ANCHOR BOLT DETAIL. Non-Shrink Grout. Poured In Place, After Equipment Setting. "L" Type Anchor Bolt Carbon Steel AISI 304 S.S.

Similar documents
Custom Pump Controls. The Custom Controls Solution Provider. A New Generation. Complete Management. Page 2

EG Controls. SLIMVIEW 120 VOLT FLOAT SERIES DUPLEX PUMP CONTROL PANEL SPECIFICATION for CITY OF E G

Pump-Down Controller MODEL 4052

tcm100, tcm101 Series Temperature Control Modules and PTS100, PTS100/3 Pipe Temperature Sensors Operations Manual

Installation and application. Leakage detectors, CLS/FLS/FLS10/MiniCAS II

Pump-Up Controller MODEL 4062

SECTION 4000 LIFT STATIONS

Public Safety DAS Annunciator Panel

SECTION SANITARY SEWAGE PUMP STATIONS

SECTION WASTEWATER PUMPING STATION DESCRIPTION

CITY OF MEXICO BEACH REQUEST FOR QUOTES: LIFT STATION PANELS REPLACEMENT

Ç Consilium Consilium US, Inc. 59 Porter Rd Littleton, MA USA

vibration switch

POINT OBSTRUCTION CONTROLLER POC TOUCHSCREEN CONTROLLERS

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: HVAC Standards

Stancor Duplex Oil-Minder System Submittal SE Volt Single Phase Duplex SE-100 Pumps with Floats and Oil-Minder Probe

4300 WINDFERN RD SUITE 100 HOUSTON TX VOICE (713) FAX (713) WEB: IMPORTANT!!!

ACSI MODEL 1410 POWER SUPPLY INSTALLATION INSTRUCTIONS

STATION MODEL: KPCG21-24x48 PUMP MODEL: KEEN KPCG21 VOLTAGE: 230 PHASE: 1 TANK DIMENSIONS: 24 DIAMETER X 48 DEEP

GRUNDFOS SEWAGE & EFFLUENT PUMP ACCESSORIES

SIMPLEX WEATHERPROOF CONTROL PANELS

PO Box 827 Hawley, MN (218) Fax (218)

IVR15-RPS O.D. Solid State Illuminated Rail Remote Power Supply

Type 300 Series Bench Electrode Stabilization Ovens

MAINTENANCE & TROUBLESHOOTING GUIDE LEAK ALARM CHANNEL DRY OIL WATER AUX ALARM HIGH LOW CRITICAL WATER TANK LEVEL ALARM MODEL LDE-740 ADVANCE PAPER

INSTRUCTION MANUAL and DETAILED PRODUCT SPECIFICATION TRIPLEX PUMP CONTROL SYSTEM MODEL NUMBER CPC-3. M336 Rev F. November 21, 2000.

ELECTRONIC FLAME SUPERVISION MULTI-BURNER

SAFETY INFORMATION AND WARNINGS

ESSEX ENGINEERING CORPORATION

ITC 2000 HEATING CONTROL CABINET. Installation & Operation Manual

APS-300 SERIES DUAL VOLTAGE UL 294 LISTED ACCESS CONTROL POWER SUPPLIES

Securitron Magnalock Corporation S. 51 st St., Ste. 102 Phoenix, AZ Phone: (800) MAGLOCK

Check It Panel. 1 Phase Simplex Demand Dose Operation, Maintenance & Installation Manual. Introduction. Safety Guidelines

Pump Logic User Manual CB-1000 P/N ILK-CB1000-1

Reliable Long-Term Solutions For Your Toughest Pump

1.1 REFERENCES.1 American National Standards Institute/National Fire Protection Association (ANSI/NFPA).1 ANSI/NFPA 20, Centrifugal Fire Pumps.

Basin Heater. user manual INSTALLATION OPERATION MAINTENANCE

Three Phase Simplex. Installation (937) Installation Instructions and Operation/Troubleshooting Manual. Installation of Floats.

Revision: None DCN No. First Issue Date: November 30, 1998 Product: Standard DCT, 120-volts

PRODUCT PRICE BOOK Pricing Effective February 4, We ve Got Panels Under Control.

SCE170 SERVICE PARTS

MANUAL RESET ALARM RELEASE

Notes: Warrick Series 67 Intrinsically Safe Multi-Function Control Installation and Operation Bulletin

K4RB(X) 4 Submersible, Recessed Impeller (Class 1, Div. 1, Groups C & D Hazardous Location)

RANGE. 2600/1950 Watts. 240/208 Volts BAKE ELEMENT /2100 Watts. 240/208 Volts. 90 degree BAKE ELEMENT Watts.

Sentry LIQUID LEVEL ALARM MODEL 100 OPERATING MANUAL.

SUBMERSIBLE PUMPS For water with particulate matter 2 pole - 50 Hz 2 ranges : SS 304 & SS 316 L

DLKF. EBARA Submersible Sewage Pumps Specifications Project: Model: Chk d: Date:

Barnes Oil Sensor Switch

Marley Collection Basin Heater Circuit

K4RH(X) Solids-Handling Pumps

Centro-Matic Automated Lubrication Systems System Controls

4VH and 4VHX. 4" Non-Clog Wastewater Pumps Standard (4VH) and Explosion-Proof (4VHX) Construction

AccuBrine automated brine maker Technical Specifications

GPF Dimming Panels. GRAFIK Systems SPECIFICATION SUBMITTAL

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.

KGP(X) Grinder Pumps HP Grinder Pump, 3 Phase (Class 1, Div. 1, Groups C & D Hazardous Location) Performance Curve.

Model VPS Pressure Limiting (VFD) Electric Fire Pump Controller with Soft Start Bypass

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

MANUAL RESET ALARM RELEASE

Greentrol Automation, Inc.

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

Operation Manual. Rev. E GEM-II Self Contained Gas Detector.

We ve Got Panels Under Control.

Soft Start Series MP700 Solid State, Reduced Voltage

Two-Position Electric Duplex Room Thermostats

Commercial and Light Industrial Fire Alarm Control Panel

product brochure Sump, Effluent and Sewage Controls

MASTER PRESSRE MAINTANENCE CONTROLLER. Models PMCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

108A OTP1800. Grid Support. General Description

SECTION DOMESTIC WATER PRESSURE BOOSTING SYSTEMS (VFD) PART 1 - GENERAL 1.1 SUMMARY

UHIR Series. Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater. Owner s Manual

OPTICAL TURNSTILE SYSTEM

STEAMPRO. Steam Generator Troubleshooting and Service Guide

PHYSICAL FACILITIES Consultant s Handbook Specifications Division 21 Fire Suppression 3000 Fire Pumps

Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL.

Specifications. STEALTH Simplex, Wall Mount For SGV, OGP & OGV Grinder Pumps Control Panels & Accessories.

SERIES WM-20(T) & WM-40(T)

SP-1000X. Panic Device Power Controller Installation Guide. Rev

Electric Heat Accessory Installation Instructions

TraceTek Sensing Module Installation, Operation and Maintenance Instructions DESCRIPTION SPECIFICATIONS APPROVALS TYPE NM

RDM LOCK G Series Electromagnetic Lock. Listings. Standard Features. Ordering Information:

Fluid Cooler Fan and Pump control panel

The Clark-Reliance Corporation TWIP System Installation and Maintenance Instructions - Form E112 -

Mounting Plate ADA/HOSPITAL SIGNALING DEVICES 14-8 FEATURES. > Momentary switch push button > Stainless steel faceplate

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

MaxGard. Interconnection Systems. Durability. Performance. Safety

FLT93 Installation, Operation and Troubleshooting Guide

Elevator Sump Kits and Components

MSM400 Ultrasonic Suspended Solids Monitoring and Control System

Single Phase Simplex SXL21=3, SXL24=3, SXH21=3, and SXH24=3

DTA04. Motor thermistor relay. Benefits. Description

DTA. Motor thermistor relay. Benefits. Description

VEHICLE EXHAUST DETECTOR

Wiring Instructions for the 2900 Series FIREGUARD Combination Door Closer-Holder and Releasing Device with Integral Smoke Detector

SCR/SCRF SERIES. Industry s First Choice for Time-Tested Proven Reliability FLOAT BATTERY CHARGERS. Single-Phase Input

ELP21LU3-LF-HLOL THREE CHANNEL

INTRODUCTION / TABLE OF CONTENTS

Model Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products:

Transcription:

ANCHOR BOLT DETAIL Heavy Flat Washer Heavy Hex Nut UNC Th'd Mounting Flange Of Equipment To Be Mounted C B A D Non-Shrink Grout. Poured In Place, After Equipment Setting. Heavy Flat Washer Heavy Hex Nut UNC Th'd B "L" Type Anchor Bolt Carbon Steel E A D AISI 304 S.S. C Anchor Bolt Sleeve Anchor Bolt Sleeve, As An In-Place Form To Provide A Grout Pocket Around The Anchor Bolt. Heavy Flat Washer Heavy Hex Nut UNC Th'd ITEM A B C D E Submersible Base Elbow for: SR 5/8 8 7 EL 3/4 8 7 Dry Pit Submersibles With Support Elbow 3/4 8 7 All Others 1 10 4 1/4 10 Date 9/1/07 PAGE A003

Mercury-Free Level Tilt Switches Pilot Duty Industrial Control Equipment Yeomans Chicago Corporation Type "GSI" with Stabilizing Weight PVC Type SJO - cond. # 18 AWG 41 Strand 300 volt electrical cord The float is a direct acting float switch. Each float contains a single-pole snap-action switch which actuates when the longitudinal axis of the float is horizontal and deactuates when the liquid level falls 3-1/" below the activation level. The float is a chemical resistant polypropylene casing with a firmly bonded electrical cable protruding. One end of the cable is permanently connected to the enclosed snap-action switch and the entire assembly is encapsulated to form a completely watertight and impact resistant unit. NOTE: Actual shape of float may vary slightly from these illustrations. 4.5" Yeomans Chicago Corporation 3" Pilot Duty 7 AMPS 10 VAC 3.5 AMPS 40 VAC Polypropylene Casing contains hermetically sealed snap-action switch N.O. - Black Switch Arrangement Cable Length (ft.) Suspended Types Model No. Ship Wt. (lb.) Normally Open ' ' ' ' 30 40 50 GSI30NO GSI40NO GSI50NO 5 6 7 P/N C9-4-37 Stainless Steel Wall Mounting Bracket w/ four (4) adjustable cord grips for Type "GSI" Floats ' ' 60 GSI60NO 8 Junction Box (if required) To power and motor starters Typical U.L. Pump Control Curcuit Pump Down Line Voltage R R R1 R1 High Water Alarm (Optional) Start Lag / Stand-by Pump Start Lead / Duty Pump NO Start Lag NO Start Lead NO Common Stop R R1 Pilot Contact Lead Pump Motor Starter Pilot Contact Lag / Stand-by Pump Motor Starter Typcal "Duplex" Control Arrangement Common All Pumps Stop Date 1/1/07 PAGE A005

DUAL-CHANNEL SEAL FAILURE ALARM RELAY P/N C9-7-79 The dual seal failure module is a specialized control for monitoring seal failure. Each relay provides monitoring of two () submersible pump motors. Leaks are detected by sensing the conductivity of the contaminated fluid through the moisture detection probes located in the motor seal chamber and stator housing. In the event of a seal leak, the module energizes one of its SPST output relays indicating that seal maintenance or replacement is required before the motor is damaged. The sensitivity of the probe inputs is field adjustable. When the resistance between one of the probe inputs and the common connection drops below the sensitivity setting, the corresponding output relay and LED are activated. Date 9/1/07 PAGE A017

COMBINATION SEAL FAILURE / OVERTEMP SIMPLEX ALARM RELAY P/N C9-7-80 Date 9/1/07 PAGE A019

GENERAL: COMBINATION SEAL FAILURE / OVERTEMP SIMPLEX ALARM RELAY The Combination Seal Failure/Overtemp Alarm Relay is a specialized control for monitoring seal failure and thermal overload of one (1) submersible pump motor. Leaks are detected by sensing the conductivity of the contaminated fluid through the moisture detection probes located in the motor seal chamber and stator housing. Over-temperature is detected by a normally-closed switches connected in series and embedded in the motor stator windings. The over-temperature function incorporates a bi-stable relay that retains its position during power failures. OPERATION: The states of the unit's relay outputs are determined by the series combination resistance of the leakage and temperature sensors. Under normal conditions the resistance remains between the leakage and over-temperature sensitivities, and both output relays are de-energized. If the temperature switch opens, the over-temperature relay latches on until the remote reset button is pressed. Two conditions must be met for reset to occur: 1- Power must be applied - The temperature switch must be closed If the leakage sensor resistance drops below the leakage sensitivity setting, the leakage relay energizes. When the leakage condition clears, the relay resets automatically. PAGE A00 Date 9/1/07

SERIES 16 MOISTURE DETECTION RELAY (NO ENCLOSURE... MUST BE MOUNTED INSIDE CUSTOMER'S PANEL) When the pushbutton is depressed the indicating lamp will be illuminated to indicate: A) power is supplied to the control, B) the control is operative, and C) wiring is intact. This procedure should be performed periodically to confirm integrity of the circuit. The integrity of the moisture probe wiring may be checked with an ohmmeter. Measured resistance between (3) & (4) should exceed 300,000 ohms. 3.5 (88.9).75 (69.9).375 (60.3) 8 PIN OCTAL SOCKET 0.15 (4) (50.8) 1.69 (4.9).31 (58.7) 1.15 (39.7) 0.17 (4.4) 0.63 (15.9) P/N 97897498 10 VAC Supply Power Relay Energized - 4.4 VA N H Denotes 10 VAC Field Wiring WHITE WIRE Jumper SEAL LEAK A 16MN1A0 Control 50K Ohm Sensitivity, Inverse Operation. 1 8 7 3 4 5 6 SYS OK G TEST P/N DESCRIPTION 97897498 BARE RELAY, 115V, WIRING AND ENCLOSURE BY OTHERS. Probe Sensing Circuit 1 VAC, 1.5 ma Run separate from motor leads. MOISTURE PROBES Denotes 1 VAC Field Wiring LC-1 DETECTING MOISTURE - ALARM PILOT ON - SYSTEM OPERATIONAL PILOT OFF LC-1 NO MOISTURE - ALARM PILOT OFF - SYSTEM OPERATIONAL PILOT ON TEST BUTTON ACTIVE - ALARM PILOT OFF (RELAY ACTIVE) - SYSTEM OPERATIONAL PILOT ON Date 4/18/11 PAGE A01

15/3 MOISTURE DETECTION RELAY TYPE 800A (NO INDICATING LIGHT) 5 6 1/4 WARNING - ELECTRICAL SHOCK HAZARD DURING AND AFTER REMOVAL OF COV- ER. DISCONNECT ALL INCOMING ELEC- TRICAL SUPPLIES BEFORE PROCEEDING TO REMOVE THE ENCLOSURE COVER NEMA TOP VIEW 7 33/64 4 WEATHER PROOF P/N 97897501 3/8 7 33/64 PUMP MOTOR MOISTURE DETECTOR 7 1/ 6 3/4 SYSTEM OPERATIONAL SYSTEM TEST NOTE: ENCLOSURE DIMENMSIONS MAY VARY BY MANUFACTURE. FRONT VIEW RIGHT SIDE VIEW 1/4 10 VAC Supply Power Relay Energized - 4.4 VA N H Denotes 10 VAC Field Wiring Jumper SEAL LEAK* A 16MN1A0 Control 50K Ohm Sensitivity, Inverse Operation. 1 8 7 3 4 5 6 SYS OK G TEST P/N DESCRIPTION 97897501 NEMA 4 ENCLOSURE, 115V, NO ALARM LIGHT. MODEL 810A Probe Sensing Circuit 1 VAC, 1.5 ma Run separate from motor leads. Denotes 1 VAC Field Wiring *REMOTE SEAL LEAK ALARM LIGHT BY OTHERS MOISTURE PROBES Date 4/18/11 LC-1 DETECTING MOISTURE - ALARM PILOT ON - SYSTEM OPERATIONAL PILOT OFF LC-1 NO MOISTURE - ALARM PILOT OFF - SYSTEM OPERATIONAL PILOT ON TEST BUTTON ACTIVE - ALARM PILOT OFF (RELAY ACTIVE) - SYSTEM OPERATIONAL PILOT ON PAGE A03

INSTALLATION AND OPERATING INSTRUCTIONS GENERAL: The type 800A is a conductance-actuated control for detection of moisture in the oil chamber of a submersible pump motor. It is used as a warning device to indicate a seal leakage and to signal the need for preventative maintenance. INSTALLATION: Mount control box vertically on wall or other solid structure and accomplish all indicated wiring. Terminals on the control are numbered and are in the same relative position as shown on the wiring diagram. Terminal pair 1- must be continuously energized from an A.C. supply line of electrical characteristics shown on the data plate. Contacts 8-6 and 8-7 are available for load duty, and if required, must be wired in series with the load device or devices, and that series branch circuit connected across a power source compatible with the load. Terminals 3-5 are connected to the moisture sensing probes in the motor marked W1-W via the cable provided with the motor. OPERATION: The oil surrounding the probes is nonconductive and the control will be de-energized. An influx of moisture past the outer seal and into the oil reservoir will cause the relay to energize. Load contacts 8-6 and 8-7 will change from their normally open or normally closed position when the control energizes. TEST PROCEDURE: A normally closed pushbutton and neon indicating lamp are provided as a part of the control for testing the moisture sensing relay. The motor manufacturer has provided a 330,000 ohm resistor across the probes inside the motor to complete the test. When the test pushbutton is depressed, the contacts 8-6 and 8-7 will change condition to indicate: (A) power is supplied to the control (B) the control is operative (C) the wiring is intact To test the wiring from the relay to the moisture probes in the motor, de-energize and lock out power to the moisture relay. Use a multi-meter and measure the resistance between the relay connection points 3 and 5. Resistance should be greater than 300,000 ohms showing that the wiring from the relay to the moisture probes in the motor are intact. PAGE A04 Date 4/18/11

15/3 MOISTURE DETECTION RELAY TYPE 810A (WITH INDICATING LIGHT) 5 6 1/4 WARNING - ELECTRICAL SHOCK HAZARD DURING AND AFTER REMOVAL OF COV- ER. DISCONNECT ALL INCOMING ELEC- TRICAL SUPPLIES BEFORE PROCEEDING TO REMOVE THE ENCLOSURE COVER NEMA TOP VIEW 7 33/64 4 WEATHER PROOF P/N 97897489 3/8 7 33/64 PUMP MOTOR MOISTURE DETECTOR 7 1/ 6 3/4 SYSTEM OPERATIONAL SYSTEM TEST NOTE: ENCLOSURE DIMENMSIONS MAY VARY BY MANUFACTURE. FRONT VIEW RIGHT SIDE VIEW 1/4 10 VAC Supply Power Relay Energized - 4.4 VA N H Denotes 10 VAC Field Wiring Jumper SEAL LEAK A 16MN1A0 Control 50K Ohm Sensitivity, Inverse Operation. 1 8 7 3 4 5 6 SYS OK G TEST P/N DESCRIPTION 97897489 NEMA 4 ENCLOSURE, 115V, NO ALARM LIGHT. MODEL 810A Probe Sensing Circuit 1 VAC, 1.5 ma Run separate from motor leads. Denotes 1 VAC Field Wiring MOISTURE PROBES Date 4/18/11 LC-1 DETECTING MOISTURE - ALARM PILOT ON - SYSTEM OPERATIONAL PILOT OFF LC-1 NO MOISTURE - ALARM PILOT OFF - SYSTEM OPERATIONAL PILOT ON TEST BUTTON ACTIVE - ALARM PILOT OFF (RELAY ACTIVE) - SYSTEM OPERATIONAL PILOT ON PAGE A05

INSTALLATION AND OPERATING INSTRUCTIONS GENERAL: The type 810A is a conductance-actuated control for detecting moisture in the oil chamber of a submersible pump motor. It is used as a warning device to indicate a seal leakage and to signal the need for preventative maintenance. INSTALLATION: Mount control box vertically on wall or other solid structure and accomplish all indicated wiring. Terminals on the control are numbered and are in the same relative position as shown on the wiring diagram. Terminal pair 1- must be continuously energized from an A.C. supply line of electrical characteristics shown on the data plate. Contacts 8-6 and 8-7 are available for load duty, and if required, must be wired in series with the load device or devices; and that series branch circuit connected across a power source compatible with the load. Terminals 3-5 are connected to the moisture sensing probes in the motor marked W1-W via the cable provided with the motor. OPERATION: The oil surrounding the probes is nonconductive, and the control and seal leakage indicator light will be de-energized. An influx of moisture past the outer seal and into the oil reservoir will cause the relay to energize, and the seal leakage light will energize to indicate a seal leakage. Load contacts 8-6 and 8-7 will also change from their normally open or normally closed position when the control energizes. TEST PROCEDURE: A normally closed pushbutton and neon indicating lamp are provided as a part of the control for testing the moisture sensing relay. When the test pushbutton is depressed, the neon indicating lamp will be illuminated to simulate a seal leak: (A) power is supplied to the control (B) the control is operative (C) the wiring is intact To test the wiring from the relay to the moisture probes in the motor, de-energize and lock out power to the moisture relay. Use a multi-meter and measure the resistance between the relay connection points 3 and 5. Resistance should be greater than 300,000 ohms showing that the wiring from the relay to the moisture probes in the motor are intact. PAGE A06 Date 4/18/11

SUBMERSIBLE PUMP CONTROL SYSTEMS Yeomans offers a complete line of high quality pump control panels and integrated systems. From basic control panels to multipump integrated VFD systems, Yeomans has the experience to meet your job specific requirements. When reliable operation, low maintenance and "single source" responsibility are your objectives, specify Yeomans pumps and controls for your complete wastewater pumping package. A wide range of features and options is available, including but not limited to the following: Rugged Enclosures - NEMA 1, 3R, 4, 4X - Coated Steel - Stainless Steel - Fiberglass - Deadfront option Main Breaker Emergency Breaker Generator Receptacle Ammeters Voltmeter Phase Monitor Lightning Arrestors Surge Capacitors Power Factor Capacitors Reduced Voltage Starters Variable Frequency Drives Y-Delta Starters Level Control Devices - Float Switches - Submersible Level Transducers - Ultrasonic Level Controls - Bubbler Systems Level Indication Devices Intrinsically Safe Relays High / Low Low Level Alarm PLC Controllers Digital Operator Interfaces Back Up Control Systems Pump Start Delays Motor Protection Alarm Lights / Beacons Audible Alarm w/silence Button Automatic Dialers DC Alarm Systems Moisture Detection Relays Thermal Protection Relays Surge Protection Space Heaters Ventilation Devices Insulation Floor Mounting Stands Sun Shields Window Kits Junction Boxes Door Latches UL Listed Please contact Yeomans Pump or your local representative for further information and application engineering assistance. Date 9/1/07 PAGE A07