Document Code: 1 (13) Issuing date: Status:

Similar documents
Document Code: 1 (15) Issuing date: Status:

Document Code: 1 (5) Issuing date: Status:

Document code: 1 (10) Issuing date: Status:

CHAPTER 3 BASIC STEAM CYCLE

NFPA 85 COMPLIANCES OF BMS: A CASE STUDY OF BOILER CONTROL AT SBM OFFSHORE MALAYSIA COMPANY 1. AHMED ABOUELRISH 2 Universiti Teknologi Petronas

WHAT IS A BOILER? BOILER IS AN EQUIPMENT WHICH PRODUCES STEAM AT THE REQUIRED PRESSURE AND TEMPERATURE. BOILER DESIGN, MANUFACTURE & INSTALLATION ARE

Annex A-8 CONCENTRATED SOLAR POWER UNITS INDEX TO SYSTEM/COMPONENT CAUSE CODES

ANNEX A-1 GEOTHERMAL UNITS INDEX TO SYSTEM/COMPONENT CAUSE CODES BOILER BALANCE OF PLANT STEAM TURBINE GENERATOR MISCELLANEOUS - GEOTHERMAL EXTERNAL

Solution of I Mid Term Steam Engineering 6ME5A

When you complete this module you will be able to: Describe various watertube boiler designs, including large generating units.

BHEL Steam Generators Material Selection Overview by Veerendar Aluvala DM/BHEL/Trichy

2x58 MW Coal Fired Power Plant at Mauritius

Efficient Steam System Design

Q - Series Boiler. Troubleshooting Manual

Yarway Narvik Steam Desuperheater Series 4300 TempLow

Boiler drum level controller using Microcontroller

Tuesday, 18 November Video Links. Oil Blow Through 13 November BLOW THROUGH ON BOILER UNIT 6 BEGINS.

DIRECTIVE NO: D-B

Boiler Technical Specifications (2013)

On-Load Boiler Cleaning with Steam

MODEL ANSWER FOR ELEMENTS OF MECH.ENGG.(17413) 1) steam boiler- It is a closed vessel in which steam is produced from water by combustion of fuel.

A FREAK INCIDENT OF A BED SUPERHEATER FAILURE

MILL IN SERVICE FIRST COAL FIRES AT MEDUPI

CONTROLLING BOILER SWELL AND SHRINK

What to Expect from Your EtaPRO Investment

SULPHUR RECOVERY UNIT

PESIT-Bangalore South Campus

RECOMMENDED GOOD PRACTICE

ENERGY RECOVERY SOLUTIONS. Recover wasted energy to increase efficiency and save money immediately.

Sootblowers. Learning Outcome. Learning Objectives. When you complete this module you will be able to: Discuss sootblowers.

CONSIDERATIONS IN CONVERTING A DUAL SHELL OR A DUAL PRESSURE COAL FIRED PLANT CONDENSER INTO A COMBINED CYCLE PLANT CONDENSER

Maintenance 50 Serie CAUTION. Before resetting your electronic card that displays an error code. OVERHEAT MESSAGE

ASSSIGNMENT 3. Textbook Assignment: Boilers, chapter 4, pages 4-1 through 4-15, and Steam Turbines, chapter 5, pages 5-1 through 5-1.

BOILER 3CL LUNARIO 3CL MACARUBBO 3CL SAGAYO 3CL LUMIGUEN 3CL MIRADOR

Study and Design Considerations of HRSG Evaporators in Fast Start Combined Cycle Plants. Govind Rengarajan, P.E.CEM, Dan Taylor

STEAM & POWER ENGINEERS

G615/11 Cast Iron Boiler

ecodry Figure 1 - Process Diagram ecodry B General Process Description

WATER TUBE SOLID FUEL SERIES YOSHIMINE CO., LTD

Attention is drawn to the following places, which may be of interest for search:

OPTIMISATION OF SOOT BLOWER OPERATION IN BOILER TO IMPROVE EFFICIENCNY

Boiler Basics. Design and operation

Improving Boiler Stability Through Advanced Regulatory Control

Boiler Light-up. Kumar Rupesh Date: 03-Sep-13

Appendix B9 Geothermal Unit Cause Codes

Economical and simplified solutions that offer quality and optimum steam trap service.

NEW LINE BOILER CONTROLLERS

AUTOMATION OF BOILERS USING LABVIEW

A Newsletter published by. for Industrial Steam and Power Users

Corn Flame Energy Corn Stove Model 3000

Cold Weather Preparedness Plant Winterization Lessons Learned & Best Practices

INSTALLATION, OPERATION AND MAINTENANCE. Ariterm Hybrid 20


G315/6 Cast Iron Boiler

Foster Wheeler Condensers and Feedwater Heaters. High Quality Steam Components

Electronic pellet burner controller - NPBC-V3M. Electronic Pellet Burner Controller NPBC-V3M

Condensate Recovery and Return System SDR A

Boiler. Fire tube Boiler:

G315/5 Cast Iron Boiler

OPERATION MANUAL RK-2006LPP AUGER FITTED SOLID FUEL BOILER TEMPERATURE CONTROLLER. Version DC19

Series 300 VTB. Installation Instructions

Steam Fundamentals. (in heating & processing applications)

KITURAMI Wood PELLET BOILER. User s Manual - KRP-20A

ASPHALT DRUM MIX PLANT - MDM 25 (20-30 TPH) I TECHNICAL SPECIFICATIONS COLD AGGREGATE FEEDER

Ohio Energy. Workshop HH. Strategies & Technologies to Improve the Boiler Room Efficiency. Wednesday, February 21, p.m. to 3:15 p.m.

G515/7 Cast Iron Boiler

Electronic Pellet Burner Controller NPBC-V3M

A-8-01 Typical questions and answers on the boiler specifications on tender and boiler contract documents

YARWAY NON-REPAIRABLE DRIP AND TRACER STEAM TRAPS SERIES PB, 29, 129Y AND 29S

Aqua Balance. AquaBalance TM CONTROL MODULE QUICK START GUIDE LEGEND

ASPHALT DRUM MIX PLANT - MDM 25 (20-30 TPH) I TECHNICAL SPECIFICATIONS COLD AGGREGATE FEEDER. Gathering cum slinger conveyor 500 mm x 7.

Eclipse Self-Check UV Scanner

SURGING AND BLOW OUT OF LOOP SEALS IN A CFBC BOILER. By K.K.Parthiban Venus energy audit system

B.Tech. First Semester Examination Basics of Mechanical Engineering (ME-101F)

Trade of Plumbing. Module 2: Domestic Hot and Cold Water Service Unit 10: Hot Water Supply Phase 2

DM 45 (40-60 TPH) ASPHALT DRUM MIX PLANT - DM 50 (60-90 TPH) I TECHNICAL SPECIFICATIONS DM 60 ( TPH) COLD AGGREGATE FEEDER.

Modification of Condenser Nozzle and Cooling Tower Exit Screen to Increase Condenser Performance

TEPZZ 87_ 6A_T EP A1 (19) (11) EP A1 (12) EUROPEAN PATENT APPLICATION

AIM OF THE EXPERIMENT:- Study of boilers (fire tube, water tube) APPARATUS REQUIRED: - SL.NO NAME OF THE APPARATUS SPECIFICATION QUANTITY 01 Fire tube

CHP-turbine room. CHP can capture almost EXTRACTED STEAM 20 PSI HIGH-PRESSURE STEAM 1250 PSI HEAT EXCHANGER HOT WATER SUPPLY F

POWDER GUIDE. Trouble shooting tips to maximise the benefits of Apcoshield Powder Coatings

Revised and extended by Nick May

Operating Instructions Manual Janfire NH/Integral Pellets Burner with External Auger

Efficiency and Design Improvements in Multiple Hearth & Fluid Bed Incinerators

THERMAL ENGINEERING & GAS DYNAMICS ME-6002

DIVISION FINNED WATER-TUBE WATER HEATERS

Steam Ancillary Equipment. Primary Steam System, Water Treatment and Auxiliary Steam System Equipment

A CASE STUDY ON BOILER TUBE FAILURE AT JPL

Presentation On Industrial Boiler Operation And Maintenance

Boiler Mountings. Engr. Omar Sadath, Maritme Lecturer & Trainer, Bangladesh

Power Flame Incorporated

HEAT GENERATION 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS. B. Section HVAC Basic Materials and Methods

Marine Boilers. From a world class boiler manufacturer

BOILERS CHAPTER 4. Fireroom The fireroom is a compartment containing boilers and the operating station for firing the boilers.

LATTNER BOILER COMPANY 9.5 HP Low-NOx Installation and Start-Up Checklist for Dry Cleaners

Boiler Basics: Design & Application Differences. Presented by Steve Connor July 30, 2014

INSTALLATION AND OPERATION MANUAL FOR 2 STAGE RIELLO BURNER ADDENDUM TO ( Mo 437 manual )

CHAPTER 2: PROPERTIES OF STEAM AND STEAM POWER

Typical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000

ENERVEX VHX VORTEX HEAT RECOVERY CENTER

Transcription:

Document Code: 1 (13) Project : MULTI FUEL CFB BOILER SIMULATOR Author: Approved: Language: JJA Document title: SYSTEM DESCRIPTION REHEAT STEAM SYSTEM Submitted for: Customer reference: Other information:

Document Code: 2 (13) TABLE OF CONTENTS 1 GENERAL...3 2 DESIGN DATA...3 2.1 Reheat steam values...3 2.2 Pressure drops...4 2.3 Steam temp. control range...4 3 EQUIPMENT DATA...4 3.1 Reheater tube bundles...4 3.2 Reheater headers...5 3.3 Reheater IA by-pass valve...5 3.4 Desuperheaters...6 3.5 Valves for desuperheaters...6 3.6 Safety/Start up valves S1 LBB10 AA401/402...7 3.7 LP-by-pass valve...8 3.8 Silencers...8 4 AUTOMATION AND INSTRUMENTATION...9 4.1 Reheater pressure control...9 4.2 Reheater temperature control...9 5 OPERATION...10 5.1 Preliminary checks prior to start up...10 5.2 Boiler start up...11 5.3 Normal operation...11 5.4 Shut down...12 5.5 Operating Disturbances...12 5.5.1 High Steam Temperatures...12 5.5.2 Tube leakage...12 5.6 Power failure...13 6 CONNECTED SYSTEMS...13 7 APPENDICES... 13

Document Code: 3 (13) 1 GENERAL The boiler is furnished with reheaters, where the steam is reheated to improve cycle efficiency after high pressure part of the steam turbine. Reheater system increase boiler LP steam, which is turbine s IP-steam (IP = IntermediatePressure), temperature after turbine HPcasing. After reheater steam is lead to turbine IP-casing. Steam from the pressure reduction valve after superheater IV is taken to the inlet of the reheater I. The valves are arranged so that the pressure reduction station (S1 LBH10/20 AA201) controls boiler HP steam pressure, but functioning also as a safety valves of the HP steam system (in the cold reheater line). Hot reheat steam system has two safety valves, which functions also as pressure controlling device s. Hot reheat system valves blow first and therefore in some operation situations HP pressure station valves can be maintain closed. These valves are used for regulating the boiler pressure especially during start ups (or shut down). The start-up steam line is led to atmosphere trough a silencer. The reheat steam enters to reheater IA, which is of similar construction to superheater I and located in the back pass of the boiler after SH II. Reheater IB is after SH I. Reheat steam temperature is maintained at design value typically over load range 60 100 % of MCR. Compared with feed water spray control by-pass control gives higher plant efficiency. Final reheating takes place in reheater II, which is similar in construction to Intrex superheaters and is located in the return leg. All superheaters and reheaters are fully drainable. 2 DESIGN DATA 2.1 Reheat steam values Pressure bar(g) 33 Flow kg/s 98,5 Temperature C 563

Document Code: 4 (13) 2.2 Pressure drops Low pressure side Turbine to hot reheat pipe bar 4,4 2.3 Steam temp. control range Steam temperature is controlled to 563 C boiler load range at 67 113 kg/s. 3 EQUIPMENT DATA 3.1 Reheater tube bundles The boiler is equipped with two reheaters where RH I is divided to two and RH II is Intrex type. Reheater I is counter current flow type located in back pass. Reheater II is located in return leg. Reheaters are connected according to the Reheat Steam P&I-diagram. Reheater I A Tube type bare tube Arrangement in line Tube size mm 44,5 x 4,0 s 13CrMo44 (50 %) 7CrMoVTiB1010 (50 %) Reheater I B Tube type bare tube Arrangement in line Tube size mm 38,0 x 4,0 s 7CrMoVTiB1010 Reheater II Tube type Intrex Arrangement in line Tube size mm 63,5 x 8,0 s SA213TP347HFG

Document Code: 5 (13) 3.2 Reheater headers Reheater I A Inlet header Size mm 610,0 x 30,0 15Mo3 Outlet header Size mm 660,0 x 25,0 X10CrMoVNb91 Reheater I B Inlet header Size mm 711,0 x 30,0 13CrMo44 Soot blower Nozzle Size mm 114,3 x 10,0 10CrMo910 Outlet header Size mm 813,0 x 36,0 X10CrMoVNb91 Reheater II Inlet header Size mm 711,0 x 30,0 X10CrMoVNb91 Outlet header Size mm 813,0 x 65,0 X10CrMoVNb91 3.3 Reheater IA by-pass valve KSB Type CV Size DN 500 Actuator Aumatic

Document Code: 6 (13) 3.4 Desuperheaters System have three spray type desuperheaters for controlling of the steam temperature. Feed water is used for spraying. Dereheater I / Spray water I Size mm 610,0 x 20,0 X10CrMoVNb91 Dereheater II / Spray water II Size mm 610 x 20,0 X10CrMoVNb91 3.5 Valves for desuperheaters Main line close valve S1 LAE09 AA101 KSB Type GT Size DN 80 Actuator Aumatic Dereheater I / II spray water hand valves S1 LAF05/10 AA001 KSB Type GL Size DN 40 Dereheater I / II spray water motor valves S1 LAF05/10 AA101 KSB Type GL Size DN 40 Actuator Aumatic

Document Code: 7 (13) Desuperheater I / II spray water control valve S1 LAF05/10 AA201 KSB Type CV Size DN 40 Actuator Aumatic Flow meter desuperheater I /II S1 LAF05/10 CF201 Flowhow Type ISA-Nozzle Size mm 48,3 x 7,1 3.6 Safety/Start up valves S1 LBB10 AA401/402 The function of the Reheater safety valves is to protect the reheater against overpressure. The capacity of the Reheater safety valves is equal to the outlet capacity of the HP bypass stations. The pressure impulses are taken from the cold reheat pipe (1pc.) and hot reheat pipe (2pcs.). The HP bypass stations are equipped with a control function acting at lower pressure than the safety function. Number of units: % 2 x 50 Capacity: kg/s 2 x 57,5 Pressure set values: Mechanical design pressure (cold and hot reheat) bar(g) 50 Cold reheat: Safety function bar(g) 50 Normal operating pressure bar(g) 37 Hot reheat: Safety function bar(g) 43 Safety valve closing*) bar(g) 40,8 Control set pressure**) bar(g) 40 LP bypass station opening bar(g) 36 (see: LP bypass station) Normal operating pressure bar(g) 33 *) Safety valve closing to be checked with valve manufacturer (assumed 95% of opening pressure). **) LP-bypass opening pressure set value + 4 6 bar. To be checked during commissioning.

Document Code: 8 (13) 3.7 LP-by-pass valve Number of units: 1 Capacity kg/s 1 x 50,6 Pressure set value Design pressure bar(g) 50 Control set pressure*) bar(g) 36 Normal operating pressure bar(g) 33 Safety function close bar(g) 0,39 (condenser pressure)**) *) To be checked during commissioning. **) The LP bypass station will also be closed if the maximum allowable temperature in the condenser 80 C is exceeded. 3.8 Silencers Material Foster Wheeler Stainless steel

Document Code: 9 (13) 4 AUTOMATION AND INSTRUMENTATION In this section automation is explained only basic level and more detailed descriptions can be found in Automation Descriptions. 4.1 Reheater pressure control Normal operation function of the LP bypass station is to bypass the IP/LP-turbine. The LP bypass station is used in start-up and house load operation of the power plant and during a steam turbine trip. The LP bypass station also controls the reheater pressure so, that the maximum allowed pressure or rate of pressure increase 2 bar/min is not exceeded. Reheater steam pressure is managed by turbine IP-steam system and LP-bypass valve is closed. If LP-by-pass is not capable to maintain pressure, start-up/safety valves will open. Before safety action, valves work as pressure controlled start-up valves. 4.2 Reheater temperature control Reheating is controlled by a RH IA by-pass valve, this means that at full load part of steam bypasses reheater IA and regulates the outlet steam temperature after reheater IB. Reheaters are equipped two spray desuperheaters one after RH IA and one after RH IB, so the end temperature after reheat II is controlled with desuperheater after RH IB.

Document Code: 10 (13) 5 OPERATION 5.1 Preliminary checks prior to start up Action by Control room operator and Auxiliary Operator Verify that: Reheater drain valves are open Reheater IA, IB, II inlet and II outlet motor operated drain valve are available Reheater vent valves are open Reheated steam line drain valves are open HP bypass drain line steam traps is open Start up isolation/check valve is open Start up valve is open 30 100 %, if boiler has no pressure. If boiler has a pressure, set start up valve(s) to position of a minimum steam flow required to cool superheaters. Open desuperheating line check valves Desuperheating control valves are operative All safety valve plugs are removed Safety valves are in proper operating conditions Hydraulic units for safety and HP bypass valves are available Action by Auxiliary Operator Walk down the boiler to verify that: Silencers are operative (free from foreign parts or covers and drains are in operation) Reheater doors are closed Check for any leaks before proceeding All auxiliary equipment must be in first-class operating condition and operated according to manufacturer's recommendations and instructions. All pressure indicator valves are open. Ensure locally, that safety / start up valves are in proper condition for operation

Document Code: 11 (13) 5.2 Boiler start up Starting a boiler with no pressure and a turbine with metal temperatures below 200 C is considered a cold start up. Action by Control Room Operator and Auxiliary Operator Start hydraulic units for safety and HP bypass valves Set standby pumps of hydraulic units in sequence-mode When igniting the first burner, open HP bypass valves and the start up valves to 30 100 % to maintain a flow through the reheaters During boiler warm up, reheater flue gas temperatures must be limited to the maximum allowable reheater metal temperature Note: Avoid increasing fuel flow at too fast a rate, since any excess steam is exhausted to waste through the start up valve. When boiler pressure reaches 1,5 2,0 bar, close the boiler drum, superheater, reheater and main steam line vent valves Close superheater and reheater drain valves open until boiler pressure reaches 8 12 bar (when it can be ensured that steam is at least 20 C superheated). Monitor feed-, boiler water and steam chemistry continuously Steam temperature after the HP bypass valves is controlled according start up curve As the LP bypass valve opens (when condenser has vacuum), the start up valve closes. 5.3 Normal operation Monitor reheat superheater material temperatures. See also superheaters temp. diagram. Check, that spray water controlling works proper. Monitor the steam temp. Monitor the steam pressure. Reheater steam pressure will vary with turbine load In normal operation the boiler fuel control can be operated in one of two modes: a) The control set point is main steam pressure. Fuel flow is varied to maintain the set point, set by operator, operating the controller in Auto-mode or b) The control set point is the electrical load supplied to the grid. Fuel flow is varied to anticipate a change in steam flow resulting from a change in demand of the grid. As the boiler pressure starts to change as a result of the change in fuel flow, the turbine loads varies to keep the boiler pressure steady. Steam pressure control is in Sequence-mode In the case of reheater pressure surges, in order to limit reheater pressure, check the reheater pressure controller mode and set pressure and also function of safety valves.

Document Code: 12 (13) 5.4 Shut down Shut down the boiler and check that spray water valves are not leaking. 5.5 Operating Disturbances 5.5.1 High Steam Temperatures High steam temperatures can be caused by insufficient spray water due to a faulty control valve or plugging due to poor feed water quality. The cause should be traced and rectified. It is possible to use the manual bypass valve until the control valve is fixed. 5.5.2 Tube leakage If a major leak occurs - burst of a tube - during operation, the combustion chamber pressure may rise due to the increase in flow caused by the sudden evaporation to steam. Operator judgement must be used to assess the seriousness of the failure and to decide whether an emergency or normal shut down should be performed. Should such a burst occur the ID fan flow should be increased and fuel flow stopped. At the same time steps should be taken to reduce the boiler pressure immediately with the start-up (or turbine by-pass) valve. Feed water should be brought to the boiler so, that the boiler parts do not overheat and only stopped when the flue gas temperatures have dropped below 400 ºC. Keep the drum level at minimum. If the water level has been completely lost, do not bring cold feed water to a hot drum max. allowed difference ~ 50 ºC. Check the feed water temperature after economiser. Secondary air flow can be reduced but not completely stopped, while there is still combustible material in the gases. Primary air for fluidising should be stopped, if the leakage is big. This will stop the burning at once in the bed. Otherwise primary air for fluidising can be kept at minimum flow until all the remaining fuel in the bed has burnt completely, and it helps also to get the rest of the bed ash away from the grid. Remove bed material via the ash cooler, if the leakage is entering the bed. Check, that (small amounts of) unburned fuel will not start to burn at the ash conveyors causing a fire.

Document Code: 13 (13) For smaller leakages follow normal shut down procedures. Secondary air flow can be reduced but not completely stopped, while there is still combustible material in the gases. Primary air for fluidising can be kept at minimum flow until all the remaining fuel in the bed has burnt completely. Remove bed material via the ash cooler, if the leakage is entering the bed. Try to determine the approximate location of the leakage by walking round the boiler. An economiser leak may be detectable by sound or by an increase in make-up water requirements. Note, that water leaks can lead to erosion of adjacent tubes and may cause plugging of ash hoppers and air heaters. Steam leaks in superheaters can cause considerable damage to adjacent tubes due to steam cutting. Operator judgement must be used to assess the seriousness of the failure and to decide whether an emergency or normal shut down should be performed. Monitor the leakage rate and cooling down rate. 5.6 Power failure When a power failure occurs, the boiler shuts down. Most important devices to control the boiler to secured situation are secured by the emergency electricity supply. 6 CONNECTED SYSTEMS Superheater steam system Feed water system HP-steam system Soot blower system Drains Vents Sampling Blow down system S1 HAH_-MFB0001 S1 LA -MFB1001 S1 LB -MFB1001 S1 HCB_-MFB0001 S1 HAN_-MFB0002 S1 HAN_-MFB0003 S1 QU -MFB1001 S1 HAN_-MFB0001 7 APPENDICES Control- and logic diagrams Pressure raising diagram.