Monitoring Software for NPBC-V3M-1 User Manual

Similar documents
Electronic Pellet Burner Controller NPBC-V3M

Electronic Pellet Burner Controller NPBC-V3-1

Electronic pellet burner controller - NPBC-V3M. Electronic Pellet Burner Controller NPBC-V3M

Electronic Pellet Burner Controller NPBC-V3C-K NPBC-V4C-K

OPERATION MANUAL RK-2006LPP AUGER FITTED SOLID FUEL BOILER TEMPERATURE CONTROLLER. Version DC19

ENVI Boiler Controller

Operation Manual Fighter ProVision Software. Version: 0.0 Revision: 1

Service Settings. EASY PFA Universal Biomass Heating System Controller. Technical Documentation

INSTRUCTIONS FOR USE OF COMBINED BOILER INTENDED FOR COMBUSTION OF BOTH PELLETS AND SOLID FUEL ABC COMBO

Janfire Pellet Burner Boiler. for single / double burner management (Version 1.1)

EasyTech.One Temperature Controller for Pellet Burner

HIGH EFFICIENCY FIRETUBE CONDENSING GAS BOILER

LineGuard 2300 Program User Manual (FloBoss 107)

Cm Pelet-set (60-90 kw)

USER'S INFORMATION MANUAL

Ambient Temperature/ Relative Humidity & Dew Point Temperature Sensors to USB Output. Model LFS108B

ARITERM OY. Arimatic 500. User manual

Cm Pelet-set TECHNICAL INSTRUCTIONS FOR THE COMMISSIONING AND ADJUSTMENT. (14-35 kw) For boilers: EKO-CKB P (EKO-CKB 20-40)

Laptop / PC Programming Manual

HEATING TECHNIQUE. Centrometal d.o.o. - Glavna 12, Macinec, Croatia, tel: , fax: C O2=8% 80 C.

Diagnostics and Monitoring System WEB Tool 2. User Manual

STREBEL S-CB + Cascade Kits

USER'S INFORMATION MANUAL

CONTROL PANEL INTERFACE ACTIVATE THE GENERATOR DISPLAY INTERFACE MENUS. Control Panel USING THE AUTO/OFF/MANUAL SWITCH

Aqua Balance. AquaBalance TM CONTROL MODULE QUICK START GUIDE LEGEND

User manual. KNXgal. version

OPERATION MANUAL RK-2001W2 SOLID FUEL FIRED BOILER TEMPERATURE CONTROLLER. Version 9A15

PELLET BURNER PV 350

OVEN INDUSTRIES, INC.

Boiler controller SPS 4000

- Data Brochure Steam Control 279

Roth Touchline. German quality since Quick and easy user manual 1/10

INSTRUCTION MANUAL OF THE SIEMENS CLIMATIX 2 CONTROL EQUIPMENT

User Manual. Dryer Controller M720

E N G L I S H FIRE ALARM ASPIRATION SENSING TECHNOLOGY QUICK INSTALLATION GUIDE STAND-ALONE FAAST LT MODELS FL0111E FL0112E FL0122E. 367 mm.

THERMO BUTTON HYGRO BUTTON The smallest temperature and humidity loggers in the world!

LYNX SE CENTRAL CONTROL FOR NETWORK GDC. General Specifications

Installation Guide. ECL Comfort 210, application A Table of Contents

Boiler controller S-Tronic Plus

NGC-UIT2 MODBUS PROTOCOL INTERFACE MAPPING FOR NGC-30 SYSTEMS. Firmware versions up to V2.0.X

USER'S INFORMATION MANUAL

AFUE 95% Heating Input 50,000 to 200,000 Btuh

1 DOCUMENT REVISION SOFTWARE VERSION BASIC DESCRIPTION BASIC OVERVIEW OF HYDRAULIC DIAGRAMS HYDRAULIC DIAGRAMS...

Pellet burner PV 180a. User manual

User Guide: *IG1624EW*

Configuration and Operation Manual for the Unipos

User Manual. Digi-Sense TC9500 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

Declaration of Conformity no. 56/2012

GH10PA USER MANUAL. Program version 01 MANUAL FOR CONTROLLER FOR CONTROLLING CENTRAL HEATING BOILERS FIRED WITH PELLETS AND OATS

Power Flame Incorporated

Trinity Tft/Lx Model #s: Tft60-399/Lx Version Date:

USE AND MAINTENANCE. Cm Pelet-set (60-90 kw) TECHNICAL INSTRUCTIONS

Combined boiler. for solid fuel and pellets

Dryer Controller M720

ECL Comfort 210 controller, Remote Control Units ECA 30 / 31 and Application keys

REPEATER FS5200R INSTRUCTION MANUAL

FI6000 INSTRUCTION MANUAL. Thank you for choosing another quality product from Amperes Electronics. Fire Alarm Interface

PowerRouter application guideline

Rotem One Touch. User Manual PRELIMINARY DOCUMENT. Ag/MIS/UmGB /18 Rev 1.0 P/N:

ST 53.1 User s manual

SWEBO Bioenergy Manual pellet burner PB50 Rev no. Date Page PBM1: (37) Installation and maintenance instructions

ProCon 16, 31, 47 & 75. RVA 63 Boiler and Circuit Controller Commissioning Data.

Portable Dryer Touch Screen Controls

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

ROOM THERMOSTAT. with OpenTherm+ communication

User Manual. Digi-Sense TC9600 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

USER'S INFORMATION MANUAL

ECL Comfort 210 controller, Remote Control Units ECA 30 / 31 and Application keys Designed in Denmark

USER MANUAL S203. Controller for three circuits. - control for 2 heating circuits - 1 domestic hot water control. Saving energy, creating comfort

DI220 Using the Optional Docking Station The maintenance and operating functions of the Micro IV can be automated with the Micro IV Docking Station.

Sensor Control Panel

MODEL SF-10 CONTROL OPERATION AND INSTRUCTION MANUAL

User Guide: *IG1605EW*

Fridge-tag 2 E OPERATION MANUAL ENGLISH PAGE 1-36 MODE D EMPLOI FRANCAIS PAGE with internal sensor

Ion Gateway Cellular Gateway and Wireless Sensors

GLOBAL. InstallatIon & operation manual

OPERATING INSTRUCTIONS. G214 Software - Version 4

ENVI Boiler Controller

prestige Control Application Supplement - Type 5 MCBA WARNING

E N G L I S H FIRE ALARM ASPIRATION SENSING TECHNOLOGY QUICK INSTALLATION GUIDE ADDRESSABLE FAAST LT MODELS MI-FL2011EI, MI-FL2012EI AND MI-FL2022EI

EasyTech.Full Temperature Controller for Pellet Stove. Idro

Boiler controller Lambdatronic S 3200

multimatic Operating instructions AT, BE (de), CH (de), DE VRC 700f/4

Mounting and Operating Instructions EB 5610 EN. TROVIS 5600 Automation System TROVIS 5610 Heating and District Heating Controller

EBC20. Instructions for fitting, installation and operation. Read and save these instructions!

Cascade Sequencer. Control Installation and Operation Instructions. Infinite Energy Boiler Manual. Also read and follow: CS-IOM-1

1 DOCUMENT REVISION CONTROL ELEMENTS... 9

Fridge-tag 2 OPERATION MANUAL ENGLISH PAGE 1-35 GEBRAUCHSANWEISUNG DEUTSCH SEITE with external sensor

Vision for Portable Dryers

AK SM 800 Commissioning Guide

LYNX CE CENTRAL CONTROL FOR OSMAC. General Specifications

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless testing requires power.

Service Manual Models: 1.0, 1.3, and 1.5

JOVY SYSTEMS RE User Manual Rev. 1.00

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless testing requires power.

Fridge-tag 2 OPERATION MANUAL ENGLISH PAGE 1-36 GEBRAUCHSANWEISUNG DEUTSCH SEITE with internal sensor

TV2 Room Pressure Monitor Quick Start Guide

Ontech GSM 9040/50. Reference Manual English -1 -

iminiplus PDF User Guide Version 2.0

Alarm description DECS Contents

Transcription:

Monitoring Software for NPBC-V3M-1 User Manual User Manual ver 1.5 page 1 of 14

Contents: 1. Introduction... 3 2. Requirements... 3 3. Installing the software... 4 4. Connecting the devices... 4 5. Updating the controller's software... 4 5.1. Updating the software of the Executive module... 4 5.2. Updating the software of the Control module... 5 6. Settings...... 6 6.1. Main screen options... 6 6.2. Parameters settings... 8 7. Monitoring... 12 7.1. Fuel consumption... 12 7.2. Status chart... 12 7.3. Console... 13 8. Export files... 13 User Manual ver 1.5 page 2 of 14

1. Introduction: The software NPBC_Monitor.exe is designed for remote monitoring and control of the pellet burner controller NPBC-V3M-1. With this software you can easily monitor the performance and the current state of your burner, as well as to edit all the parameters needed to adjust the controller to a particular burner. Connect the controller to a computer, by using a suitable serial cable. Important advantages of the monitoring software: displays charts with the pellet consumption for the last 24 hours; displays a chart with the change-overs between the power levels of the burner's work; an option to export in text files the information about the burner's state every time it changes; each text file's name contains the date and time of the last record in it, which allows the user to monitor and compare the burner's performance for longer past periods. 2. Requirements: To work this software properly, you need a computer working on Windows OS (XP/Vista/7) with a serial interface RS-232. Also, you need a cable to connect NPBC-V3M-1 to the computer. Connection scheme for NPBC-V3M with PC The controller should be connected both to the supply voltage and to the computer. One of the procedures requires the controller to be turned off from the power supply and then back on again. It will be easier, if you provide a power switch near the workplace. User Manual ver 1.5 page 3 of 14

3. Installing the software: Make a directory on your computer (for example C:\NPBC-V3M_Monitor) and save the archive file there. Extract the files from the archive. Check the number of your serial interface (COM port). If it is different than COM1, open the file NPBC_Monitor.ini, find the line COM_PORT=COM1 and change the number 1 with the correct number. Save the file. Now you can run the program NPBC_Monitor.exe. To make it easier you can make a shortcut to the program on your desktop. 4. Connecting the devices: Connect the controller to the computer by using a suitable cable. If your computer does not have a serial interface RS-232, you can use a USB-to-RS232 cable. Connect the controller to the power supply and switch it on. 5. Updating the controller's software: It is recommended to update the software of the Executive module first and then software of the Control module. 5.1. Updating the software of the Executive module: Double-click on the message on the line SWver, which should indicate the current version of the Executive module: You will see the following Confirmation window: Click on the button OK. The next message lets you choose the module for software update: User Manual ver 1.5 page 4 of 14

Click on Yes. The software update requires some time, so don't worry if it takes a few minutes. While updating the software of the Executive module, its green LED blinks slower, which indicates the process. 5.2. Updating the software of the Control module: Double-click on the message on the line SWver, which should indicate the current version of the Executive module: You will see the following Confirmation window: Click on the button OK. The next message lets you choose the module for software update: Click on No. You will see an Information window: Follow the instructions from the message. While changing the software, a message Upgrading appears on the display. This process lasts a little bit longer than the software update of the Executive module. After the update is completed, the controller restarts. You might have to check, if it remembers all the previous settings, and if they have been changed, you will have to make them again. It is recommended not to turn off the power supply to the controller while the programs are being uploaded! User Manual ver 1.5 page 5 of 14

6. Settings: The monitoring software allows you to make all the settings you need through your computer, instead of the controller's Control module. 6.1. Main screen options: On the main screen of the program, you can make some general settings: Line Message Setting SWver Date/Time State Software version of the controller or HWid error if it is not compatible with the monitoring program. Shows the date and time in format: dd-mm-yyyy 23:59. The current work mode of the burner: Standby mode is indicated by a 'Standby' message, Auto mode is indicated by a message with the current installation with major priority and Programme mode is indicated by the same message as Auto, Double-click on the message to update the software of the controller. Double-click on the message. If the time is not set, the program gets the computer's system time and date. Double-click on the message. Two combo boxes and OK and Cancel buttons appear. Choose the work mode for the burner from the top combo box and the User Manual ver 1.5 page 6 of 14

Status NPBC-V3M Monitoring Software but with a time interval below it. The current state of the burner: Extinction, Ignition, Cleaning, Burning, Suspend, etc. installation with major priority from the bottom. Tset Set temperature of the boiler Double-click on the message to change the set temperature. Tboiler Current temperature of the boiler Tdhw Current temperature of the water heater Flame Current light level, measured by the IR photo sensor Tfume Temperature of the exhaust gases in the vent Thermostat Normal/Stop CH pump On/Off DHW pump On/Off Heater On/Off Total feed Errors Feeder Capacity RSSI The total fuel consumption by this moment since the time in the brackets, based on the feeder capacity. All the error message, which the controller might display on its screen, appear here, too. Fuel consumption per hour Progress bar, showing the strength of the signal when using a radio interface. Double-click on the message to reset it. Double-click on the message to enter the correct fuel consumption per hour corresponding to your burner. User Manual ver 1.5 page 7 of 14

6.2. Parameters settings NPBC-V3M Monitoring Software Before entering the parameter setting, the burner must be in State: STANDBY and Status: IDLE STANDBY, otherwise you wouldn't be able to save the changes. If it is currently working, change its work mode to Standby and wait until it is completely extinguished. Enter the parameters settings, by pressing the Settings button on the bottom right corner of the main window. User Manual ver 1.5 page 8 of 14

Cleaning on Start Cleaning on Stop Cleaning on BBAlarm Parameter Fan Cleaner Fan Cleaner Fan Cleaner Auto Cleaning After burning for Description Active time (in seconds) of the main fan for cleaning the burner before ignition Active time (in seconds) of the additional fan for cleaning the burner before ignition Active time (in seconds) of the main fan for cleaning the burner after extinction Active time (in seconds) of the additional fan for cleaning the burner after extinction Active time (in seconds) of the main fan for cleaning the burner when BBAlarm occurs Active time (in seconds) of the additional fan for cleaning the burner when BBAlarm occurs Cycle for the automatic cleaning procedures. Ignition Retries Number of attempts to ignite the pellets Initial Feed Heater Fan1 Fan2 Fan, column 3 Initial Burning Duration Burning Startup Power Modulation Fan speed, column 1 Fan speed, column 2 P1 P2 P3 (High) Active time (in seconds) of the screw motor for the initial pellet loading. Active time (in seconds) of the heater without a fan. First power level of the fan. Set the duration (in minutes) for the fan to work along with the heater and its speed (in percents). Second power level of the fan. Set the duration (in minutes) for the fan to work along with the heater and its speed (in percents). Speed of the exhaust fan Duration (in seconds) of the initial burning process without feeding new pellets Speed of the fan during this process Speed of the exhaust fan during this process Time (in seconds) for the burner to work on first power level after ignition Time (in seconds) for the burner to work on second power level after ignition The highest power level of the burner. dt is the temperature difference between the set temperature for the boiler and its actual temperature. Feed is the time (in seconds, multiplied by 0,1) for loading pellets. If the number in column Feed is 50, it means 5 seconds. Cycle is the frequency (in seconds) of loading the pellets. Fan Speed is the fan's power level in User Manual ver 1.5 page 9 of 14

Intermediate cleaning Burning Shutdown P2 (Mid) P1 (Low) P0 (Suspend) Max Time @ Suspend Max Overheating Cycle Duration Fan Speed, col. 1 Fan Speed, col. 2 Fan Cleaner Motor P3 P2 P1 NPBC-V3M Monitoring Software percents. The 5 th column is the speed of the exhaust fan while the burner is working on this power level. Mid power level of the burner The lowest power level of the burner Power level for just maintaining the fire. Maximum time for maintaining the fire. Limit of overheating after which the burner turns off even if the Max Time @ Suspend hasn't run out yet. Active time of the fuel auger between two intermediate cleanings (in seconds) Duration of the cleaning process (in seconds) Speed of the main fan Speed of the exhaust fan If checked, the main fan will work in this procedures If checked, the FC output will be supplied during the intermediate cleaning procedures. For smooth extinction of the fire, set the time for the burner (in seconds) to work on its highest power level before switching to the lower one. Time for the burner (in seconds) to work on its middle power level before switching to the lowest one. Time for the burner (in seconds) to work on its lowest power before switching to Suspend mode. Hardware Burner Feeder Check, if your burner has a Burner Feeder Cleaner Motor Delay Thermostat NO Check, if your burner has a Cleaner Motor If checked, after every cleaning procedure, where the FC output has been supplied with power, there will be a delay before loading a new portion of pellets. The delay is equal to the active time of the FC output. Check for Normally Opened thermostat or uncheck for Normally Closed Add-ons CH pump Check, if you have a Central Heating installation pump Burner Feeder Duty DHW pump Thermostat Check, if you have a pump for the hot water installation Check, if you have a Thermostat The internal auger motor active time in percents, depending on the active time of the feed screw motor (Feed in section Power Modulation) + the additional constant time. User Manual ver 1.5 page 10 of 14

Photo Sensor Ignition If the level of illumination is higher than the first parameter in this setting for longer than the set time (second parameter) in seconds, then the ignition is successful. Extinction If the level of illumination is lower than the first parameter in this setting for longer than the set time (second parameter) in seconds, then the extinction is successful. CH Settings Min Temp The minimum required temperature for the Central Heating installation pump to turn on Hysteresis DHW Settings Set Temp Hysteresis The CH pump works for as long as the temperature of the water in the boiler is higher or equal to (Min Temp - Hysteresis) The minimum required temperature for the Hot Water installation pump to turn on. The DHW pump works for as long as the temperature in the boiler is higher or equal to (Set Temp Hysteresis) Language Language Choose between English, Spanish, Portuguese, Dutch or Bulgarian language for the controller's menus Set temperature Safety Settings Max Active Warning Alarm The maximum temperature that can be set on Tset on the main window. Put a check sign to activate this option (if the burner has a pt100 high temperature sensor, mounted in the vent) Set the value, required for a warning message, that the temperature of the exhaust gases in the vent is too high Set the critical value, when an alarm message turns off the burner, because of too high temperature of the exhaust gases in the vent If you have favorite settings, you can save them, by the button Save and if they change (because of future updating the software or else), you can load them, by the button Load. User Manual ver 1.5 page 11 of 14

7. Monitoring: 7.1. Fuel Consumption: The chart on the main window shows the fuel consumption for the last 24 hours or since it has been reset (if it was sooner). The newest information appears on the left side of the chart: The graphics' range depends on the parameter Feeder Capacity below it and on the parameter MAX_DUTY in the configuration file NPBC_Monitor.ini. The formula for the maximum value for the consumed pellets per hour that the graphics displays is: Fuel Consumption Max = Feeder Capacity * MAX_DUTY / 100 7.2. Status Chart: Click on the tab Status Chart on the top left side of the window, next to the tab Status. The following chart appears: The newest information about the current state of the burner is on the left side of the chart. User Manual ver 1.5 page 12 of 14

7.3. Console Click on the tab Console on the top left side of the window, next to the tab Status Chart. You will see the following information: 8. Export files: The monitoring software has an option to save records about the burner's state in text files. You can find them in the same directory where the monitoring program is. The file status.csv contains the information about the current day. The software adds a record in it on every 5 seconds. Every day, when the date changes, the monitoring software saves this file in the following format: status<yyyymmddhhmmss>.csv., where YYYYMMDDHHmmSS in the name are the date and the time when the last record in the file was made. This option is not activated by default. Follow these steps to activate it: 1. Open the file NPBC_Monitor.ini. 2. Find the line COM_PORT=COM1. Add the following two lines after it (as on the picture): CSV_EXPORT=1 CSV_EXPORT_ALL=1 3. Save the file NPBC_Monitor.ini and close it. User Manual ver 1.5 page 13 of 14

From now on, your software will start making records in the file status.csv. When you open the file, you will see a similar content: The parameters that you see on the picture are as follows: Computer's date and time Controller's hardware version Controller's software version Controller's date and time Burner's current work mode (Auto, Standby, Programme) Burner's status (cleaning, ignition, idle, etc.) Power level (if the burner is off, this parameter is skipped as on the picture above) Ignitor (on/off) CH pump (on/off) DHW pump (on/off) Set temperature of the boiler Boiler's current temperature Temperature of the water heater Thermostat (normal/stop) Level of illumination Total amount of used pellets in kg Errors (if any) User Manual ver 1.5 page 14 of 14