feet are used because centrifugal fans are built with the motor and the fan blade built off centre. Vane axial fans are symmetrically built, creating a balanced air ventilator. This superior design and engineering does not require anti-vibration or shock absorbent feet. A non-vibrating ventilator can be placed on a sloping surface. Warranty: One year. Not 30 days, not 60 days, not 90 days or 6 months, like other ventilator manufacturers, but one year. Ask and compare. Miniveyor stands behind its quality and design and backs it up with the one year parts warranty. We now provide a 10 year warranty upgrade on the fan body once the product is registered by either returning the registration card or registering online. See the Owner s Manual for warranty details, general safety, safety precautions, instructions for operation and care, parts list and trouble shooting.