Core identification code. J-YY...BD Indoor Cable. J-YY...BD Indoor Cable. VDE 0815 Mutual capacitance. J-YY...BD Indoor Cable. Cu conductor 0.

Similar documents
Flame Retardant Overall Screened Instrumentation Cables (multicore)

Caledonian Flame Retardant Coaxial Cables

Multi-Core Fire Resistant Cable

Note: Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC compound and the cable design.

Catalogue Telecommunication Cables INTRODUCCIÓN

High Performance LSZH Fire Resistant Cable

SPECIAL ELECTRICAL AND OPTICAL CABLES

Telecommunication Cables

Caledonian Fire resistant Coaxial Cables

CABLES FOR ALARM AND SAFETY SYSTEMS

HELKAMA. Optical Fibre Cables

600/1000V XLPE Insulated, LSZH Sheathed, Double steel tape Armoured Power Cables (3 Cores)

IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission

IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission

600/1000V SR Insulated Flexibles Control Cables (2-4 Cores & Multicores)

Firecel Safety Cables

Optical Fibre Cable Technical Specification. Duct Cable GYTA-72B1.3

FIRE RESISTANT CABLES

IEC UNE DESIGN. 1. Conductor. 2. Insulation. Cross-linked polyethylene (XLPE) 3. Outer sheath. Flexible PVC, black colour.

PRODUCT CATALOGUE Norröna

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Caledonian fire Resistant signal & Data cables

THE INNOVATIVE CABLE PRODUCER INSTRUMENTATION CABLES FOR THE INDUSTRY - AND PLANT CONSTRUCTION

The Quality Connection. BETAflam Fire Resistant Safety Cables

Duct Cable GYTS-144B1.3

INTERNATIONAL STANDARD

Catalogue Power Cables

Copper LAN cable. This specification describes the general requirements for AMP NETCONNECT* copper LAN cable.

BS EN :2004. Test On Electric And Optical Fibre Cables Under Fire Conditions. WF Report Number. Date: 14 th November 2008.

Power Cables. Introduction 3 RV 4 RVMV 5 RVSV 6 RVFV 7. ELECWIRES 2 Page

Special Provision No. 683S28 December 2017

Introduction.

Compact Module. Category 6A FTP Cabling System 1.1

Firetuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red

S Low loss coax cables with foamed PE

SAS Security and Alarm Safety Cables

PRAKAB PRAŽSKÁ KABELOVNA, s.r.o. COMPANY PROFILE 2015

MEDIUM VOLTAGE CABLES INSTRUMENTATION CABLES RUBBER CABLES FIRE RESISTANT CABLES

INTRODUCTION. Our diverse range of world-class Specialty Insulated Wires and Cablesinclude: LV Cables -

CORFLEX. TYPE MC-HL & MV-105 or MC-HL OIL & GAS CABLES

CORFLEX TYPE MC-HL POWER, CONTROL & INSTRUMENTATION CABLES

Traction Cable Radox 3 GKW

Double insulated, electron-beam cross-linked, halogen free photovoltaic wire sunlight resistant. Single conductor, flame retardant insulation.

Cable technology for highest safety requirements

600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (Multicore)

Firetuf Cables ZERO HALOGEN, LOW SMOKE (0HLS ) CABLE

System Circuit integrity in the event of fire. Safety cables and systems from a pro. Cabling Solutions

Firetuf Cables ZERO HALOGEN, LOW SMOKE (0HLS ) CABLE

CATEGORY 6A FTP RJ45 SOLUTION

CABLE SOLUTION FOR THE RAILWAY Telecommunication and signalling cables

Agencavi Srl has been specializing in the distribution of special cables and accessories for industrial automation since 1983.

Fire alarm cables. for highest safety requirements TRADITION INNOVATION PASSION

Firetuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red

Catalogue. Instrumentation & Control Cables

Havells Fire Survival Cables

2016 CDM Smith All Rights Reserved July 2016 SECTION FIBER OPTIC DATA NETWORK

4120 Fire Alarm Network Reference

Data sheet OpDAT universal cable 1x24 OM4 - bend insensitive

CONTENTS. Introduction Customer Service BS codes of practice BS Fire Performance Cable Selection Guide... 7

FIRE PERFORMANCE CABLE

INTERIM EUROPEAN I-ETS TELECOMMUNICATION June 1997 STANDARD

ENHANCED FIRE PERFORMANCE CABLE

(Notices) EUROPEAN COMMISSION

AFIREFENIX SZ1-K 0,6/1 kv PH120 (AS+)

Easy to install in ducts, tunnels and trenches by means of compressed air or pulling wire. Suitable for direct burial (crush 400 N/cm).

Data sheet OpDAT breakout cable 12x1 OM4 - bend insensitive, class Dca s1 d1 a1

Tether and Umbilical Cables for Remotely Operated Vehicles

Table of Contents. TELE-FONIKA KABLE SA (DMCC Branch). 4 TELE-FONIKA Kable Group 6 FLAME-X 950 SERIES 1 11 FLAME-X 950 SERIES 2

13. UNITED KINGDOM Standards Supply Voltage and Plug Configurations 247

Shipboard & Offshore Cables

Method of test defined in IEC for determining the circuit integrity performance of a cable under fire conditions.

TELECOM SOLUTIONS CABLE CATALOGUE INNOVATIVE FIBRE OPTIC CABLE SOLUTIONS

OPTICAL. Micromodule DW About Us. > IEC nd Ed. According to. > EN nd Ed. FTTx

Data sheet OpDAT mini breakout cable 24x1 OM4 - bend insensitive

GUCN. Central Loose Tube Cables Universal Indoor / Outdoor - Corrugated Steel Tape Armor (CST) A/I-DQ(ZN)(SR)H Full Rodent Protection v13.

FIBRE OPTIC COMMUNICATION CABLES, IN DUCTS - Item No. FIBRE OPTIC COMMUNICATION CABLES, IN DUCTS (TEMPORARY) - Item No.

GUARDIANTM QUALITY APPROVED CABLES. Cables Limited MADE IN IRELAND SINCE 1934 IDH CABLES LIMITED MECHANICALLY PROTECTED CABLES

CAT5E DIRECT BURIAL (FLOODED CORE) 24AWG, UTP, 4 PAIR, SOLID 1000 PULL BOX /CMXF

LV FIRE RESISTANT CABLES

Ø 1000 * 588 mm 50 kg

INSTRUCTION DE IS 23 SÉCURITÉ Rev. 2 SAFETY INSTRUCTION

Overmoulded Cable Assembly Selector Guide

Wire and Cable. For more information on these Tyco Electronics products, visit the following website:

OIL & GAS INDUSTRY OTHER INDUSTRIES

Flame Retardant EP/CPE POWER, CONTROL & INSTRUMENTATION CABLES

AirUnit. Installation instructions. mfh systems modern floor heating. Decentralised domestic ventilation

GCRG. Multi Loose Tube Cables Universal Indoor / Outdoor A/I-DQ(ZN)BH Improved Rodent Protection v7.0. Ordering Information.

Tether and Umbilical Cables for Remotely Operated Vehicles

Author Owner Issue Authority Name: Gordon MacKenzie Title: Senior Engineer Engineering Design and Standards

CORRIGENDA. (Publication of titles and references of harmonised standards under Union harmonisation legislation)

THE MYSORE UNIT OF RPG CABLES MANUFACTURES A RANGE OF INSTRUMENTATION CABLES

SECTION LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES (600 VOLTS AND BELOW)

Single core cables with reduced wall thickness

(Publication of titles and references of harmonised standards under Union harmonisation legislation) (Text with EEA relevance) (2017/C 298/02)

fire resistant cables


DNVGL-CP-0402 Edition February 2016

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 28 ELEC. SAFETY & SECURITY SECTION CONDUCTORS AND CABLES FOR ELECTRONIC SAFETY AND SECURITY

Multipurpose Cables (indoor/outdoor), Multipurpose central tube cable (maxibundle) with glass yarn armouring A-DQ(BN)H 4-24

DNVGL-CP-0399 Edition March 2016

Transcription:

Indoor cables J-YY...BD Indoor J-Y(ST)Y..LG Indoor Comparable products UNITRONIC J-2Y(ST)Y...ST III BD see page 271 Indoor telephone cables transmit analogue or digital signals In news and communication technology, the following connections can be installed: telephone, telefax, telex as well as standard modems of postal services, burglar and fire alarm systems (cf. fire alarm cables), communication and paging systems, access control, time and data control systems Can be used in dry and wet interiors for fixed installation on and under plaster J-YY...BD Indoor Flame-retardant acc. to IEC 60332-1-2 J-Y(ST)Y..LG Indoor Flame retardant according IEC 60332-1-2 J-YY...BD Indoor See table T10 Approvals J-YY...BD Indoor VDE 0815 J-YY...BD Indoor Max. 100 nf/km Max. 100 nf/km J-YY...BD Indoor > 100 MOhm x km J-YY...BD Indoor (800 Hz): K1:80%<=300pF/100m (800 Hz): K1:80%<=300pF/100m Conductor cross-section in J-YY...BD Indoor Cu conductor 0.6mm: 0.28 mm² Cu conductor 0.8mm: 0.50 mm² attenuation / attenuation J-YY...BD Indoor 1.5 db/km J-Y(ST)Y..LG Indoor 1.7 db/km 1.1 db/km max. 73.2 Ohm/km J-YY...BD Indoor fixed installation: -30 C to +70 C Use/application for stationary installation on or under plaster in dry and damp interiors J-YY...BD Indoor PVC based core insulation Four cores twisted as star quad PVC based outer sheath Colour: pebble grey (RAL 7032) J-Y(ST)Y..LG Indoor Like J-YY...BD, but cores are twisted in pairs, foil wrapping, static aluminium laminated plastic foil with copper drain wire over cable core, PVC-based outer sheath Colour: pebble grey (RAL 7032) Part number Number of double cores Number of star quads Outer diameter J-YY...BD Copper conductor 0,6 mm 1591700 2 1 5.0 11.0 35.0 1591701 4 2 6.5 23.0 60.0 1591702 6 3 7.0 34.0 75.0 1591703 10 5 8.5 57.0 110.0 1591705 20 10 11.0 113.0 200.0 1591707 30 15 13.5 170.0 285.0 1591709 50 25 16.5 283.0 450.0 1591712 100 50 22.5 565.0 850.0 J-Y(ST)Y...LG Copper conductor 0,6 mm 1591300 1-6.9 6.9 30.0 1591301 2 1 5.5 13.0 40.0 1591302 3-18.0 18.0 50.0 1591303 4-24.0 24.0 60.0 1591304 5-30.0 30.0 70.0 1591305 6-35.0 35.0 80.0 1591306 8-46.0 46.0 90.0 1591307 10-58.0 58.0 110.0 1591308 12-71.0 71.0 130.0 1591310 16-93.0 93.0 160.0 1591311 20-116.0 116.0 190.0 1591312 24-139.0 139.0 220.0 1591313 30-172.0 172.0 280.0 269

Indoor cables Part number Number of double cores Number of star quads Outer diameter J-Y(ST)Y...LG Copper conductor 0,6 mm 1591314 40-229.0 229.0 350.0 1591315 50-286.0 286.0 430.0 1591316 60-342.0 342.0 500.0 1591318 100-568.0 568.0 850.0 J-Y(ST)Y...LG Copper conductor 0,8 mm 1591500 1-11.0 11.0 40.0 1591501 2 1 7.0 21.0 60.0 1591502 3-31.0 31.0 80.0 1591503 4-41.0 41.0 100.0 1591504 5-52.0 52.0 120.0 1591505 6-62.0 62.0 140.0 1591506 8-82.0 82.0 170.0 1591507 10-102.0 102.0 220.0 1591508 12-123.0 123.0 250.0 1591510 16-164.0 164.0 320.0 1591511 20-204.0 204.0 380.0 1591512 24-244.0 244.0 460.0 1591513 30-304.0 304.0 560.0 1591514 40-405.0 405.0 710.0 1591515 50-506.0 506.0 900.0 1591516 60-606.0 606.0 1,050.0 1591517 100-1,008.0 1,008.0 1,750.0 Copper price basis: EUR 150 / 100 kg Accessories Universal strip stripping and cutting tool see page 823 STAR STRIP stripping tool see page 824 J-Y(ST)Y...LG Fire Alarm Info Installation cable with the red outer sheat in accordance with VDE 0815 The cable is marked Fire alarm cable at regular intervals on the sheath. It is therefore particularly suitable for installation in modern-type fire alarm systems. These installation cables are used for signal transmission in static systems on and under plaster in dry and wet interiors and for outdoor use. The 2-paired versions = star-quad cable design Flame-retardant acc. to IEC 60332-1-2 Single wire conductor of plain copper wire PVC based core insulation Cores twisted in pairs, pairs twisted together, foil wrapping over cable core, static screen of aluminium-laminated plastic film with copper drain wire PVC based outer sheath Colour: flame red (RAL 3000) In accordance with VDE 0815, see T 10 VDE 0815 Fixed installation fixed installation: -40 C to +70 C Use/application for stationary installation on or under plaster in dry and damp interiors and for outdoors. Part number Number of pairs and conductor diameter, mm Outer diameter J-Y(ST)Y...LG red 1708001 1 x 2 x 0.8 6.0 11.0 40.0 1708002 2 x 2 x 0.8 7.0 21.0 60.0 1708004 4 x 2 x 0.8 9.0 41.0 100.0 1708006 6 x 2 x 0.8 10.5 62.0 140.0 1708010 10 x 2 x 0.8 13.5 102.0 220.0 1708020 20 x 2 x 0.8 16.5 204.0 380.0 270

Indoor cables UNITRONIC J-2Y(ST)Y...ST III BD Suitable for data transmission rates of up to 16 Mbits/s It is for example used for connecting EDP system units or for circuits for airfield lighting, ISDN private branch exchanges, operating data acquisition, operating data entry, access control and time recording systems, industrial electronics, all designed for maximum security and speed. Can be used in dry and wet interiors for fixed installation on and under plaster Polyethylene insulated installation cable 3and 4 pair model = cores layer stranded Flame-retardant acc. to IEC 60332-1-2 Core insulation polyethylene Foil wrapping, static screening of aluminiumlaminated plastic film with copper drain wire PVC blended outer sheath Colour: pebble grey (RAL 7032) In accordance with VDE 0815, see T 10 (800 Hz) max. 52 nf/km VDE regulation: VDE 0815/0816 > 5 GOhm x km K1: 98 % < 400 pf/300 m K9-12: 98 % < 100 pf/300 m attenuation / attenuation At 16 MHz < 8 db/100m In fixed installations: Short-range crosstalk attenuation 4-16 MHz: 2-pair >= 45 db 4-16 MHz: >2-pair >= 20 db core/screen: 2000 V fixed installation: -40 C to +70 C Characteristic impedance 100 Ohm +- 15 % Part number Number of pairs and conductor diameter, mm Outer diameter J-2Y(ST)Y...ST III BD 0034171 2 x 2 x 0.6 5.5 13.0 40.0 0034173 4 x 2 x 0.6 7.5 24.0 60.0 0034175 8 x 2 x 0.6 8.5 46.0 90.0 0034176 10 x 2 x 0.6 9.5 58.0 148.0 0034178 20 x 2 x 0.6 13.5 116.0 190.0 30017810 50 x 2 x 0.6 18.0 286.0 190.0 30017811 100 x 2 x 0.6 25.8 570.0 640.0 Comparable products UNITRONIC Li2YCY (TP) see page 261 Accessories STAR STRIP stripping tool see page 824 271

Halogen-free installation and fire alarm cables J-H(ST)H...BD Is used to meet enhanced fire protection requirements concerning people as well as high value property. J-H(ST)H...BD does not emit any toxic or corrosive gases in the event of fire and resists the spread of fire. This halogen free, flame retardant installation cable with static screen is used for telephone, data and signal transmission in subscriber stations and private branch exchange construction for telephone systems on dry and wet premises as well as on and under plaster. The resistance to combustion has been tested in accordance with IEC specification 60332-3 Halogen free and flame retardant installation cable in accordance with VDE 0815 Core insulation halogen-free Four cores twisted as star quad Foil wrapping, static screening of aluminiumlaminated plastic film with copper drain wire Colour: grey See table T10, according to VDE 0815 Max. 120 nf/km >100 MOhm x km K1: Approx. 300 pf/100 m K9-12: Approx. 100 pf/100 m In fixed installations: 6 x cable diameter fixed installation: -30 C to +70 C Part number Number of pairs and conductor diameter, mm Outer diameter J-H(ST)H-BD 3022220 2 x 2 x 0,6 8.0 14.1 65.0 3022221 4 x 2 x 0,6 10.0 25.4 100.0 3022222 6 x 2 x 0,6 11.0 37.0 117.0 3022223 10 x 2 x 0,6 12.0 59.0 155.0 30017787 2 x 2 x 0,8 9.0 25.0 77.0 30017788 4 x 2 x 0,8 11.0 45.0 135.0 272

Halogen-free installation and fire alarm cables J-H(ST)H...BD Fire Alarm Info The halogen free and flame retardant fire alarm cable in accordance with VDE 0815 Is used to meet enhanced fire protection requirements concerning protection of people as well as high value property Does not emit any toxic or corrosive gases in the event of fire and resists the spread of fire This halogen free, flame retardant installation cable with static screen is used for telephone, data and signal transmission in subscriber stations and private branch exchange construction for telephone systems on dry and wet premises as well as on and under plaster. The resistance to combustion has been tested in accordance with IEC specification 60332-3 Core insulation halogen-free Four cores twisted as star quad Foil wrapping, static screening of aluminiumlaminated plastic film with copper drain wire Outer sheath of special, halogen free polymer compound, colour outer sheath red. See table T10, according to VDE 0815 Max. 120 nf/km VDE regulation: VDE 0815 >100 MOhm x km K1: Approx. 300 pf/100 m K9-12: Approx. 100 pf/100 m In fixed installations: 6 x cable diameter fixed installation: -30 C to +70 C Part number Number of pairs and conductor diameter, mm Outer diameter J-H(ST)H...BD 30017798 2 x 2 x 0,8 9.0 25.0 77.0 30017801 10 x 2 x 0,8 15.0 106.0 250.0 273

Outdoor cables A-2YF(L)2Y...ST III BD Outdoor Outdoor armoured telephone cable available in the following types: A-2Y(L)2YB2Y (with additional PE outer sheath, black) A-2YF(L)2YBY (with additional PVC outer sheath, black) A-2YF(L)2YB2Y (with additional PE outer sheath, black) A-2YYBY (signal cable with armouring and PVC outer sheath, black) Do not place duct or directly buried underground cable in areas subject to fire hazard Other models such as for example, double armouring, other colours for the outer sheath (e.g. blue) on request Core insulation made from polyethylene (2Y) Every 5 star quads twisted into basic units, basic units and main unit twisted to form cable core Paper tape wrappin Laminated sheath of aluminium-coated plastic tape, black polyethylene (PE) outer sheath A-2YF(L)2Y...ST III BD Outdoor Like A-2Y(L)2Y, however with petrolat jelly filling, laminated sheath of aluminium coated plastic tape and black polyethylene outer sheath see appendix T10 At 800 Hz: max. 52 nf/km 225 V Impedance At 800 Hz 0.8mm: approx. 520 Ohm At 800 Hz 0.6mm: approx.720 Ohm VDE 0816 >5.0 GOhm x km A-2YF(L)2Y...ST III BD Outdoor >1.5 GOhm x km K1: 98 % < 400 pf/300 m K9-12: 98 % < 100 pf/300 m Conductor cross-section in 0.6 mm: 0.28 mm² 0.8 mm: 0.50 mm² attenuation / attenuation At 800 Hz 0.6 mm: Approx. 1.04 db/km At 800 Hz 0.8 mm: At 0.78 db/km A-2YF(L)2Y...ST III BD Outdoor At 800 Hz 0.8 mm: approx. 0.8 db/km At 800 Hz 0.6 mm: approx. 1.0 db/km C/C: 500 V core/screen: 2000 V 0.8 mm: 73.2 Ohm/km 0.6 mm: 130 Ohm/km For installation: -20 C to +50 C Installed: <= +70 C Use/application Do not place duct or directly buried underground cable in areas subject to fire hazard Part number Number of double cores Outer diameter A-2Y(L)2Y...STIII BD Cu-conductor 0.6 mm 1591050 2 10.5 11.0 80.0 1591051 4 11.0 23.0 125.0 1591052 6 11.5 34.0 130.0 1591053 10 13.0 57.0 165.0 1591054 20 16.0 113.0 265.0 1591055 30 18.0 170.0 355.0 1591056 40 19.5 226.0 440.0 1591057 50 21.0 283.0 525.0 1591058 70 23.5 396.0 705.0 1591059 100 27.0 565.0 950.0 1591061 200 36.5 1,755.0 1,755.0 1591063 300 42.5 1,696.0 2,525.0 A-2Y(L)2Y...ST III BD Cu-conductor 0.8 mm 1591150 2 12.5 20.0 100.0 1591151 4 12.0 40.0 160.0 1591152 6 13.5 60.0 175.0 1591153 10 15.0 101.0 235.0 1591163 14 16.5 141.0 296.0 1591154 20 18.0 201.0 390.0 1591155 30 21.0 302.0 540.0 1591156 40 23.5 402.0 680.0 1591157 50 25.0 503.0 835.0 1591159 100 32.5 1,005.0 1,515.0 274

Outdoor cables A-2YF(L)2Y...ST III BD Outdoor Part number Number of double cores Outer diameter A-2YF(L)2Y...ST III BD copper conductor 0,6 mm 1591028 2 8.3 11.0 67.0 1591029 4 10.4 23.0 104.0 1591030 6 12.0 34.0 140.0 1591031 10 14.0 57.0 190.0 1591032 20 17.5 113.0 310.0 1591033 30 20.0 170.0 430.0 1591035 50 24.5 283.0 660.0 1591037 100 31.5 565.0 1,225.0 A-2YF(L)2Y...ST III BD copper conductor 0,8 mm 1591217 2 8.8 20.0 83.0 1591218 4 11.2 40.0 134.0 1591221 6 13.5 60.0 195.0 1591222 10 15.5 101.0 275.0 1591223 20 19.5 201.0 475.0 1591224 30 22.5 302.0 665.0 1591225 40 25.5 402.0 860.0 1591226 50 27.5 503.0 1,050.0 1591228 100 36.5 1,005.0 1,985.0 Accessories SKINTOP MS-SC-M see page 568 Multipurpose shears A and B see page 818 STAR STRIP stripping tool see page 824 275