MapCHECK 3. The New Benchmark for 2D IMRT QA. Your Most Valuable QA and Dosimetry Tools

Similar documents
PROFILER Family IC PROFILER, IC PROFILER - MR & SRS PROFILER. Your Most Valuable QA and Dosimetry Tools

Product Solutions Your Most Valuable QA & Dosimetry Tools

YOUR MOST VALUABLE QA & DOSIMETRY TOOLS

Dual-Diode Dosimeter Patient Dose Monitor

LASER SOLUTIONS. Ensure Accurate Setup from Simulation to Treatment. FIXED: Micro // MOVABLE: CT Sim+

Monitoring of Radiation Exposure Adjacent to a Linear Accelerator Treatment Bunker with a Highlight Window

Victoreen & 660-8

Co-60 irradiator for therapy level calibrations at SSDLs

Characterization of dose impact on IMRT and VMAT from couch attenuation for two Varian couches

Assessment and management of radiotherapy beam intersections with the treatment couch

Independent validation of machine performance check for the Halcyon and TrueBeam linacs for daily quality assurance

Measuring Couch Motion Accuracy with X-ray Beam Fluence

An investigation of the reproducibility and usefulness of automatic couch motion in complex radiation therapy techniques

Dosimetric verification of intensity modulated radiation therapy

Ionisation Chambers Containing Boron as Neutron Detectors in Mixed Radiation Fields

Small-segment intensity modulated radiation therapy dosimetry with various ion detectors and Gafchromic EBT2 film

Competency: Critically evaluate the function of the ionisation chamber in the Linear Accelerator and its importance for correct treatment delivery

RAM GENE-1 ERK. Contamination & Radiation Meter. Operating Manual. Document #PRIR90N2.DOC Version 2.2 October 2009

May 2018 TALL PACKAGED PRODUCT INSPECTION. Discover what you've been missing DETECTION PERFECTION

SKF WireRace and inserted raceway bearings for weight savings and consistent friction torque

BUILD the clinic you ve always imagined.

ADVANCED SILICON DETECTORS FOR ELECTRON IMAGING & COUNTING

The Most Versatile Flame Detectors in the World. Optical Flame Detection Solutions

Aspirating Smoke Detection for Duct Monitoring

Uncertainty Assessment: Relative versus Absolute Point Dose Measurement for Patient Specific Quality Assurance in EBRT

Automated Infrared Thermography Complete Solutions from a Single Source

Environmental Radiation Monitoring System

REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF DEVICE (Amends In Its Entirety)

Technologies, Solutions, and Applications. Radiation-based Level

A FIRST RESPONDERS GUIDE TO PURCHASING RADIATION PAGERS

FLX380-30x FlexTester OTDR

PORTABLE ISOTOPE IDENTIFIER Search Tool / Sample Counting System

OptoYag M. clear vision

National Atomic Energy Commission ( NATEC ) Radiation Exposure and Laboratories General Directorate

The Most Versatile Flame Detectors in the World. Optical Flame Detection Solutions

FDR D-EVO II G35 FDR D-EVO II G43

AeroDR X30. Digital Mobile X-ray System

User Manual. Advanced Markus Chamber Ionization Chamber Type 34045

D3 Wireless temperature alarm & monitoring system family. tek-troniks

Diamond Detectors Ltd. Fabrication and Packaging Capabilities. Kevin Oliver

Urethral alarm probe for permanent prostate implants

Cemar Electro Inc. MAXX-606/607 Patient Positioning Laser. Installation and Set-up Manual

THEORY OR OPERATION 2 SENSOR UNIT - MECHANICAL 6 SENSOR UNIT - ELECTRICAL 8 CONTROL UNIT - MECHANICAL 9 CONTROL UNIT - ELECTRICAL 9 OPTIONS 11

REPUBLIC OF NAMIBIA MINISTRY OF HEALTH AND SOCIAL SERVICES REPORT BY: MS VERA UUSHONA TITLE: INSPECTION OF CONVENTIONAL DIAGNOSTIC X-RAY FACILITIES

INTERNATIONAL STANDARD

Ambulatory infusion pump for continuous, intermittent, TPN or PCA delivery.

RAM GENE / RAM GENE-1

INTERNATIONAL STANDARD

Beam Loss Position Monitoring with Optical Fibres at DELTA

MULTI-POINT DENSITY ARRAY FIXED-POINT INTERFACE PROFILING MEASUREMENT

Model ZXL User Manual

Provläsningsexemplar / Preview TECHNICAL REPORT. Nuclear medicine instrumentation Routine tests

XGLAB. X and Gamma Ray Electronics. Looking for new frontiers...

16S-Series 150W. In Vivo SPF Sunscreen Testing Solar Simulator

Gaseous detectors. 1

Generation and verification of QFix kvue Calypso-compatible couch top model for a dedicated stereotactic linear accelerator with FFF beams

HOMEPUMP ECLIPSE* Ambulatory Infusion System PATIENT INFORMATION

Fast. Precise. Versatile. UL Lighting Sciences

THE NEXT GENERATION IN VISIBILITY SENSORS OUTPERFORM BOTH TRADITIONAL TRANSMISSOMETERS AND FORWARD SCATTER SENSORS

Link loss measurement uncertainties: OTDR vs. light source power meter By EXFO s Systems Engineering and Research Team

Surface Concept Product Catalog 2014

INTERNATIONAL STANDARD

TIMS TIMS. Thermal Ionisation Mass Spectrometry.

Alaris Syringe module FAQs

Omnisens DITEST TM FIBER OPTIC DISTRIBUTED TEMPERATURE & STRAIN SENSING TECHNIQUE

OptoSLT M. preserve vision

Lecture-4. Soil Compaction. Dr. Attaullah Shah

NOTE: The color of the actual product may differ from the color pictured in this catalog due to printing limitation.

COMMISSIONING OF THE DOSE DELIVERY SYSTEM AT MEDAUSTRON

Ultra-Thin Flexible Heaters

clear & preserve vision OptoYag&SLT

25W Explosion Proof Surface Mount LED Light - C1D1-2 - C2D1-2 - Aluminum Frame V AC

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

Portable Instruments For First Response & In-Situ Analysis of Radiation

Customized MCPs for Analytical Instruments. An MCP for every application

CIRCA S-CATH CIRCA S-CATH. Product Code Description. Edge-to-Edge Coverage, better clinical decisions. Edge-to-Edge Coverage

INTERNATIONAL STANDARD

Sitron s CF Line of Flow Switch Monitors

RIID capability in the palm of your hand

Product Training Module: Basic Board Mount Pressure Sensors Uncompensated/Unamplified NBP Series

MODEL 23 AND 23-1 ELECTRONIC PERSONAL DOSIMETER. August 2017

WHITE PAPER FIBER OPTIC SENSING. Summary. Index. Introduction. About Fischer Connectors

gray Laser Power Detectors For fast and accurate measurements

MX1A and MX1B: Laser Displacement Detection Sensors. 85% to 110% of the rated voltage MX1A: 15VA, MX1B: 25VA

Kata products Kata DGM-1500 Turva

WHAT IS LASER ULTRASONIC TESTING?

CMT MANUAL 6. NMC SENSORS

ALLERGEN MIXING ASSISTANT

FT702LT Turbine control wind sensor gives durability a new meaning FT702LT. series

CPAPSolutions. Product Profile. Overview: The Family of SleepStyle TM CPAP Solutions

Catalytic Bead DrägerSensors for Fixed Gas Detectors

How SWIR Imaging contributes to the optimization of automatic quality control in the food industry

Radiation Monitoring Systems

Determination of the photon beam attenuation by the BrainLAB imaging couch: angular and field size dependence

ISO Acceptance tests for Nd:YAG laser beam welding machines Machines with optical fibre delivery Laser assembly

Reference Dosimetry of High-Energy Therapy Photon Beams with Ionisation Chambers. Recommendations No. 8, Revision 2018

Thermo Scientific Microm HM355S microtome

CASED HOLE SERVICES

PyroButton Catalog. Minimal configuration of PyroButton self-powered data-logger system:

Programat P510. Efficient firing performance. Excellent results. With infrared camera. The intelligent furnace

Transcription:

MapCHECK 3 The New Benchmark for 2D IMRT QA Your Most Valuable QA and Dosimetry Tools

THE NEW BENCHMARK FOR 2D IMRT QA The MapCHECK family is the world s most selected independent 2D measurement array, setting the standard for modern, efficient and stringent QA. Building upon this legacy, with MapCHECK 3 we ve continued to innovate by reducing the effects of volume averaging while providing high resolution 2D measurements. 1 I www.lightages.com 2 SUN NUCLEAR CORPORATION // sunnuclear.com

Ensuring Physician Prescriptions and Intended Doses are Accurately and Consistently Delivered to the Patient MapCHECK 3 is the next evolution in the MapCHECK familythe world s most chosen 2D array. MapCHECK 3 provides the highest detector density, smallest detector size, and largest field size of any 2D array for IMRT QA. Over 1,527 SunPoint 2 Diode Detectors measure only 0.48 mm each, and measure up to a 26 x 32 cm field. SNC Patient software allows rapid analysis of QA measurements against plan. INTRODUCING NEW SunPoint 2 Diode Detectors Smallest diode available Increased small field accuracy Patient Plan QA SNC Patient software allows rapid analysis of QA measurements against plan. SUN NUCLEAR CORPORATION // sunnuclear.com 3

MapCHECK 3 The New Benchmark for 2D IMRT QA Features and Benefits 2D patient plan QA Conventional IMRT and 3D conformal 1,527 SunPoint 2 Diode Detectors uniform throughout the array Smallest detector (0.007 mm 3 ) High sensitivity Less drift No dose volume average Field Size: 26 x 32 cm Real time electrometer measures every pulse with 50 ms updates Includes SNC Patient software Compare measured dose to planned dose with a single click Compare relative or absolute dose data using Distance-to-Agreement or Gamma Analysis Quick and reproducible isocentric measurements at any gantry angle with IMF or GMF 4 1 I www.lightages.com SUN NUCLEAR CORPORATION // sunnuclear.com

SNC Patient Software Simply import the QA files from your treatment planning system (TPS) and SNC Patient software compares the dose distribution of the treatment plan file to the actual measured values. Measured points that do not fit within the acceptance criteria are highlighted red for high dose and blue for low dose. Ease of Use Single power/data cable Manages all power and data in one connection Integrated electronics Self-contained with no separate electronics to set up Lightweight (5.6 kg) Patented user calibration Clinically proven Wide field Calibration is performed on site and does not require disassembly of the MapCHECK device No pre-irradiation or warm-up required for absolute dose measurements SUN NUCLEAR CORPORATION // sunnuclear.com 5

Accessories MapPHAN A water equivalent phantom that adapts any MapCHECK 3 for RapidArc, VMAT, and TomoTherapy. Setup time is fast and measurement may occur in coronal and sagittal orientations. Construction: Solid Water HE Available Depths (cm): 5.0, 10.0 Weight without MapCHECK 3: Area: (cm 2 ) 35.0 x 38.0 5 cm MapPHAN 8.0 kg 10 cm MapPHAN 21.0 kg IMF / GMF Measure at any gantry angle Fast, efficient, reproducible setup Measure at 100 cm SDD ± 0.5 mm Compatible with electron cones (GMF) Aluminum alloy construction Adjustable buildup clamps IMF pictured with MapCHECK 3 GMF 6 1 I www.lightages.com SUN NUCLEAR CORPORATION // sunnuclear.com

Specifications 7.07 mm Spacing, Entire Array 1527 Total Diodes 26 x 32 cm Array Size Power/Data Input Status Indicators Detector Type: Detector Quantity: 1527 Field Size (cm): 26 x 32 Array Geometry (cm): Detector Spacing (mm): 7.07 Active Detector Area (mm x mm): 0.48 x 0.48 Detector Sensitivity (nc/gy): 15 Sampling Frequency (ms): 50 Detector Stability: Dose Rate Dependence: Inherent Buildup (g/cm 2 ): 1.5 Inherent Backscatter (g/cm 2 ): 2.3 Radiation Measured: Number of Connection Cables: Dimensions (L/W/H): Weight (kg): 5.6 SunPoint 2 Diode Detectors Detector spacing parallel to X and Y axes: 1.0 Row spacing offset: 0.5 1%/ kgy at 6 MV +/- 1.5% over the range 100 MU/min to 1400 MU/min Photons: Co-60 to 25 MV Single power/data cable 56.0 cm x 29.2 cm x 2.9 cm System Requirements (SNC Patient, EPIDose) Operating System: Windows 7, Windows 8.1 MapCHECK 3 Compatibility Rotational Therapy: RapidArc, VMAT, TomoHelical IMRT, TomoDirect, 3D Conformal, Dynamic Wedge Treatment Planning Systems: Pinnacle, Eclipse, Monaco, iplan, RaySearch and any TPS system that can export DICOM data CPU: RAM: Hard Drive Space: FFF & non-fff Deliveries Recommended 2.4 GHz or better, multi core (2 or more cores) Recommended 4 GB or more Recommended 5 GB or more RapidArc and Eclipse are trademarks of Varian Medical Systems, Inc.; TomoTherapy, TomoHelical and TomoDirect are all trademarks and/or registered trademarks of Accuray Incorporated. Pinnacle is a trademark of Philips. Monoco and iplan are trademarks of Elekta AB. SUN NUCLEAR CORPORATION // sunnuclear.com 7

Corporate Headquarters 3275 Suntree Boulevard Melbourne, FL 32940 USA +1 321 259 6862 sunnuclear.com 2018 Sun Nuclear Corporation. All Rights Reserved. All data used is best available at time of publication. Data is subject to change without notice. MapCHECK3_032318