Ion PGM Hi Q View Sequencing Kit

Similar documents
Ion OneTouch Template Kit Publication Part Number Revision E Date 31 October 2011

MiniAmp Thermal Cycler and MiniAmp Plus Thermal Cycler Installation and Operation

Thermo Scientific KingFisher Total RNA Kit Instruction Manual Rev. 1.2

STANDARDD OPERATING PROCEDURE FOR THE LUMINEX

Thermo Scientific KingFisher Viral NA Kit Instruction Manual Rev. 1.2

Thermo Scientific KingFisher Pure RNA Tissue Kit Revision 1.0

Thermo Scientific KingFisher Pure RNA Plant Kit Revision 1.0

RNAscope LS 4-plex Fluorescent Assay

wash system V1.3 Important: Up to slides on one injection. Note: Getting need to turn it samples the next day. and put the slides in foil, put it

TECHNIQUES IN MOLECULAR BIOLOGY BASIC TECHNIQUES: PIPETING AND STERILE CULTURE

Sanitise Syrup Lines & Valves. Taylor PH61 Cleaning every 14 days

Introducing New 96-Well Fast Plate Adapters for Applied Biosystems Capillary Electrophoresis Systems

PrimePour TM Operation Manual

Radioactive In Situ Hybridization Protocol (HBMI Core University of Rochester Medical Center)

Thermo Scientific KingFisher Pure RNA Blood Kit Revision 1.0

Operating Instructions

Rain Forest Quick Guide

User Manual. Please read this User Manual and the Safety Information before operating the Soda Maker.

QIAcube HT Unpacking and Installation Instructions

Thermo Scientific Wellwash Versa User Manual. Rev. 1.0

Thermo Scientific Wellwash User Manual. Rev. 1.0

OPERATOR'S MANUAL HD-400

until filters are dry. Once dry, place the filters shiny side up in petrislides. The petrislide do NOT need to be acid washed.

OPERATOR'S MANUAL HD-400

Cleaning the internal optics surfaces

Operator s Manual. The Bullet Blender 50 BB50-AU, BB50-DX. Contents. Congratulations!

OPERATOR'S MANUAL CD 400 / CD 500

OWNER S MANUAL AND INSTALLATION GUIDE PLEASE READ THIS MANUAL CAREFULLY BEFORE ATTEMPTING INSTALLATION

Mitocell: Instructions for Use

QUICK START GUIDE SPIRIT ONE TOUCH. Please read this Quick Start Guide before using the Sparkling Water Maker.

AC6 & AC8 HORIZONTAL SERIES Sealed Metallic Centrifugal Pumps Installation and Maintenance Instructions

Product Guide for Ludger Clean Post-endoglycosidase and Post-exoglycosidase Clean-up Plate

Hg5 Amalgam Separator Installation and Operations Manual

Rules for Safe Operation

PRO 2000i LOW LEVEL DEPOSITOR

FROZEN CONCOCTION MAKER

THE WATER VITALIZER PLUS ADVANCED OXYGENATION SYSTEM

A few simple steps to ensure perfect water, every time.

ELISA NIMBUS. Automated ELISA Processing System

Operating Manual for. Ultrawash Plus. Absorbance. Plate Washing. Luminescence. Automated Processing. Software

AMPHASYS AG TECHNOPARK Lucerne Platz 4 CH-6039 Root D4 Switzerland phone

OPERATOR'S MANUAL HD-500/550

Humidifier. Owner s Guide. English. Model Form# Hunter Fan Co Hunter Fan Company

Pos-D Positive-Displacement Pipette for Problem Liquids

SimpleVIS Viscometer Reference Guide P

Setup Guide. Thank you very much for purchasing this product.

DOC JAN06 LT 200

High Speed Personal Blender

ACME DIAGNOSTICS STANDARD OPERATING PROCEDURE

USER MANUAL CDL MAPLE CREAM MACHINE. CDL Maple Sugaring Equipment Inc.

User Guide. Double Junction Reference Electrode

Guide to the Art Robbins Gryphon (and Phoenix) Crystallization Robot at UAB (CBSE)

CONGRATULATIONS! TABLE OF CONTENTS

Services Unlimited Inc./Parts Guru. Assembly

CPAP Washbasin Manual

DISPENSE TROUBLESHOOTING INDEX. Hot Tank Descaling Instructions are included in this Troubleshooting section.

UNITY 2 TM. Air Server Series 2 Installation Manual. Version September 2012

Thermo Scientific KingFisher Flex User Manual

BMW E36 Thermostat Removal And Coolant Flush

CER-1 & CER-2 Installation & Testing Instructions

3 Scotch Mini-Weld Adhesive System User s Manual

REVIVAL LITE VITREOUS CHINA REVERSE TRAP TOILET

One-Touch Dispense. Multi-temp selections. 208 F For tea, coffee, instant noodle. 194 F Keep warm around 194 F. 176 F Keep warm around 176 F.

Laboratory Glassware Cleaning and Storage

WARNING. Pro Pack Portable Spray Pack 3A1292C. Operation. Model 24F893 Maximum Working Pressure 12 psi (0.83 bar, MPa)

COMPRESSED AIR DRYER. SAFETY... Page 2 MAINTENANCE... Page 5. INSTALLATION... Page 3 PARTS AND KITS... Page 6

ACQUITY UPLC HT Column Heater Instructions

BAXTER: FACTOR VII 600 IU (Plasma Derived)

2001 Smith Eastern Corporation

PumpLab TM Operator s Manual

SuperKlean Washdown Products

Installation Instructions. Remanufactured Veeder-Root Sump Sensor. PMP # 62208, Replaces Veeder-Root # , -209

D Dissolution Units Mixing Training Course P/N Rev. C

Mixing Training Course P/N Rev. D

Hello. Classic. User s manual

KC22/32 SERIES Sealless Non-Metallic Centrifugal Pumps Installation and Maintenance Instructions

CF35 # INSTALLATION & OPERATION

Installation Instructions. Remanufactured Veeder-Root Steel Tank Interstitial Sensor. PMP # 62420, Replaces Veeder-Root # , -460

Use & Care Guide. Get the most from your new Keurig brewer

SPIFE Touch. Operator's Manual. Gel Electrophoresis and Processing. Catalog Number 1068, 120 Vac Catalog Number 1069, 240 Vac

Mariner Microspray and Low-Flow Electrospray Fused Silica Spray Tip and Capillary Kit. Operating Instructions. 1 Product Description.

MACHINE FROZEN CONCOCTION. Les meilleures margaritas sont originaires de Margaritaville

1. Conduct yourself in a responsible manner at all times in the laboratory.

Contents. Product Description. Features. Quick Guide. Touch Panel Operation. Instruction. How to change the filter. Warning.

Megaruptor. DNA Shearing System USER MANUAL. Megaruptor. Version 2. Cat. No. B

Operator s Manual. Histology Bath

H-10PM. Refrigerant Leak Detector

Eco-Safe Digester. Installation Manual For E3 Series Digesters. Version 1.6 Published: Apr. 13, 2017

Requests for Daily Care and Maintenance

INSTRUCTION MANUAL FOR Freeze Dry Systems PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION

Dry Contact Probe DCP (#30008)

OWNER S INSTRUCTION & INFORMATION

User and Installation Instructions. Wall Mounted Water Boiler WMB3F/B and WMB3F/W IS435 ECN3461

CALIBRATABLE 3-FUNCTION THERMO- HYGROMETER USER S MANUAL

Operator s Manual. The FREEDOM ROCKER. Contents. Congratulations!

KC22/32 SERIES Sealless Non-Metallic Centrifugal Pumps Installation and Maintenance Instructions

MIX Boiler & Font Range Service Manual

Contents. Product Description. Features. Quick Guide. Touch Panel Operation. Instruction. How to change the filter. Warning.

NXT Hg5 Amalgam Separator Installation and Operations Manual

SEC-MALS Noise Assessment and Cleaning Guide

Transcription:

QUICK REFERENCE Ion PGM Hi Q View Sequencing Kit Catalog Numbers A30044 Pub. No. MAN0014584 Rev. B.0 Note: For safety and biohazard guidelines, see the Safety appendix in the Ion PGM Hi Q View Sequencing Kit User Guide (Pub. No. MAN0014583). Read the Safety Data Sheets (SDSs) and follow the handling instructions. Wear appropriate protective eyewear, clothing, and gloves. Create a Planned Run... 1 Condition the Wash 2 Bottle for first use... 1 Cleaning... 2 Initialize the Ion PGM System... 3 Load the chip and start the sequencing run... 4 Limited product warranty... 6 Create a Planned Run Planned Runs can be created with the following software programs for use on the following systems: Software Torrent Suite Software, v5.0.4 or later Torrent Suite Assay Development Software, v5.0.2 or later Instrument System Ion PGM System Ion PGM Dx System IMPORTANT! If you are using the Ion PGM Dx System with Torrent Suite Assay Development Software [1], see the following user bulletins: Ion PGM Hi Q View OT2 Kit on the Ion OneTouch Dx System in Assay Development Mode User Guide (Pub. No. MAN0015753) and Ion PGM Hi Q View Sequencing Kit on the Ion PGM Dx System in Assay Development Mode (Pub. No. MAN0015792) Planned Run set-up and the Ion PGM Dx System workflow differ from those described in this user guide. Create a Planned Run in Torrent Suite Software 1. Open Torrent Suite Software for the Torrent Server connected to your sequencer. 2. Select the Plan tab, then select Templates. 3. Select the application in the left navigation bar (for example, AmpliSeq DNA). A list of existing Planned Run templates for that application will be displayed. Select one of the following options to create a new plan: To create a new Planned Run without using an existing template, click on Plan New Run. To create a new Planned Run from an existing template, click the button for the template and select Plan Run from the drop-down menu. Other options may be available depending on the selected application, such as downloading templates from AmpliSeq.com. 4. In the wizard, make your selections on each screen, then click Next to proceed to the next screen. 5. When you have completed your selections, click Plan Run. Condition the Wash 2 Bottle for first use New Wash 2 Bottles must be conditioned with Wash 2 Bottle Conditioning Solution for at least 8 hours before first use. To condition the Wash 2 Bottle: 1. Fill the bottle to the mold line with 18 MΩ water, add the entire container of Wash 2 Bottle Conditioning Solution, then cap the bottle and invert it 5 times to mix. 2. Allow the bottle to sit at room temperature for at least 8 hours and preferably overnight, then dispose of the contents. The bottle is now ready for use. [1] The Ion PGM Dx System with Torrent Suite Assay Development Software is For Research Use Only. Not for use in diagnostic procedures. For Research Use Only. Not for use in diagnostic procedures.

Cleaning 18 MΩ water cleaning 1. Empty any remaining solution from each cleaning bottle (two 250-mL bottles and one 2-L bottle) and rinse each bottle twice with ~100 ml of 18 MΩ water. 2. Press Clean on the touchscreen, and select the 18-MOhm water cleaning checkbox. Press Next. 3. Using ungloved hands, secure a used chip designated for cleaning in the chip clamp. IMPORTANT! Always make sure that both red rubber gasket port fittings are securely in place when securing chips with the chip clamp. Failure to do so can result in a spill hazard and instrument damage. 4. Remove all wash and reagent bottles attached to the instrument. Keep the sippers in place at all positions. Press Next. 5. Add 250 ml of 18 MΩ water to an empty 250-mL cleaning bottle. 6. Rinse the outside of the sipper tube in the W1 position on the instrument with a squirt bottle containing 18 MΩ water. 7. Attach the 250-mL bottle containing 18 MΩ water to the W1 position, ensuring that the W1 cap is screwed on tightly. Press Next. 8. Place the empty 2-L cleaning bottle in the W2 position and the empty 250-mL bottle in the W3 position, and insert the sippers into the bottles. Do not screw on the caps. 9. Place collection trays below the reagent sippers in the dntp positions. Press Next to begin cleaning. 10. When cleaning is complete, remove the bottles and sippers from the W1, W2 and W3 positions. Leave the reagent sippers and collection trays in place. Press Next to return to the main menu and proceed to initialization. Chlorite cleaning 1. Empty any remaining solution from each cleaning bottle (two 250-mL bottles and one 2-L bottle), then rinse each bottle twice with ~100 ml of 18 MΩ water. 2. Fill a glass bottle with 1 L of 18 MΩ water, then add an Ion Cleaning tablet (chlorite tablet). Allow the tablet to dissolve completely (~10 minutes). 3. When the tablet has dissolved, add 1 ml of 1 M NaOH and filter the solution using a 0.22-µm or 0.45-µm filter. Use the chlorite solution within 2 3 hours. Discard any unused solution after this time. 4. Press Clean on the touchscreen, then select the Chlorite cleaning checkbox. Press Next. 5. Using ungloved hands, secure a used chip designated for cleaning in the chip clamp. IMPORTANT! Always ensure that both red rubber gasket port fittings are securely in place when securing chips with the chip clamp. Failure to do so can result in a spill hazard and instrument damage. 6. Remove all wash and reagent bottles that are attached to the instrument. Keep the sippers in place at all positions. Press Next. 7. Add 250 ml of the filtered chlorite solution to an empty 250-mL cleaning bottle. 8. Rinse the outside of the sipper tube in the W1 position on the instrument with a squirt bottle containing 18 MΩ water. 9. Attach the 250-mL bottle with the filtered chlorite solution to the W1 position. Ensure that the W1 cap is tight. Press Next. 10. Place the empty 2-L cleaning bottle in the W2 position and the empty 250-mL bottle in the W3 position, then insert the sippers into the bottles. Do not screw on the caps. 11. Place collection trays below the reagent sippers in the dntp positions. Press Next to start cleaning. 12. When prompted, remove the bottle containing the chlorite solution from the W1 position. 13. Rinse the outside of the W1 sipper tube with a squirt bottle containing 18 MΩ water. 14. Fill a clean 250-mL bottle with 250 ml of 18 MΩ water, then attach the bottle in the W1 position. Ensure the cap is tight. Press Next to start the water rinse. 15. When cleaning is complete, remove the bottles and sippers from the W1, W2 and W3 positions. Leave the reagent sippers and collection trays in place. Press Next to return to the main menu, then proceed to initialization. 2 Ion PGM Hi Q View Sequencing Kit Quick Reference

Initialize the Ion PGM System Before initialization 1. Remove the dntp stock solutions from the freezer and begin thawing on ice. 2. Check the tank pressure for the nitrogen gas. When the tank pressure drops below 500 psi, change the tank. Prepare the Wash 2 Bottle IMPORTANT! Do not let the new sippers touch any surfaces. 1. Rinse the Wash 2 Bottle (2 L) 3 times with 200 ml of 18 MΩ water. 2. Prepare 500 µl of 100 mm NaOH by diluting 50 µl of 1 M NaOH in 450 µl of nuclease-free water. 3. If your 18 MΩ water system has a spigot, extend it into but not below the neck of the Wash 2 Bottle. Otherwise, position the nozzle as close to the mouth of the bottle as possible. 4. Fill the bottle to the mold line with 18 MΩ water. The volume of water is ~2 liters. (You can mark the mold line on the bottle for clarity.) 5. Add the entire bottle of Ion PGM Hi-Q View Sequencing W2 Solution to the Wash 2 Bottle. 6. Using a P200 pipette, add 70 µl of 100 mm NaOH to the Wash 2 Bottle. 7. Cap the bottle and invert 5 times to mix, and immediately proceed through the remainder of the initialization procedure. IMPORTANT! Do not store the mixed Wash 2 Bottle. Prepare the Wash 1 and Wash 3 Bottles 1. Rinse the Wash 1 and Wash 3 Bottles three times with 50 ml of 18 MΩ water. 2. Wash 1 Bottle: Add 350 µl of freshly prepared 100 mm NaOH to the Wash 1 Bottle, then cap the bottle. 3. Wash 3 Bottle: Add Ion PGM Hi-Q View Sequencing W3 Solution to the 50-mL line marked on the Wash 3 Bottle, then cap the bottle. Begin the initialization IMPORTANT! Do not let the new sipper tubes touch any surfaces. 1. On the main menu, press Initialize. 2. Make the following selections in the next screen and then press Next: Click Enter barcode to scan or enter the barcode on the Ion PGM Hi-Q View Sequencing W2 Solution bottle, or the 2D barcode on the Ion PGM Hi-Q Sequencing Solutions box. Alternatively, select the checkbox for the Ion PGM Hi-Q View Sequencing Kit from the dropdown list. In the same screen, if you routinely experience clogging during initialization, select the Line Clear checkbox to clear any blockage in the fluid lines before initialization. This is optional. After you press Next, the system will check the gas pressure. 3. Following the gas pressure check: Result If the pressure is sufficient If the pressure is low Action Confirm that the cleaning chip, reagent sipper tubes, and collection trays are in place, and press Next to begin the initialization Press Yes to re-check the pressure. If the pressure remains low, contact Technical Support 4. Wearing clean gloves, firmly attach a new, long gray sipper to the cap in the W2 position. 5. Immediately attach the prepared Wash 2 Bottle in the W2 position and tighten the cap. Press Next. 6. Change gloves and firmly install new sipper tubes (short gray) in the caps in the W1 and W3 positions. 7. Immediately attach the prepared Wash 1 and 3 Bottles and tighten the caps. Press Next. 8. Following line clear, or if you did not select that option, the sequencer will begin adjusting the ph of the W2 Solution, which takes ~30 minutes. After 15 minutes, check the instrument touchscreen to confirm that initialization is proceeding normally. Prepare the 50 ml Reagent Bottles with dntps 1. Use the labels provided with the kit to label four new Reagent Bottles as dgtp, dctp, datp, and dttp. 2. Confirm that no ice crystals are visible in each thawed dntp stock solution. Vortex each tube to mix, and centrifuge to collect the contents. Keep the dntp stock solutions on ice throughout this procedure. IMPORTANT! To avoid cross-contamination in the next step, open only one dntp stock tube at a time and use a fresh pipette tip for each aliquot. Ion PGM Hi Q View Sequencing Kit Quick Reference 3

3. Using separate filtered pipette tips and clean gloves, carefully transfer 20 µl of each dntp stock solution into its respective Reagent Bottle. 4. Cap each Reagent Bottle and store on ice until you are ready to attach it to the instrument. Place the remaining dntp stocks back into 20 C for storage. Attach the sipper tubes and Reagent Bottles 1. After the wash solutions have initialized, follow the touchscreen prompts to remove the used sipper tubes and collection trays from the dntp ports. 2. Change gloves, then firmly insert a new sipper tube (blue) into each dntp port. Do not let the sipper touch any surfaces. 3. Attach each prepared Reagent Bottle to the correct dntp port (e.g., the dgtp tube on the port marked "G") and tighten firmly by hand until snug. Press Next. 4. Follow the touchscreen prompts to complete initialization. The instrument will fill each Reagent Bottle with 40 ml of W2 Solution. 5. At the end of initialization, Ion PGM System will measure the ph of the reagents: If every reagent is in the target ph range, a green Passed screen will be displayed. If a red failure screen appears, see the troubleshooting section of the user guide. 6. Press Next to finish the initialization process and return to the main menu. 7. Proceed to the appropriate sequencing protocol for your chip type. Load the chip and start the sequencing run Use the following chip loading and sequencing protocol for all Ion PGM chip types. Before starting Thaw the Sequencing Primer on ice. Add controls to the enriched, template-positive ISPs 1. Vortex the Control Ion Sphere Particles, then pulsecentrifuge in a picofuge for 2 seconds before taking aliquots. 2. Add 5 µl of Control ISPs directly to the entire volume of enriched, template-positive ISPs (prepared using your template preparation method) in a 0.2-mL non-polystyrene PCR tube. 3. Proceed to "Anneal the Sequencing Primer". Anneal the Sequencing Primer 1. Mix the tube containing the ISPs by thoroughly pipetting up and down. 2. Place the tube in a microcentrifuge with an appropriate tube adapter. Orient the tab of the tube lid so that it is pointing away from the center of the centrifuge, to indicate where the pellet will be formed. 3. Centrifuge for 2 minutes at 15,500 g. 4. Keeping the pipette plunger depressed, insert a pipette tip into the tube containing the pelleted ISPs and carefully remove the supernatant from the top down, avoiding the side of the tube with the pink ISP pellet (that is, the side with the tab on the tube lid). Discard the supernatant. Leave ~15 µl in the tube (visually compare to 15 µl of liquid in a separate tube). 5. Ensure that the Sequencing Primer is completely thawed before use (no ice crystals should be visible). 6. Vortex the primer for 5 seconds, then pulse-centrifuge in a picofuge for 3 5 seconds to collect the contents. Leave on ice until ready to use. 7. Add 12 µl of Sequencing Primer to the ISPs, then confirm that the total volume is 27 µl (add Annealing Buffer if needed). 8. Pipet the mixture up and down thoroughly to disrupt the pellet. 9. Program a thermal cycler for 95 C for 2 minutes and then 37 C for 2 minutes, using the heated lid option. 10. Place the tube in the thermal cycler, then run the program. After cycling, the reaction can remain in the cycler at room temperature (20 30 C) while you set up the sequencing run. Perform Chip Check 1. On the main menu of the Ion PGM Sequencer touchscreen, press Run. Remove the waste bottle and completely empty it. Press Next. 2. When prompted to insert a cleaning chip, use the same used chip that was used for initialization. Press Next to clean the fluid lines. 3. When prompted, select the instrument that you used to prepare the template-positive ISPs. Then press Next. 4. Remove gloves, then ground yourself by touching the grounding pad on the sequencer. Remove a new chip from its packaging, then label it to identify the experiment (save the chip package). Press Next. 5. When prompted, use the scanner to scan the barcode located on the new chip, or press Change to enter the barcode manually. Optionally, you can also enter the library kit catalog number. 4 Ion PGM Hi Q View Sequencing Kit Quick Reference

6. Replace the old chip in the chip socket with the new one. Close the chip clamp, then press Next. 7. Press Chip Check. During the initial part of Chip Check, visually inspect the chip in the clamp for leaks. 8. Following a successful Chip Check, empty the waste bottle, then select the Waste bottle is empty checkbox on the touchscreen. Press Next. Bind the Sequencing Polymerase to the ISPs 1. Remove the Ion PGM Hi-Q View Sequencing Polymerase from storage and flick mix with your finger tip 4 times. Pulse-centrifuge for 3 5 seconds. Place on ice. 2. After annealing the Sequencing Primer, remove the ISPs from the thermal cycler, then add 3 µl of Ion PGM Hi-Q View Sequencing Polymerase to the ISPs, for a total final volume of 30 µl. 3. Pipet the sample up and down to mix, then incubate at room temperature for 5 minutes. Prepare and load the chip Remove liquid from the chip 1. Following chip calibration, remove the new chip from the Ion PGM Sequencer. Insert a used chip in the chip clamp while loading the new chip. 2. Tilt the new chip at a 45 angle so that the loading port is the lower port. 3. Insert the pipette tip firmly into the loading port, then remove as much liquid as possible from the loading port. Discard the liquid. 4. Place the chip upside-down in the minifuge bucket, then transfer the bucket with the chip tab pointing in (toward the center of the minifuge). Balance the bucket with another chip. 5. Centrifuge for 5 seconds to empty the chip completely. 6. Remove the chip from the bucket, then wipe the bucket with a disposable wipe to remove any liquid. Place the chip rightside up in the bucket. Load the chip 1. Place the chip in the bucket on a firm, flat surface. Following polymerase incubation, load the chip with following volume of prepared ISPs using the listed pipettes, or equivalent, depending on your chip type. We recommend using a P20 pipette for Ion 314 Chips for optimal loading. Chip Ion 316 or Ion 318 Chip Ion 314 Chip Volume to load Entire volume (~30 µl) Recommended pipette [1] Rainin Pipet-Lite LTS L-100XLS, 10 100 µl 10 µl Rainin Pipet-Lite LTS L-20XLS, 2 20 µl [1] Alternatives from Gilson and Eppendorf can be used. 2. Insert the tip firmly into the loading port of the chip. 3. With the pipette unlocked, apply gentle pressure between the tip and chip and slowly dial down the pipette (~1 µl per second) to deposit the ISPs. To avoid introducing bubbles into the chip, leave a small amount in the pipette tip (~0.5 µl). 4. Remove, then discard any displaced liquid from the other port of the chip. 5. Transfer the chip in the bucket to the minifuge with the chip tab pointing in (toward the center of the minifuge), then centrifuge for 30 seconds. 6. Turn the chip so that the chip tab is pointing out (away from the center of the minifuge), then centrifuge for 30 seconds. 7. Remove the bucket from the minifuge, then place it on a flat surface. Set the volume of the pipettor as follows, depending on your chip type: Ion 316 or Ion 318 Chip: 25 µl Ion 314 Chip: 5 µl 8. Tilt the chip at a 45 angle so that the loading port is the lower port, then insert the pipette tip into the loading port. 9. Without removing the tip, slowly pipet the sample out and then back into the chip one time. Pipet slowly to avoid creating bubbles. 10. Slowly remove as much liquid as possible from the chip by dialing the pipette. Discard the liquid. 11. Turn the chip upside-down in the bucket, transfer it back to the minifuge, then centrifuge upside-down for 5 seconds. Remove and discard any liquid. 12. If some liquid remains in the chip, lightly and rapidly tap the point of the chip tab against the benchtop a few times, then remove and discard any collected liquid. Do not flush the chip. 13. When chip loading is complete, press Next on the touchscreen, then proceed immediately to performing the run. Ion PGM Hi Q View Sequencing Kit Quick Reference 5

Select the Planned Run and perform the run Select the Planned Run 1. Press Browse next to the Planned Run field and select the name of the plan you created, then touch Next. Note: The Ion PGM Sequencer automatically populates this field for barcoded Ion chips. 2. Confirm that the settings are correct. If necessary, make any changes using the touchscreen controls. Perform the run 1. After you enter the Planned Run, press Next to verify the experimental setup. Press OK to confirm the settings or press Cancel to return to the touchscreen to adjust the settings. 5. After 60 seconds, the run will automatically begin, or press Next to begin the run immediately. 6. When the run is complete, leave the chip in place, then touch Next to return to the Main Menu. You can then remove the chip and proceed with another run or perform a cleaning/initializing if required. Limited product warranty Life Technologies Corporation and/or its affiliate(s) warrant their products as set forth in the Life Technologies' General Terms and Conditions of Sale found on Life Technologies' website at www.thermofisher.com/us/en/home/global/terms-andconditions.html. If you have any questions, please contact Life Technologies at www.thermofisher.com/support. 2. When prompted by the instrument, load and clamp the chip, then press Next. 3. At the beginning of the run, visually inspect the chip in the clamp for leaks before closing the cover. The instrument will flush any loose ISPs from the chip and begin calibrating the chip. 4. When the calibration is complete (~1 minute), the touchscreen will indicate whether calibration was successful. The information in this guide is subject to change without notice. DISCLAIMER: TO THE EXTENT ALLOWED BY LAW, LIFE TECHNOLOGIES AND/OR ITS AFFILIATE(S) WILL NOT BE LIABLE FOR SPECIAL, INCIDENTAL, INDIRECT, PUNITIVE, MULTIPLE, OR CONSEQUENTIAL DAMAGES IN CONNECTION WITH OR ARISING FROM THIS DOCUMENT, INCLUDING YOUR USE OF IT. Corporate entity: Life Technologies Corporation Carlsbad, CA 92008 USA Toll Free in USA 1 800 955 6288 2016 Thermo Fisher Scientific Inc. All rights reserved. All trademarks are the property of Thermo Fisher Scientific and its subsidiaries unless otherwise specified. For support visit thermofisher.com/support or email techsupport@lifetech.com thermofisher.com 31 August 2016