Vista-10SE System Design Sheet

Similar documents
Vista-20SEUL System Design Sheet

Vista-50P/-50PUL System Design Sheet

Vista-128FB System Design Sheet

VISTA-32FB. Commercial Fire/Burg/CCTV and Access Control Platform FEATURES: Designed to integrate seamlessly with CCTV, access

VISTA-128FBP/ V128FBP-24 Commercial Fire and Partitioned Burglary Alarm Control Panel

Wireless Products HONEYWELL SECURITY & CUSTOM ELECTRONICS. Honeywell s quick-install wireless devices, with their

VISTA 48DLCT HONEYWELL SECURITY

Fire Burglary Instruments Inc. XL-2G Gold Control/Communicator Installation Training Seminar Rev. 5/96

SECURITY ACCESS AND SURVEILLANCE SECTION VISTA-128FB ARCHITECT AND ENGINEER SPECIFICATION FOR SECURITY SYSTEM

SECURITY ACCESS AND SURVEILLANCE SECTION VISTA 250FBP ARCHITECT AND ENGINEER SPECIFICATION FOR SECURITY SYSTEM

DS7400Xi Addressable Control/ Communicator

Hardwired Alarm Accessories

HILLS RELIANCE 4 ALARM SYSTEM 4 zone panel

PRODUCT CATALOG. Concord Family Product Catalog. December 1999

INSTALLATION GUIDE XTLN-WIFI PANEL

Addressable Fire Alarm Control Panel

City of Menifee RFP for Intrusion Alarm Monitoring, Fire Monitoring/Testing and Maintenance Services at Various City Facilities Addendum #2 (5/2/2018)

VISTA-50P VISTA-50PUL

Intelligent technology made simple

ORENA BRAND CONVENTIONAL (ORENA Brand) CE

The CWSI System CALL WITH QUESTIONS. RELY ON OUR KNOWLEDGE. DEPEND ON OUR EXPERIENCE. (800)

VISTA-40. Installation and Setup Guide. 2-Partition Security System N7001V4 7/98

SHORT CIRCUIT ISOLATOR TO NEXT COMPONENT REQUIRING POWER TO NEXT KEYPAD (** IF REQUIRED) STROBE RELAY MODULE KEYSWITCH ISOLATION MODULE STROBE

VISTA-20SE INSTALLATION INSTRUCTIONS 2-PARTITIONED SECURITY SYSTEM.

Intelligent Analog/Addressable Fire Alarm/Voice Integration Systems. IntelliKnight TM Series

SECTION FIRE ALARM SYSTEMS

Security and Convenience Accessories

WIRELESS ALARM SYSTEM CR200 >SMART GPRS INTRUSION DETECTION PLUG & PLAY FUNCTIONS SELF-LEARNING, SMART FEATURES TEXT ZONE NAMING

DIVISION 28 ELECTRONIC SAFETY AND SECURITY

Wireless Sensors. Security unplugged. Interlogix wireless sensors deliver reliable detection and flexible installation for multiple applications.

Commercial Burglary Partitioned Security System With Scheduling. Installation and Setup Guide. N5944-6V2 5/04 Rev B

16.34 Multiplex Fire Alarm System Construction Standards Page 1 of 5

Control Panels. Control Panels for Commercial Applications. Control panels provide the central processing

Honeywell Combination Fire & Burglary Control Panel

SECTION INTRUSION DETECTION

SECURITY ACCESS AND SURVEILLANCE SECTION VISTA 250BP ARCHITECT AND ENGINEER SPECIFICATION FOR SECURITY SYSTEM

WIRELESS CONTROLS & DETECTORS

Smart detection. Interlogix commercial sensors feature the latest technology to deliver advanced detection and accurate, reliable performance.

VISTA-128B. Installation and Setup Guide. Commercial Burglary. Partitioned Security System. with Scheduling K3271 7/98

9,67$&1 6HFXULW\6\VWHP ,QVWDOODWLRQDQG6HWXS*XLGH K3892V1 4/00

Fire Safety Products Conventional Detection Audible/Visible Notification HVAC Systems Monitoring Sprinkler Systems Monitoring

Safety & Security. Smoke Detectors & Fire Alarm Systems. Intrusion Alarms Video Security Access Controls

>WIRELESS> ALARM SYSTEM CR200

Excel-EN Conventional Fire Control Panel

LifeAlarm Fire Alarm Controls

Unified Fire Authority - Fire Prevention Bureau

ERS-3600B. PERS-3600B Personal Emergency Reporting System

Model 17A00 Expansion Enclosure

VISTA-20HWSE INSTALLATION INSTRUCTIONS 2-PARTITIONED SECURITY SYSTEM

RDM LOCK G Series Electromagnetic Lock. Listings. Standard Features. Ordering Information:

9,67$36HULHV 6HFXULW\6\VWHPV ,QVWDOODWLRQDQG6HW8S*XLGH. The formatting of this version has been significantly revised. K5305-1V3 10/03 Rev.

ADEMCO VISTA SERIES VISTA-20P / VISTA-20PSIA VISTA-15P / VISTA-15PSIA Security Systems

Expansion Modules & Accessories

SP40S-D. Kingfisher Company, inc. Features: Description:

Wireless Devices. This chapter introduces the suite of DSC wireless sensors and devices used with the Impassa and other series of DSC alarm systems

MAXSYS Zone Control Panel PC4020. Maxsys Commercial Fire Panel PC4020CF. MAXSYS 16 Output Module PC4216

MODEL ZAC ZONE ANNUNCIATOR/CONTROLLER DESIGNED FOR ZONE ANNUNCIATION AND MONITORING

AMAX Intrusion Alarm Systems System overview

SP-1000X. Panic Device Power Controller Installation Guide. Rev

AND ARCHITECT SPECIFICATIONS

Control Panel. 1.0 GENERAL SCOPE OF WORK Introduction... 2

INSTALLATION GUIDE XR100 SERIES COMMAND PROCESSOR PANEL

icontrol OpenHome Converge Panel Interface Module Installation Guide Congratulations on purchasing your Panel Interface module.

Potter Wall Mount Select-A-Strobe

ADEMCO VISTA SERIES VISTA-20P / VISTA-20PSIA VISTA-15P / VISTA-15PSIA Security Systems

)$&3 ,QVWDOODWLRQDQG6HW8S*XLGH K5305-5V1 8/02 OFF FA260 3 STAY 2 AWAY 1 OFF 6 9 CHIME # 5 TEST 8 CODE B C # FA560 BYPASS MAX INSTANT READY ARMED READY

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information)

ADEMCO VISTA SERIES VISTA-21iP / VISTA-21iPSIA Security Systems

VISTA-10SE. Security System. Installation Instructions Installation Instructions Installation Instructions

Smart detection. Commercial Sensors

Easy Series ICP-EZM2. System Reference Guide

ALARM... CONTROL... PANELS... AND... KEYPADS...- WIRED...

DOOR MONITORING/DURESS SYSTEM

ADEMCO VISTA-10P ADEMCO VISTA-10PSIA Security Systems

INSTALLATION GUIDE XT30INT SERIES CONTROL PANEL

P Zone Expandable Hybrid Security System

Model 4880 Status Output Display Module Manual

ELECTRONIC SOUNDER STROBE Model : AVD-C407

Concerns: Affects: Dated: June 12, SECTION 1: GENERAL Scope Work Included... 3

9,67$39,67$3&1 6HFXULW\6\VWHPV ,QVWDOODWLRQDQG6HW8S*XLGH K /01 1 OFF 4 MAX OFF 7 INSTANT 9 CHIME READY

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev

HMS 1100 Installation Manual

2G & 3G GSM Portable PIR Alarm

CATALOG NUMBER. Features. Description

Testing the System. Battery Test. Dialer Test. Fire Drill Test (Code + [#] + 69) One-Man Fire Walk-Test (Code + [#] + 68)

Product Catalog 2nd Quarter 1997

Advent Home Navigator Product Line Overview Advent Home Navigator Named Best Network Subsystem

The following information shall become and form part of the contract documents.

good things in small packages

One panel offers everything you want built-in

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

SAFEPATH SAFEPATH. Emergency communications system

DIVISION 26 ELECTRICAL SECTION FIRE ALARM SYSTEM

D7024 Fire Alarm Control Panel

Control/Communicator 5110XM. Installation Instructions Installation Instructions Installation Instructions N8026 4/96

AlertWave. visiplex. From a Public Address System to an Emergency Communication System... The AlertWave system advantages:

NETWORK FIRE ALARM CONTROL PANEL. Features S7010 S :111

security timeless design innovative products inspired technology

2G & 3G GSM Door Contact Alarm

FA130CP. Installation and Set-Up Guide. K0735-1V1 4/04 Rev. A OFF FA260 3 STAY 2 AWAY 1 OFF 6 9 CHIME # 5 TEST 8 CODE B C # FA560 READY R BYPASS MAX

Transcription:

Vista-10SE System Design Sheet INTRUSION DETECTION HOLD UP CRITICAL EQUIP. SUPV. LONG RANGE RADIO SECTION 1: Basic Vista-10SE -Features QED programming for quick enrollment of devices Part No. Qty. Each Sub-Total (Eight Hardwired Zones, Wireless) Select one of the following: Vista-10SE Attack Pak (includes 6128, 747, 998 and 467) V10ATPK-KT Vista-10SE Kit 1 (includes 6139) V10BEST1-KT Vista-10SE Kit 2 (includes 6128) V10BEST2-KT Vista-10SE Kit 3 (includes 6128, 5881L, 5890, (4)5816 and (2)5808) V10BEST3-KT Vista-10SE Kit 4 (includes 6128, 5881L, (2)5816, 5890, 747,467 V10BEST4-KT Vista-10SE Control/Communicator (100mA)* VISTA-10SE Select the following for UL Commercial Burglary Installations Commercial enclosure for UL installations VISTA-ULKT If the system is to be monitored by a Central Station (CS) select the following: Phone block MO-RJ31X Select at least one, but no more than four, of the following: Fixed English Ash White Keypad (15mA)* (30mA)** 6128 Fixed English Ash White Keypad (40mA)* (85mA)** 6137 16 Character Ash White alpha keypad (40mA)* (100mA)** 6138 32 Character Ash White alpha keypad-customized English display (40mA)* (100mA)** 6139 Select at least one of the following: Yuasa 12 Volt DC, 7 AmpHr Battery NP7-12 Yuasa 12 Volt DC, 12 AmpHr Battery NP12A12V If required, select the following: Remote key switch for arming/disarming panel 4146 For interactive remote phone control select one of the following: Vista interactive phone module, supports arming/disarming, system status (160mA)* 4285 If required, select from the following for control functions: Addressable relay module (four form C relays) (one per system) (15mA)* (180mA)** 4204 Transformer/Interface for X-10*** 4300 Important Note: The Vista-10SE has six base hardwired zones, the remaining 16 zones/points can be configured with QED compatible wireless devices. The Vista-10SE provides up to 500mA which can be used to power remote consoles and other devices such as motion detectors or four-wire smoke detectors. If power requirements exceed control s capabilities, add power supplies as required, (see note under Power Supplies ). * Represents standby current draw ** Represents alarm current draw *** Must be used in place of regular system transformer when using X-10 devices. Vista-10SE Total Material Cost page 1 5/01/98 Total Hours page 1

SECTION 2: Wireless Accessories For use with QED control panels only. Part No. Qty. Each Sub-Total If wireless devices will be used select at least one and no more than two of the following: Wireless receiver (supports up to 16 wireless devices) (50mA) 5881H Wireless receiver (supports up to 16 wireless devices) (50mA) 5881M Wireless receiver (supports up to 8 wireless devices) (50mA) 5881L (above receiver required) Residential wireless smoke detector 5806 Residential wireless smoke detector 5807 Wireless smoke detector UL rated for commercial fire 5808 Wireless heat detector 5809 Wireless PIR detector 40 x 50 coverage 5890 Wireless glassbreak detector dual technology (audio/shock) 5849 Wireless micro-miniature transmitter 5814 Wireless two zone transmitter 5816 Wireless three zone transmitter 5817 Wireless recessed contact 5818 Wireless shock sensor 5819 Wireless low temperature sensor (45 degrees F) 5816Temp Wireless single button operation panic transmitter with belt clip 5802MN Wireless dual button operation panic transmitter with belt clip 5802MN2 Wireless four button transmitter key 5804 Wireless four button bi-directional transmitter key 5804BD Wireless two way portable keypad 5827BD Wireless transmitter module for use with 5827BD (connects to control) (20mA) 5800TM SECTION 3: Glassbreak Sensors (require remote power) Part No. Qty. Each Sub-Total Surface mount acoustic detector (30mA) 2520 Surface mount advanced acoustic detector (24mA) ASC25 Surface mount dual technology (shock/sound) detector (30mA) 2500 Surface mount shock sensor (1mA) ASC-SS1 SECTION 4: Door Contacts Part No. Qty. Each Sub-Total Industrial surface mount 4.125 x.62 SPST (BR-brown, GY-gray) 950BR Industrial surface mount 4.125 x.62 SPST wide gap (1.75 ) (BR-brown, GY-gray) 950W-BR Industrial surface mount 3.5 x.5 SPST (WH-white, BR-brown, GY-gray) with 6 cable 7945WH Industrial surface mount 3.5 x.5 SPDT (gray only) with 6 cable 7945-2GY Moisture resistant 3.5 x 1.2 SPST aluminum housing with 3 armored cable 960 Moisture resistant 3.5 x 1.2 SPDT aluminum housing with 3 armored cable 960-2 Overhead door contact SPST 959 Overhead door contact SPDT 959-2 Mini-surface mount with 5 zip cord, 1/2 gap 943 Mini-surface mount with 5 zip cord, 3/8 gap 951 SECTION 5: PIR Detectors (require remote power) Part No. Qty. Each Sub-Total Fresnel PIR with lookdown 50 x 50 coverage (17mA) 998 Fresnel PIR 50 x 70 coverage (17mA) 996 Fresnel Lens PIR 60 x 60 coverage (15mA) 1990 Quad AP Fresnel PIR 50 x 60 coverage (15mA) 1992 Recess mount PIR 40 x 56 coverage (15mA) 995 Ceiling mount PIR 8-12 ceilings (23 @ 8 )/(36 @12 ) (15mA) 997 Mirror PIR 35 x 45 coverage (15mA) 1875EX Quad AP gold mirror PIR 40 x 48 coverage (22mA) 1878GLD2 Twin element mirror PIR 40 x 48 coverage (22mA) 1876-2 Advanced quad AP detector 35 x 45 coverage (22mA) RX4 Advanced AP Gold detector 35 x 45 coverage (22mA) RX4GLD * Represents standby current draw Vista-10SE Total Material Cost page 2 5/01/98 Total Hours page 2

SECTION 6: Dual Tech Detectors (require remote power) Part No. Qty. Each Sub-Total Microwave/PIR 40 x 50 coverage (16mA) Quest 2000 Microwave/PIR 35 x 35 coverage (16mA) Quest 2135 Microwave/PIR 60 x 60 coverage (16mA) Quest 2160 SECTION 7: Photoelectric Beams (require remote power)*** Part No. Qty. Each Sub-Total Photoelectric beam two beams Max outdoor range: 80 (35mA) PBD25 Photoelectric beam two beams Max outdoor range: 160 (40mA) PBD50 Photoelectric beam two beams Max outdoor range: 250 (50mA) PBD75 Photoelectric beam two beams Max outdoor range: 320 (50mA) PBD100 Photoelectric beam four beams Max outdoor range: 160 (70mA) PBQ50 Photoelectric beam four beams Max outdoor range: 320 (90mA) PBQ100 Photoelectric beam four beams Max outdoor range: 500 (95mA) PBQ150 ***Important Note: For complete line of Photoelectric Beam detector accessories, refer to Commercial Security Products full line catalog. SECTION 8: Non-Addressable Hard Wired Fire Devices Part No. Qty. Each Sub-Total Manual pull station with key reset (screw terminals) 5140MPS-1 Manual pull station with Allen screw reset (wire leads) 5140MPS-2 Manual pull station with key reset (wire leads) MPS-5 Heat detector open contact, 135 degrees UL 502 Heat detector open contact, 190 degrees UL 504 Select four-wire smoke detectors as required: Smoke detector photoelectric, direct wire 2412/24R Smoke detector photoelectric, with heat sensor, direct wire 2412/24TR Select smoke detector accessories as required: Smoke detector sensitivity test module MOD400R Remote annunciator alarm LED for smoke detectors RA400Z Power supervision relay module for four-wire detection circuits (15mA)* A77-727-01 SECTION 9: Bells/Sirens/Strobes (require power) Part No. Qty. Each Sub-Total Motorized bell in box UL Grade A (100mA) AB12M Motorized bell in box UL (100mA) 1011BE12M Motorized bell UL (100mA) AD10-12M Strobe 12 Volt, 15 Candela, Red (114mA) SB1215 Strobe 12 Volt, 15/75 Candela, Red, ADA (142mA) SB121575 Horn 12/24 Volt, Red (12/23mA) HN1224 Horn/Strobe 12 Volt, 15 Candela, Red (124mA) HS1215 Horn/Strobe 12 Volt, 15/75 Candela, Red, ADA (152mA) HS121575 Horn/Strobe synchronization module (16mA) SM12 Horn/Strobe surface mount back box skirt SBS Horn/Strobe small mounting plate MP/S Indoor/Outdoor 25 Watt Eight Ohm siren with driver 4x4 box mount, 112db (550mA) 748LC Indoor wall mount siren, 85 db (320mA) 747UL Combination speaker and siren driver (30 Watts) 702 Indoor wall mount speaker 15 Watt Eight Ohm requires driver (15 Watts) 746 Select a driver for above speakers: 12 VDC selectable sound driver (15 Watts) 744 Selectable 3 languages (English, Spanish, French) 12 VDC voice siren driver (15 Watts) 745x3 * Represents standby current draw Total Material Cost page 3 Vista-10SE Total Hours page 3 5/01/98

SECTION 10: Power Supplies Part No. Qty. Each Sub-Total Select to provide additional current needs: 12-24 Volt power supply (supervised) (4 Amps) Al400UL-ADA 12-24 Volt (non supervised) (2.5 Amps) AD25624 6-12 Volt (non supervised) (1.2 Amps) AD12612 Select batteries for above power supplies Yuasa 12 Volt DC, 7 AmpHr battery NP7-1 Yuasa 12 Volt DC, 12 AmpHr battery NP12-12 Note: 1. For components not powered by the control, add current draw (ma) of devices. Select power supplies as needed to deliver required power. 2. Bells, sirens and strobes may require auxiliary power supplies. SECTION 11: Fire Alarm/Security Cables Part No. Qty. Each Sub-Total 18/4 Solid jacketed FPL fire rated wire, 500 Red, in box GJ-988040504 18/2 Solid jacketed FPL fire rated wire, 500 Red, in box WG-818424504 18/2 Solid zip FPL fire rated wire, 1,000 Red, in box GJ-978184604 18/2 Stranded, unjacketed, security rated wire, 1,000, White, in box WG-38162 18/4 Stranded, jacketed, security rated wire, 500, White, in box WG-28251 Wire Installation Labor Estimates Installation Difficulty Wire Run Distance Rate: (hours/feet) Wire Installation Hours Easy wire runs Feet Multiplied by 0.015 hrs/ft Medium wire runs Feet Multiplied by 0.025 hrs/ft Difficult wire runs Feet Multiplied by 0.100 hrs/ft Total Vista-10SE Total Material Cost page 4 5/01/98 Total Hours page 4

Total Job Cost Worksheet A. JOB RESPONSIBILITY JOB TYPE SYSTEM TYPE Total Job Installation Checkout Existing Building BA Card Access Equipment and Final Checkout New Construction FA Intercom Equipment Only Other CCTV Voice Evac. I.P. B. TOTAL MATERIAL COST: Add Material Cost Totals from previous pages. B. C. LABOR COST CALCULATION Add Total Labor Hours (material and wire run) from previous pages. Regular Hours X L.L. Rate = O.T. Hours X 1.5 L.L. Rate = O.T. Hours X 2.0 L.L. Rate = ------------------------------------------------------------------------------------------------------------------ Add Additional Hours if Required: Engineering Hours X Branch Rate = Project Mgr. Hours X Branch Rate = System Test Hours X Branch Rate = Training Hours X Branch Rate = TOTAL LABOR COST C. D. SUBCONTRACTOR LABOR Subcontractor Bid X % Overhead = D. E. MISCELLANEOUS COSTS Additional Insured / Spot Insurance Blueprints, Manuals, Etc. License, Permits, Etc. Shipping Costs Warranty Costs Inspection Costs Equipment Rental Costs Mileage and Per Diem Costs Hardware Other TOTAL MISCELLANEOUS COSTS E. = TOTAL JOB COST (Total B, C, D + E) X PROFIT MARGIN % = DIRECT SALE PRICE Vista-10SE 5/01/98