Spiratec R16C Automatic Steam Trap Monitor

Similar documents
Steam trap checking WHY WE NEED TO CHECK STEAM TRAPS METHODS OF CHECKING TRAPS ADVANTAGES AND DISADVANTAGES PRACTICAL DEMONSTRATION

Spiratec Steam trap monitoring

LC3000 Level Controller Installation and Maintenance Instructions

S and SF Inverted Bucket Steam Traps Installation and Maintenance Instructions

PA ma Loop Powered Level Preamplifier

3500 CONVENTIONAL FIRE ALARM CONTROL PANEL

Ball Float Steam Trap with Integral Spiratec Sensor and Flanged Connections

CRU 200 and 500 Series Condensate Recovery Unit Installation and Maintenance Instructions

LC2200 Level Controller Installation and Maintenance Instructions

3200 NON-ADDRESSABLE FIRE ALARM CONTROL PANEL

CRU-S Series Stainless Steel Condensate Recovery Unit

6100 SINGLE LOOP DIGITAL ADDRESSABLE FIRE ALARM CONTROL PANEL

OWNER S MANUAL. High-Wall Fan Coil Unit CONTENTS

Interactive Fire Control Panel IFS7002 four signal loops Instruction Manual

User Operation Manual

Interactive Fire Control Panel IFS7002 one signal loop Instruction Manual

User and Installation Instructions C6R/75, C6R/100, C6R/105, C6R/125, C6R/130, D6R/100, D6R/125, D5R/100, D5R/125, D3R/100

EasiHeat Mechanical Installation and Commissioning Instructions

SX65 and SX75. Electronic process controllers

Operation and Maintenance Manual Sondex All-Welded Heat Exchangers (SAW)

User s Information Guide R2A

Flash Condensing De-aerator Heads Installation and Maintenance Instructions

Universal control panel incorporating SIMS TM technology HTG Installation and Maintenance Instructions

Alarm Control Panel WIC-16Z4P WIC-5Z2P. User Instructions

Installation Manual Premier 412/816/832. Issue 10

Door Release Power Supply

Operating instructions

Version 1.03 January-2002 USER S MANUAL

MOOSE MPI 50 CONTROL PANNEL

User's Instructions. Alpha CB50

Operating and maintenance instructions for hobs

ICP-CC408 ICP-CC408 EN. Control Panel. User s Guide

SMARTELEC 2 ENERGY SAVING CONTROL INSTALLATION AND OPERATING MANUAL

IMS500 (Invetex Monitoring System Model 500)

User Manual FLOWMAX-90. for model. Condensing water heater 85,000 BTU. Installation, operating, commissioning and maintenance instructions.

Operating Guide. English Version 3.3

HILLS Series LED Code Pad User Manual

EDD61 & EDD91 Extractors

Algo-Tec 6500/6600 INTERACTIVE ADDRESSABLE FIRE CONTROL SYSTEM

USER MANUAL COMBINED FIRE & EXTINGUISHING CONTROL PANEL COMPLIES WITH BS EN PART 1 & EN54 PARTS 2 & 4

Owner's Manual TABLE OF CONTENTS

AlertMaxx2. Installation & Operating Manual. Ground Water (DMS-298) Pump Station High Level Alarm

Operating principle. Quinto

BX444-Mc Gas Detector

Universal Clamp Meter

2 INSTALLATION OPERATION TECHNICAL SPECIFICATIONS COMPONENTS FUNCTIONS REPAIR Series TS14/TDS14/PL138

IDM4 CARAVAN ALARM. Operating instructions

MODELS N150/300/675/900/1500/2500/2600 INSTALLATION, SERVICING AND MAINTENANCE INSTRUCTIONS

Premier Hazard STC Instructions

Duct and Rough Service Carbon Monoxide Sensor

CC880/LP880, SC8016. Operators Guide Solution-16, Solution-16 Safecom

R A D I O N I C S. READYKEY K2015A Alarm Event Manager. Installation Data Sheet. Description

User Instruction Manual

NookBox Installation Guide Keypad. Installation Guide. NookBox Keypad (P / E )

Operating manual and Log book for the range of 1,2,4 and 8 zone fire Control and Repeat panels

OWNER S MANUAL DLFCAB / DLFCHB / DLFDAB / DLFDHB High Wall Ductless System Sizes 09 36

TH100 Three in One Instant Hot Water Tap

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

Technical Bulletin. NUMBER 193 December 22, Steam Coil Change STEAM INSTALLATION REQUIREMENTS

TOUCHSTONE Dual Variable Speed System. Installation & Operating Manual with Troubleshooting and Configuration Guide

Archive. LC2200 Level Controller. 1. Safety information. 2. General product information. 3. Installation. 4. Setting up the controller

ICP-CC488 ICP-CC488 EN. Control Panel. User s Guide

Owner's Manual TABLE OF CONTENTS

WIRELESS WATER CONTROLLER. MC-503RC Installation and Operation Manual

THANK YOU FOR VOTING TEXECOM USER GUIDE. Security Control Panels

Fire Alarm Control Panel. System Maintenance and Log Book

Electronic steam boiler controls

READ CAREFULLY AND KEEP FOR FUTURE REFERENCE

CONGRATULATIONS ON CHOOSING THE WATERLOGIC 4 FIREWALL YOUR WATERLOGIC WATER DISPENSER

Model: 400E-5M. Bermad Hydraulically Controlled Anti-Columning Deluge Valve, with Easylock Manual Reset. Installation Operation Maintenance

CORNELL Emergency Response Systems

Model: Ei450. Instruction Manual

Alarm Controller Fire and CO

Rinnai. Rinnai GAS SPACE HEATERS. Convector 417 Unflued Room Heater CUSTOMER S OPERATING INFORMATION AND INSTALLATION INSTRUCTIONS

Installation & Operators Manual

Electric Digital Kettle

FT14 and FT14HC. SG Iron Ball Float Steam Traps (1" HC, 1¼", 1½" and 2")

Pie Warmer. Instruction manual. Model: GF454-A/GF455-A

205 Control Installation and Maintenance Instructions

EVP61/91/101/121. Extractor. Installation, use and maintenance.

User manual. Logano GC 124 II. Gas boiler

Fisher Scientific Isotemp Muffle Furnace 550 Series. Instruction Manual

Operating Instructions

Operating principle. Bolero XL (2008)

MFP14 Automatic pumps for condensate and other industrial fluids

40KMC KMQ

BlueHeat AirTop 2000 Heater

Food Steamer. Instruction manual. Model: CL205-A

Tomorrow s technology for today s security needs.

AVANT DGi. Thermal Electric Radiator. Operating and Installation Instructions. (Read these instructions carefully and retain for future reference)

Kalahari DECORATIVE FUEL EFFECT GAS FIRE

Three Phase Prepayment Meter Liberty-3P

Installation, Operating and Servicing Instructions

V-ZUG Ltd. Range hood DW-SE/DI-SE. Operating instructions

MFP14 Automatic pumps. for condensate and other industrial fluids

Protégé Eclipse LED Keypad User Manual PRT-KLES

Apollo Intelligent Auto Aligning Beam Detector. User Guide

Issue 4 10/10/11. Part Number: 48160

Operating instructions

FORMAT DGT HE. User instructions. Please read the Important Notice within this guide regarding your boiler warranty

Transcription:

0/ IM-P0- MI Issue Spiratec RC Automatic Steam Trap Monitor Operators Instructions RC 0. Introduction. Description. Description of keypad. Normal operation. Latching mode. Test unit mode. System failures Copyright IM-P0- MI Issue Printed in GB

The Spirax Sarco Spiratec RC automatic steam trap monitor consists of two main parts, the sensor chamber with sensor assembly (or steam trap with integral sensor) and the RC monitor. The RC can detect traps leaking steam and traps that have failed shut causing condensate to back up. To detect steam leaks, a standard SS sensor is installed in a sensor chamber or steam trap. To detect steam leaks and waterlogging, a WLS waterlogging sensor assembly is used. Passing or failed traps are shown clearly on the RC front panel.. Introduction Important note Refer to the Installation, Commissioning and Fault Finding manual for maintenance information. Warning Parts carrying this symbol protect against access to hazardous voltages and must only be removed or opened by suitably qualified personnel.. Description The RC automatic steam trap monitor constantly measures the conditions in the steam lines through the Spiratec sensors adjacent to steam traps. If a steam trap is operating correctly, condensate will collect and submerge the sensor. In the case of steam leakage, (i.e. the trap has failed open) then the steam will blast through the line, clearing the condensate and exposing the sensor. The RC monitor detects the presence of condensate by measuring the resistance between the SS sensor and the chamber or steam trap and gives a correct operation or a fail signal accordingly. The WLS steam leak and waterlogging sensor monitors steam leakage in the same way as above, but also has an inbuilt temperature sensor. In the case of the trap failing closed, the condensate which collects at the sensor will start to cool. The RC monitor detects the lower temperature and gives a failed signal. IM-P0- MI Issue

. Description of keypad RC 0 Fig. 0. STEAM LEAK TRAP FAIL LED S. This row of TRAP FAIL LED S indicates which trap is leaking steam.. WATERLOG TRAP FAIL LED S. This row of TRAP FAIL LED S indicates which trap is waterlogged.. TEST UNIT LED.. TEST UNIT KEY. Pressing and holding the TEST key will run a self test sequence (see section ).. LATCHING LED. This illuminates when the unit is in the Latching Mode. (see section ).. ACKNOWLEDGE KEY. Pressing the ACKNOWLEDGE key when the LATCHING LED is illuminated will acknowledge trap failures.. ENTER KEY. Not used during normal operation.. COMMUNICATIONS LED. Not currently used.. SECURE MODE LED. If an incorrect key sequence is pressed the SECURE MODE LED will flash for seconds. If the unit is in Secure Mode (see the Installation, Commissioning and Fault Finding Instructions ) and a protected key is pressed the SECURE MODE LED will illuminate and stay on for seconds. 0. STATUS INDICATOR. The segment LED decimal point will pulse slowly on and off during normal operation showing that the unit is functioning correctly.. TRAP FAILED NOW LED. When illuminated this LED indicates that one or more trap(s) is failing.. PASS LED. When illuminated this LED indicates that all traps are operating correctly. IM-P0- MI Issue

. Normal operation During normal operation the RC monitor will be displaying information as shown in the diagrams below. The STATUS INDICATOR will be pulsing on and off slowly. RC 0 The TEST UNIT LED PASS LED Fig. RC in normal operation with all traps operating correctly. The STATUS INDICATOR will be pulsing on and off slowly. One or more of the TRAP FAIL LED s will be illuminated RC 0 The TEST UNIT LED The TRAP FAILED NOW LED Fig. RC in normal operation with ONE OR MORE TRAPS FAILING. Note: See sections and for details of Latching Mode and Test Unit Mode. IM-P0- MI Issue

. Latching mode If the RC monitor has been set up in Latching Mode (see the Installation, Commissioning and Fault Finding Manual) then the units normal operation will be as shown in the diagrams below. The STATUS INDICATOR will be pulsing on and off slowly. RC 0 The TEST UNIT LED The LATCHING LED PASS LED Fig. RC in Latching Mode with all traps operating correctly. The STATUS INDICATOR will be pulsing on and off slowly. The TRAP FAIL LED(s) of the previously failed trap will now be flashing. RC 0 The TEST UNIT LED Pressing the ACKNOWLEDGE key will clear the flashing TRAP FAIL and LATCHING LED s. PASS LED Fig. RC in Latching Mode with one or more traps having previously failed and then returned to correct operation. Note: that the failure will be indicated as described in section, Fig. but the LATCHING LED would also be illuminated. IM-P0- MI Issue

. Test unit mode During normal operation the RC monitor may be tested by depressing and holding down the TEST UNIT KEY. RC 0. Ensure the STATUS INDICATOR is slowly flashing. This indicates that the unit is running and has not locked up.. The TEST UNIT LED is illuminated showing that the unit may be tested.. Press and hold the TEST UNIT KEY.. The RC monitor connects known test signals to the channel inputs and displays any fault with a flashing TRAP FAIL LED. Channels not selected will also flash. All other symbols will remain illuminated.. Testing will continue until the TEST UNIT KEY () is released. If a fault has been found refer to the Installation, Commissioning and Fault Finding Manual. IM-P0- MI Issue

Refer to the Installation, Commissioning and Fault Finding Manual. THE RETURN OF EQUIPMENT FOR REPAIR Please provide the following information with any equipment being returned:-. Your name, company name, address and telephone number, order number and invoice and return delivery address.. Description and serial number of equipment being returned.. Description of the fault or repair required.. System failures. If the equipment is being returned under warranty, please indicate: (i) Date of Purchase (ii) Original Order Number Return any items to your local Spirax Sarco branch. Please ensure all items are suitably packed for transit (preferably in the original cartons). IM-P0- MI Issue

IM-P0- MI Issue