Business Name. Primary Business Addr ess

Similar documents
Fisher Hanmer INSTALLATION & OPERATION INSTRUCTIONS FREESTANDING WOOD FIRE. January

SOLID FUEL HEATER JAYLINE CLASSIC CA FS 2006 INSTALLATION & OPERATION INSTRUCTIONS FEBRUARY 2007

INSTALLATION & OPERATION INSTRUCTIONS

Installation & Operation Manual

JAYLINE CA FREESTANDING WOOD FIRE

FR300W JAYLINE CLEAN AIR FREESTANDING WOOD FIRE OWNERS MANUAL & INSTALL INSTRUCTIONS. Please leave this information with the appliance

Dovre 700CBW Cast Iron Wood Stove INSTALLATION INSTRUCTIONS 700G/1095

Installation and Operating Instructions for the following Woodsman models

Installation & Operation Manual Fascia / Firebox / Build-In Cabinet

TECHNICAL MANUAL. Multifuel Stove Model EW1MF. To be retained by the user for future reference. Serial Number. Document EW1MF 0209

Varde Shape. Smoke Control Kit. Additional Installation and User Instructions for use in Smoke Control Areas

Varde Aura. Smoke Control Kit. Additional Installation and User Instructions for use in Smoke Control Areas

Specialists in fireplace design and manufacture CUBE DOUBLE SIDED INSTALLATION & OPERATING INSTRUCTIONS IMPORTANT:

Bergen PRPMXXXX. Smoke Control Kit Additional Installation and User Instructions for use in Smoke Control Areas

WOOD FIRE OWNERS MANUAL

CE EN13240 ENJOY YOUR STOVE SAFELY. Multifuel Cast Iron Stove INSTRUCTION MANUAL

Troubleshooting and Maintenance: Wood Stoves

Nectre N60. Operating Instructions. Efficient Warm Friendly. Keep instructions in a safe place for future reference.

Quadro 1, 2 & S-31A Insert

Part 1: Installation Instructions for WAGENER SPARKY (Please keep these Instructions for future Reference)

HOMEOWNER'S GUIDE FOR YOUR CONTEMPO FIREPLACE TABLE OF CONTENTS

Nectre MK2 LE. Operating Instructions. Efficient Warm Friendly. Keep instructions in a safe place for future reference.

Nectre Inbuilt LE. Operating Instructions. Efficient Warm Friendly. Keep instructions in a safe place for future reference.

Part 1: Installation Instructions for WAGENER LEON- Multi Fuel

qüé=`üáãåéó An effective chimney is an important part of any successful wood-burning system.

Getting to know your Metro... 6 Assembling your Metro Operating your Metro... 6 Floor protector requirements... 4

OWNERS MANUAL. Operational and Maintenance Instructions Please retain this manual for future reference

COUPE INSERT INSTALLATION & OPERATING INSTRUCTIONS

CROMWELL Installation & Operations Manual

DÉCOFIRE. Contemporary CHIMENEA. Assembly, Safety & Operating Instructions FOR OUTDOOR USE ONLY READ INSTRUCTIONS CAREFULLY BEFORE ASSEMBLY OR USE.

Troubleshooting Guide

THERMALUX SOLID FUEL SLOW COMBUSTION COOKERS AND BOILERS

HOMEOWNERS GUIDE FOR YOUR WOOD BURNING FIREPLACE

HOMEOWNERS GUIDE FOR YOUR WOOD BURNING FIREPLACE

Specifications, Installation and Operating Instructions for Woodsman Solid Fuel Burners

Studio. Freestanding Cassette Range. Instructions for Use. For use in AU & NZ (Australia and New Zealand)

CELESTIAL 900 FREESTANDING

INSTALLATION & OPERATING INSTRUCTIONS

SUPER NOVA FREESTANDING SERIES III INSTALLATION & OPERATING INSTRUCTIONS

A message from the Holyrood Fire Department. Chimney Fire Safety

MYSTIQUE Installation & Operations Manual

INSTRUCTIONS MANUAL FOR USE AND MAINTENANCE

OPERATION, MAINTENANCE & WARRANTY INFORMATION FOR YUNCA WOOD BURNERS.

MG SERIES - ENERGY CLASS A. Meeting the. MG series 1 / 7

THE INSTALLATION AND OPERATING INSTRUCTIONS IN THIS MANUAL APPLY TO MASPORT TALISMAN WOODFIRES

TECHNICAL MANUAL. Multifuel Stove Model MV1MF. To be retained by the user for future reference

INSTALLATION & OPERATING INSTRUCTIONS

Newton Multi Fuel 5kW Space Heating Stove

CHARNWOOD COUNTRY 6 FT

INSTALLATION & OPERATING INSTRUCTIONS

TABLE OF CONTENTS. Site preparation 2 Placement. 2 Chimney and stove pipe connections. 2

INSTALLATION AND OPERATION MANUAL

TECHNICAL MANUAL. The Buxton. Multifuel Stove Model BX1MF. To be retained by the user for future reference

SUPERIOR CAST IRON FIREBOXES MADE IN NEW ZEALAND WOOD FIRES

OWNER S MANUAL. DS Greenhouse Blast GH450. Do Not Discard This Manual. High Efficiency Wood or Coal Green House Furnace. Model:

tççç= ÜÉ~íáåÖ çéíáçåë

Wood Fire Installation Manual. ECO Freestanding Models. Radiant Fires ECO Tiny Rad ECO Wee Rad ECO Wee Curve ECO Xtreme Rad ECO Euro Rad

Newton Multi Fuel 8kW Space Heating Stove With Boiler

Technical Specifications Panoramic FX1

600 SERIES INSTALLATION & OPERATING INSTRUCTIONS

KEMLAN CELESTIAL 900 INSTALLATION & OPERATING INSTRUCTIONS

Thank you for purchasing a new Euro Fireplaces unit

CHARNWOOD COUNTRY 8B WOODBURNER OPERATING INSTRUCTIONS

Manor maxiheat. Owners Manual For. Wood Heater

OPERATING & INSTALLATION INSTRUCTIONS FOR ZERO CLEARANCE WOOD INBUILT

User s Manual WS-4830SS WS-4836SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.

Thank you for purchasing a new Euro Fireplaces unit

DROLET WOODSTOVE MANUAL

MODEL SORDO SORDO SORDO SORDO 80 Flatline

Website:

WOOD STOVE SERVICE MANUAL

HELIX OWNERS MANUAL. Scandia Heating (Aust) Pty Ltd

1. Contents Principle General information Parts list Assembly Technical drawing... 18

Freestanding Wood Fires

Dovre 250 Cast Iron Gas Stove

OSBURN 2000 (OB02005 Model)

Studio Stove 0.95 Grams Per Kilo

Mendip 5 standard and pedestal stove Multi-Fuel, Wood, Smoke control model 4.8 kw / 5.2kW Space Heating Stove

Please read this booklet, for the safe installation of your MULTI FUEL FIRE

User s Manual WS-69TB30 / WS-69TB36 (22 ) WS-69TB42 / WS-69TB48 (22 ) WS-69TS30 / WS-69TS36 (18 ) WS-69TS42 / WS-69TS48 (18 )

TALISMAN OWNER S MANUAL AND INSTALLATION GUIDE

SAEY 92 (TOP) WOOD/COAL

Malvern II. Multifuel Stove Model MAL2MF. To be retained by the user for future reference Thank you for purchasing an ACR Heat Products stove

Cast Iron Fireplace Insert

RENAISSANCE LINEAR 50 Keep these instructions for future use.

Scandia Avante Open Fire

ULTIMATE INSET LIVE FUEL EFFECT GAS FIRE MODEL 417 OWNER GUIDE

Novus. Multifuel Stove Model Novus. To be retained by the user for future reference. Thank you for purchasing an ACR Heat Products stove

LTD Freestanding Models

WARMBRITE RANGE OWNERS MANUAL SERIES 2 SERIES 3. Scandia Heating (Aust) Pty Ltd

ESSE 990 Cooker OPERATING INSTRUCTIONS MODEL: 990 Wood/Smokeless Solid Fuel Models N (no boiler) and D (domestic hot water boiler)

Oxford 5. Operation and Installation Manual. Version A 21/06/2017 (MZSOX5SMB) IMPORTANT

MUCH WENLOCK CLASSIC NON-BOILER SOLID FUEL STOVE

Exmoor/Exe/Devon. Freestanding Stove. Instructions for fitting Smoke Control Kit. For use in GB & IE (Great Britain & Republic of Ireland).

H530. Installation and user manual. - Please read this manual carefully and save the instructions - Version: 10/09. Tested and Listed by:

User s Manual ISLAND SERIES TABLE OF CONTENTS RA-7630SS RA-7636SS RA-7642SS RA-7648SS. Table of Contents. Safety Information...

Caliente. Tested and approved to Australian Standards AS/NZS 2918:2001 and AS/NZS 4013/4012:2014.

HUNTER HAWK 4 MKII GAS STOVE

Rocket heater GAMERA

Classic Pricotech proudly supports the activities of Landcare Australia through its membership of the AHHA.

Transcription:

Business Name Primary Business Addr ess Your Add ress Line 2 Your Add ress Line 3 Your Add ress Line 4 Phone: 555-55 5-5 555 Fax: 555-55 5-5 555 E-mail: s ome one@ exa mple.c om

LIGHTING YOUR FIRE QUICK GUIDE TO GETTING STARTED 1. Place some dry kindling on top of crumpled newspaper on the base of the firebox. 2. Ensure the airslide control is on high then light the paper. 3. Once the kindling is well alight add a few heavier pieces of wood and close the door. 4. Gradually build up the fire by adding 2 or 3 small logs at a time whilst ensuring the air control is still in the high position for at least 30 minutes. 5. Once the fire is well established, regulate the heat output to the desired level by adjusting the airslide control. 6. When refuelling your fire make sure the air control is fully opened prior to opening the door. This will reduce the possibility of smoke spillage into the room. Open the door slowly and reload the fire. Leave the airslide control on high for a few minutes before adjusting the air control to suit the heat level required. 1

IMPORTANT MESSAGE TO THE OWNER PLEASE ENSURE YOU FULLY READ PAGES 1 AND 2 AND UNDERSTAND THE INFORMATION, EVEN IF YOU DON T READ THE ENTIRE MANUAL!! We at Glen Dimplex Australasia thank you for choosing a Logaire fire and are confident if installed and operated correctly will bring you many years of pleasure. Our fires are designed to give you many years of warmth and service, subject to the following three critical factors. 1. A competent and suitably qualified installer must install your Logaire fire correctly. Your Logaire dealer will be able to arrange professional installation for you. 2. You must burn properly seasoned dry wood. 3. You must know how to correctly operate your Logaire fire, particularly on overnight burn cycles. PLEASE NOTE THE FOLLOWING IMPORTANT POINTS: When lighting the fire for the first time, ensure that the stove, glass, trim and flue are all dusted to avoid particles sticking or discoloring the fire. Once fired, some smoke and vapor will be released as the VHT painted surfaces enter the final curing process. Do not be alarmed, open all windows and doors in that room and close any internally opening doors. This curing process will last for up to 3 hours as you run your fire on high and will only happen this one time. People with respiratory, heart or other relevant medical conditions should avoid inhaling vapors during the curing process. In Christchurch and Canterbury the Hestia Clean Air, Atlanta Clean Air and Pyros Clean Air Models cannot be installed with the No Match system. 2

Properly seasoned (dry) timber is necessary for the Logaire to operate efficiently. Firewood that contains a high moisture content will result in flue blockages, blackened glass and reduce the heat output of the Logaire substantially. Please note: - Softwood usually takes 6 12 months to season - Hardwood can take up to 24 months to season - Wood must be stored in a location that enables free air circulation. Wet wood stored in a closed woodshed without air circulation will still be wet 12 months later. REMEMBER - when two pieces of seasoned wood are hit together you should hear a high-pitched ring, not a low-pitched thud. DO NOT BURN COASTAL DRIFTWOOD OR TREATED TIMBERS. For optimum performance fuel should be loaded so the log lay front to rear in preference to lying across the width of the firebox. Spaces should be left between the logs to enable oxygen to get to as much of the surface of the fuel as possible. Your Logaire is covered by a full twelve-month warranty on parts, and a ten-year warranty on the firebox. REMEMBER - In New Zealand local by law requires that your fire have a permit whether it is a new purchase or an upgrade. Your Logaire dealer can explain all this and supply relevant paperwork. HERE ARE SOME THINGS YOU SHOULD NEVER DO WITH YOUR LOGAIRE: 1. Never burn treated or unseasoned (wet) wood. 2. Never empty ash into a plastic bucket or paper bag as ash can stay hot for days. 3. Never dry clothes on your Logaire. 4. Never operate your Logaire with the door ajar except on initial start up. 5. Never use petrol or other volatile liquid fuels. 3

LIGHTING AND OPERATING YOUR MULTIFUEL 1. Place some dry kindling on top of crumpled newspaper on the base of the firebox. 2. Ensure both the airslide controls are on high, then light the paper. 3. Once the kindling is well alight add a few heavier pieces of wood or coal and close the door. 4. Once the fire is going well, shut the top air slide control to halfway and control the heat out put with the bottom air slide control. 5. When refuelling your fire ensure that the airslide control is on high prior to opening the door. This will reduce the possibility of smoke spillage into the room. Open the door slowly and reload the fire. Leave the airslide control on high for a few minutes before adjusting the airslide control to suit the heat level required. 6. You will need to clean the ash pan out on a regular basis when using coal. 4

WHERE TO POSITION YOUR LOGAIRE FIRE IN YOUR HOME It is important to position the wood stove in an area that will favor the most efficient heat distribution possible throughout the house. The stove should therefore be installed in the room where the most time is spent, and in the most spacious room possible. The correctly sized unit for the home is also important. Too large a stove and it will be constantly run on low, causing poor combustion and creosote problems restricting the flue updraft. Too small and it will fail to generate sufficient heat to warm the area. Logaire recommend a site check of the home by a certified fire installer before installation. Bear in mind that while the heater may generate sufficient heat, it then has to be circulated throughout the home. If the house doesn t allow natural dispersal of heat (e.g., high ceilings, long hallways, etc) circulation can be improved with a ceiling fan or (Logaire) heat transfer kit. Important: A wood stove must never be installed in a hallway or near a staircase, as it may block the way in case of a house fire or fail to respect the required clearances. OPTIONAL WATERBOOSTERS Water boosters can offer substantial power savings, dependent on the area and climate in which you live. If you live in a cold climate you are likely to use your Logaire for many months of the year, in which case a Logaire water booster will reduce your water heating costs over these months. The optional water booster for your Logaire fire must be positioned within the firebox chamber of the heater. To ensure efficient water booster operation, the heater should be installed as close as possible (less than 3 metres) to the hot water cylinder. The diameter of the pipe work running to and from the water booster should be at least 25mm. Sharp bends and other restrictions must be avoided. The internal return flow pipe from the water booster to the cylinder should pass through the bottom of the cylinder to terminate at least two thirds the height of the cylinder. The outlet pipe from the cylinder to the water booster should begin 100mm above the bottom of the cylinder to avoid contamination by the sediment within the cylinder. A gradient of 1 in 12 inches should be maintained on all pipe work running between the water booster and the hot water cylinder. All exposed water pipes should be lagged to prevent heat loss and to ensure safety when the pipes pass through combustible walls, etc. If a mains pressure hot water system is in use the installation of a water booster is more difficult and expert advice should be sought. 5

OPERATING YOUR LOGAIRE FIRE OPENING THE DOOR 1. Ensure that the airslide control knob is fully adjusted to high. 2. Turn the door handle in an anticlockwise direction and slowly pull door open. On the Hestia and Atlanta Bay, firmly hold the door handle and lift upwards approximately 90 degrees whilst pulling the door open. ADJUSTING THE AIRSLIDE CONTROL 1. The air slide control is positioned on the top left hand side of the fire. 2. This control moves from left to right, left being low and right being high. This gives you total control of the burn rate at all times. 3. On the Pegasus and Hestia Multifuel a second air slide control is positioned above the ash pan on the left. When using a mixture of wood and coal or coal only, close the top air slide control halfway and ad just the burn rate using the bottom air slide control. STARTING AND MAINTAINING A FIRE To start and maintain a good fire you need the following items: 1. A small quantity of newspaper (do not use coloured or coated paper) 2. A packet of firelighters (optional) 3. A quantity of finely split dry soft wood kindling in a variety of sizes. 4. Seasoned firewood split into a range of piece sizes The first step is to crumple half a dozen sheets of newspaper and put them just inside the firebox. The amount of newspaper you need will depend on the firebox size and the dryness and fineness of the kindling you are using. The drier and finer the kindling the less newspaper you need. Be generous with the newspaper and you will have more success. Placing some firelighter halves under the newspaper will also help to sustain the firebox temperature until the wood is burning. On top of the paper place 10 to 15 pieces of finely split dry kindling. Softwoods such as cedar or pine make good kindling. Ideally the kindling should be placed on and behind the newspaper so that the combustion air reaches the newspaper fast where you ignite it. It is also a good idea to add two or three very small pieces of firewood to the kindling load before lighting. Set the airslide control to high, light the firelighters or the newspaper and close but do not latch the door. After about 5 10 minutes when the wood is flaming brightly, latch the door. As leaving the door open slightly can cause dangerously high temperatures, NEVER leave the woodstove unattended while starting the fire. 6

OPERATING YOUR LOGAIRE FIRE Note for Clean Air models (eg Hestia Clean Air) Seasoned firewood has to be placed within the firebox as shown in the picture below. The wood must be placed in a back to front and diagonal configuration. This will give you the overall emission and room heating efficiency that the fire was designed and tested to achieve, plus meet local council requirements. Do not load firewood across the firebox from side to side. This will impede the performance of the fire. 7

When the flames from the kindling load just begin to subside add several small pieces of firewood. Try to avoid smothering the fire with the new pieces. Placing the pieces on and behind the burning kindling can help prevent smothering. As your Logaire woodstove is a convection fire it requires approximately 45-60 minutes to preheat the steel firebox before it can effectively convect heat into the room. A well maintained hot fire will reduce the preheat cycle. FIRE IN CYCLES Don t expect perfectly steady heat output from your Logaire woodstove. Woodstoves burn best in cycles. A cycle is the time between the ignition of a load from charcoal and the consumption of the load back to a hot ember bed. Each cycle should provide between four and eight hours of heating depending on how much wood was used and how much heat is needed. Plan the firing cycles around your household routine. If someone is home to operate the fire build a small hot fire. If you must be away from the house during the day build a long burning fire. THE SMALL HOT FIRE A small hot fire is when a small amount of wood is burnt quickly. This is best used when you just want to take the chill off the house usually in spring and autumn. To build a small hot fire: 1. Rake the embers towards the front of the fire and place several small pieces of wood onto it. The bottom layer should be positioned to ensure that combustion air can flow over the embers and along the length of the pieces of wood. 2. The next layer should be stacked loosely in a crisscross arrangement. 3 Open the airslide control to high to produce a hot bright fire. 4 After approximately 15 to 20 minutes the air supply can be reduced slightly as the fire progresses, but never enough to extinguish the flames. 5 When only charcoal remains the air supply can be reduced further to prevent cooling the ember bed. EXTENDED OR OVERNIGHT BURNING The Logaire fire range will burn overnight provided the customer is correctly loading and burning dry hardwood, e.g., Manuka, Blue Gum, Black Wattle, with a moisture content of less that 25%. For best results load a well established ember bed with larger dry hardwood logs and run on high for at least 45 min before turning the airslide control down in three 15 minute stages (med, low and off). The most important rule is NEVER LET THE FIRE SMOULDER. As long as there is solid wood in the firebox there must be flames present or the unburned gases will escape both reducing efficiency and increasing air pollution. 8

MAINTENANCE OF YOUR LOGAIRE FIRE To keep your woodstove burning clean and efficient it is important that you carry out regular maintenance: 1. It is wise to perform a visual inspection of the fire approximately once a month, in order to ensure that no parts have been damaged, in which case repairs must be performed without delay. 2. In the unlikely event of the door glass breaking, a replacement can be purchased from your Logaire dealer. NOTE: Do not operate your heater with broken glass and under no circumstances should a nonceramic type glass be used. 3. Never wash the glass or fire with a product that may scratch it. Logaire fires have a vitreous enamel surface, which just needs wiping clean. 4. Ash removal due to the high efficiency of your Logaire woodstove ash removal should only be necessary every few weeks. Ashes can be removed easily through the fire door when the fire is at its lowest, such as first thing in the morning or when it is completely out. Logaire wood fires work best when a small amount of ash (approximately 20mm deep) is left in the firebox after cleaning. This insulates the bottom and prevents the base of the stove overheating and burning out. In fact, building up the ash bed helps extend the long burn cycle while reducing the ash bed encourages greater heat output. 5. Firebox check the firebricks, top baffle and interior surfaces. These parts are subjected to considerably high temperatures and stress and some parts will eventually need replacing. 6. Doors Check all gaskets used for wear and replace if necessary. Adjust door fitting if required. 7. Lubricating All moving parts should be lubricated with graphite grease every couple of months. CHIMNEY CLEANING AND MAINTENANCE OF FLUES For all wood heaters, flue cleaning must be done regularly to avoid serious flue fires. Frequently used heaters should be cleaned at least once a year (some sooner). The cleaning rate however depends on the burning habits of the individual operating the wood heater. For example, it is possible to clog a flue in just a few weeks if smouldering fires are burnt and the flue is run cold. It is recommended that flue sweeping be done by a professional chimney sweep. Chimney sweeping is a specialist task and competent professional sweeps are available throughout the country. Flues should be checked at least once or twice a heating season. Flues may require checking more often if the fuel or operation of the appliance is incorrect. When a flue becomes excessively blocked or requires frequent cleaning, advice should be sought to investigate the installation and the operation of the heater. Flues can deteriorate very quickly with incorrect firing. 9

LOGAIRE WARRANTY Glen Dimplex Australasia Ltd warrants all of the below components, excluding glass, if proved to be defective in material or workmanship under normal domestic use for a period of one year: Door Glass and Seal Firebricks and brick retainers Secondary Air Tube Removable baffle Water boosters Flue Systems Glen Dimplex Australasia Ltd warrants the steel firebox against defective materials and workmanship that would render it unfit for normal domestic use within a period of ten years after date of original purchase. WARRANTY CONDITIONS The wood fire must be installed, operated and maintained in accordance with the building code and the manufacturers installation and operation manual. This warranty covers the replacement or repair at the manufacturers discretion but excludes freight or travel costs The manufacturer or their agent are not liable for any loss or expense direct or indirect arising from the failure of any part of operation of the heater. This warranty does not cover damage caused by: - Work done by others i.e. chimney sweeps, plumbers and installers The burning of improper fuel, chemically treated wood, bituminous coal, coastal driftwood and unseasoned wood. Flue kits and accessories. Water boosters. CLAIMS Any claim under this warranty should be submitted first to the dealer from whom the unit was purchased. If for any reason the Dealer cannot be located or you feel it necessary to speak to us direct, please do so on (09) 274 8265 or forward your claim in writing stating the model and serial number, date of installation and outlet purchased from, to Glen Dimplex Australasia Ltd. In order for the warranty to be valid, the Warranty Card must be completed in its entirety and mailed within 30 days of the date of installation to: GLEN DIMPLEX AUSTRALASIA LTD P O BOX 58 473, GREENMOUNT,, MANUKAU 2141 AUCKLAND, NEW ZEALAND. 10

PROBLEM SOLVING PROBLEM REASON FOR PROBLEM SOLUTION Dark, dirty film Burning wet or green firewood or Ensure only dry seasoned wood is used. On door glass extended burn time on low setting or Burn heater on high to burn off worst of dirty film. leaking door seal. Adjust door tightness and check door and glass seals. Your Logaire Dealer can help with this. TO REMOVE DIRTY FILM BURN ON HIGH FOR 30 MINUTES DO NOT TRY AND SCRUB OR WASH OFF. Creosote Creosote is a tar-like substance that builds The most effective way to control the creosote formation Build-up up when the organic compounds in smoke is to burn the woodstove on high regularly and never allow condense onto cooler surfaces. Creosote a fire to smoulder. can build up over time and restrict the airflow of the flue and impair the performance of the woodstove. Occasional puffs There could be insufficient flue height in This is usually a problem when the wind is coming from of Smoke relation to your roofline, trees or other high one particular direction and requires an experienced installer Entering the obstacles near your home, which could be to remedy, by either extending your flue height or fitting room causing a down draft. a directional H cowl. If the wood fire is refuelled and left on a low setting allowing it to smoulder, the firebox Ensure your fuel is seasoned and the airslide control is will fill with smoke and combustible gasses. Set on high when refuelling the wood fire. The fuel will eventually ignite and when it does so, the build up of gasses will cause a pressurisation forcing smoke into the room. 12

PROBLEM REASON FOR PROBLEM SOLUTION Smell of smoke in The smell is creosote that will be seeping Refer to the overnight burn section on pages ** The room the through the flue joints or out of the flue for correct burning methods. Make sure wood is Morning spigot onto an external surface, thus creating properly seasoned. After an the smell in the room. This will be due Overnight burn o either unseasoned fuel or incorrect operation on overnight burn cycles. Extreme negative This is when the air circulates down from the To prevent this extreme negative pressure Pressure in the house chimney towards the interior of the house. open a window approximately 6mm to Negative pressure is often what causes smoking allow combustion air into the room. problems. Energy efficiency practices and new building code rules are making our houses more and more airtight. This makes the house s energy efficient but also makes them more sensitive to negative pressure when air is exhausted from the house. Large fan forced exhaust ventilators, like downdraft type kitchen stove exhausts can cause extreme negative pressure in the house when they are operating. Because new houses are tightly sealed there are few holes to allow replacement air to enter and the house pressure becomes negative. This negative pressure works against flue system draft. In severe cases the negative pressure in the house overcomes the flue system draft and the appliance begins to spill smoke, especially when a fire is started or when it dies down to coals. 13

WARRANTY CARD PLEASE COMPLETE AND RETURN TO:- NAME: ADDRESS: GLEN DIMPLEX AUSTRALASIA LTD, P O BOX 58 473, GREENMOUNT, MANUAKU 2141 AUCKLAND, NEW ZEALAND PHONE NUMBER: MODEL: DATE PURCHASED: SERIAL NUMBER: DEALER PURCHASED FROM: INSTALLED BY: DATE INSTALLED: TO BE FILLED IN AND RETURNED WITHIN THIRTY DAYS OF INSTALLATION TO THE ABOVE ADDRESS. Glen Dimplex Australasia Ltd reserves the right to change specifications or design of its product without prior notice. 14