Sprinkler Guards Model C Model D

Similar documents
Sprinkler Guards and Water Shields Model C Model D Model E

Model F1FR Series Quick Response Standard Spray

Model MBEC-14. Extended Coverage Ordinary & Extra Hazard Horizontal Sidewall Sprinklers for Metal Building Applications. Model MBEC-14 (SIN R6932)

Model F1 Residential Sprinklers for Design Density of.10 gpm/ft 2

Additional Bulletins applicable to all F1RES LL Sprinklers Wall Wetting - Bulletin 007 Design and Installation - Bulletin 140

Model F1 LO K 8.0 (115 metric) Standard Response Sprinklers

Model F3-80 Dry K8.0 (115 metric) Standard-Response, Standard Spray Sprinklers

Model JL-14 (SIN RA1812) K14.0 (200 metric) Early Suppression Fast Response Sprinkler

Residential Sprinkler For Sloped Ceilings

Model F3 Dry Sprinklers

Model F1 FR56 Recessed. Quick Response Standard Spray. Bulletin 014 Rev. G OJ

Model G5-56 Dry (SIN RA5114) K5.6 (80 metric) Concealed Dry Pendent Sprinkler

TECHNICAL DATA. Viking Technical Data may be found on. The Viking Corporation s Web site at.

Model DDX Deluge Valve

MicrofastHP EC/QREC FUSIBLE ELEMENT HSW HIGH PRESSURE SPRINKLER VK613 (K5.6) TECHNICAL DATA

standard response dry horizontal sidewall sprinklers

STANDARD RESPONSE DRY HORIZONTAL SIDEWALL SPRINKLERS TECHNICAL DATA

TECHNICAL DATA. 2. LISTINGS AND APPROVALS culus Listed: Category VNIV FM Approved: Class 2009 NYC Approved: MEA E, Volume 3

TECHNICAL DATA. Refer to Approval Chart 1 and Design Criteria for culus Listing requirements that must be followed.

TECHNICAL DATA. The Viking Corporation s Web site at Frame Casting: Brass UNS-C84400

quick response Sprinkler 105a October 25, 2010

standard response dry horizontal sidewall sprinklers

Microfast quick response Fusible element hsw sprinkler

HORIZON STANDARD RESPONSE FLUSH PENDENT SPRINKLER VK400 TECHNICAL DATA

standard response fusible link sidewall sprinkler VK112 (K5.6)

STANDARD RESPONSE DRY PENDENT STANDARD ORIFICE SPRINKLERS TECHNICAL DATA

micromatic standard response stainless steel sprinklers

standard response dry horizontal sidewall sprinklers

mirage standard response concealed pendent sprinkler vk492 (K5.6)

QUICK RESPONSE EXTENDED COVERAGE FUSIBLE ELEMENT PENDENT SPRINKLER VK601 (K5.6) TECHNICAL DATA

QUICK RESPONSE ELO PENDENT SPRINKLER VK377 (STORAGE-DENSITY/AREA) TECHNICAL DATA 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3.

QUICK RESPONSE FUSIBLE ELEMENT HSW SPRINKLERS VK308 AND HP VK320 (PART NOS AND 13955) TECHNICAL DATA

STANDARD/QUICK RESPONSE EXTENDED COVERAGE DRY HORIZONTAL SIDEWALL SPRINKLER TECHNICAL DATA

Standard Spray concealed horizontal sidewall sprinkler VK481

microfast and microfasthp quick response horizontal sidewall sprinklers (vk305 & vk319)

quick response ordinary hazard dry hsw sprinklers (8.0K) (VK275, VK277, & VK279)

Form No. F_ Rev 14.1 Page 1 of 6 TECHNICAL DATA

QUICK RESPONSE EXTENDED COVERAGE CONCEALED HSW SPRINKLER VK630 (K8.0) TECHNICAL DATA

micromatic standard sprinkler VK004 (K4.2) 3. technical data Page 1 of 6

TECHNICAL DATA STANDARD/QUICK RESPONSE EXTENDED COVERAGE LIGHT HAZARD ELO PENDENT SPRINKLER VK608

Refer to the specific sprinkler or spray nozzle technical data pages for sprinkler listings and approvals.

TECHNICAL DATA. MicrofastHP QUICK RESPONSE FUSIBLE ELEMENT PENDENT HIGH PRESSURE SPRINKLER VK318 (K5.6)

STANDARD/QR EXTENDED COVERAGE LIGHT HAZARD ELO FUSIBLE ELEMENT PENDENT SPRINKLER VK617 TECHNICAL DATA

standard response sprinklers (vk102 & vk202) 3. technical data Specifications: Minimum Operating Pressure: 7 psi (0.5 bar) Sprinkler 11j

qr fusible element sprinklers (part nos , 13959, 17535, and 17536) 3. technical data Sprinkler 42h March 14, 2013

mirage Quick response concealed pendent sprinkler vk464 (K8.0)

QUICK RESPONSE EXTENDED COVERAGE HORIZONTAL SIDEWALL SPRINKLER VK630 (K8.0) TECHNICAL DATA

quick response extended coverage horizontal sidewall sprinkler vk630 (k8.0)

TECHNICAL DATA. Page 1 of 6

MicrofastHP QUICK RESPONSE HORIZONTAL SIDEWALL HIGH PRESSURE SPRINKLER VK319 (K5.6) TECHNICAL DATA

Model RFC Series Residential Sprinklers Flat Cover Plate, Concealed Pendent Sprinkler. Product Features. Product Description

MicrofastHP EC/QREC FUSIBLE ELEMENT PENDENT HIGH PRESSURE SPRINKLER VK611 (K5.6) TECHNICAL DATA

TECHNICAL DATA 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA

Special Features: For Light Hazard Occupancies Only Designed for Corridor Applications 28 Maximum Width Spacing. 3. technical data

microfast and microfasthp quick response horizontal sidewall sprinklers (vk305 & vk319)

micromatic standard sprinkler VK003 (K2.8) 3. technical data Page 1 of 7

MIRAGE STANDARD AND QR CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) TECHNICAL DATA

STANDARD/QUICK RESPONSE EXTENDED COVERAGE PENDENT SPRINKLER VK602 TECHNICAL DATA

MIRAGE STANDARD AND QR CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) TECHNICAL DATA

TECHNICAL DATA. 2. LISTINGS AND APPROVALS NOTE: Viking Dry Vertical Sidewall Sprinklers are NOT listed or approved. Sprinkler 103a.

STANDARD RESPONSE FUSIBLE LINK PENDENT SPRINKLER VK008 (K4.2) TECHNICAL DATA 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA.

STANDARD/quick. Sprinkler 42o. August 8, 2011

TECHNICAL DATA. Viking Technical Data may be found on Maximum Working Pressure: 175 psi (12 Bar).

ec/qrec ordinary hazard upright and pendent sprinklers vk570 and vk572 (k14.0)

STANDARD/QUICK RESPONSE ECOH ELO FUSIBLE ELEMENT PENDENT SPRINKLER VK537 (K11.2) TECHNICAL DATA

micromatic Standard response Horizontal Sidewall sprinkler

standard response/qr extended coverage concealed pendent sprinklers vk614 & vk616

standard response elo upright and pendent sprinklers (storage-density/area)

standard response large orifice dry

QUICK RESPONSE DRY CONCEALED PENDENT SPRINKLER VK194 TECHNICAL DATA

microfast sr/qr extended coverage pendent sprinkler

MICROMATIC STANDARD RESPONSE PENDENT SPRINKLER VK102 (K5.6) TECHNICAL DATA 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA.

mirage Quick response extended coverage concealed pendent sprinklers (vk632 and vk634)

quick response sprinkler vk194 Sprinkler 104j January 1, 2011

C. All components of the systems described shall meet the requirements as stated herein and shall be approved by the Architect and Consultant.

Series TY-FRL 2.8, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description

freedom residential horizontal sidewall sprinkler Vk450 (k4.2)

DRY VERTICAL SIDEWALL SPRINKLERS TECHNICAL DATA

HORIZON QUICK RESPONSE FLUSH PENDENT SPRINKLERS TECHNICAL DATA

EC/QREC ORDINARY HAZARD PENDENT SPRINKLER VK572 (K14.0) TECHNICAL DATA

quick response extra-large orifice upright sprinkler vk531 (storage-density/area)

standard response/ quick response extended coverage

INSTITUTIONAL QUICK RESPONSE FLUSH HORIZONTAL SIDEWALL SPRINKLER VK412 (K5.6) TECHNICAL DATA

Page 1 of 7. Form No. F_ Rev Replaces Form No. F_ Rev 17.1 (added 205deg version)

mirage Quick response concealed pendent sprinkler vk465 (K4.2)

Page 1 of 7. Replaces Form No. F_ Rev 16.3 (Added 16X22 and 18X20 coverage areas)

standard response elo upright sprinkler

microfast quick response extended coverage hsw sprinkler vk606

Instructions for Installation, Operation, Care and Maintenance

MICROFAST AND MicrofastHP QUICK RESPONSE PENDENT SPRINKLERS TECHNICAL DATA

TECHNICAL DATA. Page 1 of 5

TECHNICAL DATA. Refer to Approval Chart 1 and UL Design Criteria for culus Listing requirements that must be followed.

INSTITUTIONAL QUICK RESPONSE FLUSH HORIZONTAL SIDEWALL SPRINKLER VK412 (K5.6) TECHNICAL DATA

standard/quick response sprinklers (vk302 & vk352) 3. technical data Specifications: Available since Sprinkler 41g May 1, 2009

TECHNICAL DATA OBSOLETE

micromatic Standard response Horizontal Sidewall sprinkler

HORIZON MIRAGE QUICK RESPONSE LARGE ORIFICE CONCEALED PENDENT SPRINKLER VK406 TECHNICAL DATA

MICROFAST QUICK RESPONSE PENDENT SPRINKLER VK302 (K5.6) TECHNICAL DATA

FREEDOM RESIDENTIAL HORIZONTAL SIDEWALL SPRINKLER VK479 (K3.0) TECHNICAL DATA

STANDARD/QUICK RESPONSE CONCEALED PENDENT SPRINKLER VK352-D (K8.0) TECHNICAL DATA

Transcription:

Bulletin 208 Rev. G Sprinkler Guards Model C Model D Bulletin 208 Rev. G Model C Sprinkler Guards Model C Series sprinkler guards are designed to be assembled onto installed sprinklers. They are constructed of heavy gauge wire welded to steel mounting plates and finished with zinc plating. Other finishes are available. Guards protect automatic sprinklers in locations where they are subject to physical damage. Refer to guard selection table for listing and approval information regarding specific sprinkler and guard combinations. All Model C guards are certified by FM Approvals. Models C-2 and C-3 also have culus Listings. Model C-1 Model C-1 guards are used with pendent, upright, horizontal sidewall and vertical sidewall sprinklers. Model C-2 Model C-2 guards are used with pendent dry sprinklers. Model C-3 Model C-3 guards have a water shield attached. When assembled to an upright sprinkler, the combination is for upright intermediate sprinkler applications. Model C-5 Model C-5 guards are supplied with a water shield and O-Ring which are assembled to the sprinkler before the sprinkler is installed. The guard is then installed to the sprinkler after it is installed in the fitting. Model D Sprinkler Guards The Model D Series sprinkler guards are supplied as kits to be assembled to the sprinkler at the job site before sprinkler installation. The kit consists of the guard, ½ and ¾ locknuts and a water shield when being used as an intermediate level sprinkler. The pendent intermediate has an O-Ring supplied. Each guard type is fabricated of heavy gauge wire welded to steel mounting plates and complies with the latest UL standards. Guards protect automatic sprinklers in locations where physical damage can occur. Model D Series guards are also available factory assembled on the sprinkler ready for immediate sprinkler/ guard installation. Consult factory for availability. Model D1 Sprinkler Guard Model D-1 Model D-1 guards can be assembled to pendent, upright and horizontal sidewall sprinklers. Model D-3 and D-6 Model D-3 and D-6 guards have a water shield attached and are assembled to upright sprinklers. The sprinkler guard assembly is for upright intermediate level sprinkler applications. Model D-4 and D-5 Model D-4 and D-5 guards are D-1 guards supplied with an original water shield which is threaded on (½ ) or passed over (¾ ) the sprinkler inlet thread. The combination forms a pendent intermediate level sprinkler. Guards and water shields are finished with zinc plating. Other finishes are available upon request. All Model D Guards are culus Listed. Refer to guard selection table for listing and approval information regarding specific sprinkler and guard combinations. Patents: USA Patent Number 5,893,418 Applies to Model D Series Guards Listings & Approvals 1. Listed by Underwriters Laboratories, Inc. and UL certified for Canada (culus) 2. Certified by FM Approvals 3. NYC MEA 258-93-E 4. Scientific Services Laboratories (SSL, Australia)* * For Models C1, C2, C3 guards. The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523

Model C-1 Guards Model C-2 Guards Model C-3 Guards Model C-5 Guards 2.

Model D-1 Guards Model D-3 Guards Model D-5 Guards Model D-4 Guards Model D-6 Guards 3.

Guards are approved to be used with sprinklers listed below. Guard Model (3) D-1 D-3 Sprinkler Model Application G, GFR, F1, F1FR, G, GFR, F1, F1FR, D-4 G, GFR, F1, F1FR D-5 G, F1, F1FR, F156, F1FR56 Sprinkler Type Pendent, Upright, HSW Orifice Sizes 3/8, 7/16, ½, 17/32 Upright Intermediate ½, 17/32 Pendent Intermediate (Large Shield) Pendent Intermediate (Small Shield) ½, 17/32 ½, 17/32 D-6 G XLO Upright Intermediate 0.64 R2921 C-1 G, F1, F1FR, Pendent, Upright, HSW, Vertical Sidewall, Upright & Pendent 3/8, ½, 17/32 C-2 F3, F3QR Pendent ½ C-3 C-5 G, GFR, F1, F1FR G, F1, F1FR Upright Intermediate ½, 17/32 Pendent Intermediate ½, 17/32 Approvals with SIN Number MEA (1), SSL (2) culus FM (3) R3611, R3613, R3615, R3612, R3621, R3623, R3625, R3622, R3111, R3113, R3115, R3117, R3121, R3123, R3125, R3127, R3635, R3131, R3133, R3135, R3137, R1711, R1713, R1715, R1712, R1721, R1723, R1725, R1722, R1735, R1011, R1013, R1015, R1016, R1017, R1021, R1023, R1025, R1026, R1027, R1231, R1233, R1235, R1236, R1237, RA1314, RA1414, R3625, R3622, R3125, R3127, R1725, R1722, R1025, R1026, R1027, R3115, R3117 R3615, R3612, R1715, R1712, R1015, R1016, R1017, RA1314, RA1414 R1616, R5314, R5714, R4216 R3625, R3622, R3125, R3127, R1725, R1722, R1025, R1026, R1027, RA1314, RA1414 R1011, R1015, R1016, R1017, R1021, R1025, R1026, R1027, R1235, R1285, R1712, R1715, R1721, R1725, R1735, R1785, R3612, R3615, R3622, R3625, R3635, R3685, RA1314, RA1414, RA1325, RA1425 R5314, R5714 R3625, R1725, R1025, R1027, RA1325, RA1425 R1015, R1017, R3615, R1715, R1712, R3612, (1) MEA approval on D-1, D-3, D-4, D-5, C-2, and C-3 (2) SSL approval on C-1, C-2, and C-3 (3) Model GFR does not have FM Approval. (4) Sprinkler guards are listed and approved only for use with specific sprinklers. The use of any other guards on these sprinklers may impede their operation or distribution and negate all approvals and warranties. 4.

Overall Cage Size: Models C-1, C-2, C-5 2 7 /8 (73mm) High X 2 3 /4 (70mm) Diameter Models C-3, D-3, D-6 2 3 /4 (70mm) High X 4 1 /2 (114mm) Diameter Models D-1, D-5 2 5 /8 (67mm) High X 3 (76mm) Diameter Installation Instructions Model C Guards With both cups unhooked, slightly spread open the guard. Insert steel plate into the installed sprinkler between the threads and the wrench flats. The steel plate tabs should face the sprinkler wrench flats and four contact points engage the sprinkler neck. For Model C-2, the steel plate fits into the groove in each wrench flat and the guard is located by the notch in both steel plates. Snap the upper locking clip into place, then close the near clip. The guard is now securely installed in place. If locking clip requires too much force to snap closed or open, slightly flex the wires on both sides of the clip and either close or open the clip. Model D Guards Model D1 Assemble the guard on the sprinklers using the following technique. With both cups unhooked, slightly spread open the guard. Insert steel plate into the installed sprinkler between the threads and the wrench flats. The steel plate tabs should face the sprinkler wrench flats and four contact points should engage the sprinkler neck. Snap the upper locking clip (steel plates) into place. Close the lower clip at the top of the guard and slide it down to the notch. The guard is more securely installed. Install the lock nut on to the NPT threads until the nut is securely against the guard. Model D-3, D4, D5 & D6 Before a sprinkler is installed into a fitting, assemble the guard on the sprinkler using the same technique described above for the Model C Guards. Then install a ½ or ¾ locking nut on to the NPT threads until the nut is tight against the guard. Each guard is supplied with both size of locking nuts. The assembly of sprinkler and guard is then wrenched into place using an adjustable wrench maximum size 8 and a jaw opening of 11/8 (for D- 1, D-3, D-4 or D-5) or an adjustable wrench maximum size 10 and a jaw opening of 15/16 (for D-6). Wrench must be placed over the guard. Do not use the wrench directly on the sprinkler wrench boss. The sprinkler wrench boss requires a special wrench. Finish Standard Finish Zinc with chromate dip. Other finishes, quoted on request. Ordering Information Guard Type (D-1,D-2 etc.) Finish (Standard or other) Sprinkler Inlet Thread Size, D-4 & D-5 Guards Only. Optional: Consult Factory for assembly on sprinkler. Specify Sprinkler: - Type. - Temperature Rating. - Finish. Wrench: Not supplied by Reliable 5.

Reliable...For Complete Protection Reliable offers a wide selection of sprinkler components. Following are some of the many precision-made Reliable products that guard life and property from fire around the clock. Automatic sprinklers Flush automatic sprinklers Recessed automatic sprinklers Concealed automatic sprinklers Adjustable automatic sprinklers Dry automatic sprinklers Intermediate level sprinklers Open sprinklers Spray nozzles Alarm valves Retarding chambers Dry pipe valves Accelerators for dry pipe valves Mechanical sprinkler alarms Electrical sprinkler alarm switches Water flow detectors Deluge valves Detector check valves Check valves Electrical system Sprinkler emergency cabinets Sprinkler wrenches Sprinkler escutcheons and guards Inspectors test connections Sight drains Ball drips and drum drips Control valve seals Air maintenance devices Air compressors Pressure gaugesidentification signs Fire department connection The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Productsmanufactured and distributed by Reliable have been protecting life and property for over 80 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured by The Reliable Automatic Sprinkler Co., Inc. (800) 431-1588 Sales Offices (800) 848-6051 Sales Fax (914) 829-2042 Corporate Offices www.reliablesprinkler.com Internet Address Recycled Paper Revision lines indicate updated or new data. EG. Printed in U.S.A 11/09 P/N 9999970152