Owner & Installation Manual

Similar documents
Installation Manual. Conergy TS Open and Closed Systems.

Owners Manual Conergy Pty Ltd Split System Open and Closed Systems

CONERGY PTY LTD. Conergy TS Owner & Installation Manual

SOLAR NOW INTERNATIONAL PTY LTD. Envirosun AS Owner & Installation Manual

Alternate Energy Technologies, LLC PO Box Jacksonville, FL INSTALLATION OPERATION MAINTENANCE MANUAL THERMOSIPHON FREE-FLOW

Owner s Manual. Installation Details Owner s Information. 80L to 400L Electric Storage Water Heaters

OWNER S MANUAL WARRANTY INFORMATION AND INSTALLATION INSTRUCTIONS PROFLO AND MARATHON ELECTRIC STORAGE WATER HEATERS

Owner s Manual. Installation Details Owner s Information Warranty. 25L and 50L Electric Storage Water Heater

Owner s Manual. Installation Details Owner s Information Warranty. Electric Storage Water Heaters

OWNER S GUIDE. Electric and Gas Storage Water Heaters. Safety Information Owner s Information Warranty. Models

INDIRECT SYSTEM FOR FROST LOCATIONS

Roof Mount Solar Hot Water System USER MANUAL

Owner s Manual. Installation Details Owner s Information Warranty. 4 Star Gas Hot Water Heater 135ZB4N / 135ZB4P 170ZB4N / 170ZB4P

Owner s Manual. Installation Details Owner s Information Warranty. Pre Boosted Gas Solar Water Heater MP15 DL15DS DN15CS DL15CS

CENTRA-COIL QUALITY HOT WATER SERVICE

Owner s Manual. Installation Details Owner s Information Warranty. 4 Star Gas Hot Water Heater 170ZN / 170ZL

Installation Instructions

Operation / Installation Manual

INSTALLATION GUIDE AND WARRANTY INFORMATION

INSTALLATION INSTRUCTIONS OWNERS GUIDE & WARRANTY STATEMENT

SOLAR WATER HEATING DIRECT SYSTEM FOR FROST-FREE LOCATIONS DOMESTIC SOLAR WATER HEATERS, SOLAR COLLECTOR PANELS & SOLAR VACUUM TUBES

EVERLAST - SERIES 2000

SOLARGAIN HOT WATER User Manual

USER MANUAL INSTALLATION INSTRUCTIONS WARRANTY REGISTER

Includes Installation Instructions. Solahart Industries Pty Ltd ABN

Owner s Guide and Installation Instructions

Installation Instructions

OWNER S MANUAL SOLAR WATER HEATERS

Installation and Owner s Manual

OWNER S MANUAL SOLAR WATER HEATERS. Solahart Industries Pty Ltd ABN

PERFECT ORIENTATION ZONE 40 E 40 W GOOD GOOD ORIENTATION ZONE ORIENTATION ZONE

INSTALLATION MANUAL Roof Mount Solar Hot Water System

CROWN WATER HEATERS CPU10 - CPU15 CPOS10 - CPOS15

POWERFLOW Series. Unvented Electric Storage Water Heaters. Installation & Operating Instructions Manual

Powerflow Unvented water heater

SOLARHOT. SuperVox. Description / Applications System Overview. Installation/ Owner s Manual

Installation and Operating Instructions. Budget priced instant boiling water heater for beverages.

GEOTHERMAL STORAGE TANKS

ZIP Varipoint III. Installation, Maintenance and User Instructions. Models VP303, VP503 VP803, VP953 direct unvented water heaters. Issued August 2008

STEAM WALLPAPER STRIPPER MODEL HTW5

Zip Hydroboil. Installation and Operating Instructions. Filtered instant boiling water

Zip Econoboil. Installation and Operating Instructions. Budget priced instant boiling water for canteens and kitchens.

INSTALLATION MANUAL Ground Mount Solar Hot Water System

Operation / Installation Manual

MariGlo LED. Inspiring Excellence in Fish Keeping! 45 / 60 / 90 / 120.

INSTALLATION AND OPERATING INSTRUCTIONS

Operation / Installation Manual

INSTANTANEOUS ELECTRIC SHOWER

Parts Identification and Accessories Safety Information Installation Control Panel Layout Fully Automatic Washing...

aquamanta the experts in aquatic technology CH 025/050/100/ 150/200/300 NEW PHOTO Instruction Manual

Operation & Installation Manual

Seaward Products OWNER S MANUAL WATER HEATERS. Serial Number:

Pole Mounting System Installation & Certification Manual

Models: GHF4135N GHF4170N

Owner's Care & Maintenance Guide

Speedflow Undersink Unvented Water Heater. Models SF05K, SF10K and SF15K. Instruction Manual

Models: GHF4135N GHF4170N

Installer s Guide IMPORTANT INFORMATION Read This Document First On completion, sign and leave with owner

Low pressure copper indoor cylinders

Owner s Guide and Installation Instructions Air Sourced 310 Heat Pump Water Heater

Evacuated Tube Solar Hot Water System. Owners Manual. Version 5.4

Owner s Guide and Installation Instructions Commercial Storage Tank

Apricus Solar Hot Water Owner s Operating and Maintenance Manual For Electric Hot Water Tanks (Solar-Ready)

Installation guide Billi B-3000 Sparkling Dual levered slimline tap option

Owner s Guide and Installation Instructions

INSTALLATION GUIDE NZ AU C

Unvented Calorifier Range. Operating and Maintenance Manual. For Models & 500

Unvented Electric Water Heater 10/15 litre Undersink

Pole Mounting System Installation & Certification Manual

Owner s Guide and. Gas Continuous Flow Water Heater 27L Gas Water Heater 874 & 872 Series, 627 Models

Solar Hot Water - Naturally the smarter choice

BOILING UNIT REDITAP. Installation and User Guide. IMPORTANT: This booklet should be left with the user after installation and demonstration

Owner s Guide and Installation Instructions

Electronically controlled instantaneous water heater. MCX: 27300, and models. Installation instructions

Glass Chimney Hood. Installation & User Instructions Please keep for future reference

Operation / Installation Manual

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

Read this manual before you start to use this equipment. SAFETY WARNING! Important Safety instructions.

Installation Manual Universal Top-of-Pole Mount UNI-TP/08LL

HEATRAE SADIA. Installation and User Instructions for the UTC Undersink Vented Water Heater

WH-TD20B3E5 WH-TD30B3E5

Installation Manual Universal Top-of-Pole Mount UNI-TP/02

INSTALLATION INSTRUCTIONS

J120 STEAM BOOSTER INSTALLATION, OPERATION, AND SERVICE MANUAL J120 STEAM BOOSTER. J120 Steam Booster Manual D

Operation / Installation Manual

Owner s Guide and Installation Instructions

WARRANTY BOOKLET. Commercial Hot Water. Register online at

Zip Chillmaster Floor Mounted Chiller

Installation, operating and servicing instructions

INSTRUCTIONS MODEL: MWBT

HOT WASHER MODEL NO: KING150

INSTALLATION GUIDE NZ AU

model NO. LSS GALLON SKID MOUNTED HIGH PRESSURE SPRAYER ASSEMBLY / OPERATION INSTRUCTIONS / PARTS

ELECTRIC RADIANT OUTDOOR / INDOOR HEATER

WARRANTY BOOKLET. Solar Hot Water. Register online at

aquamanta the experts in aquatic technology

Table of Contents. Features Quality Policy Section A - Unit Operation Section B Unit Maintenance Trouble Shooting Guide...

Installation, Operating and Maintenance Guide

Zip Tudor. Affix Model Number Label Here Installation Section & Operating Heading Instructions. Single point open outlet (vented) water heaters

Installation Manual Thermosiphon - Indirect

Transcription:

Owner & Installation Manual Conergy TS Open and Closed Circuit Systems www.conergy.com.au

Table of Contents Table of Contents 1 1.1 Customer Information The environmental benefits 2 2 1.2 Why Conergy? 2 1.3 How does the system work? 2 2 Installation Information 5 2.1 Conergy TS model number explained 5 2.2 Important safety information 5 2.3 If the customer is away for a period of time 6 2.4 Water discharge through the pressure valve 6 3 Troubleshooting 7 3.1 Low solar energy input 7 3.2 Solar collector shading 7 3.3 Booster system not operating 7 3.4 Excessive water discharge from the valves? 7 3.5 Using more hot water than anticipated? 7 3.6 Water discharge from frost valve 8 4 System Maintenance 9 5 Installation Instructions 10 5.1 Typical open circuit assembly diagram 10 5.2 Typical system assembly 10 5.3 Connection and mounting part kits 11 5.4 Roof location selection 11 5.5 Supplementary heat sources 12 5.6 Common installation procedure 12 5.7 System installation 13 5.8 System diagrams and components 14 5.9 Plumbing connections - Open Circuit models 23 5.10 Plumbing connections Closed Circuit models 24 5.11 Draining the storage tank 25 5.12 Filling the Closed Circuit jacket 25 5.13 Electrical installation instructions 27 5.14 Gas (AES) installation instructions 28 6 Commissioning & Customer Hand Over 29 7 ANNEX - Mounting frame for flat roof 30 8 Warranty 32 Conergy TS Owner & Installation Manual

1 Customer Information 1 Customer Information You are installing one of the most advanced solar water heaters in the world. This manual provides you with the essential information needed to install the Conergy Thermosiphon System correctly. Please read it carefully and follow all the instructions. We hope you find the following information useful. 1.1 The environmental benefits A Conergy solar water heater is an excellent and economic energy solution. By using the sun s heat to heat our water, we cut down on the amount of fossil fuels needed to be burnt to supply electricity to do the same. 1.2 Why Conergy? Conergy offers Australia s largest range of renewable energy products and our company operates in 25 countries on 5 continents. Our products are used in 100 000 s of Solar Home Systems for Hot Water and Solar Electricity worldwide and we offer the leading products in this technology. Before you can sell in Australia, or achieve any of the State or Federal Government rebates, your product must comply with the rigorous Australian Standards for solar water heaters. Our products comply with all these standards. The Federal Government Renewable Energy Certificate program, called RECs, is an indication of solar efficiency. If you compare any of the Conergy products with an equal competitor model, you will find that Conergy systems often achieve more RECs than our competitors. 1.3 How does the system work? Under normal operating conditions the potable water within the potable storage tank is heated by the solar collectors. For example, in an open circuit system where the household hot water is in the collector circuit, cold water is pushed downwards via the long external pipe from the storage tank to the bottom of the solar collector. As the water is heated in the absorber by the sun, it rises to the top of the collector then travels through the short external pipe into the storage tank. The Conergy TS solar water heater is supplied in kit form so that the installer can assemble and connect the solar water heater in various configurations to suit the installation location and user requirements. Typically the kit contains the four main components of your solar water heater system which are the potable water storage tank, the solar collector(s), the Ancillary Energy Support (AES) System and the parts box, containing pipes fittings and mounting rails to interconnect and mount the system. Please note the AES system can be either electric or gas operated dependent on the model purchased. Conergy TS Owner & Installation Manual

1 Customer Information 1.3.1 Storage Tank & Solar Collectors Conergy TS 300 litre vitreous enamel tank LC collector The potable water storage tank is used to store the heated water ready for household use. It is constructed using high quality vitreous enamel lined low carbon steel to provide long life. The tank is insulated with a high density polyurethane material to ensure minimal heat losses and maximmum structural strength. The solar collectors contain a multi tube copper water way system bonded to a solar absorber plate, the combination of which collects solar energy and transfers it to the fluid within the collector circuit. The absorber plate system is enclosed in an insulated metal casing covered with a high strength toughened glass sheet that protects the absorber system from physical damage. 1.3.2 Ancillary Energy Support (AES) - Booster System Electricity and gas are the two options for the AES system. An electric Ancillary Energy Support (AES) system uses an electric element to heat part of the stored household water on those occasions when there is reduced solar energy available e.g. cloudy days. The electricity supply to the electric AES, located within the storage tank, is automatically controlled by an internal thermostat. This thermostat will only allow the electric element to operate if the storage tank water temperature falls below 60 o C. It will only consume electricity until the water temperature is increased to 60 o C. At this stage, it will turn off automatically. Conergy TS Owner & Installation Manual

1 Customer Information For gas AES systems the electric element in the storage tank is not connected to an electricity supply. Instead a continuous flow gas water heater is fitted in series with the hot water supply from the storage tank and the household hot water pipe system. As the hot water from the solar storage tank passes through the gas heater its temperature is automatically monitored. If the temperature is below 60 C, the gas heater will add the heat required to deliver hot water of at least 60 C. If the water temperature is above 60 C, the gas heater is programmed not to ignite. Conergy TS Owner & Installation Manual

2 Installation Information 2 Installation Information 2.1 Conergy TS model number explained XX NNN / N / X / XNN / X / XNNXX System Type - Nominal Volume - Collector Area - Tank Type - Booster - Tank Material - Collector Type Variable Categories System Type AS Active Systems (pumped) Nominal Volume HP TS Nominal Storage Volume Heat Pump System Type Thermosiphon, TS Collector Area 2, 2.5, 4, 5, 6 Nominal Collector Area Tank Type O Open Circuit C Closed Circuit Booster E Electric Tank Material / Designation Collector Type G XX V S M Gas Booster Rating (kwx10 or Lpm) Vitreous Enamel Stainless Steel Millenium Tank E20SB, E20BC, E25BC or F20LC 2.2 Important safety information All water heaters have the ability to produce hot water very quickly. To reduce the risk of scald injury it is recommended that a temperature control valve be fitted to the hot water supply pipe work. This valve should be checked every 6 months to ensure its operation and settings remain correct. Please check that the pressure & temperature relief valve relief pipe is not located where it can cause damage if hot water is discharged. This water heater is not intended for use by young children, infirm persons, or persons lacking relevant skill or experience, without suitable supervision. Children should be supervised to ensure they do not play with hot water taps or the water heater. For closed circuit systems, if the water seems red in appearance it could mean that there is a leakage of glycol from the jacket into the main water tank. Please contact your authorised Conergy dealer or installation service provider as soon as possible. Conergy TS Owner & Installation Manual

2 Installation Information Hydrogen gas can accumulate! If the hot water system is not used for two weeks or more, a quantity of hydrogen gas, which is highly flammable, may accumulate in the water heater. To dissipate this gas safely, it is recommended that a hot tap be turned on for several minutes at a sink, basin or bath but not a dishwasher, clothes washer, or other appliance. During this procedure there must be no smoking, open flame or any other electrical appliance operating nearby. If hydrogen is discharged through the tap, it will probably make an unusual noise as with air escaping. Do not place hands or any part of your body beneath the tap during this procedure. 2.3 If the customer is away for a period of time If the system is not to be used for a period of a week or more during the summer months it is advisable to turn off the electricity supply to the booster and if practical, cover the solar collectors. If the solar collectors are not covered there is a possibility that the high temperature valve in the storage tank may open and disperse small amounts of hot water for a short period to reduce the storage tank temperature while you are away. This is a normal function and does not harm the system. 2.4 Water discharge through the pressure valve All Conergy solar water heaters have two pressure valves located within the system configuration. The cold water expansion valve, located in the cold water supply pipe, may release a small amount of water from time to time during the heating cycle of the system. The water discharge is water expanding due to the heating process. Normally the discharge will be less than 10 litres per day. The pressure & temperature valve, located on the storage tank, may also release a small expansion discharge. Conergy TS Owner & Installation Manual

3 Troubleshooting 3 Troubleshooting What to check for during service calls If there is not enough hot water we recommend that the following points are considered as part of the service call. The most obvious reasons for a lack of hot water could be one of the following: 3.1 Low solar energy input If there have been prolonged periods of cloud or winter is approaching, it may be necessary to reconsider the permitted boosting time for time-clock controlled systems or to turn on the booster for systems with a booster isolation switch. 3.2 Solar collector shading Often trees or other buildings can shade the solar collectors or there can be a dirt build-up on the glass cover. Trees should be cut back if possible or the system relocated if removal of the shading is not possible in the present location. If the glass is dirty this should be cleaned with standard domestic glass cleaner. If rainwater collection occurs from the same roof on which the solar water heater is located, do not use chemical cleaning agents to clean the collectors. Any spillage of these onto the roof could cause contamination of water in the rainwater tank. 3.3 Booster system not operating For electric systems the fuse or circuit breaker supplying the AES System should be checked. If the time clock (where fitted) and the fuse or circuit breaker are operational and the water is cold, you can turn the booster isolator on and off to see if the electricity meter speed changes. If there is no change in speed, it indicates there may be a booster problem. Contact your authorised Conergy dealer or installation service provider as soon as possible. For gas systems the gas and electric supplies to the gas heater should be checked to ensure they are both on. If water temperature from the gas heater is below 60 C and both supplies are on and the gas heater does not ignite there may be a problem. Contact your authorised Conergy dealer or installation service provider as soon as possible. 3.4 Excessive water discharge from the valves? If there is a discharge of more than 10 litres per day from any of the systems valves, it indicates there may be a problem with the valve or an increased water supply pressure. Contact your authorised Conergy dealer or installation service provider as soon as possible. 3.5 Using more hot water than anticipated? Often the hot water usage of showers, washing machines and dishwashers is underestimated by the customer. Review these appliances to determine if the daily usage is greater than the storage volume of the water heater. Depending on the model, our TS system tanks contain 180 or 300 litres of hot water therefore if the customer s usage is greater than 300 litres within a short period of time, there may be periods where the water temperature is slightly lower than normal. It is also advisable to inspect hot water tap washers etc. for leakage and replace if necessary. Conergy TS Owner & Installation Manual

3.6 Water discharge from frost valve If your system has a frost valve fitted it will be located at the bottom corner of the collector. In temperatures that cause frost or freezing the valve will open and some water will discharge from this valve. There is nothing that needs to be done to the valve or the system, it is operating correctly. The water will stop discharging once the valve has warmed enough to close again, usually as the frost clears. Conergy TS Owner & Installation Manual

4 System Maintenance 4 System Maintenance The Conergy system is designed such that there is little to do regarding system maintenance. Should you decide that you want to inspect the roof mounted system it is essential that you use all safety devices required to ensure your personal safety. Glass cleaning usually occurs by natural rainfall, however if the installation is in an industrial (or similar) area with high levels of airborne particles then a qualified person can clean the collector glass with normal window cleaning chemicals and equipment. If rainwater collection occurs from the same roof on which the solar water heater is located, do not use chemical cleaning agents to clean the collectors. Any spillage of these onto the roof could cause contamination of water in the rainwater tank. In the unusual case that the toughened glass collector covers are broken, Conergy does not advise replacement of the glass. The entire panel should be replaced to maintain the performance and integrity of the water heater. Replacement panels should be installed by a qualified person. The lever on the relief valves should be operated at least every six months. Failure to do so may result in failure of the tank. If water does not discharge freely from the valves they should be checked and possibly replaced. The relief valves and relief valve drain lines must not be blocked. Some water may discharge during each heating cycle. Every five years all safety valves should be replaced to ensure continued life and operational safety of the system. In locations where the potable water has a Total Dissolved Solids (TDS) of greater than 600 ppm it is recommended to replace all safety valves every 3 years. The high quality vitreous enamel lined low carbon steel tanks have a sacrificial anode for long tank life. This anode should be inspected every few years and be replaced when it has worn out. As a minimum it is recommended that the anode be changed every 5 years. Conergy TS Owner & Installation Manual

5 Installation Instructions Important Notes DO NOT commence an installation until you have satisfied yourself that all safety issues associated with working on and lifting components onto a roof have been addressed. All work associated with the installation must comply with local authority regulations including AS/NZS 3500.4.2. Where these installation instructions and local regulations are in conflict, local regulations must prevail. 5.1 Typical open circuit assembly diagram 5.2 Typical system assembly The table below indicates the system components: Module Number Tank Collector Model Number Tank Collector TS180/2/0/E24/V/F20LC TS180/0/E24 1 x F20LC TS180/2/C/E24/V/E20BC TS180/C/E24 1 x E20BC open circuit closed circuit TS180/2/0/E24/V/E20BC TS180/0/E24 1 x E20BC TS180/2/C/E24/V/E20SB TS180/C/E24 1 x E20SB open circuit closed circuit TS180/2/0/E24/V/E20SB TS180/0/E24 1 x E20SB TS300/4/C/E24/V/E20BC TS300/C/E24 2 x E20BC open circuit closed circuit TS300/4/0/E24/V/F20LC TS300/0/E24 2 x F20LC TS300/4/C/E24/V/E20SB TS300/C/E24 2 x E20SB open circuit closed circuit TS300/4/0/E24/V/E20BC TS300/0/E24 2 x E20BC open circuit TS300/4/0/E24/V/E20SB TS300/0/E24 2 x E20SB open circuit 10 Conergy TS Owner & Installation Manual

5.3 Connection and mounting part kits The table below indicates the connection and mounting kits required for each model system: Module Number Parts Kit TS180/2/O/E24/V/E20BC TS180/2/O/E24/V/E20SB TS180/2/C/E24/V/E20BC TS180/2/C/E24/V/E20SB TS180/2/O/E24/V/F20LC TS300/4/O/E24/V/E20BC TS300/4/O/E24/V/E20SB TS300/4/C/E24/V/E20BC TS300/4/C/E24/V/E20SB TS300/4/O/E24/V/F20LC PK-2100 PK-2101 PK-2100 PK-2102 PK-2103 PK-2102 5.4 Roof location selection There are five major factors to consider when selecting the solar water heater installation location: For optimum performance the solar collectors need to face the equator (in Southern hemisphere this is north and in the Northern hemisphere this is South). Installation on angles of up to 45 away from the equator do not have a major effect on the annual solar output, consequently roof locations which face less than 45 away from the equator are acceptable. If the collectors are installed with an east facing bias the best solar input is achieved in the morning and if there is a west facing bias the best solar input is in the afternoon. Careful site inspection is required to ensure the selected location is not subjected to shading from adjacent trees or buildings throughout the day, but particularly between 9am and 3pm, the highest solar input times. Shadows are longer in winter than in summer so a site that is free of shadows from adjacent objects in summer may have some shadows in winter. The solar water heater should be located as close as possible to the location which uses the most hot water eg. bathroom or kitchen. This is to reduce energy losses which may occur if the pipe work between the solar water heater and the point of usage is too long. To achieve optimum performance the solar water heater should be installed on a roof pitch of greater than 8 and less than 30. Installations on a roof where the roof pitch is greater than 30 will require additional support at the storage tank to prevent it moving downward during and after installation. If the roof pitch is less than 8 the system will require a mounting frame to increase the pitch above 8. Installations below 8 do not thermosiphon effectively and the collector glass will not self clean during rainy periods. Conergy TS Owner & Installation Manual 11

The roof system must be carefully inspected to ensure it can support the systems weight once it is filled with water. Particular care must be taken where the front foot of the storage tank is located. Typically the tank front foot should be located over a tile batten, purlin or similar for maximum strength. If the roof can not support the load, additional bracing must be installed before the solar water heater is installed. 5.5 Supplementary Heat Sources If a supplementary heat source is connected to the storage tank the maximum energy input can be not more that 10 kw including the electrical element. Where greater input is required, a pressure and temperature relief valve with a higher kw rating is to be fitted to the storage tank. Where stove coils are used for supplementary heating the water must be connected in an open vented manner. Refer to Australian Standard AS3500 for more details on acceptable connection solutions. Any supplementary heat source must be limited such that the maximum tank temperature is 80 C. For the interconnecting details e.g. pipe work of your specific model/configurations please check the assembly drawings in the following pages. 5.6 Common installation procedure 5.6.1 Determining mounting location The starting point for the installation is the storage tank front foot. The storage tanks front foot must be located over a tile batten or purlin for maximum strength. The batten or purlin selected must be located at least 2.4 metres up from the roof s lower edge and 1 metres down from the roof s ridge line so that the ridge caps are not disturbed. 1. 2. Place the tank into position with its front foot centrally over the selected tile batten. The tank should be installed after the collectors are installed. The tank centre should be installed over rafters/trusses evenly so as to spread the tank weight over an even area of the roof. Measure down the roof from the right side front edge of the front foot a distance of 2030 mm and make a mark on the roof tile. This position (Point 2 of mounting location) will be the bottom edge of the collector mounting rail. 12 Conergy TS Owner & Installation Manual

5.7 System Installation Note: Installation of solar water heaters in Australia requires a tempering valve on the hot water supply from the unit for correct installation and safe temperature regulation. Please note that the detail letters referred to in the installation text refer to the diagrams on page 14 and onwards. 1. Place one end of the bottom collector mounting rail (Detail E) at the location marked before (refer to point 2) and lay horizontally across the roof to the left. 2. Locate two roof trusses which are under the collector mounting rail (as near as possible to the outer edges of the rail). Slide two collector straps (Detail E) onto the collector mounting rail where the trusses pass under the mounting rail. 3. Adjust the mounting rail so that it is horizontally across the roof then raise it 5 10 mm on the right side. 4. Screw fix the collector straps to the roof trusses using the prepunched holes in the collector straps. 5. Take the first solar collector and place it on the collector mounting rail, at the left most end. 6. Loosely fit the two collector connectors (Detail D) to the two copper tube spigots on the right side of collector. 7. Take the second collector and place it onto the right hand side of the collector mounting rail. 8. Now, slide collector toward the first collector until the two copper tube spigots of that collector slide fully home into the collector connectors already fitted to collector. 9. Tighten the compression nuts of the collector connector fittings (Detail D) taking care not to twist the copper tubes of the collector. Make sure you use correctly sized spanners and that the centre nut is held steady whilst the compressing nuts are tightened. 10. Move the two collectors so that they are centrally located on both the collector mounting rail and the tank. 11. Using 4 of the self drilling screws supplied screw fix the collector rail to the collectors as shown in details D and E. Finally using 2 of the self drilling screws supplied and screw fix the collector straps to the collector rail and collectors as shown in Detail E. 12. Slide a Compression Plug assembly (Detail A) to the top left corner of the collector array. Tighten the assembly taking care not to twist the copper tubes of the collector. 13. For open circuit models slide a Compression Plug assembly (Detail E) to the bottom right corner of the collector array. Tighten the assembly taking care not to twist the copper tubes of the collector. 14. For closed circuit models slide the Fill Fitting assembly (Detail E) to the bottom right corner of the collector array. Tighten the assembly taking care not to twist the copper tubes of the collector. 15. Fit the Cold Pipe connection pipe (Detail A and C) to the bottom left corner of the collector array and the storage tank tube fitting as shown on the model configuration drawing following. 16. Install the Hot Pipe assembly as shown in Detail B between the top right corner of the collector array and the storage tank tube fitting as shown in Detail B. When the assembly is in place tighten all fittings. 17. Insert the P&T valve supplied with the Parts Kit into the valve port in the tank as shown in Detail A. Conergy TS Owner & Installation Manual 13

18. 19. 20. For closed circuit models insert the 100 kpa closed circuit pressure relief valve into the ½ tank socket as shown in Detail A. Note this valve is not used on open circuit models. Using the straps supplied with the Parts Kit place one into each side of the tank front foot as shown in Detail A. back leg so that they are over a rafter then screw fix in place to the rafter to secure the tank in place. Take the straps under the tank and screw fix to the roof rafter. Finally take the tank clamp and bolt it to the tank strap behind the tank so that the tank clamp secures the tank to the tank strap. To complete the security screw fix the 2 tank clamps to the tank using the 2 self drilling screws provided. 5.8 5.7.1 5.8.1 Flat Roof Installations For flat roof installations a special mounting frame is required (For more information see Annex at end of manual) Once the frame is mounted please follow the installation as outlined above. System diagrams and components * Model TS300/4/O/XX/X/F20LC * Represents all AES and tank options. 14 Conergy TS Owner & Installation Manual

Components of model TS300/4/O/XX/X/F20LC * Item No. Part No. Description Qty 1 2LC-T-ZA Collector, Solar, F20LC 2 2 60-1002 Union, Compression, 22mm, Sub-Assy 2 3 60-1003 Union, RP3/4 - C22mm, Sub Assy 1 4 60-1004 Plug, Compression, 22mm, Sub Assy 2 5 60-1138 Valve, P&T, 700kPa 1 6 60-1083 Union, Collector Elbow, Thermosiphon, Sassy 1 7 60-1122 Union, Cold Inlet Tee, RP3/4 xc3/4 xc22mm, Extended, SAssy 1 8 60-1129 Cold Pipe, 304/LC/O/XX, SAssy 1 9 60-1130 Hot Pipe, 304/LC/O/XX, SAssy 1 10 60-3028 Rail, Collector, Steel Angle, 2 Panel 1 11 60-4000 Strap, Mounting, Tank, Type A 2 12 60-4004 Clamp, Mounting, Tank, Type A 2 13 60-4011 Strap, Collector, Type C 2 14 75-4000 Nut, Hex, SS, M8 x 1.25 2 15 75-4001 Washer, Plain, Stainless Steel, M8 2 16 75-4002 Set Screw, Hex, SS, M8 x 1.25 x 20 2 17 75-4016 Screw, Self Drilling, Pan, SS, CR, #8 x 13mm 8 18 S300/O/KE Tank, Assembly, TS300/O/V 1 * Represents all AES and tank options. Conergy TS Owner & Installation Manual 15

5.8.2 * * Models TS300/4/O/XX/X/E20BC, TS300/4/O/XX/X/E20SB Components * * Represents all AES and tank options. 16 Conergy TS Owner & Installation Manual

Item No. Part No. Description Qty 1 60-1002 Union, Compression, 22mm, Sub-Assy 2 2 60-1003 Union, RP3/4 - C22mm, Sub Assy 1 3 60-1004 Plug, Compression, 22mm, Sub Assy 2 4 60-1138 Valve, P&T, 700kPa 1 5 60-1086 Union, Collector Elbow 2, Thermosiphon, SAssy 1 6 60-1121 Union, Cold Inlet Tee, RP3/4 xc3/4 xc22mm, SAssy 1 7 60-1125 Cold Pipe, 304/BC/X/XX, SAssy 1 8 60-1128 Hot Pipe, 304/BC/O/XX, SAssy 1 9 60-3028 Rail, Collector, Steel Angle, 2 Panel 1 10 60-4000 Strap, Mounting, Tank, Type A 2 11 60-4004 Clamp, Mounting, Tank, Type A 2 12 60-4011 Strap, Collector, Type C 2 13 75-4000 Nut, Hex, SS, M8 x 1.25 2 14 75-4001 Washer, Plain, Stainless Steel, M8 2 15 75-4002 Set Screw, Hex, SS, M8 x 1.25 x 20 2 16 75-4016 Screw, Self Drilling, Pan, SS, CR, #8 x 13mm 8 17 E20 Solar Collector, E20BC, E20SB 2 18 S300/O/KE Tank, Assembly, TS300/O/V 1 5.8.3 Models TS300/4/C/XX/X/E20BC, * TS300/4/C/XX/X/E20SB * * Represents all AES and tank options. Conergy TS Owner & Installation Manual 17

* * Components of model TS300/4/C/XX/X/E20BC, TS300/4/C/XX/X/E20SB Item No. Part No. Description Qty 1 60-1002 Union, Compression, 22mm, Sub-Assy 2 2 60-1003 Union, RP3/4 - C22mm, Sub Assy 2 3 60-1004 Plug, Compression, 22mm, Sub Assy 1 4 60-1009 Valve, Caleffi, 100kPa 1 5 60-1138 Valve, P&T, 700kPa 1 6 60-1119 Union, Fill Fitting, 22mm, SAssy 1 7 60-1120 Union, Collector Elbow 3, Thermosiphon, SAssy 2 8 60-1125 Cold Pipe, 304/BC/X/XX, SAssy 1 9 60-1126 Hot Pipe, 304/BC/C/XX, SAssy 1 10 60-3028 Rail, Collector, Steel Angle, 2 Panel 1 11 60-4000 Strap, Mounting, Tank, Type A 2 12 60-4004 Clamp, Mounting, Tank, Type A 2 13 60-4011 Strap, Collector, Type C 2 14 75-4000 Nut, Hex, SS, M8 x 1.25 2 15 75-4001 Washer, Plain, Stainless Steel, M8 2 16 75-4002 Set Screw, Hex, SS, M8 x 1.25 x 20 2 17 75-4016 Screw, Self Drilling, Pan, SS, CR, #8 x 13mm 8 18 E20 Solar Collector, E20BC, E20SB 2 19 S300/C/KE Tank Assembly, TS300/C/V 1 * Represents all AES and tank options. 18 Conergy TS Owner & Installation Manual

5.8.4 Model TS180/2/O/XX/X/F20LC * Components * * Represents all AES and tank options. Conergy TS Owner & Installation Manual 19

Item No. Part No. Description Qty 1 2LC-T-ZA Solar Collector F20LC 1 2 60-1003 Union, RP3/4 - C22mm, Sub Assy 1 3 60-1004 Plug, Compression, 22mm, Sub Assy 2 4 60-1138 Valve, P&T, 700kPa 1 5 60-1083 Union, Collector Elbow, Thermosiphon, SAssy 1 6 60-1121 Union, Cold Inlet Tee, RP3/4 xc3/4 xc22mm, SAssy 1 7 60-1131 Cold Pipe, 182/BC/C/XX, SAssy 1 8 60-1134 Hot Pipe, 182/BC/O/XX, SAssy 1 9 60-3030 Rail, Collector, Steel Angle, 1 Panel 1 10 60-4000 Strap, Mounting, Tank, Type A 2 11 60-4004 Clamp, Mounting, Tank, Type A 2 12 60-4011 Strap, Collector, Type C 2 13 75-4000 Nut, Hex, SS, M8 x 1.25 2 14 75-4001 Washer, Plain, Stainless Steel, M8 2 15 75-4002 Set Screw, Hex, SS, M8 x 1.25 x 20 2 16 75-4016 Screw, Self Drilling, Pan, SS, CR, #8 x 13mm 6 17 S180/O/KE Tank Assembly, TS180/O/V 1 5.8.5 Models TS180/3/O/XX/X/E20BC, * TS180/2/O/XX/X/E20SB * * Represents all AES and tank options. 20 Conergy TS Owner & Installation Manual

* * Components of model TS180/3/O/XX/X/E20BC, TS180/3/O/XX/X/E20SB Item No. Part No. Description Qty 1 60-1003 Union, RP3/4 - C22mm, Sub Assy 1 2 60-1004 Plug, Compression, 22mm, Sub Assy 2 3 60-1138 Valve, P&T, 700kPa 1 4 60-1083 Union, Collector Elbow, Thermosiphon, SAssy 1 5 60-1121 Union, Cold Inlet Tee, RP3/4 xc3/4 xc22mm, SAssy 1 6 60-1133 Cold Pipe, 182/BC/O/XX, SAssy 1 7 60-1134 Hot Pipe, 182/BC/O/XX, SAssy 1 8 60-3030 Rail, Collector, Steel Angle, 1 Panel 1 9 60-4000 Strap, Mounting, Tank, Type A 2 10 60-4004 Clamp, Mounting, Tank, Type A 2 11 60-4011 Strap, Collector, Type C 2 12 75-4000 Nut, Hex, SS, M8 x 1.25 2 13 75-4001 Washer, Plain, Stainless Steel, M8 2 14 75-4002 Set Screw, Hex, SS, M8 x 1.25 x 20 2 15 75-4016 Screw, Self Drilling, Pan, SS, CR, #8 x 13mm 6 16 E20 Solar Collector, E20BC, E20SB 1 17 S180/O/KE Tank Assembly, TS180/O/V 1 * Represents all AES and tank options. Conergy TS Owner & Installation Manual 21

5.8.6 Models TS180/3/C/XX/X/E20BC, * TS180/2/C/XX/X/E20SB * Components * * Represents all AES and tank options. 22 Conergy TS Owner & Installation Manual

Item No. Part No. Description Qty 1 60-1003 Union, RP3/4 - C22mm, Sub Assy 2 2 60-1004 Plug, Compression, 22mm, Sub Assy 1 3 60-1009 Valve, Caleffi, 100kPa 1 4 60-1138 Valve, P&T, 700kPa 1 5 60-1083 Union, Collector Elbow, Thermosiphon, SAssy 2 6 60-1119 Union, Fill Fitting, 22mm, SAssy 1 7 60-1131 Cold Pipe, 182/BC/C/XX, SAssy 1 8 60-1132 Hot Pipe, 182/BC/C/XX, SAssy 1 9 60-3030 Rail, Collector, Steel Angle, 1 Panel 1 10 60-4000 Strap, Mounting, Tank, Type A 2 11 60-4004 Clamp, Mounting, Tank, Type A 2 12 60-4011 Strap, Collector, Type C 2 13 75-4000 Nut, Hex, SS, M8 x 1.25 2 14 75-4001 Washer, Plain, Stainless Steel, M8 2 15 75-4002 Set Screw, Hex, SS, M8 x 1.25 x 20 2 16 75-4016 Screw, Self Drilling, Pan, SS, CR, #8 x 13mm 6 17 E20 Solar Collector, E20BC, E20SB 1 18 S180/C/KE Tank Assembly, TS180/C/V 1 5.9 Plumbing connections - Open Circuit Models 5.9.1 Cold water connection A check valve and a stop cock must be fitted to the cold water supply pipe work. 1. The cold water connection is made at the blue disc. Connect the cold water supply to the end of the ¾ BSP female thread of the Tee piece in the cold down pipe assembly (Detail A). 2. Where the water supply pressure is greater than 550 kpa, a 500 kpa pressure limiting valve must be fitted to limit the supply pressure. 5.9.2 Cold water expansion relief valve Fit the 600 kpa pressure relief valve, supplied in the Parts Box, in the cold water supply pipe after the check valve, stop cock and (if required) pressure limiting valve. 5.9.3 Hot water connection Use the ¾ BSP x 22mm fitting, supplied in the Parts Kit, to connect the hot water supply to the storage tank outlet connection (Detail A) marked with a red disc. Conergy TS Owner & Installation Manual 23

5.9.4 Pressure & temperature relief valve (P&T valve) Remember this valve can discharge very hot water, so carefully consider its location. Never discharge onto a solid surface like concrete. 1. Fit the 700 kpa/99 C (10 kw) pressure & temperature relief valve supplied in the parts box into the ½ brass tank socket, marked with the brown disc, adjacent to the hot outlet tube as shown in (Detail A). 2. Ensure that the drain line from the pressure and temperature relief has a continuous downslope and falls away from the valve and towards the ground level to a safe location, terminating above the ground level. Please ensure that the drain is installed in a place where it cannot be affected by freezing conditions (per AS3500). 5.10 Plumbing connections Closed Circuit Models 5.10.1 Cold water connection 1. 2. Fit the ¾ BSP x 22 mm fitting supplied in the parts kit to the copper tube in the storage tank marked with the blue disc (Refer Detail A). Then connect the cold water supply to the ¾ BSP thread of that fitting. It is mandatory that a check valve and stop cock are fitted to the cold water supply pipe work. Where the water supply pressure is greater than 550 kpa, a 500 kpa pressure limiting valve must be fitted to limit the supply pressure. 5.10.2 Cold water expansion relief valve The cold connection is made at the copper connection marked with the blue disc. Fit the 600 kpa pressure relief valve, supplied in the Parts Box, in the cold water supply pipe after the check valve, stop cock and (if required) pressure limiting valve assembly. 5.10.3 Hot water connection Use the ¾ BSP x 22mm fitting, supplied in the Parts Kit, to connect the hot water supply to the storage tank outlet connection marked with a red disc. 5.10.4 Pressure & temperature relief valve (P&T valve) Remember this valve can discharge very hot water, so carefully consider its location. Never discharge onto a solid surface like concrete. 1. 2. Fit the 700 kpa/99 C (10 kw) pressure and temperature relief valve supplied in the parts box into the ½ brass tank socket marked with the brown disc adjacent to the hot outlet tube as shown in (Detail A). Ensure that the drain line from the pressure & temperature relief has a continuous downslope and falls away from the valve and towards the ground level to a safe location, terminating above the ground level. Please ensure that the drain is installed in a place where it cannot be affected by freezing conditions (per AS3500). 24 Conergy TS Owner & Installation Manual

5.11 Draining and flushing the storage tank collectors The Conergy storage tank should be drained and flushed every five years during a major service of the unit. Open circuit units should have the collectors flushed at the same time. 1. Turn off and isolate the power supply to the electrical element. 2. Turn off the water supply to the water heater. 3. 4. 5. 6. Release excess pressure from the tank by manually opening the pressure & temperature relief valve. Disconnect the cold water supply pipe connection to the tank. Fit a ½ flexible drain pipe to the cold connection at the tank. Place the open end of the drain hose in a location where it is safe for the hot water to drain away from the tank. Manually open the pressure & temperature relief valve which will allow air into the tank and the water within the tank will flow out via the flexible drain pipe fitted to the cold inlet connection. Hold the valve open until the tank is empty. To drain the open circuit collectors, disconnect the cold pipe from the bottom left of the collector array. NOTE: This process should not be applied to Closed circuit systems. To Flush the unit, repeat the filling and draining processes at least once. If there is a need to clean the waterways, an appropriate, potable water safe, cleaning fluid may be used by a qualified person, in accordance with local regulations. 5.12 Filling the Closed Circuit jacket Risk of damage to the elements can occur if the installation sequences are not maintained. When filling the jacket with glycol it is essential that the main tank is filled with water and pressurised prior to filling the closed circuit. Do not apply power to the electric booster element before the tank is filled with water. Do not fill the closed circuit system with any toxic solution. Only use the solar transfer fluid as specified by your Conergy TS distributor. There is a real risk to public health if the wrong glycol solar solution is used. Approved Solar Transfer Fluid details Name: St-5 Solar Transfer Fluid Description: Propylene Glycol Appearance: Red Liquid To ensure adequate frost protection, use the following quantity of ST-5 to maintain glycol above 40% of solution: TS 180/C system: 1 bottle - 4.5 litres total TS 300/C system: 2 bottles - 9 litres total When you are ready to fill the system please have the following equipment ready to fill and test the system: 1 x 25 litre container 1 x Pressure Test Block 1 x 4 metre length of ½ (15mm) 1 x Bicycle Pump ST-5 solar transfer fluid supplied with the system Conergy TS Owner & Installation Manual 25

5.12.1 Fill and test information and procedure Cover Collectors for this procedure to prevent pressure variation due to thermal activity in the collectors. The solar transfer fluid is of food grade and non toxic. However, care must be taken when handling not to spill or accidentally consume. Always use the solar transfer fluid as specified by Conergy and outlined above. Every care must be taken to ensure that in installations where rain water is being collected from the same roof, any spilt ST-5 solution is cleaned up immediately so that the ST-5 solution does not contaminate the water in the rain water storage tank. 1. Remove the 100 kpa jacket relief valve from the tank socket. See Detail A for the location of this valve. 2. Connect a ½ (12 mm) flexible hose to the fill tap located at the bottom right side of the collector array. See Detail D for the location and the photo to the right for detail. 3. With the aid of a funnel and hose connected to the fill tap, pour the contents of the heat transfer fluid container into the funnel (4.5 litres) then add drinking grade water until the fluid flows from the 100 kpa jacket relief valve socket in the tank. See drawing below for the detail. Detail D - Fill tap 4. Close the fill tap and insert the pressure test block into the tank s 100 kpa jacket relief valve socket. To the right is a photo of the pressure test block. Pressure test block Jacket relief valve (Detail A) Funnel Hose Fill tap (Detail D) 26 Conergy TS Owner & Installation Manual

5. 6. 7. Using a bicycle pump or similar connected to the jacket relief valve, as shown to the right, pressurise the system to 120 kpa. Check all fittings for signs of leaks and tighten if required. Check over a 10 minute period that the pressure on the test gauge remains unchanged. 8. 9. Once the circuit is free from leaks, release the pressure in the system through the pressure test block valve fitting then unscrew the pressure test block from the tank socket. Refit the 100 kpa jacket relief valve into the tank socket from which the pressure test block was removed. 10. The system is now operational and the covers can be removed from the collectors. The heat transfer fluid should be checked every five (5) years and replaced if necessary. 5.13 Electrical installation instructions For safe performance this water heater is fitted with a thermostat and an over temperature cut-out. These devices should not be tampered with or removed. Do not operate this water heater without the electrical thermostat and over temperature cut-out in the circuit. Note: Risk of damage to the elements can occur if the installation sequences are not maintained. All electrical work must comply with local regulations. All electrical work must be conducted by a suitability licensed electrician. 5.13.1 Electrical Connection for Electric AES Systems The electric element is only connected in models using an electric AES system. No connection is made to the electric element for gas AES systems. The electrical booster requires a 220 250 volt single phase AC power supply with a capacity suitable for the kilowatt rating of the element selected for the application. eg. a 2.4 kw element requires a 10 amp supply capacity, a 3.6 kw element requires 15 amp supply capacity. Electrical entry for the electric AES is achieved via a 16mm hole adjacent the element surround. A 16mm cable gland with orange circular cable, or 16mm conduit with 3 core tps cable shall be used to make electrical supply to the unit. The power supply must be protected by an individual fuse or circuit breaker rated to suit the booster size. The supply to the solar water heater can be operated directly from the switchboard or via a remotely mounted switch or time clock as requested by the customer. Conergy TS Owner & Installation Manual 27

A means for disconnection (eg isolator) must be included in the fixed wiring to the solar water heater in accordance with the wiring rules. Final electrical connection at the solar water heater is as follows: Earth - connected to the earthing stud marked with the earth symbol; Active - connected to the terminal block position marked A or Active; Neutral - connected to the terminal block position marked N or Neutral. Do not turn on the power supply until the solar water heater has been filled with water and pressurised. There is a risk of damage to the system if the installation sequence is not followed. 5.13.2 Electrical Circuit Diagram 5.13.3 Electrical Connection for Gas AES Systems For models using a gas AES system the electrician is required to install a domestic electrical outlet socket adjacent to the gas heater location. The gas heater requires a 220-240 volt 50 Hz powersupply and is rated at 0.47 amperes. 5.14 Gas (AES) Installation Instructions Note Important note: All gas work must comply with local regulations including AS5701/AG601 and AS/NZ 3500.4 All gas work must be conducted by a suitability licensed gas fitter. Installation of the gas heater must be installed in accordance with the installation instructions supplied with it. Conergy systems only use approved Gas Heaters. Particular attention must be given to the gas supply system to ensure the there is a sufficient gas supply available to the gas heater when operating at full output burner rate. 5.14.1 Approved Gas Heater Models Gas heater models used with Conergy solar water heater systems must be certified to all local requirements, be automatic ignition and have full flame modulation. Gas heaters other than this type must not be used with a Conergy solar water heater. Particularly fixed pilot and fixed flame models must not be used under any circumstance. Please refer to your local distributor for information on approved gas heater model. 28 Conergy TS Owner & Installation Manual

6 Commissioning & Customer Hand Over 6 Commissioning & Customer Hand Over When all connections have been completed the solar water heater can be filled with water. Before turning on the cold water supply open one hot tap within the household to release air from the system during the filling process. Do not leave the open tap unattended during the filling process. Turn on the cold water supply and wait for the system to fill. When water flows from the open hot tap without air bursts then the hot tap can be closed. This will now pressurise the solar water heater system. Once the system is pressurised all connections on the water heater must be checked for leaks and repaired if necessary. When the system is proven water tight, power and gas can be applied to the AES system. To test that the element is operational turn the circuit breaker in the switch board on and off, you should see the power meters speed change during this action. For gas AES systems turn on a hot water tap and the gas heater will ignite provided the water temperature is less than 60 C. Customer Hand Over The solar water heater is now fully operational. Once the solar water heater is commissioned and you are confident it is operating correctly, complete the installation details on the carbon copy sheet at the beginning of the owners manual. Please remove the Conergy (blue) and the installer (pink) copy. Please hand the owner the Owners Manual and Gas Heater Manual (if gas AES is used). Before leaving the installation ensure that the customer is fully aware of the systems operation and whom to contact should there be any questions in the future. Thank you for installing our world class Conergy solar water heater. Your Conergy Team Conergy TS Owner & Installation Manual 29

7 ANNEX - Mounting frame for flat roof 7 ANNEX - Mounting frame for flat roof 2BC = 2000mm 2B = 2000mm 2S = 2000mm 2SP = 2000mm 2LC = 1935mm Tank E D 800 C A B 2660 1500 Note: 1. Ensure tank is located directly over vertical support. 30 Conergy TS Owner & Installation Manual

7 ANNEX - Mounting frame for flat roof Item Article Description PK-1014 PK-2055, PK-2056, No. No. Qty PK-2057 Qty. 1 60-3000 Cross Brace, Unistrut P4000, 2 Panel Mounting Frames 2-2 60-3003 Bracket, 70, Mounting Frames 2-3 60-3004 Bracket, 90, Mounting Frames 2-4 60-3005 Base/Hypoteneuse, Unistrut P2000, Mounting Frames 4-5 60-3006 Upright, Unistrut P2000, Mounting Frames 2-6 60-3024 Bracket, 20, Mounting Frame 2-7 60-3028 Rail, Collector, Steel Angle, 2 Panel - 1 8 60-4004 Clamp, Mounting, Tank, Type A - 2 9 60-6007 Rail, Collector, Aluminium, 2 Panel 1-10 60-6008 Clamp, Collector Mount, Z 4-11 75-3009 Nut, Channel, ZP, M10 x 1.5 12-12 75-3010 Nut, Channel, ZP, M8 x 1.25 2-13 75-3028 Washer, Plain, ZP, M10 18-14 75-3030 Set Screw, Hex, ZP, 4.6, M10 x 1.5 x 25 18-15 75-3031 Nut, Hex, ZP, 4.6, M10 x 1.5 6-16 75-4000 Nut, Hex, SS, M8 x 1.25 4 2 17 75-4001 Washer, Plain, Stainless Steel, M8 4 2 18 75-4002 Set Screw, Hex, SS, M8 x 1.25 x 20 4 2 19 75-4016 Screw, Self Drilling, Pan, SS, CR, #8 x 13mm 4 8 Conergy TS Owner & Installation Manual 31

8 Warranty 8 Warranty The Conergy Solar hot water system that you have purchased comes with a comprehensive 5 year parts and labour warrantly. The terms of the Warranty and Guarantee are set out below. 1. 2. 3. 4. 5. 6 Your solar hot water system and its components are covered by a 5 year warranty against defective factory parts or workmanship from the date your hot water unit or solar collector is installed. If the date of installation is unknown, the warranty commences 1 month after the date of manufacture (which can be found on the serial plate on the hot water unit and solar collector). This warranty is for normal use of the solar hot water system and covers the repair and/or replacement of any failed component in the hot water unit and solar collector or where necessary, the hot water unit and solar collector itself. Under this warranty Conergy will repair or replace the component or hot water unit or solar collector free of charge (except for certain transport or travelling time costs which may be payable by the owner under clause 9 below). The decision to repair or replace the component or hot water unit or solar collector will be entirely at the discretion of Conergy. The warranty only applies to defects in the hot water unit and solar collector which have arisen solely due to faulty materials or workmanship. Installation of your Conergy solar hot water system is not covered under this product / manufacturers warranty and in cases of installation failure please contact your original installation service provider. 5 Year Guarantee If any component of the system fails during the initial 5 year warranty period Conergy will replace the failed components free of charge. (except for certain transport or travelling time costs which may be payable by the owner under clause 9 below). Scope of Warranty and Guarantee The warranty and replacement guarantee do not apply to any defects or damage not due to faulty factory parts or workmanship, installation, including but not limited to defects or damage caused by or resulting from: 6.1 6.2 6.3 6.4 6.5 6.6 6.7 6.8 6.9 Accidental damage, abuse, misuse, maltreatment, abnormal stress or strain, harsh or adverse water conditions, contamination or corrosion from particles in the water supply, excessive water pressure, over temperature or neglect of any kind to the hot water unit and solar collector or their components. Alteration or repair of the hot water unit or solar collector other than by an approved Conergy agent or a technician of a gas or electricity utility approved by Conergy. Attachment of any parts or accessories other than those manufactured or approved by Conergy. Faulty or improper installation of the hot water unit or solar collector, including installation otherwise than in accordance with the instructions contained in the Owner s Manual and Installation Manual supplied by Conergy. Collector glass is not covered by this warranty. Where cold water temperature & pressure relief valve, expansion valve, check valve and strainer is not fitted in areas where mains pressure is likely to exceed 550 kpa. Where a closed circuit is not filled with the correct concentration of ST-5 heat transfer fluid in accordance with instructions. In case of overpressure of closed circuit system beyond the 300kPa maximum working pressure. Where closed circuit has had water addition not in accordance with water quality specifications; and 32 Conergy TS Owner & Installation Manual

8 Warranty 6.10 Freeze damage to open circuit systems when installed in frost affected areas. 7. The warranty only applies to the hot water unit and solar collector or components in the hot water unit and solar collector and does not cover any plumbing or associated parts, including but not limited to; pressure limiting valves, stop cocks, non return valves, electrical switches, pumps or fuses, supplied by any person installing the hot water unit or solar collector. 8. 9. 10. Where a hot water unit and solar collector or a component in a hot water unit or solar collector is replaced by Conergy, the balance of any original warranty or replacement guarantee period will remain effective. The replacement part or hot water unit or solar collector does not carry any additional warranty or replacement guarantee. Where the solar hot water system is located outside the metropolitan area of a capital city and is: More than 25 kilometres from a Conergy office; or More than 25 kilometres from a Conergy agent. The owner will be responsible under the warranty, for paying the costs of transporting the hot water unit or solar collector or any component in the hot water unit or solar collector to and from an approved Conergy agent or to a Conergy office (including the costs of any insurance associated with that transport) or paying the travelling time of an approved Conergy agent to and from the owner s house premises. Where the warranty applies but the hot water unit and solar collector is installed or located in a position that does not comply with the installation instructions or any relevant statutory requirements, the owner of the solar hot water system will be responsible for the costs of: The dismantling or removal of cupboards, doors, walls of special equipment and; Any labour required to gain access to and to bring the system/unit to a position that complies with the installation instructions or relevant statutory requirements. 11. 12. 13. 14. Conergy s obligations under this warranty and guarantee are limited to repairing or replacing the hot water unit and solar collector or components. To the extent permitted by law, Conergy will not be liable for any loss or damage to furniture, carpets,. walls, foundations or any other consequential loss of any kind caused by a defect in the hot water unit and solar collector or any component. Any claim under the warranty or replacement guarantee must include full details of the defect and/or damage to the hot water unit and solar collector or components in the hot water unit and solar collector. All claims must be made within one month of the detection of the defect. In addition to this warranty and guarantee, certain legislation (including the Trade Practices Act 1974 and consumer protection legislation of the States and Territories) gives the owner certain rights, which cannot be excluded, restricted or modified. Nothing in this warranty and replacement guarantee has the effect of excluding, restricting or modifying those rights. In the case of a solar hot water system acquired for other than personal domestic or household use, Conergy s liability for a breach of a condition or warranty implied by Division 2 of Part V (other than Section 69) of the Trade Practices Act (1974) and any equivalent State or Territory legislation is expressly limited to any one or more of the following, as determined by Conergy: The replacement of the hot water unit and solar collector. The repair of the hot water unit and solar collector. The payment of the cost of replacing the hot water unit and solar collector or of acquiring an equivalent hot water unit and solar collector. Payment of the cost of having the hot water unit and solar collector repaired. Conergy TS Owner & Installation Manual 33